solaymanewu.weebly.comsolaymanewu.weebly.com/.../8/3/6/4/8364220/experiment_2.docx · web...
TRANSCRIPT
EAST WEST UNIVERSITY
Course Name : Electric Circuits - I
Course Code : EEE 101 LAB
Section No : 02
Group No : 06
Experiment No : 02
Name of the
Experiment : KIRCHHOFF’S VOLTAGE AND CURRENT LAWS
Date of allocation : 03/02/2013
Date of submission : 10/02/2013
Submitted To : Mariam B. Salim
Student’s ID : 2013-1-80-022
Student’s Name : Md. Solayman Khan
Post lab questions:1. Submit the experimental datasheet.2. Theoretically calculate the voltage V1, V2, V3, V4 and the
currents I1, I2, I3, I4, I5 and I6 using nodal analysis.Use the measured values of the resistors in this calculation.
3. Compare the calculated values with the measured values and comment on any observed discrepancy.
4. Due to uncertainties and errors associated with measurements,experimental data dusually do not exactly satisfy theoretical equations.In case of this experiment,how much discrepancy can be considered acceptable?Give justification for your answer.
Answer to the que no. 1 :
Data Sheet:
R1() R2() R3() R4()32.7 32.5 48.1 98.9
V1(v) V2(v) V3(v) V4(v)1.65 -0.65 3.4 1.03
I1(mA) I2(mA) I3(mA) I4(mA) I5(mA) I6(mA)49.3 19.3 68.9 9.9 59.3 9.4
Objective:The main object of this experiment is to verify
kirchhoff's voltage and current laws .
Figure 1 :
Answer to the que no 2:
At node 1: -I5+I4+I1=0 ................ (i)
At node 2: I2-I4-I6=0 ................ (ii)
At node 3: I1+I2-I3= ................(iii)
At Loop 1-3-0-1:
V1+V3-VS1=0
I1×32.7+I3×48.1-5=0 I1=5−48.1×I 3
32.7 ............. (iv)
At Loop 3-2-0-3:
V2+VS2-V3=0
-I2×32.5+4-I3×48.1=0 I2=4−48.1 I 3
32.5 ............ (v)
From (iii),(iv),(v) =>
5−48.1×I 332.7 +4−48.1×I 3
32.5 =I3
162.5-1563.25×I3+130.8-1572.87×I3=1062.75×I3 I3= 293.43
4198.87=0.06985A=69.85mA ........(vi)
So,V3=I3R3=0.06985×48.1=3.36V ........(vii)
Place ,I3=0.06985mA at (iv) =>
I1= 5−48.1×0.0698532.7 =0.05016A=50.16mA ........(viii)
So,V1=I1R1=0.05016×32.7=1.64V ........( xi)
Place ,I3=0.06985mA at (iv) =>
I2= 4−48.1×0.0698532.5 =0.0197A=19.7mA ........(x)
So,V2= -I2R1= -0.0197×32.5= -0.64V ........(xi)
Now, At Loop 1-2-0-1:
V4+VS2+-VS1=0
V4+4-5=0 V4=1 ........(xii)
So,
I4=V 4R4 = 1
98.9=0.01011A=10.11mA ........(xiii)
From (i) => -I5+I4+I1=0
=>I5=I4+I1
=> I5=0.01011+0.05016=0.6027A=60.27mA ........(xiv)
From (ii) => I2-I4-I6=0
=>I6=I2-I4
=> I6=0.0197-0.01011=0.00959A=9.59mA ........(xv)
From (vi) to (xv),the values of I1, I2, I3, I4, I5, I6, V1,V2,V3,V4 are Calculated.
Here,
I1=50.16mA ; V1=1.64v
I2= 19.70mA ; V2= -0.64v
I3= 69.85mA ; V3=3.36v
I4= 10.11mA ; V4=1.00v
I5= 60.27mA
I6= 9.59mA
Answer to the que no 3: Comparison Between Calculated and Measured Values of Voltages :
V1(v) V2(v) V3(v) V4(v)Calculated
Values1.64 -0.64 3.36 1.00
Measured Values
1.65 -0.65 3.40 1.03
Comparison Between Calculated and Measured Values of Currents :
I1(mA) I2(mA) I3(mA) I4(mA) I5(mA) I6(mA)Calculated Values
50.16 19.70 69.85 10.11 60.27 9.59
Measured Values
49.30 19.30 68.90 9.90 59.30 9.40
Comment: All the measured values of voltage of resistors was a little bit greater than the calculated values.On the other hand, All the measured values of flow of current was a little bit smaller than the calculated values.Without this,i didn’t see any discrepancy between my measurement and calculation.
I think, the voltage of VS2 Was a little bit higher than 4V, So, all voltages became little bit high.
As voltage rised,So logically it is sure that the current should also be high but here all the measured values of currents are lower than the calculated values of currents.
Answer to the que no:4
The percentage of discrepancy that i saw between my equation and calculation is given below:
percentage of discrepancy of voltage at V1: 1.65−1.641.65
×100 % =0.60%
percentage of discrepancy of voltage at V2: −.65−(−.64)−.65
×100 % =1.53%
percentage of discrepancy of voltage at V3: 3.40−3.363.40
×100 % =1.17%
percentage of discrepancy of voltage at V4: 1.03−1.001.03
×100 % =2.91%
percentage of discrepancy of Current at I1: 50.16−49.3050.16
×100 % =1.71%
percentage of discrepancy of Current at I2: 19.70−19.3019.70
×100 % =2.03%
percentage of discrepancy of Current at I3: 69.85−68.9069.85
×100 % =1.36%
percentage of discrepancy of Current at I4: 10.11−9.9010.11
×100% =2.07%
percentage of discrepancy of Current at I5: 60.27−59.3060.27
×100 % =1.60%
percentage of discrepancy of Current at I6: 9.59−9.409.59
×100% =1.98%
In this experiment, i got higher discrepancy at R4.
And it is =: 1.03−1.001.03
×100 % =2.91%
So,i think for this experiment,less than 3.0% discrepancy can be considered acceptable.That is why,because,in this experiment, i didn’t face any discrepancy more than 3% .
PRE- LAB