visio-3940472 t01

14
5113003

Upload: others

Post on 31-May-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Visio-3940472 T01

5113003

Page 2: Visio-3940472 T01

AGS

Power supply

Voltage: 400 VACPhases: 3Frequency: 50 HzCurrent: 6 AShort-circuit capacity 10 kA

Page 3: Visio-3940472 T01

AGS

CE marking location

The CE marking is located on the outside of the door, in the upper left corner.

Electricians

Electricians must have:Experience from similar installationsSufficient knowledge to work from drawings and wiring diagramsKnowledge of local safety regulations for electrical power and automationKnowledge in english language

To avoid risks, only experienced personnel with technical knowledge and experience may perform repair work on the machine's electronics components.

Application of usage

The Control box is to be used for controlling FlexLink Guide units without or in combination with FlexLink Junction boxes.

The Control box should not be used for any other purpose than controlling FlexLink Guide rails.

Safety

The voltage in the control box is 400V for Europe or 480V for US. Ensure that the control box is closed and locked after working in the control box.

The control box door can only be opened using a tool.

Only authorised personnel may open electrical units.Incorrect use of the equipment can cause personal injury.Do not stand or climb on the equipment.Only use recommended spare parts.Before working in the control box, the main switch must be turned off and locked.

Assembly

The box is equipped with two aluminium beams on the backside to facilitate mechanical assembly.

Installation

The incoming power supply should be connected to the main switch, Q30102. Protective earth should be connected to PE terminal.

Electrical supply data, Europe-versions:Voltage: 400 VACPhases: 3Frequency: 50 HzCurrent: 6 AShort-circuit capacity: 10 kA

Electrical supply data, US-versions: Voltage: 460-480 VACPhases: 3Frequency: 60 HzCurrent: 4 AShort-circuit capacity: 200 kA

Note: Additional 24VDC power supply is necessary for "automatic setting" versions (Type 2). Reference to electrical documentation for 24VDC and fieldbus connection.

Connect the Guide unit's included cable to connector X31103 or X31104.

Instruction for use

Note: Applicable for Control box, Type 1 (Manual setting).

The 3-position switch on the door is used for manually adjusting the Guide units' track width (distance between guide rails).

Turn left: Runs guide rails inwards0-position: 0Right position: Runs guide rails outwards

The motors are not automatically interlocked and stopped when reaching end-position.

Page 4: Visio-3940472 T01

EC Declaration of Conformity _________________________________________________________________________

FlexLink Components AB Flexlink Components AB

______________________ ________________________

Svante Anderholm Anders Jonsson Chief Operating Officer Responsible Technical file

_________________________________________________________________________ FlexLink Components AB

Telephone: +46-31-337 31 00 SE-415 50 Göteborg Fax: +46-31-337 22 33 Sweden

www.flexlink.com

FlexLink Components AB SE-41550 Göteborg Sweden declares that the following product(s) is in line with the essential requirements of the below directive(s)

• AGS Control box 5113439

Corresponding EC directives: Low Voltage Directive 2006/95/EC

According to 2004/108/EC Electromagnetic Compatibility Directive (EMC), the listed device is not indepentently operable product, but intended as part of a given fixed installation. Compliance of the directive requires the correct installation of the product, the observance of specific installation notes and product documentation.

Page 5: Visio-3940472 T01
Page 6: Visio-3940472 T01
Page 7: Visio-3940472 T01
Page 8: Visio-3940472 T01
Page 9: Visio-3940472 T01
Page 10: Visio-3940472 T01
Page 11: Visio-3940472 T01
Page 12: Visio-3940472 T01
Page 13: Visio-3940472 T01
Page 14: Visio-3940472 T01

Spar

e pa

rts

list C

ontr

ol b

ox 5

1134

39P

osD

esN

ame

Man

ufac

ture

rM

anuf

actu

rer i

tem

nr

Qty

Com

men

t

S31

203

Sw

itch

Moe

ller E

lect

ric21

6872

S31

203

Fixi

ng a

dapt

erM

oelle

r Ele

ctric

2163

74S

3120

3C

onta

ct e

lem

ent

Moe

ller E

lect

ric21

6376

Q31

002

Min

iatu

re c

ircui

t bre

aker

Mer

lin G

erin

C60

N 1

P C

6AQ

3100

3M

inia

ture

circ

uit b

reak

erM

erlin

Ger

inC

60N

1P

C6A

Q31

004

Min

iatu

re c

ircui

t bre

aker

Mer

lin G

erin

C60

N 1

P C

6AQ

3100

5M

inia

ture

circ

uit b

reak

erM

erlin

Ger

inC

60N

1P

C6A

Q31

006

Min

iatu

re c

ircui

t bre

aker

Mer

lin G

erin

C60

N 1

P C

6AQ

3100

7M

inia

ture

circ

uit b

reak

erM

erlin

Ger

inC

60N

1P

C6A

Q31

103

Min

iatu

re c

ircui

t bre

aker

Mer

lin G

erin

C60

N 1

P C

6AQ

3110

5M

inia

ture

circ

uit b

reak

erM

erlin

Ger

inC

60N

1P

C6A

Q31

203

Min

iatu

re c

ircui

t bre

aker

Mer

lin G

erin

C60

N 1

P C

6A

T311

03Tr

ansf

orm

erFl

exLi

nk50

5859

3T3

1103

Fuse

Littl

efus

e1A

, 5x2

0mm

T311

05Tr

ansf

orm

erFl

exLi

nk50

5859

3T3

1105

Fuse

Littl

efus

e1A

, 5x2

0mm

K31

104

Rel

ayFi

nder

40.5

1.8.

024

K31

104

Rel

ay s

ocke

tFi

nder

95.0

5.S

MA

K31

106

Rel

ayFi

nder

40.5

1.8.

024

K31

106

Rel

ay s

ocke

tFi

nder

95.0

5.S

MA

X31

103

Con

nect

orW

iela

nd96

.031

.105

3.1

X31

104

Con

nect

orW

iela

nd96

.031

.105

3.1