wayne state university student center building
TRANSCRIPT
LOCATION MAP
LOADING DOCK
STUDENT CENTER
LIMITED LAY-DOWN AREA.DO NOT BLOCK EXIT DOORSFROM CHATSWORTH TOWER.
STAGING PLANNOTE: DO NOT PLACE HOT-TANKSWITHIN 25 FEET OF ANY BUILDING.
0' 24' 48' 96'APPROXIMATE SCALE
arc
hite
ctu
re
Sheet No.
6765 Daly RoadWest Bloomfield, Michigan 48322-4585
T 248.932.2010F 248.932.3088
DNCE Project No. 6590-00
Project number
Issue Date
Drawn by
Checked by
Seal
Student Center LoadingDock Leak Repairs
Wayne State University5221 Gullen MallDetroit, MI 48202
WSU No. 034-282276
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
Suite 555
400 Galleria Officentre
fax 248.352.1821
phone 248.352.8310
Southfield, Michigan 48034
Issue:
S000
TITLE SHEET
7877-B00
08/01/2016
SRJ
AN
BID DOCUMENTS
WAYNE STATE UNIVERSITYSTUDENT CENTER BUILDINGLOADING DOCK LEAK REPAIRS5221 GULLEN MALL DETROIT, MIWSU No. 034-282276
OWNER WAYNE STATE UNIVERSITY
5454 CASS AVENUEDETROIT, MICHIGAN 48202
STRUCTURAL ENGINEER DESAI NASR CONSULTING ENGINEERS
6765 DALY ROADWEST BLOOMFIELD, MICHIGAN 48322
ARCHITECT NEUMANN/SMITH ARCHITECTURE
400 GALLERIA OFFICENTRE, SUITE 555SOUTHFIELD, MICHIGAN 48034
Sheet ListNumber Sheet Name Issue Date Current Revision Revision Date
S000 TITLE SHEET 08/01/2016 ADDENDUM NO. 2 09.07.2016
S001 GENERAL NOTES 08/01/2016
S002 SPECIAL INSPECTION REQUIREMENTS 08/01/2016
S003 LEVEL 1 COMPOSITE PLAN 08/01/2016
SD101 LEVEL 1 DEMOLITION PLAN 08/01/2016 ADDENDUM NO. 2 09.07.2016
S101 LEVEL 1 LOADING DOCK NEW WORK PLAN 08/01/2016 ADDENDUM NO. 2 09.07.2016
S101-R STRUCTURAL REPAIR PLAN 08/01/2016 ADDENDUM NO. 2 09.07.2016
S201 SECTIONS & DETAILS 08/01/2016 ADDENDUM NO. 2 09.07.2016
S202 REPAIR DETAILS 08/01/2016
REVISIONS
ADDENDUM NO. 2 09.07.2016
4 5 6 7 8 9 10 11 12 13
L
K
H1
G
12c
NEW 4" TOPPING SLAB ON INSULATION,PROTECTION BOARD, DRAINAGE BOARD ANDWATERPROOFING, ON EXISTING STRUCTURALSLAB. REINFORCE W/ EPOXY COATED 6x6W1.4xW1.4 W.W.F. PLACED @ MID DEPTH.MATCH SLOPE OF EXISTING SLAB. PREPEXISTING SLAB TO RECEIVE WATERPROOFINGPER MANUFACTURER'S INSTRUCTIONS.
E1
S201
E3
S201
E8
S201
C6
S201 SL
OP
E D
N.
C4
S201
NEW CONCRETESTAIRS.
H3
S201
INFILL W/ 6" SLAB ON GRADE W/6x6 W2.9xW2.9 W.W.F. PLACED@ MID DEPTH ON MIN. 4"COMPACTED GRANULAR FILL
C8
S201
TYP.
H9
S201
PROVIDE CONTROL JOINTS INTOPPING SLAB ALONG EACH BEAMLINE AND @ 15'-0" O.C. MAXIMUMSPACING THROUGHOUT.
23
'-6
"2
2'-6
"2
2'-6
"
15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-6" 1'-0" 14'-6"
NEW GALV. GUARD-RAIL PER SPEC
NEW GALV. HAND-RAIL PER SPEC
0' 4' 8' 16' 32'
EXISTING GENERATORON STEEL PLATFORM.
EXISTING ELECTRICALMANHOLE.
EXISTING WATER, STEAM, AND/ OR SANITARY LINES. VERIFYALL EXISTING UTILITIES INFIELD PRIOR TO DEMOLITION
4'-0
"
3'-0"
REMOVE EXISTING PIPE BOLLARDAND ENTRY SLAB (IF PRESENT)AND REPLACE TO MATCH EXISTINGAS NECESSARY TO COMPLETEWORK AS DESCRIBED.
REMOVE EXISTING RAMPSDURING CONSTRUCTION ANDSTORE FOR DURATION OFPROJECT. REPLACE TO MATCHEXISTING ONCE CONCRETEWORK IS COMPLETED.
REMOVE EXISTING PARKING BUMPERSDURING CONSTRUCTION AND STOREFOR DURATION OF PROJECT. REPLACETO MATCH EXIST. ONCE CONCRETEWORK IS COMPLETE.
EXISTING TRASH COMPACTORAND ELECTRICAL CONNECTION.RELOCATE AS NECESSARY TOCOMPLETE CONCRETE WORK.
NOTES
1. VERIFY EXISTING SLAB ELEVATION IN FIELD. MATCH EXISTING SLOPE.
2. THE ORIGINAL FRAMING AND CONCRETE CONFIGURATAION SHOWN IS BASED ONEXISTING DRAWINGS AND LIMITED FIELD OBSERVATIONS. THE LOCATION ANDSIZE OF EXISTING ELEMENTS NEED TO BE FIELD VERIFIED IN ALL AREAS WHERETHE EXISTING STRUCTURE IS MODIFIED OR REPAIRED.
3. FIELD VERIFY ALL EXISTING COLUMN LINES, BEAM CENTER LINES, SLAB EDGES,AND OPENING SIZES AND LOCATIONS.
4. SUBMIT ALL CONSTRUCTION EQUIPMENT LOADS TO ARCH / ENGINEER PRIOR TOUSE ON SUPPORT SLAB AREA.
5. REFERENCE DRAWINGSS001 GENERAL STRUCTURAL NOTESS002 SPECIAL INSPECTION REQUIREMENTS
arc
hite
ctu
re
Sheet No.
6765 Daly RoadWest Bloomfield, Michigan 48322-4585
T 248.932.2010F 248.932.3088
DNCE Project No. 6590-00
Project number
Issue Date
Drawn by
Checked by
Seal
Student Center LoadingDock Leak Repairs
Wayne State University5221 Gullen MallDetroit, MI 48202
WSU No. 034-282276
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
Suite 555
400 Galleria Officentre
fax 248.352.1821
phone 248.352.8310
Southfield, Michigan 48034
Issue:
S101
LEVEL 1 LOADINGDOCK NEW WORK
PLAN
7877-B00
08/01/2016
Author
Checker
BID DOCUMENTS
1/8" = 1'-0"
LEVEL 1 LOADING DOCK NEW WORK PLAN
REVISIONS
ADDENDUM NO. 2 09.07.2016
4 5 6 7 8 9 10 11 12 13
L
K
H1
G
12c
15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 15'-0" 14'-6" 1'-0" 14'-6"
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX
. 2
4W
F7
6
EX
. 2
4W
F7
6
EX
. 2
4W
F9
4
EX. 8B13EX. 8B13EX. 8B13EX. 8B13EX. 8B13EX. 8B13EX. 8B13EX. 8B13
EX
. 2
4W
F1
10
EX
. 2
4W
F1
10
EX. 16B26 EX. 16B26 EX. 16B26 EX. 16B26 EX. 16B26 EX. 16B26 EX. 16WF50
EX
. 2
4W
F8
4
EX
. 2
4W
F6
8
EX
. 2
4W
F6
8
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX
. 2
4W
F1
20
EX. 16B26
BREAK UP AND REMOVE EXISTING 4"TOPPING SLAB THROUGHOUT SHADEDAREA. REMOVE EXISTING INSULATIONAND WATERPROOFING LAYERS. DO NOTDAMAGE STRUCTURAL SLAB BELOW.
REMOVE EXISTINGCONCRETE STAIRS. DO NOTDAMAGE CONCRETE WALLOR STRUCTURAL SLAB.
BREAK UP AND REMOVE EXISTING 4"TOPPING SLAB AT HIGH SIDE OF LOADINGDOCK THROUGHOUT SHADED AREA.REMOVE EXISTING INSULATION ANDWATERPROOFING LAYERS. DO NOTDAMAGE STRUCTURAL SLAB BELOW.
REMOVE EXISTING EXPANSIONJOINT COVER, IF PRESENT.
23
'-6
"2
2'-6
"2
2'-6
"
SL
OP
E D
N.
DO
NO
T C
UT
OR
DA
MA
GE
SL
AB
AT
NO
RT
H S
IDE
OF
LO
AD
ING
DO
CK
.
SAW-CUT AND REMOVE PORTIONOF SLAB-ON-GRADE BEYONDBASEMENT WALL TO ALLOW NEWWATERPROOFING TO LAP OVERBASEMENT WALL. COORD. W/WATERPROOFING REQUIREMENTS
REMOVED DAMAGEDCONCRETE COVER OVEREXISTING CONCRETE WALL
0' 4' 8' 16' 32'
EXISTING GENERATORON STEEL PLATFORM.
EXISTING ELECTRICALMANHOLE.
EXISTING WATER, STEAM, AND/ OR SANITARY LINES. VERIFYALL EXISTING UTILITIES INFIELD PRIOR TO DEMOLITION
4'-0
"
3'-0"
REMOVE EXISTING PIPE BOLLARDAND ENTRY SLAB (IF PRESENT)AND REPLACE TO MATCH EXISTINGAS NECESSARY TO COMPLETEWORK AS DESCRIBED.
REMOVE EXISTING RAMPSDURING CONSTRUCTION ANDSTORE FOR DURATION OFPROJECT. REPLACE TO MATCHEXISTING ONCE CONCRETEWORK IS COMPLETED.
REMOVE EXISTING PARKING BUMPERSDURING CONSTRUCTION AND STOREFOR DURATION OF PROJECT. REPLACETO MATCH EXIST. ONCE CONCRETEWORK IS COMPLETE.
EXISTING TRASH COMPACTORAND ELECTRICAL CONNECTION.RELOCATE AS NECESSARY TOCOMPLETE CONCRETE WORK.
NOTES:1. CORE TEST OPENING TO DETERMINE ACTUAL THICKNESS OF
TOPPING SLAB PRIOR TO BEGINNING DEMOLITION. DO NOTCORE THROUGH STRUCTURAL SLAB BELOW.
2. PROTECT EXISTING FACADE OF BUILDING AND OTHER AREASNOT INCLUDED IN DEMOLITION.
3. CONTRACTOR SHALL PROVIDE MEANS & METHODS PLANFOR WORK ON SUPPORTED STRUCTURAL SLAB INCLUDINGEQUIPMENT LOADS TO A/E FOR REVIEW PRIOR TOBEGINNING WORK. MEANS AND METHODS TO PERFORMWORK SHALL NOT COMPROMISE EXISTING STRUCTURE.
arc
hite
ctu
re
Sheet No.
6765 Daly RoadWest Bloomfield, Michigan 48322-4585
T 248.932.2010F 248.932.3088
DNCE Project No. 6590-00
Project number
Issue Date
Drawn by
Checked by
Seal
Student Center LoadingDock Leak Repairs
Wayne State University5221 Gullen MallDetroit, MI 48202
WSU No. 034-282276
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
Suite 555
400 Galleria Officentre
fax 248.352.1821
phone 248.352.8310
Southfield, Michigan 48034
Issue:
SD101
LEVEL 1 DEMOLITIONPLAN
7877-B00
08/01/2016
SRJ
AN
BID DOCUMENTS
1/8" = 1'-0"
LEVEL 1 LOADING DOCK DEMOLITION PLAN
REVISIONS
ADDENDUM NO. 2 09.07.2016
8 9 10 11 12 13
K
H1
G
12c
15'-0" 15'-0" 15'-0" 14'-6" 1'-0" 14'-6"
EX
. 2
4W
F1
20
EX
. 2
4W
F1
10
EX
. 2
4W
F1
20
EX
. 2
4W
F1
10
EX
. 2
4W
F1
20
EX
. 2
4W
F1
10
EX
. 2
4W
F1
20
EX
. 2
4W
F1
10
EX
. 2
4W
F6
8E
X. 2
4W
F7
6
EX
. 2
4W
F6
8E
X. 2
4W
F7
6
EX
. 2
4W
F8
4E
X. 2
4W
F9
4
EX. 8B13 EX. 8B13 EX. 8B13 EX. 8B13 EX. 8B13 EX. 8B13
22
'-6
"2
2'-6
"
G4
S202
G4
S202
G4
S202
G4
S202
G4
S202
EXISTING BASEMENT WALLW/ CONCRETE PIERS ATEACH COLUMN LINE
D2
S202
A A
A
A
A
A A
AA
A
B
D2
S202
OVERHEAD CONCRETEREPAIR, APPROXIMATELY3" MAX. DEPTH.
OVERHEAD CONCRETEREPAIR, APPROXIMATELY1" DEEP
D7
S202
TYP.
PARTIAL DEPTH REPAIR TO INSIDEFACE OF LOADING DOCK WALLALONG SHADED LENGTH.APPROXIMATELY 3" MAX. DEPTH.
B2
S202
EXISTING EXPOSED 10" STRUCTURALSLAB CEILING THROUGHOUT.
EXISTING BEAMS ENCLOSED INPLASTER W/ METAL LATH. TYP.
AREA BELOW LOADING DOCKCONTAINS LARGE NUMBERSOF CONDUITS AND PIPING.REVIEW IN FIELD. INCLUDE$5,000 ALLOWANCE IN BID FORREMOVAL / REPLACEMENT OFDUCTWORK AND CONDUITS.
1
2
3
4
5
6
0' 2' 4' 8' 16'
EXISTING PARTITIONWALLS. V.I.F. TYP.
NOTES:1. PLAN VIEW SHOWS UNDERSIDE OF LEVEL 1 STRUCTURE AS
VIEWED FROM LOWER LEVEL.
2. PROTECT EXISTING FINISHES AND OTHER ELEMENTS NOTINCLUDED IN REPAIR SCOPE, INCLUDING FIRE WATCHDURING WELDING OPERATIONS.
3. SIZE AND LOCATION OF REPAIR ITEMS ARE APPROXIMATE.FIELD VERIFY ALL EXISTING CONDITIONS AND QUANTITIES.
4. IDENTIFY ALL ELECTRICAL CONDUITS, LIGHTING, ANDPLUMBING TO BE DISCONNECTED AND / OR RELOCATED TOALLOW FOR WORK TO BE PERFORMED.
DESIGNATIONS:
ROUTE AND SEAL CRACKS IN UNDERSIDE OF STRUCTURALSLAB. REFER TO DETAIL D6/202
ROUTE AND SEAL CRACKS AT INSIDE FACE OF CONCRETEWALL ABOVE STRUCTURAL SLAB
A
B
1
2
3
4
5
6
PHOTO REFERENCES
SHALLOW SLAB SPALL / CRACKING
TYPICAL SLAB CRACKING
STEEL BEAM CORROSION
MODERATE SLAB SPALL / CRACKING
STEEL BEAM CORROSION (TOP FLANGE)
CONCRETE WALL / SLAB SPALL
arch
itectu
re
Sheet No.
6765 Daly RoadWest Bloomfield, Michigan 48322-4585
T 248.932.2010F 248.932.3088
DNCE Project No. 6590-00
Project number
Issue Date
Drawn by
Checked by
Seal
Student Center LoadingDock Leak Repairs
Wayne State University5221 Gullen MallDetroit, MI 48202
WSU No. 034-282276
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
Suite 555
400 Galleria Officentre
fax 248.352.1821
phone 248.352.8310
Southfield, Michigan 48034
Issue:
S101-R
STRUCTURALREPAIR PLAN
7877-B00
08/01/2016
Author
Checker
BID DOCUMENTS
1/4" = 1'-0"
ENLARGED REPAIR PLAN (LOWER LEVEL REFLECTED CEILING)
REVISIONS
ADDENDUM NO. 2 09.07.2016
EXISTING 10"STRUCTURAL SLAB
EXIST STEEL BEAM
4" THICK TOPPING SLAB,REF TO PLAN
FILTER FABRIC
2" RIGID INSULATION
DRAINAGE BOARD
PROTECTION BOARD
WATERPROOFING LAYER
COL
LOADING DOCK. VERIFYELEVATION IN FIELD. PREP SLAB TO RECEIVE
WATERPROOFING PERMANUF. INSTRUCTIONS
8
LOADING DOCK. VERIFYELEVATION IN FIELD.
/C8 S201REFER TOFOR REMAINDER OF NEWSLAB / WATERPROOFING /INSULATION SYSTEM INFO.
6"LAP NEW WATERPROOFINGLAYER OVER EXIST.
MASTIC / LIQUID MEMBRANETERMINATION
EXISTING 10" STRUCTURAL SLAB
EXIST STEEL BEAM, V.I.F.
12 12c
JOINT, V.I.F.2" EXIST.
S201
C1
EXIST. 10" STRUCTURALSLAB
EXIST. STEEL BEAMS
/C8 S201REFER TOFOR REMAINDER OF NEWSLAB / WATERPROOFING /INSULATION SYSTEM INFO.PROVIDE EXPANSION JOINTCOVER AT TOPPING SLABPER SPECS
WATERPROOFING LAYER
DRAINAGE BOARD
NEOPRENE FLASHING(2 LAYERS)
MASTIC / LIQUIDMEMBRANE
BENT SHEET METAL /ALUMINUM PROTECTION
PROTECTION BOARD
JOINT. V.I.F.2" EXIST.
FOAM ROD
6"3"
/C8 S201REFER TOFOR REMAINDER OF NEWWATERPROOFING / INSULATION SYSTEMINFO. PROVIDE EXPANSION JOINT COVERAT TOPPING SLAB PER SPECS
NEW SLAB EXIST. SLAB
1
1
COMPACTEDGRANULAR FILL.
2-#4 CONT. EPOXYCOATED.
SL
AB
(V
.I.F
.)E
XIS
T.
4" 4"
4"
. . . ...
FOR NEW FINISHREFER TOARCHITECTURALDRAWING
SEE NOTES ON PLANFOR TYP. NEW SLABCONSTRUCTION
REFER TO PLANFOR SLAB THICKNESS
T/4 OR 3/4" MIN.
REFER TO PLANFOR SLAB THICKNESS
REFER TO PLANFOR COVER
.
T
REFER TO SPECIFICATIONSFOR JOINT FILLER MATERIAL
FOR FINISH AND REQUIREDSURFACE TREATMENT REFER TOARCHITECTURAL DRAWINGSAND SPECIFICATIONS
CUT ALTERNATE STRANDS OFW.W.F. AT JOINT. REFER TOPLAN FOR REINFORCEMENT
1/8".
K
EXIST. BASEMENT WALL.
EXIST. CONCRETE PIERBEYOND
EXIST. STEEL BEAM BEYOND.
EXIST. 10" STRUCTURAL SLAB.
1'-0
"
WRAP WATERPROOFING LAYEROVER EXTERIOR SIDE OFBASEMENT WALL. PROVIDE 6" MIN.LAP W/ EXIST WATERPROOFING.
1/2" PREMOLDED JOINT.
(2) #4 CONT. EPOXY COATEDBARS
8"
1
1
SLAB ON GRADEINFILL. REF TO PLAN
/C8 S201REFER TOFOR REMAINDER OF NEWSLAB / WATERPROOFING /INSULATION SYSTEM INFO.
G
EXIST. STEEL BEAM BEYOND.
EXIST. 8" STRUCTURAL SLAB.
/C8 S201REFER TOFOR REMAINDER OF NEW SLAB /WATERPROOFING / INSULATIONSYSTEM INFO. TYP.
EXIST. 8" CONCRETEWALL. V.I.F.
EXIST. 10" STRUCTURAL SLAB. V.I.F.
4" CONCRETE COVER WALL. REINF.W/ #4 EPOXY COATED BARS @ 8"O.C. EA. WAY.
2" RIGID INSULATION ON DRAINAGEBOARD ON PROTECTION BOARD ONWATERPROOFING ADHERED TOSTRUCTURAL WALL BEHIND.
#4 EPOXY COATED DOWELS@ 1'-0" O.C.
#4 EPOXY COATED DOWELS@ 1'-0" O.C.
(1) #4 CONT. EPOXY COATED NOSINGBAR
REMOVE BOTTOM COURSES OF BRICKFACADE. WRAP WATERPROOFING LAYER 1'-0"MIN. UP THE FACE OF CMU BEHIND. ANCHORTO CMU W/ 3/8" DIAMETER TAPCON SCREWSW/ NEOPRENE WASHERS. REPLACE BRICK TOMATCH EXISTING.
1/2" PREMOLDED JOINT.
CONCRETE WASH
EXIST. BRICK ON CMU EXTERIOR WALL
EXIST. STEEL BEAM
EXIST. STEEL COLUMNBEYOND
V.I.F
.
PROVIDE WEEP HOLES TO MATCH EXISTING.
#5 @ 8" O.C. EPOXY COATEDBOTTOM BARS EA. WAY
#4 EA. WAY EPOXY COATEDNOSING BARS TYPICAL
#3 EPOXY COATED HOOKEDBARS @ 8" O.C. TYP.
#4 EA. WAY EPOXYCOATED DOWELS TOSLAB @ 8" O.C.
#4 EPOXY COATED DOWELSTO SLAB AND WALL @ 8" O.C.
6" THICK STAIR SUPPORT WALL W/ #5EPOXY COATED BARS @ 8" O.C. EA. WAY.
#4 EPOXY COATED DOWELS @ 8" O.C.
EXIST. CONCRETESTRUCTURAL SLAB
EXIST. CONCRETE WALL
EXIST. CONCRETESTRUCTURAL SLAB.
/E3 S201REFER TOFOR REMAINDER OF LOADINGDOCK INFORMATION.
V.I.F
.
EXIST.
MATCH
1 1/4" GALVANIZED STEELPIPE HAND-RAIL PER SPEC SET HAND-RAIL POSTS IN SLEEVES
IN TOPPING SLAB ONLY, GROUT INPLACE. DO NOT DAMAGEWATERPROOFING.
1'-0"
1'-0"
3'-
6"
TY
P.
21
" T
YP
.
V.I.F. MAINTAIN ACCESSTO STAIR
13
6"
EXIST. 8" STRUCTURALSLAB.
/C8 S201REFER TO FOR REMAINDER OF NEW SLAB /WATERPROOFING / INSULATIONSYSTEM INFO. TYP.
EXIST. 8" CONCRETEWALL.
EXIST. 10" STRUCTURALSLAB.
4" CONCRETE COVER WALL. REINF. W/ #4EPOXY COATED BARS @ 8" O.C. EA. WAY.
2" RIGID INSULATION ON DRAINAGE BOARD ONPROTECTION BOARD ON WATERPROOFINGADHERED TO STRUCTURAL WALL BEHIND.
#4 EPOXY COATED DOWELS@ 1'-0" O.C.
#4 EPOXY COATED DOWELS @ 1'-0" O.C.DRILL AND ADHESIVE DOWEL TO EXIST.
(2) #4 CONT. EPOXY COATED BARS
CONCRETE WASH
EXIST. STEEL BEAM
VOLCLAY WATERSTOP ORAPPROVED EQUAL
WRAP WATERPROOFING LAYER UP THE FACE OFEXIST WALL. ANCHOR TO CMU W/ 3/8" DIAMETERTAPCON SCREWS W/ NEOPRENE WASHERS.
V.I.F
.
arc
hite
ctu
re
Sheet No.
6765 Daly RoadWest Bloomfield, Michigan 48322-4585
T 248.932.2010F 248.932.3088
DNCE Project No. 6590-00
Project number
Issue Date
Drawn by
Checked by
Seal
Student Center LoadingDock Leak Repairs
Wayne State University5221 Gullen MallDetroit, MI 48202
WSU No. 034-282276
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
Suite 555
400 Galleria Officentre
fax 248.352.1821
phone 248.352.8310
Southfield, Michigan 48034
Issue:
S201
SECTIONS & DETAILS
7877-B00
08/01/2016
SRJ
AN
BID DOCUMENTS
1" = 1'-0"S201
C8 TYPICAL TOPPING SLAB 1" = 1'-0"S201
C6 TRANSITION AT NEW / EXIST. TOPPING SLAB 1" = 1'-0"S201
C4 SECTION @ EXPANSION JOINT 3" = 1'-0"S201
C1 EXPANSION JOINT DETAILS
3/4" = 1'-0"S201
H9 TRANSITION @ NEW/EXIST. SLAB 3/4" = 1'-0"S201
H7 TYP - SLAB CONTROL JOINT
3/4" = 1'-0"S201
E1 SECTION @ BASEMENT WALL 3/4" = 1'-0"S201
E3 SECTION @ LOADING DOCK 3/4" = 1'-0"S201
E8 SECTION @ EXTERIOR STAIR
3/4" = 1'-0"S201
H3 SECTION ALONG LINE 13
REVISIONS
ADDENDUM NO. 2 09.07.2016