vn series technical data and performance curves vn 3 | vn ... · lower mechanical seal...
TRANSCRIPT
VN Series Technical Data and Performance Curves
VN 3 | VN 5 | VN 9
Outer case Stainless steel DIN-EN 1.4301 (AISI 304)Suction strainer Stainless steel DIN-EN 1.4301 (AISI 304)Motor housing Stainless steel DIN-EN 1.4301 (AISI 304)Covers/flanges motor casing Stainless steel DIN-EN 1.4301 (AISI 304)Pump shaft Stainless steel DIN-EN 1.4301 (AISI 304)Diffuser/s Stainless steel DIN-EN 1.4301 (AISI 304)Impeller/s Stainless steel DIN-EN 1.4301 (AISI 304)Screws and washers Stainless steel DIN-EN 1.4301 (AISI 304)Discharge head Nickel plated pressed brass alloy UNI-EN 12165-98Upper mechanical seal Ceramic/Carbon/NBRLower mechanical seal Ceramic/Carbon/NBR
PART DESCRIPTION MATERIAL
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifications without prior notice.
0
20
10
40
30
60
50
80
70
100
90
130
120
110
0
450
400
350
300
250
200
150
100
50
4 6 8 10 12 14 16 18
m
U.S. gpm
(m3/h)
ft
50 Hz
0 2 3 5 7 9 11 13 15 171
0 10 155 20 25 30 35 40 45 50 55 60 65 70 75 80
up to 1.5 kW
up to 2.2 kW
up to 3 kW
0
20
10
40
30
60
50
80
70
100
90
130
120
110
0
450
400
350
300
250
200
150
100
50
4 6 8 10 12 14 16 18
m
U.S. gpm
(m3/h)
ft
60 Hz
0 2 3 5 7 9 11 13 15 171
0 10 155 20 25 30 35 40 45 50 55 60 65 70 75 80
up to 1.5 kW
up to 2.2 kW
up to 3 kW
Pump ModelNUMBER
OF STAGESMOTOR POWER INPUT
POWER INTERNAL CAPACITOR RATED CURRENTSingle-phase
220-240VThree-phase
380-415VSingle-phase
220-240VThree-phase
380-415VKw HP kW uF VVN 3/4 - 4 0.5 0.75 0.84 20 450 4.1VN 3/5 - 5 0.75 1 0.99 20 450 4.7VN 3/6 - 6 0.75 1 1.15 20 450 5.2VN 3/7 - 7 0.9 1.2 1.34 30 450 6.7VN 3/8 VN 3/8T 8 1.1 1.5 1.5 30 450 7.2 2.7VN 3/9 VN 3/9T 9 1.5 2 1.73 35 450 9.2 3.1VN 3/10 VN 3/10T 10 1.5 2 1.89 35 450 9.8 3.2
Pump model PACKAGINGSingle-phase
220 -240 VThree-phase 380 -415 V
Lt mm
L mm
B mm mm
Weight kgSingle-phase Three-phase
VN 3/4 - 480 720 230 175 16VN 3/5 - 504 720 230 175 18VN 3/6 - 528 720 230 175 18.5VN 3/7 - 552 720 230 175 20VN 3/8 VN 3/8T 576 720 230 175 20.5 19.5VN 3/9 VN 3/9T 650 800 230 195 23.5 21.5VN 3/10 VN 3/10T 674 800 230 195 24 22
� Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
� Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
32mm(1) Rp 32mm(1”¼)
Pump ModelNUMBER
OF STAGESMOTOR POWER INPUT
POWER INTERNAL CAPACITOR RATED CURRENTSingle-phase
220-240VThree-phase
380-415VSingle-phase
220-240VThree-phase
380-415VKw HP kW uF VVN 5/4 - 4 0.75 1 1.07 20 450 5.0 -VN 5/5 - 5 0.9 1.2 1.34 30 450 6.6 -VN 5/6 VN 5/6T 6 1.1 1.5 1.56 30 450 7.4 2.7VN 5/7 VN 5/7T 7 1.5 2 1.86 35 450 9.7 3.2VN 5/8 VN 5/8T 8 1.5 3 2.08 35 450 10.5 3.5VN 5/9 VN 5/9T 9 2.2 3 2.35 45 450 10.7 5.0VN 5/10 VN 5/10T 10 2.2 3 2.56 45 450 11.5 5.2
Pump model PACKAGINGSingle-phase
220 -240 VThree-phase 380 -415 V
Lt mm
L mm
B mm mm
Weight kgSingle-phase Three-phase
VN 5/4 - 480 720 230 175 17.5 -VN 5/5 - 504 720 230 175 19.0 -VN 5/6 VN 5/6T 528 720 230 175 19.5 18.5VN 5/7 VN 5/7T 602 800 230 195 22.5 20.5VN 5/8 VN 5/8T 626 800 230 195 23.0 21.0VN 5/9 VN 5/9T 650 800 230 195 25.0 23.5VN 5/10 VN 5/10T 674 800 230 195 25.5 24.0
� Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
� Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
5
Rp 32mm(1”¼)
Pump ModelNUMBER
OF STAGESMOTOR POWER INPUT
POWER INTERNAL CAPACITOR RATED CURRENTSingle-phase
220-240VThree-phase
380-415VSingle-phase
220-240VThree-phase
380-415VKw HP kW uF VVN 9/3 - 3 1.1 1.5 1.44 30 450 6.9 -VN 9/4 VN 9/4T 4 1.5 2 1.86 35 450 9.7 3.2VN 9/5 VN 9/5T 5 2.2 3 2.30 45 450 10.5 5.0VN 9/6 VN 9/6T 6 2.2 3 2.68 45 450 11.9 5.4
- VN 9/7T 7 3 4 3.16 - - - 5.9- VN 9/8T 8 3 4 3.54 - - - 6.3- VN 9/9T 9 3 4 3.91 - - - 6.8
Pump model PACKAGINGSingle-phase
220 -240 V 50Hz
Three-phase 380 -415 V
50Hz
Lt mm
L mm
B mm mm
Weight kgSingle-phase Three-phase
VN 9/3 - 504 720 230 175 18.5 -VN 9/4 VN 9/4T 584 720 230 175 21.5 19.5VN 9/5 VN 9/5T 614 800 230 195 23.5 22.0VN 9/6 VN 9/6T 644 800 230 195 24.5 22.5
- VN 9/7T 674 800 230 195 - 24.5- VN 9/8T 704 800 230 195 - 25.0- VN /99T 734 800 230 195 - 25.5
� Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
� Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
Rp 32mm(1”¼)
Corporate Headquarter
400 E Spring St. Bluffton, IN 46714 USATel: +1 260-824-2900 Fax: +1 260-824-2909
Franklin eleCtriC india pvt. ltd.
DBS 206, 1st Floor, World Trade Tower, Barakhamba Avenue, Connaught Place, New Delhi 110 001 (INDIA)
Tel: +91 11 4308 4697, 4050 9206 Fax: +91 11 2341 4740 Email: [email protected]
www.franklin-electric.com
Vertical S.r.l.via Asolo, 7
36031 Dueville (Vicenza) - ItalyTel. +39 0444 361114Fax +39 0444 365247
P.IVA e C.F. 00558130241e-mail: [email protected]
www.etechpumps.comSingle member - Company subject to the control
and coordination of Franklin Electric Co., Inc.
VL IN-LINE SERIES
0010
3570
_ed.
02/2
014
1/24
INDEXVL In-Line 5" Close-Coupled Multistage Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3General Product Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Material Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical Data and Performance Curves 50Hz VL 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 VL 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 VL 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Technical Data and Performance Curves 60Hz VL 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 VL 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 VL 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Pump Section and List of Main Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
4/24
APPLICATIONS Pressure boosting Water distribution Water supply from wells or fi rst collecting tanks Rainwater collection Wash down unit Irrigation / Gardening / Sprinklers Fountains and water games Specifi c applications to cape problems of noise Specifi c applications to cape problems of space-saving
FEATURES Full stainless steel compact and solid structure Impellers and diffusers are made of stainless steel in order to achieve durability, superior effi ciency and the highest performances Double mechanical seal separated by an oil chamber for maximum motor protection
*In compliance with FDA - Food, Drug Administration - and the annex to G.U. no. 104 of 20/04/73 for oils in contact with food stuffs
Plug-in type power cable and level control (fl oater) for easy replacement External capacitor easily accessible (single-phase only) Extremely silent pump thanks to the inside motor, cooled by the pumped liquid itself Pump fi tted with fl anged connections to allow for easy installation in narrow spaces or, more simply, in line with the pipeline
SPECIFICATIONS Capacities up to 14 m³/h and heads up to 11 Bar Discharge outlet 1"¼ Rp Suction inlet 1"½ Rp Discharge and suction outlets prepared for quick connection with oval fl anges Maximum working pressure: 15 Bar Maximum immersion depth: 20 m Liquid temperature range: from -5°C to +40°C Asynchronous motor, Class F insulation, IP68 protection Motor range: 0,55kW to 3kW Nominal voltages: Single-phase 220-240 V ±5%, 50 Hz; Three-phase 380-415 V ±5%, 50 Hz Maximum number of starts per hour: 20 1,5 m of power cable type H07RN F is supplied with the standard version Continuous operation either in vertical or horizontal positionAVAILABLE OPTIONS
AVAILABLE ON REQUEST Single-phase models equipped with level control (fl oater) Control and protection panel for single-phase models Various voltages and frequencies Various power cable lenghts Suction outlet 1"¼ Rp Oval counterfl anges to be welded Oval counterfl anges screwed Stainless steel fl anged connectors for the assembling of simple pressurization groups 2-pumps groups complete with collectors, pressure-switches panel, built-in check valves and ball valves
PUMP IDENTIFICATION CODE
Nominal flow rate in m3/h
60 Hz (without is 50 Hz)Three-phase version (without is single-phase)
Pump type
VL 3 1 0 6T/
No. of stages
0011
7032
06
/201
2
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
5/24
MATERIAL IN CONTACT WITH THE LIQUIDMATERIAL
Pos. Parts Descriptions Type AISI DIN / EN10.00 Discharge head Stainless steel 304 1.4301
20.00 Outer case with suction head Stainless steel 304 1.4301
30.00 Motor housing Stainless steel 304 1.4301
30.01 / 30.04 Covers/fl anges motor casing Stainless steel 304 1.4301
30.05 / 30.06 Upper mechanical seal Ceramic / Carbon / NBR
30.06 Lower mechanical seal Silicon Carbide / Carbon / NBR
30.08 Pump shaft Stainless steel 304 1.4301
30.09 Screws and washers Stainless steel 304 1.4301
40.00 / 40.01 / 40.03 Diffuser/s Stainless steel 304 1.4301
50.00 / 50.01 Impeller/s with spacers Stainless steel 304 1.4301
0
20
10
40
30
60
50
80
70
100
90
130
120
110
0
450
400
350
300
250
200
150
100
50
4 6 8 10 12 14 16 18
m
U.S. gpm
(m3/h)
ft
0 2 3 5 7 9 11 13 15 171
0 10 155 20 25 30 35 40 45 50 55 60 65 70 75 80
up to 1.5 kW
up to 2.2 kW
up to 3 kW
41 45 43% VL 3
51 56 50% VL 5
61 61 5662 63 66 63% VL 9
60 Hz
0
20
10
40
30
60
50
80
70
100
90
130
120
110
0
450
400
350
300
250
200
150
100
50
4 6 8 10 12 14 16 18
m
U.S. gpm
(m3/h)
ft
0 2 3 5 7 9 11 13 15 171
0 10 155 20 25 30 35 40 45 50 55 60 65 70 75 80
up to 1.5 kW
up to 2.2 kW
up to 3 kW
40 45 42.5% VL 3
52 56 49% VL 5
62 5563.5 66 63 60% VL 9
50 Hz
0011
2006
06
/200
8
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
6/24
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
8/24
VL 3Technical data 50Hz
Dimensions and weights
Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
Pump modelNUMBER OF
STAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Single-phase220-240V
50Hz
Three-phase380-415V
50HzkW HP kW μF VVL 3/4 - 4 0.55 0.75 0.84 20 450 4.1 -VL 3/5 - 5 0.75 1 0.99 20 450 4.7 -VL 3/6 - 6 0.75 1 1.15 20 450 5.2 -VL 3/7 - 7 0.9 1.2 1.34 30 450 6.7 -VL 3/8 VL 3/8T 8 1.1 1.5 1.50 30 450 7.2 2.7VL 3/9 VL 3/9T 9 1.5 2 1.73 35 450 9.2 3.1
VL 3/10 VL 3/10T 10 1.5 2 1.89 35 450 9.8 3.2
Pump model PACKAGINGSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 3/4 - 464 720 230 175 14.0 -VL 3/5 - 488 720 230 175 16.0 -VL 3/6 - 512 720 230 175 16.5 -VL 3/7 - 536 720 230 175 18.0 -VL 3/8 VL 3/8T 560 720 230 175 18.5 17.5VL 3/9 VL 3/9T 634 800 230 195 21.5 19.5
VL 3/10 VL 3/10T 658 800 230 195 22.0 20.0
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
9/24
VL 3
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 3/4
VL 3/10
VL 3/6
VL 3/5
VL 3/7
VL 3/8
VL 3/9
0011
0063
05
/201
0
Performance curves 50Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
10/24
VL 5Technical data 50Hz
Dimensions and weights
Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
Pump modelNUMBER OF
STAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Single-phase220-240V
50Hz
Three-phase380-415V
50HzkW HP kW μF VVL 5/4 - 4 0.75 1 1.07 20 450 5.0 -VL 5/5 - 5 0.9 1.2 1.34 30 450 6.6 -VL 5/6 VL 5/6T 6 1.1 1.5 1.56 30 450 7.4 2.7VL 5/7 VL 5/7T 7 1.5 2 1.86 35 450 9.7 3.2VL 5/8 VL 5/8T 8 1.5 2 2.08 35 450 10.5 3.5VL 5/9 VL 5/9T 9 2.2 3 2.35 45 450 10.7 5.0
VL 5/10 VL 5/10T 10 2.2 3 2.56 45 450 11.5 5.2
Pump model PACKAGINGSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 5/4 - 464 720 230 175 15.5 -VL 5/5 - 488 720 230 175 17.0 -VL 5/6 VL 5/6T 512 720 230 175 17.5 16.5VL 5/7 VL 5/7T 586 800 230 195 20.5 18.5VL 5/8 VL 5/8T 610 800 230 195 21.0 19.0VL 5/9 VL 5/9T 634 800 230 195 23.0 21.5
VL 5/10 VL 5/10T 658 800 230 195 23.5 22.0
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
11/24
VL 5
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 5/4
VL 5/10
VL 5/6
VL 5/5
VL 5/7
VL 5/8
VL 5/9
0011
0064
05
/201
0
Performance curves 50Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
12/24
VL 9Technical data 50Hz
Dimensions and weights
Single-phase motors: 220-240 V ± 5 % / 50 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 380-415 V ± 5 % / 50 Hz. Thermal protection to be provided into the starter panel by the installer.
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
Pump modelNUMBER OF
STAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Single-phase220-240V
50Hz
Three-phase380-415V
50HzkW HP kW μF VVL 9/3 - 3 1.1 1.5 1.44 30 450 6.9 -VL 9/4 VL 9/4T 4 1.5 2 1.86 35 450 9.7 3.2VL 9/5 VL 9/5T 5 2.2 3 2.30 45 450 10.5 5.0VL 9/6 VL 9/6T 6 2.2 3 2.68 45 450 11.9 5.4
- VL 9/7T 7 3 4 3.16 - - - 5.9- VL 9/8T 8 3 4 3.54 - - - 6.3- VL 9/9T 9 3 4 3.91 - - - 6.8
Pump model PACKAGINGSingle-phase
220-240V50Hz
Three-phase380-415V
50Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 9/3 - 488 720 230 175 16.5 -VL 9/4 VL 9/4T 568 720 230 175 19.5 17.0VL 9/5 VL 9/5T 598 800 230 195 21.5 20.0VL 9/6 VL 9/6T 628 800 230 195 22.0 20.5
- VL 9/7T 658 800 230 195 - 22.5- VL 9/8T 688 800 230 195 - 23.0- VL 9/9T 718 800 230 195 - 23.5
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
13/24
VL 9
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 9/3
VL 9/9
VL 9/5
VL 9/4
VL 9/6
VL 9/7
VL 9/8
0011
0065
05
/201
0
Performance curves 50Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
14/24
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
15/24
VL SeriesPerformance Curvesand Technical Data
VL 3 60Hz
VL 5 60Hz
VL 9 60Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
16/24
VL 3Technical data 60Hz
Dimensions and weights
Single-phase motors: 220-230 V ± 5 % / 60 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 220-230 V or 380-400 V ± 5 % / 60 Hz. Thermal protection to be provided into the starter panel by the installer.
Pump modelNUMBER
OFSTAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Single-phase Three-phase
kW HP kW μF V 220-230V 220-230V 380-400VVL 3/36 - 3 0.75 1 1.05 20 450 5.2 - -VL 3/46 VL 3/4T6 4 0.9 1.2 1.30 20 450 6.2 4.5 2.6VL 3/56 VL 3/5T6 5 1.1 1.5 1.61 25 450 8.0 5.2 3.0VL 3/66 VL 3/6T6 6 1.5 2 1.99 35 450 9.2 6.2 3.6VL 3/76 VL 3/7T6 7 1.5 2 2.26 35 450 10.4 6.8 3.9
Pump model PACKAGINGSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 3/36 - 440 720 230 175 13.5 -VL 3/46 VL 3/4T6 464 720 230 175 14.0 14.5VL 3/56 VL 3/5T6 488 720 230 175 16.0 15.0VL 3/66 VL 3/6T6 562 720 230 175 18.5 16.5VL 3/76 VL 3/7T6 586 800 230 195 19.0 17.0
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
17/24
VL 3
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 3/76
VL 3/36
VL 3/46
VL 3/56
VL 3/66
0011
0063
05
/201
0
Performance curves 60Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
18/24
VL 5Technical data 60Hz
Dimensions and weights
Single-phase motors: 220-230 V ± 5 % / 60 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 220-230 V or 380-400 V ± 5 % / 60 Hz. Thermal protection to be provided into the starter panel by the installer.
Pump modelNUMBER
OFSTAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Single-phase Three-phase
kW HP kW μF V 220-230V 220-230V 380-400VVL 5/26 - 2 0.75 1 1.00 20 450 5.0 - -VL 5/36 VL 5/3T6 3 0.9 1.2 1.35 20 450 6.4 4.7 2.7VL 5/46 VL 5/4T6 4 1.1 1.5 1.78 25 450 8.6 5.5 3.2VL 5/56 VL 5/5T6 5 1.5 2 2.26 35 450 10.4 6.8 3.9
- VL 5/6T6 6 2.2 3 2.78 - - - 9.9 5.7- VL 5/7T6 7 2.2 3 3.16 - - - 10.6 6.1
Pump model PACKAGINGSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 5/26 - 416 720 230 175 13.0 -VL 5/36 VL 5/3T6 440 720 230 175 13.5 -VL 5/46 VL 5/4T6 464 720 230 175 15.5 13.5VL 5/56 VL 5/5T6 538 720 230 175 18.5 14.0
- VL 5/6T6 562 720 230 175 - 16.5- VL 5/7T6 586 800 230 195 - 19.0
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
19/24
VL 5
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 5/66
VL 5/76
VN 5/26
VL 5/36
VL 5/46
VL 5/56
0011
0064
05
/201
0
Performance curves 60Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
20/24
VL 9Technical data 60Hz
Dimensions and weights
Single-phase motors: 220-230 V ± 5 % / 60 Hz. Thermal protection built into the motor up to 1,1 kW. Thermal protection provided into the starter panel from 1,5 kW and above.
Three-phase motors: 220-230 V or 380-400 V ± 5 % / 60 Hz. Thermal protection to be provided into the starter panel by the installer.
Pump modelNUMBER
OFSTAGES
MOTORPOWER
INPUTPOWER
INTERNALCAPACITOR
RATED CURRENTSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Single-phase Three-phase
kW HP kW μF V 220-230V 220-230V 380-400VVL 9/26 VL 9/2T6 2 1.1 1.5 1.59 25 450 7.9 5.0 2.9VL 9/36 VL 9/3T6 3 1.5 2 2.36 35 450 10.8 7.1 4.1
- VL 9/4T6 4 2.2 3 3.17 - - - 10.6 6.1- VL 9/5T6 5 3 4 3.75 - - - 11.8 6.8
Pump model PACKAGINGSingle-phase
220-230V60Hz
Three-phase220-230V or 380-400V
60Hz
Ltmm
Lmm
Bmm
Hmm
Weight kg
Single-phase Three-phaseVL 9/26 VL 9/2T6 458 800 230 175 14.5 13.5VL 9/36 VL 9/3T6 488 720 230 175 17.5 15.5
- VL 9/4T6 568 720 230 175 - 18.5- VL 9/5T6 598 720 230 195 - 20.0
L
B
H
PACKAGING
Rp 1" 1/2
75
75
Rp 1" 1/4
Ø129
Lt
0011
4089
06
/201
2
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
21/24
VL 9
The hydraulic characteristics are guaranteed, according to ISO standard 9906, Annex A, grade 2.
VL 9/26
VL 9/36
VL 9/46
VL 9/56
0011
0065
05
/201
0
Performance curves 60Hz
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
22/24
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
23/24
VL SeriesPump Section and
List of Main Components
VL 3VL 5VL 9
It is our policy to continuously develop and improve our products, therefore, we reserve the right to amend specifi cations without prior notice.
24/24
Section and List of Main ComponentsVL 3/5/9
10.00
10.02
30.0530.0930.0130.0230.0530.00
20.00
30.08
30.0330.05
30.04
40.0130.0940.0040.0250.00
50.01
40.03
30.09
30.06
30.07
30.07
10.03
10.01
30.05
10.04
0011
4088
06
/201
2
Ref.N. Description10 00 Discharge head10 01 Screws for pre-loading assembly (3 pcs)10 02 Power cable assembly10 03 Screws and inserts (6 pcs)10 04 Level control assembly20 00 Outer case with suction head30 00 Motor housing and stator30 01 Upper motor cover30 02 Upper bearing housing30 03 Lower motor cover30 04 Lower bearing cover30 05 Kit O-Rings (20 pcs)30 06 Kit mechanical seals (2 pcs)30 07 Kit ball bearings (2 pcs)30 08 Rotor and pump shaft30 09 Kit screws, nut and washers40 00 Stage housing and diffuser40 01 Spacer40 02 Floating neck ring assembly40 03 Initial stage housing50 00 Impeller50 01 Impeller spacers (2 pcs)
1) For VL 9, Diffusers = Impellers + 1. Ex. VL 9/4 = 4 impellers and 5 diffusers.
Vertical S.r.l.via Asolo, 7
36031 Dueville (Vicenza) - ItalyTel. +39 0444 361114Fax +39 0444 365247
P.IVA e C.F. 00558130241e-mail: [email protected]
www.etechpumps.comSingle member - Company subject to the control
and coordination of Franklin Electric Co., Inc.
VL IN-LINE SERIES