Who’s Afraid of the Settling Flux?
M.TRUETT GARRETT, JR., Sc.D, P.E.
Click on View, Notes page, to see
references and comments.
![Page 2: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/2.jpg)
Who’s afraid of the settling
flux?
• The ATV, Abwassertechniche Vereinigung,
in Germany 1991. Currently DWA, 2007.
• WEF Publication Committee, Manual of
Plant Operation does not mention flux.
• Ekama, et al, Secondary Settling Tanks,
1997, cite “…a lack of confidence in the
predictive power of the flux theory.”
![Page 3: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/3.jpg)
Who’s afraid of the settling
flux?
• “Flux theory” may not be well understood
so that many are hesitant, afraid, to use it,
being concerned that their results may not
be correct.
![Page 4: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/4.jpg)
ACTIVATED SLUDGE SETTLING
VELOCITY VS. CONCENTRATION
0
1
2
3
4
5
6
0 1 2 3 4 5 6
SOLIDS CONCENTRATION, g/L
SE
TT
LIN
G V
EL
OC
ITY
, m
/hr
![Page 5: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/5.jpg)
ACTIVATED SLUDGE SETTLING
VELOCITY VS. FLOC VOLUME
0
1
2
3
4
5
6
0 20 40 60 80 100
FLOC VOLUME, DSV30, %
SE
TT
LIN
G V
EL
OC
ITY
, m/h
r
![Page 6: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/6.jpg)
Illustration Of Terms
Overflow
Inflow
Underflow
Inflow = Overflow + Underflow
Area of the tank
![Page 7: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/7.jpg)
Definition Of Terms
Overflow rate = V = Qo/A, m/hr
Underflow rate = U = Qu/A, m/hr
Inflow rate = (V + U) = (Qo+Qu)/A
Feed concentration = C, g/dL, percent
Underflow concentration = Cu, g/dL
Settling velocity of solids = Vs, m/hr
![Page 8: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/8.jpg)
Definition Of Terms, cont’d.
• Feed Floc Volume = FV, mL/dL, percent by volume.
• FV = DSV30 = DSVI x C
• DSVI = SVI of mixed liquor
sample diluted so that sludge volume after 30 min. < 30%.
![Page 9: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/9.jpg)
• Michaels and Bolger showed that flocculated kaolin slurries settle as flocs.
• Scott found the Richardson and Zaki relationship applicable to settling data for calcium carbonate slurries.
Vs = Vso x (1- kc)4.65
Where kc is the floc volume, k has the dimension mL/g, the same as the SVI, c is the solids concentration, g/mL.
• Vso is the Stokes settling velocity of the average floc.
![Page 10: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/10.jpg)
• Scott found that the R-Z relationship
applied for values of kc less than about
0.4.
• Since we defined C as percent solids,
g/dL, and Scott’s concentration was
g/mL, the R-Z equation, using n
instead of 4.56, becomes,
Vs = Vso x (1-FV/100)n.
![Page 11: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/11.jpg)
Dick and Young used the log-log
equation to fit higher concentrations.
Vs = a * FV-n
![Page 12: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/12.jpg)
SETTLING AND UNDERFLOW
VELOCITY VS. FLOC VOLUME
0.01
0.10
1.00
10.00
10 100 1000
Floc Volume, DSVI*C, Percemt
Se
ttlin
g V
elo
cit
y a
nd
Un
de
rflo
w V
elo
cit
y, m
/hr
(100 - FV)
U vs Xu, POWER
U vs Xu, EXP.
Sims Bayou
Thickener
Richardson & Zaki
![Page 13: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/13.jpg)
POWER EQUATIONS FITTED
TO THE SETTLING DATA
• For FV < 40,
• Vs = 8.58 * (1 - FV/100)3.83 m/hr
• For FV > 40,
• Vs = 15,300 * FV-2.56 m/hr
![Page 14: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/14.jpg)
EXPONENTIAL EQUATION
FITTED TO THE SETTLING
DATA
• Vesilind proposed plotting the
logarithm of the settling velocity
against the arithmetical value of
concentration. This gives a
single exponential equation.
• Vs = 9.38 * exp(-0.0494*FV) m/hr
![Page 15: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/15.jpg)
Exponential Correlation of
Settling Velocity and Floc Volume
0
0
1
10
0 10 20 30 40 50 60 70 80 90 100
FLOC VOLUME, PERCENT
SE
TT
LIN
G V
EL
OC
ITY
, m
/hr
![Page 16: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/16.jpg)
Formulas At A Settling Tank
1. (V + U)*FV = U*FVuThis is limited by,
2. (Vs + U)*FV = U*FVu How can we rearrange this to
plot the relationships?
![Page 17: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/17.jpg)
Limiting Formulas At The Settling
Tank
2. (Vs + U)*FV = U*FVu Multiply left side of equation.
3. Vs*FV + U*FV = U*FVuVelocity times Concentration
is a FLUX by definition.
![Page 18: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/18.jpg)
Preparing a total flux plot
• Label ordinate as FLUX, m/hr * Floc
Volume
• Label abscissa as Floc Volume = FV,%
• Plot U*FV vs FV, a straight line from 0,0
• Fit an equation to the settling data,
Vs=f(FV)
• From the equation, plot Vs*FV vs FV
![Page 19: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/19.jpg)
3. Vs*FV + U*FV = U*FVu
Total Flux Versus FV Plot
• The concern is for the Floc Volume as it increases from Feed FV to Underflow FV at the same Total Flux.
• If the Feed FV is less than FVB, the maximum flux is limited by the minimum in the Total Flux curve.
U=0.34 m/hr
0
20
40
60
80
0 25 50 75 100 125 150
Feed Floc Volume, percent
Flo
c V
olu
me F
lux, F
V x
m/h
r
Total Flux (Vr+U) Flux
Underflow Flux FVB
Vr Ext. Underflow FV
![Page 20: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/20.jpg)
3. Vs*FV + U*FV = U*FVu
Total Flux Versus FV Plot
• If the Feed FV is greater
than FVB, the Total Flux
is limited only by the
Total Flux curve.
• The Underflow FV will
be greater than the value
obtained when Feed FV
is less than FVB.
U=0.34 m/hr
0
20
40
60
80
0 25 50 75 100 125 150
Feed Floc Volume, percent
Flo
c V
olu
me F
lux, F
V x
m/h
r
Total Flux (Vr+U) Flux
Underflow Flux FVB
Vr Ext. Underflow FV
![Page 21: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/21.jpg)
3. Vs*FV + U*FV = U*FVu
Total Flux Versus FV Plot
Result when Loading Point is in the various areas
• C. On (Vr+U) curve it issteady state. Below the curve, no blanket forms, existing is depleted
• B. Thick blanket forms at conc. FVB. Thin blanket, if any, settles into the thick blanket.
• A. Thin blanket forms at feed solids concentration also thick blanket forms if FV is less than FVB.
C
B
A
U=0.34 m/hr
U=0.34 m/hr
A
B
C
![Page 22: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/22.jpg)
3. Vs*FV + U*FV = U*FVu
Total Flux Versus FV Plot
Result when State Point is in the various areas
• If a sludge blanket
persists, the State
Point is either on or
oscillates around the
green line of (Vr+U)
Flux.C
B
A
U=0.34 m/hr
A
B
C
U=0.34 m/hr
![Page 23: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/23.jpg)
3. Vs*FV + U*FV = U*FVu
Yoshioka Flux Plot
0
20
40
60
80
0 25 50 75 100 125 150
Feed Floc Volume, percent
Flo
c V
olu
me F
lux, F
V x
m/h
r
Settling Flux, FV*m/h Vr Flux, FV*m/h
FVB Vr Ext
Underflow FV
• The Settling Flux is plotted versus the Feed Floc Volume.
• For Feed FV < FVB, the Maximum Flux that can be removed is shown by a line with slope –U tangent to the Settling Flux curve.
U=0.34 m/hr
![Page 24: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/24.jpg)
3. Vs*FV + U*FV = U*FVu
Yoshioka Flux Plot
Result when State Point is in the various areas
U=0.34 m/hr
C. On Vr curve it is steady
state. Below the curve, no
blanket forms, existing is
depleted.
B. Thick blanket forms at
conc. FVB. Thin blanket, if
any, settles into the thick
blanket.
A. Thin blanket forms at
feed solids concentration
plus thick blanket if FV is
less than FVB.
AB
C
![Page 25: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/25.jpg)
3. Vs*X + U*X = U*Xu
Yoshioka Flux Plot
![Page 26: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/26.jpg)
YOSHIOKA Et Al.
FLUX PLOTS
![Page 27: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/27.jpg)
Alternate Limiting Formulas At
The Settling Tank
3. (Vs + U)*FV = U*FVu
Divide by FV, subtract U
4. Vs = U*FVu*(1/FV) – U
Plot Vs versus (100/FV)
Plot U on the Y-axis
![Page 28: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/28.jpg)
4. Vs = U*FVu*(1/FV) - U
Velocity Versus 100/FV Plot
ABA
C. No blanket forms,
existing is depleted. The
only steady states are on
the Vr max curve.
B. Thick blanket forms.
Thin blanket, if any, settles
into the thick blanket.
A. Thin blanket forms at
feed solids concentration
plus thick blanket 1/Xu
1/Xb
AB
C
A B
C
![Page 29: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/29.jpg)
Real, non-steady state equation
• (U + V) FV = U FVu + rate of
change in sludge blanket
• If the rate of change of the blanket
is zero, V becomes Vrmax.
• (U+Vrmax)FV = U FVu
• Vrmax = U FVu(1/FV) - U
![Page 30: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/30.jpg)
4. Vrmax = U*FVu*(100/FV) - U
• Points on a velocity
vs. reciprocal of
concentration chart
indicate the derivative
of the sludge blanket
height, NOT the
blanket height.
![Page 31: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/31.jpg)
Results of Blanket Formation
• In an activated sludge plant, formation of a sludge blanket in the settler depletes solids in the mixed liquor aeration tank.
• The change in feed solids depends on the size and arrangement of aeration tanks.
• Due to the dynamics of the process a simulation program is needed to follow the changes in blanket height from storm flow.
![Page 32: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/32.jpg)
Danger!
Sedimentation programs that do not have
mixed liquor aeration tanks are worthless!
In an activated sludge plant, formation of a
sludge blanket in the settler depletes solids
in the mixed liquor aeration tank and
reduces the solids in feed to the settler.
![Page 33: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/33.jpg)
Review of Coe And Clevenger,
1916
C = 62.35 R/(F – D)
C = capacity in pounds per sq. foot per hour.
R = rate of settling in feet per hour at
consistency F.
F = ratio of fluid to solids in pulp tested.
D = ratio of fluid to solids in discharge req’d.
![Page 34: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/34.jpg)
Coe And Clevenger
C = 62.35 R/(F – D)
Upper chart
R= C(F – D)/62.35
Lower chart, line added
![Page 35: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/35.jpg)
Coe And Clevenger, Figure 6
![Page 36: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/36.jpg)
Coe And Clevenger, Figure 13
![Page 37: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/37.jpg)
Coe and Clevenger
• The chart illustrates the
calculation of C for point j
at F=3.0, R=0.62, and
D=1.0
• C=62.35*0.62/(3-1)=19.3
• The calculation may be
repeated for each point for
the Capacity Curve, or
• Since the line is tangent to
the curve, it is the Capacity
Replot of Figure 13.
0
0.5
1
1.5
2
2.5
3
3.5
4
0246810
Consistency, lb H2O/lb pulp
R, ft
/hr
F D
R
![Page 38: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/38.jpg)
Coe and Clevenger
Omitting the weight of water per cubic foot,
R = C*(F-D)/62.35 is equal to
• V= U*Xu*(1/X – 1/Xu)
• V= U*Xu*1/X – U*Xu/Xu
• V= U*Xu*(1/X) – U
• Thus the Coe and Clevenger lower chart is
equivalent to the Velocity vs 1/X plot.
• The line may be started from the underflow
rate or 1/underflow concentration.
![Page 39: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/39.jpg)
Discussion
• Coe and Clevenger called X*Xu the capacity of a thickener, not the limiting flux.
• The term flux was later applied to the product of concentration and velocity to aid in the explanation of the thickening phenomenon.
• The mathematics is the same regardless of the name applied to the terms.
![Page 40: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/40.jpg)
Summary
• The Flux Curve is not theory, but an analytical tool. You can use it to see the effect of various operating conditions.
• The curve of V vs Reciprocal of X has real coordinates and the flux terminology is not required.
• The plots of Total Flux vs X and the V vs Reciprocal of X have origins in the paper by Coe and Clevenger, 1916.
![Page 41: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/41.jpg)
Deviations
• If the sludge blanket gets into the underflow
then the underflow concentration is less
than predicted and extra solids accumulate
in the settling tank.
• Sawyer, Two Rivers WI Plant
• Munch, Calumet IL Plant
• Billmier, use deeper scraper blades
![Page 42: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/42.jpg)
Operation Problem
Municipal plants must treat high flow
during rain storms, bypass not allowed.
The plant must be operated so that high
flow can be received without upset.
The problem requires a dynamic
solution, therefore a simulation model
aids understanding of the solutions.
![Page 43: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/43.jpg)
Solution
The City of Houston and The University of Texas conducted research at the city’s 12 MGD Turkey Creek plant.
The research is reported in the Masters Thesis of William T. Manning, Jr. and in WER, July/Aug 1999, p 234.
The original 1.2 MGD plant (idle) was modified for the study and effluent was returned to the main plant.
A spreadsheet model was developed to simulate operating results.
![Page 44: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/44.jpg)
DESCRIPTION OF PLANT
USED FOR STUDY
Aeration Tanks, two at 26,880 cf each,
operated in series.
Clarifier, circular,13.5 side water depth,
area 4,800 sf.
An idle aeration basin of the main plant
was used to store effluent for storm flow
simulation.
![Page 45: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/45.jpg)
SCHEMATIC OF WASTEWATER FLOW
![Page 46: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/46.jpg)
Test Initial Conditions
0
10,000
20,000
30,000
40,000
50,000
60,000
0 50 100 150 200
FV
Flo
c V
olu
me
Flu
x, g
pd
/sf
*FV
Floc Vol. Flux Curve Tests, Initial FV FluxU=100 gpd/sf U=200 gpd/sfU=300 gpd/sf
8/23
8/27
![Page 47: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/47.jpg)
Power Equations Fitted To
Settling Data
• For FV < 40,
• Vs = 8.58 * (1 - fv/100)^3.83 m/h
• For FV > 40,
• Vs = 15,300 * fv^-2.56 m/h
![Page 48: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/48.jpg)
Exponential Equation Fitted
To Settling Data
• Vs = 9.38 * exp(-0.0494*FV) m/h
![Page 49: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/49.jpg)
Comparison Of Power And
Exponential Flux Curves
8/23
8/27
0
10
20
30
40
50
60
70
80
90
0 20 40 60 80 100 120 140 160
Floc Volume, DSV30, percent
Flo
c V
olu
me
Flu
x, D
SV
30
*m/h
Flux Curve, Power Flux Data Flux Curve, Exponential
![Page 50: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/50.jpg)
Test Results 8/23
V=2.12 M/h, U=0.42 M/h, FV=24%
Note: Overflow Rate Less Than Settling Rate, Model Tracks Blanket
-0.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
0 1 2 3 4 5 6
Time From Start, Hours
Bla
nket
Heig
ht,
m
-1
0
1
2
3
4
5
6
Sett
lin
g a
nd
Overf
low
Rate
s, m
/h
Bkt. Sl. Judge BLKT-MODEL 1
Settling Rate Overflow Rate
![Page 51: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/51.jpg)
A Flux Plot of Manning Test 8/23
Figure 1. Floc Volume Flux Curve
0
10
20
30
40
50
60
70
80
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
Floc Volume, percent
Flo
c V
olu
me F
lux,
Settling Flux, FV*m/h Vr Flux, FV*m/h Storm Result 1st hr
Storm Result 2nd hr Storm Result 3rd hr Storm Result 4+ hrs
"Start of Storm" VrExt
Garrett et al, DSVI POWER EQ UR OK
![Page 52: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/52.jpg)
Test Results 8/27
V=2.54 M/h, U=0.34 M/h, FV=38%
Note: Overflow Rate Exceeds Settling Rate, Model I Does Not
Track the Blanket
0.0
0.5
1.0
1.5
2.0
0 1 2 3 4 5 6
Time From Start, Hours
Bla
nk
et
He
igh
t, m
0
1
2
3
4
5
6
Se
ttlin
g a
nd
Ov
erf
low
Ra
tes
,
m/h
Bkt. Sl. Judge Bkt Meter Bkt. Model 1
Settling Rate Overflow Rate
![Page 53: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/53.jpg)
A Flux Plot of the Manning Test 8/27
Figure 1. Floc Volume Flux Curve
0
20
40
60
80
100
120
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
Floc Volume, percent
Flo
c V
olu
me F
lux,
Settling Flux, FV*m/h Vr Flux, FV*m/h Storm Result 1st hr
Storm Result 2nd hr Storm Result 3rd hr Storm Result 4+ hrs
"Start of Storm" VrExt
Garrett et al, DSVI POWER EQ UR OK
![Page 54: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/54.jpg)
4. Vrmax = U*FVu*(100/FV) - U
• Model I did not
consider Vo>Vs and
formation of a thin
blanket.
• Model II by Manning
includes formation
of a thin blanket at
rate dHa/dt = Vo-Vs
![Page 55: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/55.jpg)
Test Results 8/27 + Model 2
V=2.54 M/h, U=0.34 M/h, FV=38%
Note: Model 2 (With Ha) Tracks the Blanket Height
0.0
0.5
1.0
1.5
2.0
0 1 2 3 4 5 6
Time From Start, Hours
Bla
nket
Heig
ht,
m
Bkt. Sl. Judge Bkt. Model 2, Power Bkt Meter
![Page 56: Who’s Afraid of the Settling Flux?](https://reader033.vdocument.in/reader033/viewer/2022042318/625cd8fa5eefd84da8079960/html5/thumbnails/56.jpg)
Summary
• The use of the spreadsheet with
Model II allows rapid evaluation of
the effect of storm flows. The safe
maximum floc volume may be
determined for the peak overflow rate
and the maximum allowable sludge
blanket height. This may exceed the
Flux Curve.