volume 6141 medical imaging 2006: visualization, image ...spie.org/toc/cds205.pdf · augmented...
TRANSCRIPT
Volume 6141 Medical Imaging 2006: Visualization, Image-Guided Procedures, and Display
Chairs/Editors: Kevin R. Cleary, Robert L. Galloway, Jr.
Conference Committee
AUGMENTED REALITY AND VIRTUAL COLONOSCOPY AND ENDOSCOPY
Image-based rendering method for mapping endoscopic video onto CT-based endoluminal views [6141-1]
L. Rai, W. Higgins
Dual modality virtual colonoscopy workstation: design, implementation, and preliminary evaluation [6141-2]
D. Chen, M. Meissner
Development of a navigation system for endoluminal brachytherapy in human lungs [6141-3]
I. Wegner, M. Vetter, M. Schoebinger, I. Wolf, H. Meinzer
Augmented reality visualization for thoracoscopic spine surgery [6141-4]
F. Sauer, S. Vogt, A. Khamene, S. Heining, E. Euler, M. Schneberger, K. Zuerl, W. Mutschler
Simulation of guide-wire navigation in complex vascular structures [6141-5]
V. Guilloux, P. Haigron, C. Goksu, C. Kulik, A. Lucas
VISUALIZATION AND RENDERING
A novel visualization method for the ribs within chest volume data [6141-6]
A. Kiraly, S. Qing, H. Shen
Visualizing the beating heart: interactive direct volume rendering of high-resolution CT time seriesusing standard PC hardware [6141-7]
H. Lehmann, O. Ecabert, D. Geller, G. Kiefer, J. Weese
Fast maximum intensity projection with 3D nonlinear wavelets [6141-8]
M. Héritier, R. Noumeir
Representation and visualization of variability in a 3D anatomical atlas using the kidney as an example[6141-9]
S. Hacker, H. Handels
Visualization of tumor-influenced 3D lung dynamics [6141-10]
A. Santhanam, C. Fidopiastis, K. Langen, S. Meeks, P. Kupelian, L. Davis, J. Rolland
Surface reconstruction from orthogonal contours [6141-11]
H. Zhang, J. Nosher, P. Yim
REGISTRATION AND SEGMENTATION
Robust surface registration using salient anatomical features in image-guided liver surgery [6141-12]
L. Clements, D. Cash, W. Chapman, R. Galloway, Jr., M. Miga
A realistic simulation framework for assessing deformable slice-to-volume (CT-fluoroscopy/CT) registration[6141-13]
Z. Yaniv, R. Stenzel, K. Cleary, F. Banovac
Shape-based segmentation and visualization techniques for evaluation of atherosclerotic plaques incoronary artery disease [6141-14]
D. Rinck, S. Krüger, A. Reimann, M. Scheuering
Image segmentation and registration for the analysis of joint motion from 3D MRI [6141-15]
Y. Hu, D. Haynor, M. Fassbind, E. Rohr, W. Ledoux
ELECTROMAGNETIC TRACKING AND OPEN SOURCE SOFTWARE
Assesment of metallic distortions of an electromagnetic tracking system [6141-17]
S. Kirsch, C. Schilling, G. Brunner
Method for estimating dynamic EM tracking accuracy of surgical navigation tools [6141-18]
C. Nafis, V. Jensen, L. Beauregard, P. Anderson
Fluoroscopy based accuracy assessment of electromagnetic tracking [6141-19]
Z. Yaniv, K. Cleary
A system for rapid prototyping of hearts with congenital malformations based on the medical imaginginteraction toolkit (MITK) [6141-20]
I. Wolf, T. Böttger, U. Rietdorf, D. Maleike, G. Greil, L. Sieverding, S. Miller, S. Mottl-Link, H. Meinzer
Comprehensive, powerful, efficient, intuitive: a new software framework for clinical imaging applications[6141-21]
K. Augustine, D. Holmes III, D. Hanson, R. Robb
Creation of 4D imaging data using open source image registration software [6141-22]
K. Wong, L. Ibanez, T. Popa, K. Cleary
ULTRASOUND
Percutaneous scaphoid pinning using ultrasound guidance [6141-23]
M. Beek, P. Abolmaesumi, T. Chen, R. Sellens, D. Pichora
A hybrid deformable model for simulating prostate brachytherapy [6141-24]
D. Levin, A. Fenster, H. Ladak
Assessing the feasibility of ultrasound-initialized deformable bone models [6141-25]
H. Talib, K. Rajamani, J. Kowal, M. Styner, M. González Ballester
3D segmentation of kidney tumors from freehand 2D ultrasound [6141-26]
A. Ahmad, D. Cool, B. Chew, S. Pautler, T. Peters
3D ultrasound image guidance system used in RF uterine adenoma and uterine bleeding ablation system[6141-27]
M. Ding, X. Luo, C. Cai, C. Zhou, A. Fenster
DISPLAY
Temporal response measurements of medical liquid crystal displays [6141-29]
H. Liang, A. Badano
Performance evaluation of a commercial system for quantitative measurement of display resolution [6141-30]
E. Cleland, E. Samei
Optimizing the image contrast on the softcopy displays [6141-31]
J. Fan, H. Roehrig, M. Sundareshan, E. Krupinski
MODELING
Image stabilisation of the beating heart by local linear interpolation [6141-32]
M. Gröger, G. Hirzinger
Exponential elastic model and its application in real-time simulation [6141-33]
H. Zhong, T. Peters
Pre-operative simulation and post-operative validation of soft-tissue deformations for breast implantationplanning [6141-34]
L. Roose, W. De Maerteleire, W. Mollemans, F. Maes, P. Suetens
An optimal three-stage method for anatomical shape reconstruction from sparse information using adense surface point distribution model [6141-36]
G. Zheng, K. Rajamani
NAVIGATION AND LOCALIZATION
Integration of real-time x-ray fluoroscopy, rotational x-ray imaging, and real-time catheter tracking forimproved navigation in interventional cardiac electrophysiology procedures [6141-37]
R. Manzke, R. Chan, G. Shechter, S. Sokka, D. Stanton, Z. Malchano, V. Rasche, V. Reddy
Targeted endomyocardial injections of therapeutic cells using x-ray fused with MRI guidance [6141-38]
L. Gutiérrez, R. de Silva, E. McVeigh, C. Ozturk, R. Lederman
Endoscopic navigation system using 2D/3D registration [6141-39]
J. Hummel, M. Figl, H. Bergmann, W. Birkfellner
Minimization of tool tracking error using fulcrum correction in minimally invasive interventions: applicationto prostate biopsy procedure [6141-40]
D. Cool, S. Sherebrin, J. Izawa, T. Peters, A. Fenster
REGISTRATION, MODELING, AND SEGMENTATION
Rapid registration of multimodal images using a reduced number of voxels [6141-42]
X. Huang, N. Hill, J. Ren, T. Peters
A piecewise function-to-structure registration algorithm for image-guided cardiac catheter ablation [6141-43]
Y. Su, D. Holmes III, M. Rettmann, R. Robb
3D soft tissue predictions with a tetrahedral mass tensor model for a maxillofacial planning system: aquantitative validation study [6141-44]
W. Mollemans, F. Schutyser, N. Nadjmi, F. Maes, P. Suetens
A Laplace equation approach for shape comparison [6141-45]
E. Pichon, D. Nain, M. Niethammer
Automatic anatomical segmentation of the liver by separation planes [6141-46]
D. Boltcheva, N. Passat, V. Agnus, M. Jacob-Da Col, C. Ronse, L. Soler
Tumor volume measurement and volume measurement comparison plug-ins for VolView using ITK [6141-47]
T. Popa, L. Ibanez, E. Levy, A. White, J. Bruno, K. Cleary
NEUROSURGERY
XFEM-based modeling of successive resections for preoperative image updating [6141-48]
L. Vigneron, P. Robe, S. Warfield, J. Verly
Comparative study of brain deformation estimation methods [6141-49]
F. Liu, K. Paulsen, K. Lunn, H. Sun, A. Hartov, Z. Wu, D. Roberts
Integration of patient specific modeling and advanced image processing techniques for image-guidedneurosurgery [6141-50]
N. Archip, A. Fedorov, B. Lloyd, N. Chrisochoides, A. Golby, P. Black, S. Warfield
Automated brain shift correction using a pre-computed deformation atlas [6141-51]
P. Dumpuri, R. Thompson, T. Sinha, M. Miga
RADIATION ONCOLOGY AND OTHER
Incorporating seed orientation in brachytherapy implant reconstruction [6141-53]
Y. Zhou, A. Jain, G. Chirikjian, G. Fichtinger
A perspective matrix-based seed reconstruction algorithm with applications to C-arm based intra-operativedosimetry [6141-54]
S. Narayanan, P. Cho
Rapid prototype modeling in a multimodality world [6141-55]
L. Bidaut, J. Madewell, A. Yasko
3D ultrasound-based patient positioning for radiotherapy [6141-56]
M. Wang, R. Rohling, N. Archip, B. Clark
CT fluoroscopy-guided robotically-assisted lung biopsy [6141-57]
S. Xu, G. Fichtinger, R. Taylor, F. Banovac, K. Cleary
Stochastic modeling, virtual refinement, and deterministic fabrication of tissue engineering scaffolds[6141-58]
S. Rajagopalan, R. Robb
DISPLAY POSTER SESSION
A virtual image chain for perceived image quality of medical display [6141-60]
C. Marchessoux, J. Jung
Measurement of MTFs for monochrome and color liquid crystal displays [6141-61]
A. Horii, M. Takamura, K. Ichikawa, Y. Kodera, M. Ikeda, T. Ishigaki
IMAGE-GUIDED PROCEDURES POSTER SESSION
Magnetic resonance imaging for image-guided implantology [6141-63]
G. Eggers, B. Kress, J. Fiebach, M. Rieker, D. Spitzenberg, R. Marmulla, H. Dickhaus, J. Mühling
Electromagnetic tracker accuracy in the CyberKnife suite [6141-64]
E. Wilson, R. Slack, F. Banovac, S. Dieterich, H. Zhang, K. Cleary
Multimodal augmented reality system for surgical microscopy [6141-65]
J. Garcia Giraldez, H. Talib, M. Caversaccio, M. Gonzalez Ballester
Near-infrared imaging and structured light ranging for automatic catheter insertion [6141-66]
V. Paquit, J. Price, R. Seulin, F. Mériaudeau, R. Farahi, K. Tobin, Jr., T. Ferrell
Feasibility study for image guided kidney surgery: assessment of required intraoperative surface foraccurate image to physical space registrations [6141-67]
A. Benincasa, L. Clements, S. Herrell, S. Chang, M. Cookson, R. Galloway
Computerized fluoroscopy with zero-dose image updates for minimally invasive femoral diaphysealfracture reduction [6141-68]
G. Zheng, X. Dong
An effective technique for calibrating the intrinsic parameters of a vascular C-arm from a planar target[6141-69]
S. Gorges, E. Kerrien, M. Berger, Y. Trousset, J. Pescatore, R. Anxionnat, L. Picard
Noninvasive CT to Iso-C3D registration for improved intraoperative visualization in computer assistedorthopedic surgery [6141-70]
T. Rudolph, L. Ebert, J. Kowal
IGSTK: framework and example application using an open source toolkit for image-guided surgeryapplications [6141-71]
P. Cheng, H. Zhang, H. Kim, K. Gary, M. Blake, D. Gobbi, S. Aylward, J. Jomier, A. Enquobahrie, R. Avila, L. Ibanez, K. Cleary
MODELING POSTER SESSION
Volumetric CT measurement of the ischial tuberosities for designing analytical models of decubitus ulcers[6141-73]
D. Holmes III, R. Robb
Segmentation of the left and right cardiac ventricle using a combined bi-temporal statistical model [6141-74]
D. Fritz, D. Rinck, R. Dillmann, M. Scheuering
Computational flow dynamics in patient specific model of cardiovascular system using CT and MRI [6141-75]
S. Yamamoto, H. Bartsch, S. Maruyama, S. Yoneyama, S. Wada, T. Yamaguchi, H. Naito
A subdivision-based parametric deformable model for surface extraction and statistical shape modelingof the knee cartilages [6141-76]
J. Fripp, S. Crozier, S. Warfield, S. Ourselin
Optimizing needle placement in treatment planning of radiofrequency ablation [6141-77]
C. Chen, M. Miga, R. Galloway
Automatic surface correspondence methods for a deformed breast [6141-78]
D. Schuler III, J. Ou, S. Barnes, M. Miga
NEURO POSTER SESSION
A pediatric brain structure atlas from T1-weighted MR images [6141-79]
Z. Shan, C. Parra, Q. Ji, R. Ogg, Y. Zhang, F. Laningham, W. Reddick
Flow visualization for qualitative assessment of brain shift [6141-80]
L. Zagorchev, A. Goshtasby, M. Satter
Localization and labeling of rat brain in MR image based on Paxinos-Watson atlas [6141-82]
J. Cao, C. Cai, M. Ding, C. Zhou
Subdural and depth electrode placement in the brain for validation of MEG in partial epilepsy [6141-83]
M. Siadat, K. Elisevich, H. Soltanian-Zadeh, K. Jafari-Khouzani, S. Bowyer
Robust surface registration for brain PET-CT fusion [6141-84]
H. Lee, H. Hong
Registration of laser range image of cortical surface to preoperative brain MR images for image-guidedneurosurgery: preliminary results [6141-85]
B. Tsagaan, K. Abe, K. Iwami, S. Yamamoto, S. Terakawa
Segmentation of brain volume based on 3D region growing by integrating intensity and edge for image-guided surgery [6141-86]
B. Tsagaan, K. Abe, M. Goto, S. Yamamoto, S. Terakawa
Knowledge modeling in image-guided neurosurgery: application in understanding intraoperative brainshift [6141-87]
J. Cohen-Adad, P. Paul, X. Morandi, P. Jannin
REGISTRATION POSTER SESSION
Assessment of radio frequency ablation treatment of hepatic tumors [6141-88]
P. Hemler, E. McCreedy, R. Cheng, B. Wood, M. McAuliffe
Fast 2D-3D marker-based registration of CT and x-ray fluoroscopy images for image-guided surgery[6141-89]
H. Hong, K. Kim, S. Park
Sequential intrinsic and extrinsic geometry calibration in fluoro CT imaging with a mobile C-arm [6141-90]
A. Cheryauka, S. Breham, W. Christensen
Spatio-temporal analysis tool for modeling pulmonary nodules in MR images [6141-91]
L. Shen, H. Huang, J. Ford, C. Lu, L. Gao, W. Zheng, F. Makedon, J. Pearlman
ITK implementation of deformable registration methods for time-varying (4D) imaging data [6141-92]
T. Popa, L. Ibáñez, K. Cleary, K. Wong
A novel 2D-3D registration algorithm for aligning fluoro images with 3D pre-op CT/MR images [6141-93]
H. Sundar, A. Khamene, C. Xu, F. Sauer, C. Davatzikos
ULTRASOUND POSTER SESSION
A novel ultrasound-guided shoulder arthroscopic surgery [6141-94]
K. Tyryshkin, P. Mousavi, M. Beek, T. Chen, D. Pichora, P. Abolmaesumi
Freehand 3D ultrasound calibration using an electromagnetically tracked needle [6141-95]
H. Zhang, F. Banovac, A. White, K. Cleary
Ultrasound self-calibration [6141-96]
E. Boctor, I. Iordachita, G. Fichtinger, G. Hager
VISUALIZATION POSTER SESSION
Embedding VTK and ITK into a visual programming and rapid prototyping platform [6141-97]
M. Koenig, W. Spindler, J. Rexilius, J. Jomier, F. Link, H. Peitgen
Interactive dual-volume rendering visualization with real-time fusion and transfer function enhancement[6141-98]
H. Macready, J. Kim, D. Feng, W. Cai
Volume rendering segmented data using 3D textures: a practical approach for intra-operative visualization[6141-99]
N. Subramanian, R. Mullick, V. Vaidya
Slice cutting and partial exposing techniques for three-dimensional texture-based volume rendering[6141-100]
L. Wu, V. Amin, T. Ryken
A 3D summary display for reporting organ tumors and other pathologies [6141-101]
H. Shen, M. Shao
Graphics hardware based volumetric medical dataset visualization and classification [6141-102]
Q. Zhang, R. Eagleson, T. Peters
High quality GPU rendering with displaced pixel shading [6141-103]
H. Zhang, J. Choi
Volume 6142 Medical Imaging 2006: Physics of Medical Imaging
Chairs/Editors: Michael J. Flynn, Jiang Hsieh
Conference Committee
KEYNOTE SESSION
Low cost digital radiographic imaging systems: the x-ray light valve [6142-3]
J. Rowlands, C. Webster, I. Koprinarov, P. Oakham, K. Schad, T. Szeto, S. Germann
A multi-beam x-ray imaging system based on carbon nanotube field emitters [6142-4]
J. Zhang, G. Yang, Y. Lee, Y. Cheng, B. Gao, Q. Qiu, J. Lu, O. Zhou
MAMMOGRAPHY
Applying the European protocol for the quality control of the physical and technical aspects ofmammography screening threshold contrast visibility assessment to digital systems [6142-108]
R. Van Metter, M. Heath, L. Fletcher-Heath
Comparison of software and human observers in reading images of the CDMAM test object to assessdigital mammography systems [6142-6]
K. Young, J. Cook, J. Oduko, H. Bosmans
Anatomically adaptable automatic exposure control (AEC) for amorphous selenium (a-Se) full fielddigital mammography (FFDM) system [6142-7]
M. Varjonen, P. Strömmer
Preliminary investigation of dose for a dedicated mammotomography system [6142-8]
R. McKinley, M. Tornai
Comparison of polychromatic and monochromatic x-rays for imaging [6142-9]
M. Hoheisel, P. Bernhardt, R. Lawaczeck, H. Pietsch
Optimization of operating conditions in photon-counting multi-slit mammography based on Si-stripdetectors [6142-10]
M. Åslund, B. Cederström, M. Lundqvist, M. Danielsson
TOMOSYNTHESIS
Evaluation of a photon-counting breast tomosynthesis imaging system [6142-11]
A. Maidment, C. Ullberg, K. Lindman, L. Adelöw, J. Egerström, M. Eklund, T. Francke, U. Jordung, T. Kristoffersson, L. Lindqvist, D. Marchal, H. Olla, E. Penton, J. Rantanen, S. Solokov, N. Weber, H. Westerberg
High-speed large angle mammography tomosynthesis system [6142-12]
J. Eberhard, P. Staudinger, J. Smolenski, J. Ding, A. Schmitz, J. McCoy, M. Rumsey, A. Al-Khalidy, W. Ross, C. Landberg, B. Claus, P. Carson, M. Goodsitt, H. Chan, M. Roubidoux, J. Thomas, J. Osland
Quantification for contrast-enhanced digital breast tomosynthesis [6142-13]
A. Carton, J. Li, M. Albert, S. Chen, A. Maidment
Gaussian frequency blending algorithm with matrix inversion tomosynthesis (MITS) and filtered backprojection (FBP) for better digital breast tomosynthesis reconstruction [6142-14]
Y. Chen, J. Lo, J. Baker, J. Dobbins III
Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device [6142-15]
T. Mertelmeier, J. Orman, W. Haerer, M. Dudam
X-RAY CT: CARDIAC
Motion artifacts from an inverse-geometry CT system with multiple detector arrays [6142-16]
S. Mazin, N. Pelc
Design considerations in cardiac CT [6142-17]
H. Bruder, K. Stierstorfer, C. McCullough, R. Raupach, M. Petersilka, M. Grasruck, C. Suess, B. Ohnesorge, T. Flohr
Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT [6142-18]
W. Segars, K. Taguchi, G. Fung, E. Fishman, B. Tsui
Toward time resolved 4D cardiac CT imaging with patient dose reduction: estimating the global heart motion[6142-19]
K. Taguchi, W. Segars, G. Fung, B. Tsui
Optimized time window for cardiac CT reconstruction based on Doppler tissue imaging (DTI) data [6142-20]
R. Guerra, A. Codreanu, Y. Ponvianne, R. Grosjean, J. Felblinger
ECG gated continuous circular cone-beam multi-cycle reconstruction for in-stent coronary arteryimaging: a phantom study [6142-21]
U. van Stevendaal, P. Koken, P. Begemann, R. Koester, G. Adam, M. Grass
OPTICAL AND MR IMAGING
Impact of noise on image reconstruction for diffuse optical tomography [6142-22]
T. Nielsen, T. Köhler
High-resolution multiphoton optical tomography of tissues: an in vitro and in vivo study [6142-23]
I. Riemann, K. Schenke-Layland, A. Ehlers, E. Dimitrow, M. Kaatz, P. Elsner, S. Martin, K. König
Generalized auto-calibrating technique for image reconstruction from sensitivity encoded MRI data [6142-24]
E. Kholmovski, D. Parker
Reducing temporal fluctuations in MRI with the multichannel method SENSE [6142-25]
S. Moeller, P. Van de Moortele, U. Goerke, K. U urbil
Description of statistical theory of magnetic resonance imaging (MRI) [6142-26]
T. Lei
X-RAY IMAGING DETECTORS I
Performance evaluation of dual-crystal APD-based detector modules for positron emission tomography[6142-27]
C. Pepin, P. Bérard, J. Cadorette, M. Tétrault, J. Leroux, J. Michaud, S. Robert, H. Dautet, M. Davies, R. Fontaine, R. Lecomte
High voltage protection in active matrix flat-panel imagers [6142-28]
J. Lehnert, W. Zhao
Low-noise pixel architecture for advanced diagnostic medical x-ray imaging applications [6142-29]
M. Izadi, K. Karim, A. Nathan, J. Rowlands
A new 2D-tiled detector for multislice CT [6142-30]
R. Luhta, M. Chappo, B. Harwood, R. Mattson, D. Salk, C. Vrettos
Novel CT detector based on an inorganic scintillator working in photon-counting mode [6142-31]
P. Bérard, J. Riendeau, C. Pepin, D. Rouleau, J. Cadorette, R. Fontaine, R. Lecomte
Three-dimensional columnar CsI model for x-ray imaging system simulations using MANTIS: validatingfor noise, blur, and light output [6142-32]
A. Badano, I. Kyprianou, J. Sempau
X-RAY CT: SYSTEMS
Evaluation of noise and resolution properties of penalized-likelihood CT sinogram smoothing andrestoration algorithms [6142-33]
P. La Rivière, P. Vargas
Comparison of three sinogram restoration methods [6142-34]
P. Forthmann, T. Köhler, M. Defrise, P. La Rivière
Investigation of image lag in a high-speed flat panel detector-based cone beam CT imaging system [6142-35]
Y. Zhang, R. Ning, D. Conover
Design and development of C-arm based cone-beam CT for image-guided interventions: initial results[6142-36]
G. Chen, J. Zambelli, B. Nett, M. Supanich, C. Riddell, B. Belanger, C. Mistretta
A novel cone beam breast CT scanner: preliminary system evaluation [6142-37]
R. Ning, D. Conover, Y. Yu, Y. Zhang, W. Cai, X. Lu, R. Betancourt-Benitez
Guidance for cone-beam CT design: tradeoff between view sampling rate and completeness ofscanning trajectories [6142-38]
G. Chen, J. Siewerdsen, S. Leng, D. Moseley, B. Nett, J. Hsieh, D. Jaffray, C. Mistretta
INNOVATIVE IMAGING
Application of x-ray computed tomography based on the refraction contrast to biomedicine [6142-39]
E. Hashimoto, A. Maksimenko, H. Sugiyama, K. Hyodo, D. Shimao, T. Yuasa, Y. Nishino, T. Ishikawa, K. Mori, Y. Arai, K. Hirano, M. Ando
3D cryo-section/imaging of blood vessel lesions for validation of MRI data [6142-40]
O. Salvado, D. Roy, M. Heinzel, E. McKinley, D. Wilson
Performance of different reflectance and diffuse optical imaging tomographic approaches in fluorescencemolecular imaging of small animals [6142-41]
J. Dinten, P. Petié, A. da Silva, J. Boutet, A. Koenig, L. Hervé, M. Berger, A. Laidevant, P. Rizo
Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner [6142-42]
L. Du, T. Lee, D. Holdsworth
Rotating slat collimator design for high-energy near-field imaging [6142-43]
A. Sharma, C. Floyd, B. Harrawood, G. Tourassi, A. Kapadia, J. Bender, J. Lo, C. Howell
X-RAY IMAGING
Regional exposure management with spatial x-ray gating [6142-44]
D. Yatsenko, R. Anderton, K. Sikorski, R. Kirby
Applying a proposed definition for receptor dose to digital projection images [6142-45]
R. Van Metter, J. Yorkston
The impact of angular separation on the performance of biplane correlation imaging for lung noduledetection [6142-46]
N. Nasab, E. Samei
Evaluation of a physical based approach of scattered radiation correction in cone beam CT with ananthropomorphic thorax phantom [6142-47]
J. Rinkel, L. Gerfault, F. Estève, J. Dinten
Scatter correction for cone-beam computed tomography using simulated object models [6142-48]
M. Bertram, J. Wiegert, G. Rose
Development of next generation digital flat panel catheterization system: design principles andvalidation methodology [6142-49]
B. Belanger, F. Betraoui, P. Dhawale, P. Gopinath, P. Tegzes, B. Vagvolgyi
DUAL ENERGY X-RAY IMAGING
High-performance dual-energy imaging with a flat-panel detector: imaging physics from blackboard tobenchtop to bedside [6142-50]
J. Siewerdsen, N. Shkumat, A. Dhanantwari, D. Williams, S. Richard, M. Daly, N. Paul, D. Moseley, D. Jaffray, J. Yorkston, R. Van Metter
The impact of cardiac gating on the detection of coronary calcifications in dual-energy chest radiography:a phantom study [6142-51]
J. Sabol, R. Liu, R. Saunders, J. Markley, N. Moreno, J. Seamans, S. Wiese, K. Jabri, R. Gilkeson
Accuracy and precision of dual energy CT imaging for the quantification of tissue fat content [6142-52]
D. Walter, E. Tkaczyk, X. Wu
Dual-energy imaging using a photon counting detector with electronic spectrum-splitting [6142-53]
H. Bornefalk, M. Lundqvist
Multispectral single-scan lung imaging system: initial feasibility [6142-54]
G. Besson, K. Crocker
COMPUTATIONAL SIMULATION
Simulated and experimental technique optimization of dual-energy radiography: abdominal imagingapplications [6142-55]
J. Sabol, S. Wheeldon, K. Jabri
Light transport in trabecular bone: Monte Carlo simulation based on 3D triangle meshes [6142-56]
E. Margallo-Balbás, P. French, P. Wieringa
Optimal spectra for indirect detector breast tomosynthesis [6142-57]
S. Glick, X. Gong
Development of a computer-generated model for the coronary arterial tree based on multislice CT andmorphometric data [6142-58]
G. Fung, W. Segars, K. Taguchi, E. Fishman, B. Tsui
Monte Carlo simulation of x-ray scatter based on patient model from digital breast tomosynthesis
B. Liu, T. Wu, R. Moore, D. Kopans
Breast cancer diagnosis using neutron stimulated emission computed tomography: dose and countrequirements [6142-60]
C. Floyd Jr., J. Bender, B. Harrawood, A. Sharma, A. Kapadia, G. Tourassi, J. Lo, C. Howell
X-RAY IMAGING DETECTORS II
Theoretical investigation of very high-quantum-efficiency segmented crystalline detectors for low-contrast visualization in megavoltage cone-beam CT [6142-61]
Y. Wang, L. Antonuk, Y. El-Mohri, A. Sawant, Q. Zhao, H. Du, Y. Li
CMOS cassette for digital upgrade of film-based mammography systems [6142-62]
M. Baysal, E. Toker
New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCTmammography and fluoroscopy [6142-63]
S. Rudin, A. Kuhls, G. Yadava, G. Josan, Y. Wu, R. Chityala, H. Rangwala, N. Ionita, K. Hoffmann, D. Bednarek
Effect of ghosting on the modulation transfer function of amorphous selenium based flat paneldetectors [6142-64]
L. Chowdhury, O. Tousignant, G. DeCrescenzo, P. Gauthier, J. Leboeuf, J. Rowlands
Single-photon spatial and energy resolution enhancement of a columnar CsI(Tl)/EMCCD gamma-camerausing maximum-likelihood estimation [6142-65]
B. Miller, H. Barber, H. Barrett, I. Shestakova, B. Singh, V. Nagarkar
CT AND DR PERFORMANCE ASSESSMENT
A practical method for measuring the H matrix of digital x-ray and cone beam CT imaging systems [6142-66]
I. Kyprianou, A. Badano, B. Gallas, S. Park, K. Myers
Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography[6142-67]
D. Crotty, R. McKinley, M. Tornai
Preliminary validation of a new methodology for estimating dose reduction protocols in neonatal chestcomputed radiographs [6142-68]
S. Don, B. Whiting, C. Hildebolt, W. Sehnert, J. Ellinwood, K. Töpfer, P. Masoumzadeh, R. Kraus, K. Kronemer, T. Herman, W. McAlister
A method to measure the temporal MTF to determine the DQE of fluoroscopy systems [6142-69]
S. Friedman, I. Cunningham
A novel method to characterize the MTF in 3D for computed mammotomography [6142-70]
P. Madhav, R. McKinley, E. Samei, J. Bowsher, M. Tornai
Measurement of the spatial resolution of a clinical volumetric computed tomography scanner using asphere phantom [6142-71]
M. Thornton, M. Flynn
CONE BEAM RECONSTRUCTION
Extension of the reconstruction field-of-view using sinogram decomposition [6142-72]
A. Zamyatin, M. Silver, S. Nakanishi
Suppression of motion-induced streak artifacts along chords in fan-beam BPF-reconstructions ofmotion-contaminated projection data [6142-73]
M. King, D. Xia, L. Yu, X. Pan, M. Giger
Reconstructions from parallel- and fan-beam data with truncations [6142-74]
D. Xia, Y. Zou, X. Pan
Iterative reconstruction of a region of interest for transmission tomography [6142-75]
A. Ziegler, T. Nielsen, M. Grass
An iterative algorithm for soft tissue reconstruction from truncated flat panel projections [6142-76]
D. Langan, B. Claus, P. Edic, R. Vaillant, B. De Man, S. Basu, M. Iatrou
CT IMAGE RECONSTRUCTION
Conjugate backprojection approach for cone beam artifact reduction [6142-77]
J. Hsieh, X. Tang
Cone-beam local tomography image reconstruction on chords [6142-78]
M. Anastasio, E. Sidky, Y. Zou, X. Pan
3D-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction at low-helicalpitches to improve noise characteristics and dose efficiency [6142-79]
X. Tang, J. Hsieh, R. Nilsen
ROI-image reconstruction for a circle-arc trajectory [6142-80]
Y. Zou, D. Xia, X. Pan
Accurate image reconstruction in CT from projection data taken at few-views [6142-81]
E. Sidky, C. Kao, X. Pan
A new reconstruction algorithm for Radon data [6142-82]
Y. Xu, O. Tischenko, C. Hoeschen
X-RAY CT POSTER SESSION
Data pre-processing for quantification in tomography and radiography with a digital flat panel detector[6142-83]
J. Rinkel, L. Gerfault, F. Estève, J. Dinten
Flat panel detector-based cone beam CT for dynamic imaging: system evaluation [6142-84]
R. Ning, D. Conover, Y. Yu, Y. Zhang, W. Cai, D. Yang, X. Lu
Experimental comparison of cone beam CT (CBCT) reconstruction and multiview reconstruction (MVR)for microangiography (MA) detector system [6142-85]
V. Patel, A. Kuhls, P. Noël, A. Walczak, C. Ionita, R. Chityala, R. Tranquebar, H. Rangwala, S. Kasodekar, K. Hoffmann, D. Bednarek, S. Rudin
Geometry calibration phantom design for 3D imaging [6142-86]
B. Claus
Impact of CT detector pixel-to-pixel crosstalk on image quality [6142-87]
K. Engel, L. Spies, G. Vogtmeier, R. Luhta
Image quality improvement and exposure dose reduction with the combined use of X-ray modulationand Boost3D [6142-88]
M. Kazama, S. Tsukagoshi, M. Okumura
Windmill artifacts analysis in MSCT [6142-89]
O. Amir, I. Sabo-Napadensky
Amplitude correlated 4-dimensional cone beam CT [6142-90]
J. Lu, X. Zhu, P. Munro, P. Chi, R. Mohan, T. Pan
Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner [6142-91]
M. Grasruck, R. Gupta, B. Reichardt, Ch. Suess, B. Schmidt, K. Stierstorfer, S. Popescu, T. Brady, T. Flohr
Comparison measurements of DQE for two flat panel detectors: fluoroscopic detector vs. cone beamCT detector [6142-92]
R. Betancourt Benítez, R. Ning, D. Conover
A new scanning device in CT with dose reduction potential [6142-93]
O. Tischenko, Y. Xu, C. Hoeschen
X-ray tube voltage and image quality in adult and pediatric CT [6142-94]
W. Huda, K. Ogden, E. Scalzetti, R. Lavallee, E. Samei
DUAL ENERGY X-RAY IMAGING POSTER SESSION
Dual-energy contrast-enhanced digital mammography (DE-CEDM): optimization on digital subtractionwith practical x-ray low/high-energy spectra [6142-95]
B. Chen, Z. Jing, A. Smith, S. Parikh, Y. Parisky
Dual-energy imaging using a digital scanned multi-slit system for mammography: evaluation of adifferential beam filtering technique [6142-96]
H. Bornefalk, M. Hemmendorff, T. Hjärn
Nonlinear dual-spectral image fusion for improving cone-beam-CT-based breast cancer diagnosis [6142-97]
Z. Chen, R. Ning, D. Conover, K. Willison
An iteration algorithm in dual-energy x-ray imaging based on polychromatic physics model [6142-99]
S. Tang, X. Mou, T. Luo
A computation method of dual-energy x-ray imaging [6142-100]
X. Mou, S. Tang, W. Hong
X-RAY IMAGING DETECTOR POSTER SESSION
The line-noise-reduction for low dose x-ray fluoroscopy with the flat panel detector [6142-101]
T. Nakamura, S. Ikeda, K. Suzuki, S. Takenouchi
Light induced degradation in amorphous silicon photodiodes and implication for diagnostic medicalimaging application [6142-102]
I. Khodami, M. Adachi, M. Malhotra, F. Taghibakhsh, J. Rowlands, K. Karim, K. Kavanagh
Temperature coefficients and noise performance and studies for the back-illuminated arrays formedical imaging applications [6142-103]
A. Goushcha, B. Tabbert, I. Goushcha
Novel x-ray image sensor using CsBr:Eu phosphor for computed radiography [6142-104]
H. Nanto, Y. Takei, A. Nishimura, Y. Nakano, T. Shouji, T. Yanagita, S. Kasai
Transparent BaCl2:Eu2+
glass-ceramic scintillator [6142-105]
G. Chen, J. Johnson, S. Schweizer, J. Woodford, P. Newman, D. MacFarlane
Energy-dependent scintillation intensity of fluorozirconate-based glass-ceramic x-ray detectors [6142-106]
S. Schweizer, B. Henke, S. Köneke, J. Johnson, G. Chen, J. Woodford
Quantitative evaluation of mercuric iodide thick film for x-ray imaging device [6142-107]
K. Kim, S. Kang, J. Park, S. Cho, B. Cha, J. Shin, S. Nam, J. Kim
MAMMOGRAPHY AND RADIOGRAPHY POSTER SESSION
Investigation of diagnostic and image quality attributes: comparison of screen-film to CR mammography[6142-5]
L. Fletcher-Heath, A. Richards, S. Ryan-Kron
Comparison of a-Se direct-conversion and CsI(Tl) indirect-conversion flat-panel digital detectors:a clinical assessment of image quality for general radiography applications [6142-109]
L. Barski, X. Wang, J. Wandtke, D. Waldman, D. Davis, D. Foos, M. Dupin, W. Huang, J. Yorkston
Novel features of the x-ray scatter profile that are not modeled by convolution of the primary [6142-110]
J. Tkaczyk, Y. Trousset, D. Walter, Y. Du, R. Thompson, D. Harrison
Effects of radiation dose level on calcification visibility in cone beam breast CT: a preliminary study[6142-111]
C. Lai, C. Shaw, M. Altunbas, Y. Meng, L. Chen, S. Tu, T. Wang, X. Liu, W. Yang, G. Whitman
An accurate scatter measurement and correction technique for cone beam breast CT imaging usingscanning sampled measurement (SSM)technique [6142-112]
X. Liu, C. Shaw, T. Wang, L. Chen, M. Altunbas, S. Kappadath
Scattered radiation in flat-detector based cone-beam CT: analysis of voxelized patient simulations [6142-113]
J. Wiegert, M. Bertram
Effects of scattered radiation and beam quality on low contrast performance in cone beam breast CT[6142-114]
M. Altunbas, C. Shaw, L. Chen, T. Wang, S. Tu
Investigation of emission contamination in the transmission image of a dual modality computedmammotomography system [6142-115]
D. Crotty, C. Brzymialkewicz, R. McKinley, M. Tornai
Comparison of scatter correction methods for CBCT [6142-116]
R. Suri, G. Virshup, L. Zurkirchen, W. Kaissl
Calculation of images from an anthropomorphic chest phantom using Monte Carlo methods [6142-117]
G. Ullman, A. Malusek, M. Sandborg, D. Dance, G. Alm Carlsson
A Monte Carlo investigation on the impact of scattered radiation on mammographic resolution andnoise [6142-118]
R. Saunders, E. Samei
A comparison of the performance of new screen-film and digital mammography systems [6142-119]
P. Monnin, D. Gutierrez, C. Castella, D. Lepori, F. Verdun
Dynamic platform for moving organ imaging [6142-120]
R. Grosjean, R. Guerra, C. Lorentz, C. Pasquier, P. Vuissoz, M. Claudon, J. Felblinger
Anode heel affect in thoracic radiology: a visual grading analysis [6142-121]
T. Mearon, P. Brennan
Scatter correction using beam stop array algorithm for cone-beam CT breast imaging [6142-122]
W. Cai, R. Ning, D. Conover
Response of a CsI/amorphous-Si flat panel detector as function of incident x-ray angle [6142-123]
J. Tkaczyk, B. Claus, D. Gonzalez Trotter, J. Eberhard
Dosimetric and image quality assessment of different acquisition protocols of a novel 64-slice CTscanner [6142-124]
C. Vite, M. Mangini, S. Strocchi, R. Novario, F. Tanzi, G. Carrafiello, L. Conte, C. Fugazzola
Novel NPS measurement method for medical liquid crystal display using periodic componentssubtraction technique [6142-125]
K. Ichikawa, Y. Kodera, A. Horii
A method of accuracy evaluation of line spread function (LSF) and point spread function (PSF) measuredin computed tomography [6142-126]
S. Wada, M. Ohkubo, T. Matsumoto, K. Nishizawa
Substrate effect on indirect digital radiography system performance [6142-127]
A. Lubinsky, K. Yip, D. Trauernicht, J. Yorkston
A robust x-ray tube spectra measuring method by attenuation data [6142-129]
Y. Yang, X. Mou, X. Chen
OPTICAL, MR, AND MICRO IMAGING POSTER SESSION
Choosing the right resolution for vessel visualization in MR angiography [6142-130]
P. Vemuri, E. Kholmovski, D. Parker
New microangiography system development providing improved small vessel imaging, increasedcontrast-to-noise ratios, and multiview 3D reconstructions [6142-131]
A. Kuhls, V. Patel, C. Ionita, P. Noël, A. Walczak, H. Rangwala, K. Hoffmann, S. Rudin
Stationary x-ray source for tomographic medical imaging [6142-132]
P. Schwoebel, J. Boone
Novel SNR determination method in parallel MRI [6142-133]
T. Miyati, H. Imai, A. Ogura, T. Doi, T. Tsuchihashi, Y. Machida
Fast parallel MRI reconstruction using B-spline approximation (PROBER) [6142-134]
J. Petr, J. Kybic, V. Hlavá , S. Müller, M. Bock
First attempt of the medical application of the refraction-based computed tomography [6142-135]
A. Maksimenko, E. Hashimoto, M. Ando, H. Sugiyama, T. Yuasa
Photo-bleaching compensation for autofocus algorithms in fluorescence microscope applications [6142-137]
P. Soda, G. Iannello
MR image reconstruction using the GPU [6142-138]
T. Schiwietz, T. Chang, P. Speier, R. Westermann
Spectral imaging of skin: experimental observations and analyses [6142-140]
J. Kerekes, N. Subramanian, K. Kearney, N. Schad
Fat/water separation in a single MRI image with arbitrary phase shift [6142-142]
M. Tisdall, M. Atkins
Spectral imaging of near-surface oxygen saturation [6142-143]
N. Subramanian, J. Kerekes, K. Kearney, N. Schad
Effects of collimator dependency and correction methods on I-123 SPECT images using x-ray-basedattenuation map [6142-144]
Y. Yang, J. Chen, C. Chang, C. Cheng, W. Huang
Discrete tomography from micro-CT data: application to the mouse trabecular bone structure [6142-145]
K. Batenburg, J. Sijbers
Development of a K-edge micro CT for the study of tumor angiogenesis in small animals [6142-146]
G. Baldazzi, D. Bollini, M. Gambaccini, R. Golfieri, P. Lollini, A. Margotti, S. Masetti, G. Nicoletti, G. Pancaldi, L. Roma, P. Rossi, M. Zuffa
Improved diagnostics using polarization imaging and artificial neural networks [6142-149]
U. Klimach, H. Zhao, Q. Chen, Y. Zou, Y. Wang, J. Xuan
Comparison of two detector systems for cone beam CT small animal imaging: a preliminary study[6142-150]
Y. Meng, C. Shaw, X. Liu, M. Altunbas, T. Wang, L. Chen, S. Tu, S. Kappadath, C. Lai
IMAGE RECONSTRUCTION POSTER SESSION
Maximum likelihood reconstruction of circular cone-beam CT data [6142-151]
A. Ziegler, T. Köhler
Penalized weighted least-squares approach for low-dose x-ray computed tomography [6142-152]
J. Wang, T. Li, H. Lu, Z. Liang
An extended half-scan Feldkamp-type CT reconstruction [6142-153]
H. Liang, C. Zhang, M. Yan
Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) onbreast phantom data [6142-154]
Y. Zhang, H. Chan, B. Sahiner, J. Wei, M. Goodsitt, L. Hadjiiski, J. Ge, C. Zhou
An inversion method for the exponential radon transform based on the harmonic analysis of theEuclidean motion group [6142-155]
C. Yarman, B. Yazıcı
Elliptical extrapolation of truncated 2D CT projections using Helgason-Ludwig consistency conditions[6142-156]
G. Van Gompel, M. Defrise, D. Van Dyck
An inversion method for the cone-beam transform [6142-157]
C. Yarman, B. Yazıcı
A new approach of 3D SPECT reconstruction for near-field coded aperture imaging [6142-158]
B. Hong, Z. Mu, Y. Liu
Noise reduction for low-dose helical CT by 3D penalized weighted least-squares sinogram smoothing[6142-159]
J. Wang, T. Li, H. Lu, Z. Liang
Quarantine MAP reconstruction of PET/CT data using dual priors [6142-160]
C. Chan, S. Meikle, R. Fulton, T. Cai, D. Feng
Computer simulation of FDK reconstruction with the in-line holographic projection data [6142-161]
W. Cai, R. Ning, D. Yang
Reconstruction implementation based on a flat panel detector cone beam breast CT [6142-162]
D. Yang, R. Ning, D. Conover, Y. Yu
Interpolation method for the Mojette transform [6142-163]
M. Servières, N. Normand, J. Guédon
Image reconstruction in cone-beam CT with a spherical detector using the BPF algorithm [6142-164]
N. Zuo, Y. Zou, T. Jiang, X. Pan
Effect of random coincidences for quantitative cardiac PET studies using 3D oxygen-15 water scans[6142-165]
Y. Bouchareb, K. Thielemans, T. Spinks, O. Rimoldi, P. Camici
Acceleration of fluoro-CT reconstruction for a mobile C-arm on GPU and FPGA hardware: a simulationstudy [6142-166]
X. Xue, A. Cheryauka, D. Tubbs
Comparison of full-scan and half-scan for cone beam breast CT imaging [6142-167]
L. Chen, C. Shaw, C. Lai, M. Altunbas, T. Wang, S. Tu, X. Liu
A backprojection filtered image reconstruction algorithm for circular cone-beam CT [6142-168]
L. Li, Z. Chen, L. Zhang, Y. Xing, K. Kang
Implementation of strip-area system model for fan-beam collimator SPECT reconstruction [6142-169]
H. Ye, A. Krol, D. Feiglin, E. Lipson, W. Lee, I. Coman
Accelerating 3D cone beam T-FDK algorithm on commodity PC graphics hardware [6142-170]
Z. Dai, Z. Chen, Y. Xing, L. Zhang
Radial intensity projection for lumen: application to CT angiographic imaging [6142-172]
H. Kokubun, O. Miyazaki, H. Hayashi
Evaluation of an algorithm for simultaneous reconstruction of activity and attenuation in 3D PET [6142-173]
J. Soto, S. Furuie
Image reconstruction from discrete Chebyshev moments via formation of lookup tables [6142-174]
B. Bayraktar, T. Bernas, J. Robinson, B. Rajwa
An approximate cone beam reconstruction algorithm for gantry-tilted CT [6142-175]
M. Yan, C. Zhang, H. Liang
Implementing an iterative reconstruction algorithm for digital breast tomosynthesis on graphics processinghardware [6142-176]
I. Goddard, T. Wu, S. Thieret, A. Berman, H. Bartsch
A correction method for unfunctional cell distortion using orthogonal polynomials [6142-177]
S. Tang, X. Mou, H. Yan
Implementation of a spiral CT backprojection algorithm on the cell broadband engine processor [6142-178]
O. Bockenbach, I. Goddard, S. Schuberth, M. Seebass
Cone-beam CT reconstruction using a nonlinear weighted filtered backprojection from half-scan data[6142-179]
T. Gomi, K. Koshida, T. Miyati
COMPUTATIONAL SIMULATION POSTER SESSION
The effect of detector resolution for quantitative analysis of neutron stimulated emission computedtomography [6142-180]
J. Bender, C. Floyd, B. Harrawood, A. Kapadia, A. Sharma, J. Jesneck
Image quality simulation and verification of x-ray volume imaging systems [6142-181]
H. Kroon, N. Schoumans, R. Snoeren
Correction of inter-crystal scatter effect in iterative image reconstruction of the jPET-D4 [6142-183]
C. Lam, N. Hagiwara, T. Obi, M. Yamaguchi, T. Yamaya, H. Murayama
A novel model of the geometric and detector response for limited angular sampling pinhole SPECT[6142-185]
C. Wietholt, I. Hsiao, A. Clough, C. Chen
Scatter correction for kilovoltage cone-beam computed tomography (CBCT) images using Monte Carlosimulations [6142-186]
G. Jarry, S. Graham, D. Jaffray, D. Moseley, F. Verhaegen
Discrete and continuous description of a three-dimensional scene for quality control of radiotherapytreatment planning systems [6142-187]
E. Denis, J. Guédon, S. Beaumont, N. Normand
Modeling of realistic raw data for image reconstruction: quantifying scattering noise in different CTgeometries [6142-188]
H. Schlattl, O. Tischenko, C. Hoeschen
Monte Carlo simulation for the hybrid detector design [6142-189]
S. Kim, J. Park, S. Kang, B. Cha, S. Cho, E. Jeong, S. Nam, H. Lee, H. Choi
Characterization of point spread function in linear digital tomosynthesis: a simulation study [6142-190]
G. Avinash, K. Israni, B. Li
Noise power spectrum analysis for several digital breast tomosynthesis reconstruction algorithms [6142-191]
Y. Chen, J. Lo, J. Dobbins III
Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom [6142-192]
L. Zhou, J. Oldan, P. Fisher, G. Gindi
Selective photon counter for digital x-ray mammography tomosynthesis [6142-193]
A. Goldan, K. Karim, J. Rowlands
Preliminary assessment of the temporal subtraction of tomosynthesis images for improved detectionof pulmonary nodules [6142-194]
C. Li, J. Dobbins III
Measurement of slice thickness and in-plane resolution on radiographic tomosynthesis system usingmodulation transfer function (MTF) [6142-195]
B. Li, R. Saunders, R. Uppaluri
Optimal acquisition techniques for digital breast tomosynthesis screening [6142-196]
T. Wu, B. Liu, R. Moore, D. Kopans
Volume 6143 Medical Imaging 2006: Physiology, Function, and Structure from Medical Images
Chairs/Editors: Armando Manduca, Amir A. Amini
Conference Committee
Introduction
SMALL ANIMAL IMAGING
Structure and function relationship of Zebrafish embryonic heart from confocal microscopy images [6143-1]
A. Moghaddam, A. Forouhar, M. Liebling, H. Tsai, M. Gharib
Quantification of adipose tissue in a rodent model of obesity [6143-2]
D. Johnson, C. Flask, D. Wan, P. Ernsberger, D. Wilson
Precise imaging of small animals using a dual-head microPET scanner [6143-3]
C. Kao, E. Sidky, Y. Dong, X. Pan
Optimization of retrospective respiratory-gated high speed micro-CT for free-breathing mice [6143-4]
N. Ford, S. Detombe, A. Wheatley, D. Holdsworth, M. Drangova
In vivo micro-CT imaging of the murine lung via a computer controlled intermittent iso-pressure breathhold (IIBH) technique [6143-5]
E. Namati, D. Chon, J. Thiesse, G. McLennan, J. Sieren, A. Ross, E. Hoffman
CARDIOVASCULAR IMAGING
Electrocardiographic imaging (ECGI): a new noninvasive imaging modality for cardiac electrophysiologyand arrhythmia [6143-6]
Y. Rudy
Analysis of four-dimensional cardiac ventricular magnetic resonance images using statistical models ofventricular shape and cardiac motion [6143-7]
H. Zhang, N. Walker, S. Mitchell, M. Thomas, A. Wahle, T. Scholz, M. Sonka
Quantitative analysis of vascular dimension and plaque composition in coronary multidetectorcomputed tomography images [6143-8]
M. Olszewski, A. Wahle, M. Vembar, L. Ciancibello, A. Kerner, R. Beyar, E. Ghersin, K. Subramanyan, M. Sonka
Using ChromaFlo intra-vascular ultrasound (IVUS) to analyze adventitial vasa vasorum distribution:considerations and recommendations [6143-9]
A. Redwood, D. Holmes III, R. Robb
VESSEL IMAGING AND DYNAMICS
Quantitative evaluation of carotid arterial plaque surface irregularity [6143-10]
J. Robinson, L. Brevetti, P. Yim
Quantification of carotid vessel atherosclerosis [6143-11]
B. Chiu, M. Egger, J. Spence, G. Parraga, A. Fenster
Pulsatile pressure measurements via harmonics-based orthogonal projection of noisy pressuregradients [6143-12]
Y. Wang, A. Moghaddam, G. Behrens, N. Fatouraee, J. Cebral, E. Choi, A. Amini
Patient-specific models of wall stress in abdominal aortic aneurysm: a comparison between MR and CT[6143-13]
S. de Putter, M. Breeuwer, F. van de Vosse, U. Kose, F. Gerritsen
Effects of parent vessel geometry on intraaneurysmal flow patterns [6143-14]
M. Castro, C. Putman, J. Cebral
Effects of segmentation on patient-specific numerical simulation of cerebral aneurysm hemodynamics[6143-15]
P. Venugopal, H. Schmitt, G. Duckwiler, D. Valentino
CEREBRAL HEMODYNAMICS
Imaging and CFD in the analysis of vascular disease progression [6143-16]
D. Saloner, G. Acevedo-Bolton, V. Rayz, M. Wintermark, A. Martin, B. Dispensa, W. Young, M. Lawton, J. Rapp, L. Jou
Reproducibility of brain hemodynamic simulations: an inter-solver comparison [6143-17]
X. He, P. Venugopal, J. Cebral, H. Schmitt, D. Valentino
A study of the hemodynamics of anterior communicating artery aneurysms [6143-18]
J. Cebral, M. Castro, C. Putman
Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digitalsubtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses [6143-19]
Y. Hoi, C. Ionita, R. Tranquebar, K. Hoffmann, S. Woodward, D. Taulbee, H. Meng, S. Rudin
Towards patient-specific modeling I: hemodynamics in a growing aneurysm [6143-20]
C. Figueroa, S. Baek, I. Vignon-Clementel, J. Humphrey, C. Taylor
Dynamic pressure at sites of virtually removed paraclinoid aneurysms: a computational fluid dynamics study[6143-21]
C. Karmonik, A. Mantha, C. Strother, G. Benndorf, R. Metcalfe
LUNG IMAGING
Effect of mixing scanner types and reconstruction kernels on the characterization of lung parenchymalpathologies: emphysema, interstitial pulmonary fibrosis and normal non-smokers [6143-22]
Y. Xu, E. van Beek, G. McLennan, J. Guo, M. Sonka, E. Hoffman
A novel multipurpose tree and path matching algorithm with application to airway trees [6143-23]
J. Kaftan, A. Kiraly, D. Naidich, C. Novak
Point based methods for automatic bronchial tree matching and labeling [6143-24]
T. Bülow, C. Lorenz, R. Wiemker, J. Honko
Quantification of tumor mobility during the breathing cycle using 3D dynamic MRI [6143-25]
M. Schoebinger, C. Plathow, I. Wolf, H. Kauczor, H. Meinzer
Automated airway evaluation system for multi-slice computed tomography using airway lumendiameter, airway wall thickness and broncho-arterial ratio [6143-26]
B. Odry, A. Kiraly, C. Novak, D. Naidich, J. Lerallut
MRI ANALYSIS
Automatic three-dimensional segmentation of MR images applied to the rat uterus [6143-27]
A. Akselrod-Ballin, E. Eyal, M. Galun, E. Furman-Haran, J. Gomori, R. Basri, H. Degani, A. Brandt
Semi-automatic segmentation and quantification of 3D spinal cord data [6143-28]
R. Van Uitert, I. Bitter, J. Butman
Quantification of diffusion-weighted images (DWI) and apparent diffusion coefficient maps (ADC) in thedetection of acute stroke [6143-29]
P. Tulipano, W. Millar, C. Imielinska, X. Liu, J. Rosiene, A. D'Ambrosio
Quantitative analysis of multiple sclerosis: a feasibility study [6143-30]
L. Li, X. Li, X. Wei, D. Sturm, H. Lu, Z. Liang
A methodology to study multiple sclerosis (MS) based on distributions of standardized intensities insegmented tissue regions [6143-31]
T. Lei, J. Udupa, D. Odhner, S. Mishra, G. Wu, E. Schwartz, G. Ying, T. Iwanaga, L. Desiderio, L. Balcer
Micro-MRI-based image acquisition and processing system for assessing the response to therapeuticintervention [6143-32]
B. Vasili , G. Ladinsky, P. Saha, F. Wehrli
MECHANICAL PROPERTIES
Functional microimaging: an integrated approach for advanced bone biomechanics and failure analysis[6143-33]
R. Voide, G. van Lenthe, P. Schneider, P. Thurner, P. Wyss, U. Sennhauser, M. Stampanoni, M. Stauber, J. Snedeker, R. Müller
MR elastographic methods for the evaluation of plantar fat pads: preliminary comparison of the shearmodulus for shearing deformation and compressive deformation in normal subjects [6143-35]
J. Weaver, T. Miller, P. Perrinez, M. Doyley, H. Wang, Y. Cheung, J. Wrobel, R. Comi, F. Kennedy, K. Paulsen
Imaging mechanical properties of hepatic tissue by magnetic resonance elastography [6143-34]
M. Yin, O. Rouviere, L. Burgart, J. Fidler, A. Manduca, R. Ehman
Application of multi-resolution modality independent elastography for detection of multiple anomalousobjects [6143-36]
J. Ou, S. Barnes, M. Miga
Biomechanical registration of prostate images using statistical shape models [6143-37]
P. Courtis, A. Samani
A multi-organ biomechanical model to analyze prostate deformation due to large deformation of the rectum[6143-38]
K. Brock, C. Ménard, J. Hensel, D. Jaffray
VIRTUAL ENDOSCOPY I: VIRTUAL BRONCHOSCOPY AND RELATED METHODS
Real-time CT-video registration for continuous endoscopic guidance [6143-39]
S. Merritt, L. Rai, W. Higgins
Branch identification method for CT-guided bronchoscopy based on eigenspace image matchingbetween real and virtual bronchoscopic images [6143-40]
R. Shinohara, K. Mori, D. Deguchi, T. Kitasaka, Y. Suenaga, H. Takabatake, M. Mori, H. Natori
Synchronous navigation for CT colonography [6143-41]
A. Huang, R. Summers, D. Roy
Virtual cardioscopy: interactive endocardial visualization to guide RF cardiac ablation [6143-42]
D. Holmes III, M. Rettmann, B. Cameron, J. Camp, R. Robb
Fast and accurate tract unfolding based on stable volumetric image deformation [6143-43]
T. Truong, T. Kitasaka, K. Mori, Y. Suenaga
VIRTUAL ENDOSCOPY II: POLYP DETECTION AND ANALYSIS FOR CT COLONOGRAPHY
Effects of filtering on colorectal polyp detection in ultra low dose CT [6143-44]
G. Schoonenberg, A. de Vries, S. Grigorescu, J. Peters, A. Vilanova, R. Truyen, J. Stoker, F. Gerritsen
Automatic procedure to distinguish colonic polyps located on fold vs. not on fold [6143-45]
M. Franaszek, R. Summers, P. Pickhardt, J. Choi
Performance tuning of candidate determination methods for computer aided detection of colon polyps[6143-46]
I. Bitter, M. Kelsey, R. Summers
Quantitative assessment of colon distention for polyp detection in CT virtual colonoscopy [6143-47]
R. Van Uitert, I. Bitter, R. Summers, J. Choi, P. Pickhardt
A method for generating virtual unfolded view of colon using spring model [6143-48]
M. Oda, Y. Hayashi, T. Kitasaka, K. Mori, Y. Suenaga
Geometric modeling, functional parameter calculation, and visualization of the in-vivo distended rectal wallw[6143-49]
C. Haider, A. Manduca, J. Camp, J. Fletcher, R. Robb, A. Bharucha
OPTICAL IMAGING
Imaging system for creating 3D block-face cryo-images of whole mice [6143-50]
D. Roy, M. Breen, O. Salvado, M. Heinzel, E. McKinley, D. Wilson
Evaluating dynamic contrast-enhanced and photoacoustic CT to assess intra-tumor heterogeneity inxenograft mouse models [6143-51]
K. Stantz, B. Liu, M. Cao, D. Reinecke, M. Dzemidzic, Y. Liang, R. Kruger
3D in vivo imaging of GFP-expressing T-cells in mice with non-contact fluorescence moleculartomography [6143-53]
A. Garofalakis, H. Meyer, G. Zacharakis, C. Mamalaki, J. Papamatheakis, V. Ntziachristos, E. Economou, J. Ripoll
Image quantification of high-throughput tissue microarray [6143-54]
J. Wu, J. Dong, H. Zhou
SPECIAL SESSION ON OPTICAL TOMOGRAPHIC IMAGING
Time domain optical molecular imaging of small animals in vivo [6143-55]
D. Hall
Functional imaging of small tissue volumes with diffuse optical tomography [6143-57]
A. Klose, A. Hielscher
Laminar optical tomography: high-resolution 3D functional imaging of superficial tissues [6143-58]
E. Hillman, A. Devor, A. Dunn, D. Boas
POSTER SESSION
Development and use of a kinetic FDG-PET dataset simulated from the MNI standard brain [6143-59]
D. Schottlander, A. Guimond, X. Pan, M. Brady, J. Declerck, L. Collins, A. Evans, A. Reilhac
EEG imaging methods applied to brain-computer interface [6143-61]
Q. Noirhomme, B. Macq
Spatiotemporal analysis of ERP data in emotional processing [6143-62]
J. Hu, J. Tian, L. Yang, X. Pan, J. Liu
Combination of PCA and LORETA for sources analysis of ERP data: an emotional processing study [6143-63]
J. Hu, J. Tian, L. Yang, X. Pan, J. Liu
Neuronal fiber connections based on A*-pathfinding [6143-64]
D. Merhof, F. Enders, P. Hastreiter, O. Ganslandt, R. Fahlbusch, C. Nimsky, M. Stamminger
Parameterization of motion artifacts in fMRI time series using autoregressive models for theconstruction of computer-generated phantoms [6143-66]
Y. Li, V. Morgan, D. Pickens, B. Dawant
Constrained triple-component T2 quantification in vivo [6143-69]
J. Jain, W. Reddick
Regional gray matter abnormalities in patients with schizophrenia determined with optimized voxel-based morphometry [6143-70]
X. Guo, L. Yao, Z. Jin, K. Chen
Investigation of a block matching algorithm for determining spatial constraints in morphometric analysis[6143-71]
T. Sinha, M. Miga
Plexus structure imaging with thin slab MR neurography: rotating frames, fly-throughs, and compositeprojections [6143-72]
D. Raphael, D. McIntee, J. Tsuruda, P. Colletti, R. Tatevossian, J. Frazier
Integrated modeling of PET and DTI information based on conformal brain mapping [6143-73]
G. Zou, Y. Xi, G. Heckenburg, Y. Duan, J. Hua, X. Gu
Uterine fibroid segmentation and volume measurement on MRI [6143-74]
J. Yao, D. Chen, W. Lu, A. Premkumar
Measurement of pelvic osteolytic lesions in follow-up studies after total hip arthroplasty [6143-75]
B. Castaneda, J. Tamez-Pena, S. Totterman, R. O'Keefe, R. Looney
An intensity standardization-based method for inhomogeneity correction in MRI [6143-76]
Y. Zhuge, J. Udupa, J. Liu, P. Saha
Optimized motion estimation for MRE data with reduced motion encodes [6143-77]
H. Wang, J. Weaver, M. Doyley, Q. Feng, F. Kennedy, K. Paulsen
Statistical parametric mapping for in vivo MRI assessment of morphological changes in rat articularcartilage [6143-78]
P. Chiao, Z. Xie, S. Dhamija, S. Liachenko, M. Gieseg
3D shape description of the bicipital groove of the proximal humerus [6143-79]
A. Ward, M. Schweitzer, G. Hamarneh
Motion analysis of knee joint using dynamic volume images [6143-80]
H. Haneishi, T. Kohno, M. Suzuki, H. Moriya, S. Mori, M. Endo
Multi-angle deformation analysis of Hoffa's fat pad [6143-81]
K. Stevenson, M. Schweitzer, G. Hamarneh
Real-time deformations of organ based on structural mechanics for surgical simulators [6143-82]
T. Nakaguchi, M. Tagaya, N. Tamura, N. Tsumura, Y. Miyake
Image based hemodynamic modeling of cerebral aneurysms and the determination of the risk ofrupture [6143-83]
D. Kroon, C. Slump, M. Sluzewski, W. van Rooij
Towards a patient-specific modeling II: biomechanics of a growing aneurysm [6143-84]
S. Baek, C. Figueroa, C. Taylor, J. Humphrey
Computational fluid dynamics of abdominal aortic aneurysms with patient-specific inflow boundaryconditions [6143-85]
U. Kose, S. de Putter, R. Hoogeveen, M. Breeuwer
Local influence of calcifications on the wall mechanics of abdominal aortic aneurysm [6143-86]
S. de Putter, F. van de Vosse, M. Breeuwer, F. Gerritsen
Evaluation of an asymmetric stent patch design for a patient specific intracranial aneurysm usingcomputational fluid dynamic (CFD) calculations in the computed tomography (CT) derived lumen [6143-88]
M. Kim, C. Ionita, R. Tranquebar, K. Hoffmann, D. Taulbee, H. Meng, S. Rudin
Vessel cross-section determination based on nonrigid registration and electric field model [6143-89]
D. Kang, W. Seong, J. Ra
Digital densitometric determination of clinical relative coronary flow distributions [6143-90]
G. ten Brinke, C. Slump, C. Storm
Blood flow measurement by cone-beam CT bolus imaging [6143-91]
Z. Chen, R. Ning, D. Conover, X. Lu
Gender-specific statistical models of pathological coronary arteries for generating simulated angiograms[6143-92]
I. Kyprianou, L. Thompson, D. Banh, W. Pritchard, J. Karanian, L. Rosen, K. Myers
Subtraction computed tomographic angiography: use of pre-contrast images for calcification removal[6143-93]
P. Yim, J. Nosher
On the assumption of cubic graphs of vascular networks [6143-95]
S. Cha, S. Chang, M. Gargano
Myocardial physiology measurements using contrast enhanced dynamic computed tomography:simulation of beam hardening effect [6143-96]
M. Cao, K. Stantz, Y. Liang
A method for myocardial contraction force reconstruction for tissue viability assessment [6143-97]
C. Linte, T. Peters, A. Samani
Artifact reduction in HARP strain maps using anisotropic smoothing [6143-98]
K. Abd-Elmoniem, V. Parthasarathy, J. Prince
Accurate recovery of 4D left ventricular deformations using volumetric B-splines incorporating phasebased displacement estimates [6143-99]
J. Chen, N. Tustison, A. Amini
Airway morphometry in the lungs as depicted in chest CT examinations variability of measurements[6143-100]
J. Leader, B. Zheng, F. Scuirba, H. Coxson, J. Weissfeld, C. Fuhrman, G. Maitz, D. Gur
CT acquisition technique and quantitative analysis of the lung parenchyma: variability and corrections[6143-101]
B. Zheng, J. Leader, H. Coxson, F. Scuirba, C. Fuhrman, A. Balkan, J. Weissfeld, G. Maitz, D. Gur
Algorithm of pulmonary emphysema extraction using low dose thoracic 3D CT images [6143-102]
S. Saita, M. Kubo, Y. Kawata, N. Niki, Y. Nakano, H. Omatsu, K. Tominaga, K. Eguchi, N. Moriyama
A volumetric pulmonary CT segmentation method with applications in emphysema assessment [6143-103]
J. Silva, A. Silva, B. Santos
Unsupervised extraction and quantification of the bronchial tree on ultra-low-dose vs. standard-dose CT[6143-104]
R. Wiemker, A. Ekin, R. Opfer, T. Bülow, P. Rogalla
Automated anatomical labeling algorithm of bronchial branches based on multi-slice CT images [6143-105]
J. Kawai, S. Saita, M. Kubo, Y. Kawata, N. Niki, Y. Nakano, H. Nishitani, H. Ohmatsu, K. Eguchi, N. Moriyama
Feature calculation for classification algorithm of pulmonary vein and artery [6143-106]
T. Nishio, S. Saita, M. Kubo, Y. Kawata, N. Niki, H. Ohmatsu, R. Kakinuma, N. Moriyama, K. Eguchi
Quantification and visualization of relative local ventilation on dynamic chest radiographs [6143-107]
R. Tanaka, S. Sanada, N. Okazaki, T. Kobayashi, K. Nakayama, T. Matsui, N. Hayashi, O. Matsui
High resolution multi-detector CT aided tissue analysis and quantification of lung fibrosis [6143-108]
V. Zavaletta, R. Karwoski, B. Bartholmai, R. Robb
Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)[6143-109]
C. McCollough, J. Zhang, M. Bruesewitz, B. Bartholmai
Multislice CT perfusion imaging of the lung in detection of pulmonary embolism [6143-110]
H. Hong, J. Lee
Measuring blood delivery to solitary pulmonary nodules using perfusion magnetic resonance imaging[6143-111]
W. Zheng, Z. Wang, L. Shen, L. Gao, J. Ford, F. Makedon, J. Pearlman
Growth-rate estimation of pulmonary nodules in three-dimensional thoracic CT images based on CTdensity histogram analysis and its application to nodule classification [6143-112]
Y. Kawata, M. Nakaoka, N. Niki, H. Ohmatsu, M. Kusumoto, R. Kakinuma, K. Eguchi, M. Kaneko, N. Moriyama
Classifying pulmonary nodules using dynamic enhanced single slice and multi slice CT images [6143-113]
K. Minami, Y. Kawata, N. Niki, H. Ohmatsu, M. Kusumoto, K. Yamada, R. Kakinuma, K. Eguchi, K. Mori, M. Kaneko, N. Moriyama
The effect of edge-preserving image smoothing on automatic colonic polyp detection for CTcolonography [6143-114]
D. Pilkinton, I. Bitter, R. Summers, S. Campbell, J. Choi, P. Pickhardt
Wavelet analysis in virtual colonoscopy [6143-115]
S. Greenblum, J. Li, A. Huang, R. Summers
Determining patient 6-degrees-of-freedom motion from stereo infrared cameras during supine medicalimaging [6143-116]
R. Beach, B. Feng, M. Shazeeb, M. King
A new method for the quantitative analysis of gated SPECT polar scintigraphic maps [6143-117]
F. Tanzi, R. Novario, C. Bianchi, U. Nocco, S. Garancini, L. Conte
Comparing two electrical impedance tomography algorithms: Gauss-Newton and topology optimization[6143-118]
L. Motta-Mello, C. Lima, J. Aya, C. Pai, F. Moura, E. Silva, R. Gonzalez-Lima
Skin surface removal on breast microwave imagery using wavelet multiscale products [6143-119]
D. Flores-Tapia, G. Thomas, S. Pistorius
Optimal segmentation of the optic nerve head from stereo retinal images [6143-120]
M. Merickel, Jr., X. Wu, M. Sonka, M. Abramoff
Validation of a fiber-based confocal microscope for interventional image-guided procedures:correlation with multispectral optical imaging [6143-122]
D. Herzka, J. Quijano, J. Xie, S. Krueger, S. Weiss, B. Abrat, A. Osdoit, C. Cavé, C. Burnett, S. Danthi, K. Li
Computation of brain neurodegeneration in the Alzheimer's fly [6143-123]
P. Lee, Y. Huang, H. Chang, A. Chiang, Y. Ching
Cone beam computed tomography angiogenesis imaging: preliminary studies [6143-125]
D. Conover, R. Ning, S. Paoni, I. Wilson, X. Lu, Y. Zhang, B. Fenton
Reproducibility of 3D micro-CT gray-scale and structural dimension data in longitudinal studies [6143-126]
S. Jorgensen, D. Eaker, A. Vercnocke, E. Ritman
Finite element model-based tumor registration of microPET and high-resolution MR images forphotodynamic therapy in mice [6143-127]
B. Fei, H. Wang, R. Muzic, Jr., C. Flask, D. Feyes, D. Wilson, J. Duerk, N. Oleinick
Volume 6144 Medical Imaging 2006: Image Processing
Chairs/Editors: Joseph M. Reinhardt, Josien P. W. Pluim
Conference Committee
Introduction
SEGMENTATION I
Image segmentation using local shape and gray-level appearance models [6144-1]
D. Seghers, D. Loeckx, F. Maes, P. Suetens
Toward fully automatic object detection and segmentation [6144-2]
H. Schramm, O. Ecabert, J. Peters, V. Philomin, J. Weese
Automatic generation of dynamic 3D models for medical segmentation tasks [6144-3]
L. Dornheim, J. Dornheim, K. Tönnies
Oriented active shape models [6144-4]
J. Liu, J. Udupa
Segmentation by surface-to-image registration [6144-5]
Z. Xie, J. Tamez-Pena, M. Gieseg, S. Liachenko, S. Dhamija, P. Chiao
SEGMENTATION II
Robust local intervertebral disc alignment for spinal MRI [6144-6]
J. Reisman, J. Höppner, S. Huang, L. Zhang, S. Lai, B. Odry, C. Novak
Level set based vertebra segmentation for the evaluation of Ankylosing Spondylitis [6144-7]
S. Tan, J. Yao, M. Ward, L. Yao, R. Summers
Segmentation of hand radiographs using fast marching methods [6144-8]
H. Chen, C. Novak
Knowledge-based segmentation of the heart from respiratory-gated CT datasets acquired without cardiaccontrast-enhancement [6144-9]
J. Dey, T. Pan, D. Choi, M. Smyczynski, H. Pretorius, M. King
Automatic cardiac MRI myocardium segmentation using graphcut [6144-10]
G. Kedenburg, C. Cocosco, U. Köthe, W. Niessen, E. Vonken, M. Viergever
Anatomical-based segmentation with stenosis bridging and gap closing in atherosclerotic cardiac MSCT[6144-11]
R. Merges, D. Rinck, M. Sühling, O. Dössel, M. Scheuering
TEXTURE
Quantifying changes in the bone microarchitecture using Minkowski-functionals and scaling vectors:a comparative study [6144-12]
C. Raeth, D. Mueller, T. Link, H. Boehm, R. Monetti
Variogram methods for texture classification of atherosclerotic plaque ultrasound images [6144-13]
O. Jeromin, M. Pattichis, C. Pattichis, E. Kyriacou, A. Nicolaides
Optimizing texture measures quantifying bone structures as well as MR-sequences at 3 Tesla:an integrative statistical approach [6144-17]
C. Raeth, D. Mueller, E. Rummeny, T. Link, M. Vogel, H. Koenig, H. Boehm, R. Monetti
Analysis of parenchymal patterns using conspicuous spatial frequency features in mammogramsapplied to the BI-RADS density rating scheme [6144-15]
P. Perconti, M. Loew
Mammographic density measured as changes in tissue structure caused by HRT [6144-16]
J. Raundahl, M. Loog, M. Nielsen
Early detection of glaucoma using fully automated disparity analysis of optic nerve head (ONH) fromstereo fundus images [6144-201]
A. Sharma, E. Corona, S. Mitra, B. Nutter
SEGMENTATION III
Automatic segmentation of vessels in breast MR sequences as a false positive elimination techniquefor automatic lesion detection and segmentation using the shape tensor [6144-18]
G. Hermosillo, X. Jiang
A dorsolateral prefrontal cortex semi-automatic segmenter [6144-19]
R. Al-Hakim, J. Fallon, D. Nain, J. Melonakos, A. Tannenbaum
Competitive segmentation of the hippocampus and the amygdala from MRI data: validation on younghealthy controls and Alzheimer’s disease patients [6144-20]
M. Chupin, D. Hasboun, R. Mukuna-Bantumbakulu, E. Bardinet, S. Baillet, S. Kinkingnéhun, L. Lemieux, B. Dubois, L. Garnero
Improved 3D live-wire method with application to 3D CT chest image analysis [6144-21]
K. Lu, W. Higgins
Automatic segmentation of pulmonary nodules on CT images by use of NCI lung image databaseconsortium [6144-22]
R. Tachibana, S. Kido
Automatic segmentation of pulmonary fissures in x-ray CT images using anatomic guidance [6144-23]
S. Ukil, M. Sonka, J. Reinhardt
MULTIRESOLUTION AND WAVELETS
A pseudo wavelet-based method for accurate tagline tracing on tagged MR images of the tongue [6144-25]
X. Yuan, C. Ozturk, G. Chi-Fishman
An improved method of wavelet image fusion for extended depth-of-field microscope imaging [6144-26]
S. Cheng, Q. Wu, H. Choi, K. Castleman
Three-band MRI image fusion utilizing the wavelet-based method optimized with two quantitativefusion metrics [6144-27]
Y. Zheng, A. Elmaghraby, H. Frigui
REGISTRATION I
Large-scale validation of non-rigid registration algorithms for atlas-based brain image segmentation[6144-28]
Q. Wang, E. D'Agostino, D. Seghers, F. Maes, D. Vandermeulen, P. Suetens
Multi-modal inter-subject registration of mouse brain images [6144-29]
X. Li, T. Yankeelov, G. Rosen, J. Gore, B. Dawant
Improved method for correction of systematic bias introduced by the sub-voxel image registrationprocess in functional magnetic resonance imaging (fMRI) [6144-30]
D. Wu, J. Suri, V. Magnotta, T. Przebinda, V. DeBrunner
Quantification of the migration and deformation of abdominal aortic aneurysm stent grafts [6144-31]
J. Mattes, I. Steingruber, M. Netzer, K. Fritscher, H. Kopf, W. Jaschke, R. Schubert
Deformable registration of abdominal CT images: tissue stiffness constraints using B-splines [6144-32]
J. West, C. Maurer, Jr., J. Dooley, G. Rohde
Multi-modal 2D-3D non-rigid registration [6144-33]
M. Prümmer, J. Hornegger, M. Pfister, A. Dörfler
REGISTRATION II
Explicit rigid and similarity image registration [6144-34]
O. Škrinjar, M. Khan
On the alignment of shapes represented by Fourier descriptors [6144-35]
K. Sjöstrand, A. Ericsson, R. Larsen
Mjolnir: deformable image registration using feature diffusion [6144-36]
L. Ellingsen, J. Prince
Non-rigid brain image registration using a statistical deformation model [6144-37]
J. Wouters, E. D'Agostino, F. Maes, D. Vandermeulen, P. Suetens
Nonrigid registration using regularization that accommodates local tissue rigidity [6144-38]
D. Ruan, J. Fessler, M. Roberson, J. Balter, M. Kessler
Nonrigid registration using a rigidity constraint [6144-39]
M. Staring, S. Klein, J. Pluim
REGISTRATION III
Reconstruction of 4D-CT data sets acquired during free breathing for the analysis of respiratory motion[6144-40]
J. Ehrhardt, R. Werner, T. Frenzel, D. Säring, W. Lu, D. Low, H. Handels
Globally optimal model-based matching of anatomical trees [6144-41]
M. Graham, W. Higgins
A comparison of FFD-based nonrigid registration and AAMs applied to myocardial perfusion MRI [6144-42]
H. Ólafsdóttir, M. Stegmann, B. Ersbøll, H. Larsson
Cardiac motion estimation by using high-dimensional features and K-means clustering method [6144-43]
E. Oubel, A. Hero, A. Frangi
Registration of 2D cardiac images to real-time 3D ultrasound volumes for 3D stress echocardiography[6144-44]
K. Leung, M. van Stralen, M. Voormolen, G. van Burken, A. Nemes, F. ten Cate, M. Geleijnse, N. de Jong,A. van der Steen, J. Reiber, J. Bosch
Real-time registration by tracking for MR-guided cardiac interventions [6144-45]
D. Chung, J. Satkunasingham, G. Wright, P. Radau
RESTORATION AND FILTERING
A homomorphic filtering framework for DT-MRI [6144-46]
C. Castaño-Moraga, C. Westin, J. Ruiz-Alzola
Theoretical framework for analyzing MR imaging of dynamic objects using filters and downsamplers[6144-47]
H. Agarwal, J. Prince
A novel strategy for segmentation of magnetic resonance (MR) images corrupted by intensityinhomogeneity artifacts [6144-48]
W. Chen, M. Giger
Apparent diffusion profile estimation from high angular resolution diffusion images [6144-49]
M. Descoteaux, E. Angelino, S. Fitzgibbons, R. Deriche
Restoration of 3D medical images with total variation scheme on wavelet domains (TVW) [6144-50]
A. Ogier, P. Hellier, C. Barillot
A pixelwise inpainting-based refinement scheme for quantizing calcification in the lumbar aorta on 2Dlateral x-ray images [6144-51]
L. Conrad-Hansen, M. de Bruijne, F. Lauze, L. Tanko, M. Nielsen
SHAPE
Sparse modeling of landmark and texture variability using the orthomax criterion [6144-52]
M. Stegmann, K. Sjöstrand, R. Larsen
A representation and classification scheme for tree-like structures in medical images: an application onbranching pattern analysis of ductal trees in x-ray galactograms [6144-53]
V. Megalooikonomou, D. Kontos, J. Danglemaier, A. Javadi, P. Bakic, A. Maidment
Three-dimensional analysis of alveolar bone resorption by image processing of 3-D dental CT images[6144-54]
J. Nagao, T. Kitasaka, K. Mori, Y. Suenaga, S. Yamada, M. Naitoh
Optimal landmark distributions for statistical shape model construction [6144-55]
T. Heimann, I. Wolf, H. Meinzer
An ISO-surface folding analysis method applied to premature neonatal brain development [6144-56]
C. Rodriguez-Carranza, F. Rousseau, B. Iordanova, O. Glenn, D. Vigneron, J. Barkovich, C. Studholme
Image-based metrology of porous tissue engineering scaffolds [6144-57]
S. Rajagopalan, R. Robb
PATTERN RECOGNITION
Automated planning of MRI neuro scans [6144-58]
S. Young, D. Bystrov, T. Netsch, R. Bergmans, A. van Muiswinkel, F. Visser, R. Sprigorum, J. Gieseke
A classification framework for content-based extraction of biomedical objects from hierarchicallydecomposed images [6144-59]
C. Thies, M. Schmidt Borreda, T. Seidl, T. Lehmann
A pattern recognition approach to enhancing structures in 3D CT data [6144-60]
E. van Rikxoort, B. van Ginneken
Blood detection in wireless capsule endoscopy using expectation maximization clustering [6144-61]
S. Hwang, J. Oh, J. Cox, S. Tang, H. Tibbals
Functional feature subspace mapping of fMRI data in the spectral domain [6144-62]
L. Yang, J. Tian, J. Hu, J. Liu
Analysis of first-pass myocardial perfusion MRI using independent component analysis [6144-63]
J. Milles, R. van der Geest, M. Jerosch-Herold, J. Reiber, B. Lelieveldt
Using image similarity and asymmetry to detect breast cancer [6144-64]
D. Tahmoush, H. Samet
CAD I
Probabilistic nodule filtering in thoracic CT scans [6144-65]
C. Wu, G. Agam
Development of a computerized scheme for detection of very subtle lung nodules located in opaqueareas on chest radiographs [6144-66]
J. Shiraishi, Q. Li, K. Doi
Computerized detection of pulmonary nodules using a combination of 3D global and local shapeinformation based on helical CT images [6144-67]
X. Zhang, J. Stockel, M. Wolf, P. Cathier, G. McLennan, E. Hoffman, M. Sonka
Automated detection of ureter abnormalities on multi-detector row CT urography [6144-68]
L. Hadjiiski, B. Sahiner, E. Caoili, R. Cohan, H. Chan
Biplane correlation imaging for lung nodule detection: initial human subject results [6144-69]
N. Majdi Nasab, E. Samei, J. Dobbins III
Increasing sensitivity of masses cued on both views by CAD [6144-70]
B. Zheng, G. Maitz, J. Leader, D. Gur
CAD II
Reconstruction-independent 3D CAD for mass detection in digital breast tomosynthesis using fuzzyparticles [6144-71]
G. Peters, S. Muller, S. Bernard, R. Iordache, I. Bloch
Micro-calcification detection in digital tomosynthesis mammography [6144-72]
F. Wheeler, A. Perera, B. Claus, S. Muller, G. Peters, J. Kaufhold
Computer-aided detection of breast masses on mammograms: bilateral analysis for false positivereduction [6144-73]
Y. Wu, L. Hadjiiski, J. Wei, C. Zhou, B. Sahiner, H. Chan
Digital bowel cleansing for computer-aided detection of polyps in fecal-tagging CT colonography [6144-74]
W. Cai, J. Näppi, M. Zalis, G. Harris, H. Yoshida
Quantitative analysis of two-phase 3D+time aortic MR images [6144-75]
F. Zhao, H. Zhang, N. Walker, F. Yang, M. Olszewski, A. Wahle, T. Scholz, M. Sonka
Two-view information fusion for improvement of computer-aided detection (CAD) of breast masses onmammograms [6144-76]
J. Wei, B. Sahiner, L. Hadjiiski, H. Chan, M. Helvie, M. Roubidoux, C. Zhou, J. Ge, Y. Zhang
Comparison of breast ductal branching pattern classification using x-ray galactograms and MRautogalactograms [6144-77]
P. Bakic, M. Rosen, A. Maidment
REGISTRATION POSTER SESSION
Validation of elastic registration algorithms based on adaptive irregular grids for medical applications[6144-78]
A. Franz, I. Carlsen, S. Renisch, H. Wischmann
A strategy based on maximum spanning trees to stitch together microscope images [6144-79]
P. Thévenaz, D. Lambiel, M. Unser
Weighted medical image registration with automatic mask generation [6144-80]
H. Schumacher, A. Franz, B. Fischer
Dedicated registration for DCE MRI mammography [6144-81]
S. Renisch, T. Bülow, I. Carlsen, A. Franz
A linear programming based algorithm for determining corresponding point tuples in multiple vascularimages [6144-82]
V. Singh, J. Xu, K. Hoffmann, P. Noël, A. Walczak
Non-rigid registration for fusion of carotid vascular ultrasound and MRI volumetric datasets [6144-83]
R. Chan, S. Sokka, D. Hinton, S. Houser, R. Manzke, A. Hanekamp, V. Reddy, M. Kaazempur-Mofrad, V. Rasche
Evaluation of similarity measures for 3D/2D image registration [6144-84]
D. Škerl, B. Likar, F. Pernuš
Deformable registration using scale space keypoints [6144-85]
M. Moradi, P. Abolmaesoumi, P. Mousavi
Automatic sub-volume registration by probabilistic random search [6144-86]
J. Han, M. Qiao, J. Hornegger, T. Kuwert, W. Bautz, W. Römer
Physics-based constraints for correction of geometric distortions in gradient echo EP images vianonrigid registration [6144-87]
Y. Li, N. Xu, J. Fitzpatrick, V. Morgan, D. Pickens, B. Dawant
An ITK framework for deterministic global optimization for medical image registration [6144-88]
F. Dru, M. Wachowiak, T. Peters
Optical flow based interpolation of temporal image sequences [6144-89]
J. Ehrhardt, D. Säring, H. Handels
Modeling lung motion using consistent image registration in 4D computed tomography for radiation therapy[6144-90]
W. Lu, J. Song, G. Christensen, P. Parikh, J. Bradley, D. Low
Enhancing skeletal features in digitally reconstructed radiographs [6144-92]
D. Fu, G. Kuduvalli
Fully automatic hybrid registration method based on point feature detection without user intervention[6144-93]
B. Koo, J. Lee, J. Kim, I. Kim, J. Kwon, S. Kim
A variational approach to spatially dependent non-rigid registration [6144-94]
F. Jäger, J. Han, J. Hornegger, T. Kuwert
A practical salient region feature based 3D multi-modality registration method for medical images [6144-95]
D. Hahn, G. Wolz, Y. Sun, J. Hornegger, F. Sauer, T. Kuwert, C. Xu
A framework for parameter optimization in mutual information (MI)-based registration algorithms
G. Gopalakrishnan, S. Bharath Kumar, R. Mullick, A. Narayanan, S. Suryanarayanan
Seed based registration for intraoperative brachytherapy dosimetry: a comparison of methods [6144-97]
Y. Su, B. Davis, M. Herman, R. Robb
Image registration using shape-constrained mutual information and genetic algorithms [6144-98]
X. Yuan, G. Chi-Fishman
Automatic lung nodule matching for the follow-up in temporal chest CT scans [6144-99]
H. Hong, J. Lee, Y. Shin
Distance transform for automatic dermatologic images composition [6144-100]
C. Grana, G. Pellacani, S. Seidenari, R. Cucchiara
Registration and 3D visualization of large microscopy images [6144-101]
K. Mosaliganti, T. Pan, R. Sharp, R. Ridgway, S. Iyengar, A. Gulacy, P. Wenzel, A. de Bruin, R. Machiraju, K. Huang,G. Leone, J. Saltz
Registration of knee joint surfaces for the in vivo study of joint injuries based on magnetic resonanceimaging [6144-102]
R. Cheng, A. Habib, R. Frayne, J. Ronsky
Elastic registration using 3D ChainMail: application to virtual colonoscopy [6144-104]
C. Castro-Pareja, B. Daly, R. Shekhar
Automated feature-based alignment for 3D volume reconstruction of CLSM imagery [6144-105]
S. Lee, P. Bajcsy
Automatic 3D image registration using voxel similarity measurements based on a genetic algorithm[6144-106]
W. Huang, J. Sullivan, Jr., P. Kulkarni, M. Murugavel
Improved 2D/3D registration robustness using local spatial information [6144-107]
E. De Momi, K. Eckman, B. Jaramaz, A. DiGioia III
Vessel-based registration with application to nodule detection in thoracic CT scans [6144-108]
C. Wu, G. Agam
Mathematical properties of information theoretic image similarity measures [6144-109]
O. Škrinjar
Fast surface alignment for cardiac spatio-temporal modeling: application to Ischemic cardiac shapemodeling [6144-110]
H. Huang, L. Shen, R. Zhang, F. Makedon, B. Hettleman, J. Pearlman
Iterative deformable FEM model for nonrigid PET/MRI breast image coregistration [6144-111]
M. Unlu, A. Krol, A. Magri, D. Feiglin, J. Mandel, E. Lipson, I. Coman, W. Lee, G. Tillapaugh-Fay
Temporal registration of 2D x-ray mammogram using triangular B-splines finite element method (TBFEM)[6144-112]
K. Wang, Y. He, H. Qin, P. Fisher, W. Zhao
Establishing multi-modality datasets with the incorporation of 3D histopathology for soft tissueclassification [6144-113]
J. de Ryk, J. Thiesse, J. Reinhardt, E. Hoffman, G. McLennan
Initial comparison of registration and fusion of SPECT-CmT mammotomography images [6144-114]
E. Dura, P. Madhav, S. Cutler, T. Turkington, M. Tornai
Motion correction via nonrigid coregistration of dynamic MR mammography series [6144-115]
A. Krol, A. Magri, M. Unlu, D. Feiglin, E. Lipson, J. Mandel, G. Tillapaugh-Fay, W. Lee, I. Coman, N. Szeverenyi
Alignment of full and partial CT thoracic scans using bony structures [6144-116]
M. Gavrielides, N. Petrick, K. Myers
Image registration of proximal femur with substantial bone changes: application in 3D visualization ofbone loss of astronauts after long-duration spaceflight [6144-117]
W. Li, M. Sode, I. Saeed, T. Lang
Supporting registration decisions during 3D medical volume reconstructions [6144-119]
P. Bajcsy, S. Lee, D. Clutter
SEGMENTATION POSTER SESSION
An automatic segmentation method for multispectral microscopic cervical cell images [6144-120]
H. Zhang, L. Zeng, H. Ke, J. Lei, X. Xu, H. Zheng, Q. Wu, D. Wang, Y. Zhang
Characterization of the optic disc in retinal imagery using a probabilistic approach [6144-121]
K. Tobin, Jr., E. Chaum, V. Govindasamy, T. Karnowski, O. Sezer
Automatic segmentation method which divides a cerebral artery tree in time-of-flight MR-angiographyinto artery segments [6144-122]
A. Takemura, M. Suzuki, H. Harauchi, Y. Okumura, T. Umeda
SIBS, a powerful concept for automatic segmentation of electron tomograms [6144-123]
A. Linaroudis, R. Hegerl
Generalized expectation-maximization segmentation of brain MR images [6144-124]
A. Devalkeneer, P. Robe, J. Verly, C. Phillips
Texture-based instrument segmentation in 3D ultrasound images [6144-125]
M. Linguraru, R. Howe
Vasculature segmentation for radio frequency ablation of non-resectable hepatic tumors [6144-126]
P. Hemler, E. McCreedy, R. Cheng, B. Wood, M. McAuliffe
kNN-based multi-spectral MRI brain tissue classification: manual training versus automated atlas-basedtraining [6144-127]
H. Vrooman, C. Cocosco, R. Stokking, M. Ikram, M. Vernooij, M. Breteler, W. Niessen
Fully-automated analysis of multi-resolution four-channel micro-array genotyping data [6144-128]
M. Abbaspour, R. Abugharbieh, M. Podder, S. Tebbutt
Iterative live wire and live snake: new user-steered 3D image segmentation paradigms [6144-129]
A. Souza, J. Udupa, G. Grevera, Y. Sun, D. Odhner, N. Suri, M. Schnall
Automatic LV volume measurement in low dose multi-phase CT by shape tracking [6144-130]
J. von Berg, P. Begemann, F. Stahmer, G. Adam, C. Lorenz
Fast, shape-directed, landmark-based deep gray matter segmentation for quantification of iron deposition[6144-131]
A. Ekin, R. Jasinschi, J. van der Grond, M. van Buchem, A. van Muiswinkel
Automated brain segmentation using neural networks [6144-132]
S. Powell, V. Magnotta, H. Johnson, N. Andreasen
Modeling shape variability for full heart segmentation in cardiac computed-tomography images [6144-133]
O. Ecabert, J. Peters, J. Weese
Comparison of color clustering algorithms for segmentation of dermatological images [6144-134]
R. Melli, C. Grana, R. Cucchiara
MATLAB-ITK interface for medical image filtering, segmentation, and registration [6144-135]
V. Chu, G. Hamarneh
An adipose segmentation and quantification scheme for the intra abdominal region on minipigs [6144-136]
R. Engholm, A. Dubinskiy, R. Larsen, L. Hanson, B. Christoffersen
Computerized method for automated measurement of thickness of cerebral cortex for 3-D MR images[6144-137]
H. Arimura, T. Yoshiura, S. Kumazawa, H. Koga, S. Sakai, F. Mihara, H. Honda, M. Ohki, F. Toyofuku, Y. Higashida
A two-stage method for lesion segmentation on digital mammograms [6144-138]
Y. Yuan, M. Giger, K. Suzuki, H. Li, A. Jamieson
Automatic determination of the imaging plane in lumbar MRI [6144-139]
T. Masaki, Y. Lee, D. Tsai, M. Sekiya, K. Kazama
White matter fiber tractography based on a directional diffusion field in diffusion tensor MRI [6144-140]
S. Kumazawa, T. Yoshiura, H. Arimura, F. Mihara, H. Honda, Y. Higashida, F. Toyofuku
Fuzzy C-mean clustering on kinetic parameter estimation with generalized linear least square algorithmin SPECT [6144-141]
H. Choi, L. Wen, S. Eberl, D. Feng
Segmentation of ground glass opacities by asymmetric multi-phase deformable model [6144-142]
Y. Yoo, H. Shim, I. Yun, K. Lee, S. Lee
Semi-automatic knee cartilage segmentation [6144-144]
E. Dam, J. Folkesson, P. Pettersen, C. Christiansen
Fast and robust extraction of centerlines in 3D tubular structures using a scattered-snakelet approach[6144-145]
C. Spuhler, M. Harders, G. Székely
Analysis of brain images using the 3D-CSC segmentation method [6144-146]
L. Priese, F. Schmitt, P. Sturm, H. Wang, R. Matern, R. Wickenhöfer
3D echocardiographic segmentation using the mean-shift algorithm and an active surface model [6144-147]
N. Felix-Gonzalez, R. Valdes-Cristerna
Level sets and shape models for segmentation of cardiac perfusion MRI [6144-148]
L. Lorenzo, R. MacLeod, R. Whitaker, G. Adluru, E. DiBella
Detection of joint space narrowing in hand radiographs [6144-149]
J. Kauffman, C. Slump, H. Bernelot Moens
Vesselness propagation: a fast interactive vessel segmentation method [6144-151]
W. Cai, F. Dachille, G. Harris, H. Yoshida
Chroma analysis for quantitative immunohistochemistry using active learning [6144-152]
N. Patel, A. Ma, R. Shah, I. Sethi
Probabilistic minimal path for automated esophagus segmentation [6144-153]
M. Rousson, Y. Bai, C. Xu, F. Sauer
Variational segmentation framework in prolate spheroidal coordinates for 3D real-time echocardiography[6144-154]
B. Vallet, E. Angelini, A. Laine
A new general method of 3D model generation for active shape image segmentation [6144-156]
S. Lim, J. Udupa, A. Souza, Y. Jeong, Y. Ho, D. Torigian
A fast algorithm for body extraction in CT volumes [6144-157]
G. Guétat, J. Stoeckel, M. Wolf, A. Krishnan
Investigation on an EM framework for partial volume image segmentation [6144-158]
D. Eremina, X. Li, W. Zhu, J. Wang, Z. Liang
Shortest path adjusted similarity metrics for resolving boundary perturbations in scaffold images fortissue engineering [6144-159]
S. Rajagopalan, R. Robb
Intelligent data splitting for volume data [6144-160]
H. Shen, E. Bartsch
Single click volumetric segmentation of abdominal organs in computed tomography images [6144-161]
B. Whitney, N. Backman, J. Furst, D. Raicu
Fully automatic segmentation of left ventricular myocardium in real-time three-dimensionalechocardiography [6144-162]
V. Walimbe, V. Zagrodsky, R. Shekhar
Pre-operative segmentation of neck CT datasets for the planning of neck dissections [6144-163]
J. Cordes, J. Dornheim, B. Preim, I. Hertel, G. Strauss
Brain extraction using geodesic active contours [6144-164]
A. Huang, R. Abugharbieh, R. Tam, A. Traboulsee
Unsupervised definition of the tibia-femoral joint regions of the human knee and its applications tocartilage analysis [6144-165]
J. Tamez-Peña, M. Barbu-McInnis, S. Totterman
Evaluation of binning strategies for tissue classification in computed tomography images [6144-166]
S. Handrick, B. Naimipour, D. Raicu, J. Furst
Interactive lesion segmentation on dynamic contrast enhanced breast MRI using a Markov model [6144-168]
Q. Wu, M. Salganicoff, A. Krishnan, D. Fussell, M. Markey
Automatic tracking of neuro vascular tree paths [6144-169]
S. Suryanarayanan, A. Gopinath, Y. Mallya, K. Shriram, M. Joshi
Robust optic disk detection in retinal images using vessel structure and radon transform [6144-170]
K. Huang, M. Yan
Prior-shape based segmentation of various objects in ultrasound images after speckle-reduction usinglevel-set based curvature evolution [6144-171]
J. Dey, D. Tighe, G. Vijayaraghavan, V. Mitra, P. Pedersen
Automatic pulmonary vessel segmentation in 3D computed tomographic pulmonary angiographic(CTPA) images [6144-172]
C. Zhou, H. Chan, L. Hadjiiski, S. Patel, P. Cascade, B. Sahiner, J. Wei, J. Ge, E. Kazerooni
Automated segmentation of three-dimensional MR brain images [6144-173]
J. Park, B. Baek, C. Ahn, K. Ku, D. Jeong, C. Lee
Unsupervised clustering of dynamic PET images on the projection domain [6144-174]
M. Kamasak, B. Bayraktar
Content analysis of uterine cervix images: initial steps towards content based indexing and retrieval ofcervigrams [6144-176]
S. Gordon, G. Zimmerman, R. Long, S. Antani, J. Jeronimo, H. Greenspan
SHAPE POSTER SESSION
Topological analysis of 3D cell nuclei using finite element template-based spherical mapping [6144-177]
E. Gladilin, S. Goetze, J. Mateos-Langerak, R. van Driel, R. Eils, K. Rohr
Quantitative comparison of delineated structure shape in radiotherapy [6144-178]
G. Price, C. Moore
Sparse principal component analysis in medical shape modeling [6144-179]
K. Sjöstrand, M. Stegmann, R. Larsen
3D reconstruction of the coronary tree from two X-ray angiographic views [6144-180]
N. Sang, W. Peng, H. Li, Z. Zhang, T. Zhang
Creation of three dimensional craniofacial standards from CBCT images [6144-182]
K. Subramanyan, M. Palomo, M. Hans
Quantifying torso deformity in scoliosis [6144-183]
P. Ajemba, A. Kumar, N. Durdle, V. Raso
CAD POSTER SESSION
AIS TLS-ESPRIT feature selection for prostate tissue characterization [6144-184]
S. Mohamed, A. Youssef, E. El-Saadany, M. Salama
An adaptive image segmentation process for the classification of lung biopsy images [6144-185]
D. McKee, W. Land, Jr., T. Zhukov, D. Song, W. Qian
An automated normative-based fluorodeoxyglucose positron emission tomography image-analysisprocedure to aid Alzheimer disease diagnosis using statistical parametric mapping and interactiveimage display [6144-186]
K. Chen, X. Ge, L. Yao, D. Bandy, G. Alexander, A. Prouty, C. Burns, X. Zhao, X. Wen, R. Korn, M. Lawson, E. Reiman
Lesion margin analysis for automated classification of cervical cancer lesions [6144-187]
V. Van Raad, Z. Xue, H. Lange
Computer-aided diagnosis of splenic enlargement using wave pattern of spleen in abdominal CT images[6144-188]
W. Seong, J. Cho, S. Noh, J. Park
Simulating nodules in chest radiographs with real nodules from multi-slice CT images [6144-189]
A. Schilham, B. van Ginneken
Hot spot detection, segmentation, and identification in PET images [6144-190]
T. Blaffert, K. Meetz
Improving computer-aided diagnosis of interstitial disease in chest radiographs by combining one-classand two-class classifiers [6144-191]
Y. Arzhaeva, D. Tax, B. van Ginneken
Computer aided lytic bone metastasis detection using regular CT images [6144-192]
J. Yao, S. O'Connor, R. Summers
Hybrid committee classifiers for a computerized colonic polyp detection system [6144-193]
J. Li, J. Yao, N. Petrick, R. Summers, A. Hara
Measurement of colonic polyp size from virtual colonoscopy studies: Comparison of manual andautomated methods [6144-194]
M. Gurcan, R. Ernst, A. Oto, S. Worrell, J. Hoffmeister, S. Rogers
Effect of quantization on co-occurrence matrix based texture features: An example study inmammography [6144-195]
G. Lee, M. Bottema, T. Hara, H. Fujita
Development of computerized method for detection of vertebral fractures on lateral chest radiographs[6144-196]
S. Kasai, F. Li, J. Shiraishi, Q. Li, Y. Nie, K. Doi
Automatic colonic polyp detection using multiobjective evolutionary techniques [6144-197]
J. Li, A. Huang, J. Yao, I. Bitter, N. Petrick, R. Summers, P. Pickhardt, J. Choi
False-positive elimination for computer-aided detection of pulmonary micronodules [6144-198]
S. Chang, J. Zhou, D. Metaxas, L. Axel
Confidence-based stratification of CAD recommendations with application to breast cancer detection[6144-199]
P. Habas, J. Zurada, A. Elmaghraby, G. Tourassi
Centerline-based colon segmentation for CAD of CT colonography [6144-200]
J. Näppi, H. Frimmel, H. Yoshida
Local pulmonary structure classification for computer-aided nodule detection [6144-202]
C. Bahlmann, X. Li, K. Okada
Power spectral analysis of mammographic parenchymal patterns [6144-203]
H. Li, M. Giger, O. Olopade
Discrimination of malignant lymphomas and leukemia using Radon transform based-higher order spectra[6144-204]
Y. Luo, M. Celenk, P. Bejai
Computer-aided detection system of breast masses on ultrasound images [6144-205]
Y. Ikedo, D. Fukuoka, T. Hara, H. Fujita, E. Takada, T. Endo, T. Morita
Highly-automated computer-aided diagnosis of neurological disorders using functional brain imaging[6144-206]
P. Spetsieris, Y. Ma, V. Dhawan, J. Moeller, D. Eidelberg
Potential improvement of computerized mass detection on mammograms using a bilateral pairingtechnique [6144-207]
S. Paquerault, N. Petrick, B. Sahiner, K. Myers, H. Chan
Mammographic CADx system using an image library with an intelligent agent: A pattern matchingapproach [6144-208]
S. Lo, M. Freedman, L. Kinnard, E. Makariou
Regularized discriminate analysis for breast mass detection on full field digital mammograms [6144-209]
J. Wei, B. Sahiner, Y. Zhang, H. Chan, L. Hadjiiski, C. Zhou, J. Ge, Y. Wu
Characterization of corresponding microcalcification clusters on temporal pairs of mammograms forinterval change analysis: comparison of classifiers [6144-210]
L. Hadjiiski, D. Drouillard, H. Chan, B. Sahiner, M. Helvie, M. Roubidoux, C. Zhou
Computer-aided detection of clustered microcalcifications on full-field digital mammograms: a two-viewinformation fusion scheme for FP reduction [6144-211]
J. Ge, B. Sahiner, H. Chan, L. Hadjiiski, M. Helvie, C. Zhou, J. Wei, Y. Zhang
Computerized lung nodule detection on screening CT scans: performance on juxta-pleural and internalnodules [6144-212]
B. Sahiner, L. Hadjiiski, H. Chan, C. Zhou, J. Wei
Detection of blue-white veil areas in dermoscopy images using machine learning techniques [6144-213]
M. Celebi, H. Kingravi, Y. Aslandogan, W. Stoecker
Reducing false-positive detections by combining two stage-1 computer-aided mass detectionalgorithms [6144-214]
N. Bedard, M. Sampat, P. Stokes, M. Markey
Combining texture features from the MLO and CC views for mammographic CADx [6144-215]
S. Gupta, D. Zhang, M. Sampat, M. Markey
The influence of CT dose and reconstruction parameters on automated detection of small pulmonarynodules [6144-216]
R. Ochs, E. Angel, K. Boedeker, I. Petkovska, C. Panknin, J. Goldin, D. Aberle, M. McNitt-Gray, M. Brown
MATHEMATICAL MORPHOLOGY POSTER SESSION
An efficient method for computing mathematical morphology for medical imaging [6144-217]
M. Vaz, A. Kiraly
PATTERN RECOGNITION POSTER SESSION
A whole brain morphometric analysis of changes associated with pre-term birth [6144-218]
C. Thomaz, J. Boardman, S. Counsell, D. Hill, J. Hajnal, A. Edwards, M. Rutherford, D. Gillies, D. Rueckert
Feature-space exploration of pathology images using content-based database visualization [6144-219]
B. Lessmann, V. Hans, A. Degenhard, T. Nattkemper
RANSAC-based EM algorithm for robust detection and segmentation of cylindrical fragments fromcalibrated C-arm images [6144-220]
G. Zheng, X. Dong, X. Zhang
Realtime automatic metal extraction of medical x-ray images for contrast improvement [6144-221]
M. Prangl, H. Hellwagner, C. Spielvogel, H. Bischof, T. Szkaliczki
Histologic characterization of DCE-MRI breast tumors with dimensional data reduction [6144-222]
C. Varini, A. Degenhard, T. Nattkemper
Characterization of pulmonary nodules features on computer tomography (CT) scans using waveletcoefficients and heat maps [6144-223]
T. Osicka, M. Freedman, F. Ahmed
QUALITY/RESTORATION/DEBLURRING POSTER SESSION
A new anisotropic diffusion method, application to partial volume effect reduction [6144-224]
O. Salvado, D. Wilson
Metal artifacts reduction in CT images through Euler’s elastica and curvature based sinogram inpainting[6144-226]
J. Gu, L. Zhang, G. Yu, Y. Xing, Z. Chen
A new image calibration technique for colposcopic images [6144-227]
W. Li, M. Soto-Thompson, Y. Xiong, H. Lange
Improved MRSI with field inhomogeneity compensation [6144-228]
I. Khalidov, D. Van De Ville, M. Jacob, F. Lazeyras, M. Unser
Wavelet-based multiscale level-set curve evolution in noise reduction for MR imaging [6144-229]
J. Zhong, B. Dardzinski, J. Wansapura
ICA domain filtering for reduction of noise in x-ray images [6144-230]
Y. Chen, X. Han
Characterization of high resolution MR images reconstructed by a GRAPPA based parallel technique[6144-231]
S. Banerjee, S. Majumdar
Robust estimation of the noise variance from background MR data [6144-232]
J. Sijbers, A. den Dekker, D. Poot, R. Bos, M. Verhoye, N. Van Camp, A. Van der Linden
Improvement of image quality in MDCT by high-frequency sampling of x-, y- and z-direction [6144-233]
N. Yasuda, Y. Ishikawa, Y. Kodera
Automatic detection of specular reflections in uterine cervix images [6144-235]
G. Zimmerman-Moreno, H. Greenspan
Noise reduction from magnetic resonance images using nonseperable transforms [6144-236]
E. Nezhadarya, M. Shamsollahi
An improved denoising algorithm based on multi-scale dyadic wavelet transform [6144-237]
Z. Qi, L. Zhang, Y. Xing, H. Gao
A weighted average algorithm for edge-preserving smoothing on MRI images [6144-238]
R. Jin, L. Zhang, B. Meng, E. Song, X. Xu, C. Hung
Simulation of susceptibility-induced distortions in fMRI [6144-239]
N. Xu, Y. Li, C. Paschal, J. Gatenby, V. Morgan, D. Pickens, B. Dawant, J. Fitzpatrick
Retinal image enhancement based on the human visual system [6144-240]
K. Belkacem-Boussaid, B. Raman, G. Zamora, Y. Srinivasan, S. Bursell
Prior-information-driven multiple contrast projection of T2 weighted magnetic resonance images [6144-241]
S. Rajagopalan, R. Robb
Implications of MR contrast standardization on image computing [6144-242]
S. Rajagopalan, R. Robb
Contrast enhancement of soft tissues in computed tomography images [6144-243]
R. Lerman, D. Raicu, J. Furst
Adaptive conductance filtering for spatially varying noise in PET images [6144-244]
D. Padfield, R. Manjeshwar
Denoising diffusion tensor images: preprocessing for automated detection of subtle diffusion tensorabnormalities between populations [6144-245]
T. Lee, U. Sinha
A voxel-based partial volume correction in nuclear medicine [6144-246]
H. Huang, I. Hsiao, C. Wietholt, C. Hsu
Detectability improvement of early sign of acute stroke on brain CT images using an adaptive partialsmoothing filter [6144-247]
Y. Lee, N. Takahashi, D. Tsai, H. Fujita
A novel contrast equalization method for chest radiograph [6144-248]
M. Zhang, X. Mou, Y. Long
On interpolation of sparsely sampled sinograms [6144-249]
S. Schröder, I. Stuke, T. Aach
STATISTICAL METHODS POSTER SESSION
A new post-processing method of applying independent component analysis to fMRI data [6144-251]
X. Wu, Z. Long, L. Yao, K. Chen
Integrating and classifying parametric features from fMRI data for brain function characterization [6144-252]
Y. Wang, C. Zhou
Enhanced techniques for asymmetry quantification in brain imagery [6144-253]
X. Liu, C. Imielinska, J. Rosiene, E. Connolly, A. D'Ambrosio
TEXTURE POSTER SESSION
Analysis of the topological properties of the proximal femur on a regional scale: evaluation of multi-detector CT-scans for the assessment of biomechanical strength using local Minkowski functionals in 3D[6144-254]
H. Boehm, T. Link, R. Monetti, V. Kuhn, F. Eckstein, C. Raeth, M. Reiser
Automatic textural feature selection on echocardiographic images [6144-255]
I. Ponce García, R. Valdés-Cristerna
Investigation of temporal radiographic texture analysis for the detection of periprosthetic osteolysis[6144-256]
J. Wilkie, M. Giger, C. Engh, Sr., J. Martell
VALIDATION POSTER SESSION
Fourier-domain based datacentric performance ranking of competing medical image processingalgorithms [6144-259]
S. Rajagopalan, R. Robb
Volume 6145 Medical Imaging 2006: PACS and Imaging Informatics
Chairs/Editors: Steven C. Horii, Osman M. Ratib
Conference Committee
DISPLAY AND INTERPRETATION I
MoniQA: a general approach to monitor quality assurance [6145-2]
J. Jacobs, T. Deprez, G. Marchal, H. Bosmans
A method for reduction of eye fatigue by optimizing the ambient light conditions in radiology reading rooms[6145-3]
A. Chawla, E. Samei
DISPLAY AND INTERPRETATION II
Network-based reading system for lung cancer screening CT [6145-5]
Y. Fujino, K. Fujimura, S. Nomura, H. Kawashima, M. Tsuchikawa, T. Matsumoto, K. Nagao, T. Uruma, S. Yamamoto, H. Takizawa, C. Kuroda, T. Nakayama
CMAS: a rich media annotation system for medical imaging [6145-6]
I. Lin, H. Chao
On-demand rendering of an oblique slice through 3D volumetric data using JPEG2000 client-serverframework [6145-8]
R. Joshi
PACS IN SURGERY
Structured recording of intraoperative surgical workflows [6145-10]
T. Neumuth, N. Durstewitz, M. Fischer, G. Strauss, A. Dietz, J. Meixensberger, P. Jannin, K. Cleary, H. Lemke, O. Burgert
Workflow in interventional radiology: nerve blocks and facet blocks [6145-11]
D. Siddoway, M. Ingeholm, O. Burgert, T. Neumuth, V. Watson, K. Cleary
An ultrasound image-guided surgical workflow model [6145-12]
B. Guo, H. Lemke, B. Liu, H. Huang, E. Grant
PACS TECHNOLOGY AND ARCHITECTURE
Peer-to-peer architecture for multi-departmental distributed PACS [6145-14]
A. Rosset, J. Heuberger, L. Pysher, O. Ratib
A demanding web-based PACS supported by web services technology [6145-16]
C. Costa, A. Silva, J. Oliveira, V. Ribeiro, J. Ribeiro
A design methodology for fault-tolerance in a DICOM-compliant data storage grid [6145-17]
J. Documet, Z. Zhou, B. Liu, N. King, H. Huang
Medical image compression using cubic spline interpolation for low bit-rate telemedicine applications[6145-18]
T. Truong, S. Chen
DATABASES AND DATA MINING
Atlas of protein expression: image capture, analysis, and design of terabyte image database [6145-20]
J. Wu, G. Maslen, A. Warford, G. Griffin, J. Xie, S. Crowther, J. McCafferty
Relevance feedback for shape-based pathology in spine x-ray image retrieval [6145-21]
X. Xu, S. Antani, D. Lee, L. Long, G. Thoma
BIRAM: a content-based image retrieval framework for medical images [6145-22]
R. Moreno, S. Furuie
IMAGING INFORMATICS AND STANDARDS
Building an IT healthcare enterprise by taking the standards to the limits and sometimes beyond that[6145-25]
M. Wintell, L. Lindsköld, S. Gustafsson, N. da Silva
A unified approach for the adequate visualization of structured medical reports [6145-26]
J. Riesmeier, M. Eichelberg, T. Wilkens, P. Jensch
IHE cross-enterprise document sharing for imaging: design challenges [6145-27]
R. Noumeir
Three-dimensional lossless digital signature embedding for the integrity of volumetric images [6145-28]
Z. Zhou, H. Huang, B. Liu
A DICOM-RT Based ePR radiation therapy information system for decision-support of brain tumor patients[6145-29]
B. Liu, M. Law, H. Huang, C. Zee, L. Chan
DATA MANAGEMENT AND SECURITY
A tracking and verification system implemented in a clinical environment for partial HIPAA compliance[6145-30]
B. Guo, J. Documet, B. Liu, N. King, R. Shrestha, K. Wang, H. Huang, E. Grant
Technical experiences of implementing a wireless tracking and facial biometric verification system fora clinical environment [6145-31]
B. Liu, J. Lee, J. Documet, B. Guo, N. King, H. Huang
Grid-based medical image workflow and archiving for research and enterprise PACS applications [6145-32]
S. Erberich, M. Dixit, V. Chen, A. Chervenak, M. Nelson, C. Kesselmann
Hierarchical storage of large volume of multidector CT data using distributed servers [6145-33]
O. Ratib, A. Rosset, J. Heuberger, D. Bandon
Tele diagnostic by web [6145-34]
S. Sugiyama
CLINICAL APPLICATIONS
Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helicalCT images [6145-35]
H. Satoh, N. Niki, K. Mori, K. Eguchi, M. Kaneko, R. Kakinuma, N. Moriyama, H. Ohmatsu, H. Masuda, S. Machida, M. SasagawaCarpal bone analysis in bone age assessment [6145-36]
A. Zhang, A. Gertych, S. Kurkowska-Pospiech, B. Liu, H. Huang
Using irreversible compression in digital radiology: a preliminary study of the opinions of radiologists[6145-37]
E. Seeram
MICE: a mouse imaging collaboration environment [6145-38]
J. Szymanski, C. Flask, D. Wilson, D. Johnson, R. Muzic, Jr., G. Zhang
Impact of volumetric ultrasound on PACS [6145-39]
S. Horii, A. Goldszal, R. Redfern, B. Coleman, J. Langer, D. Morton, S. Rowling, W. Boonn, C. Iyoob
POSTER SESSION
Content-based image retrieval in picture archiving and communication system [6145-23]
Y. Tan, J. Zhang, Y. Hua, G. Zhang, H. Huang
The impact of lossless image compression to radiographs [6145-42]
T. Lehmann, J. Abel, C. Weiss
Development of a mobile emergency patient information and imaging communication system based onCDMA-1X EVDO [6145-43]
K. Yang, H. Jung, W. Kang, B. Jang, J. Kim, D. Han, S. Yoo, H. Yoo, H. Kim
Applying XDS for sharing CDA-based medical records [6145-44]
J. Kim, B. Jang, D. Han, K. Yang, W. Kang, H. Jung, H. Kim
The application of multilayer tree structure in DICOM [6145-45]
M. Pan, Z. Yao
Development of patient collation system by kinetic analysis for chest dynamic radiogram with flat paneldetector [6145-46]
Y. Tsuchiya, Y. Kodera
HIPAA-compliant automatic monitoring system for RIS-integrated PACS operation [6145-47]
J. Jin, J. Zhang, X. Chen, J. Sun, Y. Yang, C. Liang, J. Feng, L. Sheng, H. Huang
Interactive radiological education file system integrated with PACS [6145-48]
M. Shin, I. Choi
Sharing medical images: a proposal of a reference image database [6145-49]
M. dos Santos, S. Furuie
Automatic orientation correction for radiographs [6145-50]
H. Luo, J. Luo, X. Wang
Implementation of a fault-tolerant PACS over a grid architecture [6145-51]
M. Gutierrez, C. Santos, R. Moreno, L. Kobayashi, S. Furuie, S. Freire, D. Floriano, C. Oliveira, M. João, R. Gismondi
Integration of LDSE and LTVS logs with HIPAA compliant auditing system (HCAS) [6145-52]
Z. Zhou, B. Liu, H. Huang, B. Guo, J. Documet, N. King
Rib shape recognition in lung x-ray images for intelligent assistance [6145-53]
H. Sakaida, A. Oosawa, K. Shimura
Volume 6146 Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment
Chairs/Editors: Yulei Jiang, Miguel P. Eckstein
Conference Committee
TECHNOLOGY ASSESSMENT AND IMPACT
Can radiologists recognize that a computer has identified cancers that they have overlooked? [6146-1]
R. Nishikawa, A. Edwards, R. Schmidt, J. Papaioannou, M. Linver
Actual versus intended use of CAD systems in the clinical environment [6146-2]
B. Zheng, D. Chough, P. Ronald, C. Cohen, C. Hakim, G. Abrams, M. Ganott, L. Wallace, R. Shah, J. Sumkin, D. Gur
Mass detection in mammographic ROIs using Watson filters [6146-47]
S. Singh, A. Baydush, B. Harrawood, J. Lo
A method for assessing the uncertainty in feature selection tasks [6146-4]
Y. Jiang
Comparative performance analysis for computer aided lung nodule detection and segmentation onultra-low-dose vs. standard-dose CT [6146-5]
R. Wiemker, P. Rogalla, R. Opfer, A. Ekin, V. Romano, T. Bülow
KEYNOTE AND IMAGE DISPLAY
Recent developments and contemporary issues for diagnostic technology assessment [6146-6]
R. Wagner
Potential use of a large-screen display for interpreting radiographic images [6146-7]
E. Krupinski, H. Roehrig, W. Berger, S. Dalal, D. Stanton
Impact of defective pixels in AMLCDs on the perception of medical images [6146-8]
T. Kimpe, Y. Sneyders
Assessment of the influence of display veiling glare on observer and model performance [6146-9]
E. Krupinski, J. Lubin, H. Roehrig, J. Johnson, J. Nafziger
ROC METHODS
Optimization of an ROC hypersurface constructed only from an observer's within-class sensitivities[6146-10]
D. Edwards, C. Metz
Optimal observer framework and categorization observer framework for three-class ROC analysis [6146-11]
X. He, E. Frey
Performance analysis of 3-class classifiers: properties of the 3D ROC surface and the normalizedvolume under the surface [6146-12]
B. Sahiner, H. Chan, L. Hadjiiski
Exploring FROC paradigm: initial experience with clinical applications [6146-13]
L. Volokh, C. Liu, B. Tsui
LROC assessment of non-linear filtering methods in Ga-67 SPECT imaging [6146-14]
S. De Clercq, S. Staelens, J. De Beenhouwer, Y. D'Asseler, I. Lemahieu
OBSERVER PERFORMANCE EVALUATION
Incorporating detection tasks into the assessment of CT image quality [6146-15]
E. Scalzetti, W. Huda, K. Ogden, M. Khan, M. Roskopf, D. Ogden
A comparison of 2D and 3D evaluation methods for pulmonary embolism detection in CT images [6146-42]
A. Kiraly, C. Novak, D. Naidich, I. Vlahos, J. Ko, G. Brusca-Augello
Analyzing the effect of dose reduction on the detection of mammographic lesions using mathematicalobserver models [6146-17]
A. Chawla, R. Saunders, C. Abbey, D. Delong, E. Samei
Parallel reconstructions of MRI: Evaluation using detection and perceptual difference studies [6146-19]
Y. Jiang, D. Huo, D. Wilson
Using perceptual difference model to improve GRAPPA reconstruction in MRI [6146-20]
D. Huo, D. Wilson
MODEL OBSERVERS
The efficiency of reading around learned backgrounds [6146-22]
M. Eckstein, B. Pham, C. Abbey, Y. Zhang
Observer efficiency in boundary discrimination tasks related to assessment of breast lesions withultrasound [6146-23]
C. Abbey, R. Zemp, J. Liu, K. Lindfors, M. Insana
Performance of a channelized-ideal observer using Laguerre-Gauss channels for detecting a Gaussiansignal at a known location in different lumpy backgrounds [6146-24]
S. Park, E. Clarkson, H. Barrett, M. Kupinski, K. Myers
Human efficiency for detecting Gaussian signals in non-Gaussian distributed lumpy backgrounds usingdifferent display characteristics and scaling methods [6146-25]
S. Park, B. Gallas, A. Badano, N. Petrick, K. Myers
IMAGE PERCEPTION
Variability in the interpretation of mammograms: Do similar decisions entail similar visual samplingstrategies? [6146-26]
C. Mello-Thoms
Lesion detection using an a-contrario detector in simulated digital mammograms [6146-27]
B. Grosjean, S. Muller, H. Souchay
Lesion removal and lesion addition algorithms in lung volumetric data sets for perception studies[6146-28]
M. Madsen, K. Berbaum, A. Ellingson, B. Thompson, B. Mullan
Mammographic texture synthesis using genetic programming and clustered lumpy background [6146-29]
C. Castella, K. Kinkel, F. Descombes, M. Eckstein, P. Sottas, F. Verdun, F. Bochud
Perceptually-limited modality-adaptive medical image watermarking [6146-30]
B. Planitz, A. Maeder
Optimum ambient lighting conditions for the viewing of softcopy radiological images [6146-31]
M. McEntee, P. Brennan, M. Evanoff, P. Phillps, W. O Connor, D. Manning
POSTER SESSION
Does mammographic practice affect film reading style: breast screening vs. symptomatic radiologists?[6146-32]
H. Scott, A. Gale
A proposal of the diagnosis-dynamic characteristic (DDC) model describing the relation between searchtime and confidence levels for a dichotomous judgment, and its application to ROC curve generation[6146-33]
T. Matsumoto, N. Fukuda, A. Furukawa, K. Suwa, S. Wada, M. Matsumoto, S. Sone
Observer performance detecting signals in globally non-stationary oriented noise [6146-35]
Y. Zhang, C. Abbey, M. Eckstein
An applicability research on JND model [6146-36]
T. Luo, X. Mou, S. Tang, Y. Yang
How does mass lesion detection vary with display window width and radiation exposure in computedradiography? [6146-37]
K. Ogden, W. Huda, V. Garg, M. Khan, M. Reichel, M. Roskopf
First validation of a new phantom for global quality control in digital mammography [6146-38]
H. Bosmans, K. Nijs, K. Young, F. Rogge, P. Morán, M. Chevalier, M. Borowski, R. van Engen, A. Taibi, J. Cook, G. Marchal
Characterization of a new generation of computed radiography system based on line scanning andphosphor needles [6146-39]
O. Dragusin, F. Rogge, H. Pauwels, G. Marchal, H. Bosmans
Potential for lower absorbed dose in digital mammography: A JAFROC experiment using clinical hybridimages with simulated dose reduction [6146-40]
P. Timberg, M. Ruschin, M. Båth, B. Hemdal, I. Andersson, S. Mattsson, D. Chakraborty, R. Saunders, E. Samei, A. Tingberg
Development and implementation of a user friendly and automated environment for the creation ofdatabases of digital mammograms with simulated microcalcifications [6146-41]
F. Zanca, J. Jacobs, P. Pöyry, C. Van Ongeval, A. Carton, T. Deprez, G. Marchal, H. Bosmans
The effect of data set size on computer-aided diagnosis of breast cancer: comparing decision fusion toa linear discriminant [6146-44]
J. Jesneck, L. Nolte, J. Baker, J. Lo
Comparison of sensitivity and reading time for the use of computer aided detection (CAD) of pulmonarynodules at MDCT as concurrent or second reader [6146-45]
F. Beyer, L. Zierott, E. Fallenberg, K. Juergens, J. Stoeckel, W. Heindel, D. Wormanns
Potential effect of CAD systems on the detection of actionable nodules in chest CT scans during routinereporting [6146-46]
D. Wormanns, F. Beyer, A. Butzbach, L. Zierott, W. Heindel
Explanation of the mechanism by which CAD assistance improves diagnostic performance whenreading CT images [6146-48]
T. Matsumoto, S. Wada, S. Yamamoto, K. Murao, A. Furukawa, M. Endo, M. Matsumoto, S. Sone
Automatic image quality assessment for uterine cervical imagery [6146-51]
J. Gu, W. Li
A study on the performance evaluation of computer-aided diagnosis for detecting pulmonary nodulesfor the various CT reconstruction [6146-52]
S. Wada, T. Matsumoto, K. Murao, S. Sone
Volume 6147 Medical Imaging 2006: Ultrasonic Imaging and Signal Processing
Chairs/Editors: Stanislav Y. Emelianov, William F. Walker
Conference Committee
3D ULTRASOND IMAGING
Evaluation of image compression for computer-aided diagnosis of breast tumors in 3D sonography [6147-1]
W. Chen, Y. Huang, C. Tao, D. Chen, W. Moon
Advanced volume rendering algorithm for real-time 3D ultrasound: integrating pre-integration intoshear-image-order algorithm [6147-2]
R. Managuli, E. Kim, K. Karadayi, Y. Kim
Real-time transrectal 3D ultrasound using synthetic aperture [6147-3]
J. Yen, C. Seo, N. Daher
High resolution three-dimensional prostate ultrasound imaging [6147-4]
Y. Li, A. Patil, J. Hossack
Breast tumor angiogenesis analysis using 3D power Doppler ultrasound [6147-5]
R. Chang, S. Huang, Y. Lee, D. Chen, W. Moon
Multi-view 3D reconstruction with volumetric registration in a freehand ultrasound imaging system
H. Yu, M. Pattichis, M. Goens
Boundary detection in 3D ultrasound reconstruction using nearest neighbor map [6147-7]
P. Pedersen, V. Mitra, J. Dey
BEAMFORMING AND IMAGE PROCESSING
Automatic time gain compensation and dynamic range control in ultrasound imaging systems [6147-8]
D. Lee, Y. Kim, J. Ra
An iterative wavelet-based deconvolution algorithm for the restoration of ultrasound images in an EMframework [6147-9]
J. Ng, R. Prager, N. Kingsbury, G. Treece, A. Gee
Beamforming and hardware design for a multichannel front-end integrated circuit for real-time 3Dcatheter-based ultrasonic imaging [6147-36]
I. Wygant, M. Karaman, Ö. Oralkan, B. Khuri-Yakub
The sonic window: second generation results [6147-11]
W. Walker, M. Fuller, E. Brush, M. Eames, K. Owen, K. Ranganathan, T. Blalock, J. Hossack
Efficient array beamformer using spatial filtering for ultrasound B-mode imaging [6147-12]
K. Kim, J. Liu, M. Insana
Recursive delay calculation unit for parametric beamformer [6147-13]
S. Nikolov, J. Jensen, B. Tomov
Breaking the resolution limit: an exciting experimental result [6147-14]
F. Simonetti
GENERAL IMAGING
Remote consulting based on ultrasonic digital imageing and dynamic ultrasonic sequences [6147-15]
A. Margan, N. Rustemovi
Acoustic properties of healthy and reconstructed cleft lip [6147-16]
J. Thijssen, N. van Hees, G. Weijers, R. Huyskens, M. Nillesen, C. Katsaros, C. de Korte
Integrated system for ultrasonic, photoacoustic and elasticity imaging [6147-17]
S. Park, J. Shah, S. Aglyamov, A. Karpiouk, S. Mallidi, A. Gopal, H. Moon, X. Zhang, W. Scott, S. Emelianov
Breast imaging with time-reversed ultrasound [6147-18]
L. Huang, N. Duric, P. Littrup
Detection of brachytherapy seeds using ultrasound radio frequency signals [6147-19]
X. Wen, S. Salcudean, P. Lawrence
Investigation of foreign objects in soft-tissue using a PE-CMOS ultrasound system: a preliminarycomparative study [6147-20]
C. Liu, S. Lo, M. Freedman, M. Lasser, B. Lasser, J. Kula, Y. Wang, T. Hsieh, A. Sarcone
Image stitching for three-pass whole breast ultrasound [6147-21]
R. Chang, C. Chen, E. Takada, Y. Chou, D. Chen
CARDIAC IMAGING
A scalable beamforming architecture for real-time 3D ultrasonic imaging using nonuniform sampling[6147-22]
O. Dandekar, C. Castro-Pareja, R. Shekhar
Three-dimensional segmentation of the heart muscle using image statistics [6147-23]
M. Nillesen, R. Lopata, I. Gerrits, L. Kapusta, H. Huisman, J. Thijssen, C. de Korte
Electric current mapping using the acousto-electric effect [6147-24]
R. Olafsson, R. Witte, K. Kim, S. Ashkenazi, M. O'Donnell
Toward real-time endocardial boundary detection from intracardiac echocardiographic images: acomparative study [6147-25]
Y. Ganji, F. Janabi-Sharifi, S. Safavi-Naeini
Novel spatiotemporal voxel interpolation with multibeat fusion for 3D echocardiography with irregulardata distribution [6147-26]
J. Bosch, M. van Stralen, M. Voormolen, B. Krenning, C. Lancée, J. Reiber, A. van der Steen, N. de Jong
Development of a high frame rate ultrasonic system for cardiac imaging in small animals [6147-27]
L. Sun, J. Cannata, J. Johnson, J. Yen, C. Feng, K. Shung
POSTER SESSION
Fully sampled 3600 element two dimensional transducer array for low cost C-scan imaging [6147-28]
M. Eames, S. Zhou, J. Hossack
Ultrasound image deconvolution in symmetrical mirror wavelet bases [6147-29]
W. Yeoh, C. Zhang, M. Chen, M. Yan
Plane wave fast color flow mode imaging: a parameter study [6147-30]
I. Bolic, J. Udesen, F. Gran, J. Jensen
Superresolution spatial compounding techniques with application to 3D breast ultrasound imaging[6147-31]
P. Soler, G. Delso, N. Villain, E. Angelini, I. Bloch
Coded excitation with sigma-delta sampling for medical ultrasound imaging [6147-32]
Y. Yoo, J. Cao, L. Koh, Y. Kim
Freehand ultrasound calibration using the unscented Kalman filter [6147-33]
M. Moghari, T. Chen, P. Abolmaesumi
Functional and morphological ultrasonic biomicroscopy for tissue engineers [6147-34]
S. Mallidi, S. Aglyamov, A. Karpiouk, S. Park, S. Emelianov
Tissue imaging utilizing the ultrasonic vibration potential [6147-35]
S. Wang, C. Nguyen, S. Li, T. Hamilton, V. Gusev, G. Diebold