vg70 product training - ortus group · 2020. 8. 19. · beijing aeonmed co., ltd. vg70 product...

43
Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department

Upload: others

Post on 12-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Beijing Aeonmed Co., Ltd.

VG70 Product TrainingInternational Service Department

Page 2: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

1. Product Description

2. Product Configuration And Main Functions

3. Operation Guidance

4. Advantages of VG70

5. Practical Operation

6. Q & A

Contents

Page 3: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

1、The first turbine ventilator in China.2、With Invasive and Non-Invasive ventilation function.3、Can be used on Infant ,Children and Adults4、Approved by CFDA & CE5、Wide application in General ICU,RICU,EICU, and for intra-hospital transport

Product Description

Page 4: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

1、Screen

Product Configuration & Main Functions

Alarm Indicator

A/C Power Indicator

Battery Working /Charging Indicator

Mute Key

Navigator KnobUI Display

Page 5: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

2、Main Unit

Product Configuration & Main Functions

Expiration Valve

Expiration Valve LockNebulizer

Oxygen Sensor Storage Shell

Expiration Port

Inspiration Port

Page 6: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

2、Main Unit

Product Configuration & Main Functions

Power Switch

Handle

Equal potential TerminalDC Input

DC Fuse

Fan

Oxygen Input Port

Air Filter

Nurse Call

CO2 Sensor Connection Port

Internal Battery

Page 7: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

3、Trolley & Accessories

Product Configuration & Main Functions

Trolley

Humidifier

Test Lung

Breathing Circuits

Support Arm

Page 8: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、Main Function –Ventilation Modes (1)

Invasive Ventilation Modes:VCV, PCV, SIMV (V, P, PRVC), PRVC, SPONT/CPAP, BIVENT

Non - Invasive Ventilation Modes:NIV/CPAP, NIV-T, NIV-S/T

Product Configuration & Main Functions

Page 9: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Ventilation Modes (2)

Ventilation Strategy:

IV NIV

Weaning Parameter:RSBI(Rapid-Shallow Breathing Index) WOB(Work of breathing during lung)

Product Configuration & Main Functions

Page 10: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Alarm(1)

5.1 Sound/Light/Color , 3 kind of Indicators5.2 High level /Mid-LevelAnd low level 5.3 After disappearing the Alarm can be reviewed

Question:What will happen if many alarms Occur ?

As priority level

Product configuration and main function

Page 11: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Alarm(2)

Product configuration and main function

Page 12: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –MonitoringMany ways to monitor

Product configuration and main function

Page 13: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Parameter Setting(1) How to set ?

Product configuration and main function

Page 14: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(1)

Product configuration and main function

Inspiratory Hold

Page 15: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(2)

Product configuration and main function

Expiratory Hold

Page 16: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(3)

Product configuration and main function

Nebulizer

Page 17: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(4)

Product configuration and main function

Manual Trigger

Page 18: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(5)

Product configuration and main function

Suction

Page 19: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Auxiliary Function(6)

Product configuration and main function

Freeze

Page 20: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 21: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 22: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 23: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 24: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 25: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 26: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 27: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 28: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 29: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 30: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

4、 Main Function –Other Functions

Product configuration and main function

Page 31: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Daily disinfection of the surface of the ventilator.

Operational Guidance

Page 32: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Every 1-3 months,hospital maintenance staff should check the air filter and change it according to the situation of the surface of it.

Operational Guidance

Page 33: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Lifetime of oxygen Sensor is 1 year . If calibration failure ,please change a new one.

Paramagnetic Oxygen Sensor is not consumptiveMaterial

Operational Guidance

Page 34: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Disinfection of Expiration valve.

Operational Guidance

Page 35: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

When the ventilator is used to cure infectious diseases.Use a bacteria filter before Expiration valve.

Operational Guidance

bacteria filter

Page 36: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

VCV, PCV, SIMV (V, P, PRVC), PRVC,

SPONT/CPAP, BIVENT

NIV/CPAP, NIV-T, NIV-S/T

Advantages of VG70

Page 37: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Advantages of VG70

Page 38: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Ultra-quiet25000 h long-life turbine

safe in

oxygen

enrichment

Key parts

Advantages of VG70

Page 39: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

人机界面友好12”TFT touch

screen

Pre-set parameters

Complete monitoring parameters

Advantages of VG70

Page 40: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Synchronized triggering

Automatic Leakage

Compensation

E-ComfTM

expiration control

Advantages of VG70

Page 41: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

long-life expiratory

flow sensor

ParamagnetiCO2 sensor

upgradable software with USB

port

Advantages of VG70

Page 42: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

ParametersParameters SettingsTidal Volume: 20-2000mlRespiratory Rate: 1-80 bpm Inspiration Time:0.2-9sInspiration Pause Time: 0~4sTslope : 0~2sFiO2: 21%~100%PEEP: 0-35cmH2OCPAP(NIV): 2-20cmH2OPsupp: 0-70cmH2OPinsp: 5-70cmH2O Phigh(in BIVENT mode): 5-60cmH2OPlow(in BIVENT mode): 0-35cmH2OEsens: 5%~80%Trend function for multiple parametersParameter Controlld

Pressure: Pmin, Pplat, Pmean, Ppeak, PEEP

Volume:VTI, VTE, MV, Mvspont, Leak%

Curves: P-t, F-t, V-t , etCO2-t

Loops: P-V, P-F, F-V

Page 43: VG70 Product Training - Ortus Group · 2020. 8. 19. · Beijing Aeonmed Co., Ltd. VG70 Product Training International Service Department. 1. Product Description 2. Product Configuration

Q&A