Presenter: Stephan Baumann
Agilent Technologies, Inc.; Santa Clara, CA
ASTS Talk
November, 2016
5977 SQ 7000 TQ 7200 QTOF
6560 IM QTOF
6550 QTOF6540 QTOF6420 QQQ 6470 QQQ 6490 QQQ
6120 SQ
6130 SQ
6150 SQ
8800 ICO-QQQ7700 ICP-MS
When is it Time to Move to MassHunter?
1
Our Goal is to provide you a basic introduction and understanding of the MassHunter Workflow and MSD Operating System
2
MassHunter SoftwareOne software for all Agilent Mass Specs
Minimize the learning and optimize the use of software in yourlab across different mass spec instrument platforms• Control of Agilent 6000 Series QQQ, TOF and Q-TOF• LC/MS Data Processing for QQQ, TOF, Q-TOF, SQ• Control and data processing for GC/MS including GC-QQQ, GC Single
Quad and GC-QTOF• Control & data processing for ICP/MS
LC/MS GC/MS ICP-MS
3
MassHunter – A Software SuiteMassHunter software is modular: Different modules that focus on these specific tasks:
A common reporting engine
Suite of accessory applications: Unknown Analysis: batch versions of deconvolution and library
searching Library editor Method development assistants Data Translators
Acquisition (Instrument Specific) Quantitative Analysis (Quant) Qualitative Analysis (Qual)
4
GC/MS SoftwareMassHunter Qual
MassHunter QuantMH
CS
MassHunter GC/MS Acquisition
And Use EitherMassHunter Data Analysis
ORMSD ChemStation Data AnalysisMSD ChemStation DA
G1701FA
5
GC/MS MassHunter EnviroQuantConcerns relative to ChemStation EnviroQuant
Analyze Button• The analyze button was inexplicably removed by MassHunter Quant
software team. The feature can be restored by changing setting within MassHunter.
Changing File Name• ChemStation EnviroQuant has the capacity to change sample information.
Any changes are tracked. MassHunter does not have this flexibility. However, the file name can be changed in the sample directory and this name is displayed in the Quant results.
Printing an Injection Log as opposed to a Sequence Log• ChemStation EnviroQuant provides a true Sequence Log. MassHunter
EnviroQuant can print a log of files in a directory. These are identical if all the data (blanks, calibrators, continuing calibrators, etc. are stored together.
6
GC/MS ChemStation DrugQuantDifferent than ChemStation DrugQuant
Resolution, Fronting and Tailing parameters • These tools are built into MassHunter but they are not in the report. Tune Time Stamp (Fixed in B.07.05)• MassHunter can’t read the time stamp directly. There are five report types in ChemStations• MassHunter has a several templates and custom templates can be
created. This provides us with additional flexibility.
Note that there is a good MassHunter DrugQuant workflow guide (G6845-90007) that is very helpful in setting up the software correctly. There is also the Sequence_Decisions.Log that helps with intelligent sequencing troubleshooting.
7
GC/MS Acquisition MethodsMSD Productivity ChemStation MassHunter GC/MS Acquisition
GC/MS Acquisition Methods are Transparentfrom MSD ChemStation to MassHunter GC/MS
8
MassHunter Data Analysis SoftwareMassHunter’s main data analysis modules have different functions:
Quantitative (Quant):(Target Analysis - Quantitation) Review Batch results Visualize quality outliers Powerful quantitation engine Compounds-at-a-Glance Library Editor Unknowns Analysis
Qualitative (Qual):(Discovery of non-target compounds or features, & Method Development) Finds compounds Identifies compounds Uses chromatogram and spectra
extraction tools, i.e. deconvolution Searches El Libraries
9
Migrate Data to MassHunter Format
Data
Data
Data
MassHunter Quant
MassHunter Unknowns Analysis
MassHunter Qual
ChemStation (.D)
WorkStation (.SMS)
Generic (.CDF)
10
Migrate Quantitative Methods to MassHunter Format
Method
Method
ChemStation (QDB.MTH)
WorkStation (.mth)
MassHunter Quant
11
MassHunter WorkStation Qualitative AnalysisData Navigator
Method Explorer
Chromatogram Results
Method Editor
Spectrum Results
12
Extract Chromatograms
Types of Chromatograms
TIC – Total Ion Chromatogram
BPC – Base Peak Chromatogram
EIC – Extracted Ion Chromatogram
SIM – Selected Ion Monitor
MRM – Multiple Reaction Monitor (Triple Quad)
pNLC - Precursor Neutral Loss Chromatogram (Triple Quad)
Other Chromatograms – GC, ADC, DAD, VWD
Instrument Curve - %Comp., Temps, etc.
Extract multiple signal types to create Chromatograms
Definition of signals can be stored in the method and used with automation
13
Extract Spectra
•Manual selection or based on integrated peaks
•Background subtraction based on defined regions or peak definition
14
Find Compound by Chromatogram Deconvolution
•Agilent deconvolution algorithm, similar to AMDIS, integrated into MassHunter
• Creates Compounds with chromatographic and spectral components
15
Identify Compounds with Library Search
•Library search User Spectra or Compounds.•Library search parameters are part of a method.•May use Retention Time or Retention Index in search
16
Utilize NIST library searches• Export spectra to NIST
• Requires NIST (not included in Qual)
• Information does not flow back to Qualitative MassHunter reports
17
A dedicated application, the Library Editor, is used to create, edit, and modify user libraries.
Agilent provides over 15 El Libraries such as:
NIST14Wiley11th+NIST14 Fiehn Metabolite Library Japanese Pesticide list Toxicology LibraryControlled Substances
Library Editor & Available Libraries
18
Annotate and Document Annotate chromatograms and spectra using text, graphics (.jpg) and chemical structures (.mol)
Mass Caliper to document fragmentation and losses
Export or copy & paste graphics into presentations
19
Quantitative Analysis Screen
Compound Information
Results Information
Batch Information(i.e., Calibration Curve)
Results Informationfor the batch can be displayed. Visual guides highlight specific data that fall outside specific, predefined conditions.
Batch Informationprovides easy visualization and customization of relevant desired data.
The Quant Batch screen looks like this.
Compound Information displays graphical representation of the peak, qualifier information, spectral information, and the ISTD. Visual guides help identify associated data problems.
20
Batch Screen – Sample & Results Information
These icons filter outliers in the display.
In Results Information, the Quantitation Message is a human-readable string that contains a list of error messages that result from a compound's quantitation.
Blue = low / Red = high
“Outliers” define and specify results of known problem samples/substances that fall outside predefined conditions.
21
Results Information: Outlier Options
>40 quality checks can be specified to highlight outliers in results.
Can set high and low limits.
User defined quality check can be added to predefined calculations.
22
Batch Screen - Compound Information
CompoundIntegration
QualifierInformation
SpectrumInformation
ISTDIntegration(Quantitation: Part of Agilent’s ParameterlessIntegration)
ISTD QualifierInformation
ISTD SpectrumInformation
Compound information displays all relevant information in one view.
• Uncertainty Bands• Actual Ratio• Manual Integration
23
Batch Screen - Library Reference SpectraSupports correct identification of compound• Visual comparison of Sample and Library Spectra• Seen in Batch-at-a-Glance and on Reports• Head to Tail Style, Head to Head not yet available• Extracts Spectra from Library by matching on CAS number based in Quant
method and creates a small reference library (reflibrary.xml)
24
Batch Screen – Calibration Curve
View ISTD responses or display QC samples - click either the ISD or QC button.
Change Curve Fit
R2.
Zoom in/out button (right click/drag)
Concentration can be set as relative (to ISTD) or actual.
An example of Batch Information is this view of the Calibration Curve. The Curve fit can be changed and data can be updated instantaneously.
After editing the calibration curve, you must reanalyze the batch.
25
Batch Screen - Curve Fit Assistant
Calculates all possible calibration curve combinations.
26
Compounds-at-a-Glance
View up to 10 x 10 chromatograms Overlay Target with ISTD Overlay Quantifier with Qualifiers View chromatograms across 100 samples
5 x 55 x 5 10 x 1010 x 10
Compounds-at-a-Glance allows you to view multiple traces of compounds at a single glance.
27
Compounds-at-a-Glance
Shaded automatically
You can view compound outliers at-a-glance too.
28
Compounds-at-a-GlanceYou can view the manual integration of compounds at a glance too.
29
Quantitation Method CreationEasy way to create a target method from acquired data (MRM, SIM or Scan).Using information from a data file, MassHunter Quant can create a target compound list - generating Compound Name, Retention Time, Quant and Qual ions, and ratios automatically.
30
Automatic Compound Detection – Scan DataAutomatic compound detection works with both MRM and Scan data.For scan data, Library information can be used to add compound name and CAS#; The Quant and Qual ions and ratios are taken from the data file information.
31
Overview of Unknowns AnalysisQuant addresses target compound list
What else is present in the samples?
Ion Extraction
Unknowns Analysis
Deconvolution
and
Library Search
Quantitation
32
Quant & Unknowns Analysis WorkflowMS Scan data
Chromatogram Chromatogram
Extract
Integrate
Deconvolute
Library Match
Spectra
Target Match
Integrate
Quantitation
33
Unknowns Analysis
34
Chromatogram
Chromatogram displays selected component(s) in Blue
All non-selected ions (EIC) displayed in Green
TIC displayed in BlackClicking in the Chromatogram display selects the nearest peak and selects it in Components table
35
Spectrum & Ion PeaksQuant Method
Qualifier Target Default number ions displayed in Ions Peaks is 5, limit is 10
Click on ion in Spectrum to make it add / remove in Ion Peaks
Click on label in Spectrum or Ion Peaks to remove
36
Training Resource - Familiarization Guide
Familiarization guide covers basic operations
Examples use example data on media
Familiarization Guide in English Japanese Chinese
37
Training Resource – Videos and Help
R&D Videos –• Good introduction• Lacking in details
Help
38
MassHunter Excel Reporting
• Excel Based (Excel 2010/2013 supported)
• MassHunter application exports data in XML and graphics files
• Templates define report formatting
• Over 100 shipping report templates in Excel and PDF format
• Reports can be altered for desired information & appearance
• Customization using Excel features (function, formatting, code)
• Computer Based Training for report customization by users
• Some customization available through Agilent
39
Report Template Design WorksheetsCustomize the template by placing data and graphics in the desired locations
Templates may have multiple Design worksheets with different layouts
40
Excel XML Source Window• Reporting uses XML mapping to import results into templates
• Drag and drop to add data to existing reports
41