well pump systems - duramactm booster pumpsduramactm model pump boost amps length “l” voltage...

33
1-19 213 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com Jet Pumps Jet Pumps DuraMAC TM Booster Pumps Pump Catalog - January 2019 MORE THAN A BRAND. WE’RE A FAMILY. DuraMAC TM Booster Pumps

Upload: others

Post on 26-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • 1-19 213800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com

    Jet PumpsJet Pum

    ps

    DuraMACTM Booster Pumps

    Pump Catalog - January 2019

    MORE THAN A BRAND. WE’RE A FAMILY.

    DuraMAC

    TM Booster Pumps

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19214

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    Typical InstallationsNot all boosting applications require complicated boosting systems. The DuraMACTM Booster System is simple, versatile, sophisticated, and reliable. Quite simply, it is the World’s Most Versatile Boosting System.

    VersatileIt is the first booster pump of its kind to be designed for virtually all boosting applications. In Pressure Mode, the pump starts with pressure drop and stops on low flow. In Flow Mode, the pump starts and stops by sensing flow. In Conservation Mode, the pump only operates during a peak demand, such as when multiple showers, bathtubs, or irrigation systems are running.

    SimpleA single-speed, totally enclosed fan-cooled motor drives the DuraMAC™ booster pump with single phase power. It is controlled with one dial and tells you it is working properly by illuminating a single status light. The settings and readouts are simple and straight forward.

    SophisticatedA pressure transducer constantly monitors system pressure and alerts the pump control to start the pump as water in the system is used. The pump then stays on, boosting the system pressure until the need for water is no longer present, indicated by low flow.

    ReliableElectronic components are completely separated from piping and water ways for added safety and ease of field repair. The DuraMAC™ is built from scratch with one purpose in mind - boosting water pressure. Each component of the system is specifically designed to work together, as one harmonious unit.

    STAND PIPE

    PRIME PLUG

    FOOT VALVE

    OUTLET

    SUCTION PIPE

    VALVE

    PUMP FILL PLUG

    OUTLET

    INLET

    UNION

    PUMP FILL PLUG

    VALVE

    CHECK VALVEUNION

    PRESSURE REDUCING VALVE(SEE INSTRUCTIONS)

    VALVE

    BYPASS VALVECLOSED

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 215

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    The World’s Most Versatile Booster SystemPressure TankEliminates short cycling and helps accommodate thermal expansion.

    Pressure GaugeDisplays total system pressure

    Circuit BoardSophisticated programming assures proper operation in all conditions.

    Digital ControlSingle knob for simple pressure adjustment. Status light indicates standby, run and fault modes

    TransducerConstantly monitors system pressure.

    Inlet w/Check Valve: ResidentialNo-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections

    Inlet w/Check Valve: Light CommercialNo-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections

    Union SwivelAllows for 360o adjustment of discharge.

    MotorTotally enclosed fan-cooled motor for quiet operation and low power consumption

    PumpAll stainless construction for tough water conditions.

    Dual-Mode Modular, Simplex, & Duplex

    Vertical Multistage Variable Speed

    Simplex & Duplex Boosters

    E-Series, Residential, Light Commercial,

    & Irrigation Boosters

    A.Y. McDonald’s Full Line of DuraMACTM Booster Pumps

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19216

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    How to OrderOrder by Model Number - Example: 17044C070PC2-M

    P C 2 - M17 044 C 070Series1718

    Water Pressure at 0 GPM035040044052060062070078

    TypeR - ResidentialC - Commercial

    OptionsD - DuplexM - ModularS - Simplex

    SS - Stainless Steel*Only available in E-Series

    GPM020035070120

    Voltage1 - 120V2 - 230V

    Models Available - Residential, Light Commercial, & Irrigation Boosters 17035R020PC1 17040C035PC2 17052R020PC1 17062C035PC2 17070R020PC2 17078C035PC2

    Models Available - E-Series

    18035R020PC1 18052R020PC1

    Models Available - Dual-Mode - Modular, Simplex, & Duplex Models 17044C070PC2-S 17060C070PC2-M 17060C070PC2-S 17044C120PC2-D 17044C070PC2-M 17060C120PC2-D

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 217

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    The DuraMACTM Water Pressure Boosting System can be set to three separate modes, which can accommodate virtually any application.

    New Pump Control 115V115V DC: B17 - Current230V DC: F17 - Current

    How It Works

    DuraMACTM Residential, Light Commercial, & Irrigation Pump Control(excludes E-Series)

    PRESSURE MODE START METHOD: Pressure drop STOP METHOD: Low flow TYPICAL INSTALLATION: Appropriate for the majority of light commercial or residential applications RESULT: Pump operates continuously while there is a need for water

    FLOW MODE START METHOD: Water flow STOP METHOD: Low flow TYPICAL INSTALLATION: Application where pressure fluctuates, or occasional system leaks are present RESULT: Pump operates when usage of water exceeds approximately one gallon per minute

    CONSERVATION MODE START METHOD: Pressure drop

    STOP METHOD: Low Flow

    TYPICAL INSTALLATION: Application where pressure is adequate for most uses, and boosting is only necessary for high demand

    RESULT: Pump will operate only when system pressure is below city supplied pressure and operate continuously while there is demand for water

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19218

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM Booster PumpNot all boosting applications require complicated boosting systems. The DuraMAC™

    Boosting system is simple, versatile, sophisticated, and reliable. With an easy set-up installation and a versatile control with three modes of operation, this pump is exible enough to meet your commercial or irrigation needs.

    The 304 stainless steel version of the DuraMAC™ Booster pump will meet the needs of boosting water pressure from Reverse Osmosis (RO) systems, low PH and other agressive water applications which would be corrosive to no-lead brass and metal pipes.

    Features:- Water pressure boosting system for residential, irrigation, or light commercial use

    - Easy set-up installation

    - All metal connections - no plastic threads

    - Half-gallon pressure tank included

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - No-Lead Brass / 304 stainless steel check valve included

    - Dry-Run protection

    - 1” inlet and outlet

    - 1 year warranty

    Models AvailableDuraMACTM Model

    Pump Boost Amps Voltage Power Weight

    18035R020PC1 35 PSI 5.5 120 - 60 Hz 1/2 HP 27.118052R020PC1 52 PSI 7.0 120 - 60 Hz 3/4 HP 27.718035R020PC1SS 35 PSI 5.5 120 - 60 Hz 1/2 HP 27.118052R020PC1SS 52 PSI 7.0 120 - 60 Hz 3/4 HP 27.7

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass / Stainless Steel - Pump Controller Cross No-Lead Brass / Stainless Steel

    80

    70

    60

    50

    40

    30

    20

    10

    00 5 10 15

    Flow GPM

    DuraMACTM Performance (Additional Boost)

    Pres

    sure

    PSI

    20

    18052R020PC1

    18035R020PC1PSI+35

    +52PSI

    s. The DuraMAC™

    With an easy set-n, this pump is

    Pric

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 219

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    E-Series DuraMACTM Booster Pump

    Typical Installation

    Sizing InformationE-Series DuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump total pressure boost should be added to current household system pressure to determine total system pressure when boosted. Note: It is not recommended to exceed 80 PSI total boosted household pressure.

    Example:Household system pressure before boost = 30 PSI

    30 + = Household Total Pump Total Pressure Pressure Pressure After Boost

    Models Available: Boost18035R020PC1 +3518052R020PC1 +52

    30 + 35 = 65 Household Total Pump Total Pressure Pressure Pressure After Boost

    *Not Recommended to Exceed 80 PSI

    Based on this example, the recommended model for this application is the 18035R020PC1. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.

    Total static pressure DuraMAC™ pumpSizing Chart

    Dimensional Information

    +35PSI

    +52PSI

    CONTACT FACTORY

    Incoming 18035R020PC1 18052R020PC1 Pressure (PSI) 60 55 90 50 85 45 80 40 75 35 70 87 30 65 82 25 60 77 20 55 72 15 50 67 10 45 62

    OUTLET

    INLETVALVE

    PRESSURE REDUCING VALVE(WELL SYSTEMS SET 20-30 PSI)

    (CITY SUPPLY - READ INSTRUCTIONS)RECOMMENDED FOR SOME

    BYPASS VALVE CLOSED

    UNION

    GAUGE - RECOMMENDED

    CHECK VALVE

    VALVE

    UNION

    120VAC

    60HZ 10

    FLA 60

    LRA

    PUMP ST

    ARTS ON

    PRESSU

    RE OR FL

    OW

    GREEN - S

    TANDBY

    RED - LOW

    PRESSUR

    EBLUE

    - RUN

    PUMP ST

    OPS ON

    LOW FLO

    W

    WWW.AY

    MCDONA

    LD.COM

    INDOOR

    USE ONL

    YNEMA 1

    15300PC

    DuraMAC

    TM E-Series

    PUMP CO

    NTROL

    CITY OR WELL SUPPLY

    SUCTION LIFT

    120VAC 60HZ

    10 FLA 60 L

    RA

    PUMP STARTS

    ON PRESSUR

    E OR FLOW

    GREEN - STANDB

    Y

    RED - LOW PRES

    SUREBLUE - RU

    N

    PUMP STOPS

    ON LOW FLOW

    WWW.AYMCD

    ONALD.COM

    INDOOR USE

    ONLYNEMA 115300

    PC DuraMAC

    TM E-Series PUMP

    CONTROL

    SUCTION PIPE

    OUTLET

    FOOT VALVE

    PRIME PLUG

    STAND PIPECHECKVALVE

    GAUGE - RECOMMENDED

    10 Ft. Max

    4.25"

    3.5"

    5.5" 3.5"4.0"

    16.5"

    4.0"

    5.25"

    120VAC 60HZ 10 FLA 60 LRA

    GREEN - STANDBY

    RED - LOW PRESSUREBLUE - RUN

    15300PC DuraMACTM E-Series PUMP CONTROL

    PUMP STOPS ON LOW FLOWWWW.AYMCDONALD.COM INDOOR USE ONLY

    NEMA 1

    PUMP STARTS ON PRESSURE OR FLOW

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19220

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Residential BoosterNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world’s most versatile boosting system for residential use.

    Features:- Easy set-up installation

    - Digital control for three modes of operation

    - Durable stainless steel and no-lead brass connections

    - Two gallon pressure tank included

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - Pressure gauge included

    - No-Lead brass check valve included

    - Dry-Run protection

    20 Gallon / Minute (GPM) MaxDuraMACTM Model

    Pump Boost Amps

    Length “L” Voltage Power

    *Pressure Reducing Valve Recommended for installation with incoming pressure greater than: Wt.

    17035R020PC1 35 PSI 5.5 15.26” 120 - 60 Hz 1/2 HP 45 PSI 33

    17052R020PC1 52 PSI 7.0 15.97” 120 - 60 Hz 3/4 HP 28 PSI 37

    17070R020PC2 70 PSI 4.0 16.68” 230 - 60 Hz 1 HP 10 PSI (for use with holding tank) 40

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    17070R020PC2

    80

    70

    60

    50

    40

    30

    20

    10

    00 5 10 15 20

    17052R020PC1

    17035R020PC1PSI+35

    PSI+70

    +52PSI

    Pres

    sure

    PSI

    Flow GPM

    DuraMACTM Performance Curve (Additional Boost)

    *Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure.

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 221

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Residential Booster

    Incoming 17035R020PC1 17052R020PC1 17070R020PC2 Pressure (PSI)

    60 55 90 50 85 45 80 40 75 35 70 87 30 65 82 25 60 77 20 55 72 90 15 50 67 85 10 45 62 80

    Typical Installation

    Sizing InformationDuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted.

    Example:Household system pressure before boost = 30 PSI

    30 + = Household Total Pump Total Pressure Pressure Pressure After Boost

    Models Available: Boost17035R020PC1 +3517052R020PC1 +5217070R020PC2 +70

    30 + 35 = 65 Household Total Pump Total Pressure Pressure Pressure After Boost

    *Not Recommended to Exceed 80 PSI

    Based on this example, the recommended model for this application is the 17035R020PC1. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.

    25”

    3.5”

    11.2”

    8”

    ADD AND MEASURE AIR PRESSURE HERENOTE: WATER PRESSURE MUST BE 0 PSI WHEN ADJUSTING AIR PRESSURE

    *L

    4” 5.5”

    4.25”

    1"Male NPT

    Check Valve

    1"Female NPT

    3.5”

    11.2”

    8”

    4.25”

    +35 +52 +70

    Total static pressure DuraMAC™ pump

    CONTACT FACTORY

    Sizing Chart

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass - Pump Controller Cross No-Lead Brass

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19222

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Light Commercial & IrrigationNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With an easy set-up installation and a versatile control with three modes of operation, this pump is exible enough to meet your commercial or irrigation needs.

    Features:- Easy set-up installation

    - Digital control for three modes of operation

    - Durable stainless steel and no-lead brass connections

    - Two gallon pressure tank included

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - Pressure gauge included

    - No-Lead brass check valve included

    - Dry-Run protection

    35 Gallon / Minute (GPM) MaxDuraMACTM Model

    Pump Boost Amps

    Length “L” Voltage Power

    *Pressure Reducing Valve Recommended for installation with incoming pressure greater than: Wt.

    17040C035PC2 40 PSI 5.0 15.43” 230 - 60 Hz 1 HP 40 PSI 38

    17062C035PC2 62 PSI 6.3 16.49” 230 - 60 Hz 1 HP 18 PSI 41

    17078C035PC2 78 PSI 6.8 17.55” 230 - 60 Hz 1 1/2 HP 2 PSI (for use with holding tank) 35

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    17078C035PC2

    0 5 10 15

    80

    70

    60

    50

    40

    30

    20

    10

    020 25 30 35

    17062C035PC2

    17040C035PC2PSI+40

    PSI+78+62PSI

    DuraMACTM Performance Curve (Additional Boost)

    Pres

    sure

    PSI

    Flow GPM

    *Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure.

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 223

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Light Commercial & Irrigation

    Typical Installation

    Sizing InformationDuraMAC™ Booster Systems are designed to shut off when no ow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted.

    Example:Household system pressure before boost = 30 PSI

    30 + = Household Total Pump Total Pressure Pressure Pressure After Boost

    Models Available: Boost17040C035PC2 +4017062C035PC2 +6217078C035PC2 +78

    30 + 40 = 70 Household Total Pump Total Pressure Pressure Pressure After Boost

    *Not Recommended to Exceed 80 PSI

    Based on this example, the recommended model for this application is the 17040C035PC2. For systems with uctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80 PSI.

    Total static pressure DuraMAC™ pumpSizing Chart

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Check Valve No-Lead Brass - Pump Controller Cross No-Lead Brass

    +40PSI

    +62PSI

    +78PSI

    CONTACT FACTORY

    Incoming 17040C035PC2 17062C035PC2 17078C035PC2 Pressure (PSI) 60 55 50 90 45 85 40 80 35 75 30 70 25 65 87 20 60 82 15 55 77 93 10 50 72 88

    25"

    ADD AND MEASURE AIR PRESSURE HERE NOTE: WATER PRESSURE MUST BE 0 PSI WHEN ADJUSTING AIR PRESSURE.

    *L

    4" 5.5"

    1 1/4" FEMALE NPT

    1" FEMALE NPT10

    2030

    40 50 6070

    80

    90100PSI

    CHECK VALVE

    3.5"

    10.8"

    8"

    4.3"

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19224

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Dual Mode ModularNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With a quick and easy installation, and unique digital control featuring dual modes of operation, this pump can meet your unique commercial or irrigation needs.

    Features:- Easy set-up installation

    - Digital control with dual modes of operation

    - Durable stainless steel and no-lead brass connections

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - Pressure gauge included

    - No-Lead brass check valve included (meets no-lead compliance)

    70 Gallon / Minute (GPM) Max

    DuraMACTM Model Description

    Pump Boost Amps Voltage Power

    *Pressure Reducing Valve Recommended for installation with

    incoming pressure greater than: Wt.

    17044C070PC2-M 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 56

    17060C070PC2-M 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 56

    *Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.

    0 10 20 30

    80

    70

    60

    50

    40

    30

    20

    10

    040 50 60 70

    PSI+60

    PSI+44

    DuraMACTM Performance Curve (Additional Boost)

    Pres

    sure

    PSI

    Flow GPM

    17060C070PC2-M

    17044C070PC2-M

    See Pumps & AccessoriesPrice List for Limited Warranty details.

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 225

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Dual Mode ModularControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC

    15100PC2 DUAL~MODE

    FLOW STOP

    CC USUS

    STAND BY

    PRESSURE START PRESSURE STOP

    WWW.AYBOOSTERS.COM

    RUN FAULT

    10 PSI MIN

    TESTRESET /

    PRESSURE START

    2 PSI LESS THAN START PRESSUREAIR PRESSURE IN TANK SHOULD BE

    PUMP CONTROL

    230VAC 60HZ 8.8 FLA 48 LRA

    TM DuraMAC

    FOR INDOOR USE ONLY

    4.65"

    4.25"7.3"

    21.5"

    5.43" 4.96"15.1"

    1 1/2"NPT

    1 1/2"NPT

    CheckValve

    PSI 10090

    8070

    60504030

    20

    10

    Dual-Mode Modular Shown. Skid mounted Simplex and Duplex available.

    In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.

    This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.

    PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow

    In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.

    FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow

    10

    20

    3040

    50

    60

    700

    SET 10-15 PSI BELOWBOOSTED PRESSURE

    PUSH RESET

    START PRESSURE

    STAND BY FAULTRUNRESET

    FLOW

    PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY

    15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA

    WWW.AYBOOSTERS.COM

    TM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19226

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Dual Mode Simplex

    70 Gallon / Minute (GPM) Max

    DuraMACTM Model Description

    Pump Boost Amps Voltage Power

    *Pressure Reducing Valve Recommended for installation with

    incoming pressure greater than: Wt.

    17044C070PC2-S 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 168

    17060C070PC2-S 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 168

    *Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.

    Not all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With the ability to pump up to 70 GPM this unique pump is ideal for commercial or irrigation use.

    Features:- Easy set-up installation

    - Digital control with dual modes of operation

    - Durable stainless steel and no-lead brass connections

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - Pressure gauge included

    - No-Lead brass check valve included

    - Up to 70 GPM

    - 20 gallon pressure tank included

    - Stainless steel base

    - Dry run protection

    ms.nd eal

    0 10 20 30

    80

    70

    60

    50

    40

    30

    20

    10

    040 50 60 70

    PSI+60

    PSI+44

    DuraMACTM Performance Curve (Additional Boost)

    Pres

    sure

    PSI

    Flow GPM

    17060C070PC2-S

    17044C070PC2-S

    See Pumps & AccessoriesPrice List for Limited Warranty details.

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 227

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Dual Mode SimplexControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC - Base 304 Stainless Steel

    Simplex base mounted with 20 gallon tank.

    28"18"

    6.2"

    24.5"34"

    1 1/2" NPT

    1 1/2" NPT

    Check Valve

    In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.

    This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.

    PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow

    In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.

    FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow

    10

    20

    3040

    50

    60

    700

    SET 10-15 PSI BELOWBOOSTED PRESSURE

    PUSH RESET

    START PRESSURE

    STAND BY FAULTRUNRESET

    FLOW

    PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY

    15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA

    WWW.AYBOOSTERS.COM

    TM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19228

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Dual Mode Duplex

    120 Gallon / Minute (GPM) Max

    DuraMACTM Model Description

    Pump Boost Amps Voltage Power

    *Pressure Reducing Valve Recommended for installation with

    incoming pressure greater than: Wt.

    17044C120PC2-D 230V Booster System 44 PSI 7.0 230 - 60 Hz 2 HP 36 PSI 252

    17060C120PC2-D 230V Booster System 60 PSI 8.0 230 - 60 Hz 2 HP 20 PSI 252

    *Many plumbing codes do not recommend system pressure exceeding 80 PSI. Refer to local plumbing codes for maximum boosted pressure. Pressure tank required. See instruction manual for sizing information.

    Not all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world’s most versatile boosting system for commercial or irrigation use.

    Features:- Easy set-up installation

    - Digital control with dual modes of operation

    - Durable stainless steel and no-lead brass connections

    - TEFC single phase motor for quiet operation

    - Electronics separated and sealed from waterway

    - Pressure gauge included

    - No-Lead brass check valve included

    - Designed for Lead-Lag

    - Up to 120 GPM

    - 20 gallon pressure tank included

    - Stainless steel base

    - Dry run protectionSee Pumps & Accessories

    Price List for Limited Warranty details.

    ting tile,

    most

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    0 20 40 60 80 100 120

    70

    60

    50

    40

    30

    20

    10

    0

    PSI+60

    PSI+44

    Pres

    sure

    PSI

    Flow GPM

    DuraMACTM Performance Curve (Additional Boost - Both Pumps Running)17060C120PC2-D

    17044C120PC2-D

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 229

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Dual Mode SimplexControl FeaturesThe DuraMAC™ Dual-Mode control has the exibility to be run in two different modes.

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Union Connection No-Lead Brass - Check Valve No-Lead Brass - Pump Control No-Lead Brass - Motor - Single Phase 2 HP TEFC - Base 304 Stainless Steel

    10

    20

    3040

    50

    60

    700

    SET 10-15 PSI BELOWBOOSTED PRESSURE

    PUSH RESET

    START PRESSURE

    STAND BY FAULTRUNRESET

    FLOW

    PUMP STARTS ON PRESSUREPUMP STOPS ON LOW FLOWSTART PRESSURE INSTRUCTIONSUNDER ROUND COVERTO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESETAIR PRESSURE IN TANK SHOULD BE2 PSI LESS THAN START PRESSUREFOR INDOOR USE ONLY

    15000 PC2 DuraMAC PUMP CONTROL230VAC 60HZ 8 FLA 48 LRA

    WWW.AYBOOSTERS.COM

    TM

    Duplex base mounted with 20-gallon tank 2” NPT manifolds with ball valves.36"

    34"

    27"

    6.2"

    28.5"

    2" NPT

    Check Valve

    2" NPT

    In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the ow is less than three Gallons per Minute.

    This smart system will only run the pump when water is in use. There is a preset seven7 second delay after water is not owing past the ow sensor to fully pressurize your system and eliminate water hammer.

    PRESSURE MODESTART METHOD: Pressure DropSTOP METHOD: Low Flow

    In Flow Mode, the control will start and stop on ow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting ow rate is approximately ve Gallons per Minute. The pump will stop when the ow is less than three Gallons per Minute.

    FLOW MODESTART METHOD: Water FlowSTOP METHOD: Low Flow

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19230

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    How to Order a Vertical Multistage Simplex / Duplex / Triplex SystemOrder by Model Number - Example: 17060V140Y-34

    Y - 3 417 060 V 140Series Water Pressure

    at 0 GPM056060062084088104140142150

    Variable Speed

    GPM080120140160240280360420

    Yaskawa Drive

    Phase1 - Single Phase3 - Three Phase

    Volts4 - 460VLeave blank for 208 / 230 volts (standard)

    Models Available - Simplex Models 17062V080Y-1 17150V080Y-3 17062V080Y-3 17142V120Y-3 17084V080Y-1 17056V120Y-1 17084V080Y-3 17060V140Y-3 17104V080Y-1 17088V140Y-3 17104V080Y-3

    Models Available - Duplex Models 17062V160Y-1 17150V160Y-3 17062V160Y-3 17142V240Y-3 17084V160Y-1 17056V240Y-1 17084V160Y-3 17060V280Y-3 17104V160Y-1 17088V280Y-3 17104V160Y-3

    Models Available - Triplex Models 17062V240Y-3 17150V240Y-34 17062V240Y-34 17142V360Y-3 17084V240Y-3 17142V360Y-34 17084V240Y-34 17060V420Y-3 17104V240Y-3 17060V420Y-34 17104V240Y-34 17088V420Y-3 17150V240Y-3 17088V420Y-34

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 231

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    How It WorksThe Yaskawa iQpump 1000 drive features powerful software combined with an internal PLC to deliver multiple features that are designed help protect the drive, pump, motor, and entire pumping system. While many of these features are factory programmed and set, many features depend on the speci c pumping application and may be required to be set during install.

    Changing certain parameters while the drive and pump are running may cause unwanted behavior. It is recommended to turn the drive off before changing parameter values.

    To return to home screen, hold for 3 seconds, or press . The display should look similar to the one below. Once at the home screen, additional drive status can be viewed by pressing . Additional drive information includes output frequency, current, voltage, DC bus voltage, and kilowatts.

    Digital Operator Keypad Alarm light blinks if alarm or fault occurs.

    Pump Output Frequency

    Press to turn AUTO mode on.

    If LED is blinking, Auto mode is active but pump is sleeping.

    Transducer Feedback (Actual System Pressure)

    System Outlet Pressure Auto Setpoint

    Press to turn HAND mode on. Use only for Priming and troubleshooting. Pump will run at a xed speed.

    Do not run against a closed discharge.

    Press to turn system off.

    DuraMACTM Vertical Multistage Variable Speed Simplex / Duplex / Triplex Booster Pump Control Features

    - Set it and forget it technology- Set point at 50 PSI, but can be easily be changed in

    the eld- Extremely reliable- Proven product- Yaskawa Drive

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19232

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Simplex Booster System

    Models AvailableModel Description Pump Boost Voltage HP

    17062V080Y-1 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Single Phase 3

    17062V080Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3

    17084V080Y-1 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Single Phase 5

    17084V080Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5

    17104V080Y-1 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Single Phase 5

    17104V080Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5

    17150V080Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2

    17142V120Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10

    17056V120Y-1 56 PSI 230V VFD Booster 56 PSI 208 - 230 - Single Phase 5

    17060V140Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5

    17088V140Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2

    The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.

    Features:- Easy set-up installation

    - Variable speed control

    - Stainless steel pump

    - Energy ef cient NEMA TEFC motors

    - Liquid lled gauges

    - Wafer check valves with soft seat

    - Stainless steel base

    - 2” Brass No-Lead isolation valves

    - NEMA 1 enclosure

    - Suction and discharge transducers

    - Fused disconnect

    - 2” Suction and discharge

    - Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    460 volt version also available

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 233

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Simplex Booster SystemControl Features

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide

    - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel

    IN OUT

    CHECK VALVE

    30

    4.6

    30

    50

    - Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.

    - Date and time stamp for all faults.

    - Better system ef ciency by applying only the power needed based on the load.

    - Password protected parameter settings.

    - Real time clock.

    - No Flow Mode - puts pump to sleep during no ow conditions.

    - Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.

    - Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.

    - Live Zero protects the pump if the transducer cable is broken or damaged.

    60 Hz Pump PerformanceOne Pump Running

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160

    Flow GPM

    Pres

    sure

    PSI

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17150V080

    17104V080

    17084V080

    17062V080

    17142V120

    17088V140

    17060V140

    17056V120

    DuraMACTM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19234

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Duplex Booster System

    Models AvailableModel Description Pump Boost Voltage HP

    17062V160Y-1 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Single Phase 3

    17062V160Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3

    17084V160Y-1 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Single Phase 5

    17084V160Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5

    17104V160Y-1 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Single Phase 5

    17104V160Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5

    17150V160Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2

    17142V240Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10

    17056V240Y-1 56 PSI 230V VFD Booster 56 PSI 208 - 230 - Single Phase 5

    17060V280Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5

    17088V280Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2

    The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.

    Features:- Easy set-up installation

    - Variable speed control

    - Stainless steel pump

    - Energy ef cient NEMA TEFC motors

    - Liquid lled gauges

    - Wafer check valves with soft seat

    - Stainless steel base

    - 2” Brass No-Lead isolation valves

    - NEMA 1 enclosure

    - Suction and discharge transducers

    - Fused disconnect

    - 3” Flanged stainless steel manifolds

    - Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    460 volt version also available

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 235

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Duplex Booster SystemControl Features

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide

    - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel

    - Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.- Lead - Lag pump control to alternate pump starts, allowing equal run times on all pumps for longer life cycles.- Better system ef ciency by applying only the power needed based on the load.- Password protected parameter settings.- Real time clock.- No Flow Mode - puts pump to sleep during no ow conditions.- Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.- Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.- Live Zero protects the pump if the transducer cable is broken or damaged.- Backup system transducer for pump and drive redundancy.

    48

    31

    4.6

    46

    60 Hz Pump PerformanceBoth Pumps Running

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

    Flow GPM

    Pres

    sure

    PSI

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17150V160

    17142V240

    17088V280

    17060V280

    17056V240

    17104V160

    17084V160

    17062V160

    DuraMACTM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19236

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Triplex Booster System

    Models AvailableModel Description Pump Boost Voltage HP

    17062V240Y-3 62 PSI 230V VFD Booster 62 PSI 208 - 230 - Three Phase 3

    17084V240Y-3 84 PSI 230V VFD Booster 84 PSI 208 - 230 - Three Phase 5

    17104V240Y-3 104 PSI 230V VFD Booster 104 PSI 208 - 230 - Three Phase 5

    17150V240Y-3 150 PSI 230V VFD Booster 150 PSI 208 - 230 - Three Phase 7 1/2

    17142V360Y-3 142 PSI 230V VFD Booster 142 PSI 208 - 230 - Three Phase 10

    17060V420Y-3 60 PSI 230V VFD Booster 60 PSI 208 - 230 - Three Phase 5

    17088V420Y-3 88 PSI 230V VFD Booster 88 PSI 208 - 230 - Three Phase 7 1/2

    The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems.

    Features:- Easy set-up installation

    - Variable speed control

    - Stainless steel pump

    - Energy ef cient NEMA TEFC motors

    - Liquid lled gauges

    - Wafer check valves with soft seat

    - Stainless steel base

    - 2” Brass No-Lead isolation valves

    - NEMA 1 enclosure

    - Suction and discharge transducers

    - Fused disconnect

    - 4” Flanged stainless steel manifolds

    - Certi ed to: NSF / ANSI 61 Section 8-2016 NSF / ANSI 372-2016

    See Pumps & AccessoriesPrice List for Limited Warranty details.

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    460 volt version also available

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 237

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - Vertical Multistage Variable Speed Triplex Booster System

    60 Hz Pump PerformanceAll Pumps Running

    0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480

    Flow GPM

    Pres

    sure

    PSI

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17150V240

    17142V360

    17088V420

    17060V420

    17104V240

    17084V240

    17062V240

    DuraMACTM47

    5.6

    49

    44

    Materials of Construction - Impellers 304 Stainless Steel - Pump Casing Inlet 301 Stainless Steel - Pump Casing Outlet 301 Stainless Steel - Pump Seal (stationary) Silicon Carbide

    - Pump Seal (rotating) Carbon / NBR - Diffuser 304 Stainless Steel - Base 304 Stainless Steel

    - Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure.

    - Lead - Lag pump control to alternate pump starts, allowing equal run times on all pumps for longer life cycles.

    - Better system ef ciency by applying only the power needed based on the load.

    - Password protected parameter settings.

    - Real time clock.

    - No Flow Mode - puts pump to sleep during no ow conditions.

    - Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted.

    - Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability.

    - Live Zero protects the pump if the transducer cable is broken or damaged.

    - Backup system transducer for pump and drive redundancy.

    Control Features

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19238

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - 17056V120Y Simplex / 17056V240Y Duplex Technical Information & Performance Curves

    Max Boost 56 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 184TC

    Horsepower 5

    Seal Material Carbon/Sic

    Electrical 208-230V 1 Phase

    Base 304 Stainless Steel

    Model Number 17056V120Y-1

    Max Flow 120 GPM

    Tank Required 32 Gallon

    Model Number 17056V240Y-1

    Max Flow 240 GPM

    Tank Required 52 Gallon Minimum

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80 90 100 110 120 130

    0 20 40 60 80 100 120 140 160 180 200 220 240 260

    Flow GPM

    Pres

    sure

    PSI

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17056V120Y Simplex / 17056V240Y Duplex

    Duplex

    Simplex

    DuraMACTM

    Technical Information Technical Information - Simplex Technical Information - Duplex

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 239

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - 17060V140Y Simplex / 17060V280Y Duplex17060V420Y Triplex Technical Information & Performance Curves

    Max Boost 60 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 184TC

    Horsepower 5

    Seal Material Carbon/Sic

    Base 304 Stainless Steel

    Model Number 17060V140Y-3

    Max Flow 140 GPM

    Electrical 208-230V 3 Phase

    Tank Required 36 Gallon

    Model Number 17060V280Y-3

    Max Flow 280 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon Minimum

    Model Number 17060V420Y-3

    Max Flow 420 GPM

    Electrical 208-230V 3 Phase

    Tank Required 86 Gallon Minimum

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

    Flow GPM

    Pres

    sure

    PSI

    70

    60

    50

    40

    30

    20

    10

    0

    17060V140Y Simplex / 17060V280Y Duplex / 17060V420Y Triplex

    DuplexSimplex

    0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480Triplex

    DuraMACTM

    Technical Information Technical Information - Simplex

    Technical Information - Duplex

    Technical Information - Triplex

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19240

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM -17062V080Y Simplex / 17062V160Y Duplex17062V240Y TriplexTechnical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80

    0 20 40 60 80 100 120 140 160

    Flow GPM

    Pres

    sure

    PSI

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17062V080Y Simplex / 17062V160Y Duplex / 17062V240Y Triplex

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240Triplex

    DuraMACTM

    Max Boost 62 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 182TC

    Horsepower 3

    Seal Material Carbon/Sic

    Base 304 Stainless Steel

    Model Number 17062V080Y-1

    Max Flow 80 GPM

    Electrical 208-230V 1 Phase

    Tank Required 20 Gallon

    Model Number 17062V080Y-3

    Max Flow 80 GPM

    Electrical 208-230V 3 Phase

    Tank Required 20 Gallon

    Model Number 17062V240Y-3

    Max Flow 240 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon

    Model Number 17062V160Y-1

    Max Flow 160 GPM

    Electrical 208-230V 1 Phase

    Tank Required 52 Gallon Minimum

    Model Number 17062V160Y-3

    Max Flow 160 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Triplex

    Technical Information - Duplex

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 241

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - 17084V080Y Simplex / 17084V160Y Duplex17084V240Y Triplex Technical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80

    0 20 40 60 80 100 120 140 160

    Flow GPM

    Pres

    sure

    PSI

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17084V080Y Simplex / 17084V160Y Duplex / 17084V240Y Triplex

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240Triplex

    DuraMACTM

    Max Boost 84 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 184TC

    Horsepower 5

    Seal Material Carbon/Sic

    Base 304 Stainless Steel

    Model Number 17084V080Y-1

    Max Flow 80 GPM

    Electrical 208-230V 1 Phase

    Tank Required 20 Gallon

    Model Number 17084V080Y-3

    Max Flow 80 GPM

    Electrical 208-230V 3 Phase

    Tank Required 20 Gallon

    Model Number 17084V240Y-3

    Max Flow 240 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon

    Model Number 17084V160Y-1

    Max Flow 160 GPM

    Electrical 208-230V 1 Phase

    Tank Required 52 Gallon Minimum

    Model Number 17084V160Y-3

    Max Flow 160 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Triplex

    Technical Information - Duplex

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19242

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - 17088V140Y Simplex / 17088V280Y Duplex17088V420Y Triplex Technical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    Max Boost 88 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 213TC

    Horsepower 7 1/2

    Seal Material Carbon/Sic

    Electrical 208-230V 3 Phase

    Base 304 Stainless Steel

    Model Number 17088V140Y-3

    Max Flow 140 GPM

    Tank Required 36 Gallon

    Model Number 17088V280Y-3

    Max Flow 280 GPM

    Tank Required 52 Gallon Minimum

    Model Number 17088V420Y-3

    Max Flow 420 GPM

    Tank Required 86 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Duplex

    Technical Information - Triplex

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160

    0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320

    Flow GPM

    Pres

    sure

    PSI

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17088V140Y Simplex / 17088V280Y Duplex / 17088V420Y Triplex

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480Triplex

    DuraMACTM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 243

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - 17104V080Y Simplex / 17104V160Y Duplex17104V240V Triplex Technical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    Max Boost 104 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 184TC

    Horsepower 5

    Seal Material Carbon/Sic

    Base 304 Stainless Steel

    Model Number 17104V080Y-1

    Max Flow 80 GPM

    Electrical 208-230V 1 Phase

    Tank Required 20 Gallon

    Model Number 17104V080Y-3

    Max Flow 80 GPM

    Electrical 208-230V 3 Phase

    Tank Required 20 Gallon

    Model Number 17104V240Y-3

    Max Flow 240 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon

    Model Number 17104V160Y-1

    Max Flow 160 GPM

    Electrical 208-230V 1 Phase

    Tank Required 52 Gallon Minimum

    Model Number 17104V160Y-3

    Max Flow 160 GPM

    Electrical 208-230V 3 Phase

    Tank Required 52 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Triplex

    Technical Information - Duplex

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80

    0 20 40 60 80 100 120 140 160

    Flow GPM

    Pres

    sure

    PSI

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17104V080Y Simplex / 17104V160Y Duplex / 17104V240Y

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240Triplex

    DuraMACTM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com 1-19244

    DuraMACTM Booster PumpsDu

    raM

    ACTM

    Boo

    ster

    Pum

    ps

    DuraMACTM - 17142V120Y Simplex / 17142V240Y Duplex17142V360Y Triplex Technical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    Max Boost 142 PSI

    Suction Transducer 0-150 PSI 4-20mA

    Discharge Transducer 0-150 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 215TC

    Horsepower 10

    Seal Material Carbon/Sic

    Electrical 208-230V 3 Phase

    Base 304 Stainless Steel

    Model Number 17142V120Y-3

    Max Flow 120 GPM

    Tank Required 32 Gallon

    Model Number 17142V240Y-3

    Max Flow 240 GPM

    Tank Required 52 Gallon Minimum

    Model Number 17142V360Y-3

    Max Flow 360 GPM

    Tank Required 86 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Duplex

    Technical Information - Triplex

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80 90 100 110 120 130

    0 20 40 60 80 100 120 140 160 180 200 220 240 260

    Pres

    sure

    PSI

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17142V120Y Simplex / 17142V240Y Duplex / 17142V360Y Triplex

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240 270 300 330 360 390Triplex

    DuraMACTM

  • 800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com1-19 245

    DuraMACTM Booster PumpsDuraM

    ACTM Booster Pum

    ps

    DuraMACTM - 17150V080Y Simplex / 17150V160Y Duplex 17150V240Y TriplexTechnical Information & Performance Curves

    A.Y. McDonald considers the information on this sheet correct when published. Speci cations are subject to change with notice.

    Max Boost 150 PSI

    Suction Transducer 0-200 PSI 4-20mA

    Discharge Transducer 0-200 PSI 4-20mA

    Drive - Yaskawa iQ Pump NEMA 1

    Suction Ball Valve 2” No-Lead Brass

    Discharge Ball Valve 2” No-Lead Brass

    Impeller 304 Stainless Steel

    Pump End 304 Stainless Steel

    Motor - Energy Eff. TEFC 213TC

    Horsepower 7 1/2

    Seal Material Carbon/Sic

    Electrical 208-230V 3 Phase

    Base 304 Stainless Steel

    Model Number 17150V080Y-3

    Max Flow 80 GPM

    Tank Required 20 Gallon

    Model Number 17150V160Y-3

    Max Flow 160 GPM

    Tank Required 52 Gallon Minimum

    Model Number 17150V240Y-3

    Max Flow 240 GPM

    Tank Required 52 Gallon Minimum

    Technical Information Technical Information - Simplex

    Technical Information - Duplex

    Technical Information - Triplex

    60 Hz Pump Performance

    0 10 20 30 40 50 60 70 80

    0 20 40 60 80 100 120 140 160

    Flow GPM

    Pres

    sure

    PSI

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    17150V080Y Simplex / 17150V160Y Duplex17150V240Y Triplex

    Duplex

    Simplex

    0 30 60 90 120 150 180 210 240Triplex

    DuraMACTM