virtus®ii module - enf solar · virtus®ii module safety fire mechanical load capability of up to...

2
Virtus®II Module Safety Fire Mechanical Load Capability of up to 5400 Pa Applicaon Class A, Safety Class II, Fire Rang C ISO9001, OHSAS18001, ISO14001 Cerfied Conforms with IEC 61215:2005, IEC 61730:2004, UL1703 PV Standards Easy Installaon and Handling for Various Applicaons High Module Conversion Efficiencies ReneSola.com Guarantee linear power output material & workmanship 100% 95% 90% 85% 80% 0% 25 80,0% 0 1 97,5% 5 10 15 20 Performance Figures in % Added Value YEAR 305W, 310W, 315W, 320W U L US C LISTED C US Intertek CM TUV NORD CERT GmbH IEC6 121 5/ 6173 0-1/61730 -2

Upload: nguyendang

Post on 18-Sep-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Virtus®II Module

Safety Fire

Mechanical Load Capability of up to 5400 Pa

Application Class A, Safety Class II, Fire Rating C

ISO9001, OHSAS18001, ISO14001 Certified

Conforms with IEC 61215:2005,IEC 61730:2004, UL1703 PV Standards

Easy Installation and Handling for Various Applications

High Module Conversion Efficiencies

ReneSola.com

Guarantee

linear poweroutput

material &workmanship

100%

95%

90%

85%

80%

0%25

80,0%

0 1

97,5%

5 10 15 20

Per

form

ance

Fig

ures

in %

Added Value

YEAR

305W,310W, 315W, 320W

UL USC

LISTEDC US

Intertek

CM

TUV NORD CERTGmbH

IEC 61215 / 61730-1 / 61730-2

Container

Pallets per Container

Pieces per Container

20’ GP

10

250/260

40’ HQ

24

660/684

40’ GP

24

600/624

Cell Type

Glass

Frame

Dimension

Output Cable

Weight

Virtus II (Polycrystalline) 156 x156 mm, 72 (6x12) pcs in series

High Transmission, Low lron, Tempered Glass

Anodized Aluminum Alloy

IP65/IP67 Rated, With Bypass Diodes

*1956 x 992 x 40 mm

4 mm2 (EU)/12 AWG (US), 1200 mm

27 kg

See Drawing Above

-40oC ~ +85oC

1000VDC (EU) / 1000VDC (US)

20A (EU) / 20A (US)

Temperature Coefficient of Voc

Temperature Coefficient of Isc

Temperature Coefficient of Pmax

JC310M-24/Abs

310 W

0 ~ +5W

16.0%

8.38 A

37.0 V

8.80 A

45.0 V

JC310M-24/Abs

230 W

6.80 A

33.8 V

7.10 A

42.1 V

Maximum Power (Pmax)

Power Tolerance

Module Efficiency

Maximum Power Current (lmp)

Maximum Power Voltage (Vmp)

Short Circuit Current (lsc)

Open Circuit Voltage (Voc)

Maximum Power (Pmax)

Maximum Power Current (lmp)

Maximum Power Voltage (Vmp)

Short Circuit Current (lsc)

Open Circuit Voltage (Voc)

Virtus®II Module

40mm

Drawing Only for Reference

-0.30%/oC

0.04%/oC

-0.40%/oC

45oC 2oC+_

ReneSola.com

Cur

rent

(A)

Voltage(V)

1176

mm

1676

mm

1200

mm

947mm

JUNCTION BOX

LABEL

16-8X3.5

2-Ø4

INSTALLING HOLE

VENT HOLE

GROUNDING HOLE

4-7.5X7.5/2DRAIN HOLE

8-6.5X10

Junction Box

Installation Hole Location

Nominal Operating Cell Temperature (NOCT)

Operating Temperature

Maximum System Voltage

Maximum Series Fuse Rating

Rev No: JC/TDS/2015.01.20 *Contact Renesola for tolerance specificationCAUTION: All rights reserved. Design and specification are subject to change without prior notice.

305W\310W\315W\320W

992mm

1956

mm

JC315M-24/Abs

315 W

0 ~ +5W

16.2%

8.45 A

37.3 V

8.88 A

45.4 V

JC315M-24/Abs

234 W

6.88 A

34.0 V

7.16 A

42.5 V

Values at Standard Test Conditions STC (AM1.5, Irradiance 1000W/m2, Cell Temperature 25oC)

Values at Normal Operating Cell Temperature, Irradiance of 800W/m2, AM1.5, Ambient Temperature 20oC, Wind Speed 1m/s.

JC320M-24/Abs

320 W

0 ~ +5W

16.5%

8.56 A

37.4 V

9.00 A

45.6 V

JC320M-24/Abs

238 W

6.96 A

34.2 V

7.26 A

42.7 V

0 10 20 30 40 500

2

4

6

8

10

200W/m2

400W/m2

600W/m2

800W/m2

1000W/m2

JC305M-24/Abs

305 W

0 ~ +5W

15.7%

8.33 A

36.6 V

8.73 A

44.9 V

JC305 M-24/Abs

226 W

6.72 A

33.6 V

7.04 A

42.0 V