    Records essential navigational status,Helps locate casualty causes an

    Data Collecting Unit

    Data Recording Unit

    B r i d

    The VR-5000 is a Voyage Data Recorder (VDR)designed to meet IMO A.861 (20) and IEC 61996regulations.The revised SOLAS Chapter V requires the installation ofa VDR on passenger ships of 150 GT and above, also onother ships of 3000 GT and above on internationalvoyages for new building on and after 1 July, 2002.The purpose of the VDR is to help investigators locatecauses of marine casualty and promote education forsafe navigation.

    The VR-5000 consists of a Data Collecting Unit (DCU)and a Data Recording Unit (DRU). The DCU containsinterface modules, a powerful computer and a statusmonitor. It collects data from sensors as required by theIMO and IEC standards. The DCU processes theincoming data and information in the order of occurrence,while old data is overwritten with new data for storage inthe DRU.The recording time is a minimum 12 h with thestandard flash memory. In case of an emergency supply

    failure, the dedicated reserve batteries enable the VDR torecord bridge audio for 2 h. The DCU can be fitted witha Hot Swap HD for storage and retrieval of voyagedata for periods up to several weeks. The hot swapsystem and an external docking station for the HD allowsdata to be retrieved without interrupting the mandatorydata collection.

    The Data Recording Unit (DRU) stores the data comingfrom the DCU in the flash memory. All essentialnavigation and status data including bridge conversation,VHF communications and radar images are recorded.The data can be retrieved by using the playback softwarefor both accident investigation or educational briefingpurposes. The DRU components are embodied in aprotective capsule. The capsule ensures survivaland recovery of the recorded data afteran incident. An acoustic pinger helpslocate the capsule.

    Reliable and fast data exchange betweendata collecting and data recording unitsvia a single IEEE1394 cableEasy commissioning and maintenance byPC downloading/uploading12-hour recording of normal sensor storedin standard memoryUTC time tagged for systemsynchronization and easy data retrievalChoice of flash memory capacity in thedata recording unit

    Expansion for more sensors viainexpensive junction boxComplies with IMO A.861(20), IEC 61996,IEC 60945Expandable flash memory capacity in DRUfor storage of data beyond mandatoryrequirementsHot Swap HD for storage and retrieval ofdata for longer periods

    Implementation schedule (International voyages)1. passenger ships NB: 1 July 2002;2. ro-ro passenger ships constructed before

    1 July 2002: before first survey after 1 July 2002;3. passenger ships other than ro-ro constructed

    before 1 July 2002: before 1 January 2004; and4. NB other than passenger ships, of 3,000 gross

    tonnage+ : 1 July 2002.

  • 8/12/2019 VR5000

    3/4

    command and control of ship.promote education for safe navigation.

    P l a y b a c

    k D a t a

    Commercial PCwith playback software

    Data to be recorded

    RADARSFR-15X5 MK3

    FR-21X5 SeriesFAR-28x5 Series

    GPS NavigatorGP-80

    Echo SounderFE-700

    Doppler Speed LogDS-50

    VHF R/T FM-8500

    c o n v e r s a t i o n /A l a r m

    s

    V H F A u

    d i o

    n s o r D a t a

    R a d a

    r I m a g

    e s

    Date and timeOS positionSpeedHeadingBridge audioCommunication audio (VHF)Radar imagesEcho SounderMain alarms (IMO mandatoryalarms)Rudder order and responseEngine order and responseHull openings (doors) status

    Watertight and fire doors statusAccelerations and hull stresses*Wind speed and direction**Shall be recorded if available

    P O S N ,

    C O G , S

    O G , e t c

    Microphone6 mics standard

  • 8/12/2019 VR5000

    4/4

    GENERALRules and Regulations

    IMO A.861(20), IEC 61996, IEC 60945, IEC 61162Data Collecting Unit (DCU)Structure of DCU

    Deck mounted, containing a status display, interface,

    mainframe computer, dedicated reserve battery, power supplyfor all VDR operationInterface

    Fire wire (IEEE1394) 1 chDigital interface IEC 61162: 8 channelsEthernet: 1 ch 10/100 Base-TAnalog: 16 portsContact: 12 portsDigital status (5-32 V): 52 portsBridge communication: 2 ch (max 6 ch)VHF audio: 2 portsRadar RGBHV (VGA to SXGA): 1 ch (max 4)

    Integrity monitoring

    Alarms for mains supply failure, recording function, bit errorrate, mic functionData retrieval

    Data stored in the CPU in the DCU may be copied for lessonor investigation with an optional software. Interruption of datastorage to DRU is less than 8 minutes.

    Data Recording Unit (DRU)Memory

    6 GB flash memory standard for IMO mandatory data for12 h cycle, first-in first-out basis. Retains data for more than10 years under no external powerOptional: Larger memory for extended duty cycle

    ENVIRONMENTAL TESTS (for protective capsule)Fire: 1100C for 1 h, 260C for 10 h

    (complies with ED 56A)Shock: 50 G, duration 11 msPenetration: 250 kg with a pin 100 mm dropped

    from 3 m (ED 56A)Deep sea immersion: 6,000 mAcoustic Pinger: Pinger emitting 10 ms pulses at37.5 kHz. Automatically switched on

    when submerged in water.Data retrieval: By playback equipment (not part of

    standard VR-5000)POWER SUPPLY115 - 230 VAC, 50 - 60 HzEQUIPMENT LISTStandard1. Data Collecting Unit (including Junction Box) 1 unit2. Data Recording Unit with 30 m cable and cradle 1 unit3. Microphone 6 sets4. Installation Materials and Spare Parts 1 unitOptional1. Junction Box2. Remote Status Display3. Removable Hard Disk Drive

    With the standard DRU, up to two radars can be connected. For further details,please contact local dealer and agent.

    6 0 0 2 3

    . 6 "

    5 2 3 2 0

    . 6 "

    6 5 0 2 5

    . 6 "

    5 2 3 ( D o o r

    O p e n

    i n g

    )

    590 23.3" 600 23.6"

    1405.5"

    100 3.9"502.0"

    2 4 2

    1 7 2

    510 21.1"

    491.9"142 0.5"

    160 6.3"200 7.9"

    176 6.9"

    1 6 0 6

    . 3 "

    240 9.5"

    190 7.5"4- 8.5

    56 2.2"

    SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

    Data Recording Unit

    Data Collecting Unit

    SPECIFICATIONS OF VR-5000

    02093N Printed in JapanFURUNO U.S.A., INC.Camas, Washington, U.S.A.Phone: +1 360-834-9300 Telefax: +1 360-834-9400FURUNO (UK) LIMITEDDenmead, Hampshire, U.K.Phone: +44 2392-230303 Telefax: +44 2392-230101FURUNO FRANCE S.A.Bordeaux-M rignac, FrancePhone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01FURUNO ESPANA S.A.Madrid, SpainPhone: +34 91-725-90-88 Telefax: +34 91-725-98-97

    FURUNO DANMARK ASHvidovre, DenmarkPhone: +45 36 77 45 00 Telefax: +45 36 77 45 01FURUNO NORGE A/Slesund, NorwayPhone: +47 70 102950 Telefax: +47 70 127021FURUNO SVERIGE ABVstra Fr lunda, SwedenPhone: +46 31-7098940 Telefax: +46 31-497093FURUNO SUOMI OYHelsinki, FinlandPhone: +358 9 341 7570 Telefax: +358 9 341 5716

    Weight: 25 kg, 55.0 lb

    Weight: 65 kg, 143 lb

    115/230 VAC

    OptionalJunction Box

    24 VDC

    GPSSpeed logHeading device(Gyro Compass, etc.)Echo sounderAuto pilotEngine telegraphSteering gearM/E remote systemMain air compBow thrustersShell door systemWatertight doorsFire doorsAnemometerFire detectionMain alarms systemRadarMicrophoneVHF etc.

    12 ch Contact Closure52 ch Digital Input

    Ethernet10/100 Base-T

    I E E E 1 3 9 4

    3 0 m

    8 ch (optional extra 8 ch)IEC 61162

    16 ch

    Analog

    Ethernet

    10/100 Base-T

    1 ch(optional extraup to 3 ch)

    R/G/B/H/V

    PC for playbackor programming

    6 chBridge Audio

    VHF

    Analog

    ContactIEC 61162

    RemoteStatus Display2 ch

    Option

    RS-232C