IND560 industrial terminal
Simple weighing or fully-integrated automatic process control; either way, the IND560 is the right solution for your application. Choose from strain gauge or high-precision electromagnetic force restoration weighing technologies. Specify direct PLC or PC communication interfaces. Utilize digital I/O control. Combine these selections in a panel mount enclosure that is certified for use in hazardous environments, and the IND560 is the perfect match for just about any weighing applica-tion, in a variety of industries.
Complywith global regulations and standards. An IP69K rating makes the IND560 suitable for the harshest washdown conditions. Some models now certified safe for use in Divi-sion 2 or Zone 2/22 hazardous classified environments.
Weighwith confidence. Ultrafast A/D (>366 Hz) and TraxDSP™ digital filtering combine to deliver precise, repeatable, reliable mea-surements from milligrams to tons.
Controlautomatic material transfer applications without costly hardware and programming. An internal I/O option and built-in logic for filling and dosing provide process control without the need for a PLC.
Connectto existing systems, easily. Multiple con-nectivity options are available. The IND560 supports Analog Output, Allen-Bradley RIO, DeviceNet, PROFIBUS, EtherNet/IP and Modbus TCP. Take advantage of serial or Ethernet TCP/IP connectivity to plug into your network.
IND560 Industrial Weighing TerminalWeighing solution for challenging industrial environments
Features and Benefits• Enclosurealternativesassureinstallationflexibility.Stainless
steel Harsh model, designed to minimize cleaning time, is ideal for heavy washdown using pressurized cleaning solutions. Stainless steel Panel mount with flush front panel reduces con-tamination
• Configureterminalthroughaneasytonavigate,menu-driven,"Windows-like" set-up
• 15programmablesoftkeysprovidedirectaccesstofunctions• Large,brightVFDdisplayiseasytoreadandreduceseyefatigue• UsetheIND560asaremotedisplayforotherMETTLERTOLEDO
products• Security:Supports20usernameswithuniquepasswordsprovid-
ing setup and metrology security on four levels• TraxDSP™:Tunabledigitalfilteringsupressesenvironmental
effects on weighing accuracy• MemoryTablesstoreupto25fixedtarerecords,eachwithaccu-
mulation, or 25 target records with tolerances• Forcheckweighingorfilling,selectOver/UndermodeorMaterial
Transfer mode to access built in logic for further customization of your application
• Comparatorsfeaturepermitsdefinitionoffivesimpletargetsusing multiple sources. Assignable digital outputs are available
• UseSmartTrac™tocustomizethedisplayofprocessinforma-tion. Multiple options control the amount of information shown on-screen.
• EnabletheRatefeaturetoshow'weightvs.time'dataontheter-minal display, or further use as a source for Comparators or the Analog Output
• Upto20programmableoperatorpromptsgiveon-screencom-mandsdirectingoperatorsthroughsequentialsteps,reducingopportunity for error. Messages can also be written to the termi-nal display from a remote location
• OptionalUSBQWERTYkeyboardinterfacepermitsfastandeasydata entry
• ApplicationModulespermittheadditionoffeatureswhereneeded. Select from Fill-560 for enhanced filling and dosing, Drive-560 for simple in and out vehicle transactions, COM-560 for communication with legacy protocols or for customized CTPZ type commands, and Dyn-560 for true in-motion package weighing
www.mt.com/IND5xxFor more information
SERVICEINTERNET
Subject to technical changes©01/2012Mettler-Toledo International, LLCINDB0004.11E
QualitycertificateISO9001EnvironmentcertificateISO14001Internet:http://www.mt.comWorldwide service
Enclosure dimensions (L x W x D) Panelmount:265x160x91.8mm(10.4x6.3x3.6in.)Harshmodel:265x160x170.3mm(10.4x6.3x6.7in.)
Enclosure construction Harshmodel:Stainlesssteel,IP69KcertifiedPanelmountmodel:Stainlesssteelfrontpanel,certifiedtype4x/12protection.Division2,Zone2/22approvalsrequireuseofsuitableenclosure
Shipping weight 3.5kg(7.7lbs)
Power Universalpowersupply,87to264VACat49to61Hz,600mAconsumption
Operating environment -10°C to +40°C(14°Fto104°F),10%to95%relativehumidity,non-condensing
Display Vacuumfluorescent,21mmweightdisplay,graphiccapabilities;128x64dotmatrix.Maximumresolution100,000divisions
Keypad Clear,Tare,Print,Zero,navigationkeyset,fullnumericalkeypad,5physicalsoftkeys(15totalassignments,alphanumericcapability
Supported scale types Analog:10VDCexcitation,powerupto8350Ωloadcells,2or3mV/VIDNet:Interfaceforcurrenthigh-precisionK-bases.OptionalpowersupplyforearlierK-basemodels. Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance
Calibration options Traditional calibration with separate zero and span captures, 5 step linearizationCalFree™electroniccalibration,requiresnotestweightsProgrammablecalibrationsequence(upto20steps)andconfigurablecalibrationexpirationalertsandactions
Connectivity Singleserialportstandard(COM1:RS-232/422/485);optional10Base-TEthernetTCP/IPportwithtwoadditionalserialports(COM2:RS-232;COM3:RS-232/422/485)oroptional10Base-TEthernetTCP/IPportwithUSBMasterandsingleserialCOM3(RS-232/422/485)oroptional10Base-T EthernetTCP/IPportwithUSBMasterandoneadditionalserialport(COM3:RS-232/422/485) Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance
Interface options PLC(selectoneoption):Allen-Bradley® Remote I/O, PROFIBUS®DP,DeviceNet™,AnalogOutput(4-20mAor0-10VDC),EtherNet/IP™,Modbus TCPLocalandRemoteI/O(relay-based):ARM100DigitalInput/OutputModule− Extends the discrete input and output control of the IND560 to remote locations,maximumof12inputsand18outputs.Warning!Relay-basedI/OoptionsarenotapprovedforinstallationinhazardousareasA100AnalogOutputModule:convertsMETTLERTOLEDOContinuousorSICSserialsignaltoa4/20mAsignal Warning! Division2,Zone2/22installationlimitationsexist;refertocontroldrawing72186884Rorcontactsupportforassistance
Agency Approvals Weights and Measures
USA ClassII100,000d,ClassIII/IIIL10,000d,CoC05-057A2
Canada ClassII100,000d,ClassIII10,000d,ClassIIIHD20,000d,AM-5593
Europe ClassIIdeterminedbyplatform,ClassIII10,000e,ClassIIII1000e.IncludesAlibiMemory,TC6812rev8MID −Catchweighing-T10230;Gravimetricfilling-T10231
Australia ClassIII7500eor3x3000emultiplerange,NMIS483
HazardousArea(wheninstalledperMETTLERTOLEDOcontroldrawing72186884R)
Panel,USA/Canada(UL):ClassIDivision2GPA-D;Class2Division2GPF,G:ClassIII;ClassI,Zone2GPIIC
Panel,Europe(ATEX):II3GEExnL[nL]IIBT4-10°C ≤ Ta ≤ +40°C.II3DT85°C-10°C ≤ Ta ≤ +40°C IP6X
Harsh,USA/Canada(UL):ClassIDivision2GPA-D;ClassIIDivision2GPF,G:ClassIII;ClassIZone2GPIIC
Harsh,Europe(ATEX*): II3GEExnL[nL]IIBT4-10°C ≤ Ta ≤ +40°C.II3DT85°C-10°C ≤ Ta ≤ +40°C IP69K* Harsh/IDNet model not included in Category 3 approvals
METTLERTOLEDOisuniquelyqualifiedtoprovidethe installation, calibration and maintenance services essential to ensuring accuracy, optimiz-inguptimeandprolongingequipmentlife.Ourservice representatives will be there at the right time, with the right parts, the right tools and the right skills to meet your needs.
Essential Services for Dependable Performance
IND560 TerminalTechnical Specifications