Page 1: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

SwazilandTel +268 518-4263 • Fax +268 518-5481

WestonariaTel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417

Page 2: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

INFRASET is a specialised operation within the Manufacturing Operating Group of Aveng (Africa) Limited. It was formed with the specific objective of pooling the precast concrete products of the group to provide customers with a focused range of products and services.

This streamlined presence in the industry allows INFRASET to use its heritage of excellence in the provision of concrete infrastructure products to scale new heights of service and delivery to clients.

Infrastructure products

Product innovation is key in the support of infrastructure and INFRASET has applied its extensive experience with modern technology to produce effective solutions in the form of inventive, pioneering products such as the HDPE Lined and specialised jacking pipe technology.

INFRASET Infrastructure Products are currently manufactured at 5 factories countrywide which produce a comprehensive range of reinforced concrete pipes, culverts, manholes, robust toilet structures and other custom built precast products. As part of INFRASET’s commitment to the “African Renaissance”, INFRASET products are also manufactured at factories in neighbouring countries, INFRASET Swazi in Swaziland and INFRASET Zambia Limited in Zambia, Kwena INFRASET in Botswana and Fort Concrete in Zimbabwe. INFRASET is committed to maintaining the highest standards of innovation, quality and service, fulfilling the most demanding of requirements and meeting the needs of a range of projects that provide infrastructure to Africa, and the world.

Page 3: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

Precast Concrete Pipes Technical DataMaximum Fill Heights on PipesOgee Joint PipesSpigot and Socket Joint PipesSewer Pipe with Sacrificial LayerIn-the-wall Joint PipesIn-the-wall Jacking Pipes

Precast Concrete CulvertsTechnical DataMaximum Fill Heights on CulvertsRectangular Portal CulvertsRibbed Skew Haunch Culverts Culvert BasesJacking Box Culverts

Precast Concrete Manholes6-Way Concrete BaseComponentsType 2A & 2C Concrete LidsManhole ConfigurationsKerb Inlet (Catchpit)

Associated Precast Concrete ProductsChannels and DrainsAir Valve Chamber and Ore Pass LinerMedian BarriersSump/Pump Stations ChamberToiletsPrecast Wash ThroughsBus SheltersProduct Ranges

Flow Chart for Circular Pipes

22579

111314

16161921232526

2727283031

343435363738394041

42

CONTENTS

Page 4: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

2

Introduction

Infraset manufactures reinforced concrete pipes using two well-known production processes: roller suspension and automated vertical casting using high strength, high durability concrete. Both these processes are used worldwide and are acknowledged to be ideal for concrete pipe manufacturing.

All the manufacturing processes are done under carefully controlled conditions using advanced technology and equipment. These processes provide flexibility for the manufacturing of tailormade wall thicknesses for special load and strength requirements.

If corrosion problems are anticipated, Infraset has several methods of prolonging the life of the concrete pipe. The substitution of the siliceous aggregates with calcareous aggregates results in the extended life of the concrete pipe. An HDPE liner can alter-natively be added to the bore of the pipe to prevent the sulphuric acids from coming into contact with the concrete surface.

CLASSIFICATION OF PIPES

Types of pipe

Infraset offers a large range of pipes readily available in nominal lengths of 2.5m and also half-lengths on special arrangement.

Pipes ranging from Ø300 to Ø1800 with Interlocking ogee joints, Ø300 to Ø1800 pipes with Spigot and Socket joints and Ø900 to Ø1800 pipes with In-the-Wall joints are all produced in three strength classes.

Jacking pipes are manufactured only in class 100D and vary in size from Ø840 to Ø2500. Stronger pipes capable of carrying higher D-loads are manufactured on request.

All Infraset pipes bear the SANS mark and are designed, manufactured and tested in accordance with SANS 677.

SC (Stormwater Culvert) pipes are manufactured with a non-watertight, interlocking ogee joint.

The sewer and irrigation (SI) pipes are manufactured using dolomitic aggregates and have a watertight Spigot and Socket or In-the-Wall joint. Sewer pipes with a sacrificial layer (WSL) are manufactured to the SABS 1200 LD requirements with an additional 15mm cover for pipes ranging from Ø300 to Ø1050 and 20mm for pipes Ø1200 – Ø1800. T2 and T4 pressure pipes, tested to 2 and 4 bar respectively are available on request.

Spigot and Socket and In-the-Wall joint pipes are joined and sealed using either a rolling rubber or a sliding rubber ring respectively. The sliding rubber ring is installed using a soft soap lubricant.

Types of joints

Interlocking Ogee Joint Spigot & Socket Joint Butt Joint In-the-Wall Joint

PRECAST CONCRETE PIPES – TECHNICAL DATA

Page 5: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

3

Strength of pipes

Two strength tests are done on Infraset pipes. The first is a crushing test on both the SC and SI pipes, and the second is a hydraulic pressure test only on the SI pipes. The two edge-bearing crushing test is done to a proof load and also to an ultimate load 25% greater than the proof load. The proof load is determined by the class of pipe multiplied by the nominal diameter of the pipe. The proof load test can be defined as a line load that a pipe must resist without the development of crack widths exceeding 0.25mm over a length of more than 300mm. The ultimate load is the maximum line load that the pipe must support in the same test.

Load classifications

Note: D = Nominal Diameter in metres.Example: A 1500mm 75D pipe must resist: Proof Load = 75 x 1.5 = 113 kN/m Ultimate Load = 75 x 1.5 x 1.25 = 140 kN/m

All SI pipes are tested to 1,4 bar and passes the test if the pipe withstands the pressure for at least two minutes without any sign of leakage.

Loads on pipes

Working loads on pipes consist of primary and secondary loads. The primary loads that the pipes must carry are; the mass of earth fill above the pipe, traffic loading and internal pressures. The secondary loads result from soil movement and temperature effects that influence the pipe line. These secondary loads are accommodated by the flexible pipe joints.

Earth loads are determined using the Marston and Spangler theory and are dependant upon the type of installation, type of backfill material and height of fill. The two installation conditions are trench and embankment.

Traffic loads are dependant upon the wheel loads, spacing and contact areas, and the distribution of these through the fill. The standard traffic loads applicable to national highways are given in the TMH7: Code of practice for the design of highway bridges and culverts in South Africa. Infraset pipes are designed for a NB36 load, which equals an axle load of 360 kN or a 90 kN wheel load. The effective contact area of the load is a square of size 0.3m x 0.3m.

Bedding factor refers to the amount by which the bedding enhances the load-carrying capacity of the pipe. The bedding factor is defined as the ratio between the supporting strength of the buried pipe to the strength of the pipe as determined in the two-edge bearing test. The bedding of a pipe consists of a cradle of granular material underneath the pipe, which supports it and transfers the load to the foundation. Bedding factors are divided into four classes and are determined by the angle of support and type of the bedding material.

PRECAST CONCRETE PIPES – TECHNICAL DATA

50D 50 x D 50 x D x 1.25 0.149 13.2 775D 75 x D 75 x D x 1.25 0.255 21.8 7

100D 100 x D 100 x D x 1.25 0.425 36.0 7

Wolf ACSR 18.13 0.726 69.2 37Bear ACSR 23.45 1.213 111.1 37

7/3.35 Steel 10.23 0.496 67.9 77/4.0 Steel 12.24 0.712 96.8 7

19/2.65 Steel 13.55 0.849 114 19

Class of Pipe Proof Load Ultimate Load Weight per m(kg/m)

Ultimate tensilestrength (kN)

Total strands

Page 6: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

4

PRECAST CONCRETE PIPES – TECHNICAL DATA

A 2.8 3.8 120 13.2 7B 2.0 2.5 180 21.8 7C 1.5 2.0 90 36.0 7

D 1.1 N/A 0 69.2 37

Bear ACSR 23.45 1.213 111.1 377/3.35 Steel 10.23 0.496 67.9 77/4.0 Steel 12.24 0.712 96.8 7

19/2.65 Steel 13.55 0.849 114 19

Class Trench Embankment Bedding Angle Ultimate tensilestrength (kN)

Total strands

Bedding Angle

Standard bedding classes and factors

Installation conditions

Trench condition occurs when the pipe is placed in a trench cut into natural ground level and then backfilled with suitable material.

Trench condition: Class-B Trench condition: Class-C

In the embankment condition the pipe is installed at ground level and is backfilled with suitable material.

Embankment condition: Class B Embankment condition: Class C

The following tables give the pipe strength requirements in terms of D-Loads for pipes laid in a trench condition, with trench widths as per SANS 1200DB, and in embankment condition, both with NB36 traffic loading. These tables meet the D-Load requirements for general site conditions.

Page 7: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

5

Required D-Load pipe for a Class-B bedding in a Trench with TMH7 traffic loading

Required D-Load pipe for a Class-C bedding in a Trench with TMH7 traffic loading

Design criteria:1. Granular backfill material kµ = 0.16502. Soil Density = 20 kN/m3

3. Projection Ratio P = 0.94. Settlement Ratio rsd = 0.7

PRECAST CONCRETE PIPES – MAXIMUM FILL HEIGHTS ON PIPES

Nom.Dia.

PipeOD

Trenchwidth

Height of backfill above top of pipe (m)

225 280 0.88 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100

300 368 0.97 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 100 100 100 100 100 100

375 460 1.06 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 100 100

450 536 1.14 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 75

525 629 1.22 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 75

600 700 1.30 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 75

675 795 1.40 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 75

750 874 1.67 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 100 100 100 100 100

825 952 1.76 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 100 100 100 100 100

900 1035 1.84 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 75 100 100 100 100 100

1050 1185 2.20 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

1200 1340 2.37 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

1350 1500 2.52 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

1500 1670 2.69 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

1650 1830 2.88 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

1800 2003 3.02 50 50 50 50 50 50 50 50 50 50 75 75 75 75 75 100 100 100 100 100 100

(mm) (mm) (m) 0.3 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0

Nom.Dia.

PipeOD

Trenchwidth

Height of backfill above top of pipe (m)

225 280 0.88 75 50 50 50 50 50 50 75 75 100 100 100 100 100 100 100 125 125 125 125 125

300 368 0.97 75 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 100 100 100 100

375 460 1.06 75 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100 100

450 536 1.14 75 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100 100

525 629 1.22 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100

600 700 1.30 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100

675 795 1.40 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 100 100 100 100 100

750 874 1.67 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 100 100 125

825 952 1.76 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 100 100 125

900 1035 1.84 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 100 100 125

1050 1185 2.20 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 125 125 125 125

1200 1340 2.37 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 125 125 125 125

1350 1500 2.52 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 125 125 125 125

1500 1670 2.69 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 125 125 125

1650 1830 2.88 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 125 125 125

1800 2003 3.02 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 100 100 125 125 125

(mm) (mm) (m) 0.3 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0

Page 8: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

6

Required D-Load pipe for a Class-B bedding in a Embankment with TMH7 traffic loading

Required D-Load pipe for a Class-C bedding in a Embankment with THM7 traffic loading

Design criteria:1. Granular backfill material kµ = 0.16502. Soil Density = 20 kN/m3

3. Projection Ratio P = 0.94. Settlement Ratio rsd = 0.7

PRECAST CONCRETE PIPES – MAXIMUM FILL HEIGHTS ON PIPES

Nom.Dia.

PipeOD

Height of backfill above top of pipe (m)

225 280 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 150 150 150 150

300 368 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150 150

375 460 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150 150

450 536 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 125 125 150 150 150

525 629 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

600 700 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

675 795 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

750 874 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

825 952 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

900 1035 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 125 150 150

1050 1185 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 125 125 125 150

1200 1340 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 125 125 125 150

1350 1500 50 50 50 50 50 50 50 50 50 75 75 75 100 100 100 100 100 125 125 125 150

1500 1670 50 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 150

1650 1830 50 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 150

1800 2003 50 50 50 50 50 50 50 50 50 75 75 75 75 100 100 100 100 125 125 125 150

(mm) (mm) 0.3 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0

Nom.Dia.

PipeOD

Height of backfill above top of pipe (m)

225 280 75 50 50 50 50 50 75 75 75 100 100 100 125 125 150 150 150 150 175 175 200

300 368 75 50 50 50 50 50 75 75 75 100 100 100 125 125 150 150 150 150 175 175 200

375 460 75 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 175 175 175

450 536 75 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 175 175 175

525 629 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 150 150 150 150 175 175

600 700 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 150 150 150 150 175 175

675 795 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 150 150 150 150 175 175

750 874 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 125 150 150 150 175 175

825 952 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 125 150 150 150 175 175

900 1035 50 50 50 50 50 50 50 75 75 75 100 100 100 125 125 125 150 150 150 175 175

1050 1185 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 150 150 150 175 175

1200 1340 50 50 50 50 50 50 50 75 75 75 100 100 100 100 125 125 150 150 150 175 175

1350 1500 50 50 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 150 175

1500 1670 50 50 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 150 175

1650 1830 50 50 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 150 175

1800 2003 50 50 50 50 50 50 50 50 75 75 100 100 100 100 125 125 150 150 150 150 175

(mm) (mm) 0.3 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0

Page 9: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

7

OG Class 50D - SABS 677 Type SC

OG Class 75D - SABS 677 Type SC

PRECAST CONCRETE PIPES – OGEE JOINT PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

300 308 368 30 13 210 15.0

375 388 460 36 14 318 18.8

450 460 536 38 15 440 22.5

525 523 629 53 15 620 26.3

600 614 700 43 24 620 30.0

675 685 795 55 25 860 33.8

750 760 874 57 27 940 37.5

825 832 952 60 27 1080 41.3

900 915 1035 60 30 1236 45.0

1050 1030 1185 78 31 1800 52.5

1200 1170 1340 85 33 2360 60.0

1350 1300 1500 100 36 2029 67.5

1500 1460 1670 105 40 3580 75.0

1650 1585 1830 123 40 4440 82.5

1800 1735 2003 134 42 5090 90.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

300 308 368 30 13 210 22.5

375 388 460 36 14 318 28.1

450 460 536 38 15 459 33.8

525 523 629 53 15 635 39.4

600 600 700 50 24 620 45.0

675 685 795 55 25 950 50.6

750 738 874 68 27 1100 56.3

825 800 952 76 27 1373 61.9

900 880 1035 78 30 1540 67.5

1050 1030 1185 78 31 1850 78.8

1200 1143 1340 99 33 2740 90.0

1350 1280 1500 110 36 3240 101.3

1500 1420 1670 125 40 4200 112.5

1650 1585 1830 123 40 4520 123.8

1800 1735 2003 134 42 5426 135.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

Page 10: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

8

OG Class 100D - SABS 677 Type SC

Heavy Duty ‘D’ load pipes for deep fills

NOTE: 125D if required will have the same dimensions as 150D 175D if required will have the same dimensions as 200D

Nominal length 2,5mPipes available in half lengths by arrangement.Details of larger diameter pipes available on request.Dimensions and thus the mass of the pipes are subject to change without notice.For details of pipes from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE PIPES – OGEE JOINT PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

225 216 280 32 12 160 22.5

300 308 368 30 13 210 30.0

375 365 460 48 14 394 37.5

450 460 536 38 15 381 45.0

525 523 629 53 15 614 52.5

600 574 700 63 24 852 60.0

675 669 795 63 25 975 67.5

750 738 874 68 27 1154 75.0

825 776 952 88 27 1596 82.5

900 860 1035 88 30 1738 90.0

1050 991 1185 97 31 2205 105.0

1200 1120 1340 110 33 2810 120.0

1350 1250 1500 125 36 3540 135.0

1500 1400 1670 135 40 4282 150.0

1650 1525 1830 153 40 5278 165.0

1800 1640 2003 182 42 6811 180.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Pipe class Actual internaldiameter

Outside diameter

Wall thickness

Lengths Mass per metre

Total massper length

450 200D 382 526 72 2.50 266 665

600 150D 524 684 80 2.50 387 968

600 200D 494 684 95 2.50 451 1128

750 150D 680 870 95 2.50 589 1473

750 200D 620 870 125 2.50 754 1885

900 150D 810 1040 115 2.50 865 2163

900 200D 750 1040 145 2.50 1046 2615

1050 150D 930 1200 135 2.50 1150 2875

1050 200D 890 1200 155 2.50 1305 3263

1200 150D 1090 1380 145 2.50 1433 3583

1200 200D 1030 1380 175 2.50 1698 4245

1350 150D 1220 1550 165 2.50 1831 4578

1350 200D 1160 1550 195 2.50 2129 5322

1500 150D 1335 1695 180 2.50 2200 5500

1500 200D 1285 1695 205 2.50 2462 6155

2500 150D 2350 2950 300 2.00 6500 13000

(mm) (mm) (mm) (m)

Page 11: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

9

S & S Class 50D - SABS 677 Type SC or SI

* Vertical cast

S & S Class 75D - SABS 677 Type SC or SI

* Vertical cast

PRECAST CONCRETE PIPES – SPIGOT AND SOCkET JOINT PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 215 295 40 378 150 100 123 11.3

300 292 368 38 464 222 114 277 15.0

375 369 445 38 540 235 127 356 18.8

450 445 533 44 641 257 127 500 22.5

525 514 616 51 730 263 131 659 26.3

600 599 699 50 826 295 138 755 30.0

675 685 787 51 920 318 139 883 33.8

750 762 870 54 1016 329 139 1046 37.5

825 818 946 64 1086 329 139 1295 41.3

900 913 1041 64 1194 363 139 1452 45.0

1050 1034 1194 80 1352 391 162 2026 52.5

1200 1187 1365 89 1543 424 168 2566 60.0

1350 1328 1524 98 1708 442 175 2913 67.5

1500 1491 1689 99 1886 486 190 3300 75.01500* 1500 7740 120 1947 490 190 4460 75.01800* 1750 2016 133 2180 260 190 5530 90.0

(mm) (ID mm) (OD mm) (T mm) (mm) (mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 215 295 40 378 150 100 123 16.9

300 292 368 38 464 222 114 277 22.5

375 369 445 38 540 235 127 356 28.1

450 445 533 44 641 257 127 500 33.8

525 514 616 51 730 263 131 659 39.4

600 585 699 57 826 295 138 837 45.0

675 673 787 57 920 318 139 878 50.6

750 738 870 66 1016 329 139 1041 56.3

825 812 946 67 1086 329 139 1343 61.9

900 869 1041 86 1194 363 139 1837 67.5

1050 1004 1194 95 1352 391 162 2326 78.8

1200 1157 1365 104 1543 424 168 2929 90.0

1350 1292 1524 116 1708 442 175 3400 101.3

1500 1461 1689 114 1886 486 190 3775 112.51500* 1500 7740 120 1947 490 190 4460 112.51800* 1750 2016 133 2180 260 190 5530 135.0

(mm) (ID mm) (OD mm) (T mm) (mm) (mm) (S mm) (Kg/Unit) (kN/m)

Page 12: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

10

S & S Class 100D - SABS 677 Type SC or SI

* Vertical cast

Nominal length 2,5mPipes available in half lengths by arrangement.Details of larger diameter pipes available on request.Dimensions and thus the mass of the pipes are subject to change without notice.For details of pipes from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE PIPES – SPIGOT AND SOCkET JOINT PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 215 295 40 378 150 100 123 22.5

300 292 368 38 464 222 114 277 30.0

375 369 445 38 540 235 127 356 37.5

450 445 533 44 641 257 127 533 45.0

525 514 616 51 730 263 131 659 52.5

600 585 699 57 826 295 138 837 60.0

675 665 787 61 920 318 139 1017 67.5

750 722 870 74 1016 329 139 1338 75.0

825 780 946 83 1086 329 139 1593 82.5

900 869 1041 86 1194 363 139 1837 90.0

1050 986 1194 104 1352 391 162 2502 105.0

1200 1127 1365 119 1543 424 168 3266 120.0

1350 1262 1524 131 1708 442 175 3800 135.0

1500 1419 1689 135 1886 486 190 4372 150.01800* 1750 2050 150 2180 260 190 5780 180.0

(mm) (ID mm) (OD mm) (T mm) (mm) (mm) (S mm) (Kg/Unit) (kN/m)

Page 13: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

11

S & S Class 50D WSL - SABS 677 Type SI

S & S Class 75D WSL - SABS 677 Type SI

S & S Class 75D - SABS 677 Type SC or SI

PRECAST CONCRETE PIPES – SEWER PIPE WITH SACRIFICIAL LAYER

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 203 295 46 375 150 100 179 11.3

300 272 368 48 464 222 114 351 15.0

375 349 445 48 540 235 127 451 18.8

450 435 533 49 641 257 127 617 22.5

525 491 616 63 730 263 131 791 26.3

600 573 699 63 826 295 138 908 30.0

675 665 787 61 920 318 139 1060 33.8

750 742 870 64 1016 329 139 1243 37.5

825 808 946 69 1086 329 139 1509 41.3

900 901 1041 70 1194 363 139 1691 45.0

1050 1034 1194 80 1352 391 162 2428 52.5

1200 1167 1365 99 1543 424 168 3019 60.0

1350 1300 1524 112 1708 442 175 3417 67.5

1500 1460 1689 115 1886 486 190 3865 75.0

(mm) (ID mm) (OD mm) (T mm) (A mm) (B mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 203 295 46 375 150 100 179 16.9

300 272 368 48 464 222 114 351 22.5

375 349 445 48 540 235 127 451 28.1

450 435 533 49 641 257 127 617 33.8

525 491 616 63 730 263 131 791 39.4

600 573 699 63 826 295 138 990 45.0

675 655 787 66 920 318 139 1053 50.6

750 722 870 74 1016 329 139 1233 56.3

825 800 946 73 1086 329 139 1555 61.9

900 870 1041 86 1194 363 139 2068 67.5

1050 1004 1194 95 1352 391 162 2717 78.8

1200 1146 1365 110 1543 424 168 3374 90.0

1350 1260 1524 132 1708 442 175 3888 101.3

1500 1432 1689 129 1886 486 190 4329 112.5

(mm) (ID mm) (OD mm) (T mm) (A mm) (B mm) (S mm) (Kg/Unit) (kN/m)

Page 14: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

12

S & S Class 100D WSL - SABS 677 Type SI

* Vertical cast

Nominal length 2,5mPipes available in half lengths by arrangement.Details of larger diameter pipes available on request.Dimensions and thus the mass of the pipes are subject to change without notice.For details of pipes from any particular factory, please contact our sales office.All dimensions in mm.

HDPE Anchor Knob Liner (optional extra)

PRECAST CONCRETE PIPES – SEWER PIPES WITH SACRIFICIAL LAYER

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socketdiameter

Socketlength

Socket depth

Mass Proof load

225 203 295 46 375 150 100 179 22.5

300 272 368 48 464 222 114 351 30.0

375 349 445 48 540 235 127 451 37.5

450 435 533 49 641 257 127 650 45.0

525 491 616 63 730 263 131 791 52.5

600 573 699 63 826 295 138 990 60.0

675 645 787 71 920 318 139 1189 67.5

750 712 870 79 1016 329 139 1527 75.0

825 770 946 88 1086 329 139 1798 82.5

900 860 1041 91 1194 363 139 2065 90.0

1050 986 1194 104 1352 391 162 2886 105.0

1200 1127 1365 119 1543 424 168 3704 120.0

1350 1230 1524 147 1708 442 175 4277 135.0

1500 1390 1689 150 1886 486 190 4910 150.0

(mm) (ID mm) (OD mm) (T mm) (A mm) (B mm) (S mm) (Kg/Unit) (kN/m)

Page 15: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

13

IWJ Class 50D - SABS 677 Type SC

IWJ Class 75D - SABS 677 Type SC

IWJ Class 100D - SABS 677 Type SC

* Also available in 150DNominal length 2,5m.Pipes available in half lengths by arrangement.Details of larger diameter pipes available on request.SI on request.Dimensions and thus the mass of the pipes are subject to change without notice.For details of pipes from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE PIPES – IN-THE-WALL JOINT PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

900 900 1100 100 100 1963 45.0

1050 1050 1250 100 100 2300 52.5

1200 1190 1390 100 100 2550 60.0

1500 1500 1720 110 100 3500 75.0

1800 1810 2130 160 150 6375 90.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

900 900 1100 100 100 1963 67.5

1050 1050 1250 100 100 2275 78.8

1200 1150 1390 120 100 3000 90.0

1500 1460 1720 130 100 4075 112.5

1800 1760 2130 185 150 7075 135.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Socket depth

Mass Proof load

900 900 1100 100 100 1963 90.0

1050 1050 1250 100 100 2275 105.0

1200 1150 1390 120 100 3000 120.0

1500 1460 1720 130 100 4075 150.0

1800 1760 2130 185 150 7075 180.0

2500* 2350 2950 300 175 16250 250.0

(mm) (ID mm) (OD mm) (T mm) (S mm) (Kg/Unit) (kN/m)

Page 16: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

14

Introduction

Concrete pipe jacking is a method of installing pipelines without disrupting existing surface facilities or activities. With the increasing growth in South African cities and towns and the consequent need to refurbish, renew and upgrade existing services, pipe jacking is seen to be a growing industry. Although the basic methods of concrete pipe jacking are similar for all pipeline applications, South African contrac-tors have developed their own individual techniques to achieve accuracy during jacking, to lengthen the jacking distance and to control varying ground conditions.

Installation method

Concrete pipes are jacked from a jacking pit to a receiver pit usually located at a manhole or access chamber. The main jacks are installed in the jacking pit and are used to push the concrete pipes into the cavity excavated ahead of the progressing pipeline. The main jack capacity depends on the size of pipe, length of the line and the type of ground in which it is being jacked. There are typically two or four jacks with capacity of up to 300 tonnes.

The jacking forces are resisted by the thrust block in the jacking pit and applied to the pipeline end through the steel thrust ring. The concrete pipe end is protected against spalling by soft wood or woodchip joint packers between the thrust ring and the concrete surface. The steel cutting shield fitted to the lead pipe gives protection to workers and allows steering and alignment adjustments. Intermediate jacking stations may be required in long lengths and hard ground conditions. Alternatively bentonite injections may be used to reduce the friction between the pipes and the soil.

Pipeline alignment is continually monitored and adjusted during jacking by laser from the jacking pit to a target fixed to the inside crown of the lead pipe or shield. Gradual adjustments are continuously made to avoid over-stressing the concrete pipe joints.

PRECAST CONCRETE PIPES – IN-THE-WALL JOINT JACkING PIPES

Page 17: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

15

Jacking Class 100D - SABS 677 Type SC

Nominal length 2,5m.Pipes available in half lengths by arrangement.Details of larger diameter pipes available on request.SI on request.Dimensions and thus the mass of the pipes are subject to change without notice.For details of pipes from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE PIPES – IN-THE-WALL JOINT JACkING PIPES

NominalDiameter

Inside diameter

Outside diameter

Wallthickness

Standardlead

Length Mass

840 Butt 810 1034 112 50 x 10 2260 1878

900 880 1100 110 200 x 20 2500 2190

1050 1030 1250 110 200 x 20 2500 2523

1117 1117 1375 129 424 x 20 2260 2922

1200 1150 1390 120 200 x 20 2500 3065

1350 1350 1600 125 200 x 20 2500 3708

1473 1473 1780 154 560 x 20 2260 4540

1500 1460 1720 130 200 x 20 2500 4158

1800 1760 2120 180 200 x 20 2500 or 2300 7025

1880 1880 2236 178 756 x 20 2000 5760

2000 Butt 2032 2432 200 80 x 12 2000 7000

2100 2100 2500 200 200 x 20 2000 7400

2350 2350 2950 300 200 x 20 2000 12795

2400 2400 2800 200 80 x 12 1000 4180

2500 2500 3000 250 200 x 20 1500 or 2440 13493

(mm) (ID mm) (OD mm) (T mm) (mm x mm) (mm) (Kg/unit)

Page 18: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

16

Introduction

Infraset design and manufacture high quality, high performance factory engineered precast concrete culverts for use in a wide range of modern construction and civil engineering projects.

The company expertise combined with modern manufacturing facilities and years of experience enables Infraset to offer an extensive range of standard culverts as well as the manufacturing of non standard, project specific culverts.

In addition to their exceptional load bearing capabilities and structural stability, precast concrete culverts require very little or no maintenance at all to exceed the useful life.

CLASSIFICATION OF CULVERTS

Types of culverts

Infraset offers the full range of S-Class rectangular portal culverts readily available in lengths of 1.2m. Culverts ranging in size from 450mm x 450mm up to 3600mm x 3000mm with Butt-joints are manufactured to the relevant S-Class strength requirements. All S-Class portal culverts bear the SANS mark and are designed, manufactured and tested in accordance with SANS 986:2006: Precast reinforced concrete culverts. Reinforced concrete bases are available for all S-Class culverts and are easily installed on site to complete a structurally stable engineered unit.

SAR rectangular portal culverts manufactured to Spoornet loading, NR 1983, have thicker deck and leg sections to accommodate larger fill heights and imposed loads. Culverts ranging in sizes from 900mm x 450mm up to 3000mm x 3000mm are manufactured and unit lengths ranging from 1.2m up to 1.5m as stated in the product tables. SAR culverts are available in 2 strength classes, 0-5m fill and 5-10m fill. Reinforced concrete bases are available for SAR culverts being placed where the fill height does not exceed a maximum of 5m.

Ribbed skew haunch culverts are designed and manufactured to withstand C-Class loading conditions, consisting of a vertical proof load of 150kN/m and a horizontal proof load of 30kN/m. Ribbed culverts range in size from 600mm x 450mm up to 3000mm x 3000mm and vary in unit length as shown in the product tables.

Infraset also manufacture jacking box culverts in various sizes and in standard lengths of 1.190m which are manufactured with bolt holes for longitudinal ties.

Strength of culverts

Precast portal culverts are classified in terms of their crushing strength when subjected to a combination of loading cases involving vertical and horizontal knife edge tests conducted under factory conditions. The proof load test can be defined as a line load that a culvert must resist without the development of crack widths exceeding 0.25mm over a length of 300mm or over two adjacent ribs in ribbed 16 culverts. When required, ultimate load test are also carried out to a magnitude of 25% greater than the applicable proof loads.

There are three different loading configurations that are applied to precast portal culverts to simulate the installed conditions, namely the deck bending moment, deck shear and the inner leg bending moment. The inner leg bending moment is only taken into consideration for the S-Class portal culverts.

PRECAST CONCRETE CULVERTS – TECHNICAL DATA

Page 19: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

17

Loads on culverts

S-Class portal culverts are tested to a vertical proof load which is a function of the strength class multiplied by the span of the culvert, a horizontal proof load of 30kN/m applied to the top of the leg and a horizontal leg load applied at a height 0.2 times the height of the leg measured from the bottom of the leg for culverts with a height to span ration of more that 0.5. The horizontal leg load is determined by the vertical load multiplied by the relevant factor.

Load classifications

Example: A 1200 x 1200 150S Culvert must resist

Vertical Proof load = 150x1.200 =180 kN/m Ultimate load = 180 x 1.25 = 225 kN/mHorizontal Proof load = 30 kN/m Ultimate load = 30 x 1.25 = 38 kN/mLeg load (Span = Height) Proof load = 180 x 0.4 = 72 kN/m Ultimate load = 72 x 1.25 = 90 kN/m

SAR portal culverts are manufactured for installations under railway track and designed to take account of train track, ballast and backfill load combinations as stated in the Spoornet Loading code of practice: NR 1983.

The fill height above the culvert, determines the strength class of the culverts. All SAR culverts are available in two strength classes to suit either 0-5m or 5-10m fill height conditions.

PRECAST CONCRETE CULVERTS – TECHNICAL DATA

450 200 200 x 0.450 30 0.2 0.45

600 200 200 x 0.600 30 0.2 0.45

750 175 175 x 0.750 30 0.2 0.4

900 175 175 x 0.900 30 0.2 0.4

1200 150 150 x 1.200 30 0.2 0.4

1500 100 100 x 1.500 30 0.3 0.5

1800 75 75 x 1.800 30 0.4 0.6

2100 75 75 x 2.100 30 0.4 0.6

2400 75 75 x 2.400 30 0.4 0.6

3000 75 75 x 3.000 30 0.4 0.6

3600 75 75 x 3.600 30 0.4 0.6

Culvert Span

CulvertClass

Vertical Proof Load

(kN/m)

HorizontalProof Load

(kN/m)

Horizontal LegLoad Factor

Span > Height

Horizontal LegLoad Factor

Span = Height

Page 20: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

18

PRECAST CONCRETE CULVERTS – TECHNICAL DATA

Installation conditions

The trench condition occurs when the culvert is placed into a trench cut into natural ground and then backfilled with suitable material.

Trenched installation

In the embankment condition the culvert is installed at ground level and is backfilled with suitable material.

Embankment installation

Culvert in precast base configuration

Temporary prop arrangement

Note: For H>1.5m, provide horizontal propsat 40% height above base during backfillingand compaction. One prop per precastconcrete unit.

Page 21: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

19

PRECAST CONCRETE CULVERTS – MAXIMUM FILL HEIGHTS ON CULVERTS

175 S 175 S

Culvert Size Foundation conditions

Span Height 1 and 2 3 and 4

750 300 8.7 4.9

750 450 9.2 5.2

750 600 10 5.5

750 750 10.5 5.8

(mm) (mm) Class Fill (m) Class Fill (m)

600 300 10.2 5.6

600 450 200 S 11 200 S 6

600 600 12 6.4

900 300 8.6 4.8

900 450 9 5.1

900 600 175 S 9.5 175 S 5.3

900 750 10 5.6

900 950 10.2 5.8

1200 300 7.1 4.1

1200 450 7.4 4.3

1200 600 150 S 7.7 150 S 4.4

1200 900 8.2 4.7

1200 1200 8.8 5

1500 300 4.5 2.9

1500 450 4.7 3

1500 600 4.9 3.1

1500 900 5.3 3.3

1500 1200 5.6 3.5

1500 1500 6 3.7

100 S 100 S

1800 600 3.3 2.4

1800 900 3.6 2.5

1800 1200 3.8 2.7

1800 1500 4 2.8

1800 1800 4.3 2.9

75 S 75 S

2100 600 3.3 2.4

2100 900 3.5 2.6

2100 1200 3.7 2.7

2100 1500 75 S 3.9 75 S 2.8

2100 1800 4.1 2.9

2100 2100 4.3 3

2400 600 3.2 2.4

2400 900 3.4 2.5

2400 1200 75 S 3.5 75 S 2.1

2400 1500 3.7 2.9

2400 1800 3.8 2.8

2400 2400 4 3

Culvert Size Foundation conditions

Span Height 1 and 2 3 and 4

(mm) (mm) Class Fill (m) Class Fill (m)

2100 900 3.5 2.6

3000 600 3.1 2.4

3000 900 3.2 2.5

3000 1200 3.3 2.6

3000 1500 75 S 3.4 75 S 2.7

3000 1800 3.5 2.7

3000 2400 3.7 2.9

3000 3000 3.1 2.7

3600 600 3.1 2.4

3600 900 3.1 2.5

3600 1200 3.2 2.6

3600 1500 75 S 3.3 75 S 2.6

3600 1800 3.3 2.7

3600 2400 3.5 2.8

3600 3000 3.5 2.7

For higher fill heights, products can be specially designed.

Page 22: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

20

Definitions

Yielding foundation conditions occur when the founding material and the fill material are expected to settle at equal rates (compressible material). The loading is calculated in accordance with TMH7 Part 2 clause 2.3.3.2 (2).

Unyielding foundation conditions occur when the founding material is incompressible (soft rock or harder material). The loading is calculated in accordance with TMH7 Part 2 clause 2.3.3.2 (3) and (4).

Trench condition occurs when culverts are laid in a narrow excavation and backfilled to ground level.

Embankment (untrenched) condition occurs when culverts are laid at ground level and backfilled to final formation level.

The combinations of foundation and installation conditions used in TMH7 are defined as:

Condition 1: Culverts in trench on unyielding foundation with no projection

Condition 2: Culverts in an embankment on yielding foundation

Condition 3: Culverts in an embankment on yielding foundation for h>1, 7b

Condition 4: Culverts in an embankment on unyielding foundation for h<1, 7b

Where h = fill heights in metres b = overall trench width or, if in an embankment, overall culvert width, in metres.

Assumptions

The following assumptions and clauses of TMH7 Parts 1 and 2 were used to compile the table above:

• A minimum fill height of 300mm over the culvert units. Where this cannot be achieved, a 100mm reinforced concrete slab must be used• Standard traffic loading SNABC• Fill material unit weight 20kN/m³ • Concrete unit weight 24kN/m³ • Horizontal earth pressure 7,8kN/m² per metre depth• Ultimate Limit State Load factors.

PRECAST CONCRETE CULVERTS – MAXIMUM FILL HEIGHTS

Page 23: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

21

SAR-Class rectangular portal culverts - NR 1983

PRECAST CONCRETE CULVERTS – RECTANGULAR PORTAL CULVERTS

S X H(mm x mm)

T(mm)

R(mm)

A(mm)

C(mm)

D(mm) (mm)

0-5m Fill(kg/unit)

0-10m Fill(kg/unit)

900 x 450900 x 600900 x 900

150 120 1200 150 138132120

1200/1500 98411081334

99111141345

1200 x 6001200 x 900

1200 x 1200

175 160 1550 175 158147135

1200 150117802076

151517932085

1500 x 9001500 x 12001500 x 1500

210 200 1900 200 170158145

1200 232926362906

234926552940

1800 x 9001800 x 12001800 x 15001800 x 1800

225 240 2250 225 195182169155

1500 3577401044174792

3626406444744857

2000 x 10002000 x 12002000 x 15002000 x 2000

225 280 2450 225 194185172150

1200 3137336636944193

3183340837414252

2100 x 9002100 x 12002100 x 15002100 x 18002100 x 2100

250 280 2550 225 199187175162150

1200 32313686402243374636

32843751408644044713

2400 x 12002400 x 15002400 x 18002400 x 2400

275 320 2850 225 189177165140

1200 4151449048205386

4205453848605471

2500 x 10002500 x 15002500 x 20002500 x 2500

275 350 3000 225 223203182162

1200 4084470652495768

4151475953165857

3000 x 10003000 x 15003000 x 20003000 x 25003000 x 3000

300 400 3580 290 266246226205185

1200 53176131681574758116

54046222690475868260

Culvert size

Dimensions Length Mass

Page 24: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

22

S-Class rectangular portal culverts - SANS 986 : 2006

PRECAST CONCRETE CULVERTS – RECTANGULAR PORTAL CULVERTS

S X H(mm x mm)

S T(mm)

R(mm)

A(mm)

C(mm)

D(mm) (mm) (kg/unit)

450 x 300450 x 450

200S200S

90 40 600 75 6560

1200 322394

600 x 300600 x 450600 x 600

200S200S200S

100 80 810 105 958780

1200/1500 453540619

750 x 300750 x 450750 x 600750 x 750

175S175S175S175S

100 100 970 110 101948780

1200 652767719822

900 x 300900 x 450900 x 600900 x 750900 x 900

175S175S175S175S175S

110 120 1140 120 1131081029690

1200/1500 640746842911

1027

1200 x 4501200 x 6001200 x 900

1200 x 1200

150S150S150S150S

120 160 1460 130 11911310290

1200 947106412731500

1500 x 6001500 x 900

1500 x 12001500 x 1500

100S100S100S100S

135 200 1790 145 12811510390

1200 1332154117791970

1800 x 6001800 x 900

1800 x 12001800 x 15001800 x 1800

75S75S75S75S75S

150 240 2130 165 14813512210995

1200 16671935218524082605

2000 x 9002000 x 12002000 x 15002000 x 18002000 x 2000

75S75S75S75S75S

160 280 2340 170 14813512210995

1200 21882455269329113029

2100 x 6002100 x 900

2100 x 12002100 x 15002100 x 18002100 x 2100

75S75S75S75S75S75S

160 280 2440 170 15614413212010795

1200 194822312495273929643169

2400 x 6002400 x 900

2400 x 12002400 x 15002400 x 18002400 x 2400

75S75S75S75S75S75S

200 320 2800 200 188176164152140115

1200 264329523267357038454343

3000 x 12003000 x 15003000 x 18003000 x 24003000 x 3000

75S75S75S75S75S

230 400 3460 230 199188176153130

1200 43244686502556656223

3600 x 9003600 x 12003600 x 15003600 x 18003600 x 24003600 x 3000

75S75S75S75S75S75S

300 400 4100 250 231219208196173150

1200 538658016213658172767903

4000 x 9004000 x 12004000 x 15004000 x 18004000 x 2400

755755755755755

320 400 4540 270 246232218204175

1200 61306572698773768072

Culvert size

StrengthClass

Dimensions Length Mass

Page 25: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

23

C-Class ribbed skew haunch culverts

PRECAST CONCRETE CULVERTS – RIBBED SkEW HAUNCH CULVERTS

S X H(mm x mm)

A(mm)

B(mm)

C(mm)

D(mm)

T(mm)

M(mm)

N(mm)

R(mm)

U(mm)

V(mm) (mm) (kg/unit)

600 x 450600 x 600

832852

630650

100 101 95 225 225375

80 101 597 1500 502578

750 x 450 1004 790 105 107 100 225 225 100 127 707 1500 577

900 x 450900 x 600900 x 900

117211521168

946930946

110 113111

100 225300450

225300450

120 150142134

821835852

1500 643724914

1200 x 4501200 x 6001200 x 900

1200 x 1200

1452149215081522

1246123012461260

100130

103131

120 225300450600

225300450600

160 210195183176

980107110941108

1200 624808983

1158

1500 x 6001500 x 900

1500 x 12001500 x 1500

1798182818421856

1516154615601574

140 141 130 450450600750

150450600750

200 230230221215

1320132013371348

1200 987115513361521

1800 x 6001800 x 900

1800 x 12001800 x 15001800 x 1800

21182148216221762192

18161846186018741890

150 151 140 450450600750900

150450600750900

240 277277267260255

15451545156515791589

1500 14921736199222532520

2000 x 9002000 x 12002000 x 15002000 x 2000

2266229623262376

2030206020902140

125 118 155 600600600600

300600900

1400

275 294294294294

1642164216421642

1200 1429158817532030

2400 x 9002400 x 12002400 x 15002400 x 18002400 x 21002400 x 2400

270627262756274227602786

245024702500248625042530

140 128 170 500500500900900900

400700

1000900

12001500

320 364364364334334334

192319231923198219821982

1200 174019102081230024742649

2500 x 15002500 x 18002500 x 20002500 x 2500

2826285128662961

2570259526102660

140 128 170 900900900900

600900

11001600

325 391391391391

1968196819681968

1200 2142231424342733

3000 x 9003000 x 12003000 x 15003000 x 18003000 x 21003000 x 24003000 x 3000

3318333833683368338834183478

3050307031003100312031503210

150 134 180 500500500900900900900

400700

1000900

120015002100

400 482482482446446446446

2296229622962368236823682368

1200 2113229824852700288830633429

Culvert size

Dimensions Length Mass

Page 26: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

24

Leg section dimensions

Dimensions and thus the mass of the culverts are subject to change without notice.For details of culverts from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE CULVERTS – RIBBED SkEW HAUNCH CULVERTS

600 101 61 40 162 65 20 90

750 107 67 40 162 65 20 90

900 x 450 113 73 40 162 65 20 90

900 111 71 40 162 65 20 90

1200 x 450 103 73 30 162 61 20 90

1200 131 81 50 162 61 20 90

1500 141 91 50 162 61 20 90

1800 151 86 65 162 65 20 90

2000 118 63 55 173 80 10 90

2400 128 68 60 173 80 10 90

2500 128 68 60 173 80 10 90

3000 134 74 60 173 80 10 90

Culvert span

D(mm)

p(mm)

a1(mm)

W(mm)

X(mm)

Y(mm)

Z(mm)

Page 27: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

25

PRECAST CONCRETE CULVERTS – CULVERT BASES

Culvert bases

Dimensions and thus the mass of the bases are subject to change without notice.For details of culverts from any particular factory, please contact our sales office.All dimensions in mm.

(mm x mm)A

(mm)B

(mm)C

(mm)D

(mm)E

(mm) (mm) (kg/unit)

450 S 650 440 105 90 20 1200 207

600 S 860 580 140 90 20 1200 273

750 S 1020 725 148 95 20 1200 342

900 S/SAR 1250 875 188 120 20 1200 515

1200 S/SAR 1600 1180 210 140 20 1200 761

1500 S/SAR 1950 1475 238 160 25 1200 1072

1800 S/SAR 2300 1775 263 180 25 1200 1408

2000 S/SAR 2500 1990 255 200 25 1200 1689

2100 S 2490 1990 250 160 25 1200 1377

2400 S/SAR 2900 2380 260 210 25 1200 2054

2500 S 2950 2380 285 170 25 1200 1723

SAR 3050 2380 335 270 25 1250 2826

3000 S 3510 3005 253 190 25 1200 2280

SAR 3630 3005 313 310 25 1250 3841

3600 S 4150 3595 278 200 25 1200 2826

Span Class Dimensions Length Mass

Page 28: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

26

Jacking box culverts

Dimensions and thus the mass of the culverts are subject to change without notice.For details of culverts from any particular factory, please contact our sales office.All dimensions in mm.

PRECAST CONCRETE CULVERTS – JACkING BOX CULVERTS

S(mm)

H(mm)

T(mm) (mm) (kg/unit)

3000 2500 275 1190 10400

3000 3000 275 1190 11300

Culvert Size Wall Thickness Length Mass

Page 29: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

27

PRECAST CONCRETE MANHOLES – 6-WAY CONCRETE BASE

Features

• The Ø 1000mm precast base provides the foundation, channelling, benching and starter ring in one complete unit• Inlet knockouts are available for fitment from 0°, 45° and 90° into the Ø 150mm channels • Complete with a 100mm thick precast base, this 500mm high unit makes the construction of a manhole easy.• (Starter rings with precast bases on larger diameter manholes can be cored according to client specifications).

Page 30: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

28

PRECAST CONCRETE mANhOlES – COmPONENTS

Cover Slabs

To fit(mm)

Hole D (mm)

ThicknessT (mm)

Mass(kg/unit)

1000 560 150 279

1250 560 185 581

1500 560 220 1072

1750 560 220 1495

Ekgangala Slabs

To fit(mm)

Hole D (mm)

ThicknessT (mm)

Mass(kg/unit)

750 560 100 69

1000 560 150 269

1250 560 185 571

1500 560 220 1065

1750 560 220 1487

Shaft Section

Internal Diameter(mm)

Wall Thickness(mm)

Mass(kg/500mm unit)

750 55 169

1000 560 150

1250 560 185

1500 560 220

1750 560 220

Chamber Sections

Internal Diameter(mm)

Wall Thickness(mm)

Mass (kg/500mm unit)

1000 65 276

1250 75 394

1500 85 535

1750 95 696

1750 560 220

All chamber and shaft sections available in 250, 500 and 1000mm lengths.

Dimensions and thus the mass of the manholes are subject to change without notice. For details of manholes from any particular factory, please contact our sales office. All dimensions in mm.

Page 31: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

29

PRECAST CONCRETE MANHOLES – COMPONENTS

Spacers

Description ThicknessT (mm)

Mass(kg/unit)

Round 750 with 560 hole 75 64

Lids

- Heavy and medium duty replacement lids for cast iron frame

- Extra heavy, heavy and medium duty lids for concrete frame

- All lids made with a fitted steel band

Frames

- All lids fit in concrete frame

- Extra heavy duty frames made with a steel seatband

Adaptor Slabs

Description ThicknessT (mm)

Mass(kg/unit)

Square 750 with 560 hole 127 184

Round 750 with 560 hole 110 90

Reducer Slabs

To fit(mm)

Reduce to D(mm)

ThicknessT (mm)

Mass(kg/unit)

1000 750 150 205

1250 750 185 492

1500 750 220 968

1750 750 220 1393

Page 32: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

30

PRECAST CONCRETE MANHOLES – TYPE 2A & 2C CONCRETE LIDS

Features

• Type 2A and 2C reinforced concrete lids are manufactured using high strength 40MPa concrete• The lids are cast with a 2mm thick galvanized steel band around the perimeter and are finished with a non slip “check plate” imprint on the top.• CAPE REGION ONLY

Type 2A Lid

Type 2C Lid

Page 33: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

31

PRECAST CONCRETE MANHOLES – MANHOLE CONFIGURATIONS

OPTION 1NB – Cast iron frames 2 & 2A require square adaptors and spacers while cast iron frames 4 & 4A require round adaptors and spacers.

Heavy duty lids tests to 120kN.

Medium duty lids tests to 60kN.

Both heavy and medium duty lids fit in the frame which is 130mm high.

A round spacer can be used. This is 75mm high. A square spacer is 100mm high.

Access shaft sections are 750mm in diameter and available in heights of 250, 500 and 1 000mm.

The reducer slab reduces chamber sections to 750mm shaft sections and is available in four sizes (1 000, 1 250, 1 500 and 1 750) and heights respectively (150, 185, 220 and 220mm) and has a 750mm diameter hole. Option 2 allows for a cover slab instead on which a frame and lid can be fitted.

Throughout all options three types of bases can be used. Precast complete with benching, a cast-in-situ founda-tion using a 250mm chamber section or a 500mm section conversion.

OPTION 2Option 2 does away with the adaptor and shaft section/s and instead of a reducer slab, a cover slab is used.

NB – Cast iron frames 2 & 2A require square spacers.

NB – Cast iron frames 4 & 4A require round spacers.

Heavy duty lid tests to 120kN. Medium duty lid tests to 60kN.

Both heavy and medium duty lid fit in the frame which is 130mm high.

A round spacer can be used. This is 75mm high. A square spacer is 100mm high.

The cover slab is available in four sizes (1 000, 1 250, 1 500 and 1 750) and heights (150, 185, 220 and 220mm) respectively and has a 560mm hole.

Throughout all options, three types of bases can be used. Precast complete with benching, a cast-in-situ founda-tion using a 250mm chamber section or a 500mm section conversion as shown here.

Please note that the drilled holes should not be closer than 150mm from either the top or bottom of the section.Example dimensions are shown.

OPTION 3Option 3 does away with the frame, spacer, adaptor and access shaft used in Option 2, with the lid fitting directly into the Ekgangala slab.

Heavy duty lid tests to 120kN.

Medium duty lid tests to 60kN.

The Ekgangala slab accommodates the lid directly. It is available in five sizes (750, 1 000, 1 250, 1 500 and 1 750mm) and heights (100, 150, 185, 220 and 220mm) respectively.

A 250mm chamber section is used to construct a cast-in-situ foundation.

Throughout all options, three types of bases can be used.

Precast complete with benching, a cast-in-situ foundation using a 250mm chamber section or a 500mm section conversion.

Page 34: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

32

kERB INLET (CATCHPIT)

Features

• Sidewalk mounted catch pits are available in two depth sizes : 400mm and 700mm• The top slab of the catch pit, which has a non slip surface, allows for easy access for cleaning purposes• The front of the unit can be fitted with either a barrier or a roll-over piece depending on the installation• Catch pits are designed to be used in conjunction with an inlet kerb, the profile of which matches any standard kerb• Supply of matching inlet channels may be arranged for use in kerb and channel situations• These precast units have an inflow area of 0.142m².

Page 35: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

33

kERB INLET (CATCHPIT)

Page 36: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

34

ASSOCIATED PRECAST CONCRETE PRODUCTS CHANNELS AND DRAINS

Channels and Drains

The Infraset channels and drains are tailor made for the most common water channeling problems in the civil

engineering and mining industry. Products vary from a light weight fiber-reinforced Flolok channel to the heavy duty

300mm channel and lid.

A(mm)

B(mm)

T(mm)

H(mm)

C(mm)

370 290 40 185

540 450 45 270

625 525 50 313

336 300 18 170

436 400 18 220

367 300 34 230 200

467 400 34 230 200

610 510 50 250 450

440 320 60 350

110

Product Type

300 Half Round Channel

450 Half Round Channel

525 Half Round Channel

300 Flolok Channel

400 Flolok Channel

300 Dura Drain

400 Dura Drain

Interlocking Drain

300 Channel

Lid

Length(mm)

Mass(kg/unit)

1250 62

1250 120

1200 145

1500 15

1500 18

1500 78

1500 85

1000 130

1000 180

1000 119

Dimensions

Page 37: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

35

ASSOCIATED PRECAST CONCRETE PRODUCTS AIR VALVE CHAMBER AND ORE PASS LINER

Air valve chambers

The air valve chamber is a sectionalized structure designed and developed to provide the industry with a high quality, accurate and long lasting method of erecting chambers. Incorporating specially designed step irons, the chambers are easy to install, can be made watertight and can be erected in hours rather than days.

All units are fitted with lifting sockets to facilitate safe, easy and effective handling. All units are manufactured with interlocking joints.

Section Dimensions Length(m)

Mass(kg/unit)

Thickness(mm)

Small Chamber 2000 x 2000 500 1650 *150

Small Roof 2300 x 2300 1850 **150

Large Chamber 2500 x 3000 500 2230 *150

Large Roof 2800 x 3300 2660 **150

* Wall thickness** Roof thickness

Page 38: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

36

Median Barriers

The Infraset median barriers are robust, double sided, high quality precast units that can be used not only to delineate traffic

but also as sectional dividers in stock yards. Made from high strength 40 MPa concrete, at a length of 2 meters and weighing

just over 1800 kg, these units can be installed with confidence as an effective containment solution. The units are manufactured

with an interlocking joint system that eliminates the need for fish plates and the open channels at the bottom makes for easy

handling with a forklift.

ASSOCIATED PRECAST CONCRETE PRODUCTS MEDIAN BARRIERS

Page 39: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

37

ASSOCIATED PRECAST CONCRETE PRODUCTS SUMP/PUMP STATIONS CHAMBER

Sump/pump station chambers

Standard rings which come with lifting points for ease of handling.

Custom-made rings with inlet/outlet ports and dolomitic aggregates can be made on request.

Base rings and top slabs are also available on request.

* Availability dependant on mould location

Dimensions and thus the mass of the products are subject to change without notice.For details of special precast products from any particular factory, please contact our sales office.All dimensions in mm.

Mass(kg/unit)

3550

4000

5150

Dimensions

Product Type (mm)(mm)

2100

2400

*3650

OD(mm)

ID(mm)

Wall(mm)

Length(mm)

2500 2100 200 1000

2800 2400 200 1000

4000 3650 175 1000

Page 40: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

38

ASSOCIATED PRECAST CONCRETE PRODUCTS TOILETS

ToiletsThese practically indestructible precast toilets are designed to accommodate waterborne, chemical or pit latrine systems, small bore or soak away septic tanks, conservancy tanks or virtually any alternative sewage system.

Ideal for waterborne systems the toilets are available with any combination of toilet pans, showers, taps and wash trough basins. Basins are transported separately and easily fitted to the structure on site.

The integral floor has been designed for effective drainage and to provide the structure with a solid base to stand on which results in little foundation preparations.

Pipework, where applicable, is fitted on the inside of the toilet wall and pressure tested.

Unit Mass: 1125kg

Page 41: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

39

Features

• The INFRASET wash trough basin is an optional extra for

the Infraset Precast Toilet

• Manufactured from 45 MPa concrete, the wash trough

weighs only 80 kilograms and has a capacity of 60 liters

• Supplied with a 40mm diameter waste hole and two

fitment holes, the wash trough is a useful addition to the

toilet structure.

ASSOCIATED PRECAST CONCRETE PRODUCTS PRECAST WASH TROUGHS

Wash Throughs

Page 42: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

40

ASSOCIATED PRECAST CONCRETE PRODUCTS BUS SHELTERS

Bus sheltersThis aesthetically pleasing structure with optional sidepanels is one of the latest additions to the infrastructureproduct range.

Purpose-made and maintenance free, these structuresprovide a safe shelter for passengers from the harshestenvironmental conditions. Lifting holes and cast-insockets facilitate safe and effective handling on site.

Unit length: 1,200mUnit Mass: 2650kg

Page 43: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

41

RAILWAY PRODUCTS

Introduction

INFRASET design and supply various types of prestressed concrete railway sleepers for main lines and sidings. These prestressed concrete sleepers sustain axle loads of 18.5 tonnes for sidings, 22.5 tonnes for mainlines and 30 tonnes for heavyhaulage lines. Listed below are some of the sleepers INFRASET supplies to the industry:• Siding sleepers for light traffic• Mainline sleepers for normal goods and passenger trains• Sleepers for heavy haul conditions• Specialised sleepers for turnouts ranging from 1:9, 1:12 and 1:20• Low profile sleepers for stations and sidings• Electrification masts and poles

LANDSCAPE PRODUCTS

Introduction

INFRASET produces various types of precast concrete landscape products for the domestic and commercial markets. Some of the products include:

Paving blocks in a variety of shapes, colours and finishes

• G-Bloks and Craz’E’ G-Blok • Cottage Stone• Village Cobble • Rossway Rock• Rumblestone • Classic Cobble• Craz’E’ Classic Cobble • Masonique• Uni-Decor • Bush Stone

Retaining wall systems for a range of applications

• Loffelstein • Waterloffel• Terrace Blok

Specialised precast products

• Precast stadium seating • Garden kerbs• Masonry products • Flocon beam and block flooring

ASSOCIATED PRECAST CONCRETE PRODUCTS PRODUCT RANGES

Page 44: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

42

FLOW CHART FOR CIRCULAR PIPES

Page 45: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

43

NOTES

Page 46: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

44

NOTES

Page 47: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

45

Page 48: Westonaria Tel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417media.autospec.com/za/infrasetinfrastructure/pdf/infrastructure.pdf · Culvert Bases Jacking Box Culverts Precast Concrete

46

For further information, please contact:

HEAD OFFICE

Steeledale House

669 – 670 Power Street, Industries West, Germiston

PO Box 751752, Garden View, 2047

Tel +27 (0)11 876-5500

Fax +27 (0)11 872-1713

Email [email protected]

www.infraset.com

SwazilandTel +268 518-4263 • Fax +268 518-5481

WestonariaTel +27 (0)11 753-2269 • Fax +27 (0)11 753-2417

INFRASTRUCTURE PRODUCTS

WadevilleTel +27 (0)11 827-3517 • Fax +27 (0)11 824-3106

KuilsrivierTel +27 (0)21 908-1156 • Fax +27 (0)21 908-1054

PietermaritzburgTel +27 (0)33 387-2236 • Fax +27 (0)33 387-4226

RAILWAY PRODUCTS

Brakpan Factory, Sales and Marketing Office

National +27 (0)11 813-2340 • Fax +27 (0)11 817-3625

De AarTel +27 (0)53 631-0827 • Fax +27 (0)53 631-0980

PAVING AND LANDSCAPING PRODUCTS

RosswayTel +27 (0)12 652-0000 • Fax +27 (0)12 652-0132

KwaZulu-NatalTel +27 (0)31 569-6900 • Fax +27 (0)31 569-6903

AUGUST 2009