vmax_ss

4
SPECIFICATION SHEET The EMC ® Virtual Matrix Architecture is a new way to build storage systems that transcends the physical constraints of all existing architectures by scaling system resources through common building blocks called EMC Symmetrix ® VMAX engines. A single VMAX engine provides the complete foundation for a high-availability Symmetrix VMAX system. Each VMAX engine contains two Symmetrix VMAX directors and redundant interfaces to the EMC Virtual Matrix interconnect. Each Symmetrix VMAX director consolidates front-end, global memory, and back-end functions, enabling direct memory access to data for optimized I/O operations. VMAX engines are interconnected via a set of multiple active fabrics that provides scalable performance and high availability. VMAX engines can be added non-disruptively to provide linear scale-out of Symmetrix system resources. The Virtual Matrix is architected to scale to dozens of engines, geographi- cally dispersed throughout a data center, delivering unprecedented scale of infrastructure services under a single point of management. VMAX ENGINE MAXIMUM SPECIFICATIONS • Four Quad-core 2.33 GHz Intel ® Xeon ® processors • Up to 128 GB of memory • Virtual Matrix bandwidth: 24 GB/s VMAX MAXIMUM SYSTEM SPECIFICATIONS • Eight VMAX engines • 1 TB of memory • Virtual Matrix bandwidth: 192 GB/s VMAX INTERCONNECT • Industry-standard RapidIO ® fabric (Virtual Matrix Architecture is extensible to other standard interconnects.) CONNECTIVITY Symmetrix VMAX systems are available in configurations supporting up to eight VMAX engines with a maximum of 128 front-end ports. Optimized hardware logic and data protection encoding ensures end-to-end data integrity with automated channel failover for maximum availability and load balancing. Symmetrix VMAX systems support all popular hardware and operating system platforms, storage area networks (SANs), and high-availability cluster environments. IPv6, IPsec, and compression support are available with GigE ports. IPv6 support is available with 10 Gb/s Ethernet. PROTOCOL USABLE SYSTEM PORTS 8 Gb/s Fibre Channel Host/SAN Ports 4–128 per array, 4–16 ports per VMAX engine 8 Gb/s Fibre Channel Remote Replication Ports 2–32 per array, 2–4 ports per VMAX engine 8 Gb/s FICON Host Ports 4–64 per array, 4–8 ports per VMAX engine 4 Gb/s Fibre Channel Host/SAN Ports 4–128 per array, 4–16 ports per VMAX engine 4 Gb/s Fibre Channel Remote Replication Ports 2–32 per array, 2–4 ports per VMAX engine 4 Gb/s FICON Host Ports 4–64 per array, 4–8 ports per VMAX engine 10 Gb/s 10 GigE Remote Replication Ports 2–32 ports per array, 2–4 ports per VMAX engine 10 Gb/s FCoE Host Ports 4–64 ports per array, 4–8 ports per VMAX engine 10 Gb/s iSCSI Host Ports 4–64 ports per array, 4–8 ports per VMAX engine 1 Gb/s GigE Remote Replication Ports 2–32 ports per array, 2–4 ports per VMAX engine 1 Gb/s iSCSI Ports 4–64 per array, 4–8 ports per VMAX engine Mixed combinations of the above port types depend upon the configuration. Refer to the EMC Support Matrix at www.EMC.com, or contact your local EMC sales representative for specific configuration support. EMC SYMMETRIX VMAX STORAGE SYSTEM

Upload: muthu-kumaran-loganathan

Post on 11-May-2017

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: vmax_ss

s p e c i f i c a t i o n s H e e t

The EMC® Virtual Matrix Architecture™ is a new way to build storage systems that transcends the physical constraints of all existing architectures by scaling system resources through common building blocks called EMC Symmetrix® VMAX™ engines.

A single VMAX engine provides the complete foundation for a high-availability Symmetrix VMAX system. Each VMAX engine contains two Symmetrix VMAX directors and redundant interfaces to the EMC Virtual Matrix™ interconnect. Each Symmetrix VMAX director consolidates front-end, global memory, and back-end functions, enabling direct memory access to data for optimized I/O operations.

VMAX engines are interconnected via a set of multiple active fabrics that provides scalable performance and high availability. VMAX engines can be added non-disruptively to provide linear scale-out of Symmetrix system resources. The Virtual Matrix is architected to scale to dozens of engines, geographi-cally dispersed throughout a data center, delivering unprecedented scale of infrastructure services under a single point of management.

VMaX engine MaXiMuM specifications• FourQuad-core2.33GHzIntel® Xeon® processors• Upto128GBofmemory• VirtualMatrixbandwidth:24GB/s

VMaX MaXiMuM systeM specifications• EightVMAXengines• 1TBofmemory• VirtualMatrixbandwidth:192GB/s

VMaX interconnect• Industry-standardRapidIO® fabric (Virtual Matrix Architecture is extensible to other standard interconnects.)

connectiVitySymmetrix VMAX systems are available in configurations supporting up to eight VMAX engines with amaximumof128front-endports.Optimizedhardwarelogicanddataprotectionencodingensuresend-to-end data integrity with automated channel failover for maximum availability and load balancing. Symmetrix VMAX systems support all popular hardware and operating system platforms, storage area networks (SANs), and high-availability cluster environments. IPv6, IPsec, and compression support are availablewithGigEports.IPv6supportisavailablewith10Gb/sEthernet.

protocol usable systeM ports8Gb/sFibreChannelHost/SANPorts 4–128perarray,4–16portsperVMAXengine8Gb/sFibreChannelRemoteReplicationPorts 2–32perarray,2–4portsperVMAXengine8Gb/sFICONHostPorts 4–64perarray,4–8portsperVMAXengine4Gb/sFibreChannelHost/SANPorts 4–128perarray,4–16portsperVMAXengine4Gb/sFibreChannelRemoteReplicationPorts 2–32perarray,2–4portsperVMAXengine4Gb/sFICONHostPorts 4–64perarray,4–8portsperVMAXengine10Gb/s10GigERemoteReplicationPorts 2–32portsperarray,2–4portsperVMAXengine10Gb/sFCoEHostPorts 4–64portsperarray,4–8portsperVMAXengine10Gb/siSCSIHostPorts 4–64portsperarray,4–8portsperVMAXengine1Gb/sGigERemoteReplicationPorts 2–32portsperarray,2–4portsperVMAXengine1Gb/siSCSIPorts 4–64perarray,4–8portsperVMAXengine

Mixedcombinationsoftheaboveporttypesdependupontheconfiguration.RefertotheEMCSupportMatrix at www.EMC.com, or contact your local EMC sales representative for specific configuration support.

EMC SyMMEtrix VMAx StorAgE SyStEM

Page 2: vmax_ss

EMCSymmetrixVMAXsystemsareavailableintwo-to11-bayconfigurationsforuptotwopetabytes of usable storage capacity in a single system. With incremental tiered storage capability for maximum TCO value, Symmetrix VMAX arrays are the highest capacity, fastest, most-scalable, most-capable storage systems available and serve as the foundation of today’s most-demanding intelligent informa-tion infrastructures.

Disk DriVe anD enterprise flasH DriVe connectiVityTheSymmetrixVMAXdriveinfrastructureisarchitectedwith4Gb/sdual-portedFibreChanneldrives,EnterpriseFlashdrives,SASdrives,andSATAdrives,eachsupportedbytwoindependentI/Ochannelswith automatic failover and fault isolation.

3.5” fibre cHannel DriVesCapacity 146 GB 300 GB 300 GB 450 GB 450 GBRotationalSpeed(rpm) 15,000 10,000 15,000 10,000 15,000FormFactor 3.5in 3.5in 3.5in 3.5in 3.5inInterface 4Gb/sFC 4Gb/sFC 4Gb/sFC 4Gb/sFC 4Gb/sFCInternalDataRate(Mb/s) 685–1,142 1,010–1,840 685–1,142 1,010–1,840 1,051–2,225AverageSeekTime(read/write) 3.4/3.9ms 3.8/4.4ms 3.4/3.9ms 3.8/4.4ms 3.4/3.9ms RawCapacity 145.7GB 292.7GB 292.6GB 439.0GB 439.0GB

Formatted CapacityOpenSystems 143.5GB 288.1GB 288.1GB 432.2GB 432.2GBMainframe 139.3GB 279.7GB 279.7GB 419.6GB 419.6GBIBMi 141.7GB 288.2GB 288.2GB 435.1GB 435.1GB

3.5” fibre cHannel DriVes [continued]

Capacity 600 GB 600 GB 1 TB 2 TBRotationalSpeed(rpm) 10,000 15,000 7,200 7,200FormFactor 3.5in 3.5in 3.5in 3.5inInterface 4Gb/sFC 4Gb/sFC 4Gb/sFC 4Gb/sFCInternalDataRate(Mb/s) 1,010–1,840 1,051–2,225 470–1,070 470–1,070AverageSeekTime(read/write) 3.8/4.4ms 3.4/3.9ms 8.2/9.2ms 8.2/9.2msRawCapacity 585.4GB 585.4GB 1000.2GB 2000.3GB

Formatted CapacityOpenSystems 576.3GB 576.3GB 984.8GB 1882.72GBMainframe 559.5GB 559.5GB 956.0GB 1827.67GBIBMi 580.1GB 580.1GB n/a 1912.14GB

2.5” sas DriVesCapacity 300 GB 450 GB 600 GBRotationalSpeed(rpm) 10,000 10,000 10,000FormFactor 2.5in 2.5in 2.5inInterface 4Gb/sFC 4Gb/sFC 4Gb/sFCInternalDataRate(Mb/s) 1219-2029 1219-2029 1219-2029AverageSeekTime(read/write) 3.7/4.2ms 3.7/4.2ms 3.7/4.2msRawCapacity 292.6GB 439.0GB 585.4GB

Formatted Capacity OpenSystems 288.1GB 432.2GB 576.3GBMainframe 279.7GB 419.6GB 559.5GBIBMi 288.2GB 435.1GB 580.1GB

Page 3: vmax_ss

enterprise flasH DriVesCapacity 100 GB* 200 GB 400 GBFormFactor 3.5in 3.5in 3.5inInterface 4Gb/sFC 4Gb/sFC 4Gb/sFCInternalDataRate(Mb/s) 800-1,600 800–1,600 800–1,600RawCapacity 100.0GB 200.0GB 400.0GB

Formatted CapacityOpenSystems 91.7GB 196.9GB 393.8GBMainframe 95.6GB 191.2GB 382.3GBIBMi 97.5GB 197.0GB 389.8GB

* Contact your local EMC representative to obtain ordering and availability details on these drives.

systeM capacities in tb 146 GB Drives 2 TB Drives Min. Max. Min. Max.NumberofDrives 48 2,400 48 2,400MirroredCapacity: OpenSystems 2.87 168.79 37.65 2,067.23 Mainframe 2.79 163.86 36.55 2,006.78RAID-5 3+1Capacity: OpenSystems 4.31 253.19 56.48 2,067.23 Mainframe 4.18 245.80 54.83 2,006.78RAID-5 7+1Capacity: OpenSystems 5.02 295.38 65.90 2,055.93 Mainframe 4.88 286.76 63.97 1,995.82RAID-6 6+2Capacity: OpenSystems 4.31 253.19 56.48 2,067.23 Mainframe 4.18 245.80 54.83 2,006.78RAID-6 14+2Capacity: OpenSystems 5.02 295.38 79.07 2,055.93 Mainframe 4.88 286.76 76.76 1,995.82

Configurations with mixed drive capacities and speeds are allowed depending upon the configuration. 64GBoftotalcapacitywillbereservedforinternalSymmetrixfilesystemuse.Allcapacitiesarebasedon1GB=1,000,000,000bytes.Actualusablecapacitymayvarydependinguponconfiguration.

Data at rest encryptionDataatRestEncryptionisdeliveredthroughanewSymmetrixVMAXmodelwithbuilt-in,hardware-based data encryption. Data is encrypted when written to drives and decrypted when read from the driveswithnoimpactonperformanceorlocalandremotereplication.SymmetrixDataatRestEncryp-tion addresses security and compliance concerns regarding data exposure when drives are removed or arrays are replaced.

pHysical anD cooling specifications Front and Rear Service Height* Width Depth Area Weight Power Cooling (in/cm) (in/cm) (in/cm) (in/cm) (lb/kg) (kVA) (BTU/hr)4-Engine 76.66/194.7 30.2/76.7 41.88/106.4 42.0/106.7 1,830/830.0 4.1 13,700 SystemBay

8-Engine 76.66/194.7 30.2/76.7 41.88/106.4 42.0/106.7 2,774/1258.3 7.8 26,300 SystemBay

StorageBay 76.66/194.7 30.2/76.7 41.88/106.4 42.0/106.7 2,144/972.5 6.1 19,800

All dimensions are cabinet/enclosure size without shipping brackets or securing brackets.Weight, power, and cooling are maximum for a full configuration.Cooling is front to rear for system bay and front to top for storage bays.*Anadditional18in.(45.7cm)isrecommendedforceiling/topclearance.

Page 4: vmax_ss

EMC2, EMC, Symmetrix, Virtual Matrix, Virtual Matrix Architecture, VMAX, and the EMC logo are registered trademarks or trademarks of EMCCorporationintheUnitedStatesandothercountries.Intel,theIntellogo,Xeon,andXeonInsidearetrademarksorregisteredtrademarksofIntelCorporationintheU.S.andothercountries.Allothertrademarksusedhereinarethepropertyoftheirrespectiveowners.©Copyright2009,2011EMCCorporation.Allrightsreserved.PublishedintheUSA.09/11SpecificationSheetH6176.9

EMC CorporationHopkinton, Massachusetts 01748-9103 1-508-435-1000 in north america 1-866-464-7381 www.eMc.com

power specifications—storage bay anD systeM bay North America International 3-phase 3-phase North America International (Delta-4 wire) (Wye-5 wire) Single-phase Single-phaseInputVoltage(VAC) 200–240 200–240 200–240 200–240Frequency(Hz) 50–60 50–60 50–60 50–60CircuitBreaker(Amps), 50 32 30 32 RecommendedACPowerConnections 2perbay 2perbay 4perbay 4perbayPowerConnector* CS8365C S52.30 L6-30P L6-30PUserConnector* SeeNote1 SeeNote1 SeeNote1 SeeNote1

* Specifications given are for the power connectors located inside the Symmetrix VMAX system and storage bays. EMC offers a selection of power cable extensions with different power connectors for con-nectiontothecustomer’spowersource.Refertothe“VMAXSeriesPhysicalPlanningGuide”fordetails.Thepowercableextensiontypedesiredmustbeverifiedatthetimeofquotationandordering.

Note1:Refertothe“VMAXSeriesPhysicalPlanningGuide.”

enVironMental specifications (operating)Temperature(°F/°C) 50–90/10–32Altitude(ft/m),max. 7,500/2,286Humidity(%),Non-condensing 20–80RaisedFloor Recommended