vertical control joint self-furred laththickness allowed by c926 over the 2 narrower block....

25
VERTICAL CONTROL JOINT ALWAYS CONTINUOUS SELF-FURRED LATH EMBED AND SEAL CJ ENDS AT INTERSECTIONS, BUTT JOINTS AND CORNERS OF ALL CJ WATER RESISTANT BARRIER, CONTINUOUS BEHIND CONTROL JOINTS HORIZONTAL CONTROL JOINT, BUTT TO VERTICAL CONTROL JOINT CUT FLANGES OF CONTROL JOINT SO AS TO CREATE A TIGHT FIT WITH A UNIFORM DEPTH INSIDE AND OUTSIDE CORNERS SHALL BE MITERED AND JOINTS EMBEDDED IN SEALANT NOTE 1. AT TIME OF INSTALLATION, EMBED ALL BUTT JOINTS, ENDS, ANGLES, CORNERS, AND INTERSECTIONS IN SEALANT. 2. LATH SHALL BE DISCONTINUOUS BEHIND CONTROL JOINTS. 3. COORDINATE THE DEPTH OF THE CONTROL GROUND FLANGE WITH THAT OF THE WEEP ACCESSORY INTO WHICH THE CONTROL JOINT TERMINATES BASED UPON THE SEQUENCING OF THE LATH AND CONTROL JOINT INSTALLATION SO AS TO ENSURE THAT THE GROUNDS OF EACH ACCESSORY ALIGN IN PLANE. CONTROL JOINT INTERSECTION SEALANT DETAIL Florida Lath & Plaster Bureau (FLAPB) details are for illustration of construction methods.They are to be used as guidelines by the design and/or construction team. You should consult with your design and/or construction specialists for specific construction requirements. Some modification may be required for specific project conditions or to meet local building code. FLAPB makes no representation as to the suitability of any detail for specific use at any location on any project. A qualified, licensed architect or engineer must be consulted to specify the detail for any specific use at any location on a project. LEGEND SHEATHING, 'OSB', PLYWOOD, DENSGLASS SELF ADHERED FLASHING PLASTER ACCESSORY DRAINAGE PLANE WATER RESISTANT BARRIER (WRB) BOND BREAK WATER RESISTANT BARRIER (WRB) SELF FURRING (SF) LATH SCRATCH COAT STUCCO SILL SEAL FOAM ORNAMENTALS GALVANIZED METAL FLASHING DTL 1

Upload: others

Post on 22-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

VERTICAL CONTROL JOINT

ALWAYS CONTINUOUS

SELF-FURRED LATH

EMBED AND SEAL CJ ENDS AT

INTERSECTIONS, BUTT JOINTS

AND CORNERS OF ALL CJ

WATER RESISTANT BARRIER,

CONTINUOUS BEHIND CONTROL JOINTS

HORIZONTAL CONTROL JOINT,

BUTT TO VERTICAL CONTROL JOINT

CUT FLANGES OF CONTROL JOINT SO AS TO

CREATE A TIGHT FIT WITH A UNIFORM DEPTH

INSIDE AND OUTSIDE CORNERS SHALL BE

MITERED AND JOINTS EMBEDDED IN SEALANT

NOTE

1. AT TIME OF INSTALLATION, EMBED ALL BUTT JOINTS, ENDS,

ANGLES, CORNERS, AND INTERSECTIONS IN SEALANT.

2. LATH SHALL BE DISCONTINUOUS BEHIND CONTROL JOINTS.

3. COORDINATE THE DEPTH OF THE CONTROL GROUND

FLANGE WITH THAT OF THE WEEP ACCESSORY INTO

WHICH THE CONTROL JOINT TERMINATES BASED UPON

THE SEQUENCING OF THE LATH AND CONTROL JOINT

INSTALLATION SO AS TO ENSURE THAT THE GROUNDS OF

EACH ACCESSORY ALIGN IN PLANE.

CONTROL JOINT INTERSECTION SEALANT DETAIL

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

DTL 1

Page 2: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

7

1

2

"

7

5

8

"

7

3

4

"

7

1

2

"

7

5

8

"

7

3

4

"

RESULTING STUCCO THICKNESS 1/2"

MORTAR JOINT STRUCK FLUSH WITH

BLOCK FACE

RESULTING STUCCO THICKNESS 5/8"

MORTAR JOINT STRUCK FLUSH WITH

BLOCK FACE

RESULTING STUCCO THICKNESS 3/8"

ASTM C90 COMPLIANT CONCRETE

MASONRY UNITS

STUCCO THICKNESS VARIATIONS DUE

TO ALLOWABLE CMU SIZE TOLERANCES

NOTES

1. IN EITHER CASE STUCCO CANNOT BE APPLIED TO CODE/STANDARD

COMPLIANT THICKNESS WITHOUT SOME TOLERANCE.

2. IN ORDER TO MAINTAIN THE REQUIRED 1/2" NOMINAL THICKNESS AND KEEP

THE FINISH COAT PLANE TRUE AND PLUMB, THE STUCCO MAY EXCEED THE

THICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK.

3. RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF

TABLE 4 OF ASTM C926 TO BE EVALUATED BY A DESIGN PROFESSIONAL

FOR AUGMENTATION REQUIREMENTS OF SECTION 6.2 OF ASTM C926.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 2

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 3: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

7

8

" STUCCO SYSTEM

7

8

" STUCCO SYSTEM

5

8

" RESULTING

STUCCO THICKNESS

1-

1

8

" RESULTING

STUCCO THICKNESS

WOOD FRAMING

SHEATHING

TRUE VERTICAL TRUE VERTICAL

STUCCO THICKNESS VARIATIONS DUE TO FRAMING

NOTE

1. IN EITHER CASE STUCCO CANNOT BE APPLIED TO CODE/ STANDARD COMPLIANT

THICKNESS WITHOUT SOME TOLERANCE.

2. IN ORDER TO MAINTAIN THE REQUIRED 7/8" THICKNESS AND KEEP THE FINISH

COAT PLANE TRUE AND PLUMB, THE STUCCO WOULD HAVE TO EXCEED THE

THICKNESS ALLOWED BY C926, EITHER IN THE MIDDLE OR ON THE ENDS

RESPECTIVELY.

3. RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4

OF ASTM C926 TO BE EVALUATED BY A DESIGN PROFESSIONAL FOR CORRECTIVE

OPTIONS.

EXTERIOR EXTERIOR

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 3

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 4: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

2 LAYERS OF WRB AT BOTTOM

OF BEAM AND/OR STRIP OF SAF.

(SIM. TO FLASHING WINDOW)

W

A

L

L

S

H

E

A

T

H

I

N

G

PENETRATING

BEAM

1-PIECE OR 2-PIECE

WATERTIGHT COLLAR

MAINTAIN MIN

1

4

" GAP

BETWEEN BEAM AND COLLAR

2 LAYERS

TOP WRBs (AND/OR

STRIP OF SAF AND

WRB) OVER COLLAR

INSTALL WRBs OVER

TOP FLASHING FLANGE

BOTTOM OF COLLAR

OVER WRB

LATH

INSTALL BACKER ROD AND

SEALANT CONTINUOUS

AROUND ALL SIDES

3

8

" GAP FOR BACKER ROD

AND SEALANT

2

"

M

I

N

.

L

A

P

O

F

W

R

B

SEQUENCE FLASHING - 1-PIECE COLLAR

(2-PIECE, SIM.)

COLLAR FLASHING SEQUENCE

1. WRB LAYERS AT BOTTOM OF BEAM 2. INSERT FLASHING COLLAR INTO BEAM 3. INSTALLMENT OF WRBs

OVER TOP FLASHING FLANGE

4. BACKER ROD AND SEALANT 5. LATH AND WRB

"BEST PRACTICE" FIRST STEP

SAF OR FLUID-APPLIED

BARRIER

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 4

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 5: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

3 COAT STUCCO SYSTEM

DIRECT APPLIED STUCCO

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING, 'OSB', PLYWOOD,

DENSGLASS

LAPS IN ACCORDANCE WITH

MANUFACTURERS SPECIFICATION

SAF (RECOMMENDED)

3

1

2

" FLANGE

SILL SEAL

PLASTER STOP

DRIP SCREED. THE LEADING EDGE

OF THE WEEP SCREED SHALL NOT

BE PAINTED OR SEALED.

1

8

" S

HE

AT

HIN

G G

AP

1

4

" M

IN

.

1" M

AX

.

CONTINUOUS BACKER ROD AND

SEALANT REQUIRED. COORDINATE

ACCESSORY DIMENSIONS AND

ANGLE TO ENABLE BACKER ROD

AND SEALANT MAINTENANCE.

FRAME TO MASONRY TRANSITION EXPANSION

WITH DRIP SCREED DETAIL

FASTENERS WITHIN

1

2

" OF TOP OF WEEP

SCREED INTO VERTICAL FRAMING

MEMBERS ABOVE TRANSITION

1

4

" LATH GAP MIN.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 5

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 6: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CMU

DOUBLE BACK

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

LAPS IN ACCORDANCE WITH

MANUFACTURERS SPECIFICATION

THE LEADING EDGE OF THE

WEEP SCREED SHALL NOT BE

PAINTED OR SEALED.

SAF (RECOMMENDED)

MID-WALL WEEP SCREED

NOTES

1. SELF ADHERED FLASHING SHOULD NOT EXTEND PAST THE

MID-WAY POINT OF THE UPPER ROW OF PERFORATIONS IN

THE LOWER FLANGE OF THE SCREED TO ENSURE BOND OF

THE PLASTER TO THE CMU.

2. STAGGER JOINTS (HORIZONTAL AND VERTICAL) IN WATER

RESISTIVE BARRIER AND FOR LATH.

3. APPLIED TEXTURE IS NOT A PLASTER COAT AND IS NOT

COUNTED IN THICKNESS MEASUREMENT.

SEQUENCING OF STUCCO COATS DETAIL

1

8

" S

HE

AT

HIN

G G

AP

1

4

" M

IN

.

1" M

AX

.

LATH FASTENERS TO BE

PLACED ABOVE THE

CENTER OF SILL PLATE

FASTENERS WITHIN

1

2

" OF TOP OF

WEEP SCREED INTO VERTICAL FRAMING

MEMBERS ABOVE TRANSITION

SILL SEAL

1

4

" LATH GAP MIN.

AN UNPAINTED/SEALED NARROW KERF

CUT HERE WILL FACILITATE DRAINAGE

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 6

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 7: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

LATH

CMU

3 COAT STUCCO SYSTEM

WRB-DRAINAGE PLANE

SHEATHING

LAPS IN ACCORDANCE

WITH MANUFACTURERS

SPECIFICATION

WRB-BOND BREAK

SAF (RECOMMENDED)

MID-WALL WEEP SCREED

NOTES

1. SELF ADHERED FLASHING SHOULD NOT EXTEND PAST

THE MID-WAY POINT OF THE UPPER ROW OF

PERFORATIONS IN THE LOWER FLANGE OF THE SCREED

TO ENSURE BOND OF THE PLASTER TO THE CMU.

2. STAGGER JOINTS (HORIZONTAL AND VERTICAL) IN

WATER RESISTIVE BARRIER AND FOR LATH.

TRANSITION OR MID-WALL WEEP SCREED DETAIL

THE LEADING EDGE OF THE

WEEP SCREED SHALL NOT BE

PAINTED OR SEALED.

1

8

" S

HE

AT

HIN

G G

AP

1

4

" M

IN

.

1" M

AX

.

LATH FASTENERS TO BE

PLACED ABOVE THE

CENTER OF SILL PLATE

FASTENERS WITHIN

1

2

" OF TOP OF

WEEP SCREED INTO VERTICAL FRAMING

MEMBERS ABOVE TRANSITION

1

4

" LATH GAP MIN.

AN UNPAINTED/SEALED NARROW KERF

CUT HERE WILL FACILITATE DRAINAGE

SILL SEAL

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 7

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 8: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

HOLES ARE NOT FOR DRAINAGE.

THEY ASSIST IN KEYING THE

ACCESSORY TO THE STUCCO.

SCREED

6"

MIN

.

BACK OF SCREED CAN BE SEALED FOR

AIR INFILTRATION, INSECT INTRUSION

AND WATER PENETRATION WHERE

SUSCEPTIBLE TO WIND EXPOSURE

LATH

SLAB ON FOUNDATION

3 COAT STUCCO SYSTEM

WRB-DRAINAGE PLANE

LAP OVER TOP OF SCREED

SOLID SHEATHING FLUSH

WITH FOUNDATION EDGE

WRB-BOND BREAK

NO FASTENERS

BELOW TRANSITION

FINAL LANDSCAPE

RECOMMENDED STRIP OF

SAF OVER SCREED FOR

WATER RESISTANCE

1/8" MIN. GAP BELOW WOOD-BASED

SHEATHING FOR CAPILLARY BREAK

OR EXPANSION

PROVIDE CONTINUOUS WEEP.

THE LEADING EDGE OF THE

WEEP SCREED SHALL NOT BE

PAINTED OR SEALED.

GRADE

FOUNDATION WEEP SCREED DETAIL

NOTES

1. HEIGHT ABOVE GRADE IS GOVERNED BY LOCAL

BUILDING CODE OR MANUFACTURER’S

INSTRUCTIONS. CHECK WITH YOUR LOCAL CODE

JURISDICTION FOR CLEAR SPACE REQUIREMENTS.

2. LAP SCREED OVER SLAB/SILL JOINT A MIN. OF 1/4"

AND A MAXIMUM OF 1" TO PREVENT WATER

INTRUSION UNDER SILL.

3. USE A BEAD OF SEALANT BETWEEN SHEATHING

BASE AND CONCRETE OR A STRIP OF SAF OVER

THE JUNCTURE BEHIND THE SCREED TO PREVENT

WATER OR INSECT INTRUSION.

4. SCREEDS FOR USE BEHIND LATH ARE REQUIRED

TO HAVE A 3-1/2" ATTACHMENT FLANGE.

FASTENERS SHOULD BE PLACED IN THE TOP 1/2"

OF THE SCREED INTO VERTICAL FRAMING

MEMBERS.

5. BACK OF SCREED CAN BE SEALED FOR AIR

INFILTRATION AND WATER PENETRATION WHERE

SUSCEPTIBLE TO WIND EXPOSURE.

6. FOUNDATION WEEP SCREEDS ARE NEITHER

REQUIRED NOR FUNCTIONAL ON CMU WALLS

WHERE STUCCO IS DIRECTLY APPLIED.

THE LEADING EDGE OF THE

WEEP SCREED SHALL NOT BE

PAINTED OR SEALED.

1

4

" M

IN

.

1" M

AX

.

LATH FASTENERS TO BE PLACED

ABOVE THE CENTER OF SILL PLATE

FASTENERS WITHIN

1

2

" OF TOP OF

WEEP SCREED INTO VERTICAL FRAMING

MEMBERS ABOVE TRANSITION

1

4

" LATH GAP MIN.

AN UNPAINTED/SEALED NARROW KERF

CUT HERE WILL FACILITATE DRAINAGE

SLAB ON FOUNDATION

1

8

" S

HE

AT

HIN

G G

AP

SILL SEAL

SILL SEAL

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 8

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 9: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

3 COAT STUCCO SYSTEM

SHEATHING, 'OSB',

PLYWOOD, DENSGLASS

STRIP OF SAF

3

1

2

" FLANGE

PLASTER STOP

DRIP SCREED

THIS GAP IS A RESULT OF NATURAL

SHRINKAGE. PROVIDE CONTINUOUS

WEEP. THE LEADING EDGE OF THE WEEP

SHALL NOT BE PAINTED OR SEALED.

CONTINUOUS BACKER ROD

& SEALANT REQUIRED

1

4

" G

AP

1

4

" LA

TH

GA

P M

IN

.

WRAP DP WRB ONTO THE VERTICAL

SURFACE TO TOP OF FLANGE AS AN AIR

BARRIER. DP WRB SHOULD EXTEND TO

THE TOP OF THE ACCESSORY FLANGE

TO BE TRIMMED OFF AT THAT POINT

VERTICAL EXTERIOR

CEILING (SOFFIT)

SOFFIT TO EXTERIOR FACE DRIP DETAIL

NOTES:

1. A DESIGNER PROFESSIONAL SHALL DETAIL THE CONDITION WHERE WRBs

ARE EMPLOYED ON HORIZONTAL SURFACES.

2. LATH SHALL BE TERMINATED A MINIMUM 1/4 INCH ABOVE THE GROUND

FLANGE OF THE DRIP SCREED TO RESIST CORROSION.

FASTENERS WITHIN

1

2

" OF TOP OF

WEEP SCREED INTO VERTICAL FRAMING

MEMBERS ABOVE TRANSITION

CONTINUOUS BACKER ROD

& SEALANT REQUIRED

PLASTER STOP

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 9

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 10: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

STUD

WRB-DRAINAGE PLANE

WRAP

WRB-BOND BREAK

(PAPER)

SF LATH

1"

1

8

" S

HE

AT

HIN

G G

AP

3 COAT STUCCO SYSTEM

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING, 'OSB', PLYWOOD,

DENSGLASS

SAF (RECOMMENDED)

CONTINUOUS BACKER ROD AND SEALANT

REQUIRED. COORDINATE ACCESSORY

DIMENSIONS AND ANGLE TO ENABLE

BACKER ROD AND SEALANT MAINTENANCE

7

8

" PLASTIC STOP OR

BACKER ROD

Z FLASHING SHOULD

COVER GAP IN SHEATHING

(1" GROUND, 31/2" FLANGE)

SILL PLATE

FLOORING

TOP PLATE

FRAME TO FRAME TRANSITION EXPANSION

WITH DRIP SCREED DETAIL

NOTES:

1. THE DRAINAGE PLANE WRB SHALL BE

PLACED FIRST SO THAT THEY EXTEND

BETWEEN 2 AND 3 INCHES ABOVE THE

GROUND FLANGE OF THE DRIP SCREED.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 10

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 11: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

STUCCO SYSTEM

CIP WALL (SHEAR WALL, ETC.)

SEALANT ON BOND BREAKER

BACKER ROD AND SEALANT

PLASTERSTOP

CASING BEAD

DIRECT APPLIED ON

CMU / SHEAR WALL DETAIL

NOTES:

1. THIS OPTION ALLOWS FOR DEVIATIONS IN

VERTICAL ALIGNMENT BETWEEN CIP AND CMU

AND DIFFERENTIAL MOVEMENT BETWEEN TWO

SEPARATE STRUCTURAL ELEMENTS. THERE

SHOULD BE A MASONRY CONTROL JOINT AT

THIS LOCATION.

2. DOUBLE-BACK OR DOUBLE-UP COAT. THE

BROWN COAT PLASTER APPLIED TO THE

SCRATCH COAT PLASTER BEFORE THE

SCRATCH COAT PLASTER HAS SET.

SURFACE PREPARATION NOTES:

1. SPECIFY BLOCK SURFACE

CHARACTERISTICS - COARSE.

2. TEXTURE IS NOT A COAT.

A

DETAIL 'A' (OPTIONAL )

EXPANSION JOINT

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 11

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 12: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

TEXTURE

BROWN COAT

SCRATCH COAT

LATH (SEE NOTES)

WRB-BOND BREAK

WRB-DRAINAGE PLANE

CONT. SUBSTRATE SHEATHING

6" STRIP SAF (NOT REQD.)

1/2 INCH CORROSION-RESISTANT

SCREWS.

CJ CAN BE APPLIED BEFORE OR

AFTER LATH, (CJ OVER LATH MAY

NEED TO REDUCE GROUND FOR

UNIFORM DEPTH)

TIE CJ TO LATH

FINISH COAT

2. VERTICAL CONTROL JOINT

3. HORIZONTAL AND VERTICAL

CONTROL JOINTS

1. HORIZONTAL CONTROL JOINT

NOTES

A. DISCONTINUOUS LATH BEHIND CJ

PER ASTM C1063.

B. DISCONTINUOUS LATH OVER CJ BY

SOME LATHERS.

C. NOTE: METHOD A OR B ABOVE WILL

AFFECT THE DEPTH OF THE GROUND

OF THE CONTROL JOINT

ACCESSORY.

CONSIDERATIONS

1. CJ IS INTENDED TO PROVIDE

LOCATION FOR STUCCO CRACKS TO

OCCUR DURING THE CURING PERIOD.

2. SUBSTRATE MOVEMENT IS

EXPECTED TO BE MINIMAL AT CJ.

3. 6" STRIP OF SAF BEHIND THE CJ MAY

ENHANCE WATER RESISTANCE AT

THE JOINT.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 12

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 13: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CUT AND REMOVE A “U” SHAPED

PIECE FROM THE CENTER TO

THE TOP EDGE AND PLACE ON

THE SHEATHING WITH THE “U”

FACING UP.

MINIMUM 4” SAF APPLIED

DIRECTLY TO SHEATHING

4” OR LESS

PIPE DIAMETER

INSTALL WRB'S

OVER THE SAF.

APPLY A SEALANT BEAD

TO THE PERIMETER OF

THE PENETRATION.

CUT AND REMOVE A “U” SHAPED PIECE

FROM THE CENTER TO THE BOTTOM

EDGE. PLACE FORM THE TOP DOWN SO

THAT THE LEGS COVER THE LOWER SAF.

3

8

" G

AP

1

4

" G

AP

1

4

" G

AP

7/8” 3-COAT STUCCO

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLAIN

LOWER SAF BEHIND

UPPER SAF

BACKER ROD

AND SEALANT

SAF

WRB-DRAINAGE PLANE

WRB-BOND BREAK

LATH

STUCCO

BACKER ROD

AND SEALANT

STEP 1 STEP 2 STEP 3

STEP 4

STEP 5 STEP 6

NOTE:

LATH SHOULD BE CUT BACK FROM CONTACT

WITH THE PENETRATING ELEMENT 3/8” TO

PROTECT THE ENDS FROM THE CORROSION.

NOTE:

LATH SHOULD BE CUT BACK

FROM CONTACT WITH THE

PENETRATING ELEMENT 3/8”

TO PROTECT THE ENDS FROM

THE CORROSION.

STEP 1:

1. STEP 1 SAF SHALL EXTEND A MINIMUM 2

INCHES ABOVE AND 3 INCHES BELOW

THE PENETRATING ELEMENT.

2. WIDTH FROM SIDE OF PENETRATING

ELEMENT SHALL BE 1-3/4 T 4 INCHES.

STEP 2:

1. STEP 2 SAF SHALL EXTEND A MINIMUM 4

INCHES ABOVE AND 2 INCHES BELOW

THE PENETRATING ELEMENT.

2. WIDTH FROM SIDE OF PENETRATING

ELEMENT SHALL BE 1-3/4 T 4 INCHES.

NOTES:

1. "U", "V" (AS SHOWN) OR A STRAIGHT CUT WILL WORK

EQUALLY EFFECTIVELY.

2. WHERE FLEXIBLE SAF IS USED, SIMPLY CUT OUT A

HOLE TO ACCOMMODATE THE PENETRATING

ELEMENT AND APPLY DIRECTLY TO THE SUBSTRATE.

STEP 2 MAY BE OMITTED.

3. BEST PRACTICE: INSTALL A FLASHING DONUT OVER

THE PENETRATION DIRECTLY TO THE SUBSTRATE

AND SKIP TO STEP 3.

PENETRATION FLASHING SEQUENCE

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 13

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 14: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CONCRETE STOOP

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

SAF (RECOMMENDED)

FOUNDATION WEEP SCREED

RAISED CONCRETE PAD

(BEST PRACTICE)

FRAMING

NOTES

1. MINIMUM CLEARANCE = 2" OVER TREATED SLABS;

4" OVER UNTREATED SURFACES.

2. MINIMUM CLEARANCES MAY BE SET BY LOCAL

CODES. CHECK WITH THE LOCAL REQUIREMENTS.

FRAME COLUMN AT SLAB DETAIL

TREATED UNTREATED

2"

CLR

.

4"

CLR

.

1

4

" LATH GAP MIN.

SILL SEAL

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 14

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 15: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

V-GROOVE WITH SEALANT

WINDOW FRAME

WINDOW ISOLATION AND SEALANT OPTIONS

FOR MASONRY CONSTRUCTION

CAST-IN-PLACE CONCRETE,

GROUTED CMU OR

HOLLOW CORE CMU

1st COAT 1/4" THICK

2nd COAT 1/4" THICK

FINISH COAT 1/8" THICK

BACKER ROD AND SEALANT

1/4"

FASTENER SCREW

FIN WINDOW

ADHESIVE SEALANT

BEAD BETWEEN

WINDOW FIN AND FAB

FLUID-APPLIED BARRIER (FAB)

CAST-IN-PLACE CONCRETE,

GROUTED CMU OR

HOLLOW CORE CMU

NOTES:

1. CONTINUOUS PERIMETER SEALANT REQUIRED

ON EXTERIOR SIDE OF BUCK AND WINDOW

FRAME.

2. FLUID-APPLIED BARRIER SHALL NOT BE

APPLIED TO THE EXTERIOR WALL FACE OF

THE CONCRETE OR MASONRY. FLUID-APPLIED

BARRIERS MAY INHIBIT THE BOND OF THE

PLASTER TO THE SUBSTRATE.

3. REFER TO THE AAMA STANDARDS FOR MORE

INFORMATION.

FLUID-APPLIED BARRIER FLUID-APPLIED BARRIER

CONTINUOUS ADHESIVE SEALANT BEAD,

BOTH VERTICALLY AND HORIZONTALLY

(AT ENDS) BETWEEN BUCK AND FLUID

APPLIED BARRIER

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 15

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 16: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CONTROL JOINT CONTINUOUS

BEHIND STUCCO BAND

ANGLED CASING BEAD-SIZE VARIES

STUCCO - THICKNESS VARIES

CASING BEAD - SIZE VARIES

LATH

3

1

2

"1"

1

5

8

"

VA

RIE

SV

AR

IE

S

LATH TIED TO CJ

AT 7" O.C.

CMU WALL

CONTROL JOINT THROUGH STUCCO BAND DETAIL

NOTE

THE CONTROL AREA (PLEAT) SHALL BE KEPT FREE OF

PLASTER, SEALANT OR OTHER FOREIGN MATTER.

CUT CASING BEADS TO MEET THE ANGLE OF

THE CONTROL JOINT GROUND FLANGE

ATTACHMENT FLANGE

MID-WALL WEEP SCREED

PERFORATED ATTACHMENT FLANGE

NOTE

SEAL THIS MITERED SEAM BUT DO NOT SEAL

THE PLEATED FOLD TO THE WEEP SCREED.

THIS IS WHERE MOISTURE IS INTENDED TO WEEP.

NOTE:

1. LATH SHALL BE DISCONTINUOUS AT CONTROL JOINTS.

WHERE LATH IS INSTALLED PRIOR TO THE CONTROL

JOINT, THE LATH SHALL BE CUT BEHIND THE JOINT.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 16

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 17: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

LAP WRBs AND TAPE

OVER THE WEEP SCREED

ATTACHMENT FLANGE

WRB-DRAINAGE PLANE

SHEATHING

1

4

" LA

TH

GA

P M

IN

.

WEEP SCREED

MIN. 5"x5" "L" TYPE

GALVANIZED FLASHING

CAP SHINGLE - DO NOT NAIL.

INSTALL WITH ROOF CEMENT.

SHINGLE ROOF

5" (M

IN

.)

2" (M

IN

.)

ROOF CEMENT

ROOF / WALL FLASHING DETAIL

WRB-BOND BREAK

DO NOT PAINT OR SEAL THE INTERFACE.

THIS IS THE INTENDED WEEP POINT.

SAF

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 17

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 18: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CMU WALL CMU WALL CMU WALL

SEAL CAVITY WITH CLOSED-CELL,

EXPANDING FOAM. CUT FLUSH OR

RECEDE 1/8". APPLY A PAINTABLE,

HYBRID SEALANT OVER THE FOAM FILL.

ELECTRIC METER.

FIELD VERIFY LOCATION.

SEE PIPE FLASHING

DETAIL

SEE PIPE FLASHING

DETAIL

ELECTRIC METER.

FIELD VERIFY LOCATION.

APPLY SCRATCH AND BROWN COAT

STUCCO AFTER SEALING CONDUIT

PENETRATION. APPLY PRIMER AND

COLOR COAT PRIOR TO INSTALLATION

OF METER BOX.

ELECTRICAL SERVICE INSTALLATION DETAIL

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 18

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 19: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

1

1

0

°

MIN

IM

UM

3"

MINIMUM BY CODE 3/8"

1" IS RECOMMENDED

FOLDED SAFETY EDGE

2"

1"

FOLD UP EDGE

FOLD OVER OUTER CORNER

TO CREATE A SAFETY EDGE

PAN OR HEAD FLASHING FABRICATION DETAIL

PAN FLASHING SHALL BE

SET IN A BED OF SEALANT.

PAN FLASHING HEAD FLASHING

FOLDED SAFETY EDGE

MINIMUM BY CODE 3/8"

1" IS RECOMMENDED

MIN

IM

UM

3"

1"

HEAD FLASHING MUST BE

SEALED BEHIND THE DRIP

EDGE AT THE UNDERSIDE

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 19

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 20: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

METAL CAP FLASHING

CASING BEAD

SOLID COMPOSITE SHIM

SAF LAP DOWN OVER WRB.

4" MIN. RECOMMENDED.

WRB-DRAINAGE PLANE

SHEATHING

WRB-BOND BREAK

LATH

PARAPET - METAL CAP AT FRAMED WALL

NOTES:

1. JOINTS AT END OF CAP SECTIONS SHALL BE

EMBEDDED IN SEALANT RECOMMEND USE OF

SADDLE CAP AT SECTION JOINTS.

SEALANT BEAD

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 20

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 21: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

CMU

1

4

" LA

TH

GA

P M

IN

.

MID-WALL WEEP SCREED

FOAM ORNAMENTAL -CONCEALED MID-WALL OR CONTROL JOINT

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

SAF (RECOMMENDED)

12

1

SEALANT / ADHESIVE, BUILDER

PRE-APPROVED, APPLIED

CONTINUOUS ON THE TOP AND SIDES.

APPLY AFTER PRIMER AND PAINT.

ATTACH FOAM FEATURE AFTER PRIMER AND PAINT TO SURFACE

USING FOAM MANUFACTURER'S RECOMMENDED ADHESIVE OR

PRE-APPROVED EQUIVALENT. SOME MECHANICAL FASTENERS

MAY BE NECESSARY TO CARRY LARGER FOAM ORNAMENTAL

FEATURES. ATTACHMENTS SHOULD BE DESIGNED BY A

LICENSED PROFESSIONAL ENGINEER OR ARCHITECT.

VARIOUS FOAM FEATURES, ALL SHAPES

AND ALL LOCATIONS. SEALING PRIMER AND

PAINT APPLIED ON STUCCO PRIOR TO

INSTALLATION OF ALL FOAM FEATURES.

NO SEALANT SHALL BE APPLIED

AT THIS INTENDED WEEP POINT

5/8" STUCCO OR 1/2" CEMENTITIOUS FINISH,

INSTALL PER ASTM C926, C1063

FOAM ORNAMENTAL

SELF-ADHERED FLASHING (SAF)

AT CMU TO WOOD TRANSITION

SILL SEAL UNDER PLATE

(BEST PRACTICE)

1

8

" S

HE

AT

HIN

G G

AP

1

4

" M

IN

.

1" M

AX

.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 21

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 22: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

SAF (RECOMMENDED)

FOAM ORNAMENTAL ON FRAME - SURFACE APPLIED

FOAM ORNAMENTAL

SEALANT / ADHESIVE, BUILDER

PRE-APPROVED, APPLIED

CONTINUOUS ON THE TOP AND SIDES.

APPLY AFTER PRIMER AND PAINT.

12

1

ATTACH FOAM FEATURE AFTER PRIMER AND PAINT TO SURFACE

USING BUILDER PRE-APPROVED FOAM MANUFACTURER'S

RECOMMENDED ADHESIVE OR BUILDER PRE-APPROVED EQUIVALENT.

SOME MECHANICAL FASTENERS MAY BE NECESSARY TO CARRY

LARGER FOAM ORNAMENTAL FEATURES. ATTACHMENTS SHOULD BE

DESIGNED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT.

VARIOUS FOAM FEATURES, ALL SHAPES

AND ALL LOCATIONS. SEALING PRIMER AND

PAINT APPLIED ON STUCCO PRIOR TO

INSTALLATION OF ALL FOAM FEATURES.

FLASHING TAPE, BUILDER PRE-APPROVED,

OVER SEAM BETWEEN WOOD FRAMING AND

CMU UNDER THE WEEP SCREED TO AVOID

LEAKS CAUSED BY FASTENERS.

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 22

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 23: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

1-PIECE METAL COLLAR WATERTIGHT

COLLAR FLASHING AT BEAM

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

SAF (RECOMMENDED)

BACKER ROD AND SEALANT

1-PIECE COLLAR

2-PIECE COLLAR

SEAL TOP AND VERTICAL EDGES

OF WRB TO FLASHING

3

8

"-

1

2

" SEALANT JOINT

CONTINUOUS AROUND

RETURN LIP CONTINUOUS

NOTE: FAILURE OF COLLAR SEALANT MAY

ALLOW WATER PENETRATION BEHIND WRBs

PENETRATING BEAM AVOID WOOD. USE METAL OR PVC WITH SOLID,

SIMPLE CIRCLE, SQUARE OR RECTANGULAR PERIMETER SHAPES, I-BEAM,

C-CHANNEL OR L-ANGLE SHAPES CAN NOT BE EFFECTIVELY SEALED.

WATER WEEPS TO

CORNERS AND DOWN

2

"

M

I

N

.

F

L

A

N

G

E

3

"

-

4

"

P

R

E

F

E

R

R

E

D

2

"

M

I

N

.

F

L

A

N

G

E

3

"

-

4

"

P

R

E

F

E

R

R

E

D

SAF OVER LAP JOINT

TYP. BOTH SIDES

LAP AND SEAL (TOP

OVER BOTTOM) 2" MIN.

WATERTIGHT, SOLDERED OR

WELDED CONTINUOUS CORNERS

WATERTIGHT, SOLDERED OR

WELDED CONTINUOUS CORNERS

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 23

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 24: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

EXPANSION JOINT,

2 PIECE (SEE NOTE)

FINISH COAT

BROWN COAT

SCRATCH COAT

LATH

WRB-BOND BREAK

WRB-DRAINAGE PLANE

SHEATHING

9" MIN. STRIP OF SAF OVER SUBSTRATE JOINT.

SAF LAPS OVER TOP OF LOWER WRBs. TUCK SAF

INTO JOINT TO ALLOW RANGE OF MOVEMENT.

BACKER ROD AND

SEALANT ARE OPTIONAL

DO NOT FASTEN

THROUGH BOTH FEMALE

AND MALE FLANGES

SEAL ENDS AND OFFSET

VERTICAL JOINTS AT TOP

PIECE AND BOTTOM PIECE

SLOPED SURFACE

AND UNIMPEDED

EDGE FOR DRAINAGE

EMBED SEAL ENDS AND

MITER CORNERS OF

EXPANSION JOINT

X

RANGE OF

MOVEMENT

LIMITED BY

FASTENER

LOCATION

Y

NOTE:

1. CUSTOM PROFILE REQUIRED FOR Y>3/16" AND TO PROVIDE

SLOPED TOP PIECE AND UNIMPEDED EDGE FOR DRAINAGE.

2. THE X DIMENSION CONTROLS THE RANGE OF MOTION OF THE

JOINT. THE LOWER FLANGE SHOULD BE APPROXIMATELY

HALFWAY UP THE U CHANNEL OF THE UPPER FLANGE FOR

MAXIMUM RANGE OF MOTION.

Y

VARIES (MIN.

3

8

")

EX

PA

NS

IO

N JO

IN

T A

T

SU

BS

TR

AT

E M

OV

EM

EN

T JO

IN

T

WIDTH OF EXPANSION JOINT

DETERMINED BY THE

DESIGNER OF RECORD

FRAMING SUPPORT

BEHIND EXPANSION JOINT

2-PIECE PRE-MANUFACTURED EXPANSION JOINT

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 24

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING

Page 25: VERTICAL CONTROL JOINT SELF-FURRED LATHTHICKNESS ALLOWED BY C926 OVER THE 2 NARROWER BLOCK. 3.RESULTING PLASTER THICKNESSES IN EXCESS OF THE ALLOWANCES OF TABLE 4 OF ASTM C926 TO BE

HOUSEWRAP

SELF-ADHERING

FLASHING TAPE

WALL LEG AT

LEAST 4" TALL

DRIP LEG

1

4

" OUTWARD BEND

WINDOW HEAD TRIM

1

4

" TO

1

2

" GAP

BETWEEN SIDING

AND FLASHING

END DAM

Florida Lath & Plaster Bureau (FLAPB) details are for

illustration of construction methods.They are to be used as

guidelines by the design and/or construction team. You

should consult with your design and/or construction

specialists for specific construction requirements. Some

modification may be required for specific project conditions

or to meet local building code. FLAPB makes no

representation as to the suitability of any detail for specific

use at any location on any project. A qualified, licensed

architect or engineer must be consulted to specify the

detail for any specific use at any location on a project.

DTL 24

LEGEND

SHEATHING, 'OSB', PLYWOOD, DENSGLASS

SELF ADHERED FLASHING

PLASTER ACCESSORY

DRAINAGE PLANE WATER RESISTANT BARRIER (WRB)

BOND BREAK WATER RESISTANT BARRIER (WRB)

SELF FURRING (SF) LATH

SCRATCH COAT

STUCCO

SILL SEAL

FOAM ORNAMENTALS

GALVANIZED METAL FLASHING