Seismic Design ASCE7 Part 1 by Ryan Freund • November 3, 2012 • 5 Comments ASCE 7 Seismic Design – Part 1 We are going to break down and review seismic design in regards to ASCE7-05. We are going to cover the basics and some commentary. Hopefully I will be able to elaborate sometime in the future and include some discussion. Based ASCE7-05 1) Exceptions a) Detached 1 and 2 family dwellings with a Ss<0.4 and SDC (Seismic Design Category) = A, B or C. b) Detached 1 and 2 family dwellings (not included above), wood framed, less than 2 stories, and designed in accordance with the IRC. c) Agricultural buildings d) Structures not included in ASCE7 such as bridges, transmission towers, nuclear, and buried structures. 2) Existing Structures – Alterations and additions a) See appendix 11B . b) To summarize – You have three options o i) Design the addition/alteration separately o ii) If the alteration/addition does NOT increase the seismic force or reduce the strength of the existing structural member(s) by more than 10% than you do NOT need to upgrade the existing member(s) to meet the current standard. o Upgrade the existing to meet the current standard (code) Seismic Loads First determine how the earth movement will influence the building and what acceleration should be used to model this movement. 1. Determine Ss and S1 from the 0.2 and 1.0s spectral response accelerations shown on Figs. 22-1 through 22-14. 2. Determine the Site Class based on soil properties. (See chapter 20 for more info on determining site classes). The site class shall be A,B,C,D,E,F based on the geotechnical report or local AHJ. If there has not been a site class provided site class D may be assumed (unless otherwise specified by AHJ). 3. Determine the appropriate site coefficient, Fa based on the short period, Ss, and Fv based on the 1sec period, S1, and the site class (Table 11.4-1 and 11.4-2).

Upload: jordan-rodriguez

Post on 06-Sep-2015

217 views

Category:

Documents


2 download

DESCRIPTION

wl_eq

TRANSCRIPT

  • Seismic Design ASCE7 Part 1 by Ryan Freund November 3, 2012 5 Comments

    ASCE 7 Seismic Design Part 1 We are going to break down and review seismic design in regards to ASCE7-05. We are going to cover the

    basics and some commentary. Hopefully I will be able to elaborate sometime in the future and include some

    discussion.

    Based ASCE7-05

    1) Exceptions

    a) Detached 1 and 2 family dwellings with a Ss

  • o Evaluate the Maximum Considered Earthquake (MCE) spectral response acceleration for short

    periods and 1 sec periods.

    Sms=Fa*Ss Sm1=FvS1

    4. Design Spectral Acceleration Parameters (these are the values used in design).

    o Sds=2/3*Sms (short period)

    o Sd1=2/3*Sm1 (1 s period)

    5. Determine Occupancy Category from Table 1-1

    6. Determine Importance Factor from Table 11.5-1

    7. Determine Seismic Design Category (SDC) A,B,C ,D, E or F. (E is reserved for S1>0.75 and F is

    reserved for Occupancy Category IV w/ S1>0.75) based occupancy category and period response

    acceleration parameter.

    o Table 11.6-1 SDC based on Sds

    o Table 11.6-2 SDC based Sd1

    o Use the most severe case. It is permitted to use Table 11.6-1 if S1 < 0.75 and all of the following

    apply:

    1. Unless Ta

  • o Omega: The Overstrength factor increases the required seismic forces and is applied in specific cases or in the design of certain parts of the structure. 0 is intended to reflect the upper bound lateral strength of the structure and estimates the maximum forces in elements that

    are to remain non-yielding during the design basis ground motion. In summary, R reduces the

    required seismic forces realizing the some yielding of the structure will help dissipate energy. To

    force a more ductile response some brittle members are designed to resist higher forces so that

    they stay in the elastic range during the seismic event.

    o (Cd) Deflection Amplification Factor: Realizing that the structure is intended to yield (ductile

    response) deflection will be greater than that found from an elastic analysis. Cd amplifies the

    deflection of the structure based on an elastic analysis.

    o

    Response Factor, Deflection Amplification Factor and Overstrength Factor

    2. Different systems may be used in the same structure. If the systems are in orthogonal directions the R,

    Omega, Cd shall be applied to each system. Systems used in combination to resist lateral forces in the

    same direction are referred to as dual systems. Some dual systems are listed in Table 12.2-1. For other

    systems the more stringent system limitation shall apply.

    o If R, C and vary over the height of the structure; the story below shall meet the most stringent of the stories above (avoid weak story) for systems in the same direction.

    There are multiple exceptions see (12.2.3.1) o If R, C and vary within the same story (Horizontal Combinations). R shall be the lowest of the

    different systems for that story. R may vary for different lines of LFRS if the building category is 1

    or 2, two stories or less and the use of flexible diagrams. However the diaphragm shall use the

    lowest R value. Cd and Omega in the direction under consideration under consideration at any

    story shall not be less than the largest value of this factor for the R factor used in the same

    direction being considered.

    o Further restrictions and direction is given in 12.2.5 for specific system requirements.

    3. Irregularities Irregularities are covered in chapter 12.3. They are specific to certain geometries and

    mass distributions.

    o Vertical Irregularities Differences from story to story including

    Variable stiffness, variable weight distribution, offset of vertical elements.

    o Horizontal Irregularities Reentrant corners, torsional, discontinuous diaphragms,

    non parallel systems.

    4. Redundancy Factor, equal to 1 for the following: o Structures assigned to SDC B or C

    o Calculating drift and P-Delta effects.

  • o Design of nonbuilding structures

    o Design of collector elements, splices and connections when using the overstrength factor.

    o Diaphragm loads using Eq 12.10-1

    o Structures with damping systems (Section 18).

    5. Redundancy Factor, equal to 1.3 for SDC D,E and F. Unless the exceptions of 12.3.4.2 are met and comply with table 12.3-3.

    6. Diaphragm Flexibility Rigid, Flexible and Semi-Rigid. All diaphragms are semi-rigid, meaning that load

    is distributed to from the diaphragm to the vertical elements depends on the stiffness of the diaphragm

    and stiffness of the vertical elements.

    1. Rigid When concrete is used, span-to-width is

  • Helpful Links for Determining Minimum Design Loads by Ryan Freund November 28, 2012 0 Comments

    Helpful Links for Determining Minimum Design Loads Hopefully these links can save you some time and help get you more accurate design loads. A quick heads-up

    you will usually need to search the town/county/state to see if the Authority Having Jurisdiction (AHJ) has a

    specific requirement.

    Wind Load

    A favorite for Wind Loads in accordance w/ ASCE 7

    http://www.atcouncil.org/windspeed/index.php

    Seismic

    A favorite for determining your base acceleration coefficients:

    http://earthquake.usgs.gov/hazards/designmaps/

    Snow

    This site is no longer free but when I used it, it was useful:

    http://www.groundsnowbyzip.com/

    This is a little dated and really not that useful but Ill mention it anyway:

    http://www.fs.fed.us/t-d/snow_load/states.htm

    Others

    This is a pay-for site but some may use it:

    http://www.groundsnowbyzip.com/

  • Wind Load ASCE 7-05 VS ASCE 7-10 by Ryan Freund April 27, 2012 2 Comments

    In comparing the 2010 edition to the 2005 edition of the ASCE 7 we see that there are significant changes to the

    layout, format, load factors used for wind and basic wind speed maps. These changes affect how you determine

    wind design wind pressures.

    References

    ASCE 7-10 Minimum Design Loads for Buildings and Other Structures. Found here

    ASCE 7-05 Minimum Design Loads for Buildings and Other Structures. Found here

    The Basics

    ASCE 7-05 uses a single basic wind speed map. For each building risk category an importance factor is applied.

    Note that these importance factors only depend on the type of building, not where the building is located. The

    wind-load factor is then applied to determine the design wind pressure. For this edition (05), the ASD wind-load

    factor is 1.0 and the strength design wind-load factor is 1.6.

    ASCE 7-10 uses three different basic wind speed maps for different categories of building occupancies. These

    maps provide basic wind speeds that are directly applicable for determining pressures for strength design.

    Consequently, the strength design wind-load factor was changed to 1.0 in this version. Simply put, ASCE 7-10

    uses three maps based on strength design in conjunction with a wind-load factor of 1.0 for strength design

    (LRFD) and 0.6 for service level loads (ASD), while ASCE 7-05 uses a single map with an importance factor and

    wind-load factor of 1.6 for strength design (LRFD) and 1.0 for service level loads (ASD).

    Why the Change?

    The commentary in ASCE 7-10 (section states 26.5.1) a few reasons for basic wind speed changes:

    1. A strength design wind speed map brings the design approach used for wind in-line with that used for

    seismic loads.

    2. Multiple maps remove the inconsistencies inherent the importance factor approach. With multiple maps

    a distinction may be made based on location (i.e. hurricane prone vs non-hurricane prone which also

    changes the recurrence interval).

    3. New maps establish a more uniform return period for the design-basis winds.

    4. The maps more clearly inform owners and their consultants (thats you) about the storm intensities for

    which designs are preformed.

    5. We have justify our pay check somehow

  • Summary:

    ASCE 7-10: 3 wind speed map based on 3-sec gust at 33ft above ground. The different maps are calibrated to

    strength level design (LRFD LF=1.0) and also include building classification and location.

    ASCE 7-05: (1) wind speed map based on 3-sec gust at 33ft above ground. Importance factors and Load

    Factors are used to increase design pressures.

    (Bonus Info)

    EIA-TIA-222 Rev G: Wind speeds are similar to 7-05 with different definitions of classification of structures and

    gust effect factors.

    EIA-TIA-222 Rev F: Wind speed maps based on fastest mile. These are not directly comparable to ASCE 7-05

    or 10, as the ASCE 7 uses 3-sec gust. The 3-sec gust represents the peak gust wind speed where as the

    fastest-mile wind speed represents the average wind speed over the time required for one mile of wind to pass

    the site. The design pressures are derived using different adjustments for height/exposure and gust effects than

    that of Rev G and/or the ASCE 7 standard

    How ASCE 7-10 Wind speed were developed return periods:

    Risk Cat I which is based on 25-yr return period equates to 300yr return period

    Risk Cat II: 700yrs or 0.0014 annual exceedance probability

    Risk Cat III and IV which are based on a 100-yr return period (thus there importance factor was greater in -05):

    1,700yrs or 0.000588 annual exceedance probability

    Note

    Interestingly enough new research gathered since 2005 indicated that design wind speeds should be reduced

    (they also note that the overall rate of intense storms increased). Therefore it is likely that you will noticed

    reduced wind pressures along coastal regions.

    For most of the US of A the wind load remains basically unchanged. A quick look at the basics

    ASCE 7-10 (eqn 27.3-1) or ASCE 7-05 (eqn 6-15) wind pressure:

    Assuming that and V = 90 mph then we have

    ASCE 7-05 => (ASD)

    ASCE 7-10 => (ASD)

    A nice paper by AWC (American Wood Council)

    http://www.awc.org/pdf/ASCE7-10WindChanges.pdf