Flows to 151 l/min (40 USgpm) — Pressures to 350 bar (5000 psi)
654Released 1/94
Vickers®
Servo Valves
SM4-40 Servovalves
Vickers, Incorporated 1994All Rights Reserved
Introduction
Vickers SM4-40 servovalves canprovide system closed loop control withexact positional accuracy, repeatablevelocity profiles, and predictable force ortorque regulation.
Typical applications include plasticinjection molding and blow moldingsystems, test and simulationequipment, die casting machines,hydraulic press brakes, animation andentertainment equipment, oil explorationvehicles, and lumber machinery.
Applications of the 350 bar (5000 psi)SM4-40 (-50 design) include automaticgage control (AGC), roll bend/rollbalance systems, plastic injectionmolding systems, test and simulationequipment, and hydraulic press brakes.
This model of the high performanceSM4 series offers a wide range of rated
flows from 76 to 151 l/min (20 to 40USgpm) at �p of 70 bar (1000 psi).
The SM4 is a two-stage, modulardesign, flow control valve which can bemanifold or subplate mounted. Thesymmetrical, dual coil, quad air gaptorque motor is integrally mounted to thefirst stage nozzle flapper pilot valve withsix screws. The second stage utilizes afour-way sliding spool and sleevearrangement with a mechanical nulladjust. Spool position is fed back to thefirst stage by means of a cantileverspring. An integral 35 micron (absolute)filter protects against contamination ofthe first stage.
An SM4 servovalve, used with ahydraulic cylinder, position transducer,and appropriate electronics, can provideinfinite cylinder position control to within0,025 mm (0.001 in) or better (depending
on component selection, length ofstroke, and load characteristics).
When applied with servo hydraulicmotors, tachometers, and appropriateelectronics, the SM4 provides infiniteproportional flow control for real-timevelocity/acceleration profiles that can beclosed loop error corrected to withinone-tenth of a revolution per minute.With appropriate pressure transducersor load cells, cylinders, and properelectronics in force control applications,the SM4 offers exact load pressure/forcecontrol and excellent system stabilitywith pressure and load to ±1% full scale.
The field-proven design of the SM4-40servovalve, combined with Vickersprecision manufacturing techniques,provides you with the optimum insystem control.
Features and Benefits� The wide range of SM4 flow
capabilities allows selection of thevalve size best suited for anapplication.
� The SM4-40 (-10 design) has a highstrength aluminum alloy second stagevalve body for lighter weight withrugged durability.
� The SM4-40 (-50 design) features aspecial stainless steel body and endcaps for operating pressures up to 350bar (5000 psi).
� The symmetrical, dual-coil, quad airgap, dry torque motor in Vickersservovalves, with its extremely fastresponse to input signals, can producehighly accurate control profiles.
� Higher frequency response —available on request — providesenhanced system bandwidth forcritical performance requirements.
� An integral 35 micron (absolute) filterprovides extra first stagecontamination protection.
� The spool and sleeve are hardenedstainless steel to minimize wear anderosion. The O-ring mounted sleeveeliminates spool binding and ensuressmooth operation.
� Customized spool lap and sleeveporting are available to provide thespecific flow control required forspecial applications.
� The SM4’s symmetrical designprovides inherently dependablemetering of control flow with minimumnull shifts. The result is moreconsistent machine operation.
� Viton* seals are standard.
� The flexibility of standardized portcircles, mounting patterns, andadapter manifolds makes Vickersservovalves a cost-effective choice forreplacing existing servovalves andenhancing existing systems.
� The SM4-40 features a simpleinterface to an available dual filtermodule that provides extra protectionagainst pilot contamination.
� Flushing valves are available that cangreatly reduce initial systemcontamination levels prior to SM4installation.
* Viton is a registered trademark of theDuPont Co.
1
Contents
Operating Data 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Curves 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model Code 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Dimensions 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SM4M(E) Mounting Subplates 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SM4A Adapter Manifolds 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SM4FV Flushing Valves 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SM4FM Filter Modules 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SM4CB Cross Port Bleed 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weights 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Additional Accessories 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Data 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cross Section of TypicalSM4-40 Servovalve
3
Operating Data
Flow and LeakageAll data is typical, based on actual testsat 70 bar (1000 psi) ∆p, 30 cST (141SUS), and 49°C (120°F).
Model Series
Maximum RatedFlow �10%l/min (USgpm)
Maximum TotalNull Leakagel/min (USgpm)
Maximum Pilot Flow at70 bar (1000 psi) ∆pl/min (USgpm)
SM4-40 (-10 design)151 (40) 3 48 (0 92) 0 9 (0 24)
SM4-40 (-50 design)151 (40) 3,48 (0.92) 0,9 (0.24)
PerformanceMaximum Supply Pressurebar (psi)
SM4-40 (-10 design): 210 (3000)SM4-40 (-50 design): 350 (5000)
Minimum Supply Pressurebar (psi)
14 (200)
Proof Pressure% maximum supply pressure
At Supply Port: 150At Return Port: 100
Burst Pressure, Return Port Open% maximum supply pressure
250
Maximum Operating Temperature°C (°F)
135 (275)
Hysteresis Around Null% of rated current
≤3
Symmetry Error% of rated current
<10
Linearity Error% of rated current
<10
Threshold% of rated current
≤0.5
Ruggedness Test ResultsVibration Test5 Hz to 2000 Hz along each axis
No damage to components
Shock TestUp to 150g along all axes
No damage to components
Endurance TestTo ISO 6404
No degradation in performance
4
Flow GainNormal region for standard modelsshown with typical no-load flow gaintolerances excluding hysteresis.
–100–100
% RATED CURRENT
% R
AT
ED
FLO
W
–80
–60
–40
–20
0
+20
+40
+60
+80
+100
–80 –60 –40 –20 0 +20 +40 +60 +80 +100
�5%
Flow tolerance �10%
–10–100
% INPUT CURRENT
% M
AX
IMU
M S
UP
PLY
PR
ES
SU
RE
–80
–60
–40
–20
0
+20
+40
+60
+80
+100
–8 –6 –4 –2 0 +2 +4 +6 +8 +10
To 100% rated
Pressure GainChange in load pressure drop with inputcurrent shown with no valve flow andclosed control ports.
Pressure gain in the null region is >30%of supply pressure per 1% of ratedcurrent.
200% nominal gain
50% nominal gain
5
00
PO
WE
R T
RA
NS
MIS
SIO
N E
FF
ICIE
NC
Y –
%
10
20
0.2 0.4
Power TransmissionEfficiencyMaximum power envelope expressed asa percentage with T port pressure equalto 0 bar.
Power transferred to the load is optimumwhen valve pressure drop is one third ofsupply pressure. Load pressure dropshould be limited to 2/3 of supplypressure so the flow gain of theservovalve remains high enough tomaintain control of the load. Overallhydraulic efficiency must be consideredwhen sizing system heat exchangers.
RATIO LOAD PRESSURE DROPSUPPLY PRESSURE
30
40
50
60
70
80
90
100
0.6 0.8 1.0
Change in Rated FlowRated flows at valve pressure drops from5 bar (70 psi) to 350 bar (5000 psi) forthe five available spools.
NO
-LO
AD
FLO
W R
AT
E –
l/m
in (
US
gpm
)
15 (4)19 (5)
27 (7)30 (8)
38 (10)
57 (15)
76 (20)95 (25)
114 (30)
SP
OO
L R
AT
ED
FLO
W –
(U
Sgp
m)
l/min
135 (35)151 (40) (20) 76
SM4-40 (-50 design) only
(40) 151(35) 132(30) 113(25) 95190 (50)
211 (55)228 (60)
350(5000)
5(70)
VALVE PRESSURE DROP (P→A)+(B→T) – bar (psi)
7(100)
14(200)
21(300)
35(500)
70(1000)
140(2000)
4 (1)
8 (2)
11 (3)
210(3000)
246 (65)
Electrical Polarity forControl Flow Out of B Port
Single:A+, B–orC+, D–
Series:A+, D–Connect B and C
+ –
Parallel:A+, C+B–, D–Connect A and CConnect B and D
Differential:A–, D–B+, C+Connect B and CBC–, current BA>CDBC+, current CD>BA – –+
A B C D
+ –
–+ –+
A B C D
A B C D
A B C D
Servovalve
Servovalve
Servovalve
Servovalve
6
Coil ResistanceSelect coil resistance and connectionsfor compatible interface to servoelectronics. Recommended coilresistance is shown in bold print.
Nominal ResistanceRated Current mA
Nominal ResistancePer Coil at 21°C (70°F)Ohms
Single, Parallel, orDifferential Connection Series Connection
20 200 100
Standard coil 30 100 50tandard coilresistance selection 80 40 20
200 20 10
80 50 25
140 40 20
Optional coil 200 15 7.5O tional coilresistance selection 300 30 15
1000 10 5
1500 8 4
Calculating Frequency Responseat System PressurePS = System pressurePM = Maximum supply pressure of
valve: 210 bar (3000 psi) forSM4-40 and 350 bar(5000 psi) for SM4-40 (-50 design)
fPM= Frequency (at 90° phase angle) atmaximum supply pressure (PM)
fPS = Frequency (at 90° phase angle) atsystem pressure (PS)
1. Calculate the ratio of systempressure to maximum supplypressure:
2. Use the result of step 1 and thecurve below to estimate
3. Use the applicable frequencyresponse curve from the followingpages to estimate fPM (the maximumsupply pressure frequency responseat 90° phase angle) for the desiredvalve.
4. Multiply the values obtained in steps2 and 3. The result is fPS (systempressure frequency response at 90°phase angle).
Frequency ResponseFrequency response is defined as therelationship of no-load control flow toinput current with a sinusoidal currentsweep at constant amplitude over arange of frequencies. It is expressed infrequency (Hz), amplitude ratio (dB),and phase angle (degrees).
As shown in the sample curve (belowleft), standard comparison points forservovalve frequency response arethose frequencies at which –3 dBamplitude ratio and 90° phase angleoccur.
Vickers SM4 torque motors aremagnetically stabilized for reliableservovalve performance at operatingpressures from 14 to 350 bar (200 to5000 psi).
Example: A standard performanceSM4-40 (-10 design) valve with a flow of95 l/min (25 USgpm) is to be used at165 bar (2400 psi).
1. Calculate the ratio of systempressure to maximum supplypressure:
2. Use the result of step 1 and thecurve below right to estimate
3. Use the frequency response curvefrom page 7 to estimate fPM.
4. Multiply the values obtained in steps2 and 3. The result is fPS (systempressure frequency response at 90°phase angle).
0 0.2
1.0
0.8
0.6
0.40.4 0.6 1.00.8
PS (system pressure)
PM (maximum supply pressure)
fPSfPM
Phase lag(shift)
7 10 20 30 40 50 70 100
0
–5
–10
FREQUENCY – Hz
AM
PLI
TU
DE
RA
TIO
– d
B
PH
AS
E A
NG
LE –
deg
rees
120
90
–15
–20
200 300 400 500
100
80
70
60
50
40
30
20
10
110
–3dB comparison point
0.9
0.7
0.5
0.1 0.3 0.5 0.90.7
PS
PM
fPS
fPM
PS
PM�
2400 psi3000 psi
� 0.8
fPS
fPM� 0.92
fPM � 42 Hz
fPS � 0.92 � 42 Hz � 39 Hz
7
Performance Curves
Rise timesat 63% flow
0 10 200
TIME – ms
OU
TP
UT
FLO
W %
100
20
40
60
80
Settling timesto 5% accuracy
Critically damped valve
Underdamped valve
5 15
120
3 10 20 30 40 50 70 100
0
–5
–10
FREQUENCY – Hz
AM
PLI
TU
DE
RA
TIO
– d
B–15
–20
–25
PH
AS
E L
AG
– d
egre
es
90
100
80
70
60
50
40
30
20
10
�40% rated current
2004 5 7
113 l/min (30 USgpm)132 l/min (35 USgpm)151 l/min (40 USgpm)
76 l/min (20 USgpm)95 l/min (25 USgpm)
3 10 20 30 40 50 70 100
0
–5
–10
FREQUENCY – Hz
AM
PLI
TU
DE
RA
TIO
– d
B
–15
–20
–25
–30
PH
AS
E L
AG
– d
egre
es90
100
80
70
60
50
40
30
20
10
�40% rated current
�100% rated current
2004 5 7
Typical Frequency Response CurvesSM4-40 (-10 and -50 designs) shownat 210 bar (3000 psi)
Step ResponseStep response is defined as the typicalrise time needed to achieve a givenpercentage of control flow output.Settling time is the time needed fortransient flow fluctuations to diminish towithin a given accuracy range. Both areexpressed in milliseconds (ms).
The example at right shows the stepresponse curves for a critically dampedvalve and an underdamped valve. Risetimes are illustrated for 63% of controlflow output, and settling times areshown at 100±5% of control flow output.
8
76 l/min (20 USgpm)95 l/min (25 USgpm)
OU
TP
UT
FLO
W %
100
20
40
60
80
120
0
76 l/min (20 USgpm)
95 l/min (25 USgpm)
0 10 20
TIME – ms
5 15 25
113 l/min (30 USgpm)
OU
TP
UT
FLO
W %
100
20
40
60
80
120
00 10 20
TIME – ms
5 15 25
OU
TP
UT
FLO
W %
100
20
40
60
80
120
00 10 20
TIME – ms
5 15 25
132 l/min (35 USgpm)151 l/min (40 USgpm)
132 l/min (35 USgpm)
151 l/min (40 USgpm)
Typical Step Response Curves forStandard ModelsSM4-40 (-10 and -50 designs) shownat 210 bar (3000 psi)
9
10
Model Code
3 4 5 61 2
1
2
Series designation
SM4 – Servovalve, high performance,four-way
Valve size
40 – 44,5 mm (1.75 in) port circle
Flow rating
At 70 bar (1000 psi) �p P→A→B→T.Other flows available on request.
Code USgpm l/min(20) 76 20.0 76(25) 95 25.0 95(30) 113 30.0 113(35) 132 35.0 132(40) 151 40.0 151
3
4
5
6Coil resistance/rated current
Ohms/mA at 21°C (70°F). Other coilsavailable on request.
Code Ohms mA20/200 20 20030/100 30 10080/40 80 4080/50 80 50140/40 140 40200/15 200 15200/20 200 20300/30 300 301000/10 1000 101500/8 1500 8
Design number
Subject to change. Installationdimensions same for designs 10 through19 and for designs 50 through 59.
10 to 19 – 210 bar (3000 psi) maximum supply pressure
50 to 59 – 350 bar (5000 psi) maximumsupply pressure
Special features suffix
S81 – Intrinsically safe valve (-10design only). Contact yourVickers representative fordetails.
S*** – Vickers assigns a unique suffixto denote a particular group ofspecial features. Contact yourVickers representative fordetails.
Blank– Standard valve
millimeters (inches)
38,18(1.50)
38,18(1.50)
54,8(2.16)
60,00(2.36)
60,00(2.36)
72,70(2.86)
72,70(2.86)
Electrical connector mateswith MS-3106-14S-2S (4 pin).Plus signal to A or C causesflow out of port B.
Null adjust(Do not loosen locknut)
3,00(0.12)∅
8,33(0.33)
4 places
∅
22,00(0.87)4 places
∅ 14,50(0.57)4 places
∅
∅ 44,46(1.75)
∅ 15,82(0.62) optional 5th port
counterbore
port circle
port
36,50(1.44)
19,02(0.75)max.
85,66(3.37) 69,90
(2.75)
2,00(0.08)
40,40(1.59)
60,32(2.37)
30,16(1.19)
20,63(0.81)
20,63(0.81)
22,23(0.875)
46,04(1.81)
92,08(3.63)
25,00(0.98)
NOTESTorque mounting screws to 22 to 27 Nm (190to 240 lb.in.).
Valve mounting surface requires 63 microinchfinish flat within 0,05 (0.002).
Viton port O-rings (AS568-018) provided:1,78 (0.070) cross section and 18,77 (0.739)inner diameter. Replacement O-ringsavailable in seal kit 920321 only.
85,90(3.38)
101,40(3.99)
44,78(1.76)
Locating pin
Valve can be orderedwith connectorpositioned over any port
11
Installation Dimensions
12
SM4M(E) Mounting Subplates
Series designation
SM4 – Servovalve, high performance,four-way
Accessory designation
M – Mounting subplate. Maximumsupply pressure of 210 bar (3000psi), except -5* designs withmaximum supply pressure of 350bar (5000 psi).
Port connection locations
Blank – Rear portsE – Side ports
Standard SM4 valve size
40 – SM4-40
3 4 5 61 2
Model Code
1
2 4
6
Design number
Subject to change. Installationdimensions same for designs 10 through19 and for designs 50 through 59.
10 to 19 – 210 bar (3000 psi) maximum supply pressure
50 to 59 – 350 bar (5000 psi) maximumsupply pressure
Metric suffix
M – Metric version to NG (ISO)standards
Blank – Omit if not required
53
22,00(0.87)
3,00(0.12)
SM4M-40-10/50(M)
7,14(0.28)4 places
∅ thru
10,31(0.41)4 places
∅ counterbore
4,00(0.16)∅
46,04(1.81)
92,08(3.62) 6,30
(0.25)
30,16(1.19)
60,32(2.37)
6,30(0.25)
M8 x 80 thd. (metric).312-18 UNC-2B thd. (inch)4 places
8,71(0.34)4 places
∅ port
127,0(5.00)
63,5(2.50)
∅ 66,00(2.60)port circle
19,05 (0.75) O.D. tubeG3/4 (metric)1.0625-12 UNC-2B thd. (inch)4 places
50,8(2.00)
6,35(0.25)
16,0(0.63)
114,4(4.50)
57,2(2.25)
Installation Dimensionsmillimeters (inches)
20,63(0.81)
20,63(0.81)
∅ 44,46(1.75) port circle
6,35 (0.25) O.D. tubeG1/4 (metric).4375-20 UNF-2B thd. (inch)Optional external pilot pressure port
20,00(0.79)
3,18(0.125)Ext. pilot
∅
13
SM4ME-40-10/50(M)
7,14(0.28)4 places
∅ thru
10,31(0.41)4 places
∅ counterbore
4,00(0.16)∅
20,63(0.81)
20,63(0.81)
20,00(0.79)
6,30(0.25)
22,00(0.87)
6,30(0.25)
∅ 44,46(1.75) port circle
M8 x 80 thd. (metric).312-18 UNC-2B thd. (inch)4 places
8,71(0.34)4 places
∅ port
127,0(5.00)
63,5(2.50)
50,8(2.00)
3,00(0.12)
6,35(0.25)
16,0(0.63)
114,4(4.50)
57,2(2.25)
19,05 (0.75) O.D. tubeG3/4 (metric)1.0625-12 UNC-2B thd. (inch)4 places
25,40(1.00)
33,00(1.30)
30,16(1.19)
60,32(2.37)
46,04(1.81)
92,08(3.62)
6,35 (0.25) O.D. tubeG1/4 (metric).4375-20 UNF-2B thd. (inch)Optional external pilot pressure port
14
15
SM4A Adapter Manifolds
Model Code
1
2
Series designation
SM4 – Servovalve, high performance,four-way
Accessory designation
A – Adapter manifold. Maximum supplypressure of 210 bar (3000 psi),except -5* designs with maximumsupply pressure of 350 bar (5000psi).
4
6
Interface
8 – ISO 4401-08
Standard SM4 valve size
40 – SM4-40
Design number
Subject to change. Installationdimensions same for designs 10 through19 and for designs 50 through 59.
10 to 19 – 210 bar (3000 psi) maximum supply pressure
50 to 59 – 350 bar (5000 psi) maximumsupply pressure
Metric suffix
M – Metric version to NG (ISO)standards
Blank – Omit if not required
53
3 4 5 61 2
130,20(5.13)
76,97(3.03)
88,10(3.47)
46,05(1.81)
53,18(2.09)
92,10(3.63)
22,23(0.88)
20,65(0.81)
30,15(1.19)
57,15(2.25)
60,30(2.37) 25,00
(0.98)
92,08(3.63)
46,04(1.81)
20,65(0.81)
4,00(0.16)
Ext. pilot
∅
M8 x 50 thd. (metric).3125-18 UNC-2C thd. (inch)4 places
∅ 44,45(1.75) port circle
4,00(0.16)∅
∅ 14,30(0.56) P and T ports
20,00(0.79)6 places
∅ counterbore
∅ 12,00(0.47) A and B ports
13,50(0.53)6 places
∅
114,30(4.50)
57,15(2.25)
50,80(2.00)
13,50(0.53)
13,80(0.54)
152,40(5.92)
15,90(0.63)
3,00(0.19)
6,25(0.25)
6,35(0.25)
112,70(4.44)
94,46(3.72)
76,90(3.03)
29,36(1.16)
96,80(3.81) 73,03
(2.88) 17,60(0.69)
74,60(2.94)
19,05(0.75)
100,80(3.97)
53,16(3.03)
25,23(0.99)2 places
∅ counterbore
23,00(0.91)4 places
∅ port15,50(0.61)∅ 5th port
17,40(0.69)
33,33(1.31)4 places
∅ counterbore
Installation Dimensionsmillimeters (inches)
thru
SM4A-8-40-10/50(M)
16
17
SM4FV Flushing Valves
Model Code
1 Series designation
SM4 – Servovalve, high performance,four-way
Accessory designation
FV– Flushing valve. Maximum flushingpressure of 35 bar (500 psi).
Standard SM4 valve size
40 – SM4-40
Design number
Subject to change. Installationdimensions same for designs 10 through19.
3 41 2
3
2 4
Installation Dimensionsmillimeters (inches)
127,00(5.00)
89,00(3.50)
44,50(1.75)
63,50(2.50)
92,08(3.63)
17,50(0.69)
60,32(2.37)
14,30(0.56)
40,00(1.57)
25,00(0.98)
8,33(0.33)4 places
∅ thru
SM4FV-40-10
18
SM4FM Filter Modules
Accessory designation
FM – Filter module. Maximum supplypressure of 210 bar (3000 psi),except -5* designs with maximumsupply pressure of 350 bar (5000psi).
Standard SM4 valve size
40 – SM4-40
3
Model Code
1 Series designation
SM4 – Servovalve, high performance,four-way
Design number
Subject to change. Installationdimensions same for designs 10 through19 and for designs 50 through 59.
10 to 19 – 210 bar (3000 psi) maximum supply pressure
50 to 59 – 350 bar (5000 psi) maximumsupply pressure
3 41 2
42
Installation Dimensionsmillimeters (inches)
92,08(3.63)
46,04(1.81)
60,00(2.36)
20,63(0.81)
120,00(4.72)
20,63(0.81)
30,16(1.19)
60,32(2.37)
38,15(1.50)
88,50(3.48)
96,0(3.8)
122,0(4.8)
3,06(0.12)
2,00(0.08)
∅ 44,46(1.75) port circle
8,33(0.33)4 places
∅ thru
21,98(0.87)4 places
∅ counterbore
14,5(0.57)4 places
∅ port
SM4FM-40-10/50 19,00(0.75)
19
SM4CB Cross Port Bleed Modules
Accessory designation
CB – Cross port bleed module. Includescross port bleed feature betweenports A and B. Maximum supplypressure of 210 bar (3000 psi),except -5* designs with maximumsupply pressure of 350 bar (5000psi).
Standard SM4 valve size
40 – SM4-40
3
Model Code
1 Series designation
SM4 – Servovalve, high performance,four-way
Design number
Subject to change. Installationdimensions same for designs 10 through19 and for designs 50 through 59.
10 to 19 – 210 bar (3000 psi) maximum supply pressure
50 to 59 – 350 bar (5000 psi) maximumsupply pressure
3 41 2
42
20
Installation Dimensionsmillimeters (inches)
20,63(0.81)
20,63(0.81)
3,00(0.12)
2,00(0.08)
∅ 44,46(1.75) port circle
21,98(0.87)4 places
∅ counterbore14,50(0.57)4 places
∅ port
SM4CB-40-10/50 92,08(3.63)
46,04(1.81)
60,00(2.36)
20,63(0.81)
120,00(4.72)
20,63(0.81)
30,16(1.19)
60,32(2.37)
38,10(1.50)
76,20(3.00)
∅ 44,46(1.75) port circle
8,33(0.33)4 places
∅ thru
14,50(0.57)4 places
∅ port
19,00(0.75)
4,00(0.16)∅
NOTEViton port O-rings (AS568-018) provided:1,78 (0.070) cross section and 18,77 (0.739)inner diameter.
21
13Weights
The following table lists approximate dryweights for SM4-40 servovalves andrelated accessories.
Description Model CodeWeightkg (lbs.)
Servov lveSM4-40 (-10 design) 2,8 (6.2)
ServovalveSM4-40 (-50 design) 5,0 (11.0)
Mo nting s bpl teSM4M(E)-40-10(M) 1,8 (4.0)
Mounting subplateSM4M(E)-40-50(M) 5,0 (11.0)
Ad pter m nifoldSM4A-8-40-10(M) 2,013 (4.44)
Adapter manifoldSM4A-8-40-50(M) 5,0 (11.0)
Flushing valve SM4FV-40-10(M) 0,77 (1.70)
Filter mod leSM4FM-40-10(M) 1,38 (3.04)
Filter moduleSM4FM-40-50(M) 1,4 (3.1)
Cross port bleed mod leSM4CB-40-10 0,60 (1.32)
Cross port bleed moduleSM4CB-40-50 1,70 (3.74)
14Additional AccessoriesSM4-40 Accessories Model Code
Valve mounting bolt kit (inch) 5/16–18 x 3” BK866689
Valve mounting bolt kit (metric) M8 x 80mm BK689628M
Subplate mounting bolt kit (inch) 1/4–20 x 21/4” BK866685
Subplate mounting bolt kit (metric) M6 x 60mm BK689623M
Adapter manifold mounting bolt kit (inch) 1/2–13 x 21/4” BK855990
Adapter manifold mounting bolt kit (metric) M12 x 60mm BK855991M
Flushing valve mounting bolt kit (inch) 5/16–18 x 11/2” BK927862
Flushing valve mounting bolt kit (metric) M8 x 40mm BK927863M
Filter module mounting bolt kit (inch) 5/16–18 x 33/4” BK916140
Filter module mounting bolt kit (metric) M8 x 100mm BK916141M
Filter kit (valve) 926470
Filter kit (filter module) 916277
Cable connector (MS3106-14S-2S) 242123
Cable clamp (MS3057-6) 126058
Seal kit 920321
22
Servo ElectronicsSee application brochure 656 for thecomplete Vickers line of amplifiers,power supplies, and function modules.
Application DataFluid CleanlinessProper fluid condition is essential forlong and satisfactory life of hydrauliccomponents and systems. Hydraulicfluid must have the correct balance ofcleanliness, materials, and additives forprotection against wear of components,elevated viscosity and inclusion of air.
Essential information on the correctmethods for treating hydraulic fluid isincluded in Vickers publication 561“Vickers Guide to SystemicContamination Control,” available fromyour local Vickers distributor or bycontacting Vickers, Incorporated.Recommendations on filtration and the
selection of products to control fluidcondition are included in 561.
Recommended cleanliness levels, usingpetroleum oil under common conditions,are based on the highest fluid pressurelevels in the system and are coded inthe chart below. Fluids other thanpetroleum, severe service cycles, ortemperature extremes are cause foradjustment of these cleanliness codes.See Vickers publication 561 for exactdetails.
Vickers products, as any components,will operate with apparent satisfaction influids with higher cleanliness codes thanthose described. Other manufacturers
will often recommend levels abovethose specified. Experience has shown,however, that life of any hydrauliccomponent is shortened in fluids withhigher cleanliness codes than thoselisted below. These codes have beenproven to provide a long, trouble-freeservice life for the products shown,regardless of the manufacturer.
NOTEVickers will extend, by one year, thestandard warranty on all Vickersproducts used in a system protectedby Vickers filters (and elements)applied in a manner consistent withthe principles presented in Vickerspublication 561.
System Pressure Levelpsi
Product <2000 2000–3000 3000+
Vane pumps, fixed 20/18/15 19/17/14 18/16/13
Vane pumps, variable 18/16/14 17/15/13
Piston pumps, fixed 19/17/15 18/16/14 17/15/13
Piston pumps, variable 18/16/14 17/15/13 16/14/12
Directional valves 20/18/15 20/18/15 19/17/14
Proportional valves 17/15/12 17/15/12 15/13/11
Servo valves 16/14/11 16/14/11 15/13/10
Pressure/Flow controls 19/17/14 19/17/14 19/17/14
Cylinders 20/18/15 20/18/15 20/18/15
Vane motors 20/18/15 19/17/14 18/16/13
Axial piston motors 19/17/14 18/16/13 17/15/12
Printed in U.S.A.Rel. 1/94 – HH
Form No. 00-000 Copyright Eaton Corporation, 0000All rights reserved.Printed in U.S.A
Eaton Hydraulics15151 Highway 5Eden Prairie, MN 55344Telephone: 612 937-7254Fax: 612 937-7130www.eatonhydraulics.com