well pump systems - duramactm booster pumpsduramactm model pump boost amps length “l” voltage...
TRANSCRIPT
-
1-19 213800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
Jet PumpsJet Pum
ps
DuraMACTM Booster Pumps
Pump Catalog - January 2019
MORE THAN A BRAND. WE’RE A FAMILY.
DuraMAC
TM Booster Pumps
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19214
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
Typical InstallationsNot all boosting applications require complicated boosting systems. The DuraMACTM Booster System is simple, versatile, sophisticated, and reliable. Quite simply, it is the World’s Most Versatile Boosting System.
VersatileIt is the first booster pump of its kind to be designed for virtually all boosting applications. In Pressure Mode, the pump starts with pressure drop and stops on low flow. In Flow Mode, the pump starts and stops by sensing flow. In Conservation Mode, the pump only operates during a peak demand, such as when multiple showers, bathtubs, or irrigation systems are running.
SimpleA single-speed, totally enclosed fan-cooled motor drives the DuraMAC™ booster pump with single phase power. It is controlled with one dial and tells you it is working properly by illuminating a single status light. The settings and readouts are simple and straight forward.
SophisticatedA pressure transducer constantly monitors system pressure and alerts the pump control to start the pump as water in the system is used. The pump then stays on, boosting the system pressure until the need for water is no longer present, indicated by low flow.
ReliableElectronic components are completely separated from piping and water ways for added safety and ease of field repair. The DuraMAC™ is built from scratch with one purpose in mind - boosting water pressure. Each component of the system is specifically designed to work together, as one harmonious unit.
STAND PIPE
PRIME PLUG
FOOT VALVE
OUTLET
SUCTION PIPE
VALVE
PUMP FILL PLUG
OUTLET
INLET
UNION
PUMP FILL PLUG
VALVE
CHECK VALVEUNION
PRESSURE REDUCING VALVE(SEE INSTRUCTIONS)
VALVE
BYPASS VALVECLOSED
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 215
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
The World’s Most Versatile Booster SystemPressure TankEliminates short cycling and helps accommodate thermal expansion.
Pressure GaugeDisplays total system pressure
Circuit BoardSophisticated programming assures proper operation in all conditions.
Digital ControlSingle knob for simple pressure adjustment. Status light indicates standby, run and fault modes
TransducerConstantly monitors system pressure.
Inlet w/Check Valve: ResidentialNo-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections
Inlet w/Check Valve: Light CommercialNo-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections
Union SwivelAllows for 360o adjustment of discharge.
MotorTotally enclosed fan-cooled motor for quiet operation and low power consumption
PumpAll stainless construction for tough water conditions.
Dual-Mode Modular, Simplex, & Duplex
Vertical Multistage Variable Speed
Simplex & Duplex Boosters
E-Series, Residential, Light Commercial,
& Irrigation Boosters
A.Y. McDonald’s Full Line of DuraMACTM Booster Pumps
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19216
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
How to OrderOrder by Model Number - Example: 17044C070PC2-M
P C 2 - M17 044 C 070Series1718
Water Pressure at 0 GPM035040044052060062070078
TypeR - ResidentialC - Commercial
OptionsD - DuplexM - ModularS - Simplex
SS - Stainless Steel*Only available in E-Series
GPM020035070120
Voltage1 - 120V2 - 230V
Models Available - Residential, Light Commercial, & Irrigation Boosters 17035R020PC1 17040C035PC2 17052R020PC1 17062C035PC2 17070R020PC2 17078C035PC2
Models Available - E-Series
18035R020PC1 18052R020PC1
Models Available - Dual-Mode - Modular, Simplex, & Duplex Models 17044C070PC2-S 17060C070PC2-M 17060C070PC2-S 17044C120PC2-D 17044C070PC2-M 17060C120PC2-D
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 217
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
The DuraMACTM Water Pressure Boosting System can be set to three separate modes, which can accommodate virtually any application.
New Pump Control 115V115V DC: B17 - Current230V DC: F17 - Current
How It Works
DuraMACTM Residential, Light Commercial, & Irrigation Pump Control(excludes E-Series)
PRESSURE MODE START METHOD: Pressure drop STOP METHOD: Low flow TYPICAL INSTALLATION: Appropriate for the majority of light commercial or residential applications RESULT: Pump operates continuously while there is a need for water
FLOW MODE START METHOD: Water flow STOP METHOD: Low flow TYPICAL INSTALLATION: Application where pressure fluctuates, or occasional system leaks are present RESULT: Pump operates when usage of water exceeds approximately one gallon per minute
CONSERVATION MODE START METHOD: Pressure drop
STOP METHOD: Low Flow
TYPICAL INSTALLATION: Application where pressure is adequate for most uses, and boosting is only necessary for high demand
RESULT: Pump will operate only when system pressure is below city supplied pressure and operate continuously while there is demand for water
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19218
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM Booster PumpNot all boosting applications require complicated boosting systems. The DuraMAC™
Boosting system is simple, versatile, sophisticated, and reliable. With an easy set-up installation and a versatile control with three modes of operation, this pump is exible enough to meet your commercial or irrigation needs.
The 304 stainless steel version of the DuraMAC™ Booster pump will meet the needs of boosting water pressure from Reverse Osmosis (RO) systems, low PH and other agressive water applications which would be corrosive to no-lead brass and metal pipes.
Features:- Water pressure boosting system for residential, irrigation, or light commercial use
- Easy set-up installation
- All metal connections - no plastic threads
- Half-gallon pressure tank included
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- No-Lead Brass / 304 stainless steel check valve included
- Dry-Run protection
- 1” inlet and outlet
- 1 year warranty
Models AvailableDuraMACTM Model
Pump Boost Amps Voltage Power Weight
18035R020PC1 35 PSI 5.5 120 - 60 Hz 1/2 HP 27.118052R020PC1 52 PSI 7.0 120 - 60 Hz 3/4 HP 27.718035R020PC1SS 35 PSI 5.5 120 - 60 Hz 1/2 HP 27.118052R020PC1SS 52 PSI 7.0 120 - 60 Hz 3/4 HP 27.7
See Pumps & AccessoriesPrice List for Limited Warranty details.
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass / Stainless Steel - Pump Controller Cross No-Lead Brass / Stainless Steel
80
70
60
50
40
30
20
10
00 5 10 15
Flow GPM
DuraMACTM Performance (Additional Boost)
Pres
sure
PSI
20
18052R020PC1
18035R020PC1PSI+35
+52PSI
s. The DuraMAC™
With an easy set-n, this pump is
Pric
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 219
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
E-Series DuraMACTM Booster Pump
Typical Installation
Sizing InformationE-Series DuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump total pressure boost should be added to current household system pressure to determine total system pressure when boosted. Note: It is not recommended to exceed 80 PSI total boosted household pressure.
Example:Household system pressure before boost = 30 PSI
30 + = Household Total Pump Total Pressure Pressure Pressure After Boost
Models Available: Boost18035R020PC1 +3518052R020PC1 +52
30 + 35 = 65 Household Total Pump Total Pressure Pressure Pressure After Boost
*Not Recommended to Exceed 80 PSI
Based on this example, the recommended model for this application is the 18035R020PC1. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.
Total static pressure DuraMAC™ pumpSizing Chart
Dimensional Information
+35PSI
+52PSI
CONTACT FACTORY
Incoming 18035R020PC1 18052R020PC1 Pressure (PSI) 60 55 90 50 85 45 80 40 75 35 70 87 30 65 82 25 60 77 20 55 72 15 50 67 10 45 62
OUTLET
INLETVALVE
PRESSURE REDUCING VALVE(WELL SYSTEMS SET 20-30 PSI)
(CITY SUPPLY - READ INSTRUCTIONS)RECOMMENDED FOR SOME
BYPASS VALVE CLOSED
UNION
GAUGE - RECOMMENDED
CHECK VALVE
VALVE
UNION
120VAC
60HZ 10
FLA 60
LRA
PUMP ST
ARTS ON
PRESSU
RE OR FL
OW
GREEN - S
TANDBY
RED - LOW
PRESSUR
EBLUE
- RUN
PUMP ST
OPS ON
LOW FLO
W
WWW.AY
MCDONA
LD.COM
INDOOR
USE ONL
YNEMA 1
15300PC
DuraMAC
TM E-Series
PUMP CO
NTROL
CITY OR WELL SUPPLY
SUCTION LIFT
120VAC 60HZ
10 FLA 60 L
RA
PUMP STARTS
ON PRESSUR
E OR FLOW
GREEN - STANDB
Y
RED - LOW PRES
SUREBLUE - RU
N
PUMP STOPS
ON LOW FLOW
WWW.AYMCD
ONALD.COM
INDOOR USE
ONLYNEMA 115300
PC DuraMAC
TM E-Series PUMP
CONTROL
SUCTION PIPE
OUTLET
FOOT VALVE
PRIME PLUG
STAND PIPECHECKVALVE
GAUGE - RECOMMENDED
10 Ft. Max
4.25"
3.5"
5.5" 3.5"4.0"
16.5"
4.0"
5.25"
120VAC 60HZ 10 FLA 60 LRA
GREEN - STANDBY
RED - LOW PRESSUREBLUE - RUN
15300PC DuraMACTM E-Series PUMP CONTROL
PUMP STOPS ON LOW FLOWWWW.AYMCDONALD.COM INDOOR USE ONLY
NEMA 1
PUMP STARTS ON PRESSURE OR FLOW
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19220
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Residential BoosterNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world’s most versatile boosting system for residential use.
Features:- Easy set-up installation
- Digital control for three modes of operation
- Durable stainless steel and no-lead brass connections
- Two gallon pressure tank included
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- Pressure gauge included
- No-Lead brass check valve included
- Dry-Run protection
20 Gallon / Minute (GPM) MaxDuraMACTM Model
Pump Boost Amps
Length “L” Voltage Power
*Pressure Reducing Valve Recommended for installation with incoming pressure greater than: Wt.
17035R020PC1 35 PSI 5.5 15.26” 120 - 60 Hz 1/2 HP 45 PSI 33
17052R020PC1 52 PSI 7.0 15.97” 120 - 60 Hz 3/4 HP 28 PSI 37
17070R020PC2 70 PSI 4.0 16.68” 230 - 60 Hz 1 HP 10 PSI (for use with holding tank) 40
See Pumps & AccessoriesPrice List for Limited Warranty details.
17070R020PC2
80
70
60
50
40
30
20
10
00 5 10 15 20
17052R020PC1
17035R020PC1PSI+35
PSI+70
+52PSI
Pres
sure
PSI
Flow GPM
DuraMACTM Performance Curve (Additional Boost)
*Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure.
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 221
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Residential Booster
Incoming 17035R020PC1 17052R020PC1 17070R020PC2 Pressure (PSI)
60 55 90 50 85 45 80 40 75 35 70 87 30 65 82 25 60 77 20 55 72 90 15 50 67 85 10 45 62 80
Typical Installation
Sizing InformationDuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted.
Example:Household system pressure before boost = 30 PSI
30 + = Household Total Pump Total Pressure Pressure Pressure After Boost
Models Available: Boost17035R020PC1 +3517052R020PC1 +5217070R020PC2 +70
30 + 35 = 65 Household Total Pump Total Pressure Pressure Pressure After Boost
*Not Recommended to Exceed 80 PSI
Based on this example, the recommended model for this application is the 17035R020PC1. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.
25”
3.5”
11.2”
8”
ADD AND MEASURE AIR PRESSURE HERENOTE: WATER PRESSURE MUST BE 0 PSI WHEN ADJUSTING AIR PRESSURE
*L
4” 5.5”
4.25”
1"Male NPT
Check Valve
1"Female NPT
3.5”
11.2”
8”
4.25”
+35 +52 +70
Total static pressure DuraMAC™ pump
CONTACT FACTORY
Sizing Chart
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass - Pump Controller Cross No-Lead Brass
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19222
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Light Commercial & IrrigationNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With an easy set-up installation and a versatile control with three modes of operation, this pump is exible enough to meet your commercial or irrigation needs.
Features:- Easy set-up installation
- Digital control for three modes of operation
- Durable stainless steel and no-lead brass connections
- Two gallon pressure tank included
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- Pressure gauge included
- No-Lead brass check valve included
- Dry-Run protection
35 Gallon / Minute (GPM) MaxDuraMACTM Model
Pump Boost Amps
Length “L” Voltage Power
*Pressure Reducing Valve Recommended for installation with incoming pressure greater than: Wt.
17040C035PC2 40 PSI 5.0 15.43” 230 - 60 Hz 1 HP 40 PSI 38
17062C035PC2 62 PSI 6.3 16.49” 230 - 60 Hz 1 HP 18 PSI 41
17078C035PC2 78 PSI 6.8 17.55” 230 - 60 Hz 1 1/2 HP 2 PSI (for use with holding tank) 35
See Pumps & AccessoriesPrice List for Limited Warranty details.
17078C035PC2
0 5 10 15
80
70
60
50
40
30
20
10
020 25 30 35
17062C035PC2
17040C035PC2PSI+40
PSI+78+62PSI
DuraMACTM Performance Curve (Additional Boost)
Pres
sure
PSI
Flow GPM
*Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure.
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 223
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Light Commercial & Irrigation
Typical Installation
Sizing InformationDuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted.
Example:Household system pressure before boost = 30 PSI
30 + = Household Total Pump Total Pressure Pressure Pressure After Boost
Models Available: Boost17040C035PC2 +4017062C035PC2 +6217078C035PC2 +78
30 + 40 = 70 Household Total Pump Total Pressure Pressure Pressure After Boost
*Not Recommended to Exceed 80 PSI
Based on this example, the recommended model for this application is the 17040C035PC2. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.
Total static pressure DuraMAC™ pumpSizing Chart
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass - Pump Controller Cross No-Lead Brass
+40PSI
+62PSI
+78PSI
CONTACT FACTORY
Incoming 17040C035PC2 17062C035PC2 17078C035PC2 Pressure (PSI) 60 55 50 90 45 85 40 80 35 75 30 70 25 65 87 20 60 82 15 55 77 93 10 50 72 88
25"
ADD AND MEASURE AIR PRESSURE HERE NOTE: WATER PRESSURE MUST BE 0 PSI WHEN ADJUSTING AIR PRESSURE.
*L
4" 5.5"
1 1/4" FEMALE NPT
1" FEMALE NPT10
2030
40 50 6070
80
90100PSI
CHECK VALVE
3.5"
10.8"
8"
4.3"
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19224
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Dual Mode ModularNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With a quick and easy installation, and unique digital control featuring dual modes of operation, this pump can meet your unique commercial or irrigation needs.
Features:- Easy set-up installation
- Digital control with dual modes of operation
- Durable stainless steel and no-lead brass connections
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- Pressure gauge included
- No-Lead brass check valve included (meets no-lead compliance)
70 Gallon / Minute (GPM) Max
DuraMACTM Model Description
Pump Boost Amps Voltage Power
*Pressure Reducing Valve Recommended for installation with
incoming pressure greater than: Wt.
17044C070PC2-M 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 56
17060C070PC2-M 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 56
*Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.
0 10 20 30
80
70
60
50
40
30
20
10
040 50 60 70
PSI+60
PSI+44
DuraMACTM Performance Curve (Additional Boost)
Pres
sure
PSI
Flow GPM
17060C070PC2-M
17044C070PC2-M
See Pumps & AccessoriesPrice List for Limited Warranty details.
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 225
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Dual Mode ModularControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC
15100PC2 DUAL~MODE
FLOW STOP
CC USUS
STAND BY
PRESSURE START PRESSURE STOP
WWW.AYBOOSTERS.COM
RUN FAULT
10 PSI MIN
TESTRESET /
PRESSURE START
2 PSI LESS THAN START PRESSUREAIR PRESSURE IN TANK SHOULD BE
PUMP CONTROL
230VAC 60HZ 8.8 FLA 48 LRA
TM DuraMAC
FOR INDOOR USE ONLY
4.65"
4.25"7.3"
21.5"
5.43" 4.96"15.1"
1 1/2"NPT
1 1/2"NPT
CheckValve
PSI 10090
8070
60504030
20
10
Dual-Mode Modular Shown. Skid mounted Simplex and Duplex available.
In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.
This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.
PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow
In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.
FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow
10
20
3040
50
60
700
SET 10-15 PSI BELOWBOOSTED PRESSURE
PUSH RESET
START PRESSURE
STAND BY FAULTRUNRESET
FLOW
PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY
15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA
WWW.AYBOOSTERS.COM
TM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19226
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Dual Mode Simplex
70 Gallon / Minute (GPM) Max
DuraMACTM Model Description
Pump Boost Amps Voltage Power
*Pressure Reducing Valve Recommended for installation with
incoming pressure greater than: Wt.
17044C070PC2-S 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 168
17060C070PC2-S 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 168
*Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.
Not all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With the ability to pump up to 70 GPM this unique pump is ideal for commercial or irrigation use.
Features:- Easy set-up installation
- Digital control with dual modes of operation
- Durable stainless steel and no-lead brass connections
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- Pressure gauge included
- No-Lead brass check valve included
- Up to 70 GPM
- 20 gallon pressure tank included
- Stainless steel base
- Dry run protection
ms.nd eal
0 10 20 30
80
70
60
50
40
30
20
10
040 50 60 70
PSI+60
PSI+44
DuraMACTM Performance Curve (Additional Boost)
Pres
sure
PSI
Flow GPM
17060C070PC2-S
17044C070PC2-S
See Pumps & AccessoriesPrice List for Limited Warranty details.
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 227
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Dual Mode SimplexControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC - Base 304 Stainless Steel
Simplex base mounted with 20 gallon tank.
28"18"
6.2"
24.5"34"
1 1/2" NPT
1 1/2" NPT
Check Valve
In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.
This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.
PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow
In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.
FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow
10
20
3040
50
60
700
SET 10-15 PSI BELOWBOOSTED PRESSURE
PUSH RESET
START PRESSURE
STAND BY FAULTRUNRESET
FLOW
PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY
15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA
WWW.AYBOOSTERS.COM
TM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19228
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Dual Mode Duplex
120 Gallon / Minute (GPM) Max
DuraMACTM Model Description
Pump Boost Amps Voltage Power
*Pressure Reducing Valve Recommended for installation with
incoming pressure greater than: Wt.
17044C120PC2-D 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 252
17060C120PC2-D 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 252
*Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.
Not all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world’s most versatile boosting system for commercial or irrigation use.
Features:- Easy set-up installation
- Digital control with dual modes of operation
- Durable stainless steel and no-lead brass connections
- TEFC single phase motor for quiet operation
- Electronics separated and sealed from waterway
- Pressure gauge included
- No-Lead brass check valve included
- Designed for Lead-Lag
- Up to 120 GPM
- 20 gallon pressure tank included
- Stainless steel base
- Dry run protectionSee Pumps & Accessories
Price List for Limited Warranty details.
ting tile,
most
See Pumps & AccessoriesPrice List for Limited Warranty details.
0 20 40 60 80 100 120
70
60
50
40
30
20
10
0
PSI+60
PSI+44
Pres
sure
PSI
Flow GPM
DuraMACTM Performance Curve (Additional Boost - Both Pumps Running)17060C120PC2-D
17044C120PC2-D
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 229
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Dual Mode SimplexControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC - Base 304 Stainless Steel
10
20
3040
50
60
700
SET 10-15 PSI BELOWBOOSTED PRESSURE
PUSH RESET
START PRESSURE
STAND BY FAULTRUNRESET
FLOW
PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY
15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA
WWW.AYBOOSTERS.COM
TM
Duplex base mounted with 20-gallon tank 2” NPT manifolds with ball valves.36"
34"
27"
6.2"
28.5"
2" NPT
Check Valve
2" NPT
In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.
This smart system will only run the pump when water is in use. There is a preset seven7 second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.
PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow
In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.
FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19230
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
How to Order a Vertical Multistage Simplex / Duplex / Triplex SystemOrder by Model Number - Example: 17060V140Y-34
Y - 3 417 060 V 140Series Water Pressure
at 0 GPM056060062084088104140142150
Variable Speed
GPM080120140160240280360420
Yaskawa Drive
Phase1 - Single Phase3 - Three Phase
Volts4 - 460VLeave blank for 208 / 230 volts (standard)
Models Available - Simplex Models 17062V080Y-1 17150V080Y-3 17062V080Y-3 17142V120Y-3 17084V080Y-1 17056V120Y-1 17084V080Y-3 17060V140Y-3 17104V080Y-1 17088V140Y-3 17104V080Y-3
Models Available - Duplex Models 17062V160Y-1 17150V160Y-3 17062V160Y-3 17142V240Y-3 17084V160Y-1 17056V240Y-1 17084V160Y-3 17060V280Y-3 17104V160Y-1 17088V280Y-3 17104V160Y-3
Models Available - Triplex Models 17062V240Y-3 17150V240Y-34 17062V240Y-34 17142V360Y-3 17084V240Y-3 17142V360Y-34 17084V240Y-34 17060V420Y-3 17104V240Y-3 17060V420Y-34 17104V240Y-34 17088V420Y-3 17150V240Y-3 17088V420Y-34
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 231
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
How It WorksThe Yaskawa iQpump 1000 drive features powerful software combined with an internal PLC to deliver multiple features that are designed help protect the drive, pump, motor, and entire pumping system. While many of these features are factory programmed and set, many features depend on the speci c pumping application and may be required to be set during install.
Changing certain parameters while the drive and pump are running may cause unwanted behavior. It is recommended to turn the drive off before changing parameter values.
To return to home screen, hold for 3 seconds, or press . The display should look similar to the one below. Once at the home screen, additional drive status can be viewed by pressing . Additional drive information includes output frequency, current, voltage, DC bus voltage, and kilowatts.
Digital Operator Keypad Alarm light blinks if alarm or fault occurs.
Pump Output Frequency
Press to turn AUTO mode on.
If LED is blinking, Auto mode is active but pump is sleeping.
Transducer Feedback (Actual System Pressure)
System Outlet Pressure Auto Setpoint
Press to turn HAND mode on. Use only for Priming and troubleshooting. Pump will run at a xed speed.
Do not run against a closed discharge.
Press to turn system off.
DuraMACTM Vertical Multistage Variable Speed Simplex / Duplex / Triplex Booster Pump Control Features
- Set it and forget it technology- Set point at 50 PSI, but can be easily be changed in
the eld- Extremely reliable- Proven product- Yaskawa Drive
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19232
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Simplex Booster System
Models AvailableModel Description Pump Boost Voltage HP
17062V080Y-1 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Single Phase 3
17062V080Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3
17084V080Y-1 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Single Phase 5
17084V080Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5
17104V080Y-1 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Single Phase 5
17104V080Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5
17150V080Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2
17142V120Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10
17056V120Y-1 56 PSI 230V VFD Booster 56 PSI 208 - 230 - Single Phase 5
17060V140Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5
17088V140Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2
The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.
Features:- Easy set-up installation
- Variable speed control
- Stainless steel pump
- Energy ef cient NEMA TEFC motors
- Liquid lled gauges
- Wafer check valves with soft seat
- Stainless steel base
- 2” Brass No-Lead isolation valves
- NEMA 1 enclosure
- Suction and discharge transducers
- Fused disconnect
- 2” Suction and discharge
- Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016
See Pumps & AccessoriesPrice List for Limited Warranty details.
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
460 volt version also available
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 233
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Simplex Booster SystemControl Features
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide
- Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel
IN OUT
CHECK VALVE
30
4.6
30
50
- Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.
- Date and time stamp for all faults.
- Better system ef ciency by applying only the power needed based on the load.
- Password protected parameter settings.
- Real time clock.
- No Flow Mode - puts pump to sleep during no ow conditions.
- Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.
- Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.
- Live Zero protects the pump if the transducer cable is broken or damaged.
60 Hz Pump PerformanceOne Pump Running
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Flow GPM
Pres
sure
PSI
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
17150V080
17104V080
17084V080
17062V080
17142V120
17088V140
17060V140
17056V120
DuraMACTM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19234
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Duplex Booster System
Models AvailableModel Description Pump Boost Voltage HP
17062V160Y-1 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Single Phase 3
17062V160Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3
17084V160Y-1 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Single Phase 5
17084V160Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5
17104V160Y-1 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Single Phase 5
17104V160Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5
17150V160Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2
17142V240Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10
17056V240Y-1 56 PSI 230V VFD Booster 56 PSI 208 - 230 - Single Phase 5
17060V280Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5
17088V280Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2
The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.
Features:- Easy set-up installation
- Variable speed control
- Stainless steel pump
- Energy ef cient NEMA TEFC motors
- Liquid lled gauges
- Wafer check valves with soft seat
- Stainless steel base
- 2” Brass No-Lead isolation valves
- NEMA 1 enclosure
- Suction and discharge transducers
- Fused disconnect
- 3” Flanged stainless steel manifolds
- Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016
See Pumps & AccessoriesPrice List for Limited Warranty details.
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
460 volt version also available
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 235
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Duplex Booster SystemControl Features
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide
- Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel
- Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.- Lead - Lag pump control to alternate pump starts, allowing equal run times on all pumps for longer life cycles.- Better system ef ciency by applying only the power needed based on the load.- Password protected parameter settings.- Real time clock.- No Flow Mode - puts pump to sleep during no ow conditions.- Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.- Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.- Live Zero protects the pump if the transducer cable is broken or damaged.- Backup system transducer for pump and drive redundancy.
48
31
4.6
46
60 Hz Pump PerformanceBoth Pumps Running
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
Flow GPM
Pres
sure
PSI
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
17150V160
17142V240
17088V280
17060V280
17056V240
17104V160
17084V160
17062V160
DuraMACTM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19236
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Triplex Booster System
Models AvailableModel Description Pump Boost Voltage HP
17062V240Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3
17084V240Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5
17104V240Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5
17150V240Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2
17142V360Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10
17060V420Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5
17088V420Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2
The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.
Features:- Easy set-up installation
- Variable speed control
- Stainless steel pump
- Energy ef cient NEMA TEFC motors
- Liquid lled gauges
- Wafer check valves with soft seat
- Stainless steel base
- 2” Brass No-Lead isolation valves
- NEMA 1 enclosure
- Suction and discharge transducers
- Fused disconnect
- 4” Flanged stainless steel manifolds
- Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016
See Pumps & AccessoriesPrice List for Limited Warranty details.
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
460 volt version also available
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 237
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - Vertical Multistage Variable Speed Triplex Booster System
60 Hz Pump PerformanceAll Pumps Running
0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480
Flow GPM
Pres
sure
PSI
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
17150V240
17142V360
17088V420
17060V420
17104V240
17084V240
17062V240
DuraMACTM47
5.6
49
44
Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide
- Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel
- Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.
- Lead - Lag pump control to alternate pump starts, allowing equal run times on all pumps for longer life cycles.
- Better system ef ciency by applying only the power needed based on the load.
- Password protected parameter settings.
- Real time clock.
- No Flow Mode - puts pump to sleep during no ow conditions.
- Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.
- Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.
- Live Zero protects the pump if the transducer cable is broken or damaged.
- Backup system transducer for pump and drive redundancy.
Control Features
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19238
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - 17056V120Y Simplex / 17056V240Y Duplex Technical Information & Performance Curves
Max Boost 56 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 184TC
Horsepower 5
Seal Material Carbon/Sic
Electrical 208-230V 1 Phase
Base 304 Stainless Steel
Model Number 17056V120Y-1
Max Flow 120 GPM
Tank Required 32 Gallon
Model Number 17056V240Y-1
Max Flow 240 GPM
Tank Required 52 Gallon Minimum
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80 90 100 110 120 130
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Flow GPM
Pres
sure
PSI
80
70
60
50
40
30
20
10
0
17056V120Y Simplex / 17056V240Y Duplex
Duplex
Simplex
DuraMACTM
Technical Information Technical Information - Simplex Technical Information - Duplex
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 239
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - 17060V140Y Simplex / 17060V280Y Duplex17060V420Y Triplex Technical Information & Performance Curves
Max Boost 60 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 184TC
Horsepower 5
Seal Material Carbon/Sic
Base 304 Stainless Steel
Model Number 17060V140Y-3
Max Flow 140 GPM
Electrical 208-230V 3 Phase
Tank Required 36 Gallon
Model Number 17060V280Y-3
Max Flow 280 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon Minimum
Model Number 17060V420Y-3
Max Flow 420 GPM
Electrical 208-230V 3 Phase
Tank Required 86 Gallon Minimum
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
Flow GPM
Pres
sure
PSI
70
60
50
40
30
20
10
0
17060V140Y Simplex / 17060V280Y Duplex / 17060V420Y Triplex
DuplexSimplex
0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480Triplex
DuraMACTM
Technical Information Technical Information - Simplex
Technical Information - Duplex
Technical Information - Triplex
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19240
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM -17062V080Y Simplex / 17062V160Y Duplex17062V240Y TriplexTechnical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80
0 20 40 60 80 100 120 140 160
Flow GPM
Pres
sure
PSI
80
70
60
50
40
30
20
10
0
17062V080Y Simplex / 17062V160Y Duplex / 17062V240Y Triplex
Duplex
Simplex
0 30 60 90 120 150 180 210 240Triplex
DuraMACTM
Max Boost 62 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 182TC
Horsepower 3
Seal Material Carbon/Sic
Base 304 Stainless Steel
Model Number 17062V080Y-1
Max Flow 80 GPM
Electrical 208-230V 1 Phase
Tank Required 20 Gallon
Model Number 17062V080Y-3
Max Flow 80 GPM
Electrical 208-230V 3 Phase
Tank Required 20 Gallon
Model Number 17062V240Y-3
Max Flow 240 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon
Model Number 17062V160Y-1
Max Flow 160 GPM
Electrical 208-230V 1 Phase
Tank Required 52 Gallon Minimum
Model Number 17062V160Y-3
Max Flow 160 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Triplex
Technical Information - Duplex
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 241
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - 17084V080Y Simplex / 17084V160Y Duplex17084V240Y Triplex Technical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80
0 20 40 60 80 100 120 140 160
Flow GPM
Pres
sure
PSI
100
90
80
70
60
50
40
30
20
10
0
17084V080Y Simplex / 17084V160Y Duplex / 17084V240Y Triplex
Duplex
Simplex
0 30 60 90 120 150 180 210 240Triplex
DuraMACTM
Max Boost 84 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 184TC
Horsepower 5
Seal Material Carbon/Sic
Base 304 Stainless Steel
Model Number 17084V080Y-1
Max Flow 80 GPM
Electrical 208-230V 1 Phase
Tank Required 20 Gallon
Model Number 17084V080Y-3
Max Flow 80 GPM
Electrical 208-230V 3 Phase
Tank Required 20 Gallon
Model Number 17084V240Y-3
Max Flow 240 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon
Model Number 17084V160Y-1
Max Flow 160 GPM
Electrical 208-230V 1 Phase
Tank Required 52 Gallon Minimum
Model Number 17084V160Y-3
Max Flow 160 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Triplex
Technical Information - Duplex
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19242
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - 17088V140Y Simplex / 17088V280Y Duplex17088V420Y Triplex Technical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
Max Boost 88 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 213TC
Horsepower 7 1/2
Seal Material Carbon/Sic
Electrical 208-230V 3 Phase
Base 304 Stainless Steel
Model Number 17088V140Y-3
Max Flow 140 GPM
Tank Required 36 Gallon
Model Number 17088V280Y-3
Max Flow 280 GPM
Tank Required 52 Gallon Minimum
Model Number 17088V420Y-3
Max Flow 420 GPM
Tank Required 86 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Duplex
Technical Information - Triplex
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
Flow GPM
Pres
sure
PSI
100
90
80
70
60
50
40
30
20
10
0
17088V140Y Simplex / 17088V280Y Duplex / 17088V420Y Triplex
Duplex
Simplex
0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480Triplex
DuraMACTM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 243
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - 17104V080Y Simplex / 17104V160Y Duplex17104V240V Triplex Technical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
Max Boost 104 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 184TC
Horsepower 5
Seal Material Carbon/Sic
Base 304 Stainless Steel
Model Number 17104V080Y-1
Max Flow 80 GPM
Electrical 208-230V 1 Phase
Tank Required 20 Gallon
Model Number 17104V080Y-3
Max Flow 80 GPM
Electrical 208-230V 3 Phase
Tank Required 20 Gallon
Model Number 17104V240Y-3
Max Flow 240 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon
Model Number 17104V160Y-1
Max Flow 160 GPM
Electrical 208-230V 1 Phase
Tank Required 52 Gallon Minimum
Model Number 17104V160Y-3
Max Flow 160 GPM
Electrical 208-230V 3 Phase
Tank Required 52 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Triplex
Technical Information - Duplex
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80
0 20 40 60 80 100 120 140 160
Flow GPM
Pres
sure
PSI
120
110
100
90
80
70
60
50
40
30
20
10
0
17104V080Y Simplex / 17104V160Y Duplex / 17104V240Y
Duplex
Simplex
0 30 60 90 120 150 180 210 240Triplex
DuraMACTM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19244
DuraMACTM Booster PumpsDu
raM
ACTM
Boo
ster
Pum
ps
DuraMACTM - 17142V120Y Simplex / 17142V240Y Duplex17142V360Y Triplex Technical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
Max Boost 142 PSI
Suction Transducer 0-150 PSI 4-20mA
Discharge Transducer 0-150 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 215TC
Horsepower 10
Seal Material Carbon/Sic
Electrical 208-230V 3 Phase
Base 304 Stainless Steel
Model Number 17142V120Y-3
Max Flow 120 GPM
Tank Required 32 Gallon
Model Number 17142V240Y-3
Max Flow 240 GPM
Tank Required 52 Gallon Minimum
Model Number 17142V360Y-3
Max Flow 360 GPM
Tank Required 86 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Duplex
Technical Information - Triplex
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80 90 100 110 120 130
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Pres
sure
PSI
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
17142V120Y Simplex / 17142V240Y Duplex / 17142V360Y Triplex
Duplex
Simplex
0 30 60 90 120 150 180 210 240 270 300 330 360 390Triplex
DuraMACTM
-
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 245
DuraMACTM Booster PumpsDuraM
ACTM Booster Pum
ps
DuraMACTM - 17150V080Y Simplex / 17150V160Y Duplex 17150V240Y TriplexTechnical Information & Performance Curves
A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.
Max Boost 150 PSI
Suction Transducer 0-200 PSI 4-20mA
Discharge Transducer 0-200 PSI 4-20mA
Drive - Yaskawa iQ Pump NEMA 1
Suction Ball Valve 2” No-Lead Brass
Discharge Ball Valve 2” No-Lead Brass
Impeller 304 Stainless Steel
Pump End 304 Stainless Steel
Motor - Energy Eff. TEFC 213TC
Horsepower 7 1/2
Seal Material Carbon/Sic
Electrical 208-230V 3 Phase
Base 304 Stainless Steel
Model Number 17150V080Y-3
Max Flow 80 GPM
Tank Required 20 Gallon
Model Number 17150V160Y-3
Max Flow 160 GPM
Tank Required 52 Gallon Minimum
Model Number 17150V240Y-3
Max Flow 240 GPM
Tank Required 52 Gallon Minimum
Technical Information Technical Information - Simplex
Technical Information - Duplex
Technical Information - Triplex
60 Hz Pump Performance
0 10 20 30 40 50 60 70 80
0 20 40 60 80 100 120 140 160
Flow GPM
Pres
sure
PSI
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
17150V080Y Simplex / 17150V160Y Duplex17150V240Y Triplex
Duplex
Simplex
0 30 60 90 120 150 180 210 240Triplex
DuraMACTM