vertical control joint self-furred laththickness allowed by c926 over the 2 narrower block....
TRANSCRIPT
VERTICAL CONTROL JOINT
ALWAYS CONTINUOUS
SELF-FURRED LATH
EMBED AND SEAL CJ ENDS AT
INTERSECTIONS, BUTT JOINTS
AND CORNERS OF ALL CJ
WATER RESISTANT BARRIER,
CONTINUOUS BEHIND CONTROL JOINTS
HORIZONTAL CONTROL JOINT,
BUTT TO VERTICAL CONTROL JOINT
CUT FLANGES OF CONTROL JOINT SO AS TO
CREATE A TIGHT FIT WITH A UNIFORM DEPTH
INSIDE AND OUTSIDE CORNERS SHALL BE
MITERED AND JOINTS EMBEDDED IN SEALANT
NOTE
1. AT TIME OF INSTALLATION, EMBED ALL BUTT JOINTS, ENDS,
ANGLES, CORNERS, AND INTERSECTIONS IN SEALANT.
2. LATH SHALL BE DISCONTINUOUS BEHIND CONTROL JOINTS.
3. COORDINATE THE DEPTH OF THE CONTROL GROUND
FLANGE WITH THAT OF THE WEEP ACCESSORY INTO
WHICH THE CONTROL JOINT TERMINATES BASED UPON
THE SEQUENCING OF THE LATH AND CONTROL JOINT
INSTALLATION SO AS TO ENSURE THAT THE GROUNDS OF
EACH ACCESSORY ALIGN IN PLANE.
CONTROL JOINT INTERSECTION SEALANT DETAIL
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
DTL 1
7
1
2
"
7
5
8
"
7
3
4
"
7
1
2
"
7
5
8
"
7
3
4
"
RESULTING STUCCO THICKNESS 1/2"
MORTAR JOINT STRUCK FLUSH WITH
BLOCK FACE
RESULTING STUCCO THICKNESS 5/8"
MORTAR JOINT STRUCK FLUSH WITH
BLOCK FACE
RESULTING STUCCO THICKNESS 3/8"
ASTM C90 COMPLIANT CONCRETE
MASONRY UNITS
STUCCO THICKNESS VARIATIONS DUE
TO ALLOWABLE CMU SIZE TOLERANCES
NOTES
1. IN EITHER CASE STUCCO CANNOT BE APPLIED TO CODE/STANDARD
COMPLIANT THICKNESS WITHOUT SOME TOLERANCE.
2. IN ORDER TO MAINTAIN THE REQUIRED 1/2" NOMINAL THICKNESS AND KEEP
THE FINISH COAT PLANE TRUE AND PLUMB, THE STUCCO MAY EXCEED THE
THICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK.
3. RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF
TABLE 4 OF ASTM C926 TO BE EVALUATED BY A DESIGN PROFESSIONAL
FOR AUGMENTATION REQUIREMENTS OF SECTION 6.2 OF ASTM C926.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 2
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
7
8
" STUCCO SYSTEM
7
8
" STUCCO SYSTEM
5
8
" RESULTING
STUCCO THICKNESS
1-
1
8
" RESULTING
STUCCO THICKNESS
WOOD FRAMING
SHEATHING
TRUE VERTICAL TRUE VERTICAL
STUCCO THICKNESS VARIATIONS DUE TO FRAMING
NOTE
1. IN EITHER CASE STUCCO CANNOT BE APPLIED TO CODE/ STANDARD COMPLIANT
THICKNESS WITHOUT SOME TOLERANCE.
2. IN ORDER TO MAINTAIN THE REQUIRED 7/8" THICKNESS AND KEEP THE FINISH
COAT PLANE TRUE AND PLUMB, THE STUCCO WOULD HAVE TO EXCEED THE
THICKNESS ALLOWED BY C926, EITHER IN THE MIDDLE OR ON THE ENDS
RESPECTIVELY.
3. RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4
OF ASTM C926 TO BE EVALUATED BY A DESIGN PROFESSIONAL FOR CORRECTIVE
OPTIONS.
EXTERIOR EXTERIOR
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 3
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
2 LAYERS OF WRB AT BOTTOM
OF BEAM AND/OR STRIP OF SAF.
(SIM. TO FLASHING WINDOW)
W
A
L
L
S
H
E
A
T
H
I
N
G
PENETRATING
BEAM
1-PIECE OR 2-PIECE
WATERTIGHT COLLAR
MAINTAIN MIN
1
4
" GAP
BETWEEN BEAM AND COLLAR
2 LAYERS
TOP WRBs (AND/OR
STRIP OF SAF AND
WRB) OVER COLLAR
INSTALL WRBs OVER
TOP FLASHING FLANGE
BOTTOM OF COLLAR
OVER WRB
LATH
INSTALL BACKER ROD AND
SEALANT CONTINUOUS
AROUND ALL SIDES
3
8
" GAP FOR BACKER ROD
AND SEALANT
2
"
M
I
N
.
L
A
P
O
F
W
R
B
SEQUENCE FLASHING - 1-PIECE COLLAR
(2-PIECE, SIM.)
COLLAR FLASHING SEQUENCE
1. WRB LAYERS AT BOTTOM OF BEAM 2. INSERT FLASHING COLLAR INTO BEAM 3. INSTALLMENT OF WRBs
OVER TOP FLASHING FLANGE
4. BACKER ROD AND SEALANT 5. LATH AND WRB
"BEST PRACTICE" FIRST STEP
SAF OR FLUID-APPLIED
BARRIER
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 4
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
3 COAT STUCCO SYSTEM
DIRECT APPLIED STUCCO
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING, 'OSB', PLYWOOD,
DENSGLASS
LAPS IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATION
SAF (RECOMMENDED)
3
1
2
" FLANGE
SILL SEAL
PLASTER STOP
DRIP SCREED. THE LEADING EDGE
OF THE WEEP SCREED SHALL NOT
BE PAINTED OR SEALED.
1
8
" S
HE
AT
HIN
G G
AP
1
4
" M
IN
.
1" M
AX
.
CONTINUOUS BACKER ROD AND
SEALANT REQUIRED. COORDINATE
ACCESSORY DIMENSIONS AND
ANGLE TO ENABLE BACKER ROD
AND SEALANT MAINTENANCE.
FRAME TO MASONRY TRANSITION EXPANSION
WITH DRIP SCREED DETAIL
FASTENERS WITHIN
1
2
" OF TOP OF WEEP
SCREED INTO VERTICAL FRAMING
MEMBERS ABOVE TRANSITION
1
4
" LATH GAP MIN.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 5
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CMU
DOUBLE BACK
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
LAPS IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATION
THE LEADING EDGE OF THE
WEEP SCREED SHALL NOT BE
PAINTED OR SEALED.
SAF (RECOMMENDED)
MID-WALL WEEP SCREED
NOTES
1. SELF ADHERED FLASHING SHOULD NOT EXTEND PAST THE
MID-WAY POINT OF THE UPPER ROW OF PERFORATIONS IN
THE LOWER FLANGE OF THE SCREED TO ENSURE BOND OF
THE PLASTER TO THE CMU.
2. STAGGER JOINTS (HORIZONTAL AND VERTICAL) IN WATER
RESISTIVE BARRIER AND FOR LATH.
3. APPLIED TEXTURE IS NOT A PLASTER COAT AND IS NOT
COUNTED IN THICKNESS MEASUREMENT.
SEQUENCING OF STUCCO COATS DETAIL
1
8
" S
HE
AT
HIN
G G
AP
1
4
" M
IN
.
1" M
AX
.
LATH FASTENERS TO BE
PLACED ABOVE THE
CENTER OF SILL PLATE
FASTENERS WITHIN
1
2
" OF TOP OF
WEEP SCREED INTO VERTICAL FRAMING
MEMBERS ABOVE TRANSITION
SILL SEAL
1
4
" LATH GAP MIN.
AN UNPAINTED/SEALED NARROW KERF
CUT HERE WILL FACILITATE DRAINAGE
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 6
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
LATH
CMU
3 COAT STUCCO SYSTEM
WRB-DRAINAGE PLANE
SHEATHING
LAPS IN ACCORDANCE
WITH MANUFACTURERS
SPECIFICATION
WRB-BOND BREAK
SAF (RECOMMENDED)
MID-WALL WEEP SCREED
NOTES
1. SELF ADHERED FLASHING SHOULD NOT EXTEND PAST
THE MID-WAY POINT OF THE UPPER ROW OF
PERFORATIONS IN THE LOWER FLANGE OF THE SCREED
TO ENSURE BOND OF THE PLASTER TO THE CMU.
2. STAGGER JOINTS (HORIZONTAL AND VERTICAL) IN
WATER RESISTIVE BARRIER AND FOR LATH.
TRANSITION OR MID-WALL WEEP SCREED DETAIL
THE LEADING EDGE OF THE
WEEP SCREED SHALL NOT BE
PAINTED OR SEALED.
1
8
" S
HE
AT
HIN
G G
AP
1
4
" M
IN
.
1" M
AX
.
LATH FASTENERS TO BE
PLACED ABOVE THE
CENTER OF SILL PLATE
FASTENERS WITHIN
1
2
" OF TOP OF
WEEP SCREED INTO VERTICAL FRAMING
MEMBERS ABOVE TRANSITION
1
4
" LATH GAP MIN.
AN UNPAINTED/SEALED NARROW KERF
CUT HERE WILL FACILITATE DRAINAGE
SILL SEAL
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 7
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
HOLES ARE NOT FOR DRAINAGE.
THEY ASSIST IN KEYING THE
ACCESSORY TO THE STUCCO.
SCREED
6"
MIN
.
BACK OF SCREED CAN BE SEALED FOR
AIR INFILTRATION, INSECT INTRUSION
AND WATER PENETRATION WHERE
SUSCEPTIBLE TO WIND EXPOSURE
LATH
SLAB ON FOUNDATION
3 COAT STUCCO SYSTEM
WRB-DRAINAGE PLANE
LAP OVER TOP OF SCREED
SOLID SHEATHING FLUSH
WITH FOUNDATION EDGE
WRB-BOND BREAK
NO FASTENERS
BELOW TRANSITION
FINAL LANDSCAPE
RECOMMENDED STRIP OF
SAF OVER SCREED FOR
WATER RESISTANCE
1/8" MIN. GAP BELOW WOOD-BASED
SHEATHING FOR CAPILLARY BREAK
OR EXPANSION
PROVIDE CONTINUOUS WEEP.
THE LEADING EDGE OF THE
WEEP SCREED SHALL NOT BE
PAINTED OR SEALED.
GRADE
FOUNDATION WEEP SCREED DETAIL
NOTES
1. HEIGHT ABOVE GRADE IS GOVERNED BY LOCAL
BUILDING CODE OR MANUFACTURER’S
INSTRUCTIONS. CHECK WITH YOUR LOCAL CODE
JURISDICTION FOR CLEAR SPACE REQUIREMENTS.
2. LAP SCREED OVER SLAB/SILL JOINT A MIN. OF 1/4"
AND A MAXIMUM OF 1" TO PREVENT WATER
INTRUSION UNDER SILL.
3. USE A BEAD OF SEALANT BETWEEN SHEATHING
BASE AND CONCRETE OR A STRIP OF SAF OVER
THE JUNCTURE BEHIND THE SCREED TO PREVENT
WATER OR INSECT INTRUSION.
4. SCREEDS FOR USE BEHIND LATH ARE REQUIRED
TO HAVE A 3-1/2" ATTACHMENT FLANGE.
FASTENERS SHOULD BE PLACED IN THE TOP 1/2"
OF THE SCREED INTO VERTICAL FRAMING
MEMBERS.
5. BACK OF SCREED CAN BE SEALED FOR AIR
INFILTRATION AND WATER PENETRATION WHERE
SUSCEPTIBLE TO WIND EXPOSURE.
6. FOUNDATION WEEP SCREEDS ARE NEITHER
REQUIRED NOR FUNCTIONAL ON CMU WALLS
WHERE STUCCO IS DIRECTLY APPLIED.
THE LEADING EDGE OF THE
WEEP SCREED SHALL NOT BE
PAINTED OR SEALED.
1
4
" M
IN
.
1" M
AX
.
LATH FASTENERS TO BE PLACED
ABOVE THE CENTER OF SILL PLATE
FASTENERS WITHIN
1
2
" OF TOP OF
WEEP SCREED INTO VERTICAL FRAMING
MEMBERS ABOVE TRANSITION
1
4
" LATH GAP MIN.
AN UNPAINTED/SEALED NARROW KERF
CUT HERE WILL FACILITATE DRAINAGE
SLAB ON FOUNDATION
1
8
" S
HE
AT
HIN
G G
AP
SILL SEAL
SILL SEAL
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 8
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
3 COAT STUCCO SYSTEM
SHEATHING, 'OSB',
PLYWOOD, DENSGLASS
STRIP OF SAF
3
1
2
" FLANGE
PLASTER STOP
DRIP SCREED
THIS GAP IS A RESULT OF NATURAL
SHRINKAGE. PROVIDE CONTINUOUS
WEEP. THE LEADING EDGE OF THE WEEP
SHALL NOT BE PAINTED OR SEALED.
CONTINUOUS BACKER ROD
& SEALANT REQUIRED
1
4
" G
AP
1
4
" LA
TH
GA
P M
IN
.
WRAP DP WRB ONTO THE VERTICAL
SURFACE TO TOP OF FLANGE AS AN AIR
BARRIER. DP WRB SHOULD EXTEND TO
THE TOP OF THE ACCESSORY FLANGE
TO BE TRIMMED OFF AT THAT POINT
VERTICAL EXTERIOR
CEILING (SOFFIT)
SOFFIT TO EXTERIOR FACE DRIP DETAIL
NOTES:
1. A DESIGNER PROFESSIONAL SHALL DETAIL THE CONDITION WHERE WRBs
ARE EMPLOYED ON HORIZONTAL SURFACES.
2. LATH SHALL BE TERMINATED A MINIMUM 1/4 INCH ABOVE THE GROUND
FLANGE OF THE DRIP SCREED TO RESIST CORROSION.
FASTENERS WITHIN
1
2
" OF TOP OF
WEEP SCREED INTO VERTICAL FRAMING
MEMBERS ABOVE TRANSITION
CONTINUOUS BACKER ROD
& SEALANT REQUIRED
PLASTER STOP
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 9
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
STUD
WRB-DRAINAGE PLANE
WRAP
WRB-BOND BREAK
(PAPER)
SF LATH
1"
1
8
" S
HE
AT
HIN
G G
AP
3 COAT STUCCO SYSTEM
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING, 'OSB', PLYWOOD,
DENSGLASS
SAF (RECOMMENDED)
CONTINUOUS BACKER ROD AND SEALANT
REQUIRED. COORDINATE ACCESSORY
DIMENSIONS AND ANGLE TO ENABLE
BACKER ROD AND SEALANT MAINTENANCE
7
8
" PLASTIC STOP OR
BACKER ROD
Z FLASHING SHOULD
COVER GAP IN SHEATHING
(1" GROUND, 31/2" FLANGE)
SILL PLATE
FLOORING
TOP PLATE
FRAME TO FRAME TRANSITION EXPANSION
WITH DRIP SCREED DETAIL
NOTES:
1. THE DRAINAGE PLANE WRB SHALL BE
PLACED FIRST SO THAT THEY EXTEND
BETWEEN 2 AND 3 INCHES ABOVE THE
GROUND FLANGE OF THE DRIP SCREED.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 10
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
STUCCO SYSTEM
CIP WALL (SHEAR WALL, ETC.)
SEALANT ON BOND BREAKER
BACKER ROD AND SEALANT
PLASTERSTOP
CASING BEAD
DIRECT APPLIED ON
CMU / SHEAR WALL DETAIL
NOTES:
1. THIS OPTION ALLOWS FOR DEVIATIONS IN
VERTICAL ALIGNMENT BETWEEN CIP AND CMU
AND DIFFERENTIAL MOVEMENT BETWEEN TWO
SEPARATE STRUCTURAL ELEMENTS. THERE
SHOULD BE A MASONRY CONTROL JOINT AT
THIS LOCATION.
2. DOUBLE-BACK OR DOUBLE-UP COAT. THE
BROWN COAT PLASTER APPLIED TO THE
SCRATCH COAT PLASTER BEFORE THE
SCRATCH COAT PLASTER HAS SET.
SURFACE PREPARATION NOTES:
1. SPECIFY BLOCK SURFACE
CHARACTERISTICS - COARSE.
2. TEXTURE IS NOT A COAT.
A
DETAIL 'A' (OPTIONAL )
EXPANSION JOINT
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 11
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
TEXTURE
BROWN COAT
SCRATCH COAT
LATH (SEE NOTES)
WRB-BOND BREAK
WRB-DRAINAGE PLANE
CONT. SUBSTRATE SHEATHING
6" STRIP SAF (NOT REQD.)
1/2 INCH CORROSION-RESISTANT
SCREWS.
CJ CAN BE APPLIED BEFORE OR
AFTER LATH, (CJ OVER LATH MAY
NEED TO REDUCE GROUND FOR
UNIFORM DEPTH)
TIE CJ TO LATH
FINISH COAT
2. VERTICAL CONTROL JOINT
3. HORIZONTAL AND VERTICAL
CONTROL JOINTS
1. HORIZONTAL CONTROL JOINT
NOTES
A. DISCONTINUOUS LATH BEHIND CJ
PER ASTM C1063.
B. DISCONTINUOUS LATH OVER CJ BY
SOME LATHERS.
C. NOTE: METHOD A OR B ABOVE WILL
AFFECT THE DEPTH OF THE GROUND
OF THE CONTROL JOINT
ACCESSORY.
CONSIDERATIONS
1. CJ IS INTENDED TO PROVIDE
LOCATION FOR STUCCO CRACKS TO
OCCUR DURING THE CURING PERIOD.
2. SUBSTRATE MOVEMENT IS
EXPECTED TO BE MINIMAL AT CJ.
3. 6" STRIP OF SAF BEHIND THE CJ MAY
ENHANCE WATER RESISTANCE AT
THE JOINT.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 12
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CUT AND REMOVE A “U” SHAPED
PIECE FROM THE CENTER TO
THE TOP EDGE AND PLACE ON
THE SHEATHING WITH THE “U”
FACING UP.
MINIMUM 4” SAF APPLIED
DIRECTLY TO SHEATHING
4” OR LESS
PIPE DIAMETER
INSTALL WRB'S
OVER THE SAF.
APPLY A SEALANT BEAD
TO THE PERIMETER OF
THE PENETRATION.
CUT AND REMOVE A “U” SHAPED PIECE
FROM THE CENTER TO THE BOTTOM
EDGE. PLACE FORM THE TOP DOWN SO
THAT THE LEGS COVER THE LOWER SAF.
3
8
" G
AP
1
4
" G
AP
1
4
" G
AP
7/8” 3-COAT STUCCO
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLAIN
LOWER SAF BEHIND
UPPER SAF
BACKER ROD
AND SEALANT
SAF
WRB-DRAINAGE PLANE
WRB-BOND BREAK
LATH
STUCCO
BACKER ROD
AND SEALANT
STEP 1 STEP 2 STEP 3
STEP 4
STEP 5 STEP 6
NOTE:
LATH SHOULD BE CUT BACK FROM CONTACT
WITH THE PENETRATING ELEMENT 3/8” TO
PROTECT THE ENDS FROM THE CORROSION.
NOTE:
LATH SHOULD BE CUT BACK
FROM CONTACT WITH THE
PENETRATING ELEMENT 3/8”
TO PROTECT THE ENDS FROM
THE CORROSION.
STEP 1:
1. STEP 1 SAF SHALL EXTEND A MINIMUM 2
INCHES ABOVE AND 3 INCHES BELOW
THE PENETRATING ELEMENT.
2. WIDTH FROM SIDE OF PENETRATING
ELEMENT SHALL BE 1-3/4 T 4 INCHES.
STEP 2:
1. STEP 2 SAF SHALL EXTEND A MINIMUM 4
INCHES ABOVE AND 2 INCHES BELOW
THE PENETRATING ELEMENT.
2. WIDTH FROM SIDE OF PENETRATING
ELEMENT SHALL BE 1-3/4 T 4 INCHES.
NOTES:
1. "U", "V" (AS SHOWN) OR A STRAIGHT CUT WILL WORK
EQUALLY EFFECTIVELY.
2. WHERE FLEXIBLE SAF IS USED, SIMPLY CUT OUT A
HOLE TO ACCOMMODATE THE PENETRATING
ELEMENT AND APPLY DIRECTLY TO THE SUBSTRATE.
STEP 2 MAY BE OMITTED.
3. BEST PRACTICE: INSTALL A FLASHING DONUT OVER
THE PENETRATION DIRECTLY TO THE SUBSTRATE
AND SKIP TO STEP 3.
PENETRATION FLASHING SEQUENCE
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 13
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CONCRETE STOOP
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
SAF (RECOMMENDED)
FOUNDATION WEEP SCREED
RAISED CONCRETE PAD
(BEST PRACTICE)
FRAMING
NOTES
1. MINIMUM CLEARANCE = 2" OVER TREATED SLABS;
4" OVER UNTREATED SURFACES.
2. MINIMUM CLEARANCES MAY BE SET BY LOCAL
CODES. CHECK WITH THE LOCAL REQUIREMENTS.
FRAME COLUMN AT SLAB DETAIL
TREATED UNTREATED
2"
CLR
.
4"
CLR
.
1
4
" LATH GAP MIN.
SILL SEAL
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 14
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
V-GROOVE WITH SEALANT
WINDOW FRAME
WINDOW ISOLATION AND SEALANT OPTIONS
FOR MASONRY CONSTRUCTION
CAST-IN-PLACE CONCRETE,
GROUTED CMU OR
HOLLOW CORE CMU
1st COAT 1/4" THICK
2nd COAT 1/4" THICK
FINISH COAT 1/8" THICK
BACKER ROD AND SEALANT
1/4"
FASTENER SCREW
FIN WINDOW
ADHESIVE SEALANT
BEAD BETWEEN
WINDOW FIN AND FAB
FLUID-APPLIED BARRIER (FAB)
CAST-IN-PLACE CONCRETE,
GROUTED CMU OR
HOLLOW CORE CMU
NOTES:
1. CONTINUOUS PERIMETER SEALANT REQUIRED
ON EXTERIOR SIDE OF BUCK AND WINDOW
FRAME.
2. FLUID-APPLIED BARRIER SHALL NOT BE
APPLIED TO THE EXTERIOR WALL FACE OF
THE CONCRETE OR MASONRY. FLUID-APPLIED
BARRIERS MAY INHIBIT THE BOND OF THE
PLASTER TO THE SUBSTRATE.
3. REFER TO THE AAMA STANDARDS FOR MORE
INFORMATION.
FLUID-APPLIED BARRIER FLUID-APPLIED BARRIER
CONTINUOUS ADHESIVE SEALANT BEAD,
BOTH VERTICALLY AND HORIZONTALLY
(AT ENDS) BETWEEN BUCK AND FLUID
APPLIED BARRIER
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 15
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CONTROL JOINT CONTINUOUS
BEHIND STUCCO BAND
ANGLED CASING BEAD-SIZE VARIES
STUCCO - THICKNESS VARIES
CASING BEAD - SIZE VARIES
LATH
3
1
2
"1"
1
5
8
"
VA
RIE
SV
AR
IE
S
LATH TIED TO CJ
AT 7" O.C.
CMU WALL
CONTROL JOINT THROUGH STUCCO BAND DETAIL
NOTE
THE CONTROL AREA (PLEAT) SHALL BE KEPT FREE OF
PLASTER, SEALANT OR OTHER FOREIGN MATTER.
CUT CASING BEADS TO MEET THE ANGLE OF
THE CONTROL JOINT GROUND FLANGE
ATTACHMENT FLANGE
MID-WALL WEEP SCREED
PERFORATED ATTACHMENT FLANGE
NOTE
SEAL THIS MITERED SEAM BUT DO NOT SEAL
THE PLEATED FOLD TO THE WEEP SCREED.
THIS IS WHERE MOISTURE IS INTENDED TO WEEP.
NOTE:
1. LATH SHALL BE DISCONTINUOUS AT CONTROL JOINTS.
WHERE LATH IS INSTALLED PRIOR TO THE CONTROL
JOINT, THE LATH SHALL BE CUT BEHIND THE JOINT.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 16
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
LAP WRBs AND TAPE
OVER THE WEEP SCREED
ATTACHMENT FLANGE
WRB-DRAINAGE PLANE
SHEATHING
1
4
" LA
TH
GA
P M
IN
.
WEEP SCREED
MIN. 5"x5" "L" TYPE
GALVANIZED FLASHING
CAP SHINGLE - DO NOT NAIL.
INSTALL WITH ROOF CEMENT.
SHINGLE ROOF
5" (M
IN
.)
2" (M
IN
.)
ROOF CEMENT
ROOF / WALL FLASHING DETAIL
WRB-BOND BREAK
DO NOT PAINT OR SEAL THE INTERFACE.
THIS IS THE INTENDED WEEP POINT.
SAF
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 17
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CMU WALL CMU WALL CMU WALL
SEAL CAVITY WITH CLOSED-CELL,
EXPANDING FOAM. CUT FLUSH OR
RECEDE 1/8". APPLY A PAINTABLE,
HYBRID SEALANT OVER THE FOAM FILL.
ELECTRIC METER.
FIELD VERIFY LOCATION.
SEE PIPE FLASHING
DETAIL
SEE PIPE FLASHING
DETAIL
ELECTRIC METER.
FIELD VERIFY LOCATION.
APPLY SCRATCH AND BROWN COAT
STUCCO AFTER SEALING CONDUIT
PENETRATION. APPLY PRIMER AND
COLOR COAT PRIOR TO INSTALLATION
OF METER BOX.
ELECTRICAL SERVICE INSTALLATION DETAIL
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 18
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
1
1
0
°
MIN
IM
UM
3"
MINIMUM BY CODE 3/8"
1" IS RECOMMENDED
FOLDED SAFETY EDGE
2"
1"
FOLD UP EDGE
FOLD OVER OUTER CORNER
TO CREATE A SAFETY EDGE
PAN OR HEAD FLASHING FABRICATION DETAIL
PAN FLASHING SHALL BE
SET IN A BED OF SEALANT.
PAN FLASHING HEAD FLASHING
FOLDED SAFETY EDGE
MINIMUM BY CODE 3/8"
1" IS RECOMMENDED
MIN
IM
UM
3"
1"
HEAD FLASHING MUST BE
SEALED BEHIND THE DRIP
EDGE AT THE UNDERSIDE
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 19
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
METAL CAP FLASHING
CASING BEAD
SOLID COMPOSITE SHIM
SAF LAP DOWN OVER WRB.
4" MIN. RECOMMENDED.
WRB-DRAINAGE PLANE
SHEATHING
WRB-BOND BREAK
LATH
PARAPET - METAL CAP AT FRAMED WALL
NOTES:
1. JOINTS AT END OF CAP SECTIONS SHALL BE
EMBEDDED IN SEALANT RECOMMEND USE OF
SADDLE CAP AT SECTION JOINTS.
SEALANT BEAD
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 20
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
CMU
1
4
" LA
TH
GA
P M
IN
.
MID-WALL WEEP SCREED
FOAM ORNAMENTAL -CONCEALED MID-WALL OR CONTROL JOINT
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
SAF (RECOMMENDED)
12
1
SEALANT / ADHESIVE, BUILDER
PRE-APPROVED, APPLIED
CONTINUOUS ON THE TOP AND SIDES.
APPLY AFTER PRIMER AND PAINT.
ATTACH FOAM FEATURE AFTER PRIMER AND PAINT TO SURFACE
USING FOAM MANUFACTURER'S RECOMMENDED ADHESIVE OR
PRE-APPROVED EQUIVALENT. SOME MECHANICAL FASTENERS
MAY BE NECESSARY TO CARRY LARGER FOAM ORNAMENTAL
FEATURES. ATTACHMENTS SHOULD BE DESIGNED BY A
LICENSED PROFESSIONAL ENGINEER OR ARCHITECT.
VARIOUS FOAM FEATURES, ALL SHAPES
AND ALL LOCATIONS. SEALING PRIMER AND
PAINT APPLIED ON STUCCO PRIOR TO
INSTALLATION OF ALL FOAM FEATURES.
NO SEALANT SHALL BE APPLIED
AT THIS INTENDED WEEP POINT
5/8" STUCCO OR 1/2" CEMENTITIOUS FINISH,
INSTALL PER ASTM C926, C1063
FOAM ORNAMENTAL
SELF-ADHERED FLASHING (SAF)
AT CMU TO WOOD TRANSITION
SILL SEAL UNDER PLATE
(BEST PRACTICE)
1
8
" S
HE
AT
HIN
G G
AP
1
4
" M
IN
.
1" M
AX
.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 21
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
SAF (RECOMMENDED)
FOAM ORNAMENTAL ON FRAME - SURFACE APPLIED
FOAM ORNAMENTAL
SEALANT / ADHESIVE, BUILDER
PRE-APPROVED, APPLIED
CONTINUOUS ON THE TOP AND SIDES.
APPLY AFTER PRIMER AND PAINT.
12
1
ATTACH FOAM FEATURE AFTER PRIMER AND PAINT TO SURFACE
USING BUILDER PRE-APPROVED FOAM MANUFACTURER'S
RECOMMENDED ADHESIVE OR BUILDER PRE-APPROVED EQUIVALENT.
SOME MECHANICAL FASTENERS MAY BE NECESSARY TO CARRY
LARGER FOAM ORNAMENTAL FEATURES. ATTACHMENTS SHOULD BE
DESIGNED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT.
VARIOUS FOAM FEATURES, ALL SHAPES
AND ALL LOCATIONS. SEALING PRIMER AND
PAINT APPLIED ON STUCCO PRIOR TO
INSTALLATION OF ALL FOAM FEATURES.
FLASHING TAPE, BUILDER PRE-APPROVED,
OVER SEAM BETWEEN WOOD FRAMING AND
CMU UNDER THE WEEP SCREED TO AVOID
LEAKS CAUSED BY FASTENERS.
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 22
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
1-PIECE METAL COLLAR WATERTIGHT
COLLAR FLASHING AT BEAM
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
SAF (RECOMMENDED)
BACKER ROD AND SEALANT
1-PIECE COLLAR
2-PIECE COLLAR
SEAL TOP AND VERTICAL EDGES
OF WRB TO FLASHING
3
8
"-
1
2
" SEALANT JOINT
CONTINUOUS AROUND
RETURN LIP CONTINUOUS
NOTE: FAILURE OF COLLAR SEALANT MAY
ALLOW WATER PENETRATION BEHIND WRBs
PENETRATING BEAM AVOID WOOD. USE METAL OR PVC WITH SOLID,
SIMPLE CIRCLE, SQUARE OR RECTANGULAR PERIMETER SHAPES, I-BEAM,
C-CHANNEL OR L-ANGLE SHAPES CAN NOT BE EFFECTIVELY SEALED.
WATER WEEPS TO
CORNERS AND DOWN
2
"
M
I
N
.
F
L
A
N
G
E
3
"
-
4
"
P
R
E
F
E
R
R
E
D
2
"
M
I
N
.
F
L
A
N
G
E
3
"
-
4
"
P
R
E
F
E
R
R
E
D
SAF OVER LAP JOINT
TYP. BOTH SIDES
LAP AND SEAL (TOP
OVER BOTTOM) 2" MIN.
WATERTIGHT, SOLDERED OR
WELDED CONTINUOUS CORNERS
WATERTIGHT, SOLDERED OR
WELDED CONTINUOUS CORNERS
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 23
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
EXPANSION JOINT,
2 PIECE (SEE NOTE)
FINISH COAT
BROWN COAT
SCRATCH COAT
LATH
WRB-BOND BREAK
WRB-DRAINAGE PLANE
SHEATHING
9" MIN. STRIP OF SAF OVER SUBSTRATE JOINT.
SAF LAPS OVER TOP OF LOWER WRBs. TUCK SAF
INTO JOINT TO ALLOW RANGE OF MOVEMENT.
BACKER ROD AND
SEALANT ARE OPTIONAL
DO NOT FASTEN
THROUGH BOTH FEMALE
AND MALE FLANGES
SEAL ENDS AND OFFSET
VERTICAL JOINTS AT TOP
PIECE AND BOTTOM PIECE
SLOPED SURFACE
AND UNIMPEDED
EDGE FOR DRAINAGE
EMBED SEAL ENDS AND
MITER CORNERS OF
EXPANSION JOINT
X
RANGE OF
MOVEMENT
LIMITED BY
FASTENER
LOCATION
Y
NOTE:
1. CUSTOM PROFILE REQUIRED FOR Y>3/16" AND TO PROVIDE
SLOPED TOP PIECE AND UNIMPEDED EDGE FOR DRAINAGE.
2. THE X DIMENSION CONTROLS THE RANGE OF MOTION OF THE
JOINT. THE LOWER FLANGE SHOULD BE APPROXIMATELY
HALFWAY UP THE U CHANNEL OF THE UPPER FLANGE FOR
MAXIMUM RANGE OF MOTION.
Y
VARIES (MIN.
3
8
")
EX
PA
NS
IO
N JO
IN
T A
T
SU
BS
TR
AT
E M
OV
EM
EN
T JO
IN
T
WIDTH OF EXPANSION JOINT
DETERMINED BY THE
DESIGNER OF RECORD
FRAMING SUPPORT
BEHIND EXPANSION JOINT
2-PIECE PRE-MANUFACTURED EXPANSION JOINT
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 24
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING
HOUSEWRAP
SELF-ADHERING
FLASHING TAPE
WALL LEG AT
LEAST 4" TALL
DRIP LEG
1
4
" OUTWARD BEND
WINDOW HEAD TRIM
1
4
" TO
1
2
" GAP
BETWEEN SIDING
AND FLASHING
END DAM
Florida Lath & Plaster Bureau (FLAPB) details are for
illustration of construction methods.They are to be used as
guidelines by the design and/or construction team. You
should consult with your design and/or construction
specialists for specific construction requirements. Some
modification may be required for specific project conditions
or to meet local building code. FLAPB makes no
representation as to the suitability of any detail for specific
use at any location on any project. A qualified, licensed
architect or engineer must be consulted to specify the
detail for any specific use at any location on a project.
DTL 24
LEGEND
SHEATHING, 'OSB', PLYWOOD, DENSGLASS
SELF ADHERED FLASHING
PLASTER ACCESSORY
DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)
BOND BREAK WATER RESISTANT BARRIER (WRB)
SELF FURRING (SF) LATH
SCRATCH COAT
STUCCO
SILL SEAL
FOAM ORNAMENTALS
GALVANIZED METAL FLASHING