wl12 b5681 sensor
TRANSCRIPT
-
7/21/2019 Wl12 b5681 Sensor
1/18
Supply voltage 10 to 30 V.
Insensitive to ambient light due topulse modulation.
Complementary switching outputs forlight of dark switching with short-circuit
protection in NPN or PNP models.
Available as through-beam photo-electric switch, photoelectric reflexswitch, photoelectric proximity switch.
Photoelectric Switches
W12-2 Series
D A T A S H E E T
WL 12-2
WT 12-2
v
xWS/WE 12-2
0 ... 7 m
20 m
Photoelectric switches in stable metalhousing. Photoelectric proximityswitches WT 12-2 with stepless adjust-able scanning distance and optionalbackground or foreground suppressionas well as sensitivity adjuster for large
scanning distances. Polarization filterfor WL 12-2 photoelectric proximityswitch.
WS/WE 12-2 through-beam photo-electric switches with test input forfunction monitoring.
LED signal strength indicator for soilingmonitoring of the optics and asalignment help (blinking).
Available with fixed attached cable or4 pole equipment plug.
35 ... 150 mm
20 ... 250 mm
Variable connection options on theback and bottom thanks to rotableequipment plug.
n80 ... 600 mm
Flexible mounting options thanks todovetail clamp and longitudinal holes.
-
7/21/2019 Wl12 b5681 Sensor
2/18
2
SICK
OPTIC-E
LECTRONIC
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
2
32
M12x1
11,2
LED signal strength indicator
2 Center of optical axis
3 Mounting holes
4 Threaded mounting hole M 4 4 deep
5 Plug M 12 (rotatable by 90)or 2 m connection cable
6 Sensitivity adjuster
2
6
5
Connection diagram
x20 m
Scanning Range
WS/WE 12-2
brn blu wht blk
brown blue white black
braun blau wei schwarz
Features:
Red-light emitter LED asalignment aid
Insensitive to ambient lightsources (HF lamps, blinking alarmlights)
Reliable functioning when devices
mounted facing each other Switching frequency 1.5 kHz
All-round reverse polarityprotection at the inputs andoutputs
Outputs short-circuit protected
90 rotatable M 12 equipmentplug or 2 m cable
C
1
3
4
1
4
2
3
+10...30 V+10...30 V
0V0V
TestTest
+10...30 V+10...30 V
QQ
QQ
0V0V
0 V
Test
+V
Q
+V
Q
Q
0 V 0 V
Q
brn
blu
wht
brn
blk
wht
blu
WS 12-2
WE 12-2-N -P
RL
RL
RL
RL
20 4 6 8 10 12 14 16 18 20
10
1000
10000
100
1
y
x [m]
WS/WE 12-2
Operatingreserve
Scanning range (m)
4
3
-
7/21/2019 Wl12 b5681 Sensor
3/18
3
SICK
OPTIC-E
LECTRONIC
Through-beam Photoelectric SwitchWS/WE 12-2
1) At TU= + 25C
2) Must remain within VStolerances
3) At TU= + 25C and 100 mA output current
4) Signal run time with resitive load5) With light/dark ratio 1:1
Type WS/WE 12-2 -P -NTypical maximal range 20 m
Recommended operating range 15 m
Range with 2 mm orifice 2.0 m
Range with 1.5 mm orifice 1.5 m
Range with 1 mm orifice 1.0 m
Range with 0.5 mm orifice 0.5 m
Light source LED, visible red light, average operating life 100 000 h 1)
Light spot in distance 400 mm at distance of 15 m
Supply voltage VS DC 10 ... 30 V (Limit values)
Current consumption (without load) 15 mA, WE; 30 mA, WS 25 mA, WE; 30 mA, WS
Ripple2) 5 VPP
Switching outputs PNP, Q and Q NPN, Q and Q
Signal voltage HIGH VS 2.9 V VS
Signal voltage LOW3) approx. 0 V 1.5 V
Output current IAmax. 100 mA
Response time4), Switching frequency5) 330 s; 1500/s
Test input TI VSor unswitched, Sender active
0 V Sender inactive
VDE protection class6) V
Enclosure rating IP 67
Protection circuits7) A, B, C
Ambient operating temperature TU8) 40 ... + 60 C
Storage temperature TL8) 40 ... + 75 C
Weight with equipment plug 120 g, with cable approx. 200 g
6) Withstand voltage 50 V7) A = Inputs and outputs all-round reverse polarity protected
B = Outputs short-circuit protectedC = Interference pulse suppression
8) Do not deform connecting cable below 0 C
Selection Table
Plug M 12 Cable Transistor output Type Order no.rotatable 2 m PNP NPN
WS/WE 12-2P430 1 016 157
WS/WE 12-2N430 1 016 155
WS/WE 12-2P130 1 016 156
WS/WE12-2N130 1 016 154
-
7/21/2019 Wl12 b5681 Sensor
4/18
4
SICK
OPTIC-E
LECTRONIC
Connection Diagram
v0 ... 7 m
Scanning Range
WL 12-2
brn blk blu wht
brown black blue white
braun schwarz blau wei
2
5
6
Features:
Red-light emitter LED asalignment aid
Insensitive to ambient light (HFlamps, blinking alarm lights)
Reliable functioning when devicesmounted facing each other
Switching frequency 1.5 kHz All-round reverse polarity
protection at inputs and outputs
Outputs short-circuit protected
90 rotatable M 12 equipmentplug or 2 m cable
C
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
2
32
M12x1
11,2
4
3
0,50 1 1,5 2 2 ,5 3 3 ,5 4 4,5 5 5,5 6 6,5 7
10
1000
100
1
Diam. Grade/1 m
PL20A/2 m
PL80A/5 m
PL30A/3 m
C110/3 m
PL50A/3,5 m
PL40A /3,5 m
y
yB
yG
x [m]
Scanning range (m)
WL 12-2
1
4
2
3
+10...30V+10...30V
QQ
QQ
0V0V
+VRLQ
+V
RL
Q
Q
RL
0V0VRL
Q
brn
blk
wht
blu
-N4
-P4
WL 12-2 -N1
-P1
-N
NPN
-P
PNP
LED signal strength indicator
2 Center of optical axis
3 Mounting holes
4 Threaded mounting hole M 4 4 deep
5 Plug M 12 (rotatable by 90)or 2 m connection cable
6 Sensitivity adjuster
Operatingreserve
-
7/21/2019 Wl12 b5681 Sensor
5/18
5
SICK
OPTIC-E
LECTRONIC
Photoelectric Reflex SwitchWL 12-2
1) Must remain within VStolerances
2) At TU= + 25 C
3) At TU= + 25 C and 100 mA output current
4) Signal run time with resitive load
Selection Table
Standard (f = ) Focus (f = 90 mm) Standard (f = ) Focus (f = 90 mm)
Typical maximal range/on reflector 7 m/PL 80 A 2 m/PL 80 A 7 m/PL 80 A 2 m/PL 80 A
Recommended operating range
With reflector PL 80 A 0 ... 5 m 0 ... 1.5 m 0 ... 5 m 0 ... 1,5 m
With reflector C 110 0 ... 3 m 0 ... 3 m
With reflector PL 50 A 0 ... 3.5 m 0 ... 3.5 m
With reflector PL 40 A 0 ... 3.5 m 0 ... 3.5 m
With reflector PL 30 A 0 ... 3 m 0 ... 3 m
With reflector PL 20 A 0 ... 2 m 0 ... 2 m
with Diamond grade reflective tape 0 ... 1 m 0 ... 0.5 m 0 ... 1 m 0 ... 05 m(min. 100 x 100 mm2area)
Supply voltage VS DC 10 ... 30 V
Current consumption (without load) 30 mA 40 mA
Ripple1) 5 VPP
Light source LED, visible red light, average operating life 100 000 h 2)
Angle of dispersion approx. 1,5
Light spot diameter 80 mm at distance 2 mm at distance 80 mm at distance 2 mm at distanceof 3 m of 90 mm of 3 m of 90 mm
Switching outputs PNP, Q and Q NPN, Q and Q
Signal voltage HIGH VS 2,9 V VS
Signal voltage LOW3) approx. 0 V 1,5 V
Output current IAmax. 100 mA
Response time4); max. signal frequency5) 330 s; 1000/s
VDE protection class6) V
Enclosure rating IP 67
Protection circuits7) A, B, C
Ambient operating temperature TU8) 40 ... + 60 C
Storage temperature TL8) 40 ... + 75 C
Weight with equipment plug approx. 120 g, with connection cable approx. 200 g
5) With light/dark ratio 1:16) Withstand voltage 50 V
7) A = Inputs and outputs all-round reverse polarity protectedB = Outputs short-circuit protectedC = Interference pulse suppression
8) Do not deform connecting cable below 0 C
WL 12-2 -P -N
Lens Cable M 12 plug Transistor output Type Order no.2 m rotable PNP NPN
Standard (f = ) WL 12-2N130 1 016 085
WL 12-2P130 1 016 096
WL 12-2N430 1 016 092
WL 12-2P430 1 016 102
Focus (f = 90 mm) WL 12-2N120 1 016 084
WL 12-2P120 1 016 095
WL 12-2P420 1 016 091
WL 12-2P420 1 016 101
-
7/21/2019 Wl12 b5681 Sensor
6/18
6
SICK
OPTIC-E
LECTRONIC
Connection Diagram
v0 ... 4 m
Scanning Range
gra brn blu blk wht
gray brown blue black white
grau braun blau schwarz wei
Features:
Detection of glass and transpa-rent film
Red-light emitter LED asalignment aid
Insensitive to Amibient lightsources (HF lamps, flashing
alarm lamps) Reliable functioning when devices
installed facing each other
Switching frequency 1.5 kHz
All-round reverse polarityprotection at the inputs andoutputs
Outputs short-circuit protected
90 rotatable M 12 equipmentplug or 2 m cable
C
WL 12-2B560
Scanning range (m)
WL 12-2B
0,50 1 1,5 2 2,5 3 3,5 4 4,5 5
10
100
1
PL30A/2 m
PL50A/2,5 m
y
x [m]
PL80A/3 m
LED signal strength indicator
2 Center of optics axis
3 Mounting holes
4 Threaded mounting hole M 4 4 deep
5 Plug M 12 (rotatable by 90)or 2 m connection cable
6 Sensitivity adjuster
Operatingreserve
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
2
32
M12x1
11,2
4
3
2
5
6
0 V
RLQP
RL
+V
0 V
L / D
+V
L / D
4 blk
2 wht
5 gra
3 blu
1 brn
WL 12-2B560
0 V
+10 ... 30 V
QP
QNQN
L / D
light-switching dark-switching
-
7/21/2019 Wl12 b5681 Sensor
7/18
7
SICK
OPTIC-E
LECTRONIC
Photoelectric Reflex SwitchWL 12-2B560
with small Switching Hysteresis
1) Must remain within VStolerances
2) At TU= + 25 C
3) At TU= + 25 C and 100 mA output current
4) Signal run time with resistive load5) With light/dark ratio 1:16) Withstand voltage 50 V
7) A = Inputs and outputs all-round reverse polarity protectedB = Outputs short-circuit protectedC = Interference pulse suppression
8) Do not deform connecting cable below 0 C
WL 12-2 B560Part No. 1 016 080
Typ. maximal range/on reflector 4 m/PL 80 A
Recommended operating range
With reflector PL 80 A 0 ... 3.5 m
With reflector C 110 0 ... 1.8 m
With reflector Pl 50 A 0 ... 2.0 m
With reflector PL 40 A 0 ... 1.8 m
With reflector PL 30 A 0 ... 1.6 m
With reflector PL 20 A 0 ... 1.0 m
With Diamond grade reflective tape 0 ... 0.5 m(min. 100 x 100 mm2area)
Supply voltage VS DC 10 ... 30 V
Current consumption (without load) 30 mA
Ripple1) 5 VPP
Light source LED, visible red light, average operating life 100 000 h 2)
Angle of dispersion approx. 1.2
Light spot diameter 30 mm at distance of 1.5 m
Switching outputs QP+ QN Output OP PNP Output QN NPN
Signal voltage HIGH VS 2.9 V VS
Signal voltage LOW approx. 0 V 1.5 V
Output current IAmax. 100 mAOperating mode Light- or dark-switching, via control cable L/D switchable
Control input L/D 0 V or unswitched light-switching
Control input L/D VS dark-switching
Response time4), Switching frequency, max.5) 330 s; 1500/s
VDE protection class6) V
Enclosure rating IP 67
Protection circuits7) A, B, C
Ambient operating temperature TU8) 40 ... + 60 C
Storage temperature TL8) 40 ... + 75 C
Weight approx. 120 g
-
7/21/2019 Wl12 b5681 Sensor
8/18
8
SICK
OPTIC-E
LECTRONIC
Connection Diagram
v0 ... 7 m
Scanning Range
WL 12-2 ASI
Features:
Red-light emitter LED asalignment aid
Insensitive to ambient light (HFlamps, blinking alarm lights)
Reliable functioning when devicesmounted facing each other
Switching frequency 1.5 kHz Inputs reverse polarity
protected
90 rotatable M 12 equipmentplug
C
Scanning range (m)
WL 12-2 ASI
0,50 1 1,5 2 2 ,5 3 3,5 4 4,5 5 5,5 6 6,5 7
10
1000
100
1
Diam. Grade/1 m
PL20A/2 m
PL80A/5 m
PL30A/3 m
C110/3 m
PL50A/3,5 m
PL40A /3,5 m
y
yB
yG
x [m]
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
2
32
M12x1
11,2
4
3
2
5
6
LED signal strength indicator
2 Center of optical axis
3 Mounting holes
4 Threaded mounting hole M 4 4 deep
5 Plug M 12 (rotatable by 90)or 2 m connection cable
6 Sensitivity adjuster
Operatingreserve
WL 12-2Z430
1
3
-
7/21/2019 Wl12 b5681 Sensor
9/18
9
SICK
OPTIC-E
LECTRONIC
Photoelectric Reflex SwitchWL 12-2 ASI
1) At TU= + 25 C
2) Signal run time of sensor3) With light/dark ratio 1:14) Withstand voltage 50 V5) A = Inputs reverse polarity protected
C = Interference pulse suppression6) Do not deform connecting cable below 0 C
WL 12-2 -Z430Part No. 1 016 108
Typ. maximal range/on reflector 7 m/PL 80 A
Recommended operating range
With reflector PL 80 A 0 ... 5 m
With reflector C 110 0 ... 3 m
With reflector Pl 50 A 0 ... 3.5 m
With reflector PL 40 A 0 ... 3.5 m
With reflector PL 30 A 0 ... 3 m
With reflector PL 20 A 0 ... 2 m
With Diamond grade reflective tape 0 ... 1 m(min. 100 x 100 mm2area)
Supply voltage VS DC 26,5 ... 31.6 V
Current consumption 35 mA
Light source LED, visible red light, average operating life 100 000 h 1)
Angle of dispersion 1.5
Light spot diameter 80 mm at distance of 3 mm
Response time2), Switching frequency max.3) 330 s; 1500/s
VDE protection class4) V
Enclosure rating IP 67
Protection circuits5) A, C
Ambient operating temperature TU6)
25 ... + 60 CStorage temperature TL
6) 40 ... + 75 C
Weight approx. 120 g
* Default setting 0 1
Allocation Data bits(Host level) Allocation Parameter bits(Host level)
D0
Switching state 0 no reflection Input1 reflection
D1 VMA 0 active Input1 inactive
D2
NC 0 Input1
D3* Test function 0 sender on Output1 sender off
P0* NC 0 Parameter
1
P1* Light-/dark- 0 Dark-switching Parameter switch 1 Light-switching
P2* NC 0 Parameter
1
P3* NC 0 Parameter 1
-
7/21/2019 Wl12 b5681 Sensor
10/18
10
SICK
OPTIC-E
LECTRONIC
Connection Diagram
35 ... 150 mm
Adjustable Scanning Distance
WT 12-2
2
3
7
6
LED signal strength indicator
2 Optical axis Receiver
3 Optical axis Sender
4 Mounting holes
5 Threaded mounting holes M 4 4 deep
6 M12 plug (rotable by 90)or 2 m connection cable
7 Scanning distance adjuster
Features:
Red-light emitter LED asalignment aid
Foreground suppression
Adjustable scanning distance
Insensitive to ambient light (HFlamps, blinking warning lights)
Reliable functioning with devicesfacing each other
Switching frequency 1.5 kHz
All-round reverse polarityprotection at the inputs andoutputs
Outputs short-circuit protected
90 rotable M 12 equipmentplug or 2 m cable
C
brn blu blk wht
brown blue black white
braun blau schwarz wei
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
30
,4
15
M12x1
11,2
5
4
1
4
2
3
+10...30V+10...30V
QQ
QQ
0V0V
+VRLQ
+V
RL
Q
Q
0V0V
RL
Q
brn
blk
wht
blu
-N4
-P4
WT 12-2 -N1
-P1
-N
NPN
-P
PNP
RL
Set scanning distance (mm)
WT 12-2
0
x [mm]
y [%]
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
20 40 8060 10030 50 70 90
90% / 90%
18% / 90%
6% / 90%
Scanningdisplacement
-
7/21/2019 Wl12 b5681 Sensor
11/18
11
SICK
OPTIC-E
LECTRONIC
Photoelectric Proximity SwitchWT 12-2
with Foreground Suppression
1) Object with 6 % reflection(based on white standard to DIN 5033)
2) Limit value3) Must remain within V
Stolerances
4) At TU= + 25 C5) At T
U= + 25 C and 100 mA output current
6) Signal run time with resitive load
WT 12-2 -P -N
Selection Table
Scanning range, adjustable 1) 35 ... 150 mm
Supply voltage VS2) DC 10 ... 30 V
Current consumption (without load) 30 mA 40 mA
Ripple3) 5 VPP
Light source LED, visible red light, average operating life 100 000 h 4)
Light spot diameter 2 mm at distance of 60 mm
Switching outputs PNP, Q and Q NPN, Q and Q
Signal voltage HIGH VS2,9 V VS
Signal voltage LOW3) approx. 0 V 1,5 V
Output current IA
max. 100 mA
Response time, max.6);switching frequency, max.7) 330 s; 1500/s
VDE protection class 8) V
Enclosure rating IP 67
Protection circuits9) A, B, C
Ambient operating temperatue TU10) 40 ... + 60 C
Storage temperatue TL10) 40 ... + 75 C
Weight with equipment plug approx. 120 g, with connection cable approx. 200 g
7) With light/dark ratio 1:18) Withstand voltage 50 V9) A = Inputs and outputs all-round reverse polarity protected
B = Outputs short-circuit protected
C = Interference pulse suppression10) Do not deform connecting cable below 0 C
M 12 plug Cable Transistor output Type Order no.rotable 2 m PNP NPN
WT 12-2P440 1 016 150
WT 12-2N440 1 016 146
WT 12-2P140 1 016 148
WT 12-2N140 1 016 145
-
7/21/2019 Wl12 b5681 Sensor
12/18
12
SICK
OPTIC-E
LECTRONIC
Connection Diagram
20 ... 250 mm
Adjustable Scanning Distance
WT 12-2
Features:
LED light source, visible red lightor infrared sender light
Background suppression
Adjustable scanning distance
Insensitive to ambient light (HFlamps, blinking warning lights)
Reliable functioning with devicesfacing each other
Switching frequency 1,5 kHz
All-round reverse polarityprotection at the inputs andoutputs
Outputs short-circuit protected
90 rotable M 12 equipmentplug oder 2 m cable
C
brn blu blk wht
brown blue black white
braun blau schwarz wei
1
4
2
3
+10...30V+10...30V
QQ
QQ
0V0V
+VRLQ
+V
RL
Q
Q
0V0V
RL
Q
brn
blk
wht
blu
-N4
-P4
WT 12-2 -N1
-P1
-N
NPN
-P
PNP
RL
Scanning distance (mm)
WT 12-2
20
22
y [%]
x [mm]
18
16
14
12
10
8
6
4
2
0
0 50 150100 200 250 300
6%/90%
18%/90%
90%/90%
LED signal strength indicator
2 Optical axis Receiver
3 Optical axis Sender
4 Mounting holes
5 Threaded mounting hole M 4 4 deep
6 Plug M 12 (rotatable by 90)or 2 m connection cable
7 Scanning distance adjuster
3
7
6
2
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
29
,9
21
,3
M12x1
11,2
5
4
Scanningd
istancedisplacement
-
7/21/2019 Wl12 b5681 Sensor
13/18
13
SICK
OPTIC-E
LECTRONIC
Photoelectric Proximity SwitchWT 12-2
with Background Suppression
1) Object with 6/18 % reflection
(based on white standard to DIN 5033)2) Must remain within V
Stolerances
3) AtuTU= + 25 C
4) At TU= + 25 C and 100 mA output current
5) Signal run time with resitive load6) With light/dark ratio 1:1
WT 12-2 -P -N
Selection Table
Scanning distance, adjustable1) 20 ... 250 mm
Scanning distance 5 ... 20 mm and 5 ... 250 mm
Supply voltage VS DC 10 ... 30 V (limit values)
Current consumption (without load) 40 mAinfrared/ 30 mArot 50 mAinfrared/ 40 mArot
Ripple2) 5 VPP
Light source LED, infrared or visible red light (see selection table),average operating life 100 000 h3)
Light spot diameter 10 mm at distance of 200 mm
Switching outputs PNP, Q and Q NPN, Q and Q
Signal voltage HIGH VS 2.9 V VS
Signal voltage LOW4) approx. 0 V 1.5 V
Output current IAmax. 100 mA
Response time, max.5);switching frequency, max.6) 330 s; 1500/s
VDE protection class7) V
Enclosure rating IP 67
Protection circuits8) A, B, C
Ambient operating temperature TU9) 40 ... + 60 C
Storage temperature TL9) 40 ... + 75 C
Weight with equipment plug approx. 120 g, with connection cable approx. 200 g
7) Withstand voltage 50 V
8) A = Inputs and outputs all-round reverse polarity protectedB = Outputs short-circuit protectedC = Interference pulse suppression
9) Do not deform connecting cable below 0 C
Cable M 12 plug Sender light Transistor output Type Order no.2 m rotable IR Red light PNP NPN
WT 12-2N110 1 016 118
WT 12-2P110 1 016 126
WT 12-2N410 1 016 124
WT 12-2P410 1 016 131
WT 12-2N130 1 016 122
WT 12-2P130 1 016 129
WT 12-2N430 1 016 125
WT12-2P430 1 016 134
-
7/21/2019 Wl12 b5681 Sensor
14/18
14
SICK
OPTIC-E
LECTRONIC
Connection Diagram
80 ... 600 mm
Adjustable Scanning Distance
WT 12-2
7
3
6
2
Features:
Red-light emitter LED asalignment aid
Adjustable scanning distance
Insensitive to ambient light (HFlamps, blinking warning lights)
Reliable functioning with devices
facing each other Switching frequency 1.5 kHz
All-round reverse polarityprotection at the inputs andoutputs
Outputs short-circuit protected
90 rotable M 12 equipmentplug or 2 m cable
C
brn blu blk wht
brown blue black white
braun blau schwarz wei
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
30
,5
22
,5
M12x1
11,2
5
4
Scanning distance (mm)
WT 12-2
100
y
x [mm]
ybm
10
110 100 1000
90%
90%
n
LED signal strength indicator
2 Optical axis Receiver
3 Optical axis Sender
4 Mounting holes
5 Threaded mounting hole M 4 4 deep
6 Plug M 12 (rotatable by 90)or 2 m connection cable
7 Scanning distance adjuster
1
4
2
3
+10...30V+10...30V
QQ
QQ
0V0V
+VRLQ
+V
RL
Q
Q
0V0V
RL
Q
brn
blk
wht
blu
-N4
-P4
WT 12-2 -N1
-P1
-N
NPN
-P
PNP
RL
Operatingreserve
-
7/21/2019 Wl12 b5681 Sensor
15/18
15
SICK
OPTIC-E
LECTRONIC
Phototelectric Proximity SwitchWT 12-2
energetic
WT 12-2 -P -N
Selection Table
Scanning distance, adjustable1) 80 ... 600 mm
Supply voltage VS DC 10 ... 30 V (limit values)
Current consumption (without load) 30 mA 40 mA
Ripple2) 5 VPP
Light source LED, visible red light, average operating life 100 000 h 3)
Light spot diameter 30 mm at distance of 600 mm
Switching outputs PNP, Q and Q NPN, Q and Q
Signal voltage HIGH VS 2.9 V VS
Signal voltage LOW4) approx. 0 V 1.5 V
Output current IA
max. 100 mA
Response time5), switching frequency max.6) 330 s; 1500/s
VDE protection class7) V
Enclosure rating IP 67
Protection circuits8) A, B, C
Ambient operating temperature TU9) 40 ... + 60 C
Storage temperature TL9) 40 ... + 75 C
Weight with equipment plug approx. 120 g, with connection cable approx. 200 g
1) Object with 90 % reflection(based on white standard to DIN 5033)
2) Must remain within VStolerances
3) At TU= + 25 C
4) At TU= + 25 C und 100 mA output current
5) Signal run time with resistive load6) With light/dark relationship 1:1
7) Withstand voltage 50 V8) A = Inputs and outputs reverse polarity protected
B = Outputs short-circuit protected
C = Interference pulse suppression9) Do not deform connecting cable below 0 C
Cable Plug M 12 Transistor output Type Order no.2 m rotable PNP NPN
WT 12-2N150 1 016 138
WT 12-2P150 1 016 140
WT 12-2N450 1 016 139
WT 12-2P450 1 016 142
-
7/21/2019 Wl12 b5681 Sensor
16/18
16
SICK
OPTIC-E
LECTRONIC
Connection Diagram
WT 12-2 ASI
Adjustable Scanning Distance
Features:
LED- light source with visiblered light
Background suppression
Adjustable scanning distance
Insensitive to ambient light (HFlamps, blinking alarm lights)
Reliable functioning when devicesmounting facing each other
Inputs reverse polarityprotected
Switching frequency 1.5 kHz
90 rotable M 12 equipmentplug or 2 m cable
C
20 ... 250 mm
Scanning distance (mm)
WT 12-2
3
7
6
2
41,515
49
,2
2
5,1
7,3
22,6
5,6
4,2
29
,9
21
,3
M12x1
11,2
5
4
LED signal strength indicator
2 Optical axis Receiver
3 Optical axis Sender
4 Mounting holes
5 Threaded mounting hole M 4 4 deep
6 Plug M 12 (rotatable by 90)or 2 m connection cable
7 Scanning distance adjuster
Scanningdistancedisplacement
20
22
y [%]
x [mm]
18
16
14
12
10
8
6
4
2
0
0 50 150100 200 250 300
6%/90%
18%/90%
90%/90%
WT 12-2Z430
1
3
-
7/21/2019 Wl12 b5681 Sensor
17/18
17
SICK
OPTIC-E
LECTRONIC
Photoelectric Proximity SwitchWT 12-2 ASI
with Background Suppression
WT 12-2 -Z430Part No. 1 016 136
Scanning distance, adjustable1) 20 ... 250 mm
Scanning range 5 ... 20 mm und 5 ... 250 mm
Supply voltage VS DC 26.5 ... 31.5 V
Current consumption 35 mA
Light source LED, visible red light, average operating life 100 000 h 2)
Light spot diameter 10 mm at distance of 200 mm
Response time3), max. switching frequency4) 330 s; 1500/s
VDE protection class V
Enclosure rating IP 67
Circuit protection5) A, B, C
Ambient operating temperature TU6) 25 ... + 60 C
Storage temperature TL6) 40 ... + 75 C
Weight approx. 120 g
1) Object with 90 % reflection(based on white standard to DIN 5033)
2) At TU= + 25 C
3) Signal run time of sensor4) With light/dark ratio 1:15) A = Inputs reverse polarity protected
C = Interference pulse protection6) Do not deform connecting cable below 0 C
Allocation Data bits(Host level)
D0
Switching state 0 No reflection Input1 reflection
D1 VMA 0 active Input1 inactive
D2
NC 0 Input1
D3* Test function 0 sender on Output1 sender off
Allocation Parameter bits(Host level)
P0* NC 0 Parameter
1
P1* Light/dark- 0 Dark-switching Parameter switching 1 Light-switching
P2* NC 0 Parameter
1
P3* NC 0 Parameter 1
* Default setting 0 1
-
7/21/2019 Wl12 b5681 Sensor
18/18
Great BritainErwin Sick
Optic-Electronic Ltd.Waldkirch House
39 Hedley Road, St. Albans
Hertfordshire AL1 5BN
Phone +44 17 27-83 11 21
Fax +44 17 27-85 67 678
008551.0498HJS
.BW
PrintedinGermanySubjecttochangewith
outpriornoticePrintedonchlorine-freebleached
paper
SICK
OPTIC-E
LECTRONIC
SICKOPTIC-E
LECTRONIC
USASick Optic-Electronic, Inc.6900 West 110th StreetBloomington, MN 55438Phone +1 612 941-67 80Fax +1 612 941-92 87WATS: 1-800-325-7425
Reflector PL 30 A (Order no. 1 002 314)
Accessories
Reflector PL 50 A (Order no. 1 000 132) Reflector PL 80 A (Order no. 1 003 865)
Reflector PL 20 A (Order no. 1 012 719)Reflector PL 40 A (Order no. 1 012 720)
Small mounting bracket for series W 12-2 (Order no. 2 012 938)
Large mounting bracket for series W 12-2 (Order no. 2 013 942)
Terminal clampfor series W 12-2(2 pieces required)(Order no. 2 013 285)
Double terminal clamp(Order no. 2 013 947)
Diamond GradeReflective Tape(Order no. 4 019 634)
Cable receptacle, angular5 polewith sprayed cable(Order no. 6 008 900)
Cable receptacle, straight5 pole with sprayed cable(Order no. 6 008 899)
Cable receptacle, angular(Order no. 6 007 303) DC
Cable receptacle, straight(Order no. 6 007 302) DC
AustraliaErwin Sick Optic-ElectronicPty. Ltd. Head Office, P.O. Box 214899 Heidelberg RoadIvanhoe, Vic. 3079AustraliaPhone +61 39 49 74 10 0
(0 08) 33 48 02 - toll freeFax +61 39 49 71 18 7