Cutler-HammerJanuary 2001Vol. 2, Ref. No. [0545J
Distribution & Control TransformersDistribution TransformersGeneral Purpose
Table 44-5. Single-Phase Selection Information — Type EP, 60 HzkVA Full Cap. Taps
FCAN FCBNType °C
Temp.Rise
Dimensions (Inches)H W D
Wt.Lbs.
Dimensions (mm)H W D
Wt.kg
Frame WiringDiagramNumber
CatalogNumber
PriceU.S.S
190/200/208/220 x 380/400/416/440 Volts to 110/220 Volts 50/60 Hz — Export Model IP 24 Rated
240 x 480 Volts to 120/240 Volts Stainless Steel '
480 Volts to 120/240 Volts
480 Volts to 120/240 Volts Stainless Steel, Copper Windings
600 Volts to 120/240 Volts
® NEMA 3R, 316 stainless steel enclosure.Note: Contact your local Cutler-Hammer sales office for CE Mark transformer requirements.
11.52
357.5
1015
————————
———_————
EPEPEPEPEPEPEPEP
1 1 51 1 51 1 51 1 51151 1 51151 1 5
10-3/410-3/411-1/812-7/812-7/815-7/8
15-7/817-1/8
6-1/86-1/87-3/4
10-3/810-3/813-3/8
13-3/816-3/8
6-5/86-5/88
9-7/89-7/810-5/810-5/814-1/8
424670
1 1 3140193
216375
273273281
326326402
402433
155155197
264264340
340415
166166203
251251267
267359
192133516387
98170
6767176
177178179
180182
538A538A538A538A538A538A538A538A
S40N14S01CES40N14S16CES40N14S02CE
S40N14S03CES40N14S05CES40N14S07CES40N14S10CES40N14S15CE
950.1,180.1,400.1,800.2,290.3,170.3,810.4,900.
357.5
101525
=
—
E—
EPEPEPEPEPEP
1 1 51 1 51 1 5
1 1 51151 1 5
14-1/81616
191921-5/16
7-11 /1610-3/810-3/813-3/813-3/816-3/8
89-7/89-7/8
10-1/210-1/214-1/8
651 1 3123
179216375
359406406
482482566
195263263
339339416
203251251
266266359
295155
8798170
176177178
179180182
3A3A3A
3A3A3A
S20N11S03SSS20N11S05SSS20N11S07SSS20N11S10SSS20N11S15SSS20N11S25SS
805.1,240.1,680.
2,045.2,520.3,690.
11.5233557.57.5
101015
152525
—
2-2.5%
2-2.5%
2-2.5%
2-2.5%
2-2.5%
2-2.5%
2-5%2-5%2-5%
2-5%2-2.5%2-5%
2-2.5%2-5%2-2.5%2-5%2-2.5%2-5%2-2.5%2-5%4-2.5%
EPEPEPEPEPEPEPEPEPEPEPEPEPEPEP
1 1 51151 1 5
1 1 51 1 51 1 51 1 51 1 5115
1 1 51 1 51 1 5
1 1 51 1 51 1 5
8-3/810-3/410-3/4
14-1/814-1/816
161616
191919
1922-3/817-7/16
66-3/166-3/167-3/47-3/410-3/810-3/810-3/810-3/813-3/813-3/813-3/813-3/816-3/816-3/8
5-3/46-1/86-1/8
889-7/8
9-7/89-7/89-7/8
10-1/210-1/210-1/210-1/214-1/817-1/4
314040
65651 1 3
1 1 3123123
193193216
216375384
213273273
359359406
406406406
482482482
482568443
152157157
197197263
263263263
339339339
339416416
146156156
203203251
251251251
266266266
266359438
141818
292951
515555
878798
98170174
59A6768
176176177
177178178
179179180
180182132
2D2D2D
2D16A2D
16A2D16A
2D16A2D
16A2D83A
S48G11S01NS48G11S16NS48G11S02NS48G11S03NS48D11S03NS48G11S05NS48D11S05NS48G11S07NS48D11S07NS48G11S10NS48D11S10NS48G11S15NS48D11S15MS48G11S25NS48M11S25N
347.426.510.
620.630.955.
970.1,300.1,320.1,575.1,615.1,940.1,980.2,895.3,010.
101525
2-2.5%2-2.5%2-2.5%
2-2.5%2-2.5%4-2.5%
EPEPEP
1 1 51151 1 5
191917-7/16
13-3/813-3/816-3/8
10-1/210-1/217-1/4
208235414
482482443
339339416
266266438
94106188
179180132
16A16A83A
S48D11S10SSCUS48D11S15SSCUS48M11S25SSCU-
2,645.3,255.4,960.
.5
.7511.52357.510152525
—
—
—
2-2.5%
2-5%2-5%2-5%2-5%2-5%2-5%2-5%2-5%2-5%
4-2.5%4-2.5%4-2.5%
EPEPEP
EPEPEP
EPEPEP
EPEPEP
1 1 51 1 51 1 5
1 1 5115
1 1 5
1 1 51 1 51 1 5
1 1 51 1 5115
6-1/28-3/88-3/8
10-3/410-3/414-1/8161619
1922-3/817-7/16
4-7/866
6-3/166-3/167-3/4
10-3/810-3/813-3/813-3/816-3/813-5/8
4-5/85-3/45-3/4
6-1/86-1/88
9-7/89-7/810-1/210-1/214-1/817-1/4
132131
404065
113123193
216375384
165213213
273273359
406406482
482568443
124152152
157157197
263263339
339416416
1 1 7146146
156156203
251251266
266359438
61014
181829
515587
98170174
5758A59A
6768176
177178179
180182132
212121
212121
212121
527A527A83B
S60G11S51NS60G11S76NS60G11S01N
S60G11S16NS60G11S02NS60G11S03NS60G11S05NS60G11S07NS60G11S10N
S60J11S15NS60J11S25NS60M11S25N
278.368.430.
505.635.770.
1,070.1,450.1,765.2,130.3,410.3,475.
For other ratings or styles not shown, or forspecial enclosure types (including stainlesssteel) refer to Cutler-Hammer. Discount Symbol. DT-1
CAT.201.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T.N
Distribution & Control TransformersDistribution TransformersGeneral Purpose
Cutler-HammerJanuary 2001
Vol. 2, Ref. No. [05421
Single-Phase, Type EP, 60 Hz•1
Type EP 3-25 kVA
Product DescriptionType EP• Sand and Resin Encapsulated design• Suitable for indoor or outdoor
applications• Totally enclosed, non-ventilated
enclosures• Enclosures are NEMA 3R rated• Mountable in any position indoors
and upright only outdoors• 185°C Insulation System, 115°C rise
standard• Available in ratings through 37.5 kVA
and 4160 volts primary
Application DescriptionThe basic purpose of a transformeris voltage transformation as near aspractically possible to the load foreconomy and distribution of power.Typical loads for dry type distributiontransformers include lighting, heating,air conditioners, fans and machinetools. Such loads are found in com-mercial, institutional, industrial andresidential structures.
Features, Benefitsand Functions• UL Listed• 60 Hz operation• Short-term overload capability as
required by ANSI.• Meet NEMA ST-20 sound levels
Standards and CertificationsIndustry StandardsAll Cutler-Hammer dry type distributionand control transformers are built andtested in accordance with applicableNEMA, ANSI, and IEEE Standards.All 600 volt class transformers areUL listed unless otherwise noted.
Seismic QualifiedCutler-Hammer dry type distributiontransformers are seismically qualified,and exceed requirements of theUniform Building Code (UBC) andCalifornia Code Title 24.
Product SpecificationsFrequencyCutler-Hammer standard dry typedistribution transformers are designedfor 60 Hertz operation. Transformersrequired for other frequencies are avail-able and must be specifically designed.
Overload CapabilityShort-term overload is designed intotransformers as required by ANSI. Drytype distribution transformers willdeliver 200% nameplate load for one-half hour; 150% load for one-hour; and125% load for four-hours withoutbeing damaged provided that a con-stant 50% load precedes and followsthe overload. See ANSI C57.96-01.250for additional limitations.
Continuous overload capacity is notdeliberately designed into a trans-former because the design objective isto be within the allowed winding tem-perature rise with nameplate loading.
Insulation System and Temperature RiseIndustry standards classify insulationsystems and rise as shown below:
Table 44-1. Insulation System ClassificationAmbient
40°C40°C40°C40°C
+WindingRise
55°C80°C115-0150°C
+HotSpot
10°C30°C30°C30°C
=
Temp.Class
105°C150°C185°C220°C
The design life of transformers havingdifferent insulation systems is thesame — the lower temperature systemsare designed for the same life as thehigher temperature systems.
EnclosuresCutler-Hammer Type EP encapsulatedtransformers utilize a NEMA 3R ratedenclosure as standard.
Sound LevelsAll Cutler-Hammer 600 volt classgeneral purpose dry type distributiontransformers are designed to meetNEMA ST-20 levels listed here. Lowersound levels are available and must bespecially designed.
Table 44-2. Sound LevelskVA
0-910-505 1 - 1 5 0151-300301 - 500501-700701 -10001001-1500
NEMA Average <!>Sound Level in dB
4045505560626465
© Applies to general purpose transformers only.
Winding TerminationsPrimary and secondary windings areterminated in the wiring compartment.Encapsulated units have copper leadsor stabs brought out for connections.Lugs are not supplied with thesetransformers. Cutler-Hammer recom-mends external cables be rated 90°C(sized at 75°C ampacity) for encapsu-lated designs.
Series-Multiple WindingsSeries-multiple windings consist of2 similar coils in each winding whichcan be connected in series or parallel(multiple). Transformers with series-multiple windings are designated withan "X" or "/" between the voltageratings, such as voltages of "120/240"or "240 X 480." If the series-multiplewinding is designated by an "X," thewinding can be connected only for aseries or parallel. With the "/" designa-tion, a mid-point also becomes availablein addition to the series or parallel con-nection. As an example, a 120 X 240winding can be connected for either120 (parallel) or 240 (series), but a120/240 winding can be connected for120 (parallel), or 240 (series), or 240with a 120 mid-point.
The following pages provide listings for moststandard transformer ratings and styles.
For other ratings or styles not shown, or forspecial enclosure types (including stainlesssteel) refer to Cutler-Hammer.
F.T-N For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.201.01.T.E