This brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment change from time to time, the features shown and described in this document must be confirmed by our departments. This brochure may not be reproduced in whole or in part without the written consent of Fresenius Kabi. The signs/names marked with «®» are registered trademarks of the Fresenius Group in selected countries. 7393061 (02.17/AC) Fresenius Kabi Deutschland GmbH Else-Kröner-Straße 1 61352 Bad Homburg v.d.H. Germany Phone: +49 (0) 61 72 / 686-0 [email protected] www.fresenius-kabi.com Volumat Lines Infusion – Transfusion – Oncology – Paediatric – Parenteral Nutrition

Upload: others

Post on 23-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

This brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions.As standards and equipment change from time to time, the features shown and described in this document must be confirmed by our departments.This brochure may not be reproduced in whole or in part without the written consent of Fresenius Kabi.The signs/names marked with «®» are registered trademarks of the Fresenius Group in selected countries. 73

930

61 (

02

.17/A

C)

Fresenius Kabi Deutschland GmbHElse-Kröner-Straße 161352 Bad Homburg v.d.H.GermanyPhone: +49 (0) 61 72 / [email protected]

Volumat LinesInfusion – Transfusion – Oncology – Paediatric – Parenteral Nutrition

Page 2: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

2 Agilia Volumat Lines

FRESENIUS KABI caring for life

To the Health Care Professional,

Fresenius Kabi applies more than 40 years of experience in developing high

quality infusion systems to support clinicians in reducing IV medication

risks at the patient bedside.

The Volumat Lines are specifically designed for the Agilia volumetric

infusion pumps.

The Agilia volumetric pumps and sets integrate state-of-the-art pumping

mechanisms, to aid in accurate delivery of fluid in the clinical area.

Like all Agilia devices, the Volumat Agilia pumps and sets are very easy and

intuitive to use.

87Agilia Volumat Lines

Notes to remember

Page 3: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

Drip Chamber:Visually control the flow

gDedicated pump set

Upstream Needle-free Access:For Secondary Infusion

Calibrated Silicone Pumping Segment:1/ Color coded for a simple set positioning

in the pump

2/ Includes the blue SafeClamp to provide security against free-flow when set is removed from the pump

3/ Wide range of flow rates4/Precise and stable flow rates

Downstream Needle-free Access:1/ Intermittent injections of drugs not

controlled by the pump2/ Reduce risk of needle stick injuries

Flow-Stop Cap:Automatic prime stop from hydrophobic filter

Volumat Lines available features

3

*DEHPasplasticizerisnotused

DEHP

FREE*

AgiliaVolumatLines

Page 4: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

5Agilia Volumat Lines

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

y S

ets

Sp

ecia

l S

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

ndard

&

Pri

mary

Set

s

4

Volumat Lines

Standard&PrimarySets 16• Standard sets are designed for infusion of drugs or solution • Primary sets are equipped with upstream needle-free access

enabling the connection of secondary sets for Secondary Infusion

OncologySets 24• Equipped with upper needle-free or side lines • Certain oncology sets have special filter or materials

TransfusionSets 48• Equipped with 200 µm filter allowing blood products to be administered • Note: Blood products should only be administered with transfusion sets

Paediatr icSets 54• Equipped either with low diameter tube to limit the priming volume,

or with burette to deliver a defined volume• Note: Standard sets may be suitable for paediatric purposes in many situations

Parenteral Nutrit ionSets 58• Equipped with 1.2 µm filter enabling filtration of solutions containing lipid solutions• Note: When filtration of parenteral nutrition is not required,

other standard infusion sets may also be suitable

Special Sets 62• Use special material or have a special configuration

to allow infusion of certain drugs

SecondarySets 66• Short lines, designed to be attached to primary sets

Addit ional Information 77

*DEHPasplasticizerisnotused

Sec

on

dary

S

ets

On

colo

gy

S

ets

Addit

ion

al

Info

rmati

on

Spec

ial

Set

sP

are

nte

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

an

sfu

sion

S

ets

Sta

ndard

&

Pri

mary

Set

s

DEHP

FREE*

AgiliaVolumatLines

Page 5: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

DESIGNATION VL ST00 VL ST10 VL ST01 VL ST02 VL STO2 ND VL ST22 VL ST42 VL ST44 VL ON10 VL ON11 VL ON12 VL ON15 VL ON20 VL ON22 VL ON22 FX VL ON30 VL ON40 VL ON401

ARTICLE REFERENCE M46441000S M46441300S M46441600S M46441900S M46441980 M46442500S M46442600S M46443200 M46445500S M46443900 M46444800 M46446600 M46445700S M46444200S M46444251 M46445900S M46445100S M46444001

APPLICATION Infusion Infusion Infusion Infusion Infusion Infusion Infusion Infusion

SPIKE Vented / Non-vented/

freeflex®

freeflex®

DRIP CHAMBER nInline

15µmfilter 15µmfilter 15µmfilter 15µmfilter noliquidfilter 15µmfilter 15µmfilter 15µmfilter n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

ROBERTS CLAMP pUpstream / qDownstream

q p p pq pp p p ppp ppp p pq pppp ppp pq

ONE-WAY CHECK VALVE R RNEEDLE-FREE ACCESS pUpstream / qDownstream

q q pq pq pq p p pp ppq ppppq

ROLLER CLAMP R R R R R R R R R R R R R R R R R(3) RANTI-BACTERIAL / AIR ELIMINATING FILTER

3-WAY-STOPCOCK R R R R

INJECTION SITE R

ROTATING MALE LUER LOCK R R R R R R R R R R R R R

FLOW-STOP CAP R R R R R R R R R R R R R R R R

PRIMING VOLUME ~25ml ~25ml ~25ml ~25ml ~25ml ~25ml ~25ml ~26ml ~28ml ~25ml ~25ml ~28ml ~30ml ~25ml ~26ml ~33ml ~34ml ~26ml

LENGTH DOWNSTREAM ~170cm ~170cm ~170cm ~170cm ~170cm ~170cm ~170cm ~170cm ~200cm ~170cm ~170cm ~200cm ~200cm ~170cm ~145cm ~200cm ~200cm ~140cm

APPROXIMATE SET LENGTH ~285cm ~285cm ~285cm ~285cm ~285cm ~285cm ~270cm ~280cm ~310cm ~270cm ~270cm ~310cm ~310cm ~270cm ~270cm ~310cm ~310cm ~270cm

MAIN MATERIALS PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PUR,PP,SILICONE

PVC,SILICONE

PVC,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PVC,SILICONE

PVC,SILICONE

PUR,PP,SILICONE

PAGE 16 PAGE 17 PAGE 18 PAGE 19 PAGE 20 PAGE 21 PAGE 22 PAGE 23 PAGE 24 PAGE 25 PAGE 26 PAGE 27 PAGE 28 PAGE 29 PAGE 30 PAGE 31 PAGE 32 PAGE 33

6 7

STANDARD AND PRIMARY SETS ONCOLOGY SETS

AgiliaVolumatLinesAgiliaVolumatLines

Page 6: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

8 9

DESIGNATION VL ON42 VL ON42 FX VL ON42 SC VL ON45 VL ON70 VL ON72 VL ON90 VL ON91 VL ON22 OP VL ON22 OP NF VL ON42 OP VL ON42 OP NF VL ON42 OP SC

ARTICLE REFERENCE M46444000S M46444051 M46444061 M46446700 M46444600S M46444100S M46444900S M46444901 M46446000S M46444230S M46445801 M46444080S M46444071

SPIKE Vented / Non-vented/

freeflex®

freeflex®

DRIP CHAMBER nInline

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

15µmfilter 15µmfilter 15µmfilter 15µmfilter n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

n 15µmfilter

ROBERTS CLAMP pUpstream / qDownstream

p pq p pppppp p q p pqq p pqq p

ONE-WAY CHECK VALVE

NEEDLE-FREE ACCESS pUpstream / qDownstream

pppp ppppq pppp q q pp ppq pppp ppppq pppp

ROLLER CLAMP R R R R R R R R R R R R RANTI-BACTERIAL / AIR ELIMINATING FILTER

R0.2µmfilter

R0.2µmfilter

3-WAY-STOPCOCK R R

ROTATING MALE LUER LOCK R R R R R R R R R R

FLOW-STOP CAP R R R R R R R R R R R R R

PRIMING VOLUME ~26ml ~26ml ~26ml ~34ml ~25ml ~25ml ~25ml ~24ml ~26ml ~24ml ~26ml ~25ml ~26ml

LENGTH DOWNSTREAM ~140cm ~145cm ~150cm ~170cm ~170cm ~180cm ~160cm ~150cm ~170cm ~150cm ~150cm ~150cm ~150cm

APPROXIMATE SET LENGTH ~270cm ~270cm ~270cm ~280cm ~285cm ~270cm ~285cm ~255cm ~300cm ~265cm ~270cm ~275cm ~270cm

MAIN MATERIALS PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PVC,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PAGE 34 PAGE 35 PAGE 36 PAGE 37 PAGE 38 PAGE 39 PAGE 40 PAGE 41 PAGE 42 PAGE 43 PAGE 44 PAGE 45 PAGE 46

0.2 µm FILTER LIGHT PROTECTED SETS

ONCOLOGY SETS

AgiliaVolumatLinesAgiliaVolumatLines

Page 7: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

SPECIAL SETS

SPECIAL APPLICATION

PARENTERAL NUTRITION SETS

1.2 µm FILTER

VL PN00 VL PN02 VL PN20 VL PN00 FX VL SP22 VL SP62 VL SP90 VL SP92

M46444300S M46444400S M46443700S M46442300S M46443100S M46443400S M46443500S M46443600S

Infusion Infusion Infusion InfusionInfusion and Transfusion

Infusion Infusion Infusion

freeflex®

15µmfilter 15µmfilter n 15µmfilter

15µmfilter n 200µmfilter

15µmfilter 15µmfilter 15µmfilter

p pp

q q q q

R R R R R R R R

R1.2µmfilter

R1.2µmfilter

R1.2µmfilter

R R R R R R

R R R R R R R R

~26ml ~25ml ~26ml ~26ml ~30ml ~25ml ~25ml ~25ml

~170cm ~180cm ~170cm ~170cm ~170cm ~170cm ~170cm ~180cm

~285cm ~290cm ~280cm ~280cm ~290cm ~285cm ~270cm ~270cm

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PUR,PP,SILICONE

PAGE 58 PAGE 59 PAGE 60 PAGE 61 PAGE 62 PAGE 63 PAGE 64 PAGE 65

FREEFLEX® SPIKE LINE

200 µm FILTER

PRIMARY LINE

LIGHT PROTECTED TUBING

10 11

DESIGNATION VL TR00 VL TR12 VL TR21 VL TR22 VL TR42 VL TR43 VL PA02 VL PA92 VL PA93 VL PA94

ARTICLE REFERENCE M46442800S M46442700S M46446200S M46443000S M46442900S M46444500S M46442200S M46445200S M46443800S M46445300S

APPLICATION Transfusion TransfusionInfusion and Transfusion

Infusion and Transfusion

Infusion and Transfusion

Infusion and Transfusion

Infusion Infusion Infusion Infusion

---------------

---------------

---------------

SPIKE Vented / Non-vented/

freeflex®

DRIP CHAMBER nInline

200µmfilter 200µmfilter n 200µmfilter

n 200µmfilter

200µmfilter 200µmfilter 15µmfiltern

150mlburette15µmfilter

n 150mlburette

15µmfilter

n 150mlburette

15µmfilter

ROBERTS CLAMP pUpstream / qDownstream

p p p p p

ONE-WAY CHECK VALVE RNEEDLE-FREE ACCESS pUpstream / qDownstream

q p pq pq pq q pq pq pq

ROLLER CLAMP R R R R R R R R R(2) R(2)

ANTI-BACTERIAL / AIR ELIMINATING FILTER

3-WAY-STOPCOCK

INJECTION SITE

ROTATING MALE LUER LOCK R R R R R R R R R R

FLOW-STOP CAP R R R R R R R R R R

PRIMING VOLUME ~25ml ~25ml ~25ml ~26ml ~25ml ~25ml ~16ml ~25ml ~25ml ~25ml

LENGTH DOWNSTREAM ~170cm ~170cm ~170cm ~170cm ~170cm ~170cm ~110cm ~170cm ~170cm ~170cm

APPROXIMATE SET LENGTH ~285cm ~270cm ~290cm ~285cm ~270cm ~270cm ~180cm ~300cm ~300cm ~300cm

MAIN MATERIALS PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PVC,SILICONE

PAGE 48 PAGE 49 PAGE 50 PAGE 51 PAGE 52 PAGE 53 PAGE 54 PAGE 55 PAGE 56 PAGE 57

200 µm FILTER MICROBORE

PAEDIATRIC SETSTRANSFUSION SETS

BURETTE SETS

AgiliaVolumatLinesAgiliaVolumatLines

Page 8: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

1312

SECONDARY SETS

DESIGNATION SL SL Filter SL FX Filter SL 20 FX ND SL 00 DC SL 00 FX SL 00 OP SL IP SL OP IP SL Filter IP

ARTICLE REFERENCE M77460020 M77460025 M77460026 M77460033 M77460037 M77460062 M77460065 M77460069 M77460068 M77460070

APPLICATION Infusion Infusion Infusion Infusion Infusion Infusion Infusion Infusion Infusion Infusion

SPIKE Vented / Non-vented/

freeflex®

freeflex®

freeflex®

freeflex®

DRIP CHAMBER nInline

noliquidfilter 15µmfilter

ROBERTS CLAMP pUpstream / qDownstream

p p p p p p p p

ONE-WAY CHECK VALVE R R R R RNEEDLE-FREE ACCESS pUpstream / qDownstream

p p p

ROLLER CLAMP R RANTI-BACTERIAL / AIR ELIMINATING FILTER

R0.2µmfilter

R0.2µmfilter

R0.2µmfilter

3-WAY-STOPCOCK

INJECTION SITE

ROTATING MALE LUER LOCK R R R R R R R

FLOW-STOP CAP R R R R R R R R R R

PRIMING VOLUME ~2ml ~5ml ~7ml ~10ml ~12ml ~2.5ml ~2.5ml ~2.6ml ~2.6ml ~5.3ml

LENGTH DOWNSTREAM

APPROXIMATE SET LENGTH ~38cm ~48cm ~78cm ~65cm ~85cm ~45cm ~45cm ~43cm ~43cm ~43cm

MAIN MATERIALS PUR PUR PUR PUR PVC PUR PUR PUR PUR PUR

PAGE 66 PAGE 67 PAGE 68 PAGE 69 PAGE 70 PAGE 71 PAGE 72 PAGE 73 PAGE 74 PAGE 75

AgiliaVolumatLinesAgiliaVolumatLines

Page 9: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

15Agilia Volumat Lines14 AgiliaVolumatLines

Volumat Lines / Sets

Sets for infusion

Sets for trans -fusion

Dripchamberfilter[µm]

Specialcharacteristics

Needlefreeaccess

Sidelines

Drops/ml

Page

StandardandPrimarySets

VLST00 l 15 16

VLST10 l 15 17

VLST01 l 15 1needleinjectionsite 18

VLST02 l 15 1 19

VLST02ND l noliquidfilter 1 20

VLST22 l 15 2 21

VLST42 l 15 1one-waycheckvalve 2 22

VLST44 l 15 1one-waycheckvalve 2 23

OncologySet

VLON10 l 15 3-Way-Stopcock 1 24

VLON11 l 15 1 25

VLON12 l 15 1 26

VLON15 l 15 2spikes 1 27

VLON20 l 3-Way-Stopcock 2 28

VLON22 l 15 2 29

VLON22FX l 15 freeflex® connection 3 30

VLON30 l 15 3-Way-Stopcock 3 31

VLON40 l 15 3-Way-Stopcock,2spikes 3 32

VLON401 l 15 5 33

VLON42 l 15 4 34

VLON42FX l 15 freeflex® connection 5 35

VLON42SC l 15 3-Way-Stopcock 4 36

VLON45 l 15 2spikes 4 37

VLON70 l 15 0.2µmaireliminatingfilter 38

VLON72 l 15 0.2µmaireliminatingfilter 1 39

VLON90 l 15 lightprotection 40

VLON91 l 15 lightprotection 1 41

VLON22OP l 15 lightprotection 2 42

VLON22OPNF l 15 lightprotection 3 43

VLON42OP l 15 lightprotection 4 44

VLON42OPNF l 15 lightprotection 5 45

VLON42OPSC l 153-Way-Stopcock,lightprotection

4 46

TransfusionSets

VLTR00 l 200 48

VLTR12 l 200 1 49

VLTR21 l l 200 1 50

VLTR22 l l 200 2 51

VLTR42 l l 200 1one-waycheckvalve 2 52

VLTR43 l l 200 2 53

*DEHPasplasticizerisnotused

Sec

on

dary

S

ets

On

colo

gy

S

ets

Addit

ion

al

Info

rmati

on

Spec

ial

Set

sP

are

nte

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

an

sfu

sion

S

ets

Sta

ndard

&

Pri

mary

Set

s

PaediatricSets

VLPA02 l 15 microboretube 1 60 54

VLPA92 l 15 buretteset 2 20 55

VLPA93 l 15 buretteset 2 20 56

VLPA94 l 15 buretteset 2 60 57

ParenteralNutritionalSets

VLPN00 l 15 1.2µmaireliminatingfilter 58

VLPN02 l 15 1.2µmaireliminatingfilter 1 59

VLPN20 l 15upstreamLuerLockconnection

60

VLPN00FX l 15freeflex®connection,1.2µmaireliminatingfilter

61

SpecialSets

VLSP22 l l 200 2spikes 1 62

VLSP62 l 15 1 63

VLSP90 l 15 lightprotectedtubing 64

VLSP92 l 15 lightprotectedtubing 1 65

SecondarySets

SL l 66

SLFilter l 0.2µmaireliminatingfilter 67

SLFXFilter lfreeflex®connection,0.2µmaireliminatingfilter

68

SL20FXND l freeflex®connection,nodripchamberfilter

69

SL00DC l 15 secondaryhanger 70

SL00FX l freeflex® connection 71

SL00OP l 72

SLIP l injectionport 1 73

SLOPIP l injectionport 1 74

SLFILTERIP l0.2µmaireliminatingfilter,injectionport

1 75

Sets for infusion

Sets for trans -fusion

Dripchamberfilter[µm]

Specialcharacteristics

Needlefreeaccess

Sidelines

Drops/ml

Page

DEHP

FREE*

Page 10: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

16 17Agilia Volumat LinesAgilia Volumat Lines

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

StandardandPrimarySets StandardandPrimarySets

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

ndard

&

Pri

mary

Set

s

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Antifree-flowsafetyclamp

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Advantages

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Protectivecap

Protectivecap Protectivecap

Flow-StopCap

Ventedspikewithantibacterialfilter

Transparentdripchamber Transparentdripchamber

15µmfilter 15µmfilter

Rollerclamp Rollerclamp

Greenconnector Greenconnector

Calibratedsiliconepumpingsegment

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

BlueSafeClip:antifree-flowsafetyclamp

length~170cm

MaleLuerLock

VL ST00ref.M46441000S

VL ST1Oref.M46441300S

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

length~170cm

Page 11: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

18 19Agilia Volumat LinesAgilia Volumat Lines

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

StandardandPrimarySets StandardandPrimarySets

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

ndard

&

Pri

mary

Set

s

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Patientproximalneedleaccessforemergencyapplication

• Antifree-flowsafetyclamp

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles(mainline)

–havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Advantages

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Injectionsitein“Y”(forneedle),Latex-free

Needle-freeaccess

VL STO1ref.M46441600S

VL ST02ref.M46441900S

Protectivecap

Protectivecap

Ventedspikewithantibacterialfilter

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

Protectivecap

Flow-StopCap

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

length~170cmlength~170cm

Page 12: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

20 21Agilia Volumat LinesAgilia Volumat Lines

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

StandardandPrimarySets StandardandPrimarySets

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

ndard

&

Pri

mary

Set

s

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Noliquidfilterinthedripchamber

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles(mainline)

–havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Advantages

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL STO2 NDref.M46441980

VL ST22ref.M46442500S

Robertsclamp

Needle-freeaccess

RotatingmaleLuerLock

Protectivecap

Flow-StopCap

Transparentdripchamber

15µmfilter

Rollerclamp

Robertsclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Needle-freeaccess

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

Protectivecap

Ventedspikewithantibacterialfilter

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Flow-StopCap

length~170cm length~170cm

Page 13: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

22 23Agilia Volumat LinesAgilia Volumat Lines

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

StandardandPrimarySets StandardandPrimarySets

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

ndard

&

Pri

mary

Set

s

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Approximate set length: 280cm

Approximate priming volume: 26ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• One-waycheckvalve

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles(mainline)

–havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

Advantages

•One-waycheckvalve

•Patientproximalaccessforemergencyapplication

•Antifree-flowsafetyclamp

•Flow-StopCap

•DEHPasplasticizerisnotused

•Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

VL ST42ref.M46442600S

VL ST44ref.M46443200

One-waycheckvalve

Robertsclamp

Needle-freeaccess

Needle-freeaccess

Protectivecap

Flow-StopCap

Transparentdripchamber

15µmfilter

Rollerclamp

One-waycheckvalve

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Ventedspikewithantibacterialfilter

Needle-freeaccess

Robertsclamp

Protectivecap

Ventedspikewithantibacterialfilter

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

length~170cm length~170cm

RotatingmaleLuerLock

Page 14: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

24 25

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 310cm

Approximate priming volume: 28ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock(sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Spikeablebagsnorbottlesinsideline

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Flow-StopCap

ProtectiveCap

Ventedspikewithantibacterialfilter

Yconnector

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

VL ON10ref.M46445500S

length~200cm

2xRobertsclamp

FemaleLuerLockCap

RotatingmaleLuerLock

3-Way-Stopcock

TransparentIn-linedripchamber

15µmfilter

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON11ref.M46443900

Flow-StopCap

ProtectiveCap

Ventedspikewithantibacterialfilter

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

length~170cm

Robertsclamp

15µmfilter

Needle-freeaccess

TransparentIn-linedripchamber

Rollerclamp

Page 15: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

26 27

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON12ref.M46444800

Flow-StopCap

ProtectiveCap

Ventedspikewithantibacterialfilter

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

length~170cm

Robertsclamp

15µmfilter

Needle-freeaccess

TransparentIn-linedripchamber

Rollerclamp

2xYconnector

FemaleLuerLockCap

RotatingmaleLuerLock

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock (sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• Secondaryinfusion

Not to be used for / in

• Bloodcells

• InfusionofdrugstobeknwontobeincompatiblewithPVC(e.g.trinitrine,isosorbidedinitrate,sodiumnitroprussiate...)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON15ref.M46446600

Approximate set length: 310cm

Approximate priming volume: 28ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

2xProtectiveCap

2xVentedspikewithantibacterialfilter

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~200cm

Robertsclamp

Rollerclamp

15µmfilter

TransparentIn-linedripchamber

Page 16: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

28 29

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

2xYconnector

Ventedspikewithantibacterialfilter

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock(sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Spikeablebagsnorbottlesinsideline

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON20ref.M46445700S

Approximate set length: 310cm

Approximate priming volume: 30ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~200cm

3xRobertsclamp

2xfemaleLuerLockCap

2xRotatingmaleLuerLock

3-Way-Stopcock

15µmfilter

TransparentIn-linedripchamber

Advantages

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON22ref.M46444200

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Ventedspikewithantibacterialfilter

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

length~170cm

Robertsclamp

2xNeedle-freeaccess

Rollerclamp

15µmfilter

TransparentIn-linedripchamber

Page 17: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

30 31

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Advantages

•Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

•Patientproximalaccessforemergencyapplication

•Antifree-flowsafteyclamp

•Flow-StopCap

•PVC-free

•DEHPasplasticizerisnotused

•Latex-free

Packaging

• Casequantity:30x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyaone-waycheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON22 FXref.M46444251

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~145cm

15µmfilter

ProtectiveCap

Unventedfreeflex®spike

Robertsclamp

2xNeedle-freeaccess

Robertsclamp

Needle-freeaccess

TransparentIn-linedripchamber

Ventedspikewithantibacterialfilter

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock(sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Spikeablebagsnorbottlesinsideline

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON30ref.M46445900S

Approximate set length: 310cm

Approximate priming volume: 33ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~200cm

Rollerclamp

15µmfilter

3xYconnector

ProtectiveCap

4xRobertsclamp

3xfemaleLuerLockCap

3xRotatingmaleLuerLock

3-Way-Stopcock

TransparentIn-linedripchamber

Page 18: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

32 33

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

4xYconnector

2xRollerclamp

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock(sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON40ref.M46445100S

Approximate set length: 310cm

Approximate priming volume: 34ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~200cm

15µmfilter

Robertsclamp

2xProtectiveCap

2xVentedspikewithantibacterialfilter

3xRobertsclamp

3xfemaleLuerLockCap

3xRotatingmaleLuerLock

3-Way-Stopcock

TransparentIn-linedripchamber

Advantages

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON401ref.M46444001

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Ventedspikewithantibacterialfilter

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~140cm

Robertsclamp

4xNeedle-freeaccess

Rollerclamp

15µmfilter

Robertsclamp

Needle-freeaccess

TransparentIn-linedripchamber

Page 19: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

34 35

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Advantages

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42ref.M46444000S

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~140cm

15µmfilter

ProtectiveCap

Robertsclamp

4xNeedle-freeaccess

Ventedspikewithantibacterialfilter

TransparentIn-linedripchamber

Advantages

•Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

•Patientproximalaccessforemergencyapplication

•Antifree-flowsafteyclamp

•Flow-StopCap

•PVC-free

•DEHPasplasticizerisnotused

•Latex-free

Packaging

• Casequantity:25x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyaone-waycheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42 FXref.M46444051

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~145cm

Robertsclamp

4xNeedle-freeaccess

Rollerclamp

15µmfilter

Robertsclamp

Needle-freeaccess

Unventedfreeflex®spike

TransparentIn-linedripchamber

Page 20: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

36 37

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

OncologySets OncologySets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Advantages

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42 SCref.M46444061

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~150cm

Robertsclamp

4xNeedle-freeaccess

Rollerclamp

15µmfilter

Ventedspikewithantibacterialfilter

3-Way-Stopcock

TransparentIn-linedripchamber

4xRotatingmaleLuerLock

5xYconnector

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagswithfemaleLuerLock(sideline)

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON45ref.M46446700

Approximate set length: 280cm

Approximate priming volume: 34ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~170cm

15µmfilter

2xProtectiveCap

6xRobertsclamp

4xfemaleLuerLockCap

2xVentedspikewithantibacterial

filter

TransparentIn-linedripchamber

Page 21: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

38 39

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

0.2µmFilter0.2µmFilter

Advantages

• Providesaddititionalprotectionagainstbacterialcontamination

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugsrequiringa0.2μmfilter

• Infusionofdrugs/fluids

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Totalparenteralnutritionandotherlipidcontainingsolutions

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

•Primary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON70ref.M46444600S

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

length~170cm

Rollerclamp

Ventedspikewithantibacterialfilter

15µmfilter

TransparentIn-linedripchamber

Advantages

• Providesaddititionalprotectionagainstbacterialcontamination

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugsrequiringa0.2μmfilter

• Infusionofdrugs/fluids

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Totalparenteralnutritionandotherlipidcontainingsolutions

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

•Primary/secondarymodewithVolumatMCAgilia

VL ON72ref.M46444100S

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

Rollerclamp

15µmfilter

ProtectiveCap

Ventedspikewithantibacterialfilter

Needle-freeaccess

length~180cm

TransparentIn-linedripchamber

0.2µmantibacterialandaireliminatingfilter

(neutrallycharged)

0.2µmantibacterialandaireliminatingfilter

(neutrallycharged)

Page 22: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

40 41

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

LightProtectedSetsLightProtectedSets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Primary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON90ref.M46444900S

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

length~160cm

Rollerclamp

Transparentdripchamber

Ventedspikewithantibacterialfilter

15µmfilter

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Primary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON91ref.M46444901

Approximate set length: 255cm

Approximate priming volume: 24ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

Rollerclamp

Transparentdripchamber

15µmfilter

ProtectiveCap

Ventedspikewithantibacterialfilter

Needle-freeaccess

length~150cm

Robertsclamp

Page 23: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

42 43

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

LightProtectedSetsLightProtectedSets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofanydrugs/fluidsincludinglightsensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-availableinbagsorbottles

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyaone-waycheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON22 OPref.M46446000S

Approximate set length: 300cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

length~170cm

Protectivecap

Flow-StopCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeclip:antifree-flowsafetyclamp

15µmfilter

In-linetransparentdripchamber

2xNeedle-freeaccess

Robertsclamp

Ventedspikewithantibacterialfilter

RotatingmaleLuerLock

Rollerclamp

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON22 OP NFref.M46444230S

Approximate set length: 265cm

Approximate priming volume: 24ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~150cm

Transparentdripchamber

15µmfilter

ProtectiveCap

Robertsclamp

2xNeedle-freeaccess

Robertsclamp

Needle-freeaccess

Ventedspikewithantibacterialfilter

Robertsclamp

Rollerclamp

Page 24: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

44 45

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

LightProtectedSetsLightProtectedSets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42 OPref.M46445801

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~150cm

Transparentdripchamber

15µmfilter

ProtectiveCap

Robertsclamp

4xNeedle-freeaccess

Ventedspikewithantibacterialfilter

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42 OP NFref.M46444080S

Approximate set length: 275cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

ProtectiveCap

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~150cm

Robertsclamp

4xNeedle-freeaccess

Rollerclamp

Transparentdripchamber

15µmfilter

Robertsclamp

Ventedspikewithantibacterialfilter

Needle-freeaccess

Robertsclamp

Page 25: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

47AgiliaVolumatLines46

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

AgiliaVolumatLines

LightProtectedSets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:25x1

Typical applications

• Infusionofanydrugs/fluidsincludinglight-sensitivedrugs(includingUV-sensitivedrugs)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

Not to be used for / in

• Bloodcells

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/VolumatMCAgiliaVPMC

VL ON42 OP SCref.M46444071

Approximate set length: 270cm

Approximate priming volume: 26ml

Main materials: PUR(tubing:diameter3.0x4.1mm)PP(tubing:diameter2.94x4.02mm)Silicone(tubing:diameter3.41x5.11mm)

Flow-StopCap

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

length~150cm

Transparentdripchamber

15µmfilter

ProtectiveCap

Robertsclamp

4xNeedle-freeaccess

Ventedspikewithantibacterialfilter

3-Way-Stopcock

Notes to remember

Page 26: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

48 49

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sion

S

ets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

FilterLines200µmFilter

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• Bottles

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL TR00ref.M46442800S

Protectivecap

Flow-StopCap

Non-ventedspikeforbloodbags

Transparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL TR12ref.M46442700S

FilterLines200µmFilter

Protectivecap

Flow-StopCap

Transparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

length~170cm length~170cm

Page 27: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

50 51

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sion

S

ets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

FilterLines200µmFilter

Approximate set length: 290cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• Bottles

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL TR21ref.M46446200S

Protectivecap

Flow-StopCap

Non-ventedspike

In-linetransparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

RotatingmaleLuerLock

Robertsclamp

Approximate set length: 285cm

Approximate priming volume: 26ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL TR22ref.M46443000S

FilterLines200µmFilter

Protectivecap

Flow-StopCap

In-linetransparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Needle-freeaccess

RotatingmaleLuerLock

Robertsclamp

Ventedspikewithantibacterialfilter

length~170cm length~170cm

Page 28: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

52 53

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sion

S

ets

Ad

dit

ion

al

Info

rmat

ion

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

FilterLines200µmFilter

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• One-waycheckvalve

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

VL TR42ref.M46442900S

Protectivecap

Flow-StopCap

Transparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Needle-freeaccess

One-waycheckvalve

RotatingmaleLuerLock

Robertsclamp

Ventedspikewithantibacterialfilter

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• InfusionofdifferentdrugsinthesamesetwithuseofSecondaryLines

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Transfusionofbloodproductsavailableinbags

Not to be used for / in

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL TR43ref.M46444500S

FilterLines200µmFilter

Protectivecap

Flow-StopCap

Transparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Needle-freeaccess

RotatingmaleLuerLock

Robertsclamp

Ventedspikewithantibacterialfilter

length~170cm length~170cm

Page 29: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

54 55

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aren

tera

lN

utr

itio

nS

ets

Paed

iatr

ic

Set

sO

nco

log

y

Set

s

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 180cm

Approximate priming volume: 16ml

Main materials: PVC(tubing:diameter2.5x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Limitedprimingvolume60drops/ml

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

•Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

Not to be used for / in

•Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Notcompatiblewiththeoptionaldropsensor

VL PA02ref.M46442200S

Microbore

Protectivecap

Flow-StopCap

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Tubeadaptor

RotatingmaleLuerLock

15µmfilter

Needle-freeaccess

Ventedspikewithantibacterialfilter

BuretteSets

Approximate set length: 300cm

Approximate priming volume (without burette’s volume): 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Allowstheinfusionofapreciselyknownvolumevia150mlgraduatedburette

• Allowsthemixingofdifferentfluids/drugsintheburette

• 20drops/ml

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:10x1

Typical applications

• Infusionofaprecisevolumeoutofabagorbottle

• Mixingandaddingofdrugsintotheburette

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Notcompatiblewiththeoptionaldropsensor

VL PA92ref.M46445200S

---------------

Protectivecap

Flow-StopCap

150mlgraduatedburette

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Transparentdripchamber

RotatingmaleLuerLock

15µmfilter

RobertsClamp

Needle-freeaccess

Ventedspikewithantibacterialfilter

length~110cm length~170cm

Page 30: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

56 57

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aren

tera

lN

utr

itio

nS

ets

Paed

iatr

ic

Set

sO

nco

log

y

Set

s

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 300cm

Approximate priming volume (without burette’s volume): 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Allowstheinfusionofapreciselyknownvolumevia150mlgraduatedburette

• Allowsthemixingofdifferentfluids/drugsintheburette

• 20drops/ml

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:10x1

Typical applications

• Infusionofaprecisevolumeoutofabagorbottle

• Mixingandaddingofdrugsintotheburette

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Notcompatiblewiththeoptionaldropsensor

VL PA93ref.M46443800S

BuretteSets

---------------

Protectivecap

Flow-StopCap

150mlgraduatedburette

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Transparentdripchamber

RotatingmaleLuerLock

15µmfilter

RollerClampNeedle-freeaccess

Ventedspikewithantibacterialfilter

BuretteSets

Approximate set length: 300cm

Approximate priming volume (without burette’s volume): 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Allowstheinfusionofapreciselyknownvolumevia150mlgraduatedburettewithswimmervalve

• Allowsthemixingofdifferentfluids/drugsintheburette

• 60drops/ml

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:10x1

Typical applications

• Infusionofaprecisevolumeoutofabagorbottle

• Mixingandaddingofdrugsintotheburette

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Notcompatiblewiththeoptionaldropsensor

VL PA94ref.M46445300S

---------------

Protectivecap

Flow-StopCap

150mlgraduatedburettewithswimmervalve

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Transparentdripchamber

RotatingmaleLuerLock

15µmfilter

RollerClamp

Needle-freeaccess

Hanger

Ventedspikewithantibacterialfilter

length~170cm length~170cm

Page 31: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

58 59

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

sP

are

nte

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 290cm

Approximate priming volume: 25ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Providesadditionalprotectionagainstbacterialcontamination

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–availableinbagsorbottles(mainline)

–havingnoparticularincompatibility

•Infusionofdrugsrequiringa1.2µmfilter

• Canbeusedforparenteralnutrition

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL PN02ref.M46444400S

FilterLines1.2µmFilter

Protectivecap

Flow-StopCap

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

0.2µmantibacterialandaireliminatingfilter(neutrallycharged)

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

FilterLines1.2µmFilter

Approximate set length: 285cm

Approximate priming volume: 26ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Providesadditionalprotectionagainstbacterialcontamination

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

–availableinbagsorbottles(mainline)

–havingnoparticularincompatibility

•Infusionofdrugsrequiringa1.2µmfilter

• Canbeusedforparenteralnutrition

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL PN00ref.M46444300S

Protectivecap

Flow-StopCap

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

0.2µmantibacterialandaireliminatingfilter(neutrallycharged)

RotatingmaleLuerLock

Ventedspikewithantibacterialfilter

length~170cm

length~180cm

Page 32: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

60 61

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

sP

are

nte

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

Approximate set length: 280cm

Approximate priming volume: 26ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• PossibleusewithbagsequippedwithLuerLockconnector

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• InfusionofdrugspresentedinbagsequippedwithaLuerLockconnector(maleorfemale)

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• Canbeusedforparenteralnutrition

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL PN20ref.M46443700S

SpecialApplication

Protectivecap

FemaleLuerLock

FemaleLuerLock

MaleLuerLock

Flow-StopCap

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

RotatingmaleLuerLock

15µmfilter

Robertsclamp

freeflex®SpikeLine

Approximate set length: 280cm

Approximate priming volume: 26ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

• Providesadditionalprotectionagainstbacterialcontamination

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugsrequiringa1.2µmfilter

• Canbeusedforparenteralnutrition

• Infusionofdrugs/fluidshavingnoparticularincompatibility

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL PN00 FXref.M46442300S

Protectivecap

Flow-StopCap

Unventedfreeflex®spike

Transparentdripchamber

15µmfilter

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

0.2µmantibacterialandaireliminatingfilter(neutrallycharged)

RotatingmaleLuerLock

length~170cm length~170cm

Page 33: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

62 63

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

sP

aren

tera

lN

utr

itio

nS

ets

AgiliaVolumatLinesAgiliaVolumatLines

FilterLines200µmFilter

Approximate set length: 290cm

Approximate priming volume: 30ml

Main materials: PVC(tubing:diameter3.0x4.1mm)Silicone(tubing:diameter3.41x5.11mm)

Advantages

• 200µmfilter

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-availableinbagsorbottles

-havingnoparticularincompatibility

• Transfusion

• Secondaryinfusion

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

Not to be used for / in

• InfusionofdrugsknowntobeincompatiblewithPVC(e.gtrinitrine,isosorbidedinitrate,sodiumnitroprussiate…)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL SP22ref.M46443100S

2xProtectivecap

Flow-StopCap

Transparentdripchamber

200µmbloodfilter(surface>10cm2)

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

Yconnector

RotatingmaleLuerLock

2xRobertsclamp

2xVentedspikewithantibacterialfilter

Approximate set length: 285cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1)PP(tubing:diameter2.94x4.02)Silicone(tubing:diameter3.41x5.11)

Advantages

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

• Needle-freeaccess.Shouldnotbeusedtoconnectagravityline(unlessitisprotectedbyabackcheckvalve)

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL SP62ref.M46443400S

PrimaryLine

Protectivecap

Flow-StopCap

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

15µmfilter

Ventedspikewithantibacterialfilter

length~170cm length~170cm

RotatingmaleLuerLock

Page 34: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

64 65

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

eco

nd

ary

Set

sS

pec

ial

Set

sP

aed

iatr

ic

Set

sO

nco

log

y

Set

sS

tan

dar

d&

P

rim

ary

Set

sP

aren

tera

lN

utr

itio

nS

ets

AgiliaVolumatLinesAgiliaVolumatLines

LightProtectedTubing

Approximate set length: 270cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1)PP(tubing:diameter2.94x4.02)Silicone(tubing:diameter3.41x5.11)

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL SP90ref.M46443500S

Protectivecap

Flow-StopCap

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

MaleLuerLock

15µmfilter

Ventedspikewithantibacterialfilter

Approximate set length: 290cm

Approximate priming volume: 25ml

Main materials: PUR(tubing:diameter3.0x4.1)PP(tubing:diameter2.94x4.02)Silicone(tubing:diameter3.41x5.11)

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Patientproximalaccessforemergencyapplication

• Antifree-flowsafetyclamp

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:30x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-availableinbagsorbottles

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

Not to be used for / in

• Bloodcells

• Primary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

VL SP92ref.M46443600S

LightProtectedTubing

Protectivecap

Flow-StopCap

Transparentdripchamber

Rollerclamp

Greenconnector

Calibratedsiliconepumpingsegment

BlueSafeClip:antifree-flowsafetyclamp

Needle-freeaccess

MaleLuerLock

15µmfilter

Ventedspikewithantibacterialfilter

length~170cm length~180cm

Page 35: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

66 67

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

econ

dary

S

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

SecondarySets SecondarySets

Approximate set length: 38cm

Approximate priming volume: 2ml

Main materials: PUR(tubing:diameter3.0x4.1)

Approximate set length: 48cm

Approximate priming volume: 5ml

Main materials: PUR(tubing:diameter3.0x4.1)

Advantages

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:60x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

Advantages

• Providesadditionalprotectionagainstbacterialcontamination

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:40x1

Typical applications

• Infusionofdrugsrequiringa0.2μmfilter

•Infusionofdrugs/fluids –havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Totalparenteralnutritionandotherlipidcontainingsolutions

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SLref.M77460020

SL Filterref.M77460025

Flow-StopCap

Protectivecap

MaleLuerLock

Robertsclamp

Ventedspikewithantibacterialfilter

Flow-StopCap

Protectivecap

MaleLuerLock

Robertsclamp

0.2μmantibacterialandaireliminatingfilter

(neutrallycharged)

Ventedspikewithantibacterialfilter

length~30cm length~30cm

Page 36: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

68 69

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

econ

dary

S

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

SecondarySets

Approximate set length: 78cm

Approximate priming volume: 7ml

Main materials: PUR(tubing:diameter3.0x4.1)

Advantages

• Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

• Providesadditionalprotectionagainstbacterialcontamination

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:40x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugsrequiringa0.2μmfilter

• Infusionofdrugs/fluids –havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• Totalparenteralnutritionandotherlipidcontainingsolutions

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL FX Filterref.M77460026

SecondarySets

Approximate set length: 65cm

Approximate priming volume: 10ml

Main materials: PUR(tubing:diameter3.0x4.1)

Advantages

• Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:50x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL 20 FX NDref.M77460033

Flow-StopCap

Protectivecap

MaleLuerLock

Robertsclamp

0.2μmantibacterialandaireliminatingfilter

(neutrallycharged)

Unventedfreeflex®spike

length~70cm

Protectivecap

Flow-StopCap

Unventedfreeflex®spike

Rollerclamp

Transparentdripchamberwithnoliquidfilter

RotatingmaleLuerLock

length~50cm

Page 37: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

70 71

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

econ

dary

S

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

SecondarySets SecondarySets

Advantages

• Tightandsecureconnectionwithfreeflex®/freeflex®+,ensuringapermanentconnectionavoidingspillages

• One-waycheckvalve

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:60x1

Typical applications

• OnlyusewithFreseniusKabifreeflex®/freeflex®+Bags

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bottles

• Standardbags

• Bloodcells

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL 00 FXref.M77460062

Approximate set length: 45cm

Approximate priming volume: 2.5ml

Main materials: PUR(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

ProtectiveCap

length~40cm

Unventedfreeflex®spike

One-waycheckvalve

Advantages

• Flow-StopCap

• DEHPasplasticizerisnotused

• Latex-free

• SecondaryhangertohangtheprimarybaglowerthentheSecondaryInfusion

Packaging

• Casequantity:40x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–availableinbagsorbottles

–havingnoparticularincompatibility

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• InfusionofdrugsknowntobeincompatiblewithPVC(e.g.trinitrine,isosorbidedinitrate,sodiumnitroprussiate...)

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL 00 DCref.M77460037

Approximate set length: 85cm

Approximate priming volume: 12ml

Main materials: PVC(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

ProtectiveCap

length~85cm

Ventedspikewithantibacterialfilter

Transparentdripchamber

15µmfilter

Rollerclamp

Secondaryhanger

Page 38: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

72 73

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

econ

dary

S

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

SecondarySets SecondarySets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• One-waycheckvalve

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:60x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

SL 00 OPref.M77460065

Approximate set length: 45cm

Approximate priming volume: 2.5ml

Main materials: PUR(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

ProtectiveCap

length~40cm

One-waycheckvalve

Ventedspikewithantibacterialfilter

Advantages

• Invertedport

• One-waycheckvalve

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:60x1

Typical applications

• Infusionofdrugs/fluids

–havingnoparticularfiltrationrequirements

–havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bottles

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL IPref.M77460069

Approximate set length: 43cm

Approximate priming volume: 2.6ml

Main materials: PUR(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

ProtectiveCap

One-waycheckvalve

length~40cm

Ventedspikewithantibacterialfilter

Needle-freeaccess

Page 39: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

74 75

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Duetoourpolicyofcontiniousproductimprovement,aswellaschangesinstandards,thefeaturesdescribedinthisdocumentmaychange.Pleaseconsultusforthemostcurrentinformation.

Tran

sfu

sio

n

Set

sA

dd

itio

nal

In

form

atio

nS

econ

dary

S

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLinesAgiliaVolumatLines

SecondarySets SecondarySets

Advantages

• ThelinefilterslightintheUVrangeof250/350nmforlightsensitivedrugs

• Invertedport

• One-waycheckvalve

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:60x1

Typical applications

• Infusionofdrugs/fluids

-havingnoparticularfiltrationrequirements

-havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

SL OP IPref.M77460068

Approximate set length: 43cm

Approximate priming volume: 2.6ml

Main materials: PUR(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

ProtectiveCap

length~40cm

One-waycheckvalve

Ventedspikewithantibacterialfilter

Needle-freeaccess

Advantages

• Providesadditionalprotectionagainstbacterialcontamination

• Invertedport

• One-waycheckvalve

• Flow-StopCap

• PVC-free

• DEHPasplasticizerisnotused

• Latex-free

Packaging

• Casequantity:40x1

Typical applications

• Infusionofdrugsrequiringa0.2μmfilter

•Infusionofdrugs/fluids –havingnoparticularincompatibility

• InfusionofdrugsnoncompatiblewithPVC

• Manualprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• Automaticprimary/secondarymodewithVolumatMCAgilia/AgiliaVPMC

• SecondaryInfusion

Not to be used for / in

• Bloodcells

• Totalparenteralnutritionandotherlipidcontainingsolutions

• Lightsensitivedrugs(unlessotherprecautionsaretakentoprotectthedrugagainstdirectlight)

SL Filter IPref.M77460070

Approximate set length: 43cm

Approximate priming volume: 5.3ml

Main materials: PUR(tubing:diameter3.0x4.1mm)

Flow-StopCap

RotatingmaleLuerLock

Robertsclamp

ProtectiveCap

One-waycheckvalve

length~40cm

Ventedspikewithantibacterialfilter

Needle-freeaccess

0.2μmantibacterialandaireliminatingfilter

(neutrallycharged)

Page 40: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

76 77

Tran

sfu

sio

n

Set

sA

ddit

ion

al

Info

rmati

on

Sec

on

dar

y S

ets

Sp

ecia

l S

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

y S

ets

Par

ente

ral

Nu

trit

ion

Set

s

Agilia Volumat LinesAgilia Volumat Lines76

Additional Information

Setsbyreferences 78

Primingofthesetusedwithabag/bottle 79

Handlingrecommendation 80

Installation/Deinstallationoftheinfusionset 82

CompatibilitywithotherAgiliaPumps 83

SpecificFeatures 84

AgiliaVolumatLines

Page 41: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

79

Addit

ion

al

Info

rmati

on

On

colo

gy

S

ets

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Par

ente

ral

Nu

trit

ion

Set

sP

aed

iatr

ic

Set

sTr

ansf

usi

on

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

AgiliaVolumatLines78 Agilia Volumat Lines

REFERENCE DESIGNATION PAGE

Microbore

VLPA02 M46442200S 54

Burette Lines

VLPA92 M46445200S 55

VLPA93 M46443800S 56

VLPA94 M46445300S 57

ParenteralNutritionSets

1.2 µm Filter

VLPN00 M46444300S 58

VLPN02 M46444400S 59

Special Application

VLPN20 M46443700S 60

Freeflex® Spike Line

VLPN00FX M46442300S 61

SpecialSets

200 µm Filter

VLSP22 M46443100S 62

Primary Line

VLSP62 M46443400S 63

Light Protected Tubing

VLSP90 M46443500S 64

VLSP92 M46443600S 65

SecondarySets

SL M77460020 66

SLFILTER M77460025 67

SLFXFILTER M77460026 68

SL20FXND M77460033 69

SL00DC M77460037 70

SL00FX M77460062 71

SL00OP M77460065 72

SLIP M77460069 73

SLOPIP M77460068 74

SLFilterIP M77460070 75

1 Introducethespikerightdownintothe

bag(rollerclampopen–airinletclosed).

2 Pressthebaginordertoremovetheair,

andfillthedripchamberuptohalfofits

capacity.

1

2 4

3

12

3

5

4

1 Introducethespikerightdowninto

thebottle(rollerclampopen–

airinletclosed).

2 Closetherollerclamp.

3 Hangthebottleupsidedown,then

pressthedripchamberinordertofill

itto~halfofitscapacity.

3 Hangthebagupsidedown,andletthe

liquidflowintotheset.

4 Oncethesetiscompletelyprimed,close

therollerclampandcheckabsenceofair

bubbles.

1

2 4

3

12

3

5

4

Priming of the set used with a bag

Priming of the set used with a bottle

4 Opentherollerclamp.

5 Opentheairinlet,andlettheliquid

flowintotheset.

6 Oncethesetiscompletelyprimed,

closetherollerclampandcheck

absenceofairbubbles.

Sets by reference

REFERENCE DESIGNATION PAGE

StandardandPrimarySets

VLST00 M46441000S 16

VLST10 M46441300S 17

VLST01 M46441600S 18

VLST02 M46441900S 19

VLST02ND M46441980 20

VLST22 M46442500S 21

VLST42 M46442600S 22

VLST44 M46443200 23

OncologySets

VLON10 M46445500S 24

VLON11 M4643900 25

VLON12 M4644800 26

VLON15 M46446600 27

VLON20 M46445700S 28

VLON22 M46444200 29

VLON22FX M46444251 30

VLON30 M46445900S 31

VLON40 M46445100S 32

VLON401 M46444001 33

VLON42 M46444000S 34

VLON42FX M46444051 35

VLON42SC M46444061 36

VLON45 M46446700 37

VLON70 M46444600S 38

VLON72 M46444100S 39

VLON90 M46444900S 40

VLON91 M46444901 41

VLON22OP M46446000S 42

VLON22OPNF M46444230S 43

VLON42OP M46445801 44

VLON42OPNF M46444080S 45

VLON42OPSC M46444071 46

TransfusionSets–200µmFilter

200 µm Filter

VLTR00 M46442800S 48

VLTR12 M46442700S 49

VLTR21 M46446200S 50

VLTR22 M46443000S 51

VLTR42 M46442900S 52

VLTR43 M46444500S 53

Page 42: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

81

Tran

sfu

sio

n

Set

sA

ddit

ion

al

Info

rmati

on

Sec

on

dar

yS

ets

Sp

ecia

lS

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

yS

ets

Par

ente

ral

Nu

trit

ion

Set

s

AgiliaVolumatLines80 AgiliaVolumatLines

Disinfectneedle-freeaccessportoftheAdministrationSet(MainLine).

AttachconnectorofSecondaryLinetoneedle-freeaccessportoftheAdministrationSet.

Prepareforstartofinfusionaccordingtolocalprotocolandmanufacturersguidelineforrespectivepumpinuse.

AttachconnectorofAdministrationSettopatientaccesssite.Considerlocalprotocolfortheprocedure.

BeforestartingtheprocessopentherollerclampoftheAdministrationSet.

CloseupperclampoftheAdministrationSet.

Spikecontainer.

Turninfusionbagandportupsidedown(180°),openupperclampagain.

HoldthedripchamberoftheAdministrationSetabovetheportoftheinfusionbag.

PressinfusionbaguntilthedripchamberoftheAdministrationSetisfilledto1/3.ThenhanginfusionbagoninfusionstandandprimeAdministrationSetcompletely.Flow-StopCapwillpreventleakage.

CloseupperclampandrollerclampofAdministrationSet.

1/3

Handling recommendation of Standard Lines

Handling recommendation of Standard and Inverted Port

B:Invertedport

CloseclampofSecondaryLine.

RemovecapfromthespikeoftheSecondaryLineandspikeinfusionbag.

OpenclampofSecondaryLine.

Turninfusionbagup-side-ownandpressituntiltheScondaryLineiscompletelyde-airedandfilledwithneutralsolution.

AttachconnectorofSecondaryLinetoneedle-freeaccessportoftheAdministrationSet.

CloseclampofSecondaryLine.

Remark:Openclampofthecontainerwhichwillbeused,closetheotherone.

CloseclampofSecondaryLine.

RemovecapfromthespikeoftheSecondaryLineandspikeinfusionbag.

TurnportupsidedownandopentheclampoftheSecondaryLine.

PressinfusionbaguntiltheSecondaryLineiscomple-telydeairedandfilledwithneutralsolution.

CloseclampofSecondaryLine.Besurethattheclampisplacednexttotheneedle-freeaccess.Donotopenclampduringtheprocessagain!Itremainsclosed!

Disinfectneedle-freeaccessport.

Connectsyringetoneedle-freeaccessport.

Withdrawdesiredamountoffluidforflushing.

DisinfectportatSecondaryLine.

Spikevialwithchemo-spike.

Withdrawcalculatedvolumeofcytostaticdrug.

Disinfectneedle-freeaccessport.

Connectsyringewithcytostaticdrugtoneedle-freeaccessportandinjectfluid.

Disinfectneedle-freeaccessportatSecondaryLine.

Takeflushsyringe,connecttoneedle-freeaccessportandflushsystem.

A:Standard

Page 43: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

83

Tran

sfu

sio

n

Set

sA

ddit

ion

al

Info

rmati

on

Sec

on

dar

y S

ets

Sp

ecia

l S

ets

Pae

dia

tric

S

ets

On

colo

gy

S

ets

Sta

nd

ard

&

Pri

mar

y S

ets

Par

ente

ral

Nu

trit

ion

Set

s

Agilia Volumat Lines82 AgiliaVolumatLines

1 Openthepumpdoorbyliftingthedoorlever.

Note: The pump automatically switches

on when connected to mains. If not, press

the <ON> key. An auto-test checks the

functionality of the pump. Make sure that all

LEDs and buzzers are activated.

2 Oncetheauto-testisOK,analarmscreen

appearstoindicatethatyoucanstart

installingthetubingset.

Note: The flashing red leds indicate that it

is an alarm. If no action is taken within 2

minutes, an audible signal will sound. Press

the <SILENCE ALARM> key.

1.Alignthetubingsethorizontallyalongthe

tubeguidessothatthegreenconnectoris

positionedtotheright(green)andtheblue

clampispositionedinfrontoftheclamp

guide(blue).

To the patient hTo the container

VolumatadministrationsetscanbeusedwiththeVolumatAgiliaPumps:

BRANDNAMESOFTHEMODELSCOMPATIBLEWITHIEC60601ED2,INTRODUCEDFROM2007

•VolumatAgilia,VolumatMCAgilia

BRANDNAMESOFTHEMODELSCOMPATIBLEWITHIEC60601ED2ANDED3,INTRODUCEDFROM2016

•AgiliaVP,AgiliaVPMC,AgiliaVPMCWifi

BRANDNAMESOFTHEMODELSCOMPATIBLEWITHIEC60601ED2ANDED3INTRODUCEDFROM2013•VolumatMCAgiliaUS

1 Removetheset

bypullingonthe

safetyclampand

ontheadminis-

trationset.

2.Insertthegreenconnectorintothe

greenslot.

3.PositiontheblueSafeClipinitsblueslot

andthenpushtheclamptolocatethe

sphericalhingeintoplace.

4.Ensurethatthetubeisinthelefttube

guide,thenpushthedoorlevertoclose

thepumpdoor.

3 OcclusivityCheckSystemautomatically

clampstheline,activatesrealpumping

andcheckspressureincrease.

The OCS-test checks the right set

positionning and pump occlusivity, thus

securing the pump against the risk of

free-flow.

4 Placethecontainerawayfromthe

pump.Thecontainershouldbeplaced

20to80cmabovethepump(h).

2 ReleasetheSafeClip.

Deinstallation of the infusion set

clampedreleased

Installation of the infusion set

Compatibility with Agilia Pumps

Page 44: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

84 AgiliaVolumatLines

Function Generalinformation Specifichandling

Filters

• Preventionofinfusionofunwantedparticlesandorganismsaswellassmallamountsofair

• Providingadditionalprotectionagainstbacterialcontamination

• Hydrophobicandhydrophilicmembrane

• Hydrophobicmembrane:–Seperatesairfromthefluid–Venttheairoutofthesystem throughholes–Sizeofmembranes0.02μm

• Hydrophilicmembrane:–Leadsthefluidthroughthefilter andkeepsitinthesystem–Sizeofthemembrane0.2μm

Primingneedstobedoneinflow-directionoffilter.

PVC-freetubing

• Preventionofadsorptionorabsorptionofdrug(in)totubeaswellasleachingofplasticizerfromtube

• Adsorption,absorption,orleachingofPVCmightleadto:–Lossofdrugconcentration–Accidentalinfusionofplasticizer

Needle-freeaccess

• IVaccessdeviceforneedle-freeinjectionandinfusionviaaSecondaryLineand/orneedle-freesyringe

• One-directionalvalve

• Infusionpressure:–upto2bar

• Maximumflowrate:–10.900ml/hour(183ml/min)

• Doublesealed;noairentranceduringactivation

• Testedfor72husageand72activations

Primingneedstobedonewithneedle-freeaccessupsidedown.

freeflex®infusionline

• Guaranteesapermanentconnectionbetweenthefreeflex® /

freeflex®+,ensuringaclosedsystem

Thefreeflex®portfoliowithfreeflex®infusionlines,freeflex®spike,freeflex®andfreeflex®+allowsthefollowingfeatures:

• Secureandtightconnectiontothebag

• Easytopiercewithlowriskofinjury

• Colorcode:„bluetoblue“

• Pleaseuselinesequippedwiththefreeflex®settofullygainadvantagesoftheclosedsystem

• freeflex®systemcanavoidaccidentaldisconnectionandpreventcontaminationwithcytostatics

free

Specific Features Function, information and handling

85AgiliaVolumatLines

Notes to remember

Page 45: Volumat Lines - fannin.euThis brochure may contain inaccuracies or typographical errors. Modifications may thus be made and will be included in later editions. As standards and equipment

Notes to remember

86 AgiliaVolumatLines