water distribution systems – part 1 1 lecture 2 dr. jawad al-rifai
TRANSCRIPT
![Page 1: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/1.jpg)
Water Distribution Water Distribution Systems – Part 1Systems – Part 1
1
Lecture 2Dr. Jawad Al-rifai
![Page 2: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/2.jpg)
ContentsContents
Methods of Distributing WaterCapacity Requirements
System Losses Population Forecast Water Demand Fire Demand Pressure Design Period Work Examples
Storage Reservoirs Elevated Reservoirs Work Example
2
![Page 3: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/3.jpg)
Water Distribution Systems (WDS)Water Distribution Systems (WDS)The objective of WDS is to deliver water to individual
consumers with appropriate quality, quantity and pressure.
The distribution system describes collectively the facilities used to supply water from its source to the point of usage.
This may include extensive system of pipes, storage reservoirs, pumps and related appurtenances.
The proper functioning of a water distribution system is critical to providing sufficient drinking water to consumers as well as providing sufficient water for fire protection
3
![Page 4: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/4.jpg)
DefinitionsDefinitions
Average day demand. The total annual quantity of water production for an agency or municipality divided by 365.
Maximum day demand. The highest water demand of the year during any 24-h period.
Peak hour demand. The highest water demand of the year during any 1-h period.
Peaking factors. The increase above average annual demand, experienced during a specified time period. Peaking factors are customarily used as multipliers of average day demand to express maximum day and peak hour demands.
Distribution pipeline or main. A smaller diameter water distribution pipeline that serves a relatively small area. Water services to individual consumers are normally placed on distribution pipelines. Distribution system pipelines are normally between 150 and 400 mm (6-16 in.).
Transmission pipeline or main. A larger-diameter pipeline, designed to transport larger quantities of water during peak demand-periods. Water services for small individual consumers are normally not placed on transmission pipelines. Transmission mains are normally pipelines larger than 400 mm (16 in.).
4
![Page 5: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/5.jpg)
Methods of Distributing WaterMethods of Distributing WaterDepending on the topography between the source and the
consumer the following may be used to transport water to consumers with adequate pressure:
Gravity – when the source is at a sufficient elevation above the consumer to produce the desired pressure. Highly economical
Pumping – Pumps are used to develop the necessary head (pressure) to distribute to consumers and storage reservoirs
Pump-Storage System- storage reservoirs are used to maintain adequate pressure during periods of high demand and emergency (fires & power failures). During low consumption, water is pumped and stored in the storage reservoir. 5
![Page 6: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/6.jpg)
Capacity RequirementsCapacity RequirementsWhen designing a water –supply
system, a major consideration is the population to be served, the fire flows needed and the proximity to the source.
Categories of water demand are given in the table and can vary from city to city or country to country.
Category
Avg Use(liters/day)/person % of Total
Residential 260 40Commercial 90 14Industrial 190 29Public 70 10Loss 50 7
660 100
Category MCM/Yr (2005) % of TotalDomestic 142 40Major Industrial 66 18Minor Industrial 11 3Irrigation 10 3Loss 128 36
357 100
Consuming Water Demand for Trinidad and Tobago (WRA)
Typical Distribution of Water Demand (Chin 2000)
6
Residential – Typical for third world- 135 lpcd
Bath – 55 LWashing Cloths – 20 LWC – 30 LWashing House – 10 LWashing Utensils – 10 LCooking – 5 LDrinking – 5 L
![Page 7: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/7.jpg)
Demand vary throughout Demand vary throughout the 24hr period and can the 24hr period and can rangerange - from 25-40% of the avg - from 25-40% of the avg daily demand between daily demand between 12.00 to 6.00am 12.00 to 6.00am - to as high as 150 to - to as high as 150 to 175% during morning 175% during morning and evening peakand evening peak
Demand also vary from Demand also vary from year to year; season to year to year; season to season; day to day and season; day to day and house to househouse to house
Capacity Requirements - Water DemandCapacity Requirements - Water Demand
7
![Page 8: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/8.jpg)
The range of demand conditions expected within a distribution are specified by demand factors or peaking factors. See Table
NOTE:Max daily demand – demand on the day of the year that
uses the most water = 1.8 x Avg daily demandMax hourly demand – the demand during the hour that
uses the most water = 3.25 x avg daily demand
Capacity Requirements - Water DemandCapacity Requirements - Water Demand
8
![Page 9: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/9.jpg)
System LossesSystem LossesLeaking and overflow from reservoirLeaking from main and service pipelinesLeaking and losses on premisesLeaking from public taps
In a well maintained system losses are about 20%. Partially maintained systems are about 50%
9
![Page 10: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/10.jpg)
Capacity Requirements –Capacity Requirements –
In water-supply projects the water demand at the end of the design life of the project forms the basis for design.
Design flow rate =population (at the end of service life) x per capita water demand
10
![Page 11: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/11.jpg)
11
![Page 12: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/12.jpg)
Design PeriodsDesign PeriodsDesign period: Time periods for which the system
or components is to be adequate (useful life)The design periods of water & wastewater
facilities depends on several factors including :◦Point of diminishing returns:
(Repair and maintenance vs cost of new facility)◦Ease of replacement and expansion◦Likelihood of obsolescence by technological
advances◦Future needs (expected growth)◦Cost and interest rate
12
![Page 13: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/13.jpg)
Design Period-Drinking Water SystemsDesign Period-Drinking Water Systems
13
(1)Allow for expansion
![Page 14: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/14.jpg)
Design Period Wastewater SystemsDesign Period Wastewater Systems
14
(1)Allow for expansion
![Page 15: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/15.jpg)
Population Projection
15
![Page 16: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/16.jpg)
16
Population Projection
![Page 17: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/17.jpg)
17
![Page 18: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/18.jpg)
18
Work Example – Population ForecastWork Example – Population Forecast
![Page 19: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/19.jpg)
19
![Page 20: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/20.jpg)
20
![Page 21: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/21.jpg)
21
![Page 22: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/22.jpg)
22
![Page 23: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/23.jpg)
Work Example –water DemandWork Example –water DemandA community have a population of 225,000
persons with the average daily demand 600L/capita/day. 1- Calculate the water demand; giving the following data◦Maximum daily demand factor is 1.8◦Max. peak hour demand factor is 2.7◦Fire demand should be calc for 10 hrs
2- Based on your calculation, Should we include a storage reservoir in our design and if yes, estimate the size of the reservoir
23
![Page 24: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/24.jpg)
Work Examples – Water DemandWork Examples – Water Demand
24
![Page 25: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/25.jpg)
Work Examples – Water DemandWork Examples – Water Demand
25
![Page 26: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/26.jpg)
Work Examples – Water DemandWork Examples – Water Demand
26
![Page 27: Water Distribution Systems – Part 1 1 Lecture 2 Dr. Jawad Al-rifai](https://reader035.vdocument.in/reader035/viewer/2022062223/5517b0e05503463e368b5f77/html5/thumbnails/27.jpg)
Work Examples – Water DemandWork Examples – Water Demand
27