what is gt master while gt pro is the design program for combined cycles, gt master is the...
TRANSCRIPT
What is GT MASTER
While GT PRO is the design program for combined cycles, GT MASTERis the corresponding simulation program for off-design calculations.
Use GT MASTER to evaluate designs at various ambient conditions and loads.
All GT MASTER hardware inputs has automatically been initialized based on thedesign, which makes it possible to perform calculations by just changing a few parameters.
Since GT MASTER hardware inputs are editable, the model may be fine tuned to matchan existing plant or vendor data.
In combination with PEACE (Plant Engineering and Construction Estimator), GT MASTERprovides engineering details and cost estimation.
WHAT IS GT MASTER?
Thermoflow Inc.
GT MASTER
Activating the GT MASTER program will display this input screen for selecting the desired file.
All GT MASTER models are based ona GT PRO design.
GT MASTER will allow the user to dooff-design calculations, such as partload and varying ambient conditions.
Load existing GT MASTER fileor import GT PRO file.
GT MASTER
GT MASTER
All the main topicsare arrangedhorizontally tounderline the factthat, contrary todesign in GT PRO,off-design in GTMaster has nonatural order ofediting the topics.
The input screens applygraphical displays to ease theuse of the program.
The user may goback to GT PRO toredesign the plantif necessary.
“Green” topicsare available forPEACE licensesonly, and theirinputs primarilyimpacts the costcalculations.
At any time during the session the user canpress compute to activate the calculation.
GT MASTER
GT MASTER
Adjust gas turbine loadfor part load calculations.
Confirm actualambient conditions.
Every entry box has been filled with a values from thedesign model. The user never has to fill an emptybox. Instead the user edits just those that are ofconcern to him.
GT MASTER
GT MASTER
Select the appropriatesteam turbine controlmethod.
Each main topic holds a set of input tabs for sub topics related to themain topic. E.g. highlighted main topic is ST Inputs. Sub-topics of theST Inputs are Steam Turbine Main Inputs, Stage Groups & Controls, etc.
Each sub-topic tab letsthe user set inputs forthat specific sub topic.
Select theappropriatedesuperheatingmethod for theHRSG control.
GT MASTER
GT MASTER
GT MASTER is based onhardware models witheditable size anddimensions. This allowsthe user to adjust valuesto match an existingplant or a vendor’s data.
Since GT MASTER applieshardware models theheat balance calculationswill reflect any change inthe hardware.
Cost of the plant will alsobe recalculated takingthe changes into account.
The user may summon the Help on bothinput and output screens. It will displaythe GT MASTER manual, and, if applyingCurrent Topic (F1) or pressing F1directly, go to the section related to thehighlighted input or output.
GT MASTER
GT MASTER
Even details of tube bundledesign such as fin-tube type,materials, tube length,bundle width, number ofrows, tube diameter and findimensions may be edited.
This flexibility allows theuser to match known plantdata.
GT MASTER
GT MASTER
Pressing Compute willactivate the calculationengine and (afterconvergence) displaythe outputs from thecalculation.
Also the steam property formulation may beselected.
Available formulations:
Thermoflow Proprietary (STQUIK)
IFC-67 (previous ASME standard from 1967)
IAPWS-IF97 (current ASME standard from 1997)
Common unit systemsfrom around the world aresupported by GT MASTER.
GT MASTER
GT MASTER
Text display of the outputs is organized in a way to give theuser both a good overview anddetailed information about theplant performance.
Plant Summary will give themain plant data, whereas thesubsequent tabs will displaymore detailed information.
At any time theuser can go backto edit the inputs.
Output is displayed in three groups: Text (text and tables of thermodynamic results and hardware), Graphics (graphicaldisplay of same), and PEACE (spec sheets, cost breakdown, economic projections).
Each topic holds a large number of tabs eachdescribing part of the plant results.
GT MASTER
GT MASTER
Multiple runs may be performed applying theThermoflow Macro for studies of parameter variations.
This table willgive the user anoverview of allHX in the HRSGby showing theHX hardwareinformation sideby side.
GT MASTER
GT MASTER
Main displaysthe main plantoutput. Detailscan be found onthe subsequenttabs.
GT MASTER
GT MASTER
Details of theplant coolingsystem.
GT MASTER
GT MASTER
Boiler drums and deaerator
Transition from gas turbine
Stack
HRSG main dimensions
Displayed is the elevation view of the HRSG.
Tube bundles
Schematics showing the main components in the plant are selected through a Schematics List. Examples are: Site Plan, Gas turbine, HRSG (as shown), Steam turbine, Condensers, Cooling towers and pumps.
GT MASTER
GT MASTER
Each tab represents a major partof the power plant. Selected fordisplay is the steam turbine.
The tables will display detailedinformation about sizes and weightof the selected element or groupof elements of the plant.
GT MASTER
GT MASTER
Each tab represents a part of the total cost ofthe power plant.
Selected for display isthe SpecializedEquipment.
The tables will displaydetailed informationabout equipment andlabor cost.
Project Cost Summarytab is displaying thetotal cost of the powerplant.
Cash Flow will tell the user how the economy throughout the lifetime of the plant will be.
Reference cost is the cost at a reference US Site, whereas Estimated cost is the cost at the actual site.
GT MASTER
GT MASTERThermoflow Macro enables the user to performseries of calculations in an easy and fast way.
Inputs to vary inthe macro may beselected from anextensive list ofinputs availablefrom GT MASTER.
Part load calculationswith constant ambientconditions.
Full load calculations with varyingsite cooling water temperature.
GT MASTER
GT MASTER
Plant Summary and the subsequent 7tables display fixed lists of output data.
For each case GT MASTER output can be displayed.
Plots can be created.As an example Plantnet eff vs. GT load.
Any of the general tabs allows the user to define which data (outputsas well as inputs) to display in thatspecific table.
All tables can be exported to Exceldirectly or saved as a .CSV file forlater load into Excel.
GT MASTER
GT MASTER
Please contact Thermoflow for further information.
THERMOFLOW, INC.
2 Willow St., STE. 100
Southborough MA 01745
USA
Tel: +1-508-303-5033
Fax: +1-508-303-5022
E-mail: [email protected]
GT MASTER