Data Sync Engineering P.O. Box 539, 2 Footbridge Lane Blairstown, New Jersey 07825 TEL: (908) 362-6299 FAX: (908) 362-5889 www.datasynceng.com Copyright © 2009 Data Sync Engineering. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Wallbox Adapter Wallbox Adapter For Rowe CD51 and CD100 jukeboxes SUPPORTED WALLBOXES The model WB-CD100 adapter allows you to connect vintage wallboxes to your Rowe CD jukebox. Works with any jukebox that uses the "408322xx" Central Control Computer. This includes models CD51, CD100 and CD100A through CD100J. Regardless of the wallboxes' letter and number layout, the displayed title strips are in the sequential order of the selected songs from the CD's. You can choose to pick the first 1, 2, 10 or 20 tracks from each consecutive CD for wallbox selections. Several of the same model type wallboxes can be connected to the wallbox adapter. If you want to add mixed wallbox types, or reduce the number of wallboxes on a single port, you can purchase individual "wallbox servers" which plug in to the WB-CD100. The WB-CD100 will not interfere with connected CD Wallboxes. It is assigned to operate through the optional "REMOTE" channel. To allow wallbox selections, you will need to enable this channel. To do this ... Move service switch to "SERVICE". Enter 91, "RMT SELECT" will appear. While holding down RESET, press 9 until "ON" is displayed. Press POPULAR then move switch to "NORM". To view the accumulated number of wallbox selections, move service switch to "SERVICE". Enter 99. AMI W-40 AMI W-80 AMI W-120 AMI WQ-200 Rock-Ola 500 Rock-Ola 503 Rock-Ola 1555 Rock-Ola 1558 Rowe WRA Rowe WRB Rowe WRC Seeburg 3W1 Seeburg 3W100 Seeburg 3WA Seeburg SC1-4 Seeburg SCH1-4 Wurlitzer 3020 Wurlitzer 5207 Wurlitzer 5210 Wurlitzer 5220 Wurlitzer 5225 Wurlitzer 5250 FIRST EVER !!! Connects vintage wallboxes to your Rowe CD jukebox. LED INDICATOR Shows wallbox & RoweLink activity.

Upload: others

Post on 15-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Data Sync Engineering P.O. Box 539, 2 Footbridge Lane Blairstown, New Jersey 07825

TEL: (908) 362-6299 FAX: (908) 362-5889

www.datasynceng.com

Copyright © 2009 Data Sync Engineering. All Rights Reserved. Designated trademarks and brands are the property of their respective owners.

Wallbox AdapterWallbox Adapter For Rowe CD51 and CD100 jukeboxes

SUPPORTED WALLBOXES

The model WB-CD100 adapter allows you to connect vintage wallboxes to your Rowe CD jukebox. Works with any jukebox that uses the "408322xx" Central Control Computer. This includes models CD51, CD100 and CD100A through CD100J. Regardless of the wallboxes' letter and number layout, the displayed title strips are in the sequential order of the selected songs from the CD's. You can choose to pick the first 1, 2, 10 or 20 tracks from each consecutive CD for wallbox selections. Several of the same model type wallboxes can be connected to the wallbox adapter. If you want to add mixed wallbox types, or reduce the number of wallboxes on a single port, you can purchase individual "wallbox servers" which plug in to the WB-CD100. The WB-CD100 will not interfere with connected CD Wallboxes. It is assigned to operate through the optional "REMOTE" channel. To allow wallbox selections, you will need to enable this channel. To do this ...

Move service switch to "SERVICE". Enter 91, "RMT SELECT" will appear. While holding down RESET, press 9 until "ON" is displayed. Press POPULAR then move switch to "NORM".

To view the accumulated number of wallbox selections, move service switch to "SERVICE". Enter 99.

• AMI W-40 • AMI W-80 • AMI W-120 • AMI WQ-200 • Rock-Ola 500 • Rock-Ola 503 • Rock-Ola 1555 • Rock-Ola 1558 • Rowe WRA • Rowe WRB • Rowe WRC

• Seeburg 3W1 • Seeburg 3W100 • Seeburg 3WA • Seeburg SC1-4 • Seeburg SCH1-4 • Wurlitzer 3020 • Wurlitzer 5207 • Wurlitzer 5210 • Wurlitzer 5220 • Wurlitzer 5225 • Wurlitzer 5250

FIRST EVER !!! Connects vintage wallboxes to your Rowe CD jukebox.

LED INDICATOR Shows wallbox & RoweLink activity.

Page 2: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

CO

M

(YELLOW)

25V

AC

SIG

(YELLOW)

WA

LL

BO

X S

EL

EC

TO

R

Bla

ck w

ire

is n

ot

use

d.

Ap

ply

tap

e o

r w

ire

nu

t.

WA

LL

BO

X P

OW

ER

In-li

ne

fuse

ho

lder

w

ith 1

A f

use

PO

WE

R T

RA

NS

FO

RM

ER

25

-30

VA

C, 2

Am

ps

Rad

io S

hac

k 27

3-15

12

or

equ

ival

ent

NO

T S

UP

PL

IED

B

ut r

equ

ired

to

po

wer

wal

lbo

x

3-P

IN D

ATA

LIN

K C

ON

NE

CTO

R

Co

nn

ects

to

on

e o

r m

ore

"S

erve

r U

nit

s" t

o e

xpan

d w

allb

ox

cap

acit

y.

(30+

mix

ed o

r sa

me

WB

typ

es)

SW

ITC

HE

S 1

2 3

4

Sel

ects

wal

lbo

x ty

pe

WA

LL

BO

X A

DA

PT

ER

F

or

Ro

we

CD

51 &

CD

100

juke

bo

xes

usi

ng

the

"408

322x

x" C

CC

Data

Sync

Engin

eering

©

2009

All

Rig

hts

Res

erve

d

22A

WG

dis

tan

ce o

f u

p t

o 2,

000

feet

(60

9.6

met

ers)

JU

KE

BO

X C

AB

LE

CO

NN

EC

TO

R

At t

he ju

kebo

x en

d, th

e 6

-pin

co

nn

ecto

r p

lug

s in

to P

1, P

2, P

3 o

r P

4 o

n t

he

Cen

tral

Co

ntr

ol C

om

pu

ter.

Th

e 3

-pin

co

nn

ecto

r g

oes

to P

10, P

11 o

r P

12.

WB-

CD10

0

S

WIT

CH

OP

TIO

NS

O

FF

O

N

5 60

Hz

Pow

er li

ne fr

eque

ncy

(US

A)

50H

z P

ower

line

freq

uenc

y

6 M

aste

r co

ntro

ller

Ser

ver

un

it (d

ata

link

acce

ss)

7 8

NU

MB

ER

OF

SO

NG

S T

O U

SE

FR

OM

EA

CH

CD

S

elec

ts 1

, 2, 1

0 or

20

trac

ks fr

om e

ach

cons

ecut

ive

CD

, sta

rtin

g w

ith C

D n

umbe

r "0

1"

(See

"C

onfig

urat

ion

Sw

itche

s" fo

r det

ails

)

Page 3: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

1 8 7 6 5 4 3 2 O N

O F F

CONFIGURATION SWITCHES

1 2 3 4 WALLBOX MODEL Max Sel Seq

OFF OFF OFF OFF Rock-Ola 500, 1555, 1558 (and most other models) 200 Page

OFF OFF OFF ON Seeburg Consolette SC1/2/3/4, SCH1/2/3/4 160 Letter

OFF OFF ON OFF Wurlitzer 5210, 5220, 5250 200 Number

OFF OFF ON ON Seeburg Wall-O-Matic 3W1, 3W100 100 Number

OFF ON OFF OFF Seeburg Wall-O-Matic 3WA 200 Letter

OFF ON OFF ON Rowe WRA, WRB, WRC 200 Letter

OFF ON ON OFF AMI W-40, W-80, W-120, WQ200 200 Page

OFF ON ON ON Wurlitzer 5207 104 Button

ON OFF OFF OFF Wurlitzer 5225 100 Number

ON OFF OFF ON Wurlitzer 3020 24 Button

ON OFF ON OFF Rowe WRA, WRB, WRC (Translated to "200/Number" format) 200 Letter

ON OFF ON ON Alternate Rowe WRA, WRB, WRC 200 Letter

ON ON OFF OFF Alternate Seeburg Wall-O-Matic 3W1, 3W100 100 Number

ON ON OFF ON Alternate Wurlitzer 5225 100 Number

ON ON ON OFF "Test Mode" Plays selection # 005 on any wallbox voltage signal

ON ON ON ON Factory use only

5 AC POWER FREQUENCY

OFF 60Hz (USA)

ON 50Hz

6 UNIT SELECT

OFF Master controller

ON Server unit (multiple servers issue song requests to the master)

WALLBOX ADAPTER TEST

Set wallbox model to "Test Mode", touch a 9 -volt battery to the adapters' wallbox wires. Song # 005 should play.

7 8 NUMBER OF TRACKS FROM EACH CD (Starting disc #1)

OFF OFF 1 (First track from each consecutive CD)

OFF ON 2 (First two tracks from each consecutive CD)

ON OFF 10 (First ten tracks from each consecutive CD)

ON ON 20 (First twenty tracks from each consecutive CD)

Page 4: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

NBR LTR SEL

A1 A2 A3 A4 A5 A6 A7 A8 A9 A0

B1 B2 B3 B4 B5 B6 B7 B8 B9 B0

C1 C2 C3 C4 C5 C6 C7 C8 C9 C0

D1 D2 D3 D4 D5 D6 D7 D8 D9 D0

E1 E2 E3 E4 E5 E6 E7 E8 E9 E0

A1 B1 C1 D1 E1 F1 G1 H1 J1 K1

L1 M1 N1 P1 Q1 R1 S1 T1 U1 V1

A2 B2 C2 D2 E2 F2 G2 H2 J2 K2

L2 M2 N2 P2 Q2 R2 S2 T2 U2 V2

A3 B3 C3 D3 E3 F3 G3 H3 J3 K3

001 002 003 004 005 006 007 008 009 010

011 012 013 014 015 016 017 018 019 020

021 022 023 024 025 026 027 028 029 030

031 032 033 034 035 036 037 038 039 040

041 042 043 044 045 046 047 048 049 050

NBR LTR SEL

F1 F2 F3 F4 F5 F6 F7 F8 F9 F0

G1 G2 G3 G4 G5 G6 G7 G8 G9 G0

H1 H2 H3 H4 H5 H6 H7 H8 H9 H0

J1 J2 J3 J4 J5 J6 J7 J8 J9 J0

K1 K2 K3 K4 K5 K6 K7 K8 K9 K0

L3 M3 N3 P3 Q3 R3 S3 T3 U3 V3

A4 B4 C4 D4 E4 F4 G4 H4 J4 K4

L4 M4 N4 P4 Q4 R4 S4 T4 U4 V4

A5 B5 C5 D5 E5 F5 G5 H5 J5 K5

L5 M5 N5 P5 Q5 R5 S5 T5 U5 V5

051 052 053 054 055 056 057 058 059 060

061 062 063 064 065 066 067 068 069 070

071 072 073 074 075 076 077 078 079 080

081 082 083 084 085 086 087 088 089 090

091 092 093 094 095 096 097 098 099 100

NBR LTR SEL

L1 L2 L3 L4 L5 L6 L7 L8 L9 L0

M1 M2 M3 M4 M5 M6 M7 M8 M9 M0

N1 N2 N3 N4 N5 N6 N7 N8 N9 N0

P1 P2 P3 P4 P5 P6 P7 P8 P9 P0

Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q0

A6 B6 C6 D6 E6 F6 G6 H6 J6 K6

L6 M6 N6 P6 Q6 R6 S6 T6 U6 V6

A7 B7 C7 D7 E7 F7 G7 H7 J7 K7

L7 M7 N7 P7 Q7 R7 S7 T7 U7 V7

A8 B8 C8 D8 E8 F8 G8 H8 J8 K8

101 102 103 104 105 106 107 108 109 110

111 112 113 114 115 116 117 118 119 120

121 122 123 124 125 126 127 128 129 130

131 132 133 134 135 136 137 138 139 140

141 142 143 144 145 146 147 148 149 150

NBR LTR SEL

R1 R2 R3 R4 R5 R6 R7 R8 R9 R0

S1 S2 S3 S4 S5 S6 S7 S8 S9 S0

T1 T2 T3 T4 T5 T6 T7 T8 T9 T0

U1 U2 U3 U4 U5 U6 U7 U8 U9 U0

V1 V2 V3 V4 V5 V6 V7 V8 V9 V0

L8 M8 N8 P8 Q8 R8 S8 T8 U8 V8

A9 B9 C9 D9 E9 F9 G9 H9 J9 K9

L9 M9 N9 P9 Q9 R9 S9 T9 U9 V9

A0 B0 C0 D0 E0 F0 G0 H0 J0 K0

L0 M0 N0 P0 Q0 R0 S0 T0 U0 V0

151 152 153 154 155 156 157 158 159 160

161 162 163 164 165 166 167 168 169 170

171 172 173 174 175 176 177 178 179 180

181 182 183 184 185 186 187 188 189 190

191 192 193 194 195 196 197 198 199 200

SEQUENCED NUMBERS SEQUENCED LETTERS

SELECTION NUMBER

WALLBOX TRANSLATION CHART

Page 5: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Seeburg Wall-o-matic 3W1 / 3W100

100 select

Seeburg Wall-o-matic 3WA

200 select

COMMON 25VAC SIGNAL

SIGNAL

25VAC

COMMON

Wallbox Wiring Diagrams CAUTION: Do not attempt to hook up a wallbox power supply if you are not familiar with electrical wiring, consult with a qualified person or an electrician. Do not leave any wires exposed, always use wire-nuts or electrical tape on all connections. Improper wiring can result in a fire or shock hazard.

Page 6: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Seeburg Consolette SC1-4 / SCH1-4

160 select

Wurlitzer 5220 200 select

Wurlitzer 5225

100 select

BLK WHT BLU

COMMON 25VAC SIGNAL

25VAC COMMON SIGNAL

3 G 1

To enable coin operation, the BRN / RED / ORG terminals must be shorted together and connected to the 25VAC terminal (WHT) using a 40-50 Ohm, 10 Watt power resistor (solenoid current = 400mA).

Page 7: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Wurlitzer 5207 104 select

SIGNAL COMMON 25VAC

AMI W-40 / W-80 / W-120 40 / 80 / 120 select

COMMON

Rowe WRA / WRB / WRC 200 select

1 2 3 4

COMMON 25VAC SIGNAL 25VAC*

A wire jumper must be inserted from the 25VAC main power terminal (#2) to the 25VAC* keypad motor terminal (#4).

25VAC

SIGNAL

Page 8: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Wurlitzer 5210 200 select

SIGNAL COMMON 25VAC

Rock-Ola 1555 200 select

Rock-Ola 1558 160 select

COMMON SIGNAL 25VAC COMMON SIGNAL 25VAC

25VAC

COMMON

SIGNAL

Wurlitzer 5250 200 select

Rock-Ola 500 160 select

25VAC COMMON SIGNAL

Page 9: Wallbox Adapternbr ltr sel a1 a2 a3 a4 a5 a6 a7 a8 a9 a0 b1 b2 b3 b4 b5 b6 b7 b8 b9 b0 c1 c2 c3 c4 c5 c6 c7 c8 c9 c0 d1 d2 d3 d4 d5 d6 d7 d8 d9 d0 e1 e2 e3

Wurlitzer 3020 24 select

SIGNAL 25VAC 120VAC

This wallbox has its own “built-in” transformer and requires a 120VAC power cord. High voltage is used so be very careful when wiring up this wallbox. The wallbox adapter only requires the two wire connection to terminal #1 and terminal #3.

The Original 1015 Bubbler Wallbox

AMI WQ-200 200 select

COMMON 25VAC SIGNAL 25VAC*

A wire jumper must be inserted from the 25VAC main power terminal to the 25VAC* lock-out.

TECH NOTE Electrical pulses transmitted by the wallbox are generated by a contact arm rotating on a selector disc containing contact points. When these contacts become gummed up and corroded, the wallbox may not make the proper selection. Occasionally, these contacts require cleaning. They can be cleaned with a cloth saturated with isopropyl alcohol. Do not use emery cloth or sandpaper as this may remove the plating. On really worn wallboxes, where basic cleaning doesn’t seem to cure the problem, you may have successful results by using a low abrasive polish, such as “Scratch Out” or “Brasso”. This will make the contact surfaces shiny and smooth.