vert-x 32e - 24v / canopen, redundant - · pdf filevert-x 32e - 24v / canopen, redundant...
TRANSCRIPT
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Sensor principle MH-C2
Electrical data
Measuring range ° 0 ... 360
Indep. linearity (without misalignment) % of meas. range ±0.3
Indep. linearity (with misalignment) % of meas. range ±1
Max. hysteresis ° 0.1
Resolution bit 16
Max. repeatability ° 0.1
Sample rate kHz 0.5
Max. temperature coefficient of the output signal ppm/°K 25
MTTFd / MTBF years 135 / 135
Power supply voltage VDC 8 ... 35
Current consumption without bus load (typ.), per channel mA 30
Reverse polarity protection of power supply yes
Electrical connection Round cable
Cross section of single wires mm2 0.34 (AWG 22)
Bus interface ISO/DIS 11898-2
CANopen communication according to CiA Standard DS-301 Rev. 4.02
Device profile DS-406, Rev. 3.1, Encoder class C2
Default Node-ID's 16 & 17 (programmable 1 ... 127)
Default bitrate kBit/s 125
Mechanical data
Mechanical range ° 360 (continuous)
Protection class IP68
Min. life movements no limitation
Operating & storage temperature °C -40 ... +85
IEC 68-2-6 Vibration (Amax = 0.75mm, f = 5 … 2000 Hz) g 20
IEC 68-2-27 Shock g 50
Standards
EN 55022 classe B, Emission radiated (30... 230 MHz) dB(µV/m) max. 30
EN 55022 classe B, Emission radiated (230...1000MHz) dB(µV/m) max. 37
EN 61000-4-2, ESD (contact discharge / air discharge) kV ±4 / ±8
EN 61000-4-3, Immission HF radiated (80...2700 MHz) V/m 100
EN 61000-4-4, Burst (on all lines) kV ±3
EN 61000-4-5, Surge (lines to ground) kV ±1
EN 61000-4-6, Immission HF conducted (0.15...80 MHz) Vemk 12
EN 61000-4-8, Immission magnetic field (50 Hz) A/m 300
IEC 60393-1 Insulation resistance (500VDC, 1bar, 2s) GOhm 20
IEC 60393-1 Dielectric strength (VAC, 50Hz, 1min, 1bar) kV 1
CANopen conformance certified by CiA Certificate-#: CiA201003-301V402/20-0116
Vert-X 32E - 24V / CANopen, redundant
Applications• Forklifter• Platformer• Agriculturalmachine
Features
• CiAapproved
• Non-contactingmeasuring method • Verylonglife• Highaccuracyof measurement• Applicationsunderadverse ambient conditions possible (humidity, dampness, oil dust, vibrations etc.)
CiA201003-301V402/20-0116
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E - 24V / CANopen, redundant
Ordering code
Options (on request)
Length of cable02 Standard 1.0m06 Optional 3.0m10 Optional 5.0m99 Optional Special length
Electrical connection6 Optional Round cable 6pole8 Standard Round cable 4poleC Standard 2x Round cable 4pole9 Optional Special cable
2Vert-X 3 2 E 6 8 3 6 1 3 8 C 0
Electrical angle36 Standard Electrical angle 360°
Sensor principle 8 MH-C2
Mechanical version32E5 Optional Magnetic actuator type 532E6 Standard Magnetic actuator type 632E7 Optional Magnetic actuator type 732E8 Optional Magnetic actuator type 832E9 Optional Special magnetic actuator
b
Mounting hole b Standard Through-hole ø 4.4mm with counterbore ø 8mm / label sided Optional Through-hole ø 4.4mm with counterbore ø 8mm / magnetic actuator sidee Optional Through-hole ø 4.4mm with counterbore 90° on both sides
Power supply voltage 24VDC Standard 1
Output signal CANopen Encoder Profile 406 (C2) Standard 3
MH-C2
Custom magnetic actuator X
Custom cable X
CAN integrated bus termination resistor (120Ω) / RCAN X
Custom bitrate (10 ; 20 ; 50 ; 100 ; 250 ; 500 ; 800 ; 1000 kBit/s) X
CAN characteristics Redundant 2-Bus / CAN-High; CAN-Low; RCAN Optional 7 Redundant 2-Bus / CAN-High; CAN-Low Standard 8 Redundant 1-Bus / CAN-High-In; Optional A CAN-High-Out; CAN-Low-In; CAN-Low-Out Redundant 1-Bus / CAN-High; CAN-Low; RCAN Optional B Redundant 1-Bus / CAN-High; CAN-Low Standard C Special version Optional 9
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E5redundant
Accessoires (incl.)None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorsee mounting information
Vert-X 32E5b836 13x xxx 1)
Vert-X 32E5d836 13x xxx 2)
Vert-X 32E5e836 13x xxx 3)
1)
2)
3)
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E6redundant
Accessoires (incl.)None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorsee mounting information
Vert-X 32E6b836 13x xxx 1)
Vert-X 32E6d836 13x xxx 2)
Vert-X 32E6e836 13x xxx 3)
1)
2)
3)
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E7redundant
Accessoires (incl.)None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorsee mounting information
Vert-X 32E7b836 13x xxx 1)
Vert-X 32E7d836 13x xxx 2)
Vert-X 32E7e836 13x xxx 3)
1)
2)
3)
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E8redundant
Accessoires (incl.)None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorsee mounting information
Vert-X 32E8b836 13x xxx 1)
Vert-X 32E8d836 13x xxx 2)
Vert-X 32E8e836 13x xxx 3)
1)
2)
3)
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E5redundant
Mounting information Working position (Z)MH-C2 17.50mm Max. permitted misalign-ment of the magneticactuatordx ±2.00mmdy ±2.00mmdz ±1.20mm
Vert-X 32E6redundant
Mounting information Working position (Z)MH-C2 7.40mm Max. permitted misalign-ment of the magneticactuatordx ±2.00mmdy ±2.00mmdz ±0.80mm
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E7redundant
Mounting information Working position (Z)MH-C2 15.90mm Max. permitted misalign-ment of the magneticactuatordx ±3.00mmdy ±3.00mmdz ±1.80mm
Vert-X 32E8redundant
Mounting information Working position (Z)MH-C2 13.80mm Max. permitted misalign-ment of the magneticactuatordx ±3.00mmdy ±3.00mmdz ±1.60mm
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 29.08.14
Vert-X 32E - 24V / CANopenCertificates