VS1SD
Analog I/O Jumper Settings
Control Circuit Board
Rel
ay o
utp
uts
Type Function Internal supply
Activehigh
JP6
JP1
J1 J2 J3
P3
JP3
JP3
JP2
ENP
ENP
EPN
EPN
EPN
EPN
EPN
DFT
DFT
DFT
DFT
DFT
INP
INP
INP
INP
INP
ENP
ENP
ENP
JP6
120 ohmtermination
No termination
JP5
JP5
JP5
JP5
JP5
JP6 JP6
JP6Factory
settings as shown
Note:Relay outputs are
rated at 10-30 VDC or 240 VAC @ 5 A resistive
(non-inductive).
Digital input connections shown when using factory
default jumper settings
1
1
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Load
Load
Load
P1503 P1504
Load
Rel
ay O
ut 1
N.C
.
Ena
ble
0-10
VD
C
Dig
. Inp
ut 1
Analog GND
Analog input 1
Pot. reference
Analog input +2
Analog output 1*
Analog output 2*
*Referenced to J1-1
Analog input -2P1408
P1510, P1511, P1512
P1513, P1514, P1515
Dig
. Inp
ut 2
Dig
. Inp
ut 3
Dig
. Inp
ut 4
Dig
. Inp
ut 5
Dig
. Inp
ut 6
Dig
. Inp
ut 7
Dig
. Inp
ut 8
Rel
ay O
ut 1
CO
M
Rel
ay O
ut 2
CO
M
Rel
ay O
ut 1
N.O
.
Rel
ay O
ut 2
N.O
.
Rel
ay O
ut 1
N.C
.
232425 26 27 28 29 30
P1
Fault
USBUSB port
1
1
1
1
RS485
S G A B S
1
1
Activelow
External supply
ANAIN2JP1
ANAOUT1JP2
Voltage
Current
CommunicationsTermination jumper
Digital Outputs
Co
ntro
l Bo
ard
Co
ntro
l Bo
ard
Sourcing Current Connections Sinking Current Connections
Note: Digital outputs are rated at 24 VDC @ 60 mA resistive (non-inductive).
J2 J2
P1501Out 1
P1501Out 1P1502
Out 2P1502Out 2
J3 J3
Dig
ital o
utp
ut 1
+ (C
olle
cto
r)
Dig
ital o
utp
ut 1
+ (C
olle
cto
r)
Dig
ital o
utp
ut 2
+ (C
olle
cto
r)
Dig
ital o
utp
ut 2
+ (C
olle
cto
r)
Dig
ital o
utp
ut 1
- (E
mitt
er)
Dig
ital o
utp
ut 1
- (E
mitt
er)
Dig
ital o
utp
ut 2
- (E
mitt
er)
Dig
ital o
utp
ut 2
- (E
mitt
er)
Ext
erna
l Use
r R
etur
n
Ext
erna
l Use
r R
etur
n
Ext
erna
l Use
r +
24 V
Ext
erna
l Use
r +
24 V
Inte
rnal
+24
V
Inte
rnal
+24
V
Inte
rnal
24
V R
etur
n
Inte
rnal
24
V R
etur
n
17 1718 1819 1920 2021 2122 2223 2324 24
Note: Optional equipment such as input/output reactors/filters are not shown. See instruction manual MN766.
Note: See instruction manual MN766 for important information regarding motor power wiring and output reactors.
Thermostat and control leads must be in separate conduits.
Frame Size AA 1-Phase Input Drives Frame Size AA 3-Phase Input Drives
Frame Size B and C Drives Frame Size D Drives
L1 L2 N GND R1/B+
R2 B- T1 T2 T3 TH1 TH2 GND L1 L2 L3 GND R1/B+
R2 B- T1 T2 T3 TH1 TH2 GND
L1 L2 L3 B+/R1
R2 B- T1 T2 T3 TH1 TH2 GND L1 L2 L3 T1 T2 T3R+/R1 R2 B-
MotorChassisGround
MotorChassisGround
TH1 TH2 GND
Keypad Components
The keypad is used to program the control parameters, to operate the motor and to monitor the status and outputs of the control by accessing the display options, the diagnostic menus and the fault log. Additionally, drive parameters can be stored in the keypad for future retrieval.
Display Features
Speed Reference
Defines action of F2 keyDefines action of F1 key
Local RemotePresent Menu SelectionStop – Forward – Reverse
Indicator Lights:(On when indicated Key is active)
FWD & REV: Green light indicator.
STOP: Red light indicator
JOG: Jog Speed Selected Green light indicator
Display Diagnostics –I/O StatusI/O Function configurationModified ParametersControl Operation DataCustom UnitsFault Display – 10 Faults with Time Stamp
F2 – Clears faults or undo parameter edit changes or function indicated by text displayed directly above key.
Up Arrow Left Arrow Down Arrow Right Arrow
Moves cursor to select menu choices.
LOCAL/REMOTE – Switches between local and remote modes.
HELP – Provides help at each display screen, setup parameter and fault. Press to view/close help information.
JOG – Initiates Jog mode. Press FWD or REV for motion. Only in local mode.
FWD – When pressed, initiates a forward direction run command.
Indicator Lights – (on indicated key)STOP key with red light indicator.FWD key with green light indicator.REV key with green light indicator.JOG key with green light indicator.
Keypad Display – Displays status Information during Local or Remote operation. It also displays information during parameter setup and fault or Diagnostic information.
F1 – Alternates or "toggles" between the last two menu choices or function indicated by text displayed directly above key.
ENTER – Press ENTER to save parameter value changes. In the display mode the ENTER key is used to directly set the local speed reference. It is also used to select other operations when prompted by the keypad display.
MENU/ESC – Selects the menu display when viewing status. The following menu items are shown: Status, Basic Params, Advanced Prog, Event Log, Diagnostics and Display Options. Backs up one level for other screens.
REV – When pressed, initiates a reverse direction run command.
STOP – Initates a stop command.
Note: Pressing the stop key twice in succession will immediately disable the top drive placing the motor in a coast stop condition.
STATUS FWD LOCAL
159.5V 600RPM6.2A 20.0HZ
DIAG 600R MAIN
Digital Input Jumper Settings
Please consult the VS1SD Installation and Operation Manual, MN766, before operating the drive. Also, please read the precautionary and warning statements in the Safety Notice, Paragraph 1.2, in MN766.
AC Input power
PE
StarPoint
See instruction manual MN766
Fuses
AC
Inp
ut
Dyn
amic
Bra
ke
SH
IELD
STATUS BASIC PARAMS ADVANCED PROG EVENT LOG DIAGNOSTICS
STATUS BACK
STATUS BASIC PARAMS ADVANCED PROG EVENT LOG DIAGNOSTICS
STATUS BACK
LEVEL 1 BLOCKS LEVEL 2 BLOCKS LEVEL 3 BLOCKS MODIFIED PARAMS LINEAR LIST
STATUS BACK
BASIC PARAMS
LEVEL 2 BLOCKS
ADVANCED PROG
Auto Tuning Procedure
For PM Closed Loop Control Type:
1) Press MENU.Scroll to BASIC PARAMS.Press ENTER.
At this point the display shows CONTROL TYPE F1601,– the default value is "PM Closed Loop" – press DOWN arrow to continue tuning.
2) PM MOTOR TYPE - Default value is Int PM. Press DOWN arrow to continune or press ENTER then UP or DOWN to change MOTOR TYPE to SURFACE PM - press ENTER to select then DOWN arrow to continue.
3) Enter values from the motor nameplate for each of the following "MOTOR DATA" parameters. Press ENTER to begin editing – after each value is programmed, press ENTER then DOWN arrow for the next item.• MOTOR RATED VOLT• MOTOR RATED AMPS• MOTOR RATED SPD• MOTOR RATED FREQ
4) FEEDBACK SOURCE – (Standard VS1SD drives factory setting is "Daughter FDBK") – press DOWN arrow.
5) ENCODER COUNTS – Press DOWN arrow to skip this parameter to continue. Note: Contact Baldor if an encoder must be used for your application.
6) Scroll to CALC MOTOR MODEL – press ENTER – select YES – press ENTER.
7) After CALC MOTOR MODEL is complete, press F2 to exit MOTOR DATA and BASIC PARAMS to return to the menu.
8) ENABLE DRIVE, (Close J2-8 – J3-24 circuit).
9) Scroll to ADVANCED PROG – press ENTER.
10) Scroll to LEVEL 2 BLOCKS – press ENTER
(Note: Procedure requires that load be decoupled from motor shaft. See details below if this is not possible.
11) Scroll to AUTO TUNE – press ENTER
12) Skip ANA OFFSET TRIM – Scroll to ONE-STEP TUNING – press ENTER – select Yes – press ENTER. The ONE-STEP TUNING will take approx. 3-4 minutes to complete.
13) After the static portion of AUTO TUNE is complete, the display will alternately show STATIC TEST DONE – ROTARY FOLLOW and PRESS ENTER FOR FEEDBACK ALIGN. Select one of the following:
a) if the motor is coupled to the load, press F2 to exit AUTO TUNING
b) If the motor is not coupled to the load, press ENTER to begin rotation tuning. The first test is "FEEDBACK ALIGN" – press ENTER.
14) After "FEEDBACK ALIGN" TEST PASSED – press ENTER for "FLUX CUR TUNE".
15) After "FLUX CUR TUNE" TEST PASSED – press ENTER for "SPD LOOP TUNE".
16) After "SPD LOOP TUNE" TEST PASSED – press ENTER for "END OF TEST".
17) Press F2 to return to the MENU – press F1 to return to the STATUS display.
18) It may be possible to improve the speed loop after the motor is coupled to the load by manual tuning of the Speed Prop Gain (P1635), Speed Int Gain (P1636) and Speed Diff Gain (P1637).
Note: It is not recommended to perform SPEED LOOP Autotune while the load is coupled to the motor.
BASIC MOTOR CONTROL
CONTROL TYPEPM Closed Loop
STATUS F1601T1 BACK
BASIC MOTOR CONTROL
MOTOR RATED VOLT230.0 V
STATUS F2401T1 BACK
BASIC MOTOR DATA
FEEDBACK SOURCEDaughter FDBK
STATUS F2409T1 BACK
BASIC MOTOR DATA
ENCODER COUNTS1024 PPR
STATUS F2408T1 BACK
MS766 Jan. 2012
BASIC MOTOR CONTROL
PM MOTOR TYPEInt PM
STATUS F1677T1 BACK
BASIC MOTOR CONTROL
PM MOTOR TYPESurface PM
STATUS F1677T1 BACK
BASIC MOTOR DATA
CALC MOTOR MODEL YES
STATUS F2414T1 BACK
PROG AUTO TUNE
ONE-STEP TUNINGYes
BASIC F2902 BACK