· web viewthe system complies with the minimum environmental criteria dm 11 october 2017, the...

7
FALSE CEILING “ATENA ENIGMA” Supply of a metal false ceiling for interiors, made with modular side-by-side clip-in panels of the “Atena Enigma” type, installed on hidden structure, complete with PVC fixing clips, having: Sizes (mm): 600x600 | 600x1200 | 625x625 300x300 | 300x1200 | 300x1500 400x1000 | 400x1200 | 400x1500 Edge: right angle | beveled edge The system will consist of panels obtained from the processing of coils of: ALUMINUM (3105 alloy), corrosion resistance class C5. thickness: 5/10 (*) | 6/10 mm (*) : thickness available only on specific tile sizes: 600x600 | 625x625 | 300x300 mm finishing: Atena White | Atena Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side. RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearance Electrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion. STEEL thickness: 5/10 mm finishing: Atena White | Atena Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side.

Upload: others

Post on 09-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1:  · Web viewThe system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances

FALSE CEILING“ATENA ENIGMA”

Supply of a metal false ceiling for interiors, made with modular side-by-side clip-in panels of the “Atena Enigma” type, installed on hidden structure, complete with PVC fixing clips, having:

Sizes (mm): 600x600 | 600x1200 | 625x625 300x300 | 300x1200 | 300x1500 400x1000 | 400x1200 | 400x1500

Edge: right angle | beveled edge

The system will consist of panels obtained from the processing of coils of: ALUMINUM (3105 alloy), corrosion resistance class C5.

thickness: 5/10(*) | 6/10 mm(*): thickness available only on specific tile sizes: 600x600 | 625x625 | 300x300 mm

finishing: Atena White | Atena Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side.

RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearanceElectrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion.

STEEL thickness: 5/10 mm

finishing: Atena White | Atena Silver with primer on hidden side and matt (about 25 gloss) pre-painted visible side.Corrosion resistance class C3.

RAL_____________ | NCS____________ Smooth surface: Glossy | Semi-glossy | Matt Matt wrinkled appearanceElectrostatic post-painting with a special mixture of polyester resins, which ensure color stability over time; declared thickness not less than 80µm, nanotechnological pre-treatment for greater resistance to corrosion.Corrosion resistance class C4.

Panels will have the following characteristics: plain surface | perforated surface

Page 2:  · Web viewThe system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances

Available perforations:

Parallel AP 0,75/2% AP 1/5% P AP 1,5/11% P AP 1,8/9,5% P AP 2/12,5% P AP 2,5/15% P AP 3/7,5% P AP Q4/20% P AP Q10/25% P AP Q10/34 % P

Diagonal AD 1/10% D(*) AD 1,5/22% D AD 1,8/19% D AD 2/25% D AD 2,5/30% D AD 3/15% D AD 3/51% D (**) AD 5/53% D (**) QUASAR (*) = only for 0,5mm thickness | (**) = not for 0,5mm thickness

Tissue Tweed Tweed Large Tweed Fine Tweed Unique Strip Piquet

Mesh R16x8/A2,5 R25x12,5/A2

Perforated area: Standard with plain frame | 400x400mm Other - specify____________

with thermoadhesive black acoustic tissue applied; fire reaction class: A1 A2s1d0

The false ceiling will have the following values: ɑw* __________e NCR* _________ * The acoustic characteristics of Atena products have been tested in accordance with ISO 10534, by an independent certified laboratory, the results on the acoustic absorption of the individual models have therefore been calculated using the ALPHACELLR software that uses the TIMM method for forecasting acoustic performance of pore-elastic multilayer materials. This is a system that takes into account the air resistivity, the porosity, the tortuosity and viscosity, the thermal characteristics and the permeability of the materials, which constitute the panel under test. The sound-absorbance and sound-impedance values of the panels depend on a series of factors such as the percentage of perforated area, the type of absorber / acoustic insulation coupled to the panel and the plenum value. Please therefore request Atena the values of ɑw and NCR or db to be reported in the specifications.Following models have been tested and certified in accordance with EN ISO 354:

“Atena Metal Sound” AP1,8/19%D ɑw0,70 “Atena Metal Soft” AP1,8/19%D ɑw0,85“Atena Metal Sound” AP1,8/9,5%P ɑw0,75 “Atena Metal Soft” AP1,8/9,5%P ɑw0,85“Atena Metal Sound” AP1,5/22%D ɑw0,60“Atena Metal Sound” AP2/12,5%P ɑw0,65“Atena Metal Sound” AP2,5/30%D ɑw0,60

STANDARD STRUCTURE*Panels will be placed clipped-in Atena hidden structure with corrosion resistance class C3.

SINGLE TRIANGULAR STRUCTUREComposed by triangular galvanized steel profiles, 5/10 mm thick, placed at a distance of: 300 | 600 | 625 mmTS fixing clip made in 10/10mm galvanized steel and Ø4mm double hanger with spring.

DOUBLE TRIANGULAR STRUCTURE + WINGER HOOKComposed by triangular galvanized steel profiles, 5/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mmAnd 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the triangular profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Suspension made with a spring hook and Ø4mm galvanized steel hanger.

Page 3:  · Web viewThe system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances

SINGLE CONTINENTAL STRUCTURE

Composed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 600 | 625 mmHanging bracket Atena CS made in galvanized steel, 8/10 mm, and two Ø4mm hangers with double spring.

DOUBLE CONTINENTAL STRUCTURE + WINGER HOOKComposed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm And 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the continental profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Suspension made with a spring hook and Ø4mm galvanized steel hanger.

DOUBLE CONTINENTAL STRUCTURE + “U” PROFILEComposed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm “U” shaped holed profile made in 15/10 mm thickness galvanized steel, placed at a distance of 1200mm and connected to the continental profiles with specific crossing bracket made in 10/10 mm thickness galvanized steel to be applied at any crossing between continental and “U” profiles. Lock it with the safety clips.Hanging with Ø6mm threaded bar for holed “U” profiles and related bracket.

Perimeter profiles of the same material and finish of the panels with section “C” 18x33x25mm, complete with h30 omega spring to lock the tiles.

* NOTES FOR APPLICATION OF PROFILES AND PANELS: With post-painted steel panels, use a galvanized continental profile With pre-painted steel panels, use a galvanized triangular profileWith aluminum panels, use a pre-painted steel triangular profile.

ANTISEISMIC STRUCTURE with ATENA KIT for PLENUM SPACE < 1,2 mPanels will be clipped-in on Atena hidden structure, in corrosion resistance class C3.

DOUBLE TRIANGULAR STRUCTURE + WINGER HOOKComposed by triangular galvanized steel profiles, 5/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mmAnd 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the triangular profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Suspension made with a spring hook and Ø4mm galvanized steel hanger.

DOUBLE CONTINENTAL STRUCTURE + WINGER HOOKComposed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm And 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the continental profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Suspension made with a spring hook and Ø4mm galvanized steel hanger.

Page 4:  · Web viewThe system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances

DOUBLE CONTINENTAL STRUCTURE + “U” PROFILE

Composed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm “U” shaped holed profile made in 15/10 mm thickness galvanized steel, placed at a distance of 1200mm and connected to the continental profiles with specific crossing bracket made in 10/10 mm thickness galvanized steel to be applied at any crossing between continental and “U” profiles. Lock it with the safety clips.Hanging with Ø6mm threaded bar for “U” holed profiles and related bracket.

Perimeter profiles of the same material and finish of the panels with section “C” 18x33x25mm, complete with h30 omega spring to lock the tiles. Atena Bracing kit for plenum spaces lower than 1,2m consisting of a specific cross connection, holed bracing profiles to be fixed to the slab (4000mm length, to be cut on site), and fixing brackets. As an alternative, instead of using the fixing brackets, the holed bars can be bended on site with “FLEXA”, Atena’s specific bending tool, to be fixed directly to the slab. Anti-seismic kits must be sized according to the building structural characteristics, its intended use and geographical location of the installation site. Anti-seismic Atena report is preparatory for commissioning.

* NOTES FOR APPLICATION OF PROFILES AND PANELS: With post-painted steel panels, use a galvanized continental profile With pre-painted steel panels, use a galvanized triangular profileWith aluminum panels, use a pre-painted steel triangular profile.

ANTISEISMIC STRUCTURE with ATENA KIT “BIG HEIGHTS” for PLENUM SPACE > 1,2 mPanels will be clipped-in on Atena hidden structure, in corrosion resistance class C3.

DOUBLE TRIANGULAR STRUCTURE + WINGER HOOKComposed by triangular galvanized steel profiles, 5/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mmAnd 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the triangular profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Rigid hanging with Bridge bracket h30 and Ø6mm threaded bar, or Nonius type hanger for 49x27mm carrier.

DOUBLE CONTINENTAL STRUCTURE + WINGER HOOKComposed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm And 49x27mm galvanized steel carriers, 6/10 mm thick, placed at a distance of 1200mm and fixed to the continental profiles with the patented Winger hook made in 8/10mm galvanized steel to be applied at any crossing. Rigid hanging with Bridge bracket h30 and Ø6mm threaded bar, or Nonius type hanger for 49x27mm carrier.

DOUBLE CONTINENTAL STRUCTURE + “U” PROFILEComposed by “continental” galvanized steel profiles, 6/10 mm thick, placed at a distance of: 300 | 400 | 600 | 625 | 1000 | 1200 | 1500 mm “U” shaped holed profile made in 15/10 mm thickness galvanized steel, placed at a distance of

Page 5:  · Web viewThe system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances

1200mm and connected to the continental profiles with specific crossing bracket made in 10/10 mm thickness galvanized steel to be applied at any crossing between continental and “U” profiles. Lock it with the safety clips.Hanging with Ø6mm threaded bar for “U” holed profiles and related bracket.

Perimeter profiles of the same material and finish of the panels with section “C” 18x33x25mm, complete with h30 omega spring to lock the tiles. Atena Bracing kit “Big Heights” for plenum spaces larger than 1,2m consisting of tubular with pitch holes and bracing connecting brackets, universal joints for fixing to the slab, a specific cross-joint to connect the kit to the Easy Anti-seismic structure and related screws (M8x70 and M4,2x13).Anti-seismic kits must be sized according to the building structural characteristics, its intended use and geographical location of the installation site. Anti-seismic Atena report is preparatory for commissioning.

* NOTES FOR APPLICATION OF PROFILES AND PANELS: With post-painted steel panels, use a galvanized continental profile With pre-painted steel panels, use a galvanized triangular profileWith aluminum panels, use a pre-painted steel triangular profile.

The system complies with the Minimum Environmental Criteria DM 11 October 2017, the specific applicable standards UNI EN 13964 and 14195; does not release hazardous substances into the environment including formaldehyde. Painting and / or sublimation will be performed with substances free from Volatile Organic Compounds (VOCs). All products and components supplied will be accompanied by D.O.P. EC Declaration of Performance in accordance with the European regulation of construction products 305/2011. The artifacts will be recyclable and in their entirety derived from the use of materials from recycling processes, with content of recycled material, calculated for each type of product, compliant with CAM requirements and declared as required by the ISO 14021 standard. The false ceiling system contributes to obtaining credits for the design, construction and sustainable and efficient management of buildings according to the LEED protocol and according to the BREEAM and ITACA protocols for cross-cutting aspects.

NOTES: Atena Spa has adopted a quality management system in compliance with the UNI EN ISO 9001 standard.All Atena false ceilings are produced for indoor applications in compliance with the specific applicable technical standards and with the requirements of the “Norme Tecniche per le Costruzioni” NTC 2018 DM January 17, 2018 and relative circular; the performance properties declared in the relative D.O.P. are insured by Atena S.p.A. provided that the false ceilings are installed in the environmental conditions, for which they have been designed and have been subjected to the normal recommended maintenance activities. Specifically, false ceilings as non-structural construction elements must be appropriately sized in order to withstand with adequate security all those actions that can induce states of solicitation to the building; thermal, humidity, etc., in relation to the installation site, the intended use of the building and the technical characteristics of the project. It is therefore recommended to check with the Atena technical office the specific environmental conditions to which the product will be subjected in order to choose the most suitable materials for the installation site. In the case of outdoor installation, false ceilings are not within the scope of a harmonized technical standard and therefore are not subject to regulation 305/2011. They are in any case subjected to the NTC 2018 and to the safety checks of civil constructions and therefore they must be specifically sized according to the environmental conditions of the installation site, to the structural characteristics of the building and to the project specifications.