wood group esp catalogue

359

Upload: hermit44535

Post on 19-Jan-2016

860 views

Category:

Documents


66 download

DESCRIPTION

ESP Catalogue

TRANSCRIPT

Page 1: Wood Group ESP Catalogue
Page 2: Wood Group ESP Catalogue
Page 3: Wood Group ESP Catalogue

WOOD GROUP ESP, INC. USA STANDARD TERMS AND CONDITIONS OF SALE

1. INTERPRETATION

In these Standard Terms and Conditions: “Buyer” means the person, firm or company with whom the Contract is made; “Buyer Group” means the Buyer, its co-venturers, its and their respective affiliates and agents and its and their respective directors, officers and employees; “Contract” means the contract between the Seller and the Buyer for the sale and purchase of the Products and/or Services, incorporating these Standard Terms and Conditions; “Order Acknowledgement” means the written acceptance by Seller of Buyer’s purchase order or specification which shall incorporate these Standard terms and Conditions which forms the Contract; “Product(s)” means any products or parts agreed in the Contract to be supplied to the Buyer by the Seller; “Seller” means the selling entity identified in the Order Acknowledgement, or if none, the quotation; “Seller Group” means the Seller, its sub-suppliers, its and their respective affiliates and agents, its and their respective directors, officers and employees; “Services” means any services agreed in the Contract to be supplied to the Buyer by the Seller; “Special Conditions” means those Special Terms and Conditions set out in the Order Acknowledgement or other document issued by the Seller.

2. APPLICABILITY

2.1 Subject to any variation under Section 2.3, the Contract shall be on these Standard Terms and Conditions to the exclusion of all other terms and conditions (including any terms and conditions which the Buyer purports to apply under any purchase order, confirmation of order, specification or other document).

2.2 No terms or conditions endorsed on, delivered with or contained in the Buyer’s purchase order, confirmation of order, specification or other documents shall form part of the Contract simply as a result of such document being referred to in the Contract.

2.3 These Standard Terms and Conditions apply to all the Seller’s sales and any variations to these Standard Terms and Conditions and any representations about the Products shall have no effect unless expressly agreed in writing and signed by an Authorized Signatory of the Seller. The Buyer acknowledges that it has not relied on any statement, promise or representation made or given by or on behalf of the Seller which is not set out in the Contract.

2.4 Each order or acceptance of a quotation for Products by the Buyer from the Seller shall be deemed to be an offer by the Buyer to buy Products subject to these Standard Terms and Conditions.

2.5 No order placed by the Buyer shall be deemed to be accepted by the Seller until an Order Acknowledgement is issued by the Seller, or (if earlier), the Seller delivers the Products or Services to the Buyer.

2.6 The Buyer shall ensure that the terms of its order and any applicable specification are complete and accurate. 2.7 Any quotation is given on the basis that no Contract shall come into existence until the Seller dispatches an Order Acknowledgement

or delivers the Products or Services to the Buyer. Any quotation is valid for a period of 30 days only from its date, provided that the Seller has not previously withdrawn it. All quotations of Seller are subject to change at any time.

3. PRICES All prices are subject to change without notice. Prices do not include packing and preparation of export shipment, inland or ocean freight, loading, unloading, carriage, insurance or forwarding fees, taxes, or duties of any kind or other similar charges applicable to the Products, Services and/or the Contract. Buyer agrees to pay such charges incurred by Seller on Buyer’s behalf together with additional handling charges upon receipt of Seller’s invoice for the same.

4. TERMS OF PAYMENT

Unless Seller and Buyer otherwise agree in writing to payment terms other than those specified herein, payment shall be made in U.S. dollars in accordance with remittance instructions furnished by Seller. (i) All payments shall be made within thirty (30) days after date of Seller’s invoice. (ii) Time for payment shall be of the essence. (iii) Seller may suspend credit to Buyer and may withhold shipment of Products ordered, suspend or cancel performance under

these Standard Terms and Conditions if in its sole judgment the financial condition of the Buyer warrants such action. Suspension of performance may result in rescheduling delays.

(iv) Prices do not include applicable taxes or duties. Buyer is solely responsible for paying all applicable taxes and duties. Seller will add taxes to the price where required by applicable law, and Buyer will pay all such taxes unless Buyer provides Seller with a duly executed tax exemption certificate in a form satisfactory to the Seller. If Buyer is required by applicable law to withhold any amount of tax from its payment to Seller, Buyer shall promptly pay such amount to the appropriate tax authority and take all reasonable steps to minimize such withholding tax. Buyer shall take all steps required to promptly obtain and deliver to Seller the appropriate certification of any such withholding in a form satisfactory to the Seller.

(v) The Buyer shall make all payments due under the Contract in full without any deduction whether by way of set-off, counterclaim, discount, abatement or otherwise.

(vi) All payments payable to the Seller under the Contract shall become due immediately on its termination despite any other provision.

Page 1 of 5

Page 4: Wood Group ESP Catalogue

(vii) If the Buyer fails to pay the Seller any sum due pursuant to the Contract, the Buyer shall be liable to pay interest to the Seller

on such sum from the due date for payment at the rate of eighteen percent (18%) per annum or at the highest rate allowed by law.

5. SHIPPING, DELIVERY, TITLE & RISK OF LOSS Products shall be delivered EXW (at location named by the Seller) (Incoterms 2000). Risk for loss or damage shall pass to Buyer upon Seller’s delivery to Buyer. Title shall pass to the Buyer upon receipt of payment in cleared funds by the Seller of amounts due in respect of the Contract. Seller may deliver the Products in installments. Each installment shall be a separate Contract and no cancellation or termination of any one Contract relating to an installment shall entitle the Buyer to repudiate or cancel any other Contract or installment. Delivery dates are intended to be an estimate and time and date for delivery shall not be made of the essence by notice or otherwise and are dependent on prompt receipt by Seller of all information and assistance required or requested by Seller to permit Seller to carry out its obligations under the Contract. Seller shall not be liable for any damage, losses or expenses incurred by Buyer if Seller fails to meet the estimated delivery dates. In the event that Products are not collected by Buyer on actual date of delivery, Seller may (at its sole discretion) place Products in storage at the sole cost, expense and risk of the Buyer.

6. FORCE MAJEURE

Seller reserves the right to defer the date of delivery of Products and/or the date of performance of Services, to cancel the Contract, or reduce the volume of the Products and/or amend the scope of the Services ordered by Buyer (without liability to Buyer) if it is prevented from or delayed in the carrying out of its business due to circumstances beyond its reasonable control, including but not limited to, natural disasters, forces of nature, earthquake, tidal wave, landslide, flood, lightening, hurricane, typhoon, storm or other weather condition not included in normal planning, epidemic and plague; changes in law or regulations, governmental actions; acts of civil or military authority; fire; explosion; lock-outs, strikes and/or labor disputes (whether or not relating to either party’s workforce); civil commotion; protests; war; national emergency; riot; civil insurrection; acts of terrorism; restraints or delays in transportation; restraints or delays in manufacturing and inability of Seller to obtain adequate or suitable supplies from usual sources, or acts of Buyer resulting in commercial impracticality. In the event of any such delay, the date of delivery and/or performance shall be deferred for a period equal to the time lost by reason of the delay.

7. WARRANTY

Seller warrants that Products manufactured by Seller, when properly stored, commissioned, installed, used and maintained, and Services performed by the Seller, shall be free from defects in material and workmanship. Seller’s obligation under this warranty shall be limited to replacing or repairing the part or parts or, the Products, at Seller’s option, which prove to be defective in material or workmanship within twelve (12) months from the date of installation or eighteen (18) months from the date of delivery, whichever shall occur first, or reperforming Services within twelve (12) months of the Services being supplied (“WARRANTY PERIOD ”), provided the Buyer gives Seller prompt notice of any defect and provides proof in a form and substance satisfactory to the Seller (acting in its sole discretion) including all relevant data and documentation needed to assess well and equipment performance and operations. Any defective part or parts must be returned freight prepaid by Buyer to an authorized service center designated by Seller for inspection. Seller will deliver any replacements for defective Products to Buyer prepaid to the delivery destination provided by the original order. Products returned to the Seller for which Seller provides replacement under this warranty shall become the property of the Seller.

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY, AND SELLER MAKES NO WARRANTY AS TO FITNESS FOR PURPOSE OR MERCHANTABILITY. SELLER’S WARRANTY OBLIGATIONS AND BUYER’S REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED HEREIN. THE WARRANTY PERIOD SHALL NOT BE EXTENDED FOR REPAIRED OR REPLACED PARTS OR PRODUCTS OR REPERFORMED SERVICES. SUCH PARTS OR PRODUCTS OR SERVICES SHALL REMAIN UNDER WARRANTY ONLY FOR THE UNEXPIRED PORTION OF THE WARRANTY PERIOD. SELLER’S SOLE LIABILITY SHALL BE AT ITS OPTION TO REPAIR OR REPLACE PARTS OR PRODUCTS OR REPERFORM SERVICES UNDER THIS CONDITION. SELLER MAY IN ITS SOLE DISCRETION CREDIT BUYER'S ACCOUNT FOR A PORTION OF SUCH PARTS OR PRODUCTS AND/OR SERVICES DETERMINED BY SELLER TO BE DEFECTIVE

The foregoing warranty does not apply to: (a) defect caused or contributed to by abrasive materials, corrosion due to aggressive fluids, lightening, improper voltage supply, mishandling or misapplication; (b) Products or parts which are normally consumed in operation, or have a normal life inherently shorter than the WARRANTY PERIOD; (c) alterations or repairs carried out without prior written approval of the Seller, or using equipment and accessories for a purpose other than that for which such equipment and accessories are intended; (d) installations carried out by the Buyer unless Buyer’s engineers have been appropriately trained and certified by Seller; (e) installations in which Buyer has not used the application engineering practices for the Products as approved by Supplier; (f) defective Products or Services where Buyer makes further use of the Products after the earlier of the Buyer’s awareness of the defect or the time when the Buyer ought to have become aware of such defect; (g) defects arising from or in connection with information, drawings, chart interpretations, technical specifications or instructions provided by the Buyer to the Seller.

Page 2 of 5

Page 5: Wood Group ESP Catalogue

8. LIMITATION OF LIABILITY

(i) FOR THE PURPOSE OF THIS SECTION 8(i), THE EXPRESSION "CONSEQUENTIAL LOSS" SHALL MEAN (IN EACH CASE WHETHER OR NOT FORESEEABLE AT THE DATE OF THE CONTRACT): (a) ANY AND ALL CONSEQUENTIAL, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE AND/OR SPECIAL LOSS AND/OR DAMAGE; AND (b) LOSS AND/OR DEFERRAL OF PRODUCTION, LOSS OF PRODUCT, LOSS OF GOODWILL, LOSS OF USE, LOSS OF REVENUE, PROFIT OR ANTICIPATED PROFIT, COST OF CAPITAL, IN EACH CASE WHETHER DIRECT OR INDIRECT TO THE EXTENT THAT SUCH LOSS, DEFERRAL AND/OR COST ARE NOT INCLUDED IN PARAGRAPH (a); AND (c) CLAIMS FOR SERVICE INTERRUPTION OR FAILURE TO SUPPLY, COSTS AND EXPENSES INCURRED IN CONNECTION WITH LABOR OVERHEAD, TRANSPORTATION OR SUBSTITUTE FACILITIES OR SUPPLY SOURCES, LABOR PERFORMED IN CONNECTION WITH THE REMOVAL AND REPLACEMENT OF PRODUCTS WITHIN THE WELL OR ANY OTHER LOSS OR DAMAGE INCURRED AS A RESULT OF OR OTHERWISE IN CONNECTION WITH INTERRUPTION OF SERVICE IN EACH CASE TO THE EXTENT THAT SUCH CLAIM IS NOT INCLUDED IN PARAGRAPH (i) OR PARAGRAPH (ii). NOTWITHSTANDING ANY PROVISION TO THE CONTRARY ELSEWHERE, IN NO CASE WILL THE SELLER BE LIABLE FOR CONSEQUENTIAL LOSS AND BUYER SHALL BE LIABLE FOR AND SHALL SAVE, INDEMNIFY, DEFEND AND HOLD HARMLESS THE SELLER GROUP FROM AND AGAINST ANY AND ALL CONSEQUENTIAL LOSS EVEN IF CAUSED BY THE SELLER'S SOLE, JOINT, COMPARATIVE, CONTRIBUTORY OR CONCURRENT NEGLIGENCE, FAULT, STRICT LIABILITY OR PRODUCT LIABILITY, AND REGARDLESS OF THE FORM OF ACTION, WHETHER CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF WARRANTY, INDEMNITY, STATUTE, STRICT LIABILITY OR OTHERWISE.

(ii) THE TOTAL LIABILITY OF SELLER ON ANY CLAIM WHETHER IN CONTRACT, TORT (INCLUDING

NEGLIGENCE WHETHER SOLE OR CONCURRENT) OR OTHERWISE ARISING OUT OF, CONNECTED WITH, OR RESULTING FROM THE MANUFACTURE, SALE, DELIVERY, RESALE, REPAIR, REPLACEMENT OR USE OF ANY PRODUCT, OR THE FURNISHING OF ANY SERVICE, OR THE PERFORMANCE OR NON-PERFORMANCE OF THE CONTRACT SHALL NOT EXCEED THE PRICE RECEIVED BY THE SELLER AND ALLOCABLE TO THE PRODUCT OR PART THEREOF, OR THE COST OF FURNISHING OF ANY SERVICE WORK WHICH GIVES RISE TO THE CLAIM.

(iii) BUYER UNDERSTANDS AND AGREES THAT THE FOREGOING LIABILITY LIMITATIONS ARE ESSENTIAL ELEMENTS OF THE CONTRACT AND THAT IN THE ABSENCE OF SUCH LIMITATIONS THE MATERIAL AND ECONOMIC TERMS OF THIS CONTRACT WOULD BE SUBSTANTIALLY DIFFERENT.

9. INDEMNITIES

All exclusions and indemnities given under this Section 9 (save for those under Sections 9.1(c) and 9.2(c)) and Section 8.1, shall apply irrespective of cause and notwithstanding the negligence or breach of duty (whether statutory or otherwise) of the indemnified party or any other entity or party and shall apply irrespective of any claim in tort, under contract or otherwise at law. For the purposes of Sections 9.1(c) and 9.2 (c), “third party” shall mean any party which is not a member of the Buyer Group nor the Seller Group. 9.1. The Seller shall be responsible for and shall save, indemnify, defend and hold harmless the Buyer Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of: (a) subject to Section 9.2(d), loss of or damage to property (other than the Products after delivery pursuant to Section 5)

of the Seller Group whether owned, hired, leased or otherwise provided by the Seller Group arising from or relating to the performance of the Contract;

(b) personal injury including death or disease to any person employed by the Seller Group arising from or relating to the performance of the Contract; and

(c) subject to Section 9.3, personal injury including death or disease or loss of or damage to the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether statutory or otherwise) of the Seller Group.

9.2 Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of: (a) loss of or damage to property of the Buyer Group, whether :-

(i) owned by the Buyer Group, or (ii) hired, leased or otherwise provided by or for the Buyer Group (including the Products after delivery pursuant to Section 5); and

(b) personal injury including death or disease to any person employed by the Buyer Group arising from relating to or in connection with the performance or non-performance of the Contract; (c) subject to any other express provisions of the Contract, personal injury including death or disease or loss of or damage to the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether statutory or otherwise) of the Buyer Group; and (d) at Seller’s option, either the repair or replacement or reimbursement of the full cost of Seller’s equipment, tools and/or instruments which are lost or damaged down-hole in the Buyer’s well during the provision of Services or are lost or

Page 3 of 5

Page 6: Wood Group ESP Catalogue

damaged due to abrasion or corrosion occasioned by well effluents unless such loss or damage is due to the sole negligence of the Seller.

9.3 Notwithstanding Section 9.1, Buyer shall be liable for, and shall defend, indemnify and hold Seller Group harmless from and against, any and all claims which arise out of the performance or non-performance of the Contract in relation to the following, and whether or not resulting from, or contributed to by, the negligence of Seller Group; (i) loss of or damage to any well or hole or any third party oil and gas production facilities; (ii) reservoir seepage or pollution originating underground or from the property of the Buyer or third party howsoever arising; (iii) blow-out, fire, explosion, cratering of any well or reservoir or any other uncontrolled well condition (including the costs to control a wild well and the removal of debris); (iv) damage to or escape of product, or substance from any facility including any pipeline or other subsurface facility. 9.4 Notwithstanding anything to the contrary in the Contract, Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of any acts or omissions of the employees or agents of the Seller Group in connection with the performance of the Services (or any part of the Services), where, in accordance with the Contract, the employees of the Seller Group are under the supervision, direction or control of the Buyer in respect of those Services or part of the Services.

10 NON-DELIVERY

The quantity of any consignment of Products as recorded by the Seller on dispatch from the Seller’s place of business or other designated location shall be conclusive evidence of the quantity received by Buyer on delivery unless Buyer can provide evidence proving the contrary. Seller shall not be liable for non-delivery of Products (even if caused by Seller’s negligence) unless Buyer gives written notice to the Seller of the non-delivery within forty eight (48) hours of the date and time when the Product would in the ordinary course of events have been received. Any liability of the Seller for non-delivery of the Products shall be limited to at Seller’s sole discretion either replacing the Products or issuing a credit note against any invoice raised for the Products.

11 PATENT INFRINGEMENT

If Buyer receives a claim or otherwise becomes aware that any Product or part thereof manufactured by Seller infringes or allegedly infringes a patent or other intellectual property right, Buyer shall notify Seller immediately in writing and give Seller information, assistance and exclusive authority to evaluate, defend and settle such claim or potential infringement. Seller shall then at its own expense and option (a) settle such claim, or (b) procure for Buyer the right to use such Product, or (c) replace or modify it to avoid infringement, or (d) remove it and refund the purchase price (including transportation and installation costs) less a reasonable amount for depreciation, or (e) defend against such claim.

12 CANCELLATION AND CHANGES The Buyer may not cancel or reschedule the delivery date of any Product and/or Services to be provided under the Contract without the prior written consent of the Seller. In the event that the Seller provides such consent, any such cancellation or rescheduling of Product and/or Services by Buyer will result in a charge to Buyer to be determined by the Seller. All specially designed or modified Products cancelled after commencement of manufacture will be subject to a cancellation charge which will include all costs and a reasonable margin for time employed, as determined by Seller. Cancellation charges for accessories and components sourced from third parties will be charged at full price. Seller shall, at its sole discretion, adjust the price or delivery dates or make such other amendments as may be required as a result of any change order agreed to be issued by the Buyer and Seller. No amendment to a purchase order or Order Acknowledgement or change order shall be valid unless agreed in writing by the Seller (at its sole discretion).

13 WAIVER

Any waiver by Seller of any breach or default by Buyer of any of the Buyer’s obligations under the Contract, or any failure by Seller to enforce any rights arising under the Contract shall not be construed as a waiver of any other or subsequent breach or default by Buyer or of Seller’s right to enforce its rights arising hereunder in any circumstances. In the event of any default by Buyer, Seller may decline to make further shipments. If Seller elects to continue to make deliveries, Seller’s action shall not constitute a waiver of any such default or affect Seller’s remedies for any such default.

14 ENTIRE AGREEMENT: The Order Acknowledgement, any Special Conditions and these Standard Terms and Conditions constitute the entire agreement between the parties relating to the sale of the Products and/or Services and supersedes all previous communications, representations, or agreements, either oral or written, with respect to the subject matter hereof. No prior representations or statements relating to the sale of the Products and/or Services made by any Seller representative, which are not stated herein, shall be binding on Seller.

15 EXPORT CONTROL

Buyer agrees that unless prior authorization is obtained from the U.S. Department of Commerce, neither Buyer nor its subsidiaries shall export, re-export, or release, directly or indirectly, any Product received from Seller to any destination or country to which the export, re-export or release of the technology or Product is prohibited by the Export Administration Regulations of the U.S. Department of Commerce ("EAR"), or prohibited by US or applicable non-US laws. Buyer will be responsible for obtaining any necessary export license or other documentation prior to the exportation or re-exportation of any Product acquired from Seller under the Contract. Further, Buyer shall give notice of the need to comply with such laws and regulations to any person, firm or entity which it has reason to believe is obtaining any such Product from Buyer with the intention of exportation. Each party shall secure, at its own expense, such licenses and export and import documents as are necessary for each respective party to fulfill its obligations under the Contract. If approvals cannot be obtained, Seller may terminate, cancel or otherwise

Page 4 of 5

Page 7: Wood Group ESP Catalogue

be excused from performing any obligations it may have under the Contract. Any export classification made by Seller shall be for Seller's internal use only and shall not be construed as a representation or warranty regarding the proper export classification for such Product or whether an export license or other documentation is required for the exportation of such Product. This Section 15 shall survive termination of the Contract.

16 BUSINESS ETHICS

Neither Seller nor Buyer shall make any payment or take any action that could be construed to be the payment of money or other thing of value to any government official, political party, or political party candidate for the purpose of influencing any act or inducing any government official to use his or its influence to assist in obtaining or retaining business in any country in a manner which is illegal or which would subject the Seller to civil or criminal penalties, or which is inconsistent with Seller’s Business Ethics Policy.

17 ASSIGNMENT

The Seller may assign this Contract or any part of it to any person, firm or company. The Buyer shall not be entitled to assign the Contract or any part of it without the prior written consent of the Seller.

18 ARBITRATION

The parties agree that any and all disputes or controversies that may arise between the parties arising out of or related to this Contract shall be determined by binding arbitration. Any such arbitration shall be determined before the American Arbitration Association (“AAA”) in accordance with AAA rules then in effect, with each party nominating one arbiter and the two arbiters nominating a third, and that any arbitration proceedings shall be held in Oklahoma City, Oklahoma. Judgment upon arbitration awards may be entered in any court, state or federal, having jurisdiction.

19 GOVERNING LAW

This Contract shall be governed and construed in accordance with the laws of the State of Oklahoma, without giving effect to any

conflicts of laws principles.

20 MISCELLANEOUS All samples, drawings, descriptive matter, specifications and advertising issued by the Seller and any descriptions or illustrations contained in the Seller’s catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the Products and/or Services described in them. They shall not form part of the Contract.

The Buyer shall at its own expense secure any permits or any other authorizations (including but not limited to work permits and visas for employees of the Seller) which may be required to permit the Seller to perform the Services. The Buyer agrees to indemnify the Seller against any costs, claims, actions, demands or expenses incurred or suffered in connection with the Buyer’s failure to obtain any permits or authorizations required to perform the Services. If any provision of the Contract is found by any court, tribunal or administrative body of competent jurisdiction to be wholly or partly illegal, invalid, void, voidable, unenforceable or unreasonable it shall to the extent of such illegality, invalidity, voidness, voidability, unenforceability or unreasonableness be deemed severable and the remaining provisions of the Contract and the remainder of such provision shall continue in full force.

These Standard Terms and Conditions are subject to change without prior written notice at any time and from time to time at the Seller’s sole discretion. All communications between the parties about the Contract shall be in writing and delivered by hand or sent by fax to its registered office or such other address as shall be notified to the other party. Communications shall be deemed to have been received if delivered by hand, on the day of delivery or if sent by fax on a business day at the time of transmission and otherwise on the next working day.

Page 5 of 5

Page 8: Wood Group ESP Catalogue

WOOD GROUP ESP (CANADA) LTD. STANDARD TERMS AND CONDITIONS OF SALE

1. INTERPRETATION

In these Standard Terms and Conditions: “Buyer” means the person, firm or company with whom the Contract is made; “Buyer Group” means the Buyer, its co-venturers, its and their respective affiliates and agents and its and their respective directors, officers and employees; “Contract” means the contract between the Seller and the Buyer for the sale and purchase of the Products and/or Services, incorporating these Standard Terms and Conditions; “Order Acknowledgement” means the written acceptance by Seller of Buyer’s purchase order or specification which shall incorporate these Standard terms and Conditions which forms the Contract; “Product(s)” means any products or parts agreed in the Contract to be supplied to the Buyer by the Seller; “Seller” means the selling entity identified in the Order Acknowledgement, or if none, the quotation; “Seller Group” means the Seller, its sub-suppliers, its and their respective affiliates and agents, its and their respective directors, officers and employees; “Services” means any services agreed in the Contract to be supplied to the Buyer by the Seller; “Special Conditions” means those Special Terms and Conditions set out in the Order Acknowledgement or other document issued by the Seller.

2. APPLICABILITY

2.1 Subject to any variation under Section 2.3, the Contract shall be on these Standard Terms and Conditions to the exclusion of all other terms and conditions (including any terms and conditions which the Buyer purports to apply under any purchase order, confirmation of order, specification or other document).

2.2 No terms or conditions endorsed on, delivered with or contained in the Buyer’s purchase order, confirmation of order, specification or other documents shall form part of the Contract simply as a result of such document being referred to in the Contract.

2.3 These Standard Terms and Conditions apply to all the Seller’s sales and any variations to these Standard Terms and Conditions and any representations about the Products shall have no effect unless expressly agreed in writing and signed by an Authorized Signatory of the Seller. The Buyer acknowledges that it has not relied on any statement, promise or representation made or given by or on behalf of the Seller which is not set out in the Contract.

2.4 Each order or acceptance of a quotation for Products by the Buyer from the Seller shall be deemed to be an offer by the Buyer to buy Products subject to these Standard Terms and Conditions.

2.5 No order placed by the Buyer shall be deemed to be accepted by the Seller until an Order Acknowledgement is issued by the Seller, or (if earlier), the Seller delivers the Products or Services to the Buyer.

2.6 The Buyer shall ensure that the terms of its order and any applicable specification are complete and accurate. 2.7 Any quotation is given on the basis that no Contract shall come into existence until the Seller dispatches an Order Acknowledgement

or delivers the Products or Services to the Buyer. Any quotation is valid for a period of 30 days only from its date, provided that the Seller has not previously withdrawn it. All quotations of Seller are subject to change at any time.

3. PRICES

All prices are subject to change without notice. Prices do not include packing and preparation of export shipment, inland or ocean freight, loading, unloading, carriage, insurance or forwarding fees, taxes, or duties of any kind or other similar charges applicable to the Products, Services and/or the Contract. Buyer agrees to pay such charges incurred by Seller on Buyer’s behalf together with additional handling charges upon receipt of Seller’s invoice for the same.

4. TERMS OF PAYMENT

Unless Seller and Buyer otherwise agree in writing to payment terms other than those specified herein, payment shall be made in U.S. dollars in accordance with remittance instructions furnished by Seller. (i) All payments shall be made within thirty (30) days after date of Seller’s invoice. (ii) Time for payment shall be of the essence. (iii) Seller may suspend credit to Buyer and may withhold shipment of Products ordered, suspend or cancel performance under

these Standard Terms and Conditions if in its sole judgment the financial condition of the Buyer warrants such action. Suspension of performance may result in rescheduling delays.

(iv) Prices do not include applicable taxes or duties. Buyer is solely responsible for paying all applicable taxes and duties. Seller will add taxes to the price where required by applicable law, and Buyer will pay all such taxes unless Buyer provides Seller with a duly executed tax exemption certificate in a form satisfactory to the Seller. If Buyer is required by applicable law to withhold any amount of tax from its payment to Seller, Buyer shall promptly pay such amount to the appropriate tax authority and take all reasonable steps to minimize such withholding tax. Buyer shall take all steps required to promptly obtain and deliver to Seller the appropriate certification of any such withholding in a form satisfactory to the Seller.

(v) The Buyer shall make all payments due under the Contract in full without any deduction whether by way of set-off, counterclaim, discount, abatement or otherwise.

(vi) All payments payable to the Seller under the Contract shall become due immediately on its termination despite any other provision.

Page 1 of 5

Page 9: Wood Group ESP Catalogue

(vii) If the Buyer fails to pay the Seller any sum due pursuant to the Contract, the Buyer shall be liable to pay interest to the Seller

on such sum from the due date for payment at the rate of eighteen percent (18%) per annum or at the highest rate allowed by law.

5. SHIPPING, DELIVERY, TITLE & RISK OF LOSS Products shall be delivered EXW (at location named by the Seller) (Incoterms 2000). Risk for loss or damage shall pass to Buyer upon Seller’s delivery to Buyer. Title shall pass to the Buyer upon receipt of payment in cleared funds by the Seller of amounts due in respect of the Contract. Seller may deliver the Products in installments. Each installment shall be a separate Contract and no cancellation or termination of any one Contract relating to an installment shall entitle the Buyer to repudiate or cancel any other Contract or installment. Delivery dates are intended to be an estimate and time and date for delivery shall not be made of the essence by notice or otherwise and are dependent on prompt receipt by Seller of all information and assistance required or requested by Seller to permit Seller to carry out its obligations under the Contract. Seller shall not be liable for any damage, losses or expenses incurred by Buyer if Seller fails to meet the estimated delivery dates. In the event that Products are not collected by Buyer on actual date of delivery, Seller may (at its sole discretion) place Products in storage at the sole cost, expense and risk of the Buyer.

6. FORCE MAJEURE

Seller reserves the right to defer the date of delivery of Products and/or the date of performance of Services, to cancel the Contract, or reduce the volume of the Products and/or amend the scope of the Services ordered by Buyer (without liability to Buyer) if it is prevented from or delayed in the carrying out of its business due to circumstances beyond its reasonable control, including but not limited to, natural disasters, forces of nature, earthquake, tidal wave, landslide, flood, lightening, hurricane, typhoon, storm or other weather condition not included in normal planning, epidemic and plague; changes in law or regulations, governmental actions; acts of civil or military authority; fire; explosion; lock-outs, strikes and/or labor disputes (whether or not relating to either party’s workforce); civil commotion; protests; war; national emergency; riot; civil insurrection; acts of terrorism; restraints or delays in transportation; restraints or delays in manufacturing and inability of Seller to obtain adequate or suitable supplies from usual sources, or acts of Buyer resulting in commercial impracticality. In the event of any such delay, the date of delivery and/or performance shall be deferred for a period equal to the time lost by reason of the delay.

7. WARRANTY

Seller warrants that Products manufactured by Seller, when properly stored, commissioned, installed, used and maintained, and Services performed by the Seller, shall be free from defects in material and workmanship. Seller’s obligation under this warranty shall be limited to replacing or repairing the part or parts or, the Products, at Seller’s option, which prove to be defective in material or workmanship within twelve (12) months from the date of installation or eighteen (18) months from the date of delivery, whichever shall occur first, or reperforming Services within twelve (12) months of the Services being supplied (“WARRANTY PERIOD ”), provided the Buyer gives Seller prompt notice of any defect and provides proof in a form and substance satisfactory to the Seller (acting in its sole discretion) including all relevant data and documentation needed to assess well and equipment performance and operations. Any defective part or parts must be returned freight prepaid by Buyer to an authorized service center designated by Seller for inspection. Seller will deliver any replacements for defective Products to Buyer prepaid to the delivery destination provided by the original order. Products returned to the Seller for which Seller provides replacement under this warranty shall become the property of the Seller.

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY, AND SELLER MAKES NO WARRANTY AS TO FITNESS FOR PURPOSE OR MERCHANTABILITY. SELLER’S WARRANTY OBLIGATIONS AND BUYER’S REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED HEREIN. THE WARRANTY PERIOD SHALL NOT BE EXTENDED FOR REPAIRED OR REPLACED PARTS OR PRODUCTS OR REPERFORMED SERVICES. SUCH PARTS OR PRODUCTS OR SERVICES SHALL REMAIN UNDER WARRANTY ONLY FOR THE UNEXPIRED PORTION OF THE WARRANTY PERIOD. SELLER’S SOLE LIABILITY SHALL BE AT ITS OPTION TO REPAIR OR REPLACE PARTS OR PRODUCTS OR REPERFORM SERVICES UNDER THIS CONDITION. SELLER MAY IN ITS SOLE DISCRETION CREDIT BUYER'S ACCOUNT FOR A PORTION OF SUCH PARTS OR PRODUCTS AND/OR SERVICES DETERMINED BY SELLER TO BE DEFECTIVE

The foregoing warranty does not apply to: (a) defect caused or contributed to by abrasive materials, corrosion due to aggressive fluids, lightening, improper voltage supply, mishandling or misapplication; (b) Products or parts which are normally consumed in operation, or have a normal life inherently shorter than the WARRANTY PERIOD; (c) alterations or repairs carried out without prior written approval of the Seller, or using equipment and accessories for a purpose other than that for which such equipment and accessories are intended; (d) installations carried out by the Buyer unless Buyer’s engineers have been appropriately trained and certified by Seller; (e) installations in which Buyer has not used the application engineering practices for the Products as approved by Supplier; (f) defective Products or Services where Buyer makes further use of the Products after the earlier of the Buyer’s awareness of the defect or the time when the Buyer ought to have become aware of such defect; (g) defects arising from or in connection with information, drawings, chart interpretations, technical specifications or instructions provided by the Buyer to the Seller.

Page 2 of 5

Page 10: Wood Group ESP Catalogue

8. LIMITATION OF LIABILITY

(i) FOR THE PURPOSE OF THIS SECTION 8(i), THE EXPRESSION "CONSEQUENTIAL LOSS" SHALL MEAN (IN EACH CASE WHETHER OR NOT FORESEEABLE AT THE DATE OF THE CONTRACT): (a) ANY AND ALL CONSEQUENTIAL, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE AND/OR SPECIAL LOSS AND/OR DAMAGE; AND (b) LOSS AND/OR DEFERRAL OF PRODUCTION, LOSS OF PRODUCT, LOSS OF GOODWILL, LOSS OF USE, LOSS OF REVENUE, PROFIT OR ANTICIPATED PROFIT, COST OF CAPITAL, IN EACH CASE WHETHER DIRECT OR INDIRECT TO THE EXTENT THAT SUCH LOSS, DEFERRAL AND/OR COST ARE NOT INCLUDED IN PARAGRAPH (a); AND (c) CLAIMS FOR SERVICE INTERRUPTION OR FAILURE TO SUPPLY, COSTS AND EXPENSES INCURRED IN CONNECTION WITH LABOR OVERHEAD, TRANSPORTATION OR SUBSTITUTE FACILITIES OR SUPPLY SOURCES, LABOR PERFORMED IN CONNECTION WITH THE REMOVAL AND REPLACEMENT OF PRODUCTS WITHIN THE WELL OR ANY OTHER LOSS OR DAMAGE INCURRED AS A RESULT OF OR OTHERWISE IN CONNECTION WITH INTERRUPTION OF SERVICE IN EACH CASE TO THE EXTENT THAT SUCH CLAIM IS NOT INCLUDED IN PARAGRAPH (i) OR PARAGRAPH (ii). NOTWITHSTANDING ANY PROVISION TO THE CONTRARY ELSEWHERE, IN NO CASE WILL THE SELLER BE LIABLE FOR CONSEQUENTIAL LOSS AND BUYER SHALL BE LIABLE FOR AND SHALL SAVE, INDEMNIFY, DEFEND AND HOLD HARMLESS THE SELLER GROUP FROM AND AGAINST ANY AND ALL CONSEQUENTIAL LOSS EVEN IF CAUSED BY THE SELLER'S SOLE, JOINT, COMPARATIVE, CONTRIBUTORY OR CONCURRENT NEGLIGENCE, FAULT, STRICT LIABILITY OR PRODUCT LIABILITY, AND REGARDLESS OF THE FORM OF ACTION, WHETHER CONTRACT, TORT (INCLUDING NEGLIGENCE), BREACH OF WARRANTY, INDEMNITY, STATUTE, STRICT LIABILITY OR OTHERWISE.

(ii) THE TOTAL LIABILITY OF SELLER ON ANY CLAIM WHETHER IN CONTRACT, TORT (INCLUDING

NEGLIGENCE WHETHER SOLE OR CONCURRENT) OR OTHERWISE ARISING OUT OF, CONNECTED WITH, OR RESULTING FROM THE MANUFACTURE, SALE, DELIVERY, RESALE, REPAIR, REPLACEMENT OR USE OF ANY PRODUCT, OR THE FURNISHING OF ANY SERVICE, OR THE PERFORMANCE OR NON-PERFORMANCE OF THE CONTRACT SHALL NOT EXCEED THE PRICE RECEIVED BY THE SELLER AND ALLOCABLE TO THE PRODUCT OR PART THEREOF, OR THE COST OF FURNISHING OF ANY SERVICE WORK WHICH GIVES RISE TO THE CLAIM.

(iii) BUYER UNDERSTANDS AND AGREES THAT THE FOREGOING LIABILITY LIMITATIONS ARE ESSENTIAL ELEMENTS OF THE CONTRACT AND THAT IN THE ABSENCE OF SUCH LIMITATIONS THE MATERIAL AND ECONOMIC TERMS OF THIS CONTRACT WOULD BE SUBSTANTIALLY DIFFERENT.

9. INDEMNITIES

All exclusions and indemnities given under this Section 9 (save for those under Sections 9.1(c) and 9.2(c)) and Section 8.1, shall apply irrespective of cause and notwithstanding the negligence or breach of duty (whether statutory or otherwise) of the indemnified party or any other entity or party and shall apply irrespective of any claim in tort, under contract or otherwise at law. For the purposes of Sections 9.1(c) and 9.2 (c), “third party” shall mean any party which is not a member of the Buyer Group nor the Seller Group. 9.1. The Seller shall be responsible for and shall save, indemnify, defend and hold harmless the Buyer Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of: (a) subject to Section 9.2(d), loss of or damage to property (other than the Products after delivery pursuant to Section 5)

of the Seller Group whether owned, hired, leased or otherwise provided by the Seller Group arising from or relating to the performance of the Contract;

(b) personal injury including death or disease to any person employed by the Seller Group arising from or relating to the performance of the Contract; and

(c) subject to Section 9.3, personal injury including death or disease or loss of or damage to the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether statutory or otherwise) of the Seller Group.

9.2 Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of: (a) loss of or damage to property of the Buyer Group, whether :-

(i) owned by the Buyer Group, or (ii) hired, leased or otherwise provided by or for the Buyer Group (including the Products after delivery pursuant to Section 5); and

(b) personal injury including death or disease to any person employed by the Buyer Group arising from relating to or in connection with the performance or non-performance of the Contract; (c) subject to any other express provisions of the Contract, personal injury including death or disease or loss of or damage to the property of any third party to the extent that any such injury, loss or damage is caused by the negligence or breach of duty (whether statutory or otherwise) of the Buyer Group; and (d) at Seller’s option, either the repair or replacement or reimbursement of the full cost of Seller’s equipment, tools and/or instruments which are lost or damaged down-hole in the Buyer’s well during the provision of Services or are lost or

Page 3 of 5

Page 11: Wood Group ESP Catalogue

damaged due to abrasion or corrosion occasioned by well effluents unless such loss or damage is due to the sole negligence of the Seller.

9.3 Notwithstanding Section 9.1, Buyer shall be liable for, and shall defend, indemnify and hold Seller Group harmless from and against, any and all claims which arise out of the performance or non-performance of the Contract in relation to the following, and whether or not resulting from, or contributed to by, the negligence of Seller Group; (i) loss of or damage to any well or hole or any third party oil and gas production facilities; (ii) reservoir seepage or pollution originating underground or from the property of the Buyer or third party howsoever arising; (iii) blow-out, fire, explosion, cratering of any well or reservoir or any other uncontrolled well condition (including the costs to control a wild well and the removal of debris); (iv) damage to or escape of product, or substance from any facility including any pipeline or other subsurface facility. 9.4 Notwithstanding anything to the contrary in the Contract, Buyer shall be responsible for and shall save, indemnify, defend and hold harmless Seller Group from and against all claims, losses, damages, costs (including legal costs) expenses and liabilities in respect of any acts or omissions of the employees or agents of the Seller Group in connection with the performance of the Services (or any part of the Services), where, in accordance with the Contract, the employees of the Seller Group are under the supervision, direction or control of the Buyer in respect of those Services or part of the Services.

10 NON-DELIVERY

The quantity of any consignment of Products as recorded by the Seller on dispatch from the Seller’s place of business or other designated location shall be conclusive evidence of the quantity received by Buyer on delivery unless Buyer can provide evidence proving the contrary. Seller shall not be liable for non-delivery of Products (even if caused by Seller’s negligence) unless Buyer gives written notice to the Seller of the non-delivery within forty eight (48) hours of the date and time when the Product would in the ordinary course of events have been received. Any liability of the Seller for non-delivery of the Products shall be limited to at Seller’s sole discretion either replacing the Products or issuing a credit note against any invoice raised for the Products.

11 PATENT INFRINGEMENT

If Buyer receives a claim or otherwise becomes aware that any Product or part thereof manufactured by Seller infringes or allegedly infringes a patent or other intellectual property right, Buyer shall notify Seller immediately in writing and give Seller information, assistance and exclusive authority to evaluate, defend and settle such claim or potential infringement. Seller shall then at its own expense and option (a) settle such claim, or (b) procure for Buyer the right to use such Product, or (c) replace or modify it to avoid infringement, or (d) remove it and refund the purchase price (including transportation and installation costs) less a reasonable amount for depreciation, or (e) defend against such claim.

12 CANCELLATION AND CHANGES The Buyer may not cancel or reschedule the delivery date of any Product and/or Services to be provided under the Contract without the prior written consent of the Seller. In the event that the Seller provides such consent, any such cancellation or rescheduling of Product and/or Services by Buyer will result in a charge to Buyer to be determined by the Seller. All specially designed or modified Products cancelled after commencement of manufacture will be subject to a cancellation charge which will include all costs and a reasonable margin for time employed, as determined by Seller. Cancellation charges for accessories and components sourced from third parties will be charged at full price. Seller shall, at its sole discretion, adjust the price or delivery dates or make such other amendments as may be required as a result of any change order agreed to be issued by the Buyer and Seller. No amendment to a purchase order or Order Acknowledgement or change order shall be valid unless agreed in writing by the Seller (at its sole discretion).

13 WAIVER

Any waiver by Seller of any breach or default by Buyer of any of the Buyer’s obligations under the Contract, or any failure by Seller to enforce any rights arising under the Contract shall not be construed as a waiver of any other or subsequent breach or default by Buyer or of Seller’s right to enforce its rights arising hereunder in any circumstances. In the event of any default by Buyer, Seller may decline to make further shipments. If Seller elects to continue to make deliveries, Seller’s action shall not constitute a waiver of any such default or affect Seller’s remedies for any such default.

14 ENTIRE AGREEMENT: The Order Acknowledgement, any Special Conditions and these Standard Terms and Conditions constitute the entire agreement between the parties relating to the sale of the Products and/or Services and supersedes all previous communications, representations, or agreements, either oral or written, with respect to the subject matter hereof. No prior representations or statements relating to the sale of the Products and/or Services made by any Seller representative, which are not stated herein, shall be binding on Seller.

15 EXPORT CONTROL

Buyer agrees that unless prior authorization is obtained from the U.S. Department of Commerce, neither Buyer nor its subsidiaries shall export, re-export, or release, directly or indirectly, any Product received from Seller to any destination or country to which the export, re-export or release of the technology or Product is prohibited by the Export Administration Regulations of the U.S. Department of Commerce ("EAR"), or prohibited by US or applicable non-US laws. Buyer will be responsible for obtaining any necessary export license or other documentation prior to the exportation or re-exportation of any Product acquired from Seller under the Contract. Further, Buyer shall give notice of the need to comply with such laws and regulations to any person, firm or entity which it has reason to believe is obtaining any such Product from Buyer with the intention of exportation. Each party shall secure, at its own expense, such licenses and export and import documents as are necessary for each respective party to fulfill its obligations under the Contract. If approvals cannot be obtained, Seller may terminate, cancel or otherwise

Page 4 of 5

Page 12: Wood Group ESP Catalogue

be excused from performing any obligations it may have under the Contract. Any export classification made by Seller shall be for Seller's internal use only and shall not be construed as a representation or warranty regarding the proper export classification for such Product or whether an export license or other documentation is required for the exportation of such Product. This Section 15 shall survive termination of the Contract.

16 BUSINESS ETHICS

Neither Seller nor Buyer shall make any payment or take any action that could be construed to be the payment of money or other thing of value to any government official, political party, or political party candidate for the purpose of influencing any act or inducing any government official to use his or its influence to assist in obtaining or retaining business in any country in a manner which is illegal or which would subject the Seller to civil or criminal penalties, or which is inconsistent with Seller’s Business Ethics Policy.

17 ASSIGNMENT

The Seller may assign this Contract or any part of it to any person, firm or company. The Buyer shall not be entitled to assign the Contract or any part of it without the prior written consent of the Seller.

18 ARBITRATION

The parties agree that any and all disputes or controversies that may arise between the parties arising out of or related to this Contract shall be determined by binding arbitration. Any such arbitration shall be determined before the American Arbitration Association (“AAA”) in accordance with AAA rules then in effect, with each party nominating one arbiter and the two arbiters nominating a third, and that any arbitration proceedings shall be held in Oklahoma City, Oklahoma, USA. Judgment upon arbitration awards may be entered in any court, state or federal, having jurisdiction.

19 GOVERNING LAW

This Contract shall be governed and construed in accordance with the laws of the State of Oklahoma, USA, without giving effect to

any conflicts of laws principles.

20 MISCELLANEOUS All samples, drawings, descriptive matter, specifications and advertising issued by the Seller and any descriptions or illustrations contained in the Seller’s catalogues or brochures are issued or published for the sole purpose of giving an approximate idea of the Products and/or Services described in them. They shall not form part of the Contract.

The Buyer shall at its own expense secure any permits or any other authorizations (including but not limited to work permits and visas for employees of the Seller) which may be required to permit the Seller to perform the Services. The Buyer agrees to indemnify the Seller against any costs, claims, actions, demands or expenses incurred or suffered in connection with the Buyer’s failure to obtain any permits or authorizations required to perform the Services. If any provision of the Contract is found by any court, tribunal or administrative body of competent jurisdiction to be wholly or partly illegal, invalid, void, voidable, unenforceable or unreasonable it shall to the extent of such illegality, invalidity, voidness, voidability, unenforceability or unreasonableness be deemed severable and the remaining provisions of the Contract and the remainder of such provision shall continue in full force.

These Standard Terms and Conditions are subject to change without prior written notice at any time and from time to time at the Seller’s sole discretion. All communications between the parties about the Contract shall be in writing and delivered by hand or sent by fax to its registered office or such other address as shall be notified to the other party. Communications shall be deemed to have been received if delivered by hand, on the day of delivery or if sent by fax on a business day at the time of transmission and otherwise on the next working day.

Page 5 of 5

Page 13: Wood Group ESP Catalogue

WOOD GROUP ESP TÉRMINOS Y CONDICIONES DE VENTA ESTÁNDAR

1. INTERPRETACIÓN En estos Términos y Condiciones de Venta Estándar: “Comprador” significa la persona, firma o empresa con quien se celebra el Contrato; “Grupo del Comprador” significa el Comprador, sus accionistas, sus empresas asociadas, sus afiliadas y agentes y sus respectivos directores, empleados de alto rango y empleados en general; “Contrato” significa el contrato celebrado entre el Vendedor y el Comprador para la venta y compra de los Productos y/o Servicios, incorporando estos Términos y Condiciones Estándar; “Acuse de Recibo de la Orden” significa la aceptación por escrito por parte del Vendedor de la orden de compra o especificaciones del Comprador que incorporarán estos Términos y Condiciones Estándar que constituyen el Contrato; “Producto(s)” significa los productos o partes cuyo suministro por el Vendedor al Comprador se acuerda en el Contrato; “Vendedor” significa la entidad vendedora identificada en el Acuse de Recibo de la Orden, o de no haber uno, en la cotización; “Grupo del Vendedor” significa el Vendedor, sus accionistas, sus sub-proveedores, y sus respectivas afiliadas y agentes y sus respectivos directores, altos empleados y empleados en general; “Servicios” significa los servicios cuyo suministro por el Vendedor al Comprador se acuerda en el Contrato; “Condiciones especiales” significa los Términos y Condiciones Especiales establecidos en el Acuse de Recibo de la Orden u otro documento expedido por el Vendedor.

2. APLICABILIDAD

2.1. Sujeto a cualquier variación bajo la condición 2.3, el Contrato consistirá de estos Términos y Condiciones Estándar con exclusión de cualquier otros términos y condiciones (incluyendo los términos y condiciones que el Comprador tenga por intención aplicar bajo cualquier orden de compra, confirmación de la orden, especificaciones u otro documento).

2.2. Los términos y condiciones aprobados, entregados o contenidos, respectivamente, en la orden de compra del Comprador, confirmación de la orden, especificaciones u otros documentos no formarán parte del Contrato simplemente por el hecho de que dichos documentos sean referidos en el Contrato. 2.3. Estos Términos y Condiciones Estándar se aplicarán a todas las ventas del Vendedor y los cambios de dichos Términos y Condiciones Estándar y las representaciones hechas acerca de los Productos no tendrán ningún efecto, salvo que sean acordados en forma expresa por escrito y lleven la firma de un Signatario autorizado por el Vendedor. El Comprador reconoce que no ha actuado en base a declaración, promesa o representación alguna hecha o manifestada por el Vendedor, o en nombre del Vendedor, que no figure en el Contrato. 2.4. Cada orden o aceptación de una cotización de Productos del Vendedor por parte del Comprador se considerará como una oferta del Comprador para la compra de Productos, sujeta a estos Términos y Condiciones Estándar. 2.5. Ninguna orden colocada por el Comprador se considerará aceptada por el Vendedor hasta que se expida el Acuse de Recibo de la Orden por el Vendedor, o, hasta que el Vendedor entregue los Productos o suministre los Servicios al Comprador, lo que ocurra primero. 2.6. El Comprador se asegurará de que los términos de su orden y las especificaciones aplicables se formulen en forma completa y precisa. 2.7. La cotización se hace sobre la base de que el Contrato no entrará en vigencia hasta que el Vendedor expida el Acuse de Recibo de la Orden o entregue los Productos o suministre los Servicios al Comprador. La cotización es válida por un período de 30 días contados desde la fecha de la misma, siempre que el Vendedor no la haya retirado anteriormente. Todas las cotizaciones del Vendedor están sujetas a cambio en cualquier momento. 3. PRECIOS

Página 1 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 14: Wood Group ESP Catalogue

Todos los precios están sujetos a cambio sin aviso. Los precios no incluyen el empaque y preparación del embarque de exportación, flete terrestre o marítimo, carga, descarga, transporte, seguro o comisión del agente de expedición de la mercadería, impuestos o derechos de aduana de cualquier clase u otros cobros similares aplicables a los Productos, Servicios y/o el Contrato. El Comprador acuerda pagar los costos incurridos por el Vendedor en nombre del Comprador, junto con los gastos de manipulación adicionales una vez que reciba la factura del Vendedor por los mismos.

4. TÉRMINOS DE PAGO

Salvo que el Vendedor y el Comprador acuerden por escrito términos de pago distintos a los estipulados en el presente el pago se hará en dólares estadounidenses, conforme con las instrucciones de remesa proporcionadas por el Vendedor. (i) El pago se hará mediante carta de crédito a ser abierta por el Comprador, a su costo,

incluyendo los gastos de confirmación. Todas las cartas de crédito serán en favor del Vendedor, y en una forma que sea aceptable para el Vendedor, deberán ser por las cantidades que sean suficientes y por los períodos que sean necesarios para cumplir con todas las obligaciones de pago, serán irrevocables y se emitirán o confirmarán por un banco que sea satisfactorio para el Vendedor, dentro de los 30 días de la expedición del Acuse de Recibo de la Orden.

(ii) Todos los pagos se harán dentro de los treinta (30) días siguientes a la fecha de la factura del Vendedor.

(iii) El plazo para el pago es de la esencia del contrato. (iv) El Vendedor puede suspender el crédito al Comprador y puede retener el embarque de los

Productos ordenados, suspender o cancelar su propio cumplimiento bajo estos Términos y Condiciones Estándar si, a su juicio exclusivo, la condición financiera del Comprador justifica dicha acción. La suspensión de su propio cumplimiento puede resultar en la reprogramación de los plazos por las demoras.

(v) Los precios no incluyen los impuestos o derechos de aduana aplicables. El Comprador es el único responsable del pago de todos los impuestos y derechos de aduana aplicables. El Vendedor agregará impuestos al precio cuando así lo requiera la ley aplicable, y el Comprador pagará dichos impuestos en su totalidad, salvo que el Comprador le presente al Vendedor un certificado de exención tributaria debidamente otorgado, en una forma que sea satisfactoria para el Vendedor. Si bajo la ley aplicable se exige que el Comprador retenga los impuestos correspondientes al pago hecho al Vendedor, el Comprador remitirá en forma inmediata a la autoridad fiscal correspondiente el monto de dicha retención de impuestos y adoptará todas las medidas que sean razonables para minimizar dicha retención de impuestos. El Comprador adoptará todas las medidas requeridas para obtener y entregar en forma inmediata al Vendedor la certificación, correspondiente a dicha retención en una forma que sea satisfactoria para el Vendedor.

(vi) El Comprador abonará todos los pagos vencidos bajo el Contrato en forma total sin ninguna deducción, ya sea ésta en la forma de un mecanismo de compensación, reconvención, descuento, rebaja o de otro modo.

(vii) Todos los pagos pagaderos al Vendedor bajo el Contrato vencerán en forma inmediata a la terminación del Contrato salvo cualquier estipulación en contrario.

(viii) Si el Comprador no cumple con pagar al Vendedor una suma vencida según el Contrato, el Comprador será responsable del pago de intereses al Vendedor que se devenguen sobre dicha suma desde la fecha de pago, a razón de una tasa de interés anual de 3% por encima del tipo de interés bancario del mercado de Londres (LIBOR) del Dólar Estadounidense de 12 meses, intereses que se devengarán en forma diaria hasta que se haga el pago, sea antes o después de una sentencia. En caso que la aplicación de dicha tasa de interés no sea procedente de acuerdo a la ley aplicable al lugar de ejecución del Contrato, se aplicará la tasa máxima que dicha ley permita.

5. EMBARQUE, ENTREGA, TÍTULO Y RIESGO DE PÉRDIDA

Los términos de entrega de los Productos son EXW (en el lugar designado por el Vendedor), según los Términos de Comercio Internacional (Incoterms 2000). El riesgo de pérdida o daños pasará al Comprador con la entrega realizada por el Vendedor al Comprador. El título de los Productos pasará al

Página 2 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 15: Wood Group ESP Catalogue

Comprador una vez que el Vendedor reciba el pago de fondos autorizados por las cantidades adeudadas con respecto al Contrato. El Vendedor puede hacer la entrega de los Productos mediante entregas parciales. Cada entrega parcial constituirá un Contrato separado y ninguna cancelación o terminación de un Contrato relacionado con una entrega parcial dará lugar al Comprador a rechazar o cancelar cualquier otro Contrato o entrega parcial. Se entiende que las fechas de entrega son estimadas y el tiempo y fecha de entrega no serán de la esencia del contrato en virtud de un aviso o de otro modo y dependen del pronto recibo por el Vendedor de toda la información y asistencia requeridas o solicitadas por el Vendedor para permitirle al Vendedor cumplir con sus obligaciones bajo el Contrato. El Vendedor no será responsable de los daños, pérdidas o gastos incurridos por el Comprador si el Vendedor no cumple con las fecha de entrega estimadas.

En caso que los Productos no sean recogidos por el Comprador en la fecha efectiva de la entrega, el Vendedor podrá (a su juicio exclusivo) colocar los Productos en un almacén/bodega al costo y riesgo exclusivos del Comprador.

6. FUERZA MAYOR

El Vendedor se reserva el derecho de diferir la fecha de entrega de los Productos y/o la fecha de suministro de los Servicios, de cancelar el Contrato, o de reducir el volumen de los Productos y/o modificar los alcances de los Servicios ordenados por el Comprador (sin responsabilidad para el Comprador), si se encuentra impedido o se retrasa en el cumplimiento de sus obligaciones debido a circunstancias que escapan a su control, en la medida que sea razonable, incluyendo, pero sin limitarse a, los desastres naturales, fuerzas naturales, terremotos, maremotos, derrumbes, inundaciones, rayos, huracanes, tifones, tormentas u otras inclemencias del tiempo no incluidas en un planeamiento normal, epidemias y plagas; cambios de las leyes o regulaciones, acciones del gobierno; actos de la autoridad civil o militar; incendios, explosiones, paros patronales, huelgas y/o disputas laborales (sea que estén o no relacionadas con los trabajadores de cualquiera de las partes); conmoción civil; protestas; guerras; emergencia nacional; disturbios, insurrección civil; actos de terrorismo, restricciones o retrasos en el transporte, restricciones o retrasos en la fabricación e incapacidad del Vendedor de obtener los suministros adecuados o apropiados de las fuentes usuales; o actos del Comprador que tengan como consecuencia la impracticabilidad comercial. En el caso de dicho retraso, la fecha de entrega y/o cumplimiento será diferida por un plazo equivalente al tiempo perdido debido a dicho retraso.

7. GARANTÍA

El Vendedor garantiza que los Productos fabricados por el Vendedor, siempre que sean debidamente almacenados, encargados, instalados, usados y mantenidos, y los Servicios suministrados por el Vendedor, estarán libres de defectos relacionados con los materiales o la mano de obra. La obligación del Vendedor bajo esta garantía se limitará a reponer o reparar la parte o partes de los Productos, a la opción del Vendedor, cuyo defecto en los materiales o mano de obra sea demostrado dentro de los doce (12) meses desde la fecha de instalación o dieciocho (18) meses desde la fecha de entrega, lo que ocurra primero; o a volver a suministrar los Servicios dentro de los doce (12) meses desde el suministro de los Servicios (“PLAZO DE GARANTÍA ”), siempre que el Comprador le dé al Vendedor pronto aviso de cualquier defecto y presente prueba sustancial y en una forma satisfactoria para el Vendedor (al juicio exclusivo de éste), incluyendo toda la información y documentación pertinentes necesarias para evaluar el rendimiento del pozo petrolero y equipo y las operaciones. Cualquier parte o partes defectuosas deben ser devueltas con el flete prepagado por el Comprador a un centro de servicios autorizado designado por el Vendedor para su inspección. El Vendedor enviará con el flete prepagado por el Comprador, productos en reposición de los Productos defectuosos, al destino de entrega indicado en la orden original. Los Productos devueltos al Vendedor por los cuales el Vendedor entregue productos en reposición bajo esta garantía se convertirán en propiedad del Vendedor.

LA GARANTÍA PRECEDENTE REMPLAZA TODA OTRA GARANTÍA, SEA ÉSTA EN FORMA ORAL, ESCRITA, EXPRESA, TÁCITA O LEGAL, Y EL VENDEDOR NO OFRECE NINGUNA GARANTÍA DE ADECUACIÓN DE UN BIEN PARA EL DESTINO DE USO PARTICULAR QUE

Página 3 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 16: Wood Group ESP Catalogue

QUIERA DARLE EL COMPRADOR, NI GARANTÍA DE COMERCIABILIDAD. LAS OBLIGACIONES DE GARANTÍA DEL VENDEDOR Y LOS MEDIOS LEGALES DE PROTECCIÓN O REPARACIÓN DEL COMPRADOR SON ÚNICA Y EXCLUSIVAMENTE LOS QUE ESTÁN EXPRESAMENTE PREVISTOS EN EL PRESENTE CONTRATO. ADICIONALMENTE EL COMPRADOR RENUNCIA A CUALQUIER Y TODO TIPO DE RECLAMO RELACIONADO CON VICIOS OCULTOS Y VICIOS REDHIBITORIOS. NO SE PRORROGARÁ EL PLAZO DE GARANTÍA UNA VEZ QUE LAS PARTES O PRODUCTOS HAYAN SIDO REPARADOS U OBJETO DE REPOSICIÓN O QUE LOS SERVICIOS HAYAN SIDO VUELTOS A SUMINISTRAR. DICHAS PARTES O PRODUCTOS O SERVICIOS PERMANECERÁN BAJO LA GARANTÍA ÚNICAMENTE POR LA PORCIÓN NO CADUCADA DEL PLAZO DE GARANTÍA. LA ÚNICA RESPONSABILIDAD DEL VENDEDOR SERÁ, A SU OPCIÓN, REPARAR O REPONER LAS PARTES O PRODUCTOS O VOLVER A SUMINISTRAR LOS SERVICIOS BAJO ESTA CONDICIÓN. EL VENDEDOR PUEDE, A SU JUICIO EXCLUSIVO, ACREDITAR A LA CUENTA DEL COMPRADOR LA PORCIÓN DE DICHAS PARTES O PRODUCTOS Y/O SERVICIOS QUE EL VENDEDOR DETERMINE SON DEFECTUOSOS. La garantía precedente no se aplica a: (a) los defectos causados en todo o en parte por, o atribuidos a materiales abrasivos, corrosión debido a fluidos agresivos, rayos, suministro de voltaje inapropiado, manejo indebido o aplicación errada; (b) Productos o partes que son normalmente consumidos en operación, o que tienen una vida normal naturalmente más corta que el PLAZO DE GARANTÍA; (c) alteraciones o reparaciones llevadas a cabo sin la previa aprobación por escrito del Vendedor, o uso de equipo y accesorios para un fin distinto para el cual está destinado dicho equipo y accesorios; (d) instalaciones realizadas por el Comprador, salvo que los ingenieros del Comprador hayan sido entrenados y debidamente certificados por el Vendedor; (e) instalaciones en las que el Comprador no haya ejercitado las prácticas de aplicación de ingeniería para los Productos, según fueron aprobados por el Proveedor; (f) Productos o Servicios defectuosos, cuando el Comprador siga haciendo uso de los Productos luego de haber tomado conocimiento del defecto, o del momento en que el Comprador debió haber tomado conocimiento de dicho defecto, lo que ocurra primero en el tiempo; (g) defectos que surjan o tengan conexión con información, dibujos, interpretaciones de diagramas, especificaciones técnicas o instrucciones proporcionadas por el Comprador al Vendedor.

8. LIMITACIÓN DE RESPONSABILIDAD

(i) PARA LOS FINES DE ESTA CONDICIÓN 8(i), EL TÉRMINO “DAÑO CONSECUENCIAL” SIGNIFICARÁ (EN CADA CASO, SEA O NO PREVISIBLE A LA FECHA DEL CONTRATO): (a) LAS PÉRDIDAS Y/O DAÑOS MEDIATOS, INDIRECTOS, ESPECIALES, INCIDENTALES, PUNITIVOS Y/O ESPECIALES; (b) EL LUCRO CESANTE, LA PÉRDIDA O DIFERIMIENTO DE PRODUCCIÓN, PÉRDIDA DE PRODUCTO, PÉRDIDA DE REPUTACIÓN, PÉRDIDA DE USO, PÉRDIDA DE INGRESOS, UTILIDADES EFECTIVAS O ANTICIPADAS, COSTO DE CAPITAL, EN CADA CASO SEA EN FORMA DIRECTA O INDIRECTA, RECLAMACIONES POR INTERRUPCIÓN DE SERVICIO O FALLA EN EL SUMINISTRO, COSTOS Y GASTOS INCURRIDOS EN CONEXIÓN CON LOS COSTOS OPERATIVOS DE MANO DE OBRA, TRANSPORTE O FUENTES DE SUMINISTROS O INSTALACIONES SUSTITUTAS, MANO DE OBRA EMPLEADA EN CONEXIÓN CON EL RETIRO Y REPOSICIÓN DE PRODUCTOS DENTRO DEL POZO O CUALESQUIERA OTRAS PÉRDIDAS O DAÑOS INCURRIDOS COMO CONSECUENCIA O EN CONEXIÓN CON LA INTERRUPCIÓN DEL SERVICIO, EN CADA CASO.

NO OBSTANTE DISPOSICIÓN EN CONTRARIO EN OTRA PARTE, EN NINGÚN CASO EL VENDEDOR SERÁ RESPONSABLE POR LOS DAÑOS CONSECUENCIALES Y EL COMPRADOR SERÁ RESPONSABLE Y LIBRARÁ, INDEMNIZARÁ, DEFENDERÁ Y MANTENDRÁ INDEMNE AL GRUPO DEL VENDEDOR FRENTE A LOS DAÑOS CONSECUENCIALES, AUN CUANDO FUERAN CAUSADOS POR LA NEGLIGENCIA O CULPA, SOLIDARIA, CONJUNTA, CONCURRENTE O PARCIAL

Página 4 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 17: Wood Group ESP Catalogue

DEL VENDEDOR, RESPONSABILIDAD OBJETIVA O RESPONSABILIDAD DEL FABRICANTE, Y SIN CONSIDERACIÓN DE LA FORMA DE ACCIÓN, SEA QUE SE TRATE DE RESPONSABILIDAD CONTRACTUAL, EXTRACONTRACTUAL (INCLUYENDO LA NEGLIGENCIA O CULPA), VIOLACIÓN DE GARANTÍA, INDEMNIZACIÓN, POR OPERACIÓN DE LA LEY, O DE OTRO MODO.

(ii) LA RESPONSABILIDAD TOTAL DEL VENDEDOR EN CUALQUIER ACCIÓN SEA

POR RESPONSABILIDAD CONTRACTUAL, EXTRACONTRACTUAL (INCLUYENDO LA NEGLIGENCIA SOLIDARIA, CONJUNTA O CONCURRENTE), O QUE DE OTRO MODO SURJA, SE RELACIONE O RESULTE DE LA FABRICACIÓN, VENTA, ENTREGA, REVENTA, REPARACIÓN, REPOSICIÓN O USO DEL PRODUCTO, O DEL SUMINISTRO DEL SERVICIO, O DEL CUMPLIMIENTO O FALTA DE CUMPLIMIENTO DEL CONTRATO, NO EXCEDERÁ DEL PRECIO RECIBIDO POR EL VENDEDOR POR EL PRODUCTO O PARTE DEL MISMO, O DEL COSTO DE SUMINISTRO DE CUALQUIER TRABAJO DE SERVICIO QUE DÉ LUGAR A LA ACCIÓN AL EFECTO, EL GRUPO DEL COMPRADOR RENUNCIA A INICIAR CUALQUIER ACCIÓN EN CONTRA DEL GRUPO DEL VENDEDOR PARA PERSEGUIR CUALQUIER INDEMNIZACIÓN POR SOBRE LOS LÍMITES PACTADOS EN ESTA CONDICIÓN, Y SE OBLIGA A INDEMNIZAR, DEFENDER Y MANTENER AL GRUPO DEL VENDEDOR LIBRE DE Y POR CUALQUIER RESPONSABILIDAD QUE EXCEDA EL LÍMITE DE RESPONSABILIDAD PACTADO EN ESTA SECCIÓN, AÚN CUANDO LA MISMA SEA GENERADA A FAVOR DE CUALQUIER MIEMBRO DEL GRUPO DEL COMPRADOR, O DE SUS CONTRATISTAS, SUBCONTRATISTAS, OPERADORES Y/O EL DUEÑO DEL POZO (EL TÉRMINO “DUEÑO DE POZO” DEBERÁ INCLUIR PERSONAS O ENTIDADES CON CUALQUIER TIPO DE DERECHOS O INTERÉS SOBRE EL POZO Y/O INSTALACIONES), Y AÚN CUANDO ESTOS DAÑOS SEAN GENERADOS POR LA NEGLIGENCIA DEL GRUPO DEL COMPRADOR Y/O DEL GRUPO DEL VENDEDOR.

(iii) EL COMPRADOR ENTIENDE Y ACUERDA QUE LAS LIMITACIONES A LA RESPONSABILIDAD PRECEDENTES SON PARTE ESENCIAL DEL CONTRATO Y QUE EN AUSENCIA DE DICHAS LIMITACIONES, LOS TÉRMINOS MATERIALES Y ECONÓMICOS DE ESTE CONTRATO SERÍAN ESENCIALMENTE DIFERENTES.

9. INDEMNIZACIÓN E INDEMNIDAD

Todas las exclusiones e indemnidades estipuladas bajo esta Condición 9 (salvo por las previstas bajo las Condiciones 9.1(c) y 9.2(c)) y la Condición 8 (i), se aplicarán sin consideración de la causa y no obstante la negligencia, culpa o violación de obligaciones (sea por ley o de otro modo) de la parte indemnizada o de cualquier otra entidad o parte y se aplicarán sin consideración de si la acción fue de carácter contractual, extracontractual o, de otro modo, por operación de la ley. Para los propósitos de las Condiciones 9.1(c) y 9.2 (c), “tercero” significará cualquier parte que no sea miembro del Grupo del Comprador ni del Grupo del Vendedor.

9.1. El Vendedor será responsable y librará, indemnizará, defenderá y mantendrá indemne al Grupo del Comprador frente a cualquier acción, pérdida, daño, costo (incluyendo los costos legales), gasto y otras responsabilidades, con respecto a lo siguiente: (a) Sujeto a la condición 9.2(d), la pérdida o daño a la propiedad (distinta a los Productos luego de su entrega conforme con la Condición 5) del Grupo del Vendedor, sea que con respecto a ésta el Grupo del Vendedor sea el propietario, o la haya contratado, arrendado o que por el contrario haya sido provista por el Grupo del Vendedor como consecuencia o en relación con el cumplimiento del Contrato; (b) Los daños a personas, incluyendo la muerte o enfermedad de cualquier persona empleada por el Grupo del Vendedor, como consecuencia o vinculados al cumplimiento del Contrato; (c) Sujeto a la condición 9.3, los daños a terceros, incluyendo la muerte, enfermedad, pérdida o daños a la propiedad de un tercero, en la medida que dichos daños, pérdidas o daños sean causados por la

Página 5 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 18: Wood Group ESP Catalogue

negligencia, culpa o violación de obligaciones (sea por operación de la ley o de otro modo) del Grupo del Vendedor.

9.2. El Comprador será responsable y librará, indemnizará, defenderá y mantendrá indemne al Grupo del Vendedor frente a cualquier acción, pérdida, daño, costo (incluyendo los costos legales), gasto y otras responsabilidades, con respecto a lo siguiente: (a) Pérdidas o daños a la propiedad del Grupo del Comprador, ya sea:-

(i) que el Grupo del Comprador sea el propietario, o (ii) que la propiedad haya sido contratada, arrendada o que haya sido, provista por o para

el Grupo del Comprador (incluyendo los Productos después de la entrega conforme con la Condición 5); y

(b) Los daños a personas, incluyendo la muerte o enfermedad de cualquier persona empleada por el Grupo del Comprador, como consecuencia o en relación con el cumplimiento o falta de cumplimiento del Contrato; y (c) Sujeto a cualesquiera otras estipulaciones del Contrato, los daños a terceros, incluyendo la muerte, enfermedad, pérdida o daños a la propiedad de un tercero, en la medida que dichos daños, pérdidas o daños sean causados por negligencia, culpa o violación de obligaciones (sea por operación de la ley o de otro modo) del Grupo del Comprador; y (d) A la opción del Vendedor, la reparación, reposición o reembolso del costo total del equipo, herramientas y/o instrumentos del Vendedor debido a su pérdida o daño en el fondo del pozo del Comprador durante el suministro de los Servicios, o debido a su pérdida o daño por la abrasión o corrosión ocasionada por efluentes del pozo, salvo que dicha pérdida o daños se deba a la negligencia del Vendedor. 9.3. No obstante la Condición 9.1, el Comprador será responsable y defenderá, indemnizará y mantendrá indemne al Grupo del Vendedor frente a toda acción que sea consecuencia del cumplimiento o falta de cumplimiento del Contrato en relación con lo siguiente, y sea o no que resulte de o este relacionada con la negligencia del Grupo del Vendedor: (i) pérdidas o daños al pozo o perforación o a cualquier instalación de producción de petróleo y gas de terceros; (ii) percolación o contaminación del depósito que se origine en el subsuelo o que provenga de la propiedad del Comprador o tercero no obstante la causa como se origine; (iii) voladura, incendio, explosión, depresión topográfica de cualquier pozo o depósito o cualquier otra condición no controlada de un pozo (incluyendo los costos para controlar un pozo descontrolado y la remoción de escombros); (iv) daños o fuga del producto o sustancia de una instalación, incluyendo un oleoducto u otra instalación subterránea. 9.4. No obstante disposición en contrario del Contrato, el Comprador será responsable y librará, indemnizará, defenderá y mantendrá indemne al Grupo del Vendedor frente a cualquier acción, pérdida, daño, costo (incluyendo los costos legales), gasto y otras responsabilidades, con respecto a los actos u omisiones de los empleados o agentes del Grupo del Vendedor en conexión con el cumplimiento de los Servicios (o cualquier parte de los Servicios), cuando, conforme con el Contrato, los empleados del Grupo del Vendedor estén bajo la supervisión, dirección o control del Comprador con respecto a dichos Servicios o parte de dichos Servicios.

10. FALTA DE ENTREGA La cantidad de cualquier envío de Productos conforme el registro del Vendedor como despachados desde la sede de operaciones del Vendedor u otro lugar designado será prueba concluyente de la cantidad recibida por el Comprador, salvo que el Comprador pueda ofrecer prueba demostrando lo contrario. El Vendedor no será responsable de la falta de entrega de Productos (aun cuando fuera causada por la negligencia del Vendedor), salvo que el Comprador dé un aviso por escrito al Vendedor sobre la falta de entrega dentro de cuarenta y ocho (48) horas de la fecha y hora en que el Producto hubiera sido recibido en el curso normal de las operaciones. Cualquier responsabilidad del Vendedor por falta de entrega de los Productos se limitará, a juicio exclusivo del Vendedor, ya sea a la reposición de los Productos o a la emisión de una nota de crédito contra una factura expedida por los Productos.

11. VIOLACIÓN DE PATENTE

Página 6 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 19: Wood Group ESP Catalogue

Si el Comprador es objeto de una reclamación o de otro modo toma conocimiento que un Producto o parte del mismo fabricado por el Vendedor infringe en forma real o presunta una patente u otro derecho de propiedad intelectual, el Comprador notificará de inmediato al Vendedor por escrito dándole información, asistencia y autoridad exclusiva para evaluar, defender y conciliar dicha acción o infracción potencial. El Vendedor entonces a su propio costo y opción: (a) conciliará dicha acción; (b) le facilitará al Comprador el derecho de usar dicho Producto; (c) lo repondrá o modificará para evitar la infracción; (d) lo retirará y reembolsará el precio de compra (incluyendo los costos de transportación e instalación), menos una cantidad razonable por concepto de depreciación; o (e) se defenderá ante dicha acción.

12. CANCELACIÓN Y CAMBIOS El Comprador no puede cancelar o reprogramar la fecha de entrega de los Productos y/o Servicios a ser provistos bajo el Contrato sin el previo consentimiento por escrito del Vendedor. En caso que el Vendedor dé dicho consentimiento, dicha cancelación o reprogramación con respecto a los Productos y/o Servicios por parte del Comprador dará lugar a un cobro al Comprador, el cual será determinado por el Vendedor. Todos los Productos especialmente diseñados o modificados que sean cancelados después del inicio de su fabricación serán objeto de un cargo por cancelación, el cual incluirá todos los costos y un margen razonable por el tiempo empleado, según lo determine el Vendedor. Los cargos de cancelación por accesorios y componentes abastecidos por terceros serán cobrados por el monto total del precio. El Vendedor, a su juicio exclusivo, ajustará el precio o las fechas de entrega, o hará las modificaciones que puedan requerirse como consecuencia de cualquier orden de cambio cuya expedición haya sido acordada por el Comprador y el Vendedor. No será válida la modificación de la orden de compra o Acuse de Recibo de la Orden u orden de cambio sino es aceptada por escrito por el Vendedor (a su juicio exclusivo).

13. RENUNCIA Cualquier renuncia por el Vendedor a una violación o incumplimiento de las obligaciones del Comprador bajo el Contrato, o cualquier omisión del Vendedor en ejercer los derechos que surjan bajo el Contrato, bajo ninguna circunstancia se interpretará como una renuncia a cualquier otra violación o incumplimiento posterior por parte del Comprador ni al derecho del Vendedor a ejercer sus derechos conforme el presente Contrato. En caso de cualquier incumplimiento por el Comprador, el Vendedor puede negarse a hacer más embarques. Si el Vendedor elige continuar haciendo entregas, la acción del Vendedor no constituirá una renuncia a dicho incumplimiento ni afectará los medios legales de protección o reparación del Vendedor por dicho incumplimiento.

14. TOTALIDAD DEL CONTRATO

El Acuse de Recibo de la Orden, las Condiciones Especiales y estos Términos y Condiciones Estándar constituyen la totalidad del contrato entre las partes con respecto a la venta de los Productos y/o Servicios y revoca todas las comunicaciones, representaciones o acuerdos, previos sean orales o escritos, con respecto al objeto del presente. Las representaciones o declaraciones previas, relacionadas con la venta de los Productos y/o Servicios, formuladas por un representante del Vendedor, que no estén contenidas en el presente, no serán vinculantes para el Vendedor.

15. CONTROL DE EXPORTACIONES El Comprador acepta que, salvo que se obtenga previa autorización del Departamento de Comercio de EE.UU., ni el Comprador ni sus subsidiarias exportarán, reexportarán o pondrán en circulación, directa o indirectamente, ningún Producto recibido del Vendedor, a ningún país o destino al cual esté prohibida la exportación, reexportación o puesta en circulación de la tecnología o Producto por las Regulaciones de la Administración de Exportación del Departamento de Comercio de EE.UU. (“EAR”, por sus siglas en inglés), o esté prohibido por las leyes de los EE.UU. o por leyes que no sean de los EE.UU. que sean aplicables.

El Comprador será responsable de obtener la licencia de exportación u otra documentación que sea necesaria antes de la exportación o reexportación de los Productos adquiridos del Vendedor bajo el Contrato. Asimismo, el Comprador dará un aviso sobre la necesidad de cumplir con dichas leyes y

Página 7 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 20: Wood Group ESP Catalogue

regulaciones a cualquier persona, firma o entidad que tenga razón para creer que obtendrá dichos Productos del Comprador con la intención de exportarlos. Cada parte obtendrá, a su propio costo, las licencias y documentos de exportación e importación que sean necesarios para cumplir con sus obligaciones bajo el Contrato. Si no se pueden obtener las aprobaciones, el Vendedor podrá dar por terminado, cancelado o por el contrario quedará exonerado del cumplimiento de las obligaciones que pueda tener bajo el Contrato. Cualquier clasificación de exportación hecha por el Vendedor será sólo para el uso interno del Vendedor y no se interpretará como una representación o garantía con respecto a la debida clasificación de exportación de cada Producto o si se necesita una licencia de exportación u otra documentación para la exportación del Producto. Esta Condición 15 sobrevivirá a la terminación del Contrato.

16. ÉTICA COMERCIAL

Ni el Vendedor ni el Comprador harán pagos ni tomarán ninguna acción que pudiera ser interpretada como dirigida al pago de dinero u otro artículo de valor en favor de un funcionario gubernamental, partido político o candidato de un partido político para los fines de influenciar los actos o inducir a un funcionario gubernamental para que haga uso de sus influencias para asistir en la obtención o retención de negocios en un país, en una forma que sea ilegal o que sujete al Vendedor a sanciones de carácter civil o penal, o que sean incompatibles con la Política de Ética Comercial del Vendedor.

17. CESIÓN

El Vendedor podrá dar en cesión el Contrato o cualquier parte del mismo a cualquier persona, firma o empresa. El Comprador no tendrá derecho a dar en cesión el Contrato ni ninguna parte del mismo sin el previo consentimiento por escrito del Vendedor.

18. ARBITRAJE

Cualquier disputa que surja o tenga relación con el Contrato, incluyendo una disputa en cuanto a la validez de los Términos y Condiciones Estándar y de esta Condición 18, será resuelta mediante arbitraje en Houston realizado en español por un solo árbitro, de conformidad con las Reglas del Tribunal Internacional de Arbitraje de Londres o LCIA, siglas en inglés de “The London Court of International Arbitration”).

19. LEY APLICABLE Estos Términos y Condiciones Estándar se interpretarán para todos los efectos y se les dará efecto legal de conformidad con las leyes de [país del Vendedor], no obstante los principios de conflicto de leyes. No será aplicable la Convención de las Naciones Unidas sobre los Contratos para la Venta Internacional de Mercaderías.

20. ESTIPULACIONES VARIAS Todas las muestras, dibujos, materiales descriptivos, especificaciones y publicidad proporcionados por el Vendedor y las descripciones o ilustraciones contenidas en los catálogos o folletos del Vendedor son publicados o emitidos con el único fin de dar una idea aproximada de los Productos y/o Servicios descritos en los mismos. Éstos no formarán parte del Contrato.

A su propio costo, el Comprador obtendrá los permisos o cualquier otra autorización (incluyendo, con carácter enunciativo pero no limitativo, los permisos de trabajos y visas para empleados del Vendedor), los cuales pueden ser requeridos para permitirle al Vendedor cumplir con los Servicios. El Comprador acepta indemnizar al Vendedor frente los costos, reclamaciones, acciones, demandas o gastos incurridos o sufridos en conexión con el incumplimiento del Comprador en obtener los permisos o autorizaciones requeridos para cumplir con los Servicios.

Si una corte, tribunal u organismo administrativo de jurisdicción competente encontrara que una estipulación del Contrato es en todo o en parte ilegal, inválida, nula, anulable, inejecutable o irrazonable, en la medida de dicha ilegalidad, invalidez, nulidad, anulabilidad, inejecutabilidad o irrazonabilidad, la estipulación se considerará divisible, y el resto de las estipulaciones del Contrato, como el resto de dicha estipulación, continuarán en pleno efecto y vigor.

Página 8 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 21: Wood Group ESP Catalogue

Estos Términos y Condiciones Estándar están sujetos a cambio sin previo aviso por escrito, en cualquier momento y cuando convenga, a juicio exclusivo del Vendedor. Todas las comunicaciones entre las partes acerca del Contrato se harán por escrito y se entregarán en forma personal o se enviarán por fax a la oficina registrada o a cualquier otra dirección según sea notificado a la otra parte. Las comunicaciones entregadas en forma personal se considerarán recibidas el día de la entrega o, si son enviadas por fax, el día hábil y a la hora de la transmisión, o por el contrario, el siguiente día hábil.

Página 9 de 9 WG ESP- Términos y Condiciones de Venta Estandar Internacional (0 3) Clean (2)

Page 22: Wood Group ESP Catalogue

Wood Group ESP, Inc. North American Operations

Wood Group ESP Corporate Headquarters & Operations Corporate Sales Office 5500 S.E.59th St.(73135) 19416 Park Row, Suite 100 P.O. Box 15070 (73155) Houston,TX 77084 USA Oklahoma City, OK USA Telephone:(281) 492-5100 Telephone: (405) 670-1431 Facsimile: (281) 492-8107

(800) 723-3771 Facsimile: (405) 670-5463 E-mail: [email protected] www.woodgroup-esp.com

Wood Group ESP Sales and Service Locations

Canada Wood Group ESP (Canada) Ltd Bay 6, 360 Aquaduct Dr. Brooks, Alberta T1R 1E4 Canada Telephone: (403) 501-5822 Facsimile: (403) 501-5823 Wood Group ESP (Canada) Ltd 300,1015-4th St. SW Calgary, Alberta T2R 1J4 Canada Telephone: (403) 263-7166 Facsimile: (403) 263-7211 Wood Group ESP (Canada) Ltd 3917 81 Avenue Leduc, Alberta T9E 8S6 Canada Telephone: (780) 955-2165

(888) 586-8909 Facsimile: (780) 955-9487 Colorado 410 17th Street, Suite 1260 Denver, CO 80202 USA Telephone: (303) 350-2111

(800) 535-0310 Facsimile: (303) 350-2112 Mississippi 45 Jerry Doggett Dr. Laurel, MS 39443 USA Telephone: (601) 649-2030

(800) 488-9260 Facsimile: (601) 649-8819

Wood Group ESP, Inc.

New Mexico 509 Commerce Rd. Artesia, NM 88210 USA Telephone: (505) 746-4614 Facsimile: (505)746-4519

8426 North Dal Paso Hobbs, NM 88242 USA Telephone: (505) 392-7999 Facsimile: (505) 391-8190

Oklahoma 5500 S.E.59th St.(73135) P.O. Box 15070 (73155) Oklahoma City, OK USA Telephone: (405) 670-1431 (800) 723-3771 Facsimile: (405) 670-5463

1739 Hardcastle Ind. Blvd. P.O. Box 1680 Purcell, OK 73080 USA Telephone: (405) 527-1566

(800) 256-5058 Facsimile: (405) 527-7161

The ESP Specialists

Texas 1700 S.W. Mustang Dr. P.O. Box 947 Andrews, TX 79714 USA Telephone: (432) 523-9701 Facsimile: (432) 523-9700

19416 Park Row, Suite 100 Houston,TX 77084 USA Telephone: (281) 492-5100 Facsimile: (281) 492-8107

2707 S.County Rd.1208 (79706) P.O. Box 80130 (79708) Midland, TX USA Telephone: (432) 699-7401

(800) 749-7402 Facsimile: (432) 699-4159

2507 25th St. (79549) P.O. Box 916 (79550) Snyder, TX USA Telephone: (325) 573-8101 Facsimile: (325) 573-1616

Wyoming 1845 N. Oilfield Center Casper, WY 82604 Telephone: (307) 234-4495

(800) 535-0306 Facsimile: (307) 234-4497

www.woodgroup-esp.com

Product Catalog - Facilities - Copyright Wood Group ESP, Inc. – October 2009 revised October, 2009 Page-1

Page 23: Wood Group ESP Catalogue

Wood Group ESP, Inc. Wood Group ESP International Operations

ASIA PACIFIC Indonesia PT ESP Mulia Indonesia Balai Raja Industrial Park JL. Raya, Duri- Pekanbaru Road, KM 11 Duri, Riau Province, Sumatra 28884 Telephone:+62-765-561904 Facsimile: +62-765-561923 PT Indobornusa Mandiri Wisma Staco 6th Floor Jl.Casablanca Kav.18 Jakarta, Indonesia 12870 Telephone: +62 (21) 8370-2455 Facsimile: +62 (21) 831-2345 Singapore PTE Ltd. Shaw Tower #28-09 100 Beach Road Singapore, 189702 Telephone: +65-6396-3626 Facsimile: +65-6396-5362

EUROPE / AFRICA

Africa EDGO-Trading TChad 1033, Rue de la Gendarmerie BP 5496, N’Djamena, Tchad Telephone: +235 524 757

+44 20707 42974 +44 20707 41777

Facsimile: +235 524 757 United Kingdom Maersk House, Greenbank Rd East Tullos, Aberdeen AB12 3BR Scotland Telephone: +44-1224-21 6636 Facsimile: +44-1224-21 6770 England Telephone: +44-1564-77-1739 Facsimile: +44-1564-77-1739

Wood Group ESP, Inc.

LATIN AMERICA Argentina Reconquista 1016 Piso 6 Buenos Aires, 1003 Argentina Telephone:+54-11-4-311-9411 Facsimile: +54-11-4-311-2980

Dalle Mura 150 Comodoro Rividavia Chubut 9000 Argentina Telephone:+54-297-446-8254 Facsimile: +54-297-447-8377 Brazil 65 Rua Antonio Vita Jardim Vonfiglioli CEP- 05593-080 Sao Paulo , Brazil Telephone:+55-11-3731-2999 Facsimile: +55-11-3731-2998 Colombia Wood Group Colombia, Colombser SA Carrera 11A #93-97 Office 204 Bogota, Colombia, Sur America Telephone:+57-1-621-2424 Facsimile: +57-1-621-2275 Ecuador Panamericana Norte Km. 12 1/2 entre pasaje Alfonso Moncayo y calle El Arenal, Parque Delta Quito Ecuador Telephone:+593-2-2428-211 Facsimile: +593-2-2428-213 Venezuela Avenidad Cuatricentenario Barinas Sede De La Toyota Barinas, EdoBarinos, Venezuela Codigo Postal 5201 Telephone:+58-273-546-1241 Facsimile: +58-273-546-2653

Av Intercomunal antigua sede Motoriente, El Tigre - Tigrito Edo Anzoategui, Venezuela Telephone:+58-283-241-7151 Facsimile: +58-283-241-8613

The ESP Specialists

Venezuela -continued Zona Industrial Segunda Km 6 ½ via a Perija Sector El Callao, Municipio San Francisco Maracaibo, Edo Zulia, Venezuela 4001 Telephone:+58-261-200-9200 Facsimile: +58-261-736-1993

MIDDLE EAST Dubai Oilfield Supply Center Ltd. Jebel Ali Free Zone Building No.50 P.O. Box 18131 Dubai, United Arab Emirates Telephone:+971-4-883-7595 Facsimile: +971-4-883-7579 Kuwait c/o Klalid Y. Al Fulaij Est. P.O. Box 22414 Safat 13085 Kuwait Telephone:(965)398-3639-2810 Facsimile: (965)398-3639 2811 Oman c/o Oman Oilfield Supply Center P.O. Box 104 Shati Al Qurum, Sultanate of Oman Telephone: +968-605501, 691091 Facsimile: +968-605784

RUSSIA Moscow #8 Leningradsky Prospect Office #4012-4015 Moscow, Russia 125040 Telephone: +7-502-937-6641 Facsimile: +7-502-937-6642

Wood Group ESP Service, Ltd #5 Kuzovatkin Street Nizhnevartovsk, Tyumen Region 628606 Telephone: +7 3466-416-195 Facsimile: +7 3466-416-295

www.woodgroup-esp.com

Page-2 revised October, 2009 Product Catalog - Facilities - Copyright Wood Group ESP, Inc. - October, 2009

Page 24: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

ENGINEERING DATA TA-1200 60 HZ

114.3 MM4-1/2 IN

6000 PSI6000 PSI6000 PSI

85.73MM3-3/8 IN

125 HP

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

Pump Performance Curve for TA-1200 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

78 HP

0

5

10

15

20

Ft

2

4

6

MHead

0 200 400 600 800 1000 1200 1400 1600 1800

0%

20%

40%

60%

80%

BPD

50 100 150 200 250M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.2

0.4

0.6

0.8

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 25: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-14 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TA-1200 50 HZ

Pump Performance Curve for TA-1200 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

4-1/2 IN114.3 MM

3-3/8 IN 5/8 IN85.73MM 15.88MM

60 HZ 50 HZ

6000 PSI 192 HP 160 HP

6000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

M

5

10

15

FtHead

0 50 100 150 200 250

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

M3/DAY

250 500 750 1000 1250 1500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

1.0

1.1

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 26: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 35 15.9 13 9126672 3.5 1.07 57 25.9 27 9126753 4.9 1.49 81 36.7 45 9126834 6.3 1.92 104 47.2 61 9126915 7.8 2.38 128 58.1 77 912709 70 1135526 9.1 2.77 152 68.9 93 912717 86 1137327 10.5 3.20 174 78.9 108 9127258 11.9 3.63 193 87.5 124 9127339 13.3 4.05 221 100.2 140 91274110 14.8 4.51 244 110.7 156 912758 145 113735

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5Coupling for Intake or GS 0.25 0.08 0.4 0.18Pump to Pump Coupling - FLT 0.18 0.05 0.18 0.08

Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15

TA-1200 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

1021310

120555914341912022

Page 27: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-16 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TA-1200 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

40

Ft

2

4

6

8

10

12

MHead

0 500 1000 1500 2000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 28: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17

ENGINEERING DATA TA-1500 60 HZ

114.3 MM4-1/2 IN

6000 PSI6000 PSI6000 PSI

85.73MM3-3/8 IN

167 HP

50 HZ60 HZ

11/16 IN17.46MM

125 HP200 HP255 HP 213 HP

Pump Performance Curve for TA-1500 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

104 HP

0

5

10

15

Ft

2

4

MHead

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800

0%

25%

50%

75%

BPD

50 100 150 200 250 300 350 400M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.5

1.0

1.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 29: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-18 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TA-1500 50 HZ

Pump Performance Curve for TA-1500 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

4-1/2 IN114.3 MM

3-3/8 IN 11/16 IN85.73MM 17.46MM

60 HZ 50 HZ

6000 PSI 255 HP 213 HP

6000 PSI 125 HP 104 HP6000 PSI 200 HP 167 HP

0

0.5

1

1.5

2

2.5

3

3.5

4

M

5

10

Ft

Head

0 50 100 150 200 250 300 350

0%

10%

20%

30%

40%

50%

60%

70%

80%

M3/DAY

250 500 750 1000 1250 1500 1750 2000 2250BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

1.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 30: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 38 17.2 10 912766 9 1406012 3.5 1.07 65 29.5 23 912774 21 1406023 4.9 1.49 91 41.3 35 912782 32 1406034 6.3 1.92 118 53.5 48 912790 45 1406045 7.8 2.38 145 65.8 60 912808 56 1406056 9.1 2.77 172 78.0 73 912816 68 1406067 10.5 3.20 198 89.8 85 912824 79 1406078 11.9 3.63 226 102.5 96 912832 91 1406089 13.3 4.05 252 114.3 110 912840 103 14060910 14.8 4.51 279 126.6 123 912857 114 140610

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5Coupling for Intake or GS 0.2 0.06 0.4 0.18Pump to Pump Coupling - FLT 0.2 0.06 0.18 0.08

Pump to Pump Coupling - CMP 0.2 0.06 0.18 0.08

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19

TA-1500 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

1021310

120556934182120556

Page 31: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-20 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TA-1500 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

12MHead

0 500 1000 1500 2000 2500 3000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300 400M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 32: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

78 HP

Pump Performance Curve for TA-400 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

ENGINEERING DATA TA-400 60 HZ

114.3 MM4-1/2 IN

6000 PSI6000 PSI6000 PSI

85.73MM3-3/8 IN

125 HP

0

5

10

15

20

Ft

2

4

6

MHead

0 100 200 300 400 500 600 700

0%

20%

40%

60%

80%

Efficiency

Power

BPD

25 50 75 100M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

HPMTR

LOAD

Qmin BEP Qmax

Head

CAPACITY

Page 33: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

6000 PSI 192 HP 160 HP

6000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

5/8 IN85.73MM 15.88MM

60 HZ

4-1/2 IN114.3 MM

3-3/8 IN

Pump Performance Curve for TA-400 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TA-400 50 HZ

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

M

5

10

15

FtHead

0 10 20 30 40 50 60 70 80 90

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

Head

M3/DAY

50 100 150 200 250 300 350 400 450 500 550BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.0

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

HPMTR

LOAD

Qmin BEP Qmax

Efficiency

Power

CAPACITY

Page 34: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 34 15.4 16 917378 15 113871 15 1139812 3.5 1.07 55 24.9 35 917385 33 113872 33 1139823 4.9 1.49 75 34.0 54 917393 50 113873 50 1139834 6.3 1.92 96 43.5 74 917401 69 113874 69 1139845 7.8 2.38 118 53.5 93 917419 86 113875 86 1139856 9.1 2.77 139 63.0 112 917427 104 1138767 10.5 3.20 160 72.6 132 917435 122 1138778 11.9 3.63 181 82.1 151 917443 139 1138789 13.3 4.05 202 91.6 157 11387910 14.7 4.48 223 101.2 174 113880

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5Coupling for Intake or GS 0.25 0.08 0.4 0.18Pump to Pump Coupling - FLT 0.18 0.05 0.18 0.08

Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

1021310

120555914341912022

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TA-400 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 35: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TA-400 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

40

45

Ft

2

4

6

8

10

12

14

MHead

0 100 200 300 400 500 600 700 800 900

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD25 50 75 100 125M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 36: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

78 HP

Pump Performance Curve for TA-550 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

ENGINEERING DATA TA-550 60 HZ

114.3 MM4-1/2 IN

6000 PSI6000 PSI6000 PSI

85.73MM3-3/8 IN

125 HP

0

5

10

15

20

25

30

Ft

2

4

6

8

MHead

0 100 200 300 400 500 600 700 800 900

0%

10%

20%

30%

40%

50%

60%

Efficiency

Power

BPD

25 50 75 100 125M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

0.6

HPMTR

LOAD

Qmin BEP Qmax

Head

CAPACITY

Page 37: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

6000 PSI 192 HP 160 HP

6000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

5/8 IN85.73MM 15.88MM

60 HZ

4-1/2 IN114.3 MM

3-3/8 IN

Pump Performance Curve for TA-550 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TA-550 50 HZ

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

M

5

10

15

Ft

Head

0 25 50 75 100 125

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%Head

M3/DAY

100 200 300 400 500 600 700BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.0

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

HPMTR

LOAD

Qmin BEP Qmax

Efficiency

Power

CAPACITY

Page 38: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 38 17.2 16 912873 15 113961 15 1031402 3.5 1.07 63 28.6 35 912881 33 113962 33 1031413 4.9 1.49 88 39.9 54 912899 50 113963 50 1031424 6.3 1.92 107 48.5 74 912907 69 113964 59 1031435 7.8 2.38 141 64.0 93 912915 86 113965 86 1031446 9.1 2.77 167 75.8 112 912923 104 1139667 10.5 3.20 193 87.5 132 912931 122 1139678 11.9 3.63 219 99.3 151 912949 139 1139689 13.3 4.05 245 111.1 170 912956 157 11396910 14.8 4.51 271 122.9 190 912964 174 113970

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5Coupling for Intake or GS 0.25 0.08 0.4 0.18Pump to Pump Coupling - FLT 0.18 0.05 0.18 0.08

Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

1021310

120555914341912022

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TA-550 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 39: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-8 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TA-550 1 stage, S.G. = 1

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 200 400 600 800 1000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD50 100 150M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 40: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

ENGINEERING DATA TA-900 60 HZ

114.3 MM4-1/2 IN

6000 PSI6000 PSI6000 PSI

85.73MM3-3/8 IN

125 HP

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

Pump Performance Curve for TA-900 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

78 HP

0

5

10

15

20

Ft

2

4

6

MHead

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500

0%

20%

40%

60%

80%

BPD

25 50 75 100 125 150 175 200 225M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 41: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 3.375” / 85.8 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-10 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TA-900 50 HZ

Pump Performance Curve for TA-900 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

4-1/2 IN114.3 MM

3-3/8 IN 5/8 IN85.73MM 15.88MM

60 HZ 50 HZ

6000 PSI 192 HP 160 HP

6000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

M

5

10

15

Ft

Head

0 25 50 75 100 125 150 175 200

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

M3/DAY

100 200 300 400 500 600 700 800 900 1000 1100 1200BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.0

0.1

0.1

0.1

0.1

0.2

0.2

0.2

0.2

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 42: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 38 17.2 16 914499 15 140551 15 1031492 3.5 1.07 63 28.6 35 912576 33 140552 33 1031503 4.9 1.49 88 39.9 54 912584 50 140553 50 1031514 6.3 1.92 107 48.5 74 912592 69 140554 69 1031525 7.8 2.38 141 64.0 93 912618 86 140555 86 1031536 9.1 2.77 167 75.8 112 912618 104 1405567 10.5 3.20 193 87.5 132 912626 122 1405578 11.9 3.63 219 99.3 151 912634 139 1405589 13.3 4.05 245 111.1 170 912642 157 14055910 14.8 4.51 271 122.9 190 912659 174 140560

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.5 0.15 10 4.5Coupling for Intake or GS 0.25 0.08 0.4 0.18Pump to Pump Coupling - FLT 0.18 0.05 0.18 0.08

Pump to Pump Coupling - CMP 0.18 0.05 0.18 0.08

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

TA-900 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

1021310

120555914341912022

Page 43: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-12 Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TA-900 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

40

Ft

2

4

6

8

10

12

MHead

0 200 400 600 800 1000 1200 1400 1600

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD50 100 150 200 250M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 44: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-21

104 HP

Pump Performance Curve for TD-1250 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

11/16 IN17.46MM

125 HP200 HP255 HP 213 HP

ENGINEERING DATA TD-1250 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

167 HP

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

MHead

0 250 500 750 1000 1250 1500 1750 2000

0%

10%

20%

30%

40%

50%

60%

70%

BPD

50 100 150 200 250 300M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

1.3

1.5

1.8

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 45: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-22 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 255 HP 213 HP

5000 PSI 125 HP 104 HP6000 PSI 200 HP 167 HP

11/16 IN101.60MM 17.46MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-1250 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-1250 50 HZ

0

1

2

3

4

5

6

7

M

5

10

15

20

Ft

Head

0 25 50 75 100 125 150 175 200 225 250

0%

10%

20%

30%

40%

50%

60%

70%

M3/DAY

100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 46: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 14 192421 13 192381 13 192391 12 1924112 3.5 1.07 74 33.6 30 192422 29 192382 29 192392 27 1924123 4.9 1.49 105 47.6 47 192423 45 192383 43 192393 41 1924134 6.3 1.92 135 61.2 63 192424 62 192384 58 192394 56 1924145 7.8 2.38 166 75.3 79 192425 78 192385 73 192395 71 1924156 9.2 2.80 196 88.9 95 192426 94 192386 87 192396 87 1924167 10.6 3.23 226 102.5 111 192427 102 1923978 12 3.66 257 116.6 128 192428 117 1923989 13.4 4.08 287 130.2 144 192429 131 19239910 14.8 4.51 318 144.2 160 192430 146 19240011 16.2 4.94 348 157.8 176 192431 161 19240112 17.6 5.36 378 171.5 192 192432 175 192402

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.3 0.09 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-23

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120556934182934232

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-1250 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 47: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-24 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-1250 1 stage, S.G. = 1

0

10

20

30

40

50

60

70

4

8

12

16

20

24

0 500 1000 1500 2000 2500

FtMHead

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 48: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

ENGINEERING DATA TD-150 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

58 HP

50 HZ60 HZ

1/2 IN12.69MM

44 HP70 HP90 HP 75 HP

Pump Performance Curve for TD-150 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

37 HP

0

5

10

15

20

25

Ft

2

4

6

8

MHead

0 50 100 150 200 250 300 350

0%

10%

20%

30%

40%

50%

BPD

10 20 30 40 50M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 49: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TD-150 50 HZ

Pump Performance Curve for TD-150 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

5-1/2 IN139.7 MM

4 IN 1/2 IN101.60MM 12.69MM

60 HZ 50 HZ

8000 PSI 90 HP 75 HP

5000 PSI 44 HP 37 HP6000 PSI 70 HP 58 HP

0

1

2

3

4

5

M

5

10

15

FtHead

0 10 20 30 40

0%

10%

20%

30%

40%

50%

M3/DAY

50 100 150 200 250BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.1

0.2

0.2

0.3

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 50: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 19 150701 19 150691 17 1707912 3.5 1.07 74 33.6 40 150702 40 150692 35 1707923 4.9 1.49 105 47.6 60 150703 60 150693 54 1707934 6.3 1.92 135 61.2 81 150704 81 150694 73 1707945 7.8 2.38 166 75.3 102 150705 93 1707956 9.2 2.80 196 88.9 122 150706 111 1707967 10.6 3.23 226 102.5 143 150707 131 1707978 12 3.66 257 116.6 164 150708 149 1707989 13.4 4.08 287 130.2 184 150709 169 17079910 14.8 4.51 318 144.2 205 150710 187 17061211 16.2 4.94 348 157.9 226 150711 207 17080112 17.6 5.36 378 171.5 247 150712 225 170802

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.23 0.07 0.77 0.35Pump to Pump Coupling - FLT 0.19 0.07 0.72 0.33

Pump to Pump Coupling - CMP 0.19 0.07 0.72 0.33

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

TD-150 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

10085561008556100572

Page 51: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-150 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

40

45

Ft

2

4

6

8

10

12

14

MHead

0 50 100 150 200 250 300 350 400 450 500

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD10 20 30 40 50 60 70M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 52: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-25

104 HP

Pump Performance Curve for TD-1750 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

11/16 IN17.46MM

125 HP200 HP255 HP 213 HP

ENGINEERING DATA TD-1750 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

167 HP

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

MHead

0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000

0%

10%

20%

30%

40%

50%

60%

70%

BPD

50 100 150 200 250 300 350 400 450M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

1.3

1.5

1.8

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 53: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-26 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 255 HP 213 HP

5000 PSI 125 HP 104 HP6000 PSI 200 HP 167 HP

11/16 IN101.60MM 17.46MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-1750 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-1750 50 HZ

0

1

2

3

4

5

6

M

5

10

15

20

Ft

Head

0 50 100 150 200 250 300 350 400

0%

13%

25%

38%

50%

63%

75%

M3/DAY

250 500 750 1000 1250 1500 1750 2000 2250 2500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 54: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 8 939801 7 130181 8 110651 7 1302012 3.5 1.07 74 33.6 16 939819 15 130182 16 110652 15 1302023 4.9 1.49 105 47.6 25 939827 24 130183 25 110653 24 1302034 6.3 1.92 135 61.2 33 939835 32 130184 33 110654 32 1302045 7.8 2.38 166 75.3 41 939868 41 130185 41 110655 41 1302056 9.2 2.80 196 88.9 50 939876 49 130186 50 110656 49 1302067 10.6 3.23 226 102.5 58 939884 57 130187 58 110657 57 1302078 12 3.66 257 116.6 67 939892 66 130188 67 110658 66 1302089 13.4 4.08 287 130.2 75 939900 74 130189 75 110659 74 13020910 14.8 4.51 318 144.2 84 939918 83 130190 84 110660 83 13021011 16.2 4.94 348 157.8 92 939926 91 130191 92 110661 91 13021112 17.6 5.36 378 171.5 100 939934 100 130192 100 110662 100 13021213 19 5.79 408 185.1 108 939942 108 11066314 20.4 6.22 438 198.7 116 939959 116 11066415 21.8 6.64 468 212.3 125 939967 125 110665

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-27

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120556934182934232

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-1750 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 55: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-28 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-1750 1 stage, S.G. = 1

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 500 1000 1500 2000 2500 3000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300 400 500M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 56: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-29

104 HP

Pump Performance Curve for TD-2200 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

11/16 IN17.46MM

125 HP200 HP255 HP 213 HP

ENGINEERING DATA TD-2200 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

167 HP

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

MHead

0 500 1000 1500 2000 2500 3000 3500 4000

0%

10%

20%

30%

40%

50%

60%

70%

BPD

100 200 300 400 500 600M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

1.3

1.5

1.8

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 57: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-30 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 255 HP 213 HP

5000 PSI 125 HP 104 HP6000 PSI 200 HP 167 HP

11/16 IN101.60MM 17.46MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-2200 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-2200 50 HZ

0

1

2

3

4

5

6

7

M

5

10

15

20

Ft

Head

0 50 100 150 200 250 300 350 400 450 500 550

0%

13%

25%

38%

50%

63%

75%

88%

M3/DAY

250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 58: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 8 130981 8 132941 7 1329612 3.5 1.07 74 33.6 16 130982 15 131782 16 132942 15 1329623 4.9 1.49 105 47.6 25 130983 24 131783 25 132943 24 1329634 6.3 1.92 135 61.2 33 130984 33 132944 32 1329645 7.8 2.38 166 75.3 41 130985 41 131785 41 132945 41 1329656 9.2 2.80 196 88.9 50 130986 49 131786 50 132946 49 1329667 10.6 3.23 226 102.5 58 130987 57 131787 58 132947 57 1329678 12 3.66 257 116.6 67 130988 66 131788 67 132948 66 1329689 13.4 4.08 287 130.2 75 130989 74 131789 75 132949 74 13296910 14.8 4.51 318 144.2 84 130990 83 131790 84 132950 83 13297011 16.2 4.94 348 157.8 92 130991 91 131791 92 132951 91 13297112 17.6 5.36 378 171.5 100 130992 100 131792 100 132952 100 13297213 19 5.79 408 185.1 108 130993 108 13295314 20.4 6.22 438 198.7 116 130994 116 13295415 21.8 6.64 468 212.3 125 130995 125 132955

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-31

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120556934182934232

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-2200 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 59: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-32 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-2200 1 stage, S.G. = 1

0

10

20

30

40

50

60

Ft

4

8

12

16

20

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300 400 500 600 700M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 60: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

ENGINEERING DATA TD-150 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

125HP

50 HZ60 HZ

1/2 IN12.69MM

94HP150HP192HP 160HP

Pump Performance Curve for TD-300 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

78HP

0

5

10

15

20

25

Ft

2

4

6

8

MHead

0 50 100 150 200 250 300 350 400 450 500 550 600 650

0%

10%

20%

30%

40%

50%

BPD

10 20 30 40 50 60 70 80 90 100M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 61: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TD-150 50 HZ

Pump Performance Curve for TD-300 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

5-1/2 IN139.7 MM

4 IN 1/2 IN101.60MM 12.69MM

60 HZ 50 HZ

8000 PSI 192HP 160HP

5000 PSI 94HP 78HP6000 PSI 150HP 125HP

0

1

2

3

4

5

M

5

10

15

Ft

Head

0 10 20 30 40 50 60 70 80

0%

20%

40%

60%

80%

100%

M3/DAY

50 100 150 200 250 300 350 400 450 500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.1

0.2

0.2

0.3

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 62: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 15 130881 14 130901 15 130921 13 1309412 3.5 1.07 74 33.6 32 130882 31 130902 31 130922 29 1309423 4.9 1.49 105 47.6 49 130883 48 130903 47 130923 45 1309434 6.3 1.92 135 61.2 66 130884 65 130904 63 130924 61 1309445 7.8 2.38 166 75.3 83 130885 82 130905 78 130925 76 1309456 9.2 2.80 196 88.9 100 130886 98 130906 93 130926 91 1309467 10.6 3.23 226 102.5 117 130887 109 1309278 12 3.66 257 116.6 133 130888 125 1309289 13.4 4.08 287 130.2 150 130889 140 13092910 14.8 4.51 318 144.2 167 130890 156 13093011 16.2 4.94 348 157.9 184 130891 171 13093112 17.6 5.36 378 171.5 201 130892 187 130932

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.23 0.07 0.77 0.35Pump to Pump Coupling - FLT 0.19 0.07 0.72 0.33

Pump to Pump Coupling - CMP 0.19 0.07 0.72 0.33

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

TD-300 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120555926477934281

Page 63: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-8 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-300 1 stage, S.G. = 1

0

5

10

15

20

25

30

35

40

45

Ft

2

4

6

8

10

12

14

MHead

0 100 200 300 400 500 600 700 800

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD25 50 75 100 125M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 64: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-33

213 HP

Pump Performance Curve for TD-3000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

ENGINEERING DATA TD-3000 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

342 HP

0

5

10

15

20

25

30

Ft

2

4

6

8

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

0%

15%

30%

45%

60%

75%

90%

BPD

100 200 300 400 500 600 700M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.5

1.0

1.5

2.0

2.5

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 65: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-34 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 522 HP 435 HP

5000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

7/8 IN101.60MM 22.22MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-3000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-3000 50 HZ

0

1

2

3

4

5

M

5

10

15

Ft

Head

0 100 200 300 400 500 600 700

0%

15%

30%

45%

60%

75%

M3/DAY

500 1000 1500 2000 2500 3000 3500 4000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

1.3

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 66: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 6 936260 6 130241 6 110671 6 1302612 3.5 1.07 74 33.6 14 936278 14 130242 14 110672 14 1302623 4.9 1.49 105 47.6 21 936286 21 130243 21 110673 21 1302634 6.3 1.92 135 61.2 29 936294 29 130244 29 110674 29 1302645 7.8 2.38 166 75.3 36 936302 36 130245 36 110675 36 1302656 9.2 2.80 196 88.9 44 936310 44 130246 44 110676 44 1302667 10.6 3.23 226 102.5 51 936328 51 130247 51 110677 51 1302678 12 3.66 257 116.6 59 936336 59 130248 59 110678 59 1302689 13.4 4.08 287 130.2 66 936344 66 130249 66 110679 66 13026910 14.8 4.51 318 144.2 74 936351 74 130250 74 110680 74 13027011 16.2 4.94 348 157.8 81 936369 81 130251 81 110681 81 13027112 17.6 5.36 378 171.5 89 936377 89 130252 89 110682 89 13027213 19 5.79 408 185.1 96 936385 96 130253 96 110683 96 13027314 20.4 6.22 438 198.7 104 936393 104 110684 100 13027415 21.8 6.64 468 212.3 111 936401 111 110685

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-35

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120557934026934026

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-3000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 67: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-36 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-3000 1 stage, S.G. = 1

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 1000 2000 3000 4000 5000 6000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD250 500 750M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 68: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-37

ENGINEERING DATA TD-4300 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

342 HP

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

Pump Performance Curve for TD-4300 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

213 HP

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

0%

10%

20%

30%

40%

50%

60%

70%

BPD

100 200 300 400 500 600 700 800 900 1000 1100M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 69: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-38 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TD-4300 50 HZ

Pump Performance Curve for TD-4300 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

5-1/2 IN139.7 MM

4 IN 7/8 IN101.60MM 22.22MM

60 HZ 50 HZ

8000 PSI 522 HP 435 HP

5000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

0

1

2

3

4

5

M

5

10

15

Ft

Head

0 100 200 300 400 500 600 700 800 900 1000

0%

15%

30%

45%

60%

75%

M3/DAY

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.5

1.0

1.5

2.0

2.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 70: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 4 130391 4 130741 4 132541 4 1325612 3.5 1.07 74 33.6 6 130392 8 130742 8 132542 8 1325623 4.9 1.49 105 47.6 13 130393 13 130743 13 132543 13 1325634 6.3 1.92 135 61.2 18 130394 17 130744 17 132544 17 1325645 7.8 2.38 166 75.3 22 130395 22 130745 22 132545 22 1325656 9.2 2.80 196 88.9 27 130396 26 130746 27 132546 26 1325667 10.6 3.23 226 102.5 31 130397 31 130747 31 132547 31 1325678 12 3.66 257 116.6 36 130398 35 130748 36 132548 35 1325689 13.4 4.08 287 130.2 40 130399 40 130749 40 132549 40 13256910 14.8 4.51 318 144.2 45 130400 45 130750 45 132550 45 13257011 16.2 4.94 348 157.8 49 130401 49 130751 49 132551 49 13257112 17.6 5.36 378 171.5 54 130402 54 130752 54 132552 54 13257213 19 5.79 408 185.1 59 130403 58 130753 59 132553 58 13257314 20.4 6.22 438 198.7 63 130404 63 130754 63 132554 63 13257415 21.8 6.64 468 212.3 68 130405 68 130755 68 132555 68 132575

Feet Meters Lbs. Kgs.Bolt on Head (2 7/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-39

TD-4300 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

132160

120557934026934026

Page 71: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-40 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-4300 1 stage, S.G. = 1

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 1000 2000 3000 4000 5000 6000 7000 8000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD250 500 750 1000 1250M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 72: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

78 HP

Pump Performance Curve for TD-460 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

ENGINEERING DATA TD-460 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

125 HP

0

5

10

15

20

25

30

35

Ft

2

4

6

8

10

MHead

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700

0%

10%

20%

30%

40%

50%

60%

70%

BPD

10 20 30 40 50 60 70 80 90 100 110M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 73: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-10 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 192 HP 160 HP

5000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

5/8 IN101.60MM 15.88MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-460 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-460 50 HZ

0

2

4

6

8

10

12

M

5

10

15

20

25

30

35

40

Ft

Head

0 10 20 30 40 50 60 70 80 90 100

0%

10%

20%

30%

40%

50%

60%

M3/DAY

50 100 150 200 250 300 350 400 450 500 550 600BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.1

0.2

0.2

0.3

0.3

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 74: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 16 160401 15 160381 15 160551 14 1605712 3.5 1.07 74 33.6 34 160402 33 160382 32 160552 31 1605723 4.9 1.49 105 47.6 52 160403 50 160383 48 160553 47 1605734 6.3 1.92 135 61.2 69 160404 68 160384 65 160554 64 1605745 7.8 2.38 166 75.3 87 160405 86 160385 81 160555 79 1605756 9.2 2.80 196 88.9 105 160406 100 160386 97 160556 95 1605767 10.6 3.23 226 102.5 123 160407 113 1605578 12 3.66 257 116.6 140 160408 129 1605589 13.4 4.08 287 130.2 158 160409 146 16055910 14.8 4.51 318 144.2 176 160410 162 16056011 16.2 4.94 348 157.9 194 160411 179 16056112 17.6 5.36 378 171.5 211 160412 195 160562

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.23 0.07 1.07 0.5Pump to Pump Coupling - FLT 0.19 0.06 0.65 0.3Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120555926477

934281 934291

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-460 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 75: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-12 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-460 1 stage, S.G. = 1

0

10

20

30

40

50

60

Ft

4

8

12

16

20

MHead

0 100 200 300 400 500 600 700 800 900

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD25 50 75 100 125M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 76: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-41

ENGINEERING DATA TD-6000 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

342 HP

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

Pump Performance Curve for TD-6000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

213 HP

0

5

10

15

20

25

Ft

2

4

6

8

MHead

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

0%

20%

40%

60%

80%

100%

BPD

250 500 750 1000 1250M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

4.0

5.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 77: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 101.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-42 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TD-6000 50 HZ

Pump Performance Curve for TD-6000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

5-1/2 IN139.7 MM

4 IN 7/8 IN101.60MM 22.22MM

60 HZ 50 HZ

8000 PSI 522 HP 435 HP

5000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

0

1

2

3

4

5

6

M

5

10

15

20

Ft

Head

0 250 500 750 1000 1250

0%

13%

25%

38%

50%

63%

75%

M3/DAY

1000 2000 3000 4000 5000 6000 7000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.3

0.5

0.8

1.0

1.3

1.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 78: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 4 131901 4 131921 4 132581 4 1326012 3.5 1.07 74 33.6 8 131902 8 131922 8 132582 8 1326023 4.9 1.49 105 47.6 13 131903 13 131923 13 132583 13 1326034 6.3 1.92 135 61.2 17 131904 17 131924 17 132584 17 1326045 7.8 2.38 166 75.3 22 131905 22 131925 22 132585 22 1326056 9.2 2.80 196 88.9 27 131906 26 131926 27 132586 26 1326067 10.6 3.23 226 102.5 31 131907 31 131927 31 132587 31 1326078 12 3.66 257 116.6 36 131908 35 131928 36 132588 35 1326089 13.4 4.08 287 130.2 40 131909 40 131929 40 132589 40 13260910 14.8 4.51 318 144.2 45 131910 45 131930 45 132590 45 13261011 16.2 4.94 348 157.8 49 131911 49 131931 49 132591 49 13261112 17.6 5.36 378 171.5 54 131912 54 131932 54 132592 54 13261213 19 5.79 408 185.1 59 131913 58 131933 59 132593 58 13261314 20.4 6.22 438 198.7 63 131914 63 131934 63 132594 63 13261415 21.8 6.64 468 212.3 68 131915 68 131935 68 132595 68 132615

Feet Meters Lbs. Kgs.Bolt on Head (2 7/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-43

TD-6000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

132160

120557934026934026

Page 79: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-44 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-6000 1 stage, S.G. = 1

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 2000 4000 6000 8000 10000 12000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD500 1000 1500M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 80: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

78 HP

Pump Performance Curve for TD-650 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

ENGINEERING DATA TD-650 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

125 HP

0

5

10

15

20

25

30

Ft

2

4

6

8

MHead

0 100 200 300 400 500 600 700 800 900 1000 1100 1200

0%

10%

20%

30%

40%

50%

60%

BPD

25 50 75 100 125 150 175M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

0.6

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 81: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-14 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

8000 PSI 192 HP 160 HP

5000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

5/8 IN101.60MM 15.88MM

60 HZ

5-1/2 IN139.7 MM

4 IN

Pump Performance Curve for TD-650 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TD-650 50 HZ

0

1

2

3

4

5

6

7

M

5

10

15

20

Ft

Head

0 25 50 75 100 125 150

0%

10%

20%

30%

40%

50%

60%

70%

M3/DAY

100 200 300 400 500 600 700 800 900 1000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 82: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 18 131141 15 130111 17 118081 14 1301212 3.5 1.07 74 33.6 37 131142 33 130112 35 118082 31 1301223 4.9 1.49 105 47.6 56 131143 50 130113 52 118083 47 1301234 6.3 1.92 135 61.2 76 131144 68 130114 71 118084 64 1301245 7.8 2.38 166 75.3 95 131145 86 130115 88 118085 79 1301256 9.2 2.80 196 88.9 114 131146 100 130116 105 118086 91 1301267 10.6 3.23 226 102.5 133 131147 123 1180878 12 3.66 257 116.6 153 131148 141 1180889 13.4 4.08 287 130.2 172 131149 158 11808910 14.8 4.51 318 144.2 191 131150 176 11809011 16.2 4.94 348 157.9 210 131151 193 11809112 17.6 5.36 378 171.5 230 131152 211 118092

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.23 0.07 1.07 0.5Pump to Pump Coupling - FLT 0.19 0.06 0.65 0.3Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120555926477934281

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TD-650 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 83: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-16 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-650 1 stage, S.G. = 1

0

10

20

30

40

50

60

Ft

4

8

12

16

20

MHead

0 200 400 600 800 1000 1200 1400

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD50 100 150 200M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 84: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17

ENGINEERING DATA TD-850 60 HZ

139.7 MM5-1/2 IN

8000 PSI6000 PSI5000 PSI

101.60MM4 IN

125 HP

50 HZ60 HZ

5/8 IN15.88MM

94 HP150 HP192 HP 160 HP

Pump Performance Curve for TD-850 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

78 HP

0

5

10

15

20

25

30

Ft

2

4

6

8

MHead

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500

0%

10%

20%

30%

40%

50%

60%

BPD

25 50 75 100 125 150 175 200 225M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.2

0.3

0.4

0.5

0.6

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 85: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 4” / 102 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-18 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TD-850 50 HZ

Pump Performance Curve for TD-850 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

5-1/2 IN139.7 MM

4 IN 5/8 IN101.60MM 15.88MM

60 HZ 50 HZ

8000 PSI 192 HP 160 HP

5000 PSI 94 HP 78 HP6000 PSI 150 HP 125 HP

0

1

2

3

4

5

6

7

M

5

10

15

20

Ft

Head

0 25 50 75 100 125 150 175

0%

10%

20%

30%

40%

50%

60%

70%

M3/DAY

100 200 300 400 500 600 700 800 900 1000 1100BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.1

0.3

0.4

0.5

0.6

0.8

0.9

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 86: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 16 123501 15 130591 15 123521 14 1306012 3.5 1.07 74 33.6 34 123502 33 130592 32 123522 31 1306023 4.9 1.49 105 47.6 52 123503 50 130593 48 123523 47 1306034 6.3 1.92 135 61.2 69 123504 68 130594 65 123524 64 1306045 7.8 2.38 166 75.3 87 123505 86 130595 81 123525 79 1306056 9.2 2.80 196 88.9 105 123506 100 130596 97 123526 91 1306067 10.6 3.23 226 102.5 123 123507 113 1235278 12 3.66 257 116.6 140 123508 129 1235289 13.4 4.08 287 130.2 158 123509 145 12352910 14.8 4.51 318 144.2 176 123510 162 12353011 16.2 4.94 348 157.9 194 123511 178 12353112 17.6 5.36 378 171.5 211 123512 194 123532

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.6 0.18 10 4.5Coupling for Intake or GS 0.23 0.07 1.07 0.5Pump to Pump Coupling - FLT 0.19 0.06 0.65 0.3Pump to Pump Coupling - CMP 0.22 0.07 0.65 0.3

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19

TD-850 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120555926477934281

Page 87: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-20 Product Catalog - Pump Curves 400 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TD-850 1 stage, S.G. = 1

0

10

20

30

40

50

60

Ft

4

8

12

16

20

MHead

0 200 400 600 800 1000 1200 1400 1600

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD50 100 150 200 250M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 88: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.125” / 130.2 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

313 HP

Pump Performance Curve for TG-4000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1 IN25.40MM

375 HP600 HP765 HP 638 HP

ENGINEERING DATA TG-4000 60 HZ

168.3 MM6-5/8 IN

6000 PSI6000 PSI5000 PSI

130.18MM5.13 IN

500 HP

0

10

20

30

40

50

60

Ft

4

8

12

16

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500

0%

10%

20%

30%

40%

50%

60%

BPD

100 200 300 400 500 600 700 800 900 1000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

4.0

5.0

6.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 89: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.125” / 130.2 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

6000 PSI 765 HP 638 HP

5000 PSI 375 HP 313 HP6000 PSI 600 HP 500 HP

1 IN130.18MM 25.40MM

60 HZ

6-5/8 IN168.3 MM

5.13 IN

Pump Performance Curve for TG-4000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TG-4000 50 HZ

0

2

4

6

8

10

12

M

5

10

15

20

25

30

35

40

Ft

Head

0 100 200 300 400 500 600 700 800 900

0%

10%

20%

30%

40%

50%

60%

M3/DAY

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

0.5

1.0

1.5

2.0

2.5

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 90: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 77 34.9 5 184021 5 131161 5 111461 5 1312212 3.5 1.07 145 65.8 12 184022 11 131162 12 111462 11 1312223 4.9 1.49 213 96.6 18 184023 18 131163 18 111463 18 1312234 6.3 1.92 272 123.4 25 184024 25 131164 25 1312245 7.8 2.38 340 154.2 32 184025 32 131165 32 111465 32 1312256 9.2 2.80 407 184.6 39 184026 38 131166 39 111466 38 1312267 10.6 3.23 467 211.8 46 184027 45 131167 46 111467 45 1312278 12 3.66 535 242.7 52 184028 52 131168 52 111468 52 1312289 13.4 4.08 602 273.1 59 184029 59 131169 59 111469 59 13122910 14.8 4.51 662 300.3 66 184030 65 131170 66 111470 65 13123011 16.2 4.94 730 331.1 73 184031 73 131171 73 111471 73 13123112 17.6 5.36 789 357.9 79 184032 79 131172 79 111472 79 13123213 19 5.79 857 388.7 86 184033 86 131173 86 111473 86 13123314 20.4 6.22 924 419.1 93 184034 92 131174 93 111474 92 13123415 21.8 6.64 984 446.3 100 184035 100 131175 100 111475 100 131235

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 12 5.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 0.85 0.4Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

1232701011709949651

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TG-4000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 91: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 513 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TG-4000 1 stage, S.G. = 1

0

20

40

60

80

100

Ft

5

10

15

20

25

30

35

MHead

0 1000 2000 3000 4000 5000 6000 7000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD250 500 750 1000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 92: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-29

ENGINEERING DATA TE-11000 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

849 HP

50 HZ60 HZ

1-11/1642.86MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TE-11000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

10

20

30

40

50

Ft

4

8

12

16

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000

0%

15%

30%

45%

60%

75%

BPD

500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.0

4.0

6.0

8.0

10.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 93: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-30 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-11000 50 HZ

Pump Performance Curve for TE-11000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 1-11/16136.55MM 42.86MM

60 HZ 50 HZ

6000 PSI 1300 HP 1083 HP

6000 PSI 637 HP 531 HP6000 PSI 1019 HP 849 HP

0

5

10

M

10

20

30

40

Ft

Head

0 250 500 750 1000 1250 1500 1750 2000

0%

25%

50%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 94: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 116 52.6 3 138171 3 138191 3 138211 3 1382312 4 1.22 186 84.4 7 138172 7 138192 7 138212 7 1382323 5.5 1.68 245 111.1 10 138173 10 138193 10 138213 10 1382334 7 2.13 314 142.4 14 138174 14 138194 14 138214 14 1382345 8.5 2.59 384 174.2 18 138175 18 138195 18 138215 18 1382356 10 3.05 453 205.5 22 138176 22 138196 22 138216 22 1382367 11.5 3.51 523 237.2 26 138177 26 138197 26 138217 26 1382378 13 3.96 582 264.0 29 138178 29 138198 29 138218 29 1382389 14.5 4.42 652 295.7 33 138179 33 138199 33 138219 33 13823910 16 4.88 721 327.0 37 138180 37 138200 37 138220 37 13824011 17.5 5.33 791 358.8 41 138181 41 138201 41 138221 41 13824112 19 5.79 850 385.6 44 138182 44 138202 44 138222 44 13824213 20.5 6.25 920 417.3 48 138183 48 138203 48 138223 48 13824314 22 6.71 989 448.6 52 138184 52 138204 52 138224 52 13824415 23.5 7.16 1059 480.4 56 138185 56 138205 56 138225 56 138245

Feet Meters Lbs. Kgs.Bolt on Head (3 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.5 0.7Pump to Pump Coupling - FLT 0.2 0.06 1.69 0.8Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-31

TE-11000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

952572952572123247

Page 95: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-32 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-11000 1 stage, S.G. = 1

0

20

40

60

80

100

Ft

5

10

15

20

25

30

35

MHead

0 5000 10000 15000 20000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 96: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

ENGINEERING DATA TE-1500 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

342 HP

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

Pump Performance Curve for TE-1500 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

213 HP

0

20

40

60

Ft

5

10

15

20

MHead

0 400 800 1200 1600 2000 2400 2800

0%

20%

40%

60%

Efficiency

Power

BPD

100 200 300 400M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

CAPACITY

Page 97: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-1500 50 HZ

Pump Performance Curve for TE-1500 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 7/8 IN136.55MM 22.22MM

60 HZ 50 HZ

6000 PSI 522 HP 435 HP

6000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 50 100 150 200 250 300 350

0%

20%

40%

60%

M3/DAY

250 500 750 1000 1250 1500 1750 2000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 98: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 117 53.1 7 138631 7 138461 7 138671 7 1386912 4 1.22 178 80.7 14 138632 14 138462 14 138672 14 1386923 5.5 1.68 245 111.1 22 138633 22 138463 22 138673 22 1386934 7 2.13 312 141.5 30 138634 30 138464 30 138674 30 1386945 8.5 2.59 373 169.2 37 138635 37 138465 37 138675 37 1386956 10 3.05 440 199.6 45 138636 45 138466 45 138676 45 1386967 11.5 3.51 502 227.7 52 138637 52 138467 52 138677 52 1386978 13 3.96 569 258.1 60 138638 60 138468 60 138678 60 1386989 14.5 4.42 635 288.0 68 138639 68 138469 68 138679 68 13869910 16 4.88 697 316.2 78 138640 75 138470 75 138680 75 13870011 17.5 5.33 764 346.5 83 138641 83 138471 83 138681 83 13870112 19 5.79 825 374.2 90 138642 90 138472 90 138682 90 13870213 20.5 6.25 892 404.6 98 138643 98 138473 98 138683 98 13870314 22 6.71 959 435.0 106 138644 106 13868415 23.5 7.16 1021 463.1 113 138645 113 138685

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 12 5.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 0.85 0.4Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

TE-1500 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

120557120557949388

Page 99: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-1500 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

Ft

5

10

15

20

25

30

35

40

45MHead

0 500 1000 1500 2000 2500 3000 3500 4000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300 400 500 600M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 100: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

ENGINEERING DATA TE-2700 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

342 HP

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

Pump Performance Curve for TE-2700 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

213 HP

0

20

40

60

Ft

5

10

15

20

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500

0%

20%

40%

60%

Power

BPD

100 200 300 400 500 600 700M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

CAPACITY

Page 101: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-2700 50 HZ

Pump Performance Curve for TE-2700 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 7/8 IN136.55MM 22.22MM

60 HZ 50 HZ

6000 PSI 522 HP 435 HP

6000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 50 100 150 200 250 300 350 400 450 500 550 600

0%

20%

40%

60%

M3/DAY

250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 102: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 117 53.1 7 138761 7 138741 7 138821 7 1388012 4 1.22 178 80.7 14 138762 14 138742 14 138822 14 1388023 5.5 1.68 245 111.1 22 138763 22 138743 22 138823 22 1388034 7 2.13 312 141.5 30 138764 30 138744 30 138824 30 1388045 8.5 2.59 373 169.2 37 138765 37 138745 37 138825 37 1388056 10 3.05 440 199.6 45 138766 45 138746 45 138826 45 1388067 11.5 3.51 502 227.7 52 138767 52 138747 52 138827 52 1388078 13 3.96 569 258.1 60 138768 60 138748 60 138828 60 1388089 14.5 4.42 635 288.0 68 138769 68 138749 68 138829 68 13880910 16 4.88 697 316.2 75 138770 75 138750 75 138830 75 13881011 17.5 5.33 764 346.5 83 138771 83 138751 83 138831 83 13881112 19 5.79 825 374.2 90 138772 90 138752 90 138832 90 13881213 20.5 6.25 892 404.6 98 138773 98 138753 98 138833 98 13881314 22 6.71 959 435.0 106 138774 106 13883415 23.5 7.16 1021 463.1 113 138775 113 138835

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

TE-2700 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

120557120557949388

Page 103: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-8 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-2700 1 stage, S.G. = 1

0

20

40

60

80

100

120

Ft

5

10

15

20

25

30

35

40

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD100 200 300 400 500 600 700M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 104: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

ENGINEERING DATA TE-3300 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

342 HP

50 HZ60 HZ

7/8 IN22.22MM

256 HP410 HP522 HP 435 HP

Pump Performance Curve for TE-3300 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

213 HP

0

10

20

30

40

50

60

70

Ft

4

8

12

16

20

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

0%

10%

20%

30%

40%

50%

60%

70%

Power

BPD

100 200 300 400 500 600 700 800 900M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

CAPACITY

Page 105: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-10 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-3300 50 HZ

Pump Performance Curve for TE-3300 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 7/8 IN136.55MM 22.22MM

60 HZ 50 HZ

6000 PSI 522 HP 435 HP

6000 PSI 256 HP 213 HP6000 PSI 410 HP 342 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 100 200 300 400 500 600 700 800

0%

20%

40%

60%

M3/DAY

500 1000 1500 2000 2500 3000 3500 4000 4500 5000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 106: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 117 53.1 7 158481 7 158061 7 158501 7 1585212 4 1.22 178 80.7 14 158482 14 158062 14 158502 14 1585223 5.5 1.68 245 111.1 22 158483 22 158063 22 158503 22 1585234 7 2.13 312 141.5 30 158484 30 158064 30 158504 30 1585245 8.5 2.59 373 169.2 37 158485 37 158065 37 158505 37 1585256 10 3.05 440 199.6 45 158486 45 158066 45 158506 45 1585267 11.5 3.51 502 227.7 52 158487 52 158067 52 158507 52 1585278 13 3.96 569 258.1 60 158488 60 158068 60 158508 60 1585289 14.5 4.42 635 288.0 68 158489 68 158069 68 158509 68 15852910 16 4.88 697 316.2 75 158490 75 158070 75 158510 75 15853011 17.5 5.33 764 346.5 83 158491 83 158071 83 158511 83 15853112 19 5.79 825 374.2 90 158492 90 158072 90 158512 90 15853213 20.5 6.25 892 404.6 98 158493 98 158073 98 158513 98 15853314 22 6.71 959 435.0 106 158494 106 15851415 23.5 7.16 1021 463.1 113 158495 113 158515

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

TE-3300 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

120557120577138028

Page 107: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-12 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-3300 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

Ft

5

10

15

20

25

30

35

40

45

MHead

0 1000 2000 3000 4000 5000 6000 7000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD250 500 750 1000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 108: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

ENGINEERING DATA TE-4200 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

500 HP

50 HZ60 HZ

1 IN25.40MM

375 HP600 HP765 HP 638 HP

Pump Performance Curve for TE-4200 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

313 HP

0

10

20

30

40

50

60

70

Ft

4

8

12

16

20

MHead

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500

0%

10%

20%

30%

40%

50%

60%

70%

Power

BPD

100 200 300 400 500 600 700 800 900 1000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

CAPACITY

Page 109: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-14 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-4200 50 HZ

Pump Performance Curve for TE-4200 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 1 IN136.55MM 25.40MM

60 HZ 50 HZ

6000 PSI 765 HP 638 HP

6000 PSI 375 HP 313 HP6000 PSI 600 HP 500 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 100 200 300 400 500 600 700 800 900

0%

20%

40%

60%

M3/DAY

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

1.0

2.0

3.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 110: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 115 52.2 5 158651 5 158631 5 158821 5 1586712 4 1.22 180 81.6 11 158652 11 158632 11 158822 11 1586723 5.5 1.68 245 111.1 17 158653 17 158633 17 158823 17 1586734 7 2.13 311 141.1 23 158654 23 158634 23 158824 23 1586745 8.5 2.59 376 170.6 29 158655 29 158635 29 158825 29 1586756 10 3.05 441 200.0 35 158656 35 158636 35 158826 35 1586767 11.5 3.51 507 230.0 41 158657 41 158637 41 158827 41 1586778 13 3.96 572 259.5 47 158658 47 158638 47 158828 47 1586789 14.5 4.42 637 288.9 53 158659 53 158639 53 158829 53 15867910 16 4.88 703 318.9 59 158660 59 158640 59 158830 59 15868011 17.5 5.33 768 348.4 65 158661 65 158641 65 158831 65 15868112 19 5.79 833 377.8 71 158662 71 158642 71 158832 71 15868213 20.5 6.25 899 407.8 77 158663 77 158643 77 158833 77 15868314 22 6.71 964 437.3 83 158664 83 158644 83 158834 83 15868415 23.5 7.16 1029 466.7 89 158665 89 158645 89 158835 89 158685

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15

TE-4200 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

123270123270138028

Page 111: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-16 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-4200 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

Ft

5

10

15

20

25

30

35

40

45

MHead

0 1000 2000 3000 4000 5000 6000 7000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD250 500 750 1000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 112: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17

313 HP

Pump Performance Curve for TE-5500 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1 IN25.40MM

375 HP600 HP765 HP 638 HP

ENGINEERING DATA TE-4200 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

500 HP

0

20

40

60

80

Ft

5

10

15

20

25

MHead

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000

0%

20%

40%

60%

80%

Power

BPD

250 500 750 1000 1250 1500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.0

4.0

6.0

8.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

CAPACITY

Page 113: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-18 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

6000 PSI 765 HP 638 HP

6000 PSI 375 HP 313 HP6000 PSI 600 HP 500 HP

1 IN136.55MM 25.44MM

60 HZ

7 IN177.8 MM

5-3/8 IN

Pump Performance Curve for TE-5500 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TE-4200 50 HZ

0

5

10

M

10

20

30

40

Ft

Head

0 250 500 750 1000 1250

0%

25%

50%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 114: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 115 52.2 5 138351 5 138331 5 138371 5 1383912 4 1.22 180 81.6 11 138352 11 138332 11 138372 11 1383923 5.5 1.68 245 111.1 17 138353 17 138333 17 138373 17 1383934 7 2.13 311 141.1 23 138354 23 138334 23 138374 23 1383945 8.5 2.59 376 170.6 29 138355 29 138335 29 138375 29 1383956 10 3.05 441 200.0 35 138356 35 138336 35 138376 35 1383967 11.5 3.51 507 230.0 41 138357 41 138337 41 138377 41 1383978 13 3.96 572 259.5 47 138358 47 138338 47 138378 47 1383989 14.5 4.42 637 288.9 53 138359 53 138339 53 138379 53 13839910 16 4.88 703 318.9 59 138360 59 138340 59 138380 59 13840011 17.5 5.33 768 348.4 65 138361 65 138341 65 138381 65 13840112 19 5.79 833 377.8 71 138362 71 138342 71 138382 71 13840213 20.5 6.25 899 407.8 77 138363 77 138343 77 138383 77 13840314 22 6.71 964 437.3 83 138364 83 138344 83 138384 83 13840415 23.5 7.16 1029 466.7 89 138365 89 138345 89 138385 89 138405

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

123270123270949651

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TE-5500 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 115: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-20 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-5500 1 stage, S.G. = 1

0

20

40

60

80

100

120

Ft

5

10

15

20

25

30

35

40

MHead

0 2000 4000 6000 8000 10000 12000 14000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD500 1000 1500 2000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 116: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-21

ENGINEERING DATA TE-7000 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

500 HP

50 HZ60 HZ

1 IN25.40MM

375 HP600 HP765 HP 638 HP

Pump Performance Curve for TE-7000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

313 HP

0

20

40

60

80

Ft

5

10

15

20

25

MHead

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000

0%

20%

40%

60%

80%

BPD

250 500 750 1000 1250 1500 1750M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.0

4.0

6.0

8.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 117: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-22 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TE-7000 50 HZ

Pump Performance Curve for TE-7000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-3/8 IN 1 IN136.55MM 25.40MM

60 HZ 50 HZ

6000 PSI 765 HP 638 HP

6000 PSI 375 HP 313 HP6000 PSI 600 HP 500 HP

0

5

10

M

10

20

30

40

Ft

Head

0 250 500 750 1000 1250 1500

0%

25%

50%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 118: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 115 52.2 5 138271 5 138111 5 138291 5 1383112 4 1.22 180 81.6 11 138272 11 138112 11 138292 11 1383123 5.5 1.68 245 111.1 17 138273 17 138113 17 138293 17 1383134 7 2.13 311 141.1 23 138274 23 138114 23 138294 23 1383145 8.5 2.59 376 170.6 29 138275 29 138115 29 138295 29 1383156 10 3.05 441 200.0 35 138276 35 138116 35 138296 35 1383167 11.5 3.51 507 230.0 41 138277 41 138117 41 138297 41 1383178 13 3.96 572 259.5 47 138278 47 138118 47 138298 47 1383189 14.5 4.42 637 288.9 53 138279 53 138119 53 138299 53 13831910 16 4.88 703 318.9 59 138280 59 138120 59 138300 59 13832011 17.5 5.33 768 348.4 65 138281 65 138121 65 138301 65 13832112 19 5.79 833 377.8 71 138282 71 138122 71 138302 71 13832213 20.5 6.25 899 407.8 77 138283 77 138123 77 138303 77 13832314 22 6.71 964 437.3 83 138284 83 138124 83 138304 83 13832415 23.5 7.16 1029 466.7 89 138285 89 138125 89 138305 89 138325

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-23

TE-7000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

123270123270949651

Page 119: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-24 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-7000 1 stage, S.G. = 1

0

20

40

60

80

100

120

Ft

5

10

15

20

25

30

35

40

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 120: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-25

313 HP

Pump Performance Curve for TE-7200 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1 IN25.40MM

375 HP600 HP765 HP 638 HP

ENGINEERING DATA TE-7200 60 HZ

177.8 MM7 IN

6000 PSI6000 PSI6000 PSI

136.55MM5-3/8 IN

500 HP

0

20

40

60

80

Ft

5

10

15

20

25

MHead

0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000

0%

20%

40%

60%

80%

BPD

250 500 750 1000 1250 1500 1750M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.0

4.0

6.0

8.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 121: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.375” / 136.6 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-26 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

6000 PSI 765 HP 638 HP

6000 PSI 375 HP 313 HP6000 PSI 600 HP 500 HP

1 IN136.55MM 25.40MM

60 HZ

7 IN177.8 MM

5-3/8 IN

Pump Performance Curve for TE-7200 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TE-7200 50 HZ

0

5

10

M

10

20

30

40

Ft

Head

0 250 500 750 1000 1250 1500

0%

25%

50%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 122: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.5 0.76 115 52.2 5 158771 5 158721 5 158791 5 1587412 4 1.22 180 81.6 11 158772 11 158722 11 158792 11 1587423 5.5 1.68 245 111.1 17 158773 17 158723 17 158793 17 1587434 7 2.13 311 141.1 23 158774 23 158724 23 158794 23 1587445 8.5 2.59 376 170.6 29 158775 29 158725 29 158795 29 1587456 10 3.05 441 200.0 35 158776 35 158726 35 158796 35 1587467 11.5 3.51 507 230.0 41 158777 41 158727 41 158797 41 1587478 13 3.96 572 259.5 47 158778 47 158728 47 158798 47 1587489 14.5 4.42 637 288.9 53 158779 53 158729 53 158799 53 15874910 16 4.88 703 318.9 59 158780 59 158730 59 158800 59 15875011 17.5 5.33 768 348.4 65 158781 65 158731 65 158801 65 15875112 19 5.79 833 377.8 71 158782 71 158732 71 158802 71 15875213 20.5 6.25 899 407.8 77 158783 77 158733 77 158803 77 15875314 22 6.71 964 437.3 83 158784 83 158734 83 158804 83 15875415 23.5 7.16 1029 466.7 89 158785 89 158735 89 158805 89 158755

Feet Meters Lbs. Kgs.Bolt on Head (3-1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.22 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.2 0.5Pump to Pump Coupling - CMP 0.21 0.06 1.2 0.5

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-27

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

940510

123270123270949651

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TE-7200 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 123: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-28 Product Catalog - Pump Curves 538 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TE-7200 1 stage, S.G. = 1

0

20

40

60

80

100

120

Ft

5

10

15

20

25

30

35

40

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 124: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.625” / 142.9 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

ENGINEERING DATA TH-15000 60 HZ

177.8 MM7 IN

3600 PSI3600 PSI3000 PSI

142.88MM5-5/8 IN

849 HP

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TH-15000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

5

10

15

20

25

30

35

40

45

50

Ft

2

4

6

8

10

12

14

16

18

20

MHead

0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000

0%

5%

10%

15%

20%

25%

30%

35%

40%

45%

50%

BPD

500 1000 1500 2000 2500 3000 3500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

18.0

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 125: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.625” / 142.9 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TH-15000 50 HZ

Pump Performance Curve for TH-15000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-5/8 IN 1-3/16 IN142.88MM 30.16MM

60 HZ 50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 500 1000 1500 2000 2500 3000 3500

0%

25%

50%

75%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 126: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 108 49.0 2 1232512 3.5 1.07 174 78.9 5 123252 5 1233723 4.9 1.49 241 109.3 8 123253 8 1233734 6.3 1.92 307 139.2 11 123254 11 1233745 7.7 2.35 374 169.6 14 123255 14 1233756 9.1 2.77 440 199.5 17 123256 17 1233767 10.5 3.20 506 229.5 20 123257 20 1233778 11.9 3.63 573 259.9 23 123258 23 1233789 13.3 4.05 639 289.8 26 123259 26 12337910 14.7 4.48 706 320.2 29 123260 29 12338011 16.1 4.91 772 350.1 32 123261 32 12338112 17.5 5.33 839 380.5 36 123262 36 12338213 18.9 5.76 905 410.4 39 123263 39 12338314 20.3 6.19 994 450.8 42 123264 42 123384

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.5 0.7Pump to Pump Coupling - FLT 0.2 0.06 1.69 0.8Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

TH-15000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

123189

123270123270949651

Page 127: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-8 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TH-15000 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

Ft

5

10

15

20

25

30

35

40

45MHead

0 5000 10000 15000 20000 25000 30000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 128: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.625” / 142.9 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

ENGINEERING DATA TH-20000 60 HZ

177.8 MM7 IN

3600 PSI3600 PSI3000 PSI

142.88MM5-5/8 IN

849 HP

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TH-20000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

5

10

15

20

25

30

35

40

45

50

Ft

2

4

6

8

10

12

14

16

18

20

MHead

0 2500 5000 7500 10000 12500 15000 17500 20000 22500 25000 27500 30000

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

BPD

500 1000 1500 2000 2500 3000 3500 4000 4500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

7.5

10.0

12.5

15.0

17.5

20.0

22.5

25.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 129: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 5.625” / 142.9 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-10 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TH-20000 50 HZ

Pump Performance Curve for TH-20000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

7 IN177.8 MM

5-5/8 IN 1-3/16 IN142.88MM 30.16MM

60 HZ 50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 500 1000 1500 2000 2500 3000 3500 4000

0%

25%

50%

75%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000 22500 25000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 130: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 108 49.0 2 123351 2 1233912 3.5 1.07 174 78.9 5 123352 5 1233923 4.9 1.49 241 109.3 8 123353 8 1233934 6.3 1.92 307 139.2 11 123354 11 1233945 7.7 2.35 374 169.6 14 123355 14 1233956 9.1 2.77 440 199.5 17 123356 17 1233967 10.5 3.20 506 229.5 20 123357 20 1233978 11.9 3.63 573 259.9 23 123358 23 1233989 13.3 4.05 639 289.8 26 123359 26 12339910 14.7 4.48 706 320.2 29 123360 29 12340011 16.1 4.91 772 350.1 32 123361 32 12340112 17.5 5.33 839 380.5 36 123362 36 12340213 18.9 5.76 905 410.4 39 123363 39 12340314 20.3 6.19 994 450.8 42 123364 42 123404

Feet Meters Lbs. Kgs.Bolt on Head (3 - 1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.5 0.7Pump to Pump Coupling - FLT 0.2 0.06 1.69 0.8Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

TH-20000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

123189

123270123270949651

Page 131: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-12 Product Catalog - Pump Curves 562 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TH-20000 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

Ft

5

10

15

20

25

30

35

40

45MHead

0 5000 10000 15000 20000 25000 30000 35000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 132: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

531 HP

Pump Performance Curve for TJ-12000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

ENGINEERING DATA TJ-12000 60 HZ

219.1 MM8-5/8 IN

3600 PSI3600 PSI3000 PSI

171.45MM6-3/4 IN

849 HP

0

20

40

60

80

100

Ft

5

10

15

20

25

30

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000

0%

20%

40%

60%

80%

100%

BPD

500 1000 1500 2000 2500 3000 3500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

25.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 133: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-10 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

1-3/16 IN171..45MM 30.16MM

60 HZ

8-5/8 IN219.1 MM

6-3/4 IN

Pump Performance Curve for TJ-12000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TJ-12000 50 HZ

0

5

10

15

20

M

10

20

30

40

50

60

70

Ft

Head

0 500 1000 1500 2000 2500 3000

0%

25%

50%

75%

100%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 134: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.7 0.82 192 87.1 2 117391 2 1180612 4 1.22 286 129.7 5 117392 5 1180623 5.4 1.65 378 171.4 8 117393 8 1180634 6.8 2.07 472 214.1 11 117394 11 1180645 8.2 2.50 566 256.7 14 117395 14 1180656 9.5 2.90 659 298.9 17 117396 17 1180667 10.9 3.32 751 340.5 20 117397 20 1180678 12.3 3.75 845 383.2 23 117398 23 1180689 13.7 4.18 939 425.8 26 117399 26 11806910 15 4.57 1033 468.5 29 117400 29 11807011 16.4 5.00 1125 510.2 32 117401 32 11807112 17.8 5.43 1218 552.4 35 117402 35 11807213 19.2 5.85 1313 595.4 38 117403 38 11807314 20.5 6.25 1406 637.6 41 117404 41 11807415 21.9 6.68 1499 679.8 44 117405 44 118075

Feet Meters Lbs. Kgs.Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

957647

952572952572952572

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TJ-12000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 135: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Product Catalog - Pump Curves 338 Series - Copyright Wood Group ESP, Inc. - February, 2009

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-12 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TJ-12000 1 stage, S.G. = 1

0

50

100

150

200

Ft

10

20

30

40

50

60

MHead

0 5000 10000 15000 20000 25000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 136: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

ENGINEERING DATA TJ-20000 60 HZ

219.1 MM8-5/8 IN

3600 PSI3600 PSI3000 PSI

171.45MM6-3/4 IN

849 HP

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TJ-20000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

20

40

60

80

100

Ft

5

10

15

20

25

30

MHead

0 5000 10000 15000 20000 25000 30000

0%

20%

40%

60%

80%

100%

BPD

1000 2000 3000 4000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

10.0

20.0

30.0

40.0

50.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 137: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-14 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TJ-20000 50 HZ

Pump Performance Curve for TJ-20000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

8-5/8 IN219.1 MM

6-3/4 IN 1-3/16 IN171.45MM 30.16MM

60 HZ 50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

0

5

10

15

20

M

10

20

30

40

50

60

70

Ft

Head

0 500 1000 1500 2000 2500 3000 3500 4000

0%

20%

40%

60%

80%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000 22500 25000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

4.0

8.0

12.0

16.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 138: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.7 0.82 182 82.6 2 147471 2 1475312 4 1.22 263 119.3 5 147472 5 1475323 5.4 1.65 343 155.6 8 147473 8 1475334 6.8 2.07 424 192.3 11 147474 11 1475345 8.2 2.50 504 228.6 14 147475 14 1475356 9.5 2.90 568 257.6 16 147476 16 1475367 10.9 3.32 648 293.9 19 147477 19 1475378 12.3 3.75 729 330.7 22 147478 22 1475389 13.7 4.18 809 367.0 25 147479 25 14753910 15 4.57 890 403.7 28 147480 28 14754011 16.4 5.00 970 440.0 31 147481 31 14754112 17.8 5.43 1050 476.3 34 147482 34 14754213 19.2 5.85 1131 513.0 37 147483 37 14754314 20.5 6.25 1194 541.6 39 147484 39 14754415 21.9 6.68 1275 578.3 42 147485 42 147545

Feet Meters Lbs. Kgs.Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15

TJ-20000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

957647

952572952572952572

Page 139: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-16 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TJ-20000 1 stage, S.G. = 1

0

50

100

150

200

Ft

10

20

30

40

50

60

MHead

0 5000 10000 15000 20000 25000 30000 35000 40000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000 6000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 140: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

531 HP

Pump Performance Curve for TJ-7500 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

ENGINEERING DATA TJ-7500 60 HZ

219.1 MM8-5/8 IN

3600 PSI3600 PSI3000 PSI

171.45MM6-3/4 IN

849 HP

0

10

20

30

40

50

60

70

80

Ft

4

8

12

16

20

24

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000

0%

10%

20%

30%

40%

50%

60%

70%

80%

BPD

500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

7.5

10.0

12.5

15.0

17.5

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 141: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

1-3/16 IN171.45MM 30.16MM

60 HZ

8-5/8 IN219.1 MM

6-3/4 IN

Pump Performance Curve for TJ-7500 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TJ-7500 50 HZ

0

5

10

15

M

10

20

30

40

50

Ft

Head

0 250 500 750 1000 1250 1500 1750 2000

0%

25%

50%

75%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

2.5

5.0

7.5

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 142: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.7 0.82 210 95.2 2 117271 2 1178412 4 1.22 327 148.3 6 117272 6 1178423 5.4 1.65 419 190.0 9 117273 9 1178434 6.8 2.07 511 231.7 12 117274 12 1178445 8.2 2.50 603 273.5 15 117275 15 1178456 9.5 2.90 714 323.8 19 117276 19 1178467 10.9 3.32 806 365.5 22 117277 22 1178478 12.3 3.75 898 407.2 25 117278 25 1178489 13.7 4.18 1009 457.6 29 117279 29 11784910 15 4.57 1104 500.7 32 117280 32 11785011 16.4 5.00 1193 541.0 35 117281 35 11785112 17.8 5.43 1304 591.4 39 117282 39 11785213 19.2 5.85 1396 633.1 42 117283 42 11785314 20.5 6.25 1488 674.8 45 117284 45 11785415 21.9 6.68 1580 716.5 48 117285 48 117855

Feet Meters Lbs. Kgs.Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

957647

952572952572952572

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TJ-7500 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 143: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TJ-7500 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

160

Ft

5

10

15

20

25

30

35

40

45

50

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000 18000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 144: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

531 HP

Pump Performance Curve for TJ-9000 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1-3/16 IN30.16MM

637 HP1019 HP1300 HP 1083 HP

ENGINEERING DATA TJ-9000 60 HZ

219.1 MM8-5/8 IN

3600 PSI3600 PSI3000 PSI

171.45MM6-3/4 IN

849 HP

0

20

40

60

80

100

Ft

5

10

15

20

25

30

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000

0%

20%

40%

60%

80%

100%

BPD

500 1000 1500 2000 2500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

4.0

8.0

12.0

16.0

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 145: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 6.75” / 171.5 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

3600 PSI 1300 HP 1083 HP

3000 PSI 637 HP 531 HP3600 PSI 1019 HP 849 HP

1-3/16 IN171.45MM 30.16MM

60 HZ

8-5/8 IN219.1 MM

6-3/4 IN

Pump Performance Curve for TJ-9000 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TJ-9000 50 HZ

0

5

10

15

20

M

10

20

30

40

50

60

70

Ft

Head

0 250 500 750 1000 1250 1500 1750 2000

0%

25%

50%

75%

100%

M3/DAY

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 146: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.7 0.82 210 95.3 2 117901 2 1472912 4 1.22 328 148.8 6 117902 6 1472923 5.4 1.65 421 191.0 9 117903 9 1472934 6.8 2.07 513 232.7 12 117904 12 1472945 8.2 2.50 606 274.9 15 117905 15 1472956 9.5 2.90 718 325.7 19 117906 19 1472967 10.9 3.32 810 367.4 22 117907 22 1472978 12.3 3.75 903 409.6 25 117908 25 1472989 13.7 4.18 1015 460.4 29 117909 29 14729910 15 4.57 1110 503.5 32 117910 32 14730011 16.4 5.00 1200 544.3 35 117911 35 14730112 17.8 5.43 1312 595.1 39 117912 39 14730213 19.2 5.85 1404 636.9 42 117913 42 14730314 20.5 6.25 1497 679.0 45 117914 45 14730415 21.9 6.68 1590 721.2 48 117915 48 147305

Feet Meters Lbs. Kgs.Bolt on Head (3 -1/2"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

957647

952572952572952572

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TJ-9000 HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Page 147: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-8 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TJ-9000 1 stage, S.G. = 1

0

20

40

60

80

100

120

140

160

Ft

5

10

15

20

25

30

35

40

45

50

MHead

0 5000 10000 15000 20000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

BPD1000 2000 3000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 148: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

ENGINEERING DATA TM-19000A 60 HZ

273.1 MM10-3/4 IN

2400 PSI2400 PSI2000 PSI

219.08MM8-5/8 IN

849 HP

50 HZ60 HZ

1-1/5 IN30.48MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TM-19000A 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

25

50

75

100

125

150

Ft

10

20

30

40

MHead

0 4000 8000 12000 16000 20000 24000 28000 32000 36000

0%

25%

50%

75%

100%

BPD

1000 2000 3000 4000 5000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

10.0

20.0

30.0

40.0

50.0

60.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 149: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TM-19000A 50 HZ

Pump Performance Curve for TM-19000A 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

10-3/4 IN273.1 MM

8-5/8 IN 1-1/5 IN219.08MM 30.48MM

60 HZ 50 HZ

2400 PSI 1300 HP 1083 HP

2000 PSI 637 HP 531 HP2400 PSI 1019 HP 849 HP

0

5

10

15

20

25

30

M

10

20

30

40

50

60

70

80

90

100

Ft

Head

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

0%

13%

25%

38%

50%

63%

75%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000 22500 25000 27500 30000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

25.0

30.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 150: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.12 Exclude3456789101112131415

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

TM-19000A HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

Page 151: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 675 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-4

Variable Frequency Pump Performance Curve for TM-19000A 1 stage, S.G. = 1

0

50

100

150

200

250

Ft

10

20

30

40

50

60

70

80

90MHead

0 5000 10000 15000 20000 25000 30000 35000 40000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000 6000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 152: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

ENGINEERING DATA TM-19000B 60 HZ

273.1 MM10-3/4 IN

2400 PSI2400 PSI2000 PSI

219.08MM8-5/8 IN

849 HP

50 HZ60 HZ

1-1/5 IN30.48MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TM-19000B 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

25

50

75

100

125

Ft

10

20

30

40

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000

0%

25%

50%

75%

100%

BPD

500 1000 1500 2000 2500 3000 3500 4000 4500M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

10.0

20.0

30.0

40.0

50.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 153: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TM-19000B 50 HZ

Pump Performance Curve for TM-19000B 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

10-3/4 IN273.1 MM

8-5/8 IN 1-1/5 IN219.08MM 30.48MM

60 HZ 50 HZ

2400 PSI 1300 HP 1083 HP

2000 PSI 637 HP 531 HP2400 PSI 1019 HP 849 HP

0

5

10

15

20

25

M

10

20

30

40

50

60

70

80

90

Ft

Head

0 500 1000 1500 2000 2500 3000 3500 4000

0%

25%

50%

75%

100%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000 22500 25000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

25.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 154: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.12 Exclude3456789101112131415

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

TM-19000B HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

Page 155: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-6

Variable Frequency Pump Performance Curve for TM-19000B 1 stage, S.G. = 1

0

50

100

150

200

Ft

10

20

30

40

50

60

70

MHead

0 5000 10000 15000 20000 25000 30000 35000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 156: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

ENGINEERING DATA TM-19000C 60 HZ

273.1 MM10-3/4 IN

2400 PSI2400 PSI2000 PSI

219.08MM8-5/8 IN

849 HP

50 HZ60 HZ

1-1/5 IN30.48MM

637 HP1019 HP1300 HP 1083 HP

Pump Performance Curve for TM-19000C 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

531 HP

0

25

50

75

100

Ft

10

20

30

MHead

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000

0%

25%

50%

75%

100%

BPD

500 1000 1500 2000 2500 3000 3500 4000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

10.0

20.0

30.0

40.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 157: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Pump O.D.* 8.62” / 219 mm

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-6 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

ENGINEERING DATA TM-19000C 50 HZ

Pump Performance Curve for TM-19000C 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

10-3/4 IN273.1 MM

8-5/8 IN 1-1/5 IN219.08MM 30.48MM

60 HZ 50 HZ

2400 PSI 1300 HP 1083 HP

2000 PSI 637 HP 531 HP2400 PSI 1019 HP 849 HP

0

5

10

15

20

M

10

20

30

40

50

60

70

Ft

Head

0 500 1000 1500 2000 2500 3000 3500

0%

25%

50%

75%

100%

M3/DAY

2500 5000 7500 10000 12500 15000 17500 20000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

5.0

10.0

15.0

20.0

HPMTR

LOAD

Qmin BEP Qmax

Head

Efficiency

Power

CAPACITY

Page 158: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.12 Exclude3456789101112131415

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.8 0.24 23 10.4Coupling for Intake or GS 0.23 0.07 1.22 0.6Pump to Pump Coupling - FLT 0.2 0.06 1.22 0.6Pump to Pump Coupling - CMP 0.26 0.08 1.69 0.8

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

TM-19000C HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

Page 159: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-8

Variable Frequency Pump Performance Curve for TM-19000C 1 stage, S.G. = 1

0

50

100

150

200

Ft

10

20

30

40

50

60

MHead

0 5000 10000 15000 20000 25000 30000 35000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Page 160: Wood Group ESP Catalogue

Wood Group ESP, Inc.

#VALUE!

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

833 HP

Pump Performance Curve for TN-35000A 1 stage @ 3500 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

50 HZ60 HZ

1-1/2 IN38.09MM

1000 HP1600 HP2040 HP 1700 HP

ENGINEERING DATA TN-35000A 60 HZ

298.5 MM11-3/4 IN

2760 PSI2760 PSI2300 PSI

241.29MM9-1/2 IN

1333 HP

0

25

50

75

100

125

150

175

200

225

Ft

10

20

30

40

50

60

70

MHead

0 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000 60000 65000 70000 75000

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

Head

Power

BPD

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000M3/DAY

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

25.0

50.0

75.0

100.0

125.0

150.0

175.0

200.0

225.0

HPMTR

LOAD

Qmin BEP Qmax

Efficiency

CAPACITY

Pages Page 1

Page 161: Wood Group ESP Catalogue

Wood Group ESP, Inc.

#VALUE!

MINIMUM CASING SIZE ROTATIONAL DIRECTION CCW

HOUSING DIAMETER* SHAFT DIAMETER

HOUSING PRESSURE LIMIT SHAFT POWER LIMITSTANDARD STANDARD

HIGH PRESSURE HIGH STRENGTHULTRA HIGH PRESSURE ULTRA HIGH STRENGTH

*Diameter does not include lockplates

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

50 HZ

2760 PSI 2040 HP 1700 HP

2300 PSI 1000 HP 833 HP2760 PSI 1600 HP 1333 HP

1-1/2 IN241.29MM 38.09MM

60 HZ

11-3/4 IN298.5 MM

9-1/2 IN

Pump Performance Curve for TN-35000A 1 stage @ 2917 RPM, S.G. = 1

These curves represent nominal performance to be used in pump sizing calculations. Actual pump performance will comply with acceptance limits specified in Table 4.1, API representative 11 S2 (Recommended Practice for Submersible Pump Testing -- August 1, 1997)

ENGINEERING DATA TN-35000A 50 HZ

0

5

10

15

20

25

30

35

40

45

M

10

20

30

40

50

60

70

80

90

100

FtHead

0 1000 2000 3000 4000 5000 6000 7000 8000 9000

0%

13%

25%

38%

50%

63%

75%

88%

100%

Head

Efficiency

Power

M3/DAY

5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000BPD

RECOMMENDEDOPERATING RANGE

PMPONLYEFF

0.0

12.5

25.0

37.5

50.0

62.5

75.0

87.5

100.0

112.5

HPMTR

LOAD

Qmin BEP Qmax

CAPACITY

Pages Page 2

Page 162: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Feet Meters Lbs. Kgs. Stgs. Part No. Stgs. Part No. Stgs. Part No. Stgs. Part No.1 2.1 0.64 44 20.0 14 192421 13 192381 13 192391 12 1924112 3.5 1.07 74 33.6 30 192422 29 192382 29 192392 27 1924123 4.9 1.49 105 47.6 47 192423 45 192383 43 192393 41 1924134 6.3 1.92 135 61.2 63 192424 62 192384 58 192394 56 1924145 7.8 2.38 166 75.3 79 192425 78 192385 73 192395 71 1924156 9.2 2.80 196 88.9 95 192426 94 192386 87 192396 87 1924167 10.6 3.23 226 102.5 111 192427 102 1923978 12 3.66 257 116.6 128 192428 117 1923989 13.4 4.08 287 130.2 144 192429 131 19239910 14.8 4.51 318 144.2 160 192430 146 19240011 16.2 4.94 348 157.8 176 192431 161 19240112 17.6 5.36 378 171.5 192 192432 175 192402

Feet Meters Lbs. Kgs.Bolt on Head (2 3/8"-8rd) 0.3 0.09 10 4.5Coupling for Intake or GS 0.21 0.06 0.77 0.3Pump to Pump Coupling - FLT 0.2 0.06 0.5 0.2Pump to Pump Coupling - CMP 0.21 0.06 0.5 0.2

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your

Wood Group ESP representative.

930941

120556934182934232

HsgLength Weight

STANDARD PUMP ABRASION RESISTANT PUMP

Floater Compression

TN-35000A HOUSING DATA

Weight AR PUMPPart No.

STANDARD PUMPPart No.

Floater Compression

Length

Pages Page 3

Page 163: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Variable Frequency Pump Performance Curve for TN-35000A 1 stage, S.G. = 1

0

50

100

150

200

250

300

350

400

Ft

10

20

30

40

50

60

70

80

90

100

MHead

0 10000 20000 30000 40000 50000 60000 70000

45 Hz

50 Hz

55 Hz

60 Hz

65 Hz

70 Hz

75 Hz

80 Hz

85 Hz

BPD1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000M3/DAY

RECOMMENDEDOPERATING RANGE

CAPACITY

Pages Page 4

Page 164: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM19000A 60 HZ HOUSING DIAMETER 8.62 IN. MINIMUM CASING SIZE 10-3/4 IN. SHAFT DIAMETER 1-3/16 IN.

MINIMUM SHAFT AREA 1.1075 IN. SHAFT LIMIT

STANDARD 637 HP HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT

STANDARD 2000 PSI HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 33 STAGES

HIGH STRENGTH 52 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 54 STAGES HOUSING STANDARD 31 STAGES

HIGH PRESSURE 38 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 165: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM19000A 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 47 STAGES

HIGH STRENGTH 75 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 70 STAGES HOUSING STANDARD 45 STAGES

HIGH PRESSURE 54 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 166: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM19000B 60 HZ HOUSING DIAMETER 8.62 IN. MINIMUM CASING SIZE 10-3/4 IN. SHAFT DIAMETER 1-3/16 IN. MINIMUM SHAFT AREA 1.1075 IN. SHAFT LIMIT

STANDARD 637 HP HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 44 STAGES

HIGH STRENGTH 71 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 64 STAGES HOUSING STANDARD 38 STAGES

HIGH PRESSURE 45 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX)18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 167: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM19000B 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 64 STAGES

HIGH STRENGTH 102 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 84 STAGES HOUSING STANDARD 54 STAGES

HIGH PRESSURE 65 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 168: Wood Group ESP Catalogue
Page 169: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM19000C 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 73 STAGES

HIGH STRENGTH 117 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 103 STAGES HOUSING STANDARD 67 STAGES

HIGH PRESSURE 80 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 170: Wood Group ESP Catalogue

Wood Group ESP, Inc.

TM-19000 PUMP

862 Series - Compression Length Weight No. A-Cut B-Cut C-Cut

Hsg Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number 3 3.3 1.01 528 239.4 3 117653 117311 117683 4 3.9 1.19 587 266.2 4 117654 117312 117684 5 4.5 1.37 662 300.2 5 117655 117313 117685 6 5.1 1.55 729 330.6 6 117656 117314 117686 7 5.7 1.74 789 357.8 7 117657 117315 117687 8 6.3 1.92 863 391.4 8 117658 117316 117688 9 6.9 2.10 931 422.2 9 117659 117317 117689 10 7.5 2.29 991 449.4 10 117660 117318 117690 11 8.1 2.47 1058 479.8 11 117661 117319 117691 12 8.7 2.65 1126 510.6 12 117662 117320 117692 13 9.3 2.83 1193 541.0 13 117663 117321 117693 14 9.9 3.02 1260 571.4 14 117664 117322 117694 15 10.6 3.23 1327 601.8 15 117665 117323 117695 16 11.2 3.41 1395 632.6 16 117666 117371 117696 17 11.8 3.60 1466 664.8 17 117667 117372 117697 18 12.4 3.78 1533 695.2 18 117668 117373 117698 19 13.0 3.96 1596 723.8 19 117669 117374 117699 20 13.6 4.15 1664 754.6 20 117670 117200 117700 21 14.2 4.33 1734 786.4 21 117671 117375 117701 22 14.8 4.51 1801 816.8 22 117672 117376 117702 23 15.4 4.69 1866 846.2 23 117673 117377 117703 24 16.0 4.88 1933 876.6 24 117674 117378 117704 25 16.6 5.06 2003 908.4 25 117675 117379 117705 26 17.2 5.24 2071 939.2 26 117676 117380 117706 27 17.8 5.43 2138 969.6 27 117677 117381 117707 28 18.4 5.61 2202 998.6 28 117678 117382 117708 29 19.0 5.79 2272 1030.4 29 117679 117383 117709 30 19.6 5.97 2339 1060.7 30 117680 117384 117710 31 20.2 6.16 2407 1091.6 31 117681 117385 117711 32 20.8 6.34 2474 1122.0 32 117682 117386 117712

Length Weight STANDARD PUMP Feet Meters Lbs. Kgs. Part No.

Bolt on Head (7”-8rd)-LT 0.97 0.30 62 28.1 117786

Coupling for Intake or GS 0.22 0.06 1.22 0.55 952572

Pump to Pump Coupling 0.22 0.06 1.22 0.55 952572

Shim Kit 0.08 0.02 0.06 0.03 131613

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Page 171: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 172: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

Page 173: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 174: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000A 60 HZ HOUSING DIAMETER 8.62 IN. MINIMUM CASING SIZE 10-3/4 IN. SHAFT DIAMETER 1-3/16 IN. MINIMUM SHAFT AREA 1.1075 IN. SHAFT LIMIT

STANDARD 637 HP HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 20 STAGES

HIGH STRENGTH 32 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 55 STAGES HOUSING STANDARD 29 STAGES

HIGH PRESSURE 35 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

Page 175: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000A 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 29 STAGES

HIGH STRENGTH 46 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 71 STAGES HOUSING STANDARD 42 STAGES

HIGH PRESSURE 51 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-12 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 176: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000B 60 HZ HOUSING DIAMETER 8.62 IN. MINIMUM CASING SIZE 10-3/4 IN. SHAFT DIAMETER 1-3/16 IN. MINIMUM SHAFT AREA 1.1075 IN. SHAFT LIMIT

STANDARD 637 HP HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 23 STAGES

HIGH STRENGTH 36 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 65 STAGES HOUSING STANDARD 37 STAGES

HIGH PRESSURE 44 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

Page 177: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000B 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 32 STAGES

HIGH STRENGTH 52 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 84 STAGES HOUSING STANDARD 53 STAGES

HIGH PRESSURE 64 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-14 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 178: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000C 60 HZ HOUSING DIAMETER 8.62 IN. MINIMUM CASING SIZE 10-3/4 IN. SHAFT DIAMETER 1-3/16 IN. MINIMUM SHAFT AREA 1.1075 IN. SHAFT LIMIT

STANDARD 637 HP HIGH STRENGTH 1019 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 31 STAGES

HIGH STRENGTH 49 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 81 STAGES HOUSING STANDARD 46 STAGES

HIGH PRESSURE 55 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-15

Page 179: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TM24000C 50 HZ HOUSING DIAMETER 218.95 MM MINIMUM CASING SIZE 273.05 MM SHAFT DIAMETER 30.175 MM

MINIMUM SHAFT AREA 715.14 MMP

2

SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

HOUSING PRESSURE LIMIT STANDARD 2000 PSI

HIGH PRESSURE 2400 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 45 STAGES

HIGH STRENGTH 71 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 105 STAGES HOUSING STANDARD 67 STAGES

HIGH PRESSURE 80 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** - For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-16 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 180: Wood Group ESP Catalogue

Wood Group ESP, Inc.

TM-24000 PUMP

862 Series - Compression Length Weight No. A-Cut B-Cut C-Cut

Hsg Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number 3 3.3 1.01 528 239.4 3 117473 117503 117533 4 3.9 1.19 587 266.2 4 117474 117504 117534 5 4.5 1.37 662 300.2 5 117475 117505 117535 6 5.1 1.55 729 330.6 6 117476 117506 117536 7 5.7 1.74 789 357.8 7 117477 117507 117537 8 6.3 1.92 863 391.4 8 117478 117508 117538 9 6.9 2.10 931 422.2 9 117479 117509 117539 10 7.5 2.29 991 449.4 10 117480 117510 117540 11 8.1 2.47 1058 479.8 11 117481 117511 117541 12 8.7 2.65 1126 510.6 12 117482 117512 117542 13 9.3 2.83 1193 541.0 13 117483 117513 117543 14 9.9 3.02 1260 571.4 14 117484 117514 117544 15 10.6 3.23 1327 601.8 15 117485 117515 117545 16 11.2 3.41 1395 632.6 16 117486 117516 117546 17 11.8 3.60 1466 664.8 17 117487 117517 117547 18 12.4 3.78 1533 695.2 18 117488 117518 117548 19 13.0 3.96 1596 723.8 19 117427 117519 117549 20 13.6 4.15 1664 754.6 20 117428 117520 117550 21 14.2 4.33 1734 786.4 21 117491 117521 117551 22 14.8 4.51 1801 816.8 22 117492 117522 117552 23 15.4 4.69 1866 846.2 23 117493 117523 117553 24 16.0 4.88 1933 876.6 24 117494 117524 117554 25 16.6 5.06 2003 908.4 25 117495 117525 117555 26 17.2 5.24 2071 939.2 26 117496 117526 117556 27 17.8 5.43 2138 969.6 27 117497 117527 117557 28 18.4 5.61 2202 998.6 28 117498 117528 117558 29 19.0 5.79 2272 1030.4 29 117499 117529 117559 30 19.6 5.97 2339 1060.7 30 117500 117530 117560 31 20.2 6.16 2407 1091.6 31 117501 117531 117561 32 20.8 6.34 2474 1122.0 32 117502 117532 117562

Length Weight STANDARD PUMP

Feet Meters Lbs. Kgs. Part No.

Bolt on Head (7”-8rd) 0.97 0.30 62 28.1 117786

Coupling for Intake or GS 0.22 0.06 1.22 0.55 952572

Pump to Pump Coupling 0.22 0.06 1.22 0.55 952572

Shim Kit 0.08 0.02 0.06 0.03 131613

Pumps are center tandem configuration that can be stacked to achieve desired number of stages up to horsepower limits of shafting. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-17

Page 181: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-18 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 182: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-19

Page 183: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-20 Product Catalog - Pump Curves 862 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 184: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000A 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 17 STAGES

HIGH STRENGTH 27 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 19 STAGES HOUSING STANDARD 25 STAGES

HIGH PRESSURE 30 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 185: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000A 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 24 STAGES

HIGH STRENGTH 39 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 25 STAGES HOUSING STANDARD 36 STAGES

HIGH PRESSURE 43 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX)16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 186: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000B 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 23 STAGES

HIGH STRENGTH 36 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 23 STAGES HOUSING STANDARD 30 STAGES

HIGH PRESSURE 36 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 187: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000B 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 33 STAGES

HIGH STRENGTH 52 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 30 STAGES HOUSING STANDARD 43 STAGES

HIGH PRESSURE 51 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 188: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000C 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 29 STAGES

HIGH STRENGTH 47 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 28 STAGES HOUSING STANDARD 35 STAGES

HIGH PRESSURE 43 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

Page 189: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000C 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 42 STAGES

HIGH STRENGTH 67 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 36 STAGES HOUSING STANDARD 51 STAGES

HIGH PRESSURE 61 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 190: Wood Group ESP Catalogue

Wood Group ESP, Inc.

TN-35000 UT PUMP

950 Series - Compression Length Weight No. A-Cut B-Cut C-Cut

Hsg Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number 1 2.4 0.73 516 234.0 1 1033018 1033216 1033414 2 3.0 0.91 592 268.5 2 1033026 1033224 1033422 3 3.6 1.10 668 302.9 3 1033034 1033232 1033430 4 4.2 1.28 744 337.4 4 1033042 1033240 1033448 5 4.7 1.43 817 370.5 5 1033059 1033257 1033455 6 5.3 1.62 892 404.5 6 1033067 1033265 1033463 7 5.9 1.80 968 439.0 7 1033075 1033273 1033471 8 6.5 1.98 1044 473.5 8 1033083 1033281 1033489 9 7.1 2.16 1120 507.9 9 1033091 1033299 1033497

10 7.6 2.32 1193 541.0 10 1033109 1033307 1033505 11 8.2 2.50 1269 575.5 11 1033117 1033315 1033513 12 8.8 2.68 1345 610.0 12 1033125 1033323 1033521 13 9.4 2.87 1421 644.4 13 1033133 1033331 1033539 14 10.0 3.05 1497 678.9 14 1033141 1033349 1033547 15 10.6 3.23 1573 713.4 15 1033158 1033356 1033554 16 11.1 3.38 1649 747.6 16 1033364 1033562 17 11.7 3.57 1725 762.3 17 1033372 1033570 18 12.3 3.75 1801 816.8 18 1033380 1033588 19 12.9 3.93 1877 851.2 19 1033398 1033596 20 13.5 4.11 1953 885.7 20 1033406 1033604

Length Weight STANDARD PUMP Feet Meters Lbs. Kgs. Part No.

Coupling for Intake or GS 0.22 0.06 1.22 0.55 1032770

Pump to Pump Coupling 0.22 0.06 1.22 0.55 1032770

Shim Kit 0.08 0.02 0.02 0.01 131613 Pumps are upper tandem configuration. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Page 191: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 192: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

Page 193: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 194: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000A 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 17 STAGES

HIGH STRENGTH 27 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 19 STAGES HOUSING STANDARD 25 STAGES

HIGH PRESSURE 30 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 195: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000A 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 24 STAGES

HIGH STRENGTH 39 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 25 STAGES HOUSING STANDARD 36 STAGES

HIGH PRESSURE 43 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX)16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 196: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000B 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 23 STAGES

HIGH STRENGTH 36 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 23 STAGES HOUSING STANDARD 30 STAGES

HIGH PRESSURE 36 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 197: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000B 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 33 STAGES

HIGH STRENGTH 52 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 30 STAGES HOUSING STANDARD 43 STAGES

HIGH PRESSURE 51 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 198: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000C 60 HZ HOUSING DIAMETER 9.50 IN. MINIMUM CASING SIZE 11-3/4 IN.

SHAFT DIAMETER 1-1/2 IN. MINIMUM SHAFT AREA 1.7671 IN. SHAFT LIMIT

STANDARD 1000 HP HIGH STRENGTH 1600 HP

HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING * SHAFT STANDARD 29 STAGES

HIGH STRENGTH 47 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 28 STAGES HOUSING STANDARD 35 STAGES

HIGH PRESSURE 43 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 18000 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

Page 199: Wood Group ESP Catalogue

Wood Group ESP, Inc.

ENGINEERING DATA TN35000C 50 HZ HOUSING DIAMETER 241.30 MM MINIMUM CASING SIZE 298.45 MM

SHAFT DIAMETER 38.1 MM MINIMUM SHAFT AREA 1140.09 MM2

SHAFT LIMIT STANDARD 833 HP

HIGH STRENGTH 1333 HP HOUSING PRESSURE LIMIT

STANDARD 2300 PSI HIGH PRESSURE 2760 PSI

ROTATIONAL DIRECTION CCW

MAXIMUM STAGING:* SHAFT STANDARD 42 STAGES

HIGH STRENGTH 67 STAGES THRUST BEARING - COMPRESSION PUMP

HIGH LOAD (250ºF BHT MAX)** 36 STAGES HOUSING STANDARD 51 STAGES

HIGH PRESSURE 61 STAGES

THRUST BEARING CAPACITY HIGH LOAD (250ºF BHT MAX) 16300 LBS.

* - Maximum staging may be limited by housing pressure limit, shaft capacity or thrust loading, reference Engineering Section or contact your local Wood Group ESP representative. ** For applications above 250ºF, contact your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 200: Wood Group ESP Catalogue

Wood Group ESP, Inc.

TN-35000 UT PUMP

950 Series - Compression Length Weight No. A-Cut B-Cut C-Cut

Hsg Feet Meters Lbs. Kgs. Stages Part Number Part Number Part Number 1 2.4 0.73 516 234.0 1 1033018 1033216 1033414 2 3.0 0.91 592 268.5 2 1033026 1033224 1033422 3 3.6 1.10 668 302.9 3 1033034 1033232 1033430 4 4.2 1.28 744 337.4 4 1033042 1033240 1033448 5 4.7 1.43 817 370.5 5 1033059 1033257 1033455 6 5.3 1.62 892 404.5 6 1033067 1033265 1033463 7 5.9 1.80 968 439.0 7 1033075 1033273 1033471 8 6.5 1.98 1044 473.5 8 1033083 1033281 1033489 9 7.1 2.16 1120 507.9 9 1033091 1033299 1033497

10 7.6 2.32 1193 541.0 10 1033109 1033307 1033505 11 8.2 2.50 1269 575.5 11 1033117 1033315 1033513 12 8.8 2.68 1345 610.0 12 1033125 1033323 1033521 13 9.4 2.87 1421 644.4 13 1033133 1033331 1033539 14 10.0 3.05 1497 678.9 14 1033141 1033349 1033547 15 10.6 3.23 1573 713.4 15 1033158 1033356 1033554 16 11.1 3.38 1649 747.6 16 1033364 1033562 17 11.7 3.57 1725 762.3 17 1033372 1033570 18 12.3 3.75 1801 816.8 18 1033380 1033588 19 12.9 3.93 1877 851.2 19 1033398 1033596 20 13.5 4.11 1953 885.7 20 1033406 1033604

Length Weight STANDARD PUMP Feet Meters Lbs. Kgs. Part No.

Coupling for Intake or GS 0.22 0.06 1.22 0.55 1032770

Pump to Pump Coupling 0.22 0.06 1.22 0.55 1032770

Shim Kit 0.08 0.02 0.02 0.01 131613 Pumps are upper tandem configuration. Part numbers shown are for pumps constructed with steel housings. For design requirements not listed consult your Wood Group ESP representative.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Page 201: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 202: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009 Page-9

Page 203: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Pump Curves 950 Series - Copyright Wood Group ESP, Inc. - October, 2009

Page 204: Wood Group ESP Catalogue

Wood Group ESP, Inc.

BOLT ON INTAKES

DESCRIPTION

PUMP SERIES 338 INTAKE, PUMP BO TA STL INTAKE, PUMP BO TA SST INTAKE, PUMP BO TA AR STL INTAKE, PUMP BO TA AR SST INTAKE, PUMP BO TA AR STL HSS PUMP SERIES 387 INTAKE, PUMP BO TR387 STL INTAKE, PUMP BO TR387 SST

INTAKE, PUMP BO TR387 AR STL INTAKE, PUMP BO TR387 AR SST PUMP SERIES 400 INTAKE, PUMP BO TD STL

INTAKE, PUMP BO TD SST INTAKE, PUMP BO TD AR STL INTAKE, PUMP BO TD AR SST

INTAKE, PUMP BO TD AR STL HSS INTAKE, PUMP BO TD AR SST HSS INTAKE, PUMP BO TD AR NITRIDE INTAKE, PUMP BO TD AR FPS INTAKE, PUMP BO TD AR DURAGUARD INTAKE, PUMP BO TD AR BDP STL INTAKE, PUMP BO TD AR 316SST HSS INTAKE, PUMP BO TD AR STL UHSS INTAKE, PUMP BO TD AR 316SST UHSS PUMP SERIES 513 / 538 INTAKE, PUMP BO TE/TG STL INTAKE, PUMP BO TE/TG STL HSS INTAKE, PUMP BO TE/TG SST INTAKE, PUMP BO TE/TG AR STL INTAKE, PUMP BO TE/TG AR SST PUMP SERIES 562 INTAKE, PUMP BO TH STL INTAKE, PUMP BO TH SST INTAKE, PUMP BO TH AR STL HSS INTAKE, PUMP BO TH AR STL

INTAKE, PUMP BO TH AR SST HSS

INTAKE, PUMP BO TH AR SST

HP Rating Length 60Hz 50Hz Ft. M.

125 104 0.77 0.23 125 104 0.77 0.23 125 104 0.77 0.23 125 104 0.77 0.23 200 167 0.77 0.23

256 213 1 0.3 256 213 1 0.3 256 213 1 0.3 256 213 1 0.3

256 213 1 0.3 256 213 1 0.3 256 213 1 0.3 256 213 1 0.3 410 342 1 0.3 410 342 1 0.3 256 213 1 0.3 256 213 1 0.3 256 213 1 0.3 256 213 1 0.3 410 342 1 0.3 522 435 1 0.3 522 435 1 0.3

637 531 1.24 0.38 1019 849 1.24 0.38 637 531 1.24 0.38

1019 849 1.24 0.38 1019 849 1.24 0.38

637 531 1.24 0.38 637 531 1.24 0.38

1019 849 1.24 0.38 637 531 1.24 0.38

1019 849 1.24 0.38 637 531 1.24 0.38

Weight PART Lbs. Kgs. NO.

18 8.16 1021443 18 8.16 113143 18 8.16 113429 18 8.16 113430 18 8.16 113722

28 12.7 116080 28 12.7 116081 28 12.7 150732 28 12.7 150733

28 12.7 935858 28 12.7 1006071 28 12.7 140796 28 12.7 140800 28 12.7 140801 28 12.7 140802 28 12.7 150212 28 12.7 150593 28 12.7 150640 28 12.7 170427 28 12.7 170814 28 12.7 190063 28 12.7 190149

45 20.41 138028 45 20.41 141221 45 20.41 138029 45 20.41 138032 45 20.41 138033

50 22.68 123206 50 22.68 123410 50 22.68 136098 50 22.68 123585 50 22.68 153245 50 22.68 173022

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 1

Page 205: Wood Group ESP Catalogue

Wood Group ESP, Inc.

BOLT ON INTAKES

DESCRIPTION

PUMP SERIES 675 INTAKE, PUMP BO TJ STL INTAKE, PUMP BO TJ SST INTAKE, PUMP BO TJ STL HSS INTAKE, PUMP BO TJ AR STL INTAKE, PUMP BO TJ AR SST INTAKE, PUMP BO TJ AR SST HSS

INTAKE, PUMP BO TJ AR SST UHSS PUMP SERIES 862 INTAKE, PUMP BO TM STL INTAKE, PUMP BO TM SST INTAKE, PUMP BO TM AR SHORT STL PUMP SERIES 950 INTAKE, PUMP BO TN/TR7 SEAL STL INTAKE, PUMP BO TN/TR7 SEAL SST INTAKE, PUMP BO TN STL

INTAKE, PUMP BO TN SST

HP Rating Length 60Hz 50Hz Ft. M.

637 531 0.73 0.22 637 531 0.73 0.22 1019 849 0.73 0.22 637 531 0.73 0.22 637 531 0.73 0.22 1019 849 0.73 0.22 1281 1067 0.73 0.22

637 531 0.8 0.24 637 531 0.8 0.24 637 531 0.8 0.24

1000 833 0.83 0.25 1000 833 0.83 0.25 1000 833 0.83 0.25 1000 833 0.83 0.25

Weight PART NO.

Lbs. Kgs.

56 25.4 957498 56 25.4 117409 56 25.4 147744 56 25.4 117791 56 25.4 117819 56 25.4 147070 56 25.4 157077

75 34 977710 75 34 117961 75 34 117787

85 38.6 1033612 85 38.6 147012 85 38.6 1032705 85 38.6 1033687

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page - 2 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009

Page 206: Wood Group ESP Catalogue

Wood Group ESP, Inc.

GAS SEPARATORS Wood Group ESP offers a variety of gas separator models for different well conditions. These models are offered in all three series. It is important to mention here the features of these models.

STANDARD (3B-3 Bearing Separators): These separators are intended for use in abrasive / non-abrasive well conditions. Solid tungsten carbide bushing/sleeves are used in these units. Internal compression tubes are coated with a highly abrasive resistant coating. Units are provided with a stainless steel base. STAINLESS STEEL (SST):

In a SST construction, SST is used to make the following components. All other components are the same as the standard unit.

Head Lock ring / Compression nut Ferretic Housing (9 Chrome 1 Moly)

WAG UNITS: WAG units are designed for highly corrosive CO2 environments. These units essentially have SST construction with the following features added

SST Housing (410 SST) Lock plates are not used on these units. Housing joints are locked with a thread

XGC MODELS: XGC models are designed for applications having excessive gas. Any of the above mentioned models can be offered in XGC separators. XGVS MODELS:

The Extra Gas Volume Separator is available in 538 series for high volume applications up to 7,500 BPD liquid rate. XGVS units are constructed in corrosion resistant configuration as standard with three tungsten carbide bearings, stainless steel head and base, stainless steel internal parts, T9 housing, and Monel® K-500 shaft. The high strength shaft (HSS) option upgrades the shaft to Inconel® 718. MAGS MODELS:

The Multi-stage Abrasion-resistant Gas Separator (MAGS) of Wood Group ESP features patented designs to achieve high gas separation efficiencies in a wide range of production flow rates. The 400 series MAGS has the maximum capacity of 8,000 BPD liquid production. And the 538 series MAGS can handle liquid flow rate up to 16,000 BPD. As standard features, all MAGS units are equipped with stainless steel head and base, Tungsten Carbide (TC) bushing and sleeve for radial bearings, TC coated stainless steel compression tubes, and Ni-resist steel casting inducers, diffusers, and crossovers. The MAGS is suitable for high temperature environment with key-locked TC bushings to the bearing supports.

The 538 series gas separators (XGVS and MAGS) are Left Hand Threads. COATINGS:

Any gas separator can be supplied with coated internals. Coatings available are the same as those available for pump stages. Typical coatings are BDP (Boron Diffusion Process) for abrasives and FPS (Fluoropolymer System) for scale.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 3

Page 207: Wood Group ESP Catalogue

Wood Group ESP, Inc.

GAS SEPARATORS

DESCRIPTION

TR3 SERIES GAS SEPERATOR TR3 RS GAS SEPARATOR TR3 UT GAS SEPARATOR TR3 LT STL HSS

Length Weight Ft. M. Lbs. Kgs.

2.21 0.67 38 17.23 2.25 0.69 38 17.23 2.21 0.67 38 17.23

Part No.

113091 113275 113625

ENGINEERING DATA - TR3 SERIES

60 HZ OPERATION 50 HZ OPERATION HOUSING DIAMETER 3-3/8 IN HOUSING DIAMETER 85.85 MM SHAFT DIAMETER 11/16 IN SHAFT DIAMETER 17.42 MM SHAFT LIMIT STANDARD 125 HP SHAFT LIMIT STANDARD 104 HP

HIGH STRENGTH 200 HP HIGH STRENGTH 167 HP

DESCRIPTION

TR387 SERIES

GAS SEPARATOR TR387 3B LT STL GAS SEPARATOR TR387 3B LT SST

Length Weight Ft. M. Lbs. Kgs.

3.02 0.92 68.00 30.84 3.02 0.92 68.00 30.84

Part No.

141925 113566

ENGINEERING DATA - TR387 SERIES 60 HZ OPERATION 50 HZ OPERATION

HOUSING DIAMETER 3.87 IN HOUSING DIAMETER 98.30 MM SHAFT DIAMETER 7/8 IN SHAFT DIAMETER 22.2 MM SHAFT LIMIT STANDARD 256 HP SHAFT LIMIT STANDARD 213 HP

HIGH STRENGTH 410 HP HIGH STRENGTH 342 HP Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page - 4 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009

Page 208: Wood Group ESP Catalogue

Wood Group ESP, Inc.

GAS SEPARATORS

DESCRIPTION

TR4 SERIES GAS SEPARATOR TR4 3B LT STL GAS SEPARATOR TR4 3B LT SST GAS SEPARATOR TR4 3B LT HSS GAS SEPARATOR TR4 3B LT BDP GAS SEPARATOR TR4 3B LT FPS GAS SEPARATOR TR4 3B LT SST HSS GAS SEPARATOR TR4 3B LT SST WAG GAS SEPARATOR TR4 3B LT SST UHSS WAG GAS SEPARATOR TR4 3B LT SST SR GAS SEPARATOR TR4 3B UT STL GAS SEPARATOR TR4 3B UT SST GAS SEPARATOR TR4 UT STL HSS

GAS SEPARATOR TR4 UT SST HSS

Length Ft. M.

3.02 0.92 3.02 0.92 3.02 0.92 3.02 0.92 3.02 0.92 3.02 0.92

3.02 0.92 3.02 0.92

3.02 0.92 3.06 0.93 3.06 0.93 3.06 0.93

3.06 0.93

Weight Lbs. Kgs.

72 32.65 72 32.65 72 32.65 72 32.65 72 32.65 72 32.65

71 32.2 71 32.2

73 33.11 70 31.75 70 31.75 70 31.75

70 31.75

PART NO.

160118 150624 160122 160400 160126 160128 141464 150465 150425 160130 160132 160134 160136

GAS SEPARATOR TR4 AR MAGS-3 SST T9 HSS 6.23 1.90 143 65 192455

GAS SEPARATOR TR4 AR MAGS-3 SST HSS 6.23 1.90 143 65 192469 GAS SEPARATOR TR4 AR MAGS-3 SST T9 UHSS 6.23 1.90 143 65 192708

ENGINEERING DATA - TR4 SERIES 60 HZ OPERATION

HOUSING DIAMETER 4.00 IN SHAFT DIAMETER 7/8 IN SHAFT LIMIT STANDARD 256 HP

HIGH STRENGTH 410 HP ULTRA HIGH STRENGTH 522 HP

50 HZ OPERATION HOUSING DIAMETER 101.60 MM SHAFT DIAMETER 22.2 MM SHAFT LIMIT STANDARD 213 HP

HIGH STRENGTH 342 HP ULTRA HIGH STRENGTH 435 HP

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. – October, 2009 Page - 5

Page 209: Wood Group ESP Catalogue

Wood Group ESP, Inc.

GAS SEPARATORS

DESCRIPTION

TR5 SERIES GAS SEPARATOR TR5 3B LT STL GAS SEPARATOR TR5 3B LT SST GAS SEPARATOR TR5 3B LT STL HSS GAS SEPARATOR TR5 3B LT SST HSS GAS SEPARATOR TR5 3B LT STL BDP GAS SEPARATOR TR5 3B LT SST FPS GAS SEPARATOR TR5 3B LT SST WAG GAS SEPARATOR TR5 3B UT STL GAS SEPARATOR TR5 3B UT SST GAS SEPARATOR TR5 3B UT STL HSS GAS SEPARATOR TR5 3B UT SST HSS

Length Weight Ft. M. Lbs. Kgs.

3.2 0.98 132 59.86 3.2 0.98 132 59.86 3.2 0.98 132 59.86 3.2 0.98 132 59.86 3.2 0.98 132 59.86 3.2 0.98 132 59.86

3.2 0.98 131 59.41 3.2 0.98 140 63.49

3.2 0.98 140 63.49 3.2 0.98 140 63.49 3.2 0.98 140 63.49

PART NO.

141463 141254 151089 151458 151345 151092

151104 151106 151108 151110 151112

ENGINEERING DATA - TR5 60 HZ OPERATION

HOUSING DIAMETER 5-1/8” IN SHAFT DIAMETER 1-3/16 IN SHAFT LIMIT STANDARD 637 HP

HIGH STRENGTH 1019 HP

50 HZ OPERATION HOUSING DIAMETER 130.30 MM SHAFT DIAMETER 30.20 MM SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page - 6 Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. – October, 2009

Page 210: Wood Group ESP Catalogue

Wood Group ESP, Inc.

GAS SEPARATORS

DESCRIPTION

TR538 SERIES GAS SEPARATOR TR538 XGVS LT SST T9 GAS SEPARATOR TR538 XGVS LT SST T9 HSS GAS SEPARATOR TR538 XGVS UT SST T9 GAS SEPARATOR TR538 XGVS UT SST T9 HSS

Length Weight Ft. M. Lbs. Kgs.

3.59 1.09 140 63.49 3.59 1.09 140 63.49 3.25 0.99 135 61.22 3.25 0.99 135 61.22

PART NO.

158136 158102 158139 158122

GAS SEPARATOR TR538 AR MAGS-3 SST T9 HSS 7.70 2.35 256 116 161308 GAS SEPARATOR TR538 AR MAGS-3 SST HSS 7.70 2.35 256 116 161309 GAS SEPARATOR TR538 AR MAGS-3 SST 7.70 2.35 256 116 161325

ENGINEERING DATA - TR538 60 HZ OPERATION

HOUSING DIAMETER 5-3/8” IN SHAFT DIAMETER 1-3/16 IN SHAFT LIMIT STANDARD 637 HP

HIGH STRENGTH 1019 HP

50 HZ OPERATION HOUSING DIAMETER 136.50 MM SHAFT DIAMETER 30.20 MM SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 849 HP

TR675 SERIES Lower Tandem / Single for attachment to TR5 Seal GAS SEPARATOR TR675-TR5 LT 3.48 1.06 190 86.17 118213

GAS SEPARATOR TR675-TR5 LT SST 3.48 1.06 190 86.17 118167 GAS SEPARATOR TR675-TR5 LT HSS 3.48 1.06 190 86.17 118215 GAS SEPARATOR TR675-TR5 LT SST HSS 3.48 1.06 190 86.17 118217 lower Tandem / Single for attachment to TR7 Seal

GAS SEPARATOR TR675 LT 3.48 1.06 190 86.17 118195 GAS SEPARATOR TR675 LT SST 3.48 1.06 190 86.17 118211 GAS SEPARATOR TR675 LT HSS 3.48 1.06 190 86.17 118197 GAS SEPARATOR TR675 LT SST HSS 3.48 1.06 190 86.17 118199 Upper Tandem GAS SEPARATOR TR675 UT 3.48 1.06 190 86.17 118201 GAS SEPARATOR TR675 UT SST 3.48 1.06 190 86.17 118203 GAS SEPARATOR TR675 UT HSS 3.48 1.06 190 86.17 118205 GAS SEPARATOR TR675 UT SST HSS 3.48 1.06 190 86.17 118207

ENGINEERING DATA - TR675 60 HZ OPERATION 50 HZ OPERATION

HOUSING DIAMETER 6.750 IN HOUSING DIAMETER 171.45 MM SHAFT DIAMETER 1.187 IN SHAFT DIAMETER 30.20 MM SHAFT LIMIT STANDARD 637 HP SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HP

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Intakes / Gas Separators - Copyright Wood Group ESP, Inc. - October, 2009 Page - 7

Page 211: Wood Group ESP Catalogue

Wood Group ESP, Inc. 300 SERIES STANDARD MOTORS

3.75" / 95.25 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 7.5 6.2 410 342

10.5 8.7 390 342 315 262

AMPS

14 20.5 35.5

4-1/2" / 114.3 MM O.D. or Larger Casing PART NUMBERS LENGTH WEIGHT

UT CT LT Ft M Lbs Kgs 113102G 6.4 1.95 208 94.4 113103G 8.3 2.53 270 122 113104G 113113G 113122G

15 12.5

19.5 16.2

22.5 18.7

25.5 21.2

400 333 28 113105G 387 322 38 113106G 630 525 23 113107G 330 275 51.5 113130G 440 367 38.5 113108G 730 608 23 113109G 370 308 51 113110G 500 417 37 113131G 630 525 30 113111G

113114G 113123G 113115G 113124G 113116G 113125G 113132G 113117G 113118G 113119G 113133G 113120G

11.1 3.38 361 164

13.9 4.24 456 207

15.8 4.82 514 233

17.7 5.39 660 299

300 SERIES THD MOTORS

3.75" / 95.25 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 10 8.3 455 380 15 12.5 455 370 25 20.8 490 405

455 380

AMPS

17 26 39 50

NUMBERS UT CT

113287G 113288G 113292G 113293G 113295G 113296G

4-1/2" / 114.3 MM O.D. or Larger Casing LENGTH WEIGHT

LT Ft M Lbs Kgs 6.4 1.95 208 94.4 8.3 2.53 270 122 11.1 3.38 361 164

30 25

35 29.2

40 33.3

745 620 30 113298G 520 430 51 113304G 865 730 30 113307G 595 495 49 113313G 750 625 40 113316G

13.9 4.24 456 207 113299G 113305G

15.8 4.82 514 233 113308G 113314G

17.7 5.39 660 299 113317G

DESCRIPTION PART NUMBERS

HEAD , MTR TR3-92 BOLT-ON 113268 KIT, BASE MTR TR3 Y-PT STL 1048610 KIT, INSTALLATION TR3 1054444

LENGTH WEIGHT Ft M Lbs Kgs 1.1 0.34 28 12.7 0.5 0.15 15 6.8 NA NA 0.5 0.23

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 1

Page 212: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 2 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 213: Wood Group ESP Catalogue

Wood Group ESP, Inc. 400 SERIES STANDARD MOTORS

4.56" / 115.82 MM O.D.

5-1/2" / 139.70 MM O.D. or Larger Casing HP

60 Hz 50 Hz 10 8.7 15 12.5

20 16.5

25 20.8

30 25

35 29.2

40 33.3

50 41.7

60 50

VOLTS 60 Hz 50 Hz

435 362 435 362 610 508 450 375 750 625 410 342 690 575 810 675 425 354 750 625 400 333 675 562 750 625 420 350 770 642 880 733 1295 1079 675 562 815 679 955 796 1070 892 1210 1008 640 533 810 675 970 808 1330 1108 1945 1621

AMPS

15 23 16

28.5 17 39 22 20

44.5 25.5 55 33 28 62 33 29 20 47 39 33 31 27 59 47 39 29 20

PART NUMBERS UT CT PLUG-IN

110752G 130296G 110753G 130297G 110699G 130298G 110754G 130299G 110755G 130300G 110756G 130320G 110757G 130615G 110700G 120387G 110758G 130616G 110759G 120388G 110760G 130617G 110761G 130618G 110762G 192355G 130619G 110763G 130620G 110764G 130621G 110765G 192352G 130622G 110766G 130623G 110767G 130624G 110768G 130625G 110769G 130626G 110770G 130627G 110771G 120389G 110772G 110809G 130628G 110773G 110810G 130629G 110774G 110811G 130630G 110775G 110812G 120861G 110776G 130631G

LENGTH WEIGHT Ft M Lbs Kgs 4.1 1.25 240 109

5.3 1.62 288 131

6.5 1.98 345 156

7.7 2.35 402 183

8.9 2.71 462 210

10.1 3.08 520 236

11.3 3.44 577 262

13.7 4.18 694 315

16.5 5.03 810 367

DESCRIPTION PART NUMBERS

HEAD , MTR TR4 BO ASSY 110669 KIT, BASE MTR TR4 BO Y-PT STL 1008109 KIT, INSTALLATION TR4 1054451

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.4 32 14.5 1 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 3

Page 214: Wood Group ESP Catalogue

Wood Group ESP, Inc. 400 SERIES STANDARD MOTORS continued

4.56" / 115.82 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 540 450 750 625

70 58.3 945 787 1135 946 1310 1092 635 529 860 717

80 66.7 1085 904 1310 1092 2155 1796 710 592 960 800

1135 946

AMPS

82.5 60 47 39 35 80 60 46 39 24 81 59 50

5-1/2" / 139.70 MM O.D. or Larger Casing PART NUMBERS LENGTH WEIGHT

UT CT PLUG-IN Ft M Lbs Kgs 110777G 110813G 130632G 110778G 110814G 130633G 110779G 110815G 130634G 18.4 5.61 885 402 110780G 110816G 120390G 110781G 110817G 130635G 110782G 110818G 130636G 110783G 110819G 130637G 110784G 110820G 130638G 20.8 6.34 994 451 110785G 110821G 130639G 110786G 130640G 110787G 110822G 130641G 110788G 110823G 130642G 110789G 110824G 130643G

90 75

100 83.3

110 91.7

120 100

1220 1460 1930 775 1075 1355 2205 1190 2380 930 1040 1125 1295 2245

1017 46 110792G 1217 39 110790G 1608 31 110791G 646 84 110793G 896 59 110794G

1129 46 110795G 1837 28.5 110796G 992 60 110797G

1983 30 110798G 775 84 110799G 867 76 110800G 937 70 110801G

1079 59 110802G 1871 35 110803G

110826G 130644G 110825G 130239G

130240G 110827G 130257G 110828G 130258G 110829G 120447G

130259G 110830G 130260G

130275G 110831G 130276G 110832G 130277G 110833G 130278G 110834G 130279G

130280G

23.2 7.07 1115 506

25.6 7.8 1295 588

28 8.53 1395 632

30.4 9.27 1500 681

DESCRIPTION PART NUMBERS

HEAD , MTR TR4 BO ASSY 110669 KIT, BASE MTR TR4 BO Y-PT STL 1008109 KIT, INSTALLATION TR4 1054451

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.4 32 14.5 1 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 4 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 215: Wood Group ESP Catalogue

Wood Group ESP, Inc. 400 SERIES THD MOTORS

4.56" / 115.82 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 15 12.5 505 421 20 16.5 675 562 30 25 870 725

780 650

AMPS

20 20 23 28

5-1/2" / 139.70 MM O.D. or Larger Casing PART NUMBERS LENGTH WEIGHT UT CT Ft M Lbs Kgs

120255G 4.1 1.25 240 108.9 120257G 5.3 1.62 288 131 120259G 6.5 1.98 345 155 120261G

35

45

50

60

75

90

105

120

135

150

165

180

29.2

37.5

41.7

50

62.5

74.7

87.5

100

112.5

125

137.5

150

915 762 495 412 870 725 770 642 885 737

1020 850 1505 1254 1245 1037 1410 1175 1540 1283 2260 1883 1320 1100 1520 1267 1520 1267 2505 2087 1700 1417 2240 1867 1575 1312 2560 2133 1380 1150 2770 2308 1505 1254 2610 2175

7.7 2.35 402 25 120262G 59 120263G

8.9 2.71 462 34 120264G 42 120265G

10.1 3.08 520 36 120266G 39 120269G

11.3 3.44 577 27 120270G 41 120274G

13.7 4.18 694 36 120275G 39 120279G 120311G

16.5 5.03 810 27 120280G 52 120284G 120315G

18.4 5.61 885 47 120285G 120316G 52 120289G 120320G

20.8 6.34 994 32 120290G 52 120295G 120325G

23.2 7.07 1115 41 120296G 61 120299G 120328G

25.6 7.8 1295 38 120300G 80 120301G 120329G

28 8.53 1395 40 120302G 79 120306G 120333G

30.4 9.27 1500 47 120307G

183

210

236

262

315

368

402

451

506

588

633

681

DESCRIPTION PART NUMBERS

Head, MTR TR4 BO ASSY 110669 KIT, BASE MTR TR4 BO Y-PT STL 1008109 KIT INSTALLATION TR4 1054451

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.4 32 14.52 1 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 5

Page 216: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 6 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 217: Wood Group ESP Catalogue

Wood Group ESP, Inc. 500 SERIES STANDARD MOTORS

5.44" / 138.20 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) HP VOLTS NUMBERS

6-5/8" / 168.28 MM O.D. or Larger LENGTH WEIGHT

60 Hz 50 Hz 20 16.7

30 25

40 33.3

50 41.7 60 50

70 58.3

80 66.7

60 Hz 440 755

1020 435 710

1215 435 730 880

1325 450 725 905

1270 1375 425 645 870 970

1085 1320 755

1015 1215 865

1160 2180

AMPS 50 Hz UT 367 29 111807G 629 17 111808G 850 12 111809G 362 45 111810G 592 28 111811G 1012 16 111812G 362 60 111813G 608 36 111814G 733 30 111815G 1104 20 111816G 375 72 111817G 604 45 111818G 754 35 111819G 1058 25 111820G 1146 22 111821G 354 91 111822G 537 59 111823G 725 45 111824G 808 40 111825G 904 35 111826G 1100 30 111827G 629 60 111829G 846 45 111830G 1054 35 111831G 721 60 111832G 967 45 111833G 1817 23 111834G

CT PLUG-IN

131217G

Ft M Lbs Kgs

5 1.52 300 137

6.3 1.92 390 177

7.7 2.35 483 219

9.1 2.77 575 261

10.5 3.2 678 308

11.8 3.6 770 349

13.2 4.02 862 391

DESCRIPTION PART NUMBERS

Head, MTR TR5 UT BO ASSY 111906 KIT, BASE MTR TR5BO Y-PT STL 1017318 KIT INSTALLATION TR5 1054469

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.42 81 36.7 0.75 0.23 26 11.8 NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 7

Page 218: Wood Group ESP Catalogue

Wood Group ESP, Inc. 500 SERIES STANDARD MOTORS continued

5.40" / 137.16 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger HP

60 Hz 50 Hz

100 83.3

120 100

130 108.3

140 116.7

150 125

160 133.3

180 150

200 166.7

225 187.5

VOLTS 60 Hz 50 Hz 705 587 835 696 1070 892 1255 1046 2170 1808 855 712 1030 858 1295 1079 2165 1804 925 771 1125 937 985 821 1210 1008 2015 1679 1075 896 1240 1033 2105 1754 825 687 1115 929 2003 1699 2185 1821 945 787 1275 1062 1945 1621 2260 1883 1100 917 2140 1783 1135 946 2235 1862

AMPS

90 76 60 50 29 88 73 59 33 88 73 90 67 44 87 76 44

122 88.5 50 46

120 89 59 50

115 54

127 64

PART NUMBERS UT CT PLUG-IN

111835G 111836G 111988G 111837G 111989G 111838G 111990G 131218G 111839G 131385G 111840G 111991G 111841G 111992G 111842G 111993G 131219G 111843G 111844G 111994G 111845G 111957G 111846G 111958G 111847G 111959G 111848G 131096G 111849G 111995G 111850G 111996G 131097G 111851G 111852G 111961G 111853G 111962G 111854G 111855G 111856G 111963G 111857G 111964G 131220G 111858G 131098G 111859G 111860G 111997G 111861G 131099G 111862G 111998G 111863G 131310G

LENGTH WEIGHT Ft M Lbs Kgs

15.9 4.85 1047 471

18.7 5.7 1232 554

19.9 6.07 1287 585

21.4 6.52 1417 644

22.8 6.95 1514 688

24.2 7.38 1620 736

26.9 8.2 1833 833

29.6 9.02 2018 917

29.6 9.02 2018 917

DESCRIPTION PART NUMBERS

Head, MTR TR5 UT BO ASSY 111906 KIT, BASE MTR TR5BO Y-PT STL 1017318 KIT INSTALLATION TR5 1054469

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.42 81 36.7 0.75 0.23 26 11.8 NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 8 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 219: Wood Group ESP Catalogue

Wood Group ESP, Inc. 500 SERIES THD MOTORS

5.40" / 137.16 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 510 425

AMPS

37

NUMBERS UT CT

121155G

6-5/8" / 168.28 MM O.D. or Larger LENGTH WEIGHT

PLUG-IN Ft M Lbs Kgs

30

45

60

75

90

105

120

150

180

195

210

225

240

270

300

25

37.5

50

62.5

75

87.5

100

125

150

162.5

175

187.5

200

225

250

1190 992 15 121157G 510 425 58 121158G

1420 1183 21 121160G 1025 854 39 121163G 1545 1287 26 121164G 1055 879 45 121167G 1600 1333 28 121169G 1130 942 52 121173G 1540 1283 39 121176G 1180 983 58 121178G 1475 1229 45 121179G 1350 1125 58 121181G 2540 2117 30 121182G 1460 1217 65 121186G 2350 1958 37 121187G 1200 1000 94 121189G 2525 2104 43 121191G 1310 1092 87 121193G 1150 958 116 121194G 2350 1958 57 121196G 1250 1042 112 121197G 2455 2046 57 121199G 1300 1083 114 121201G 2550 2125 59 121203G 1490 1242 115 121205G 2640 2200 65 121207G 1280 1067 148 121208G 2500 2083 70 121998G

5 1.52 300

6.3 1.92 390

7.7 2.35 483

9.1 2.77 575

10.5 3.2 678

11.8 3.6 770

13.2 4.02 862

121211G 15.9 4.85 1047

121213G 18.7 5.7 1232

121216G 19.9 6.07 1287 121217G

21.4 6.52 1417

121219G 22.8 6.95 1514

121222G 24.2 7.38 1620

121224G 26.9 7.92 1833

121225G 29.6 9.02 2018

136

177

220

261

307

649

391

475

559

584

643

687

735

832

915

DESCRIPTION PART NUMBERS

Head, MTR TR5 UT BO ASSY 111906 KIT, BASE MTR TR5BO Y-PT STL 1017318 KIT INSTALLATION TR5 1054469

LENGTH WEIGHT Ft M Lbs Kgs 1.3 0.42 81 36.7 0.75 0.23 26 11.8 NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 9

Page 220: Wood Group ESP Catalogue

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 10 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 221: Wood Group ESP Catalogue

Wood Group ESP, Inc. E37 SERIES MOTOR

3.75" / 95.25 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 45 37.5 730 608.3 75 62.5 1200 1000

850 708.3

AMPS

48 48.5 80

4-1/2" / 114.3 MM O.D. or Larger Casing PART NUMBERS LENGTH WEIGHT

UT CT Ft M Lbs Kgs 172088G 172083G 16 4.9 685 311 172105G 172092G 24.4 7.4 1076 488 172043G 172044G

90 75 1150 958.3 53 172109G 29.1 8.9 1294 587 172111G

DESCRIPTION

BASE, MOTOR E37 BOLT ON FILTER ASSY STL BASE, MOTOR E37 BOLT ON FILTER ASSY CR BASE, MOTOR E37 BO FLTR TO SNR ASSY STL* BASE, MOTOR E37 BO FLTR TO SNR ASSY CR

PART LENGTH WEIGHT NUMBERS Ft M Lbs Kgs

172052 1.7 0.52 26 11.8 172053 1.7 0.52 26 11.8 172054 1.7 0.52 29 13.2 172055 1.7 0.52 29 13.2

*Special filter base used to attach TR3 sensors

DESCRIPTION

HEAD, MOTOR E-37 W/LP STL CT BO ASSY* HEAD, MOTOR E37 W/LP CR CT BO ASSY* HEAD, MOTOR E37 NLP STL CT BO ASSY** HEAD, MOTOR E37 NLP CR CT BO ASSY**

* For conversiont CT to UT motors with lock plates ** For conversion CT to UT motors without lock plates

DESCRIPTION

KIT, ADAPTER TR4 SEAL/E37 MTR STL KIT, ADAPTER TR4 SEAL/E37 MTR 4SS

PART LENGTH WEIGHT NUMBERS Ft M Lbs Kgs

172045 1.2 0.37 32.5 14.7 172046 1.2 0.37 32.5 14.7 172116 1.2 0.37 32 14.5 172117 1.2 0.37 32 14.5

PART LENGTH WEIGHT NUMBERS Ft M Lbs Kgs

172112 NA NA NA NA 172113 NA NA NA NA

Additional Field Service Tool required

DESCRIPTION

TOOL, ALIGNMENT TDM INVL SPLN E37

PART LENGTH WEIGHT NUMBERS Ft M Lbs Kgs

T9179 NA NA NA NA Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 11

Page 222: Wood Group ESP Catalogue

Typical E-37 Motor Performace at 60 Hertz

3,600 120

3,500 100

Speed % Amps

3,400 Power factor

80

Efficiency

3,300 60

3,200 40

3,100 20

3,000 0

20 40 60 80 100 120

% Rated Load Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 12 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 223: Wood Group ESP Catalogue

Wood Group ESP, Inc. E56 SERIES MOTOR

5.62" / 142.75 MM O.D. HP VOLTS

60 Hz 50 Hz 60 Hz 50 Hz 200 166.7 1403 1169 250 208.3 1754 1462

1744 1453

AMPS UT

86 123760 86 123768 104 123774

7" / 177.8 MM O.D. or Larger Casing PART NUMBERS LENGTH WEIGHT

CT Ft M Lbs Kgs 123882 16.7 5.1 1168 531 123890 20.2 6.2 1413 642 123896

300 250 350 291.7 400 333.3

450 375

2105 1754 86 123775 2034 1695 104 123779 2455 2046 86 123780 2325 1937 104 123782 2806 2338 86 123783 2616 2180 104 123907

23.7 7.2 1680 764 123897 123901

27.2 8.3 1934 879 123902 123904 30.8 9.4 2195 998

30.6 9.33 2195 998 34.2 10.4 2450 111

500 416.7 TBD

DESCRIPTION

HEAD, MOTOR E56 UT BO ASSY LH BASE, MOTOR E56 BO W/FILTER ASSY* BASE, MOTOR E56 BO BASE, SENSOR WIRE FILTER ASSY**

PART LENGTH WEIGHT NUMBERS Ft M Lbs Kgs

123811 1.5 0.5 88 40 123651 2.1 0.6 65 30

153172 2.1 0.6 65 30

* Equivalent of universal motor base, only with filter section. ** Special filter base used to attach TR5 Sensors Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 13

Page 224: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 14 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 225: Wood Group ESP Catalogue

3.75" / 95.25 MM O.D.

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs7.5 6.2 410 342 14 6.4 1.95 208 94.35

10.5 8.7 390 342 20.5 8.3 2.53 270 122.5315 262 35.5400 333 28387 322 38630 525 23330 275 51.5440 367 38.5730 608 23370 308 51500 417 37630 525 30

3.75" / 95.25 MM O.D.T NUMBERS LENGTH WEIGHT

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs10 8.3 455 380 17 6.4 1.95 208 94.3515 12.5 455 370 26 8.3 2.53 270 122.525 20.8 490 405 39 11.1 3.38 361 163.8

455 380 50745 620 30520 430 51865 730 30595 495 49750 625 40

Ft M Lbs Kgs1.1 0.34 28 12.70.5 0.15 15 6.8NA NA 0.5 0.23

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

DESCRIPTIONPART

NUMBERSLENGTH WEIGHT

2530

HP

300 SERIES HTI - THD MOTORS

206.8456

33.340

29.235

4.24

660113803G

113349G113436G

113802G

113350G113437G

16.2

12.5 3.38

4564.24

11.1 361

113355G

163.8

6605.39

5144.82

206.8

113354G103127G 103128G

300 SERIES HTI MOTORS

HP VOLTSAMPS

PART NUMBERS LENGTH WEIGHTUT CT

299.4

233.2514

17.7

15.8

5.39

4.82

13.9

10544441048610113268

KIT, INSTALLATION TR3KIT, BASE MTR TR3 Y-PT STLHEAD , MTR TR3-92 BOLT-ON

103129G113476G

103130G

15.8

13.9

299.4

233.2

15

19.5

17.7

VOLTSAMPS

22.5 18.7

21.225.5

UT CT

113478G

Wood Group ESP, Inc.

Page - 1

Page 226: Wood Group ESP Catalogue

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 2 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Wood Group ESP, Inc.

Page 227: Wood Group ESP Catalogue

4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs10 8.7 435 362 15 4.1 1.25 240 109

435 362 23610 508 16450 375 28.5750 625 17410 342 39690 575 22810 675 20425 354 44.5750 625 25.5400 333 55675 562 33750 625 28420 350 62770 642 33880 733 291295 1079 20675 562 47815 679 39955 796 331070 892 311210 1008 27640 533 59810 675 47970 808 391330 1108 291945 1621 20

Ft M Lbs Kgs1.3 0.4 32 14.51 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

15 12.5

6.5

2104622.718.9

183402

1563451.98

5203.08

131

315694

236

2625773.44

130019G130020G

130014G

130018G130017G130016G130015G

41.7

33.340

50

130012G130011G

LENGTH WEIGHT

192694G130041G

192529G

HP VOLTSAMPS

PART NUMBERS

KIT, BASE MTR TR4 BO Y-PT STL 1008109KIT, INSTALLATION TR4 1054451

PART NUMBERSLENGTH WEIGHT

HEAD , MTR TR4 BO ASSY 110669

DESCRIPTION

130025G130024G

5060 130023G130022G130021G

130040G130039G130038G

3678105.0316.5

400 SERIES HTI MOTORS

UT CT PLUG-IN

2881.62130001G

5.3

11.3

4.1813.7

7.7 2.35

130362G130568G

130013G

192530G

192601G

192528G

130002G130003G 192597G

130010G

130005G

35

16.520

130004G

30

25

29.2

130007G25

20.8

130008G

10.1

192599G130006G

130009G

Page - 3

Wood Group ESP, Inc.

Page 228: Wood Group ESP Catalogue

4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs540 450 82.5750 625 60945 787 47

1135 946 391310 1092 35635 529 80860 717 60

1085 904 461310 1092 392155 1796 24710 592 81960 800 59

1135 946 501220 1017 461460 1217 391930 1608 31775 646 84

1075 896 591355 1129 462205 1837 28.51190 992 602380 1983 30930 775 84

1040 867 761125 937 701295 1079 592245 1871 35

Ft M Lbs Kgs1.3 0.4 32 14.51 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 4 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

130503G

130043G

192376G130546G130505G

130027G130044G130028G

130545G130504G

120855G130034G

130507G192533G130547G130506G

130509G192452G130548G130508G

130550G130529G130549G130528G

130042G130026G

130543G192532G120954G120689G

130030G130029G

25.6 58812957.8

4519946.3420.8

50611157.0723.2

632

PLUG-IN

70 4028855.6118.458.3

130046G

400 SERIES HTI MOTORS continued

HP VOLTSAMPS

PART NUMBERS LENGTH WEIGHTUT CT

13958.532891.7

100120

130053G

83.3

110

130054G130036G

130563G130530G 68115009.2730.4

120687G

130032G

192691G

7590

192531G130544G130502G

130035G

130049G130033G

130047G130031G66.780

LENGTH

130037G192595G

100

130055G

WEIGHT

192594G130045G

120691G

120856G

130048G

KIT, BASE MTR TR4 BO Y-PT STL 1008109

DESCRIPTION PART NUMBERS

KIT, INSTALLATION TR4 1054451

HEAD , MTR TR4 BO ASSY 110669

Wood Group ESP, Inc.

Page 229: Wood Group ESP Catalogue

4.56" / 115.82 MM O.D. 5-1/2" / 139.70 MM O.D. or Larger Casing

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs15 12.5 505 421 20 4.1 1.25 240 108.920 16.5 675 562 20 5.3 1.62 288 13130 25 870 725 23 6.5 1.98 345 155

780 650 28915 762 25495 412 59870 725 34770 642 42885 737 36

1020 850 391505 1254 271245 1037 411410 1175 361540 1283 392260 1883 271320 1100 521520 1267 471525 1270 522505 2087 321695 1412 522240 1867 411575 1312 612565 2133 381385 1154 802765 2304 401505 1254 792610 2175 47

Ft M Lbs Kgs1.3 0.4 32 14.521 0.3 21 9.53

NA NA 0.21 0.1

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

HP VOLTS

35 29.2

45 37.5

CT

400 SERIES HTI - THD MOTORS

PART NUMBERS LENGTH WEIGHTAMPS

UT

50 41.7

60 50

75

180

165

150

135

120

105

90

150

137.5

125

112.5

140275G

140271G

140270G

140267G

140262G

140331G140329G140325G140324G140323G140322G140319G140318G140313G140312G

140258G140257G

140253G

140308G140307G140303G140302G140298G140297G140293G140292G140289G140288G140286G140285G140284G140283G140281G140279G140277G

1834022.357.7

8.9 2.71 462 210

10.1 3.08 520 236

11.3 3.44 577 262

13.7 4.18 694 315

16.5 5.03 810 368

18.4 5.61 885 402

20.8 6.34 994 451

23.2 7.07 1115 506

8.53 1395 633

25.6 7.8 1295 588

WEIGHT

Wood Group ESP, Inc.

Page - 5

30.4 9.27 1500 681

28

KIT INSTALLATION TR4KIT, BASE MTR TR4 BO Y-PT STLHead, MTR TR4 BO ASSY

100

87.5

74.7

62.5

LENGTHDESCRIPTION PART NUMBERS

10544511008109110669

Page 230: Wood Group ESP Catalogue

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 6 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Wood Group ESP, Inc.

Page 231: Wood Group ESP Catalogue

5.44" / 138.20 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger T NUMBERS LENGTH WEIGHT

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs440 367 29755 629 17

1020 850 12435 362 45710 592 28

1215 1012 16435 362 60730 608 36880 733 30

1325 1104 20450 375 72725 604 45905 754 35

1270 1058 251375 1146 22425 354 91645 537 59870 725 45970 808 40

1085 904 351320 1100 30755 629 60

1015 846 451265 1054 35865 721 60

1160 967 452180 1817 23

Ft M Lbs Kgs1.3 0.42 81 36.70.75 0.23 26 11.8NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

70

80

5

6.3

7.7

9.1

30

11.8

13.2

121871G

60 10.5

2.77

121863G

40

50

2.35 483

20 1.52 300

1.92 390

3.2 678

3.6 770

4.02 862

575

121868G

121874G121873G121872G

121875G 161358G

121870G121869G

121876G

121878G121786G121877G

121883G121882G121881G121879G

121884G

PART NUMBERS

151524G

136193G

121886G121707G121885G

121866G121865G121864G

500 SERIES HTI MOTORS

VOLTSHPAMPS

PLUG-INCTUT

121862G121861G

25

16.7

391

349

308

261

219

177

137

66.7

33.3

58.3

50

41.7

121867G

Page - 7

DESCRIPTION

Head, MTR TR5 UT BO ASSYKIT, BASE MTR TR5BO Y-PT STLKIT INSTALLATION TR5

10173181054469

LENGTH WEIGHT

111906

Wood Group ESP, Inc.

Page 232: Wood Group ESP Catalogue

5.40" / 137.16 MM O.D. (PLUG-IN: 5.56" / 141.22MM O.D) 6-5/8" / 168.28 MM O.D. or Larger

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs705 587 90835 696 761070 892 601255 1046 502170 1808 29855 712 881030 858 731295 1079 592165 1804 33925 771 881125 937 73985 821 901210 1008 672015 1679 441075 896 871240 1033 762105 1754 44825 687 1221115 929 88.52003 1699 502185 1821 46945 787 1201275 1062 891945 1621 592260 1883 501100 917 1152140 1783 541135 946 1272235 1862 64

Ft M Lbs Kgs1.3 0.42 81 36.70.75 0.23 26 11.8NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 8 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

151397G132673G

121917G

133.3

161357G

121915G

131757G

151811G

141853G121911G121912G

121914G

121913G

121916G

121926G

121921G

121924G121925G

121702G

121922G

121923G121928G161361G

121897G121711G121898G121899G

121918G121919G121920G

125

KIT INSTALLATION TR5

130

120

121909G121701G121910G

121906G121907G121908G

121904G121905G

121713G121900G121901G121715G121902G121903G

DESCRIPTION PART NUMBERSLENGTH

PLUG-IN

500 SERIES HTI MOTORS continued

PART NUMBERS LENGTH WEIGHT

140

WEIGHT

Head, MTR TR5 UT BO ASSY 111906KIT, BASE MTR TR5BO Y-PT STL 1017318

1054469

Wood Group ESP, Inc.

HP VOLTSAMPS

UT CT

121895G121896G

100

225

200

180

160

150

83.3

100

108.3

116.7

150

166.7

187.5

15.9

18.7

19.9

21.4

22.8

24.2

26.9

29.6

29.6

4.85

5.7

6.07

6.52

6.95

7.38

8.2

9.02

9.02

1047

1232

1287

1417

1514

1620

1833

2018

2018

471

554

585

644

688

736

833

917

917

121887G121888G121889G121709G121890G121891G121892G121893G121894G

151812G136446G

151400G

Page 233: Wood Group ESP Catalogue

5.40" / 137.16 MM O.D. 6-5/8" / 168.28 MM O.D. or Larger T NUMBERS LENGTH WEIGHT

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs510 425 37

1190 992 15510 425 58

1420 1183 211025 854 391545 1287 261055 879 451600 1333 281130 942 521540 1283 391180 983 581475 1229 451355 1129 582540 2117 301465 1221 652350 1958 371200 1000 942525 2104 43

195 162.5 1310 1092 87 19.9 6.07 1287 5841150 958 1162350 1958 571255 1046 1122455 2046 571300 1083 1142550 2125 591485 1238 1152640 2200 651285 1067 1482500 2083 70

Ft M Lbs Kgs1.3 0.42 81 36.70.75 0.23 26 11.8NA NA 1.3 0.6

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

VOLTSAMPS

UT CTHP

PLUG-IN

30 25 5141090G

1.52 300 136

45 6.3 1.92 390 17737.5

141088G

60

75

90

105

120

150

180

210

225

240

270

300

7.7 2.35 483 220

9.1 2.77 575 261

10.5 3.2 678 307

11.8 3.6 770 649

13.2 4.02 862 391

15.9 4.85 1047 475

18.7 5.7 1232 559

21.4 6.52 1417 643

22.8 6.95 1514 687

24.2 7.38 1620 735

2018 915

26.9 7.92 1833 832

50

62.5

75

87.5

100

125

150

175

187.5

200

225

250

141091G141093G141096G141097G141100G141102G141106G141108G

141133G141135G141137G

141125G141126G141128G141129G141131G

141118G141119G141121G141123G

141110G141111G141113G141114G

141028G

141049G

141066G

141030G

141048G

141069G

141086G

DESCRIPTION PART NUMBERS

141139G

141141G

LENGTH

29.6 9.02121395G

KIT INSTALLATION TR5 1054469

Page - 9

Wood Group ESP, Inc.

500 SERIES HTI - THD MOTORS

WEIGHT

Head, MTR TR5 UT BO ASSY 111906KIT, BASE MTR TR5BO Y-PT STL 1017318

Page 234: Wood Group ESP Catalogue

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 10 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Page 235: Wood Group ESP Catalogue

3.75" / 95.25 MM O.D. 4-1/2" / 114.3 MM O.D. or Larger Casing

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs45 37.5 587 489 53 16 4.9 685 31175 62.5 978 815 53 24.4 7.4 1076 48890 75 1150 958.3 53 29.1 8.9 1294 587

815

PARTNUMBERS Ft M Lbs Kgs

172052 1.7 0.52 26 11.8172053 1.7 0.52 26 11.8172054 1.7 0.52 29 13.2172055 1.7 0.52 29 13.2

*Special filter base used to attach TR3 sensors

PARTNUMBERS Ft M Lbs Kgs

172045 1.2 0.37 32.5 14.7172046 1.2 0.37 32.5 14.7172116 1.2 0.37 32 14.5172117 1.2 0.37 32 14.5

PARTNUMBERS Ft M Lbs Kgs

172112 NA NA NA NA172113 NA NA NA NA

PARTNUMBERS Ft M Lbs Kgs

T9179 NA NA NA NA

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Wood Group ESP, Inc.

E37 HTI SERIES MOTOR

HP VOLTSAMPS

PART NUMBERS LENGTH WEIGHTUT CT

172119G172123G172109G 172111G

172121G172125G

LENGTH WEIGHT

BASE, MOTOR E37 BOLT ON FILTER ASSY STL

DESCRIPTION

BASE, MOTOR E37 BOLT ON FILTER ASSY CRBASE, MOTOR E37 BO FLTR TO SNR ASSY STL*BASE, MOTOR E37 BO FLTR TO SNR ASSY CR

DESCRIPTIONLENGTH WEIGHT

HEAD, MOTOR E-37 W/LP STL CT BO ASSY*HEAD, MOTOR E37 W/LP CR CT BO ASSY*HEAD, MOTOR E37 NLP STL CT BO ASSY**HEAD, MOTOR E37 NLP CR CT BO ASSY**

* For conversiont CT to UT motors with lock plates** For conversion CT to UT motors without lock plates

DESCRIPTIONWEIGHT

KIT, ADAPTER TR4 SEAL/E37 MTR STLKIT, ADAPTER TR4 SEAL/E37 MTR 4SS

LENGTH

TOOL, ALIGNMENT TDM INVL SPLN E37

Additional Field Service Tool required

Page - 11

DESCRIPTIONLENGTH WEIGHT

Page 236: Wood Group ESP Catalogue

Typical E-37 Motor Performace at 60 Hertz

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 12 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

3,000

3,100

3,200

3,300

3,400

3,500

3,600

20 40 60 80 100 120

% Rated Load

Sp

ee

d (

RP

M)

0

20

40

60

80

100

120

% A

mp

s/E

fiic

ien

cy

/Po

we

r F

ac

tor

Speed

Efficiency

% Amps

Power factor

Page 237: Wood Group ESP Catalogue

5.62" / 142.75 MM O.D.

60 Hz 50 Hz 60 Hz 50 Hz Ft M Lbs Kgs200 166.7 1403 1169 86 16.7 5.1 1168 531250 208.3 1754 1462 86 20.2 6.2 1413 642

1744 1453 1042105 1754 862034 1695 1042455 2046 862325 1937 104 30.8 9.4 2195 9982806 2338 86 30.6 9.33 2195 998

450 375 2616 2180 104 34.2 10.4 2450 111

Ft M Lbs Kgs1.5 0.5 88 402.1 0.6 65 30

BASE, MOTOR E56 BO BASE, SENSOR WIREFILTER ASSY**

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comProduct Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009 Page - 13

LENGTH WEIGHTDESCRIPTION

65 30

300

350

400

Wood Group ESP, Inc.

E56 HTI - SERIES MOTOR

HP VOLTSAMPS

PART NUMBERS LENGTH WEIGHTUT CT

123760 123882123768

123775123774 123896

123890

123897

2.1

1680

1237801934

0.6

123782123783123907

123904

250

291.7

* Equivalent of universal motor base, only with filter section.** Special filter base used to attach TR5 Sensors

123779

500

333.3

416.7

764

879

TBD

27.2

7.2

8.3

23.7

HEAD, MOTOR E56 UT BO ASSY LHBASE, MOTOR E56 BO W/FILTER ASSY*

153172

PARTNUMBERS

123811123651

123901123902

Page 238: Wood Group ESP Catalogue

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.comPage - 14 Product Catalog - Motors - Copyright Wood Group ESP, Inc. - October, 2009

Wood Group ESP, Inc.

Page 239: Wood Group ESP Catalogue

Wood Group ESP, Inc.

MOTOR SHROUDS ENCAPSULATED PUMP SYSTEM MATERIALS OF CONTRUCTION Two material types are available, duplex stainless steel (SS) and carbon steel (CS).

Engineering should also be consulted for applications with wellbore deviation in excess of 45° or where the maximum dogleg severity (DS) exceeds 5°/100 ft. APPLICATION RATING

BURST PRESSURE

Well Casing Size PSI

COLLAPSE MAXIMUM MAXIMUM PRESSURE TENSION TEMPERATURE

PSI LBS DEGREE

MAXIMUM O.D. INCHES

7” CASING 5,000 4,800 12,000 260 5.76 7” CASING 5,000 4,200 12,000 260 5.76 5 1/2” CASING 5,000 4,800 10,000 260 4.66 5 1/2” CASING 5,000 4,200 10,000 260 4.66 Part numbers for different sizes Encapsulated Pump System are given in table below. Since each application will be unique, Wood Group ESP’s engineering department should be consulted for the quantity of the shroud material and other necessary components ordered.

PART NUMBER

DESCRIPTION 7”SS 7”CS 5 1/2” SS 5 1/2” CS SHROUD HANGER 147019 145759 147016 145760 SHROUD TOP 147023 145761 147018 145762 HANGER SCREWS 147022 147022 147017 147017 O-RING 705247 705247 705241 705241

BACK-UP RINGS 145394 145394 145400 145400 EUE PIN 147021 145763 147024 145764 EUE PIN 147376 145766 147060 145767 SECTION 147039 145768 147042 145769 SECTION 147029 145770 147041 145771 THROUGH SYSTEM 145395 145395 145395 145395 3/8” 8rd EUE 145772 145773 145772 145773 MOTOR BASE 145392 145392 145401 145401

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page - 2 Product Catalog - Motors / Motor Shrouds - Copyright Wood Group ESP, Inc. - October, 2009

Page 240: Wood Group ESP Catalogue

Application Guidelines

Seal Bags

*FKM is the abbreviation of fluoroelastomers. One common fluoroelastomer is Viton, which is a trade name ofDuPont. To call all fluoroelastomers Viton is common, but incorrect and has been addressed legally by DuPont.

**EPDM, perfluoroelastomer, is also excellent in steam applications, depending on the temperature range and chemicals.

Ratings:Excellent – Long term resistance (very low swell, maintains very high physical properties) Good – Long term resistance (moderate swell, maintains very high physical properties) Fair – Depends upon exposure time and temperature (good short term resistance) Poor – No resistance even in the short term

Note: An Application Engineer should be consulted on applications where the equipment might be subjected to a fluid with constituents other than listed in table.

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comProduct Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October 2009

Maximum BHT (applies to seal sections only) Maximum Operating Temperature

Material HSN

175°F

275°F

FKM* Aflas

300°F 350°F

400°F 450°F

Chemical HSN FKM* AflasWater/oil Excellent Good ExcellentCarbon Dioxide (CO2) Good Poor Good

Steam (geothermal applications)

Excellent PoorAmines Fair Poor

Fair Good or Fair

Fair

Elastomer seal bags are available in three materials HSN, FKM* and Aflas. The durability of the bagmaterial depends on the temperature and the environment to which it is subjected. The following chartshould be followed when selecting the right bag material for well application. Wood Group ESP’s standardbag material is HSN. More robust materials are also available to meet specific applications.

Hydrogen Sulfide (H2S) ExcellentExcellent

Fair

Fair Excellent**

Aromatic hydrocarbon (Xylene, Toluene, etc.)

Page - 1

Seal Section

Wood Group ESP, Inc.

Page 241: Wood Group ESP Catalogue

Thrust Bearing Load Calculations for all Floater Pu mps

Thrust Bearing Load Calculations for all Compressio n Pumps

Thrust Bearing Load Calculations for Combination Pu mps

Thrust Bearing Selection

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comPage - 2 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009

Compare the maximum pump thrust to the thrust bearing thrust limit. Note this is a function of temperatureand motor oil used for high load bearings. Choose a thrust bearing that has a higher thrust limit than thethrust generated by the pump. Note compression pumps will almost always require a high load bearing andengineering guidelines call for use of a high load bearing when installing compression pumps.

Floater pump thrust comes from the pump differential pressure operating on the cross-sectional area of the pumpshaft. To calculate maximum floater pump thrust use the following procedure: 1. Look in the engineering data section of the product catalog and locate the pump shaft area (A) in sq. in. 2. Look up the pump performance curve in the product catalog and locate the shut-in pump head (Hd) in ft/stageat your maximum operating frequency. 3. Calculate the maximum pump thrust using: lbf = Ft/stage x .433 x SG x A x Nstages

Where: Nstages is the number of floater pump stages, SG is the pumped fluid specific gravity

3. Calculate the maximum pump thrust using: lbf = lbf/stage x Nstages Where: Nstages = The number of compression pump stages

When you have a combination of floater and compression pump stages, calculate the thrust for each type ofpump independently and then add the results.

2. The pump thrust at different operating frequencies can be estimated from: lbf(n) = lbf(60) x (n/60) 2

Compression pump thrust comes from both the discharge pressure operating across the pump shaft areaplus the sum of the pressure differential across each pump stage acting across the stage skirt areas minusthe fluid momentum imparted on the stage by the moving fluid. The pump thrust is a function of the fluid rateand increases as the flow rate decreases. WGESP publishes compression pump thrust at shut-in conditions(the maximum). This published value already includes the pump shaft thrust. To calculate maximumcompression pump thrust used the following algorithm: 1. Look in the engineering data section of the product catalog. It contains the maximum compression pumpthrust in lbf/stage for both 60 and 50 Hz operation. (This is at shut-in)

Wood Group ESP, Inc.

Page 242: Wood Group ESP Catalogue

TR3 Series

HOUSING DIAMETER 3.375 IN HOUSING DIAMETER 85.85 MMSHAFT DIAMETER .750 IN SHAFT DIAMETER 19.05 MMSHAFT LIMIT STANDARD 160 HP SHAFT LIMIT STANDARD 133 HP

HIGH STRENGTH 256 HP HIGH STRENGTH 213 HP

TR387 SERIES

HOUSING DIAMETER 3.87 IN HOUSING DIAMETER 98.30 MMSHAFT DIAMETER SHAFT DIAMETER 22.23 MMSHAFT LIMIT STANDARD 256 HP SHAFT LIMIT STANDARD 213 HP

HIGH STRENGTH 410 HP HIGH STRENGTH 342 HP

Note: High Load (HL) bearing shown using ESP #6 oil.

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comProduct Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009

Description

SEAL,TR3 STDSEAL,TR3 STD HL,HT

5.105.10

LengthFt. M. Lbs. Kgs.

PART NO.

1.61.6

90.090.0

4141

913020113277

Weight

ENGINEERING DATA - TR3 SERIES60 HZ OPERATION 50 HZ OPERATION

DescriptionLength Weight

PART NO.Ft. M.

0.875

116613SEAL,TR387 DBG PFDB STL HL-HT AFLAS 6.10 1.9 195 88 116646SEAL,TR387 SBG PFSB STL HL-HT AFLAS 4.50

ENGINEERING DATA - TR387 SERIES60 HZ OPERATION 50 HZ OPERATION

Lbs. Kgs.1.4 101 46

Wood Group ESP, Inc.

Page - 3

TR3 Seal Thrust Bearing Capacities

1700

1900

2100

2300

2500

2700

2900

0 50 100 150 200 250 300 350 400

Motor Operating Temp. (°F)

Thr

ust L

oad

(lb)

40, 50, 60, &70 Hz - 2750 lb

30 Hz - 2400 lb

20 Hz - 1800 lb

Page 243: Wood Group ESP Catalogue

TR4 Series

HOUSING DIAMETER 4.00 IN HOUSING DIAMETER 101.60 MMSHAFT DIAMETER SHAFT DIAMETER 22.23 MMSHAFT LIMIT STANDARD 256 HP SHAFT LIMIT STANDARD 213 HP

HIGH STRENGTH 410 HP HIGH STRENGTH 342 HPULTRA HIGH STRENGTH 522 HP ULTRA HIGH STRENGTH 435 HP

Note: High Load (HL) bearing shown using ESP #6 oil.

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comPage - 4 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009

130.0 59 170787

SEAL, TR4 SBG PFSB CR

4.50SEAL,TR4 STD HL-HT 98L UHSS AFLAS 5.30 1.6SEAL,TR4 STD HL-HT 98L UHSS

SEAL, TR4 SBG PFSB HL HT STL AFLAS

SEAL, TR4 SBG PFSB HL HT STL AR AFLASSEAL,TR4 DBG PFDB STL

SEAL,TR4 SBG PFSB STL 1.4

5.30 1.6

SEAL,TR4 DBG PFDB AR CR

4.504.504.506.106.10

1.4165.0

SEAL,TR4 DBG PFDB AR HL HT 6.10

1.41.41.91.91.9

165.0165.0165.0195.0195.0

7575758888

1008275

195.0 88

1008267120377130860

1008291130853160452

75

88 170226SEAL,TR4 DBG PFDB HL-HT STL UHSS AFLAS

ENGINEERING DATA - TR4 SERIES

SEAL,TR4 DBG PFDB HL STL UHSS 6.10 1.9 195.088

60 HZ OPERATION 50 HZ OPERATION

.875 IN

PART NO.

59 140692130.0 59 190147

59 1406911.6 130.01.6 130.0

SEAL,TR4 STD HL HT 98L HSS AFLAS 5.30

DescriptionLength Weight

Ft. Kgs.M. Lbs.SEAL,TR4 STD HL HT 98L AFLAS 5.30

1709996.10 1.9 195.0

Wood Group ESP, Inc.

TR4 Seal Thrust Bearing Capacities

3000

4000

5000

6000

7000

8000

9000

0 100 200 300 400

Motor Operating Temp. (°F)

Thr

ust L

oad

(lb)

70 Hz - 8800 lb

60 Hz - 7000 lb

50 Hz - 5800 lb

40 Hz - 4800 lb

30 Hz - 4000 lb

20 Hz - 3200 lb

Page 244: Wood Group ESP Catalogue

SEAL, TR5 SBG PFSB STL HL HT AFLASSEAL, TR5 DBG PFDB STL

SEAL, TR5 DBG PFDB STL HL HSNSEAL, TR5-AR DBG PFDB HL STL HSN

SEAL, TR5 DBG PFDB STL HL HT AFLASSEAL, TR5-AR B/L HL STL AFLAS

SEAL,TR5-AR B/L HL-HT SST H&B HSS

SEAL, TR5-AR 2BP/2L HL STL HSN

SEAL, TR5-AR 2BP/2L HL STL AFLAS

HOUSING DIAMETER 5.125 IN HOUSING DIAMETER 136.50 MMSHAFT DIAMETER 1.188 IN SHAFT DIAMETER 30.20 MMAR SHAFT DIAMETER 1.375 IN AR SHAFT DIAMETER 34.90 MMSHAFT LIMIT STANDARD 637 HP SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HPAR SHAFT LIMIT STANDARD 637 HP AR SHAFT LIMIT STANDARD 531 HP

HIGH STRENGTH 1019 HP HIGH STRENGTH 849 HP

Note: High Load (HL) bearing shown using ESP #6 oil.

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comProduct Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009

SEAL,TR5-AR L/2BP HL-HT PFU SST H&B HSS

SEAL,TR5-AR L/2BP HL-HT AFLAS HSS

4.406.30

5.60

4.40141457

DescriptionFt.

Length

SEAL, TR5-AR LBYR HL 2CH STL HSN

SEAL, TR5 SBG PFSB STL

M.Weight

PART NO.Lbs. Kgs.

10196111.31.9

200.0250.0

91113

121433141595

6.306.30

2.93.9

250.0250.0

1.7

1.31.7

1217414.9 250.0

113113113

230.0

548063548279548490

200.0

141238141812

240.0230.0420.0420.0420.0420.0

540112

104

91

548083

6.305.605.609.129.129.709.70

548220

1019595

9.70SEAL,TR5-AR 2BP/2L HL HSN STL HSS LH

1.71.72.82.83.0

SEAL,TR5-AR L/L HL-HT STL SST HB HSS 5.60 230.0 104 548065

3.03.0 420.0

109104

190190

190190190

50 HZ OPERATION60 HZ OPERATIONENGINEERING DATA - TR5 SERIES

TR5 SERIES

Wood Group ESP, Inc.

Page - 5

TR5 Seal Thrust Bearing Capacities

4000

5000

6000

7000

8000

9000

10000

11000

12000

0 50 100 150 200 250 300 350 400

Motor Operating Temp. (°F)

Thr

ust L

oad

(lb)

70 Hz - 10400 lb

60 Hz - 11600 lb

50 Hz - 9200 lb

40 Hz - 8000 lb

30 Hz - 6000 lb

20 Hz - 4200 lb

Page 245: Wood Group ESP Catalogue

TR562 SERIES

HOUSING DIAMETER 5.125 IN HOUSING DIAMETER 136.50 MMSHAFT DIAMETER SHAFT DIAMETER 34.93 MMSHAFT LIMIT STANDARD 690 HP SHAFT LIMIT STANDARD 575 HP

HIGH STRENGTH 1100 HP HIGH STRENGTH 917 HP

Note: High Load (HL) bearing shown using ESP #6 oil.

Wood Group ESP, Inc. The ESP Specialists www.woodgrou p-esp.comPage - 6 Product Catalog - Seal Sections - Copyright Wood Group ESP, Inc. - October, 2009

Description

SEAL,TR562-AR 2BP/2L HL HSN STL HSS CCW, LEFT HAND THREAD

ENGINEERING DATA - TR562 SERIES

190 548301

60 HZ OPERATION 50 HZ OPERATION

PART NO.Ft. M. Lbs. Kgs.

190 548302

3.01 420.09.90

9.90 3.01 420.0

1.375 IN

SEAL,TR562-AR 2BP/2L HL HSN SST HD CCW, HSS, SST HEAD ONLY, LEFT HAND THREAD

Wood Group ESP, Inc.

Length Weight

TR562 Seal Thrust Bearing Capacities

7000

9000

11000

13000

15000

17000

19000

21000

23000

25000

0 100 200 300 400

Motor Operating Temp. (°F)

Thr

ust L

oad

(lb)

70 Hz - 24000 lb

60 Hz - 20800 lb

50 Hz - 16800 lb

40 Hz - 14000 lb

30 Hz - 11200 lb

20 Hz - 8000 lb

Page 246: Wood Group ESP Catalogue

Wood Group ESP, Inc. SMARTGUARD SENSORS

Surface Unit Options - available options for the surface interface unit DESCRIPTION PART NUMBER

OPTION, EVENT LOG EXPANSION 129134 OPTION, MEMORY EXPANSION, 7 DAY 129119 OPTION, MEMORY EXPANSION, 14 DAY 129120 OPTION, MEMORY EXPANSION, 35 DAY 129121 OPTION, I/O EXPANSION 129125 OPTION, RADIO / RS485 MULTI-DROP COMMUNICATIONS 129122 Downhole Sub-Assemblies - replacement parts - does not include motor adapter heads

SmartGuard III SmartGuard V SmartGuard VI

DOWNHOLE SUB-ASSEMBLY, STL 140470 DOWNHOLE SUB-ASSEMBLY, SST 140471 DOWNHOLE SUB-ASSEMBLY, STL 800758 DOWNHOLE SUB-ASSEMBLY, SST 800759 DOWNHOLE SUB-ASSEMBLY, STL 800777 DOWNHOLE SUB-ASSEMBLY, SST 800778

Motor Adapter Heads - replacement parts - does not include the downhole sub-assemblies HEAD, SMARTGUARD TR3 ASSY, STL 800462 HEAD, SMARTGUARD TR3 ASSY, SST 800459 HEAD, SMARTGUARD TR4 ASSY, STL 800463 HEAD, SMARTGUARD TR4 ASSY, SST 800460 HEAD, SMARTGUARD TR5 ASSY, STL 800464 HEAD, SMARTGUARD TR5 ASSY, SST 800461 X-OVER, SMARTGUARD TO CENTRILIFT MTR, STL 800489 X-OVER, SMARTGUARD TO CENTRILIFT MTR, SST 800525 Complete Systems - assembled with minimum parts required for service

SmartGuard III

TR3 SMARTGUARD III SYSTEM, STL 113626 TR3 SMARTGUARD III SYSTEM, SST 113627 TR4 SMARTGUARD III SYSTEM, STL 160476 TR4 SMARTGUARD III SYSTEM, SST 160477 TR5 SMARTGUARD III SYSTEM, STL 157061 TR5 SMARTGUARD III SYSTEM, SST 157062

Pump Discharge Subs and Auxiliary Equipment SUB, DISCHARGE 2 7/8”, STL 800620 SUB, DISCHARGE 2 7/8”, SST 800629 SUB, DISCHARGE 3 1/2”, SST 800677

SmartGuard VI SUB, DISCHARGE 4 1/2”, STL 800751 SUB, DISCHARGE 5 1/2", STL, BUTTRESS THREAD 800750 VALVE, FLOW 1/4” MALE - 1/4”, SWAGELOK 800646 TUBING, 0.250” OD X 0.049” WL, 316 SST SPECIFY LENGTH 800602

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Downhole Sensing Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 247: Wood Group ESP Catalogue

Wood Group ESP, Inc.

MOTOR LEAD CABLE

300 SERIES

DESCRIPTION SIZE

CABLE,MLC TR3 KELTB #6

TYPE ARMOR

MONEL

Length Weight PART NO.

Ft. M. Lbs. Kgs. 30 9.14 25 11.34 113388 40 12.19 33 14.97 113389 55 16.76 45 20.41 113390 70 21.34 58 26.31 113391 90 27.43 74 33.57 113392

110 33.53 91 41.28 113393

400 SERIES

DESCRIPTION SIZE

CABLE,MLC TR4 HT PLUG-IN KELB

#6 CABLE,MLC TR4 HT KELB

TYPE ARMOR

MONEL

Length Weight PART NO.

Ft. M. Lbs. Kgs. 30 9.14 31 14.06 458543 42 12.80 43 19.50 458544 58 17.68 60 27.22 458545 74 22.56 76 34.47 458546 95 28.96 98 44.45 458547

110 33.53 113 51.26 458548 30 9.14 31 14.06 136719 40 12.19 41 18.60 136720 55 16.76 57 25.86 136721 70 21.34 72 32.66 136722 90 27.43 93 42.18 136723

110 33.53 113 51.26 136724

500 SERIES

DESCRIPTION SIZE

CABLE,MLC TR5 HT PLUG-IN KELB

#4 CABLE,MLC TR5 HT KELB

TYPE ARMOR

MONEL

Length Weight PART NO.

Ft. M. Lbs. Kgs. 30 9.14 38 17.24 151557 42 12.80 54 24.49 151558 58 17.68 74 33.57 151559 74 22.56 95 43.09 151560 95 28.96 122 55.34 151561

110 33.53 141 63.96 151562 30 9.14 38 17.24 145016 40 12.19 51 23.13 145017 55 16.76 70 31.75 145018 70 21.34 90 40.82 145019 90 27.43 115 52.16 145020

110 33.53 141 63.96 145021

Wood Group ESP, Inc. The ESP Specialists www.woodgr oup-esp.com

Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 248: Wood Group ESP Catalogue

Wood Group ESP, Inc.

CABLE DESCRIPTION WIRE

SIZE

CONSTRUCTION INSULATION

JACKET ARMOR DIMENSION WEIGHT PART

Lbs/Ft NO.

FLAT PL190 3KV 16MM2 Solid PP PP GALV 0.54 x 1.37 0.85 741064

#1 0.73 x 1.92 1.70 145809

FLAT PL205 5KV #2 Solid PP NBR GALV 0.70 x 1.83 1.40 145808

#4 0.64 x 1.67 1.10 145864

FLAT PL225 5KV #2

#4 Solid PP

0.67 x 1.74 LEAD GALV

0.61 x 1.58

2.00 155000

1.60 136800 #1 0.65 x 1.69 2.10 145819

FLAT PL450 5KV #2 Solid EPDM LEAD GALV 0.62 x 1.59 1.90 145818

#4 0.56 x 1.43 1.50 145817

FLAT PL400 MLE 4KV

#2

#4

#6 6 Low Profile

Solid EPDM

0.54 x 1.48

0.48 x 1.26 LEAD MONEL 0.44 x 1.13

0.37 x 0.94

1.72 741052

1.28 925248

1.03 925255

1.28 1051499

#1 1.34 DIA 1.70 145805 ROUND PL205 5KV #2 Solid PP NITR GALV 1.28 DIA 1.50 145804

#4 1.16 DIA 1.20 145803

ROUND PL300 5KV

#1

#2

#3

EPDM Stranded/Compacted

EPDM Or Solid

EPDM

EPDM GALV 1.39 DIA

EPDM GALV 1.31 DIA

EPDM GALV 1.18 DIA

1.75 145813

1.53 145812

1.19 145811

Wood Group ESP, Inc. The ESP Specialists www.woodgr oup-esp.com

Page-2 Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009

Page 249: Wood Group ESP Catalogue

Wood Group ESP, Inc.

CABLE ACCESSORIES

CABLE CLAMPS Weight

DESCRIPTION PART NO. Lbs. Kgs.

CLAMP,CABLE STL 22” BLACK 0.20 0.09 067587 CLAMP, CABLE STL 32” BLACK 0.23 0.10 067595 CLAMP, CABLE SST 22” 0.20 0.09 208496 CLAMP, CABLE SST 32” 0.23 0.10 208504 CLAMP, CABLE MNL 22” 0.20 0.09 925644 CLAMP, CABLE MNL 32” 0.23 0.10 925651 SEALER,BANDING TOOL 4.50 2.04 560763 TENSIONER, BANDING TOOL 5.80 2.63 562983 SNIPS, METAL CUTTING 1-3/8” CUT 0.90 0.41 2642042

BANDING MATERIAL BY THE COIL BANDING, CABLE STL 3/4X.020/COIL 100 45.36 127618 BANDING, CABLE SST 3/4X.020/COIL 80 36.29 127617 BANDING, CABLE MNL 3/4X.020/COIL 55 24.95 127619

SADDLES SADDLE, CABLE #6 & #8 UNARMORED 0.05 0.02 160242

FLAT CABLE GUARDS GUARD, CABLE 3KV GALV 8FT #1-#6 5.10 2.31 935643 GUARD, CABLE 3KV SST 8FT #1-#6 5.10 2.31 145993

CABLE REEL SUPPORT SUPPORT CABLE REEL 430 195.05 925222

CABLE GUIDE WHEEL WHEEL, CABLE GUIDE 36”DIA #8-#1/0 RD/FT 115 52.16 925552 WHEEL, CABLE GUIDE 48”DIA #8-#1/0 RD/FT 150 68.04 T777

CABLE REELS NOM FLANGE SIZE DIAMETER 50.0 50 IN 66.0 66 IN 78.0 78 IN 78.0 78 IN - Heavy Duty 84.0 84 IN 90.0 90 IN

DRUM TRAVERSE OVERALL Weight DIA. WIDTH WIDTH Lbs. Kgs. 30.0 40.0 46.0 331 150.14 33.0 40.0 46.0 441 200.04 35.0 54.0 60.0 772 350.18 42.0 57.0 64.0 1037 470.38 35.0 54.0 60.0 992 449.97 42.0 57.0 64.0 1248 566.09

PART NO.

741101 741102 741103 132688 741104 741105

Wood Group ESP, Inc. The ESP Specialists www.woodgr oup-esp.com

Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 250: Wood Group ESP Catalogue

Wood Group ESP, Inc.

CABLE REEL CAPACITIES

ROUND CABLES (Feet per Reel)

REEL SIZE CABLE PART CABLE TYPE NUMBER SIZE 78”

66” 78” Heavy 84” 90” Duty

145805 1 AWG 2500 6500 6500 7700 10000 PL205 145804 2 AWG 3000 6700 6700 8900 10300

145803 4 AWG 3100 7800 7800 10200 12600 145813 1 AWG 2400 5500 5500 6800 8800

PL300 145812 2 AWG 3943 7179 7179 9066 10953 145811 4 AWG 4888 8898 8898 11237 13577

FLAT CABLES (Feet per Reel) PL190 741064 16 MM2 10300 18000 24000 25000 29000

145809 1 AWG 3451 6283 6283 7935 9587 PL205 145808 2 AWG 4300 9000 10200 12000 14500

145864 4 AWG 5300 11700 12100 15700 18900

PL225 155000 2 AWG 136800 4 AWG

4042 5520 7619 7619 8940 5200 7100 9800 9800 11500

145819 1 AWG 3000 6100 8500 8500 9900 PL450 145808 2 AWG 3400 6900 9600 9600 11200

145807 4 AWG 4300 8600 12000 12000 14000

Wood Group ESP, Inc. The ESP Specialists www.woodgr oup-esp.com

Page-4 Product Catalog - Downhole Cables - Copyright Wood Group ESP, Inc. - October, 2009

Page 251: Wood Group ESP Catalogue

Vector ® VII

Product Data Book

Wood Group ESP 5500 S.E. 59th Street Oklahoma City, OK 73135 Tel 405-670-1431 www.woodgroup-esp.com

Page 252: Wood Group ESP Catalogue

© Wood Group-ESP 2009 2

TERM DEFINITIONS

TERM DEFINITION

°C Degrees Celcius

°F Degrees Farenheit

AC Alternating current

ASD Adjustable speed drive

COMM Communications

DC Direct current

DPF Displacement power factor

ESP Electric submersible pump

I/O Inputs / Outputs

IEC International electric code

IGBT Insulated gate bi-polar transistor

ISO International Organization for Standardization

LCD Liquid crystal display

MODBUS Serial Communication Protocol

PI Proportional Integral

PCP Progressing cavity pump

SCADA Supervisory Control and Data Acquisition

SPS Surface pumping systems

THD Total harmonic distortion

TVSS Transient voltage surge suppression

VAC Volts AC

VDC Volts DC

VFD Variable frequency drive

VSD Variable speed drive

VSG® Variable Sinewave Generator

Page 253: Wood Group ESP Catalogue

© Wood Group-ESP 2009 3

TABLE OF CONTENTS

TOPIC PAGE NUMBER Term Definitions 2 Safety Notice 4 Introduction 5 Drive Description 5 Vector ® VII Product Summary 6 Installation Examples 8 Catalog Number Explanation 9 Vector ® VII without VSG ® Catalog Numbers - 60 Hertz 10 Vector ® VII with VSG ® Catalog Numbers - 60 Hertz 11 Vector ® VII without VSG ® Catalog Numbers - 50 Hertz 12 Vector ® VII with VSG ® Catalog Numbers - 50 Hertz 13 Vector ® VII Factory Installed Options 14 Manufacturer Qualifications and Certifications 15 General Specifications / Operating Conditions / Des ign Features 15 Operator Panel 20

Surface Pumping Systems (SPS™) 29 Input Harmonic Mi tigation 30 Basic 12 Pulse and 18 Pulse Drive Schematics 31 Output Harmonic Mitigation

32

Grounding and Bonding / Typical 480 VAC Drive Insta llation 33 Generator Requirements 34 Dimensions and Weights 36

Page 254: Wood Group ESP Catalogue

© Wood Group-ESP 2009 4

SAFETY NOTICE

Wood Group ESP, Inc. places a high priority upon personnel safety. Personnel performing maintenance upon drives should be properly trained and follow all safety procedures to prevent injury. Drives may cause serious injury if proper safety precautions, equipment, and installation procedures are not used. Units should always be grounded and confirmation of ground connection and continuity be established prior to performing any work or service. Be sure to consult user’s manual before installing, energizing, or operating equipment. Installation should always conform to local codes, regulations, or other authorities governing electrical equipment.

Page 255: Wood Group ESP Catalogue

© Wood Group-ESP 2009 5

INTRODUCTION

This document provides a descriptive overview of the Vector® VII Variable Speed Drive (VSD) available from Wood Group ESP. Information is provided on available ratings, physical size, product features, general operation, and available options. Additional details regarding drive set-up, operation, and troubleshooting are available in the Vector VII Variable Speed Drive User’s Manual. The descriptions and information contained in this publication are for informational purposes only and should not be used to install, set-up, program, or operate the Vector VII drive. Note: This publication describes the standard Vector VII Variable Speed Drive and includes descriptions of the most common drive options and modifications. Specific features may be added (or disabled) from the product depending on the specific application. All specifications and information contained in this publication are subject to change without notice. DRIVE DESCRIPTION The Vector VII Variable Speed Drive is designed specifically for oil-field pumping applications including electrical submersible pumps (ESP) and surface pumping systems (SPS). Vector VII drives are available in ratings from 104 KVA to1500 KVA. They are provided in rugged outdoor rated enclosures designed for a wide variety of environments ranging from arctic to desert conditions. Application specific software and a Wood Group ESP Custom Operator Control Panel combine to optimize pump control while simplifying drive operation.

Vector VII uses the latest Insulated Gate Bipolar Transistor (IGBT) technology in combination with surface mount printed circuit boards to create a VSD of the highest reliability, and small physical size. Fixed voltage, three-phase AC input power is first converted to a fixed DC bus voltage by the input rectifier section of the drive. That fixed DC bus voltage is then processed by the inverter section to produce a sine coded variable voltage, variable frequency output to control the speed of the motor.

For ESP applications, the Vector VII Variable Speed Drive is available with integrated VSG® Technology. With VSG Technology the drive output voltage waveform is a near perfect sine-wave which results in improved motor performance, extended motor run life, extended motor cable life, and increased operational efficiency in the driven equipment. Vector VII drives with VSG (Variable Sinewave Generation) technology can successfully operate with motor cable lengths up to 15,000 ft. User adjustments include operating speed, acceleration and deceleration rates, motor overload protection settings, auto restarts, time delays, and stopping methods. Control methods include frequency control, current control, pressure control, or analog follower (Analog 1 = 0-10 VDC, Analog 2 = 0-10 VDC or 4-20 mA) capability.

Page 256: Wood Group ESP Catalogue

© Wood Group-ESP 2009 6

VECTOR VII PRODUCT SUMMARY

Standard Drive Features:

• Ratings from 104 KVA to 1500 KVA. • Specifically designed for oil field pumping applications. • NEMA 3R outdoor enclosure, rugged (10 Gauge) steel construction with compact footprint. • Enclosure base pre-drilled with slotted holes for permanent attachment to foundation. • Three point door latching mechanism. • Designed for 50ºC (122º F) ambient temperature, white enclosure reduces solar heating. • Input AC line circuit breaker with pad lockable flange mount external operator. • State of the art operator control panel with graphical interface. • Available with or without Variable Sinewave Generator (VSG) technology – pure sine wave output. • Latest generation IGBTs (Insulated Gate Bipolar Transistors). • Microprocessor based control circuitry with non-volatile memory for all drive parameters. • Surface mount technology with protective coating on all printed circuit boards. • Input line transient voltage suppression - line to line and line to ground voltage surge protection. • Six pulse input rectification (standard) or optional multi-pulse rectification for reduced AC line harmonics. • Fused control power transformer. • Extended acceleration time - reduces electrical and mechanical stress on pump and motor. • “S” curve soft start / soft stop capability. • Power loss ride through capability.

Operator Panel Features:

• Intuitive operator friendly menu is easy to use. • Large bright screen is easy to read in direct sunlight. • Built in real time clock – provides time and date stamp for historical data and event logger. • Operator control panel monitors both drive parameters and well parameters. Note: Wood Group ESP downhole sensor is required to monitor well parameters. • Drive and well parameters are displayed in engineering units using plain language text. • User programmable functions and operating modes. • Set point PI control – closed loop – programmable in engineering units. • Comprehensive run status screen shows critical drive and well data in a single location. • Time stamped event and fault log - stores last 256 drive events including faults, starts, stops, operator

changes, etc. • Historical data log - periodically samples and stores the values of 20 different drive and well parameters. - All parameters are time (to the second) and date stamped with 35 days of data retained. • Trending screen – graphically displays historical data for important drive and well parameters. • Software embedded circular recording ammeter – high resolution display with 1 day or 7 day format. • Drive Status Lights - Shows drive operating mode and are visible from a distance. • Software embedded drive lock-out and auto-restart switches. • Programmable restart capability. • USB port for data retrieval and transfer of drive information to memory stick.

- Save historical data, event log information, recording ammeter data, and drive configuration information.

• Built in Modbus communications port – easy interface to customer SCADA systems. • Multiple Languages • Password protection to prevent unauthorized changes.

Page 257: Wood Group ESP Catalogue

© Wood Group-ESP 2009 7

Protective Features:

• Input phase insensitive – sequencing of 3 phase input power is not necessary. • DC bus reactor. • Diagnostic fault indication. • Loss of load detection. • Serial communication loss detection. • Short circuit protection. • Ground fault protection. • Loss of input phase protection. • Over voltage and under voltage protection. • Over current and under current protection. • Current limiting DC bus fuse. • Motor stall protection. • Heat sink over temperature protection. • Adjustable motor current limit. • Critical frequency avoidance – three selectable frequencies with adjustable bandwidth.

Electrical Specifications: Rated Input Voltage: 480 Volt, 3 phase, 60 Hz (+ / - 10% of rated voltage and frequency). Consult factory for other input voltages and frequency ratings. Efficiency: 97% or greater at full load. Power Factor: .95 or greater – Constant over operating range – Not speed or load dependent Output Voltage: 0 Volts to rated input voltage Output Frequency: 0 Hertz to 120 Hertz. Control Specifications: Control Method: Sine coded output with optional VSG (Variable Sinewave Generation) technology. Accel / Decel: 0 Seconds to 6,000 seconds. Drive Overload: 110% of drive rating for 60 seconds (Variable Torque). Current Limit: Programmable current limit. Control I/O: Digital Inputs: 7 Programmable inputs - 24 VDC, 8 mA – Sinking or Sourcing Logic. Digital Outputs: 2 Programmable dry contacts rated 250 VAC / 30 VDC @ 1A.

1 Fault contact - Form C dry contact rated 250 VAC / 30 VDC @ 1A. Analog Inputs: 2 Programmable inputs (10 bit). Analog 1 = 0 to +10 VDC – 20 K Ohms Analog 2 = 0 to +10 VDC – 20 K Ohms or 4 to 20 mA – 250 Ohms Analog Outputs: 2 Programmable outputs (10 bit) each = 0 to +10 VDC – 2 mA. Analog Reference: +15 VDC Source – 20 mA. Logic Reference: +24 VDC Source – 8 mA. Environmental Specifications: Ambient Service Temperature: 0°C to 50°C (32°F to 122°F) to -40°C (-40°F) with optional arctic package. Ambient Storage Temperature: -20°C to 60°C (-4°F to 140°F) Humidity: 0 to 100% Altitude: Up to 1000 Meters (3300 Feet) without de-rate. Vibration: 9.81m/s2 (1 G) maximum at 10 to 20 Hz, 2.0 m/s2 (0.2 G) at 20 Hz to 50 Hz.

Page 258: Wood Group ESP Catalogue

© Wood Group-ESP 2009 8

Various Installation Examples

ESP Installation SPS Ins tallation

ESP Installation

ESP Installation Offshore Installati on

Page 259: Wood Group ESP Catalogue

© Wood Group-ESP 2009 9

CATALOG NUMBER EXPLANATION Position A B C D E F G H to Z

Description Drive Type Rated

Amps Rated Volts Rated

Hertz

Pulse Enclosure Type Output

Type Options

Example V7 - 675A - 480V - 60HZ - 6P - N3R - VSG - AP

Position

Description

Choices

A Vector 7 Drive V7 B Output Amps 180A, 304A, 414A, 515A, 675A, 910A, 1 215A,

1366A, 1444A, 1821A, Other C Input Voltage 480VAC, 380VAC, 400VAC, Other D Input Frequency 60HZ, 50HZ E Input Type 6P = 6 Pulse, 12P = 12 Pulse, 18P = 18 Pulse,

Other F Enclosure Type N3R = Nema 3R, N1 = Nema 1, Other G Output Type VSG = Sine Wave, No Entry = PWM

H – Z Options See Options Table on Page 14

Page 260: Wood Group ESP Catalogue

© Wood Group-ESP 2009 10

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives – without VSG (5) - 480 VAC / 60 Hertz

Catalog Number Output KVA (4)

Input Pulses

Output Voltage

Output Amperes

Input Voltage

Input Amperes

V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136 V7-124A-480V-60HZ-12P-N3R (3) 104 12 480 124 480 136 (1) V7-124A-480V-60HZ-18P-N3R (3) 104 18 480 124 480 136 (2) V7-180A-480V-60HZ-6P-N3R 150 6 480 180 480 198 V7-180A-480V-60HZ-12P-N3R (3) 150 12 480 180 480 198 (1) V7-180A-480V-60HZ-18P-N3R (3) 150 18 480 180 480 198 (2) V7-240A-480V-60HZ-6P-N3R 200 6 480 240 480 264 V7-240A-480V-60HZ-12P-N3R (4) 200 12 480 240 480 264 (1) V7-240A-480V-60HZ-18P-N3R (4) 200 18 480 240 480 264 (2) V7-304A-480V-60HZ-6P-N3R 253 6 480 304 480 334 V7-304A-480V-60HZ-12P-N3R (3) 253 12 480 304 480 334 (1) V7-304A-480V-60HZ-18P-N3R (3) 253 18 480 304 480 334 (2) V7-414A-480V-60HZ-6P-N3R 344 6 480 414 480 456 V7-414A-480V-60HZ-12P-N3R (3) 344 12 480 414 480 456 (1) V7-414A-480V-60HZ-18P-N3R (3) 344 18 480 414 480 456 (2) V7-515A-480V-60HZ-6P-N3R 428 6 480 515 480 567 V7-515A-480V-60HZ-12P-N3R (3) 428 12 480 515 480 567 (1) V7-515A-480V-60HZ-18P-N3R (3) 428 18 480 515 480 567 (2) V7-675A-480V-60HZ-6P-N3R 561 6 480 675 480 743 V7-675A-480V-60HZ-12P-N3R (3) 561 12 480 675 480 743 (1) V7-675A-480V-60HZ-18P-N3R (3) 561 18 480 675 480 743 (2) V7-910A-480V-60HZ-6P-N3R 757 6 480 910 480 1000 V7-910A-480V-60HZ-12P-N3R (3) 757 12 480 910 480 1000 (1) V7-910A-480V-60HZ-18P-N3R (3) 757 18 480 910 480 1000 (2) V7-1215A-480V-60HZ-6P-N3R 1010 6 480 1215 480 1340 V7-1215A-480V-60HZ-12P-N3R (3) 1010 12 480 1215 480 1340 (1) V7-1215A-480V-60HZ-18P-N3R (3) 1010 18 480 1215 480 1340 (2) V7-1366A-480V-60HZ-6P-N3R 1136 6 480 1366 480 1500 V7-1366A-480V-60HZ-12P-N3R (3) 1136 12 480 1366 480 1500 (1) V7-1366A-480V-60HZ-18P-N3R (3) 1136 18 480 1366 480 1500 (2) V7-1444A-480V-60HZ-6P-N3R 1200 6 480 1444 480 1590 V7-1444A-480V-60HZ-12P-N3R (3) 1200 12 480 1444 480 1590 (1) V7-1444A-480V-60HZ-18P-N3R (3) 1200 18 480 1444 480 1590 (2) V7-1821A-480V-60HZ-6P-N3R 1514 6 480 1821 480 2000 V7-1821A-480V-60HZ-12P-N3R (3) 1514 12 480 1821 480 2000 (1) V7-1821A-480V-60HZ-18P-N3R (3) 1514 18 480 1821 480 2000 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value. (2) Total input amperes. Amperes per input phase are 33% of listed value. (3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive.

(4) Output KVA calculated at 480 VAC. (5) VSG is required for ESP applications.

Page 261: Wood Group ESP Catalogue

© Wood Group-ESP 2009 11

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives with VSG - 480 VAC / 60 Hertz

Catalog Number Output KVA (4)

Input Pulses

Output Voltage

Output Amperes

Input Voltage

Input Amperes

V7-124A-480V-60HZ-6P-N3R 104 6 480 124 480 136 V7-124A-480V-60HZ-12P-N3R (3) 104 12 480 124 480 136 (1) V7-124A-480V-60HZ-18P-N3R (3) 104 18 480 124 480 136 (2) V7-180A-480V-60HZ-6P-N3R-VSG 150 6 480 180 480 198 V7-180A-480V-60HZ-12P-N3R-VSG (3) 150 12 480 180 480 198 (1) V7-180A-480V-60HZ-18P-N3R-VSG (3) 150 18 480 180 480 198 (2) V7-240A-480V-60HZ-6P-N3R-VSG 200 6 480 240 480 264 V7-240A-480V-60HZ-12P-N3R-VSG (3) 200 12 480 240 480 264 (1) V7-240A-480V-60HZ-18P-N3R-VSG (3) 200 18 480 240 480 264 (2) V7-304A-480V-60HZ-6P-N3R-VSG 253 6 480 304 480 334 V7-304A-480V-60HZ-12P-N3R-VSG (3) 253 12 480 304 480 334 (1) V7-304A-480V-60HZ-18P-N3R-VSG (3) 253 18 480 304 480 334 (2) V7-414A-480V-60HZ-6P-N3R-VSG 344 6 480 414 480 456 V7-414A-480V-60HZ-12P-N3R-VSG (3) 344 12 480 414 480 456 (1) V7-414A-480V-60HZ-18P-N3R-VSG (3) 344 18 480 414 480 456 (2) V7-515A-480V-60HZ-6P-N3R-VSG 428 6 480 515 480 567 V7-515A-480V-60HZ-12P-N3R-VSG (3) 428 12 480 515 480 567 (1) V7-515A-480V-60HZ-18P-N3R-VSG (3) 428 18 480 515 480 567 (2) V7-675A-480V-60HZ-6P-N3R-VSG 561 6 480 675 480 743 V7-675A-480V-60HZ-12P-N3R-VSG (3) 561 12 480 675 480 743 (1) V7-675A-480V-60HZ-18P-N3R-VSG (3) 561 18 480 675 480 743 (2) V7-910A-480V-60HZ-6P-N3R-VSG 757 6 480 910 480 1000 V7-910A-480V-60HZ-12P-N3R-VSG (3) 757 12 480 910 480 1000 (1) V7-910A-480V-60HZ-18P-N3R-VSG (3) 757 18 480 910 480 1000 (2) V7-1215A-480V-60HZ-6P-N3R-VSG 1010 6 480 1215 480 1340 V7-1215A-480V-60HZ-12P-N3R-VSG (3) 1010 12 480 1215 480 1340 (1) V7-1215A-480V-60HZ-18P-N3R-VSG (3) 1010 18 480 1215 480 1340 (2) V7-1366A-480V-60HZ-6P-N3R-VSG 1136 6 480 1366 480 1500 V7-1366A-480V-60HZ-12P-N3R-VSG (3) 1136 12 480 1366 480 1500 (1) V7-1366A-480V-18P-N3R-VSG (3) 1136 18 480 1366 480 1500 (2) V7-1444A-480V-60HZ-6P-N3R-VSG 1200 6 480 1444 480 1590 V7-1444A-480V-60HZ-12P-N3R-VSG (3) 1200 12 480 1444 480 1590 (1) V7-1444A-480V-60HZ-18P-N3R-VSG (3) 1200 18 480 1444 480 1590 (2) V7-1821A-480V-60HZ-6P-N3R-VSG 1514 6 480 1821 480 2000 V7-1821A-480V-60HZ-12P-N3R-VSG (3) 1514 12 480 1821 480 2000 (1) V7-1821A-480V-60HZ-18P-N3R-VSG (3) 1514 18 480 1821 480 2000 (2) (1) Total input amperes. Amperes per input phase are 50% of listed value. (2) Total input amperes. Amperes per input phase are 33% of listed value. (3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive. (4) Output KVA calculated at 480 VAC. (5) VSG is required for ESP applications.

Page 262: Wood Group ESP Catalogue

© Wood Group-ESP 2009 12

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives –without VSG (5) - 380 VAC / 50 Hertz

Catalog Number Output KVA (4)

Input Pulses

Output Voltage

Output Amperes

Input Voltage

Input Amperes

V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136 V7-124A-480V-50HZ-12P-N3R (3) 82 12 380 124 380 136 (1) V7-124A-480V-50HZ-18P-N3R (3) 82 18 380 124 380 136 (2) V7-180A-380V-50HZ-6P-N3R 118 6 380 180 380 198 V7-180A-380V-50HZ-12P-N3R (3) 118 12 380 180 380 198 (1) V7-180A-380V-50HZ-18P-N3R (3) 118 18 380 180 380 198 (2) V7-240A-380V-50HZ-6P-N3R 158 6 380 240 380 264 V7-240A-380V-50HZ-12P-N3R (3) 158 12 380 240 380 264 (1) V7-240A-380V-50HZ-18P-N3R (3) 158 18 380 240 380 264 (2) V7-304A-380V-50HZ-6P-N3R 200 6 380 304 380 334 V7-304A-380V-50HZ-12P-N3R (3) 200 12 380 304 380 334 (1) V7-304A-380V-50HZ-18P-N3R (3) 200 18 380 304 380 334 (2) V7-414A-380V-50HZ-6P-N3R 272 6 380 414 380 456 V7-414A-380V-50HZ-12P-N3R (3) 272 12 380 414 380 456 (1) V7-414A-380V-50HZ-18P-N3R (3) 272 18 380 414 380 456 (2) V7-515A-380V-50HZ-6P-N3R 338 6 380 515 380 567 V7-515A-380V-50HZ-12P-N3R (3) 338 12 380 515 380 567 (1) V7-515A-380V-50HZ-18P-N3R (3) 338 18 380 515 380 567 (2) V7-675A-380V-50HZ-6P-N3R 444 6 380 675 380 743 V7-675A-380V-50HZ-12P-N3R (3) 444 12 380 675 380 743 (1) V7-675A-380V-50HZ-18P-N3R (3) 444 18 380 675 380 743 (2) V7-819A-380V-50HZ-6P-N3R 539 6 380 819 380 901 V7-819A-380V-50HZ-12P-N3R (3) 539 12 380 819 380 901 (1) V7-819A-380V-50HZ-18P-N3R (3) 539 18 380 819 380 901 (2) V7-1093A-380V-50HZ-6P-N3R 719 6 380 1093 380 1202 V7-1093A-380V-50HZ-12P-N3R (3) 719 12 380 1093 380 1202 (1) V7-1093A-380V-50HZ-18P-N3R (3) 719 18 380 1093 380 1202 (2) V7-1229A-380V-50HZ-6P-N3R 809 6 380 1229 380 1352 V7-1229A-380V-50HZ-12P-N3R (3) 809 12 380 1229 380 1352 (1) V7-1229A-380V-50HZ-18P-N3R (3) 809 18 380 1229 380 1352 (2) V7-1300A-380V-50HZ-6P-N3R 856 6 380 1300 380 1430 V7-1300A-380V-50HZ-12P-N3R (3) 856 12 380 1300 380 1430 (1) V7-1300A-380V-50HZ-18P-N3R (3) 856 18 380 1300 380 1430 (2) V7-1639A-380V-50HZ-6P-N3R 1079 6 380 1639 380 1803 V7-1639A-380V-50HZ-12P-N3R (3) 1079 12 380 1639 380 1803 (1) V7-1639A-380V-50HZ-18P-N3R (3) 1079 18 380 1639 380 1803 (2)

(1) Total input amperes. Amperes per input phase are 50% of listed value. (2) Total input amperes. Amperes per input phase are 33% of listed value. (3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive. (4) Output KVA calculated at 380 VAC. (5) VSG is required for ESP applications.

Page 263: Wood Group ESP Catalogue

© Wood Group-ESP 2009 13

VECTOR VII RATINGS AND CATALOG NUMBERS

Vector VII Drives with VSG - 380 VAC / 50 Hertz

Catalog Number Output KVA (4)

Input Pulses

Output Voltage

Output Amperes

Input Voltage

Input Amperes

V7-124A-480V-50HZ-6P-N3R 82 6 380 124 380 136 V7-124A-480V-50HZ-12P-N3R (3) 82 12 380 124 380 136 (1) V7-124A-480V-50HZ-18P-N3R (3) 82 18 380 124 380 136 (2) V7-180A-380V-50HZ-6P-N3R-VSG 118 6 380 180 380 198 V7-180A-380V-50HZ-12P-N3R-VSG (3) 118 12 380 180 380 198 (1) V7-180A-380V-50HZ-18P-N3R-VSG (3) 118 18 380 180 380 198 (2) V7-240A-380V-50HZ-6P-N3R-VSG 158 6 380 240 380 264 V7-240A-380V-50HZ-12P-N3R-VSG (3) 158 12 380 240 380 264 (1) V7-240A-380V-50HZ-18P-N3R-VSG (3) 158 18 380 240 380 264 (2) V7-304A-380V-50HZ-6P-N3R-VSG 200 6 380 304 380 334 V7-304A-380V-50HZ-12P-N3R-VSG (3) 200 12 380 304 380 334 (1) V7-304A-380V-50HZ-18P-N3R-VSG (3) 200 18 380 304 380 334 (2) V7-414A-380V-50HZ-6P-N3R-VSG 272 6 380 414 380 456 V7-414A-380V-50HZ-12P-N3R-VSG (3) 272 12 380 414 380 456 (1) V7-414A-380V-150HZ-8P-N3R-VSG (3) 272 18 380 414 380 456 (2) V7-515A-380V-50HZ-6P-N3R-VSG 338 6 380 515 380 567 V7-515A-380V-50HZ-12P-N3R-VSG (3) 338 12 380 515 380 567 (1) V7-515A-380V-50HZ-18P-N3R-VSG (3) 338 18 380 515 380 567 (2) V7-675A-380V-50HZ-6P-N3R-VSG 444 6 380 675 380 743 V7-675A-380V-50HZ-12P-N3R-VSG (3) 444 12 380 675 380 743 (1) V7-675A-380V-50HZ-18P-N3R-VSG (4) 444 18 380 675 380 743 (2) V7-819A-380V-50HZ-6P-N3R-VSG 539 6 380 819 380 901 V7-819A-380V-50HZ-12P-N3R-VSG (3) 539 12 380 819 380 901 (1) V7-819A-380V-50HZ-18P-N3R-VSG (3) 539 18 380 819 380 901 (2) V7-1093A-380V-50HZ-6P-N3R-VSG 719 6 380 1093 380 1202 V7-1093A-380V-50HZ-12P-N3R-VSG(3) 719 12 380 1093 380 1202 (1) V7-1093A-380V-50HZ-18P-N3R-VSG(3) 719 18 380 1093 380 1202 (2) V7-1229A-380V-50HZ-6P-N3R-VSG 809 6 380 1229 380 1352 V7-1229A-380V-50HZ-12P-N3R-VSG(3) 809 12 380 1229 380 1352 (1) V7-1229A-380V-50HZ-18P-N3R-VSG(3) 809 18 380 1229 380 1352 (2) V7-1300A-380V-50HZ-6P-N3R-VSG 856 6 380 1300 380 1430 V7-1300A-380V-50HZ-12P-N3R-VSG(3) 856 12 380 1300 380 1430 (1) V7-1300A-380V-50HZ-18P-N3R-VSG(3) 856 18 380 1300 380 1430 (2) V7-1639A-380V-50HZ-6P-N3R-VSG 1079 6 380 1639 380 1803 V7-1639A-380V-50HZ-12P-N3R-VSG(3) 1079 12 380 1639 380 1803 (1) V7-1639A-380V-50HZ-18P-N3R-VSG(3) 1079 18 380 1639 380 1803 (2) (1) Total input amperes. Amperes per input phase are 50% of listed value. (2) Total input amperes. Amperes per input phase are 33% of listed value. (3) Multi-pulse drives require a Phase Shift Transformer. This is not included with the drive. (4) Output KVA calculated at 380 VAC. (5) VSG is required for ESP applications.

Page 264: Wood Group ESP Catalogue

© Wood Group-ESP 2009 14

OPTIONS TABLE

Factory Installed options include:

Code Name Ratings Description P12 12 Pulse Field

Conversion Kit 150 - 561

Allows conversion of 6 pulse drive to a 12 pulse drive in the field.

SH Space Heater All Prevents condensation from forming inside the drive enclosure. Generally not suitable for enclosure heating in cold climates.

AP Arctic Package All Provides thermostatically controlled enclosure heaters and ventilation control for operation to -40°C (-40°F).

DP Desert Package All Provides added protection to reduce solar heating in desert applications.

AOC Analog Output Converter

All Converts the two 0 to +/- 10V Analog Outputs on Vector VII to 4 to 20 ma outputs.

DIC Digital Input Converter All Converts the seven 24 V DC Digital Inputs on Vector VII to 120 VAC Digital Inputs.

TVSS Transient Voltage Surge Suppression

All Provides additional (very robust) protection against voltage transients and surges.

PJB Power Junction Box All For added convenience all drive power connections (3-phase drive input and motor output plus a ground connection) are wired to terminal blocks in a junction box mounted on the side of the drive enclosure.

TBX Terminal Block With Oversized Terminals

All Provides Customer I/O Interface terminal block with larger than standard terminals.

VCS RTU RTU for SPS Use ALL Provides Additional AI / AO and DI / DO ES E-Stop All Provides emergency stop of drive. DSI DownHole Sensor

Interface All Provides interface to SmartGuard® downhole

sensor via drive Operator Control Panel. COMM1 Wireless Router

Communications All Provides remote user interface to drive via a

wireless computer connection. COMM2 Satellite Interface All Provides SCADA interface to the drive via

satellite. ETI Ethernet Interface ALL Provides Interface from drive to Ethernet

system. SST Stainless Steel

Construction All Provides corrosion resistance in adverse

operating conditions such as offshore platforms. BGP Brass Gland Plate ALL For Offshore / Marine Use CE CE Certification 105-561 Complies with European Union Certification

UL / CUL UL Certification CUL Certification

105-561 NVSG

Complies with Underwriters Laboratory Requirements for United States and Canada

Consult Factory for other options.

Page 265: Wood Group ESP Catalogue

© Wood Group-ESP 2009 15

MANUFACTURER QUALIFICATIONS Wood Group ESP has been a supplier of drives for many years. Our drives are installed in a variety of oilfield pumping applications, both onshore and offshore. These include Electric Submersible Pumps (ESP), Surface Pumping Systems (SPS), and Progressing Cavity Pump (PCP) applications. Wood Group ESP’s experience with a wide variety of different oilfield pumping applications has given us the unique ability to develop a specialized drive product for the markets we serve. Our drives include application specific software and a custom Operator Control Panel that provides a common, easy to use operator interface to both the drive’s parameters and the downhole or process sensors associated with the application. Wood Group ESP can provide stand alone drives for indoor or outdoor environments or we can provide complete skid mounted packages including transformers that are easy to install and transport. We can also provide a total drive solution that includes switchgear, transformers, and a modular E-House complete with environmental controls and fire suppression systems. MANUFACTURER CERTIFICATIONS Wood Group ESP is an ISO 9001 certified company. This ensures that all quality and corrective action procedures are documented and implemented to ensure the highest level of product quality. At Wood Group ESP our goal is complete customer satisfaction. GENERAL SPECIFICATIONS / OPERATING CONDITIONS / DES IGN FEATURES Input Power Requirements: The Wood Group ESP Vector VII drive is designed to accept three phase input power within a voltage range of 480 VAC, +/- 10%. Optionally the Vector VII drive can be configured to accept some other standard input voltage such as 380 VAC, +/- 10% or 400 VAC +/- 10%. The input frequency requirement of the Vector VII drive is either 50 Hz +/- 5% or 60 Hz +/- 5%. Consult factory for all voltage requirements other than 480 VAC / 60 Hz. The Vector VII drive has a 6 pulse input as standard and can also be supplied with an optional 12 pulse, or 18 pulse input rectifier for reduced Input AC line harmonics. These drive configurations will require a special input phase shifting transformer (consult factory for transformer requirements on all 12 pulse and 18 pulse applications). See harmonic mitigation section (page 30) for details on the benefits of multi-pulse drives. Electrical Noise Immunity: Noise immunity is in accordance with IEC61800-3.

Page 266: Wood Group ESP Catalogue

© Wood Group-ESP 2009 16

Output Power Characteristics: The Vector VII drive is designed to produce an adjustable voltage, adjustable frequency output to vary the speed of an AC induction motor. Output voltage is adjustable from 0 to 100% of the applied input voltage. Output frequency is adjustable from 0 hertz to 120 hertz. The inverter section produces a sine coded output waveform using proven IGBT technology. For applications requiring a sinewave output, optional Variable Sinewave Generator (VSG) technology is available. VSG technology minimizes the effects of reflected waves caused by long cable lengths. With VSG technology motors may be successfully operated using cable lengths up to 15,000 feet. Power Conditioning: An input isolation transformer is not required for protection from normal line transients. Overload Capability: Vector VII drives will produce 110% of rated output current for 1 minute. Efficiency: Vector VII drive efficiency is 97% or higher at full load and full speed. Enclosure Features:

• NEMA 3R outdoor rated. • 10 gauge welded steel construction. • Multi-stage paint process including iron phosphate wash for adhesion and white epoxy

top coat. • Lifting eyes. • Lockable door handle and flange mount external circuit breaker disconnect handle. • Door mounted Operator Control Panel - all drive adjustments can be made with the

enclosure door closed. Hardware: The Vector VII employs the following power components:

• Diode Input – 6 Pulse, 12 Pulse, and 18 Pulse configurations available. • Inverter Section with the latest generation IGBT power devices • DC bus inductor included on all ratings. • Phase to phase and phase to ground MOV protection. • Plug-in connections on printed circuit boards. • Microprocessor based inverter logic isolated from power circuits. • Operator Control Panel is common for all KVA ratings. Interface includes a large LCD

graphical display with programming keys. • Common control connections for all ratings.

Page 267: Wood Group ESP Catalogue

© Wood Group-ESP 2009 17

Control Logic: The drive is programmable or self adjusting for operation under the following conditions:

• Operate drive with motor disconnected. • Controlled shut down, with no component failure in the event of an output phase to

phase or phase to ground short circuit and annunciation of the fault condition. • Multiple programmable stop modes including - Ramp, Coast, Ramp-to-Hold, and S-curve. • Multiple acceleration and deceleration rates.

Terminal Blocks: Separate terminal blocks are provided for control and power wiring. Optional power junction boxes offer additional installation convenience. Control Inputs and Outputs: Digital Inputs: 7 programmable inputs - 24 VDC, 8 ma – sinking or sourcing logic Digital Outputs: 2 programmable dry contacts rated 250 VAC / 30 VDC @ 1A

1 fault contact - form C dry contact rated 250 VAC / 30 VDC @ 1A Analog Inputs: 2 programmable Inputs (10 bits) Analog 1 = 0 to +10 VDC – 20 K ohms Analog 2 = 0 to +10 VDC – 20 K ohms or 4 to 20 mA – 250 ohms Analog Outputs: 2 programmable outputs (10 bits) each = 0 to +10 VDC – 2 mA Analog Reference: +15 VDC source – 20 mA Logic Reference: +24 VDC source – 8 mA

Customer Interface: Digital & Analog I/O

Page 268: Wood Group ESP Catalogue

© Wood Group-ESP 2009 18

Reference Signals: The Vector VII drive is usually configured to be controlled locally using the door mounted Oper-ator Control Panel. Reference signals can also come from a remote controller when the Vector VII drive is connected to an external SCADA system. Vector VII can also be configured to follow other reference signals including analog input signals as listed below.

1. Remote potentiometer 2. 0-10 VDC

3. 4-20 ma

Loss of Reference: The Vector VII drive can be configured to compensate for loss of its external frequency command. This command is considered lost if the drive reference drops to 10% of its value in 400 ms or less. Drive loss of reference can be programmed from 0 to 100% of drive’s speed command setting. Factory default setting is 80% of speed command. Power Loss Ride Through Capability: The Vector VII drive is capable of riding through a momentary loss of input power without shutting down. Automatic Restart: The Vector VII drive can be programmed to automatically restart after a drive fault. The number of restart attempts can be programmed from 0 to 10 with a factory default setting of zero. Time between restart attempts is programmable from .5 to 600 seconds with a factory de-fault setting of 180 seconds. Jump Frequencies: Three adjustable set points that lock out continuous operation at frequencies which may pro-duce mechanical resonance are provided. Bandwidth is selectable from 0 to 20 hertz. Current Limit Programmable current limit is from 0% to 180% of drive rated output current. Acceleration / Deceleration Accel / Decel settings provide separate adjustments to allow either setting to be adjusted from 0.0 seconds to 6000.0 seconds. Minimum Frequency Limit / Fault The minimum frequency limit is set as a percentage of the command / set point frequency and may be used with PI control. If the drive senses this limit or drops below it a fault occurs and the drive will shut down.

Page 269: Wood Group ESP Catalogue

© Wood Group-ESP 2009 19

Bus Regulation DC Bus regulation is available to reduce the possibility of drive over-voltage trips due to regenerative conditions. Bus voltage is monitored and an internal regulator adjusts the drive’s output frequency to maintain bus voltage at a nominal (100%) level. Undervoltage trip occurs at 380 VDC and overvoltage trip occurs at 800 VDC. Underload Detection Enabled or disabled via programming, this feature allows the user to select the output current level that indicates the load has been lost. A programmable timing delay can also be set. Maximum time is 10 seconds. Factory default is “Disabled” and factory default time is 10 seconds. Motor Overload Protection Electronic motor overload protection is provided from both a current overload and motor overheating function. Exceeding either limit results in a trip / fault condition that will de-energize the drive. Trip time is user selectable. Fault Memory / Event Log Faults can be accessed via the event log screen. The event log contains the most current 256 events with each being time stamped with the month, day, year, hour and minute of occurrence. Any parameter changes will contain previous and current settings for user reference. Data is stored in a non-volatile memory. Adjustments The Operator Control Panel is used for all set-up, operation and adjustment settings. All adjustments are stored in a nonvolatile memory. No potentiometer adjustments are used. Communications Interface Operator Control Panel has multiple user selectable communication port assignments for See Options list on page 12 for other communication protocols that can be used with the drive. Hard Start This function allows the operator to initiate a continuous forward / reverse start of downhole equipment. Function is designed for assistance in starting equipment that is difficult to start because of “sanded in” conditions or similar circumstances. Parameters are user configurable.

Page 270: Wood Group ESP Catalogue

© Wood Group-ESP 2009 20

OPERATOR CONTROL PANEL Interface to the Vector VII drive is provided via an Operator Control Panel with integral display. The display is easily read in bright sunlight and has a backlit LCD. It shows drive operating conditions, fault indications and programming information. The Operator Control Panel is stand-ard on all drive ratings, has password protection, and provides a monitoring interface to the optional SmartGuard® downhole sensor. Data can be retrieved from the drive using a laptop computer or memory stick via the USB port directly below the Operator Control Panel. Some of its features are as follows:

• Intuitive Menu Select Screen. (See Figure 1) • Comprehensive Run Status Screen. (See Figure 2) • Operator Control Panel displays actual date and time. (See Figure 2) • Drive and well parameters are displayed in plain text. (See Figure 2) • All Monitors Screen gives snapshot of drive and downhole sensor status. (See Figure 3) • Software Embedded Recording Ammeter with 1 or 7 day format. (See Figure 4) • Trending Screen for various surface and downhole parameters. (See Figure 5) • Software Embedded Lock Out Switches. (See Figure 6) • Time Stamped Event Log (256 events). (See Figure 7) • SmartGuard downhole sensor screen. (See Figure 8) • History Logs (35 days of data). (See Figure 9) • Drive status lights showing the drive operating mode (See Figure 10) • Multiple Languages

A representation of the Operator Control Panel is shown below along with an explanation of the function keys.

Operator Control Panel and USB Port Function Key Explanations

Page 271: Wood Group ESP Catalogue

© Wood Group-ESP 2009 21

Operator Control Panel Screen Examples:

Figure 1 Figure 2

Figure 3 Figure 4

Figure 5 Figure 6

Page 272: Wood Group ESP Catalogue

© Wood Group-ESP 2009 22

Operator Control Panel Screen Examples:

Figure 7 Figure 8 History Screen This screen displays logged performance data using 20 different parameters. They are as follows.

Figure 9

Drive Outputs SmartGuard Outputs Transformer Outpu ts To Motor

Volts DC Bus Volts Intake PSI Vibration Volts Amps Heat Sink Temp. Discharge PSI Leakage Current Amps Hertz KW Intake Temp. UpHole DC Volts Analog 1 PI Control Output Motor Temp. Analog 2 Status Digital Input

Page 273: Wood Group ESP Catalogue

© Wood Group-ESP 2009 23

Operator Control Panel Screen Examples:

Status Indicator Lights The drive will display drive status information that can be seen from a distance. Drive status indicators are as follows:

• Green = Drive running. • Red = Drive stopped in ready state • Flashing Red = Drive stopped in fault state • Amber = Drive stopped in restart state. Drive

will automatically restart – but the time to restart is greater than 1 minute.

• Flashing Amber = Drive stopped in restart or standby state. Drive will automatically restart in less than 1 minute. If in standby state, the drive will restart immediately whenever the standby switch closes.

Figure 10

Start up of the Vector VII drive can be easily accomplished using basic setup parameters such as minimum and maximum frequency, acceleration and deceleration times, motor data, overload and underload limits, and other parameters. An example screen is shown below. Frequency Setup

Figure 11

Page 274: Wood Group ESP Catalogue

© Wood Group-ESP 2009 24

Operator Control Panel Screen Examples:

Alarms Setup

The Alarms Setup screen allows a logged on user to set the overload and underload limits as well as other alarm parameters. See figures 12 and 13 below.

Figure 12 Figure 13 The Vector VII drive is capable of operating as a frequency control, a current control, a pressure control, or it can be set to follow an Analog Signal from an external source. The following screens show how to configure the Vector VII drive for Frequency Control or Analog Signal Follower control. Operating / Control Mode (Frequency and Analog Foll ower)

Figure 14 Figure 15

Page 275: Wood Group ESP Catalogue

© Wood Group-ESP 2009 25

Operator Control Panel Screen Examples:

Operating / Control Mode (Pressure) An example of the pressure control mode using the internal process PI regulator is shown in Figures 16 and 17. In this example if the pressure measured at the pump discharge falls below the set point, the drive will speed up and try to restore the pressure (up to the maximum frequency defined on the Frequency Setup screen – Figure 17). If the pressure exceeds the set point, the drive will slow to reduce the pressure (down to the minimum frequency defined on the Frequency Setup screen). The drive will adjust the frequency in the opposite direction if the intake pressure is used as a reference. Protection is provided for a loss of feedback or reference signal. Process control can be enabled or disabled with a hardwire input.

Figure 16 Figure 17 Current Control Mode This allows the drive to operate with a constant current reference point and would primarily be used for gassy wells.

Figure 18

Page 276: Wood Group ESP Catalogue

© Wood Group-ESP 2009 26

Operator Control Panel Screen Examples: Drive I/O Setup The user can easily determine the state of I/O settings at a glance by using this screen. S1 through S7 are user digital inputs, M1-M2 along with M3-M4 are digital outputs, A1 and A2 are analog inputs.

Figure 19

Communications (Comm) Setup A logged on user can define SCADA Modbus address and assign how the communication ports may be used. Comm port 2 is the default setting for external SCADA system communications.

Figure 20

Page 277: Wood Group ESP Catalogue

© Wood Group-ESP 2009 27

Operator Control Panel Screen Examples:

Miscellaneous Setup This screen allows a logged on user to configure various parameters. For example, enable or disable downhole sensor communications (SmartGuard), set output transformer winding ratio to allow calculation of downhole motor voltage and current, or external fault settings status selection.

Figure 21

Maintenance Screen

Logged on user can perform various functions such as checking or updating all drive parameters, resetting prior parameter settings to factory defaults, upgrading firmware, or downloading various logs and the internal digital recording ammeter data to a memory stick. Additionally, if several drives will have the same operating parameters these settings from the first drive can be downloaded to a memory stick and uploaded to the other drives via the USB port. This facilitates getting all drives running.

Figure 22

Page 278: Wood Group ESP Catalogue

© Wood Group-ESP 2009 28

Operator Control Panel Screen Examples:

Last Fault Screen User / operator can easily view current drive condition and when last fault occurred.

Figure 23

Hard Start Screen

User selectable for situations where pump may be “sanded in” and hard to start. This allows submersible equipment to oscillate at pre-determined intervals and ramp up to set point speed after equipment becomes free.

Figure 24

Page 279: Wood Group ESP Catalogue

© Wood Group-ESP 2009 29

Surface Pumping Systems (SPS™) Vector® VII drives have the capability of communicating serially with the VCS® RTU. This allows for expanded I/O and use of existing VCS® RTU SPS software / automation routines for control in surface pumping applications. Drive Frequency is controlled by the fully programmable internal PID loop of the RTU. Dedicated I/O points commonly used with SPS applications and other fully programmable I/O points reside on the RTU. It is recommended that this RTU option be used to control startup sequencing. Twelve digital I/O (120 VAC standard, 24 VDC optional) and 10 analog I/O (8 analog inputs (4-20 ma standard, 0-10 VDC optional) and 2 analog outputs (0-10 VDC) are available. These are in addition to the 9 digital I/O and 4 analog I/O on the Vector VII drive (see page 7). The following flow chart illustrates a typical SPS system start up sequence. Also shown is the VCS RTU and typical SPS skid system.

Page 280: Wood Group ESP Catalogue

© Wood Group-ESP 2009 30

INPUT HARMONIC MITIGATION Excessive AC Line Harmonics can cause problems in the AC power system including the overheating of power system components such as transformers, circuit breakers, and panel boards. It can also cause nuisance tripping of circuit breakers, and the inadvertent transfer of electrical noise to critical loads such as communications systems, computers, and process control equipment. Drives are a potential source of AC line harmonics and control of those harmonics reflected back to the power distribution system may be an important consideration in the selection of a drive. Multi-pulse drives can help you maintain

Vector VII drives may be ordered with 6 Pulse (standard), 12 Pulse, and 18 Pulse input rectifier assemblies. The 6 pulse input rectifier assembly is generally accepted as the industry standard for low voltage AC drives. It is very simple, relatively inexpensive, and requires no additional (phase shifting) transformer for proper operation. When the control of Input AC line harmonics is important, 12 Pulse and 18 Pulse input rectifier assemblies are often selected. These drive configurations (12 Pulse and 18 Pulse) are sometimes referred to as “multi-pulse” drives. The input rectifier assembly for 12 pulse and 18 pulse drives is more complex than the input rectifier assembly for a 6 pulse drive – in fact, a 12 pulse input rectifier assembly consists of two 6 pulse rectifier bridges operating in parallel and an 18 pulse input rectifier assembly consists of three 6 pulse rectifier bridges operating in parallel. The added cost of these input rectifier assemblies is generally not that significant in the overall cost of the drive. The major cost differential (and it can be quite significant) between a 6 pulse drive and a 12 pulse or 18 pulse drive is the added cost of the Phase Shift Transformer that is required for “multi-pulse” operation. The multi-pulse phase shift transformers have conventional three phase inputs. The output of a 12 pulse phase shift transformer is a six wire connection and the output of an 18 pulse phase shift transformer is a nine wire connection. Twelve and Eighteen Pulse drives introduce lower levels of AC line harmonics into the power system than conventional Six Pulse Drives. Typical measurements for these various different front end configurations are shown below. These values should be used for estimating purposes only as measured results can vary based on line impedance, other linear loads on the feeder transformer, pre-existing harmonics due to other non-linear loads on the supply, and other factors. In general 12 pulse drives provide substantial reduction in power line harmonics over 6 pulse units and 18 pulse drives provide IEEE-519 compliance.

Category

6-Pulse Drive

12-Pulse Drive

18-Pulse Drive

Current THD 30-35% 6.5-9.5% 4.5-5%

Power Factor .92-.95 .97-.98 .98-.99

DPF .95-.97 .96-.98 .98-.99

K-Factor 3.0-5.0 2.0-3.0 1.0-2.0

Page 281: Wood Group ESP Catalogue

© Wood Group-ESP 2009 31

Multi-Pulse Examples: 12 Pulse Drive – Basic Schematic

18 Pulse Drive – Basic Schematic

Page 282: Wood Group ESP Catalogue

© Wood Group-ESP 2009 32

OUTPUT HARMONIC MITIGATION Wood Group-ESP developed VSG (Variable Sinewave Generator) technology specifically for Electric Submersible Equipment. It is a proprietary solution that provides a virtually pure sinewave output to downhole equipment and elimination of reflected wave phenomenon (motor spiking). Motor spiking can quickly destroy motor insulation and cause equipment failure. By virtue of VSG performance characteristics submersible motor heating caused by output harmonics is dramatically reduced. Typically the industry “rule of thumb” is that for every 10º C heat increase over the motor design point insulation life of the equipment decreases by 50%. Harmonics generate additional heat and mitigation of them can contribute to increased equipment life and in some cases lower operating expenses. VSG technology is effective with cable lengths up to 15,000 feet.

Failed motor winding – Motor Spiking

Vector VII with VSG – Virtually Pure Sinewave Outpu t

Page 283: Wood Group ESP Catalogue

© Wood Group-ESP 2009 33

Grounding and Bonding Correct system grounding and equipment bonding is required to ensure proper operation of equipment during both normal operation and underfault conditions. Grounding and bonding conductors provide a path to ground for lethal fault currents and voltages. Failure to correctly ground and bond equipment can lead to equipment damage and personnel injury or death. Grounding applies to the main service connection to ground. Service transformer wye-point and enclosures, including the service disconnect switch, must be connected to a common ground conductor and grounding electrodes (Refer to local electrical authority for approved grounding electrodes and methods in your area). System ground resistance should not exceed 25 Ohms to ground and ideally be between 1-5 Ohms to ground. Ground resistance checks should only be made by qualified electrical inspection agencies. Bonding applies to all other electrical equipment and raceways. A bonding conductor must be connected from the main grounding electrodes to all enclosures, junction boxes, buildings, electrical pipes, and the wellhead. This equipment provides an internal ground connection for the bonding conductor. This connector is connected to the internal ground bus of the enclosure. A typical 3/60/480 VAC ESP installation is shown below.

Page 284: Wood Group ESP Catalogue

© Wood Group-ESP 2009 34

GENERATOR REQUIREMENTS

Generators are often used as a source of power for oil field applications. When drives are operated from a generator, specific operational problems can occur unless the overall power system is properly designed for the application. Generators almost always have a higher source impedance than that of a typical electrical utility. Therefore, the non-linear current drawn by a drive tends to distort the generator output voltage waveform more than it would distort the voltage waveform of the electric utility. This distortion or “flat topping” of the generator output voltage waveform can confuse the generator’s voltage regulator and lead to a loss of voltage control and wide swings in generator output voltage. Because of this, the control of AC line harmonics is very important in generator applications. Whenever possible avoid situations where a generator is required to feed a load that consists mostly of non-linear loads (such as drives). It is best if the percentage of non-linear load can be kept to less than 20% of the total load connected to the generator. Often this is not possible. When a generator is used in a remote location as a power provider for a single drive or a group of drives, the percentage of non-linear load connected to the generator may approach 100%. In these situations, the following guidelines should be followed:

1. Use a multi-pulse drive (12 pulse or 18 pulse) to significantly reduce the AC line harmonics – this is usually your best approach.

2. Oversize the alternator component of the generator to lower the relative source

impedance of the generator – doubling the size of the alternator will reduce the relative source impedance by 50%. While this may be helpful in applications where the percent-age of non-linear load is less than 50% of the total connected load it will probably have little or no effect in applications where non-linear loads constitute a high percentage of the connected load.

3. Do not rely on the addition of AC line reactors between the generator and the drive to fix

the problem – they simply add line impedance which often makes the problem worse. 4. Be very careful when applying harmonic filters to a generator system – passive harmonic

filters generally consist of reactors and capacitors. The reactors add line impedance which usually does not solve your problem and the capacitors can cause the power factor to become leading under lightly loaded conditions. In general, generators do not like a leading power factor load – it confuses the generator’s voltage regulator and leads to a loss of voltage control and wide swings in generator output voltage.

When Vector VII drives will be operated from a generator source it is best to contact Wood Group ESP with the following information:

1. Generator information – Manufacturer, Model #, Output Voltage, Kw, KVA, and Impedance.

2. Load Information – This information should be in the form of a power one line diagram

with complete information about all connected loads - linear and non-linear. It should also include information about any line reactors, transformers, harmonic filters, and power factor correction equipment included on the system.

Page 285: Wood Group ESP Catalogue

© Wood Group-ESP 2009 35

Generator supplied power systems have the same requirements for grounding and bonding as utility supplied systems. Grounding electrodes must be installed and a common bonding conductor must be connected to all equipment and buildings. When the generator system does not incorporate a wye-point for connection to the system ground, then an isolation transformer is required between the generator and input to the VSD. This provides protection from floating voltages, and provides a wye-point for connection to the ground system. Non compliance with the above guidelines will result in poor performance and / or equipment failure. A typical 3/60/480 VAC generator ESP installation is shown below.

Vented Junction Box Detail

See Application Brief 01010 and Drawing 146261 for additional references.

Page 286: Wood Group ESP Catalogue

© Wood Group-ESP 2009 36

DIMENSIONS & WEIGHTS - VECTOR VII WITHOUT VSG

REFERENCE ONLY

“A” and “B” Frames “C” and “D” Frames

HEIGHT (INCHES / MM)

WIDTH (INCHES / MM)

DEPTH (INCHES / MM)

FRAME

KVA

H W W1 D D1

WEIGHT (POUNDS / KG)

150 944 / 429 200 1025 / 465

A

253

82 / 2083

48 / 1220

36 / 915

42 / 1067

36 / 915 1100 / 499

344 1281 / 582 428 1325 / 601

B

561

88 / 2236

57 / 1448

48 /

1220

40 / 1016

36 / 915 1600 / 726

750 850

C

1000

88 / 2236

99 / 2515

72 /

1829

53 / 1347

48 / 1220

4723 / 2143

1200 1400

D

1500

88 / 2236

117 / 2972

90 /

2286

53 / 1347

48 / 1220

4800 / 2178

Note: VSG is required for all ESP applications.

Page 287: Wood Group ESP Catalogue

© Wood Group-ESP 2009 37

DIMENSIONS & WEIGHTS - VECTOR VII WITH VSG

REFERENCE ONLY

“A” and “B” Frames “C” and “D” Frames

HEIGHT (INCHES / MM)

WIDTH (INCHES / MM)

DEPTH (INCHES / MM)

FRAME

KVA

H W W1 D D1

WEIGHT (POUNDS / KG)

150 1320 / 599 200 1400 / 635

A

253

82 / 2083

48 / 1220

36 / 915

42 / 1067

36 / 915 1470 / 667

344 1781 / 808 428 1825 / 828

B

561

103 / 2616

57 / 1448

48 / 1220

40 / 1016

36 / 915 2100 / 953

750 850

C

1000

103 / 2616

99 / 2515

72 / 1829

53 / 1347

48 /

1220

5623 / 2551

1200 1400

D

1500

103 / 2616

117 / 2972

90 / 2286

53 / 1347

48 /

1220

6000 / 2722

Note: VSG is required for all ESP applications.

Page 288: Wood Group ESP Catalogue

© Wood Group-ESP 2009 38

CORPORATE OFFICE &

MANUFACTURING WORLDWIDE SALES

& OPERATIONS OUTSIDE U.S. SALES & SERVICE

5500 S.E. 59th St (73135) P.O. Box 15070 (73155) Oklahoma City, OKlahoma, USA Tel 405-670-1431 Toll free 800-723-3771 Fax 405-670-5463

19416 Park Row, Suite 100 Houston, Texas 77084 USA Tel 281-492-5100 Fax 281-492-8107

U.S. SALES & SERVICE

GULF COAST Houston, Texas Tel: 281-492-5100 Fax: 281-492-8107 Laurel, Mississippi Tel: 601-649-2030 Toll free: 800-488-9260 Fax: 601-649-8819 MID CONTINENT Oklahoma, City, Oklahoma* Tel: 405-671-1431 Toll free: 800-723-3771 Fax: 405-673-5463 Purcell, Oklahoma Tel: 405-527-1566 Toll free: 800-256-5058 Fax: 405-527-7161 PERMIAN BASIN Artesia, New Mexico Tel: 505-746-4614 Fax: 505-746-4519 Hobbs, New Mexico Tel: 505-392-7999 Fax: 505-392-8190 *Manufacturing Facility in addition to Sales & Service.

Andrews, Texas Tel: 432-523-9701 Fax: 432-523-9700 Midland, Texas * Tel: 432-699-7401 Toll free: 800-749-7402 Fax: 432-699-4159 Snyder, Texas Tel: 325-573-9325 Fax: 325-573-1616 ROCKY MOUNTAIN / PACIFIC Denver, Colorado Tel: 303-350-2111 Toll free: 800-535-0310 Fax: 303-350-2112 Baker, Montana Toll free: 800-535-0306 Fax: 307-234-4497 Casper, Wyoming * Tel: 307-234-4495 Toll free: 800-535-0306

Fax: 307-234-4497

CANADA Brooks, Alberta Tel: 403-501-5822 Fax: 403-501-5823 Calgary, Alberta Tel: 403-263-7166 Fax: 403-263-7211 Leduc, Alberta * Tel: 780-955-2165 Toll free: 888-586-8909 Fax: 780-955-9487 ASIA / PACIFIC Tanggu, China Tel: +86-22-6691-4650 Jakarta, Indonesia Tel: +62-21-8370-2455 Fax: +62-21-831-2456 Singapore Tel: +65-6396-3626 Fax: +65-6396-5362 Bangkok, Thailand Tel: +66-2722-2389 Fax: +66-2722-0775 RUSSIA / CIS Moscow, Russia Tel: +7-495-937-6641 Fax: +7-495-937-6642 Nizhnevartovsk, Russia * Tel: +7-3466-416-195 Fax: +7-3466-416-295 EUROPE / AFRICA Chad, Africa Tel: +235-626-3279 Fax: +235-41723 Libya, North Africa Tel: +218-21-582-218-21-484-2093

Tunisia, Africa Tel: +216-7169-2281 Fax: +216-7169-2281 Aberdeen, Scotland Tel: +44-1224-85-1000 Fax: +44-1224-85-1474 LATIN AMERICA Buenos Aires, Argentina Tel: +54-4812-2329 Fax: +54-4812-2073 Chubut, Argentina * Tel: +54-297-446-8254 Fax: +54-297-446-8377 Bogota, Colombia Tel: +57-1-621-2425 Fax: +57-1-621-2264 Quito, Ecuador Tel: 593-2-2428-211 Fax: 593-2-2428-213 El Tigre, Venezuela Tel: +58-283-241-7151 Fax: +58-283-241-8613 Maracaibo, Venezuela * Tel: +58-261-200-9200 Fax: +58-261-7-361993 MIDDLE EAST Al Shark, Kuwait Tel: 965-398-3639-2810 Fax: 965-398-3639-2811 Shati Al Qurum, Oman Tel: 968-605501 Fax: 968-605784 Dubai, UAE * Tel: +971-4-883-7595 Fax: +971-4-883-7579

08-15-2009

Woo d Group ESP World -Wide Operations

Saudi Arabia Oman UAE Yemen

Venezuela Colombia Argentina Brazil Ecuador

Guatemala

Canada Calgary Nisku Brooks U.S.A. Casper, WY Denver, CO Midland, TX Hobbs, NM Purcell, OK OKC, OK

Moscow Nizhnevartovsk

Nigeria Egypt Algeria Chad Libya

Singapore Indonesia Australia Vietnam Thailand China Japan

Business Regions South America EMA North America Europe, Middle East, Africa

NNoorrtthh AAmmeerr iiccaa

CCeenntt rraall AAmmeerr iiccaa

UUKK

AAffrr iiccaa

RRuussssiiaa

AAssiiaa PPaaccii ff ii cc

MMiiddddllee EEaasstt

SSoouutthh AAmmeerr iiccaa

Page 289: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-1

TRANSFORMERS VARIABLE SPEED DRIVE TRANSFORMER – 3 PHASE

DIMENSIONS H X D X W WEIGHT SIZE

KVA PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

67 480 480-960 DELTA 831-1663 WYE 47 x 35 x 41 119 x 89 x 104 2390 1084 136829

100 480 750-1258 DELTA 1300-2160 WYE 54 x 37 x 41 137 x 90 x 104 2530 1148 136828

130 480 750 – 1497 DELTA 1299 – 2600 WYE 56 x 46 x 44 142 x 117 x

112 2850 1293 136827

130 480 750 – 1550 DELTA 1299 – 2685 WYE 50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390

150 480 800-1559 DELTA 1386 - 2700 WYE 68 x 46 x 44 173 x 117 x

112 3740 1696 136683

200 480 1100 – 2200 DELTA 1905 – 3811 WYE 53 X 43 X 51.5 135 x 109.x

131 3530 1601 1057017

210 480 1100 – 2200 DELTA 1905 – 3810 WYE 60 x 48 x 50 152 x 122 x

127 3850 1746 136826

250 415 950-1900 DELTA 1650-3300 WYE 78 x 52 x 48 198 x 132 x

122 4220 1914 127729

250 480 1100-2200 DELTA 1905-3810 WYE 78 x 52 x 48 198 x 132 x

122 4220 1914 136682

260 480 1100 – 2200 DELTA 1905 – 3811 WYE 60 X 52 X 48 152 x 132 x

122 4220 1914 136825

350 480 1100 – 2200 DELTA 1905 – 3811 WYE 74 x 54 x 50 188 x 137 x

127 6540 2967 136824

355 480 1100 – 2200 DELTA 1905 – 3811 WYE

57.5 X 45 X 53.5

146 x 114 x 136 5350 2427 1054386

400 415 950-1900 DELTA 1650-3300 WYE 61 x 61 x 54 155 x 155 x

137 6675 3028 127961

400 480 1109-2166 DELTA 1921-3732 WYE 75 x 61 x 54 191 x 155 x

137 6675 3028 136823

400 480 1100 – 2200 DELTA 1905 – 3811 WYE 70 X 42 X 62 178 x 107 x

158 4500 2041 1057416

450 480 1100-2200 DELTA 1905-3810 WYE 78 x 46 x 58 198 x 117 x

147 8175 3708 136681

520 480 1100 – 2200 DELTA 1905 – 3811 WYE 78 x 65 x 54 198 x 165 x

137 8300 3765 136822

750 480 1300-2601 DELTA 2252-4505 WYE 82 x 67 x 60 208 x 170 x

152 9326 4230 136680

750 480 1320-2640 DELTA 2286-4572 WYE 81 x 67 x 62 206 x 170 x

157 9800 4445 136821

850 480 1400-2800 DELTA 2424-4850 WYE 82 x 68 x 62 208 x 173 x

157 11200 5080 136820

1000 480 1400-2800 DELTA 2424-4850 WYE 86 x 67 x 64 218 x 170 x

163 11500 5216 136819

Page 290: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009

TRANSFORMERS SPECIALTY TRANSFORMER – 3 PHASE

DIMENSIONS H X D X W WEIGHT SIZE

KVA PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

125 6000 1100-2200 DELTA 1905-3810 WYE 56 x 45 x 46 142 x 114 x

117 3275 1486 136253

150 13800 800-1559 DELTA 1386-2700 WYE 78 x 46 x 44 198 x 117 x

112 3927 1781 136615

150 34500 800-1559 DELTA 1386–2700 WYE 78 x 46 x 44 198 x 117 x

112 3927 1781 136614

250 13800 1100-2200 DELTA 2200-3810 WYE 70 x 52 x 48 178 x 132 x

122 4431 2010 136675

250 34500 1100-2200 DELTA 2200-3810 WYE 78 x 52 x 50 198 x 132 x

127 4642 2106 136674

450 13800 1100-2200 DELTA 2200-3810 WYE 88 x 65 x 54 224 x 165 x

137 8450 3833 136677

450 34500 1100-2200 DELTA 2200-3810 WYE 96 x 65 x 54 244 x 165 x

137 8650 3924 136676

500 13800 1100-2200 DELTA 1905-3811 WYE 76 x 80 x 55 193 x 203 x

140 6502 2949 136198

750 13800 1100-2200 DELTA 2200-3810 WYE 90 x 67 x 60 229 x 170 x

152 9792 4442 136679

750 34500 1100-2200 DELTA 2200-3810 WYE 90 x 67 x 60 229 x 170 x

152 10307 4675 136678

Page 291: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-3

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 480/831 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731 – 2510 ex ∆ 37.5 2400/4160 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 7200/12470 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 12470 ∆*

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 14400/24940 Y

831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 19920/34500 grd

Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 50 480/831 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 2400/4160 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 7200/12470 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 12470 ∆*

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 14400/24940 Y

831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 19920/34500 grd

Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 292: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

480 – 1920 ∆ 1731- 2510 ex ∆ 75 480/831 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731 – 2510 ex ∆ 75 2400/4160 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 7200/12470 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 12470 ∆*

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 14400/24940 Y

831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 429

480 – 1920 ∆ 1731- 2510 ex ∆ 75 19920/34500

grd Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 429

480 – 1920 ∆ 1731- 2510 ex ∆ 100 480/831 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 2400/4160 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 7200/12470 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 12470 ∆*

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 14400/24940 Y

831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

480 – 1920 ∆ 1731- 2510 ex ∆ 100 19920/34500

grd Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 293: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-5

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 2400/4160 Y

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 7200/12470 Y

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 12470 ∆

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 14400/24940 Y

1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 19920/34500 Y

1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 7200/12470 Y

1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 12470 ∆

1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 14400/24940 Y

1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 19920/34500 Y

1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1700 771

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 294: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009

TRANSFORMERS SINGLE PHASE FACT 225

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 2400/4160 Y

7200/12470 Y 831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731 – 2510 ex ∆ 37.5 7200/12470 Y

14400/24940 Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 50 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 75 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 428

480 – 1920 ∆ 1731- 2510 ex ∆ 75 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 428

480 – 1920 ∆ 1731- 2510 ex ∆ 100 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

480 – 1920 ∆ 1731- 2510 ex ∆ 100 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 295: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-7

TRANSFORMERS SINGLE PHASE FACT 225

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 2400/4160 Y

7200/12470 Y 1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 7200/12470 Y

14400/24940 Y 1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 14400/24940 Y

19920/34500 grd Y 1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 2400/4160 Y

7200/12470 Y 1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1750 793

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 7200/12470 Y

14400/24940 Y 1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1750 793

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 14400/24940 Y

19920/34500 grd Y 1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1750 793

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 296: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-1

TRANSFORMERS VARIABLE SPEED DRIVE TRANSFORMER – 3 PHASE

DIMENSIONS H X D X W WEIGHT SIZE

KVA PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

67 480 480-960 DELTA 831-1663 WYE 47 x 35 x 41 119 x 89 x 104 2390 1084 136829

100 480 750-1258 DELTA 1300-2160 WYE 54 x 37 x 41 137 x 90 x 104 2530 1148 136828

130 480 750 – 1497 DELTA 1299 – 2600 WYE 56 x 46 x 44 142 x 117 x

112 2850 1293 136827

130 480 750 – 1550 DELTA 1299 – 2685 WYE 50.5 x 37 x 42 128 x 94 x 107 2850 1293 1057390

150 480 800-1559 DELTA 1386 - 2700 WYE 68 x 46 x 44 173 x 117 x

112 3740 1696 136683

200 480 1100 – 2200 DELTA 1905 – 3811 WYE 53 X 43 X 51.5 135 x 109.x

131 3530 1601 1057017

210 480 1100 – 2200 DELTA 1905 – 3810 WYE 60 x 48 x 50 152 x 122 x

127 3850 1746 136826

250 415 950-1900 DELTA 1650-3300 WYE 78 x 52 x 48 198 x 132 x

122 4220 1914 127729

250 480 1100-2200 DELTA 1905-3810 WYE 78 x 52 x 48 198 x 132 x

122 4220 1914 136682

260 480 1100 – 2200 DELTA 1905 – 3811 WYE 60 X 52 X 48 152 x 132 x

122 4220 1914 136825

350 480 1100 – 2200 DELTA 1905 – 3811 WYE 74 x 54 x 50 188 x 137 x

127 6540 2967 136824

355 480 1100 – 2200 DELTA 1905 – 3811 WYE

57.5 X 45 X 53.5

146 x 114 x 136 5350 2427 1054386

400 415 950-1900 DELTA 1650-3300 WYE 61 x 61 x 54 155 x 155 x

137 6675 3028 127961

400 480 1109-2166 DELTA 1921-3732 WYE 75 x 61 x 54 191 x 155 x

137 6675 3028 136823

400 480 1100 – 2200 DELTA 1905 – 3811 WYE 70 X 42 X 62 178 x 107 x

158 4500 2041 1057416

450 480 1100-2200 DELTA 1905-3810 WYE 78 x 46 x 58 198 x 117 x

147 8175 3708 136681

520 480 1100 – 2200 DELTA 1905 – 3811 WYE 78 x 65 x 54 198 x 165 x

137 8300 3765 136822

750 480 1300-2601 DELTA 2252-4505 WYE 82 x 67 x 60 208 x 170 x

152 9326 4230 136680

750 480 1320-2640 DELTA 2286-4572 WYE 81 x 67 x 62 206 x 170 x

157 9800 4445 136821

850 480 1400-2800 DELTA 2424-4850 WYE 82 x 68 x 62 208 x 173 x

157 11200 5080 136820

1000 480 1400-2800 DELTA 2424-4850 WYE 86 x 67 x 64 218 x 170 x

163 11500 5216 136819

Page 297: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009

TRANSFORMERS SPECIALTY TRANSFORMER – 3 PHASE

DIMENSIONS H X D X W WEIGHT SIZE

KVA PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

125 6000 1100-2200 DELTA 1905-3810 WYE 56 x 45 x 46 142 x 114 x

117 3275 1486 136253

150 13800 800-1559 DELTA 1386-2700 WYE 78 x 46 x 44 198 x 117 x

112 3927 1781 136615

150 34500 800-1559 DELTA 1386–2700 WYE 78 x 46 x 44 198 x 117 x

112 3927 1781 136614

250 13800 1100-2200 DELTA 2200-3810 WYE 70 x 52 x 48 178 x 132 x

122 4431 2010 136675

250 34500 1100-2200 DELTA 2200-3810 WYE 78 x 52 x 50 198 x 132 x

127 4642 2106 136674

450 13800 1100-2200 DELTA 2200-3810 WYE 88 x 65 x 54 224 x 165 x

137 8450 3833 136677

450 34500 1100-2200 DELTA 2200-3810 WYE 96 x 65 x 54 244 x 165 x

137 8650 3924 136676

500 13800 1100-2200 DELTA 1905-3811 WYE 76 x 80 x 55 193 x 203 x

140 6502 2949 136198

750 13800 1100-2200 DELTA 2200-3810 WYE 90 x 67 x 60 229 x 170 x

152 9792 4442 136679

750 34500 1100-2200 DELTA 2200-3810 WYE 90 x 67 x 60 229 x 170 x

152 10307 4675 136678

Page 298: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-3

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 480/831 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731 – 2510 ex ∆ 37.5 2400/4160 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 7200/12470 Y

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 12470 ∆*

831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 14400/24940 Y

831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 19920/34500 grd

Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 50 480/831 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 2400/4160 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 7200/12470 Y

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 12470 ∆*

831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 14400/24940 Y

831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 19920/34500 grd

Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 299: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

480 – 1920 ∆ 1731- 2510 ex ∆ 75 480/831 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731 – 2510 ex ∆ 75 2400/4160 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 7200/12470 Y

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 12470 ∆*

831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 14400/24940 Y

831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 429

480 – 1920 ∆ 1731- 2510 ex ∆ 75 19920/34500

grd Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 429

480 – 1920 ∆ 1731- 2510 ex ∆ 100 480/831 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 2400/4160 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 7200/12470 Y

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 12470 ∆*

831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 14400/24940 Y

831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

480 – 1920 ∆ 1731- 2510 ex ∆ 100 19920/34500

grd Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 300: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-5

TRANSFORMERS SINGLE PHASE FACT 125

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 2400/4160 Y

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 7200/12470 Y

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 12470 ∆

1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 14400/24940 Y

1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 19920/34500 Y

1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 7200/12470 Y

1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 12470 ∆

1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 14400/24940 Y

1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 19920/34500 Y

1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1700 771

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 301: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-6 Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October, 2009

TRANSFORMERS SINGLE PHASE FACT 225

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 2400/4160 Y

7200/12470 Y 831 – 3325 Y

45 x 23 x 26

114 x 58 x 66 605 274

480 – 1920 ∆ 1731 – 2510 ex ∆ 37.5 7200/12470 Y

14400/24940 Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 37.5 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

50 x 23 x 26

127 x 58 x 66 635 288

480 – 1920 ∆ 1731- 2510 ex ∆ 50 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 23 x 26

124 x 58 x 66 710 322

480 – 1920 ∆ 1731- 2510 ex ∆ 50 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 50 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 23 x 26

137 x 58 x 66 750 340

480 – 1920 ∆ 1731- 2510 ex ∆ 75 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 28 x 30

124 x 71 x 76 890 404

480 – 1920 ∆ 1731- 2510 ex ∆ 75 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 428

480 – 1920 ∆ 1731- 2510 ex ∆ 75 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 28 x 30

137 x 71 x 76 945 428

480 – 1920 ∆ 1731- 2510 ex ∆ 100 2400/4160 Y

7200/12470 Y 831 – 3325 Y

49 x 33 x 30

124 x 84 x 76 975 442

480 – 1920 ∆ 1731- 2510 ex ∆ 100 7200/12470 Y

14400/24940 Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

480 – 1920 ∆ 1731- 2510 ex ∆ 100 14400/24940 Y

19920/34500 grd Y 831 – 3325 Y

54 x 33 x 30

137 x 84 x 76 1035 469

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 302: Wood Group ESP Catalogue

Wood Group ESP, Inc.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Transformers - Copyright Wood Group ESP, Inc. - October , 2009 Page-7

TRANSFORMERS SINGLE PHASE FACT 225

DIMENSIONS H X D X W WEIGHT KVA

** PRIMARY

VOLTS SECONDARY

VOLTAGE RANGE Inches CM Lbs. Kgs.

PART NUMBER

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 2400/4160 Y

7200/12470 Y 1386 - 5543 Y

54 x 33 x 34

137 x 84 x 86 1645 746

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 7200/12470 Y

14400/24940 Y 1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 167 14400/24940 Y

19920/34500 grd Y 1386 - 5543 Y

58 x 33 x 34

147 x 84 x 86 1700 771

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 2400/4160 Y

7200/12470 Y 1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1750 793

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 7200/12470 Y

14400/24940 Y 1386 - 5543 Y

54 x 42 x 34

137 x 107 x 86 1750 793

800 – 3200 ∆ 2884 - 4233 ex ∆ 200 14400/24940 Y

19920/34500 grd Y 1386 - 5543 Y

58 x 42 x 34

147 x 107 x 86 1750 793

*- Primaries for other delta voltages available upon request. ** - Full KVA capacity at all tap positions without exceeding 65 Degrees C Rise.

Page 303: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.

G 513 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TG4000) G0120 Motor Group

5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1

11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1

18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1

25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1

32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1

38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1

45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1

52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1

59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1

65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1

73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1

79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1

86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1

92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1

100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1

104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1

111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1

118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1

124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1

130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1

138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1

146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1

152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1

158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1

165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1

172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1

178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1

184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable). Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 304: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.

G 513 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TG4000) G0120 Motor Group

192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1

200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1

205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1

212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1

219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1

225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1

231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1

237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1

244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1

251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1

258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1

264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1

270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1 THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable). Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 305: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE1500) E0050 Motor Group

7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1

14 E0050 CMP 14 STG 3393 4.0 14 1 1 1 1 1 1

22 E0050 CMP 22 STG 3460 5.5 14 1 1 1 1 1 1

30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1 37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1

45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1

52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1

60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1

68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1

75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1

83 E0050 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1

90 E0050 CMP 90 STG 5800 19.0 26 5 1 1 1 1 1

98 E0050 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1 104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1

112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1

120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1

128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1

136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1

143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1

150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1

158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1

166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1

173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1

180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1

188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1

196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1

204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1 THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 306: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE2700) E0080 Motor Group

7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1

14 E0080 CMP 14 STG 3393 4.0 14 1 1 1 1 1 1

22 E0080 CMP 22 STG 3460 5.5 14 1 1 1 1 1 1

30 E0080 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1

37 E0080 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1

45 E0080 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1

52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1 60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1

68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1

75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1

83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1

90 E0080 CMP 90 STG 5800 19.0 26 5 1 1 1 1 1 98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1

104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1

112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1

120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1

128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1

136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1

143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1

150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1

158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1

166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1

173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1

180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1

188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1

196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 307: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE5500) E0170 Motor Group

5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1

11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1

17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1

23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1

29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1

35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1

41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1

47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1 53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1 59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1 65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1 71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1

77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1 83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1 89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1 94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1

100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1 106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1 112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1 118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1

124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1 130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1 136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1 142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1 148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1

154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1 160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1 166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1 172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1 178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1 183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1

189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1 195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1 201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1

THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

Page 308: Wood Group ESP Catalogue
Page 309: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE7000) E0220 Motor Group

154

160

(2) 77 STG HSS (1) 83 STG + (1) 77 STG UHSS

9598 41.0 38 8

10228 42.5 38 12

10 1

11 1

1 1 1 1

1 1 1 1

166

172

(2) 83 STG UHSS (1) 89 STG + (1) 83 STG UHSS

10293 44.0 38 12

10358 45.5 38 12

11 1

11 1

1 1 1 1

1 1 1 1

178

183 189

(2) 89 STG UHSS (1) 65 STG + (2) 59 STG UHSS (2) 65 STG + (1) 59 STG UHSS

10988 47.0 38 16

11104 49.5 38 16

11734 51.0 38 20

12 1

12 1

13 1

1 1 1 1

1 1 1 1

1 1 1 1

195

201 207

(3) 65 STG UHSS (1) 71 STG + (2) 65 STG UHSS (2) 71 STG + (1) 65 STG UHSS

11799 52.5 38 20

12429 54.0 38 24

12244 55.5 38 24

13 1

14 1

14 1

1 1 1 1

1 1 1 1

1 1 1 1

213

219 225

(3) 71 STG UHSS (1) 77 STG + (2) 71 STG UHSS (2) 77 STG + (1) 71 STG UHSS

12309 57.0 38 24

13040 58.5 38 28

13106 60.0 38 28

14 1

15 1

15 1

1 1 1 1

1 1 1 1

1 1 1 1

231

237 243

(3) 77 STG UHSS (1) 83 STG + (2) 77 STG UHSS (2) 83 STG + (1) 77 STG UHSS

13172 61.5 38 28

13702 63.0 38 32

13767 64.5 38 32

15 1

16 1

16 1

1 1 1 1

1 1 1 1

1 1 1 1

249

255 261

(3) 83 STG UHSS (1) 89 STG + (2) 83 STG UHSS (2) 89 STG + (1) 83 STG UHSS

14397 66.0 38 36

14462 67.5 38 36

14527 69.0 38 36

17 1

17 1

17 1

1 1 1 1

1 1 1 1

1 1 1 1

267

272

(3) 89 STG UHSS (2) 71 STG + (2) 65 STG UHSS

15257 70.5 38 40

15372 73.0 38 40

18 1

18 1

1 1 1 1

1 1 1 1

THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Page 310: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ7500) J0240 Motor Group

2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1

6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1

9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1

12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1

15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1

19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1

22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1

25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1

29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1

32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1

35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1

39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1

42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1

45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1

48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1

50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1

54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1

58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1

64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1

70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1

74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1

78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1

81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1

84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 311: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ7500) J0240 Motor Group

87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1

90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1

93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1

96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1

99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1

102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1

105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1

109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1

113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1

117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1

120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14 THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

1 1 1 1

www.woodgroup-esp.com

Page-9

Page 312: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ9000) J0270 Motor Group

2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1

6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1

9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1

12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1

15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1

19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1

22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1

25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1

29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1

32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1

35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1

39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1

42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1

45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1

48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1

50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1

54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1

58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1

64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1

70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1

74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1

78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1

81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1

84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1

87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1 THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 313: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ12000) J0360 Motor Group

2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1

5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1

8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1

11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1

14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1

17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1

20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1

23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1

26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1

29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1

32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1

35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1

38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1

41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1

44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1

46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1

49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1

52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1

55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1

58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1

64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1

70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1 THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

Page 314: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.

M 950 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TM19000) M0560 Motor Group

8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1

9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1

10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1

11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1

12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1

13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1

14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1

15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1

16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1

17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1

18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1

19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1

20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1

21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1

22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1

23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1

24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1

25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1

26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1

27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1

28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1

29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1

30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1

31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1 THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 315: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.

M 950 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

6” Coated Steel

(TM24000) M0700 Motor Group

8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1

9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1

10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1

11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1

12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1

13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1

14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1

15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1

16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1

17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1

18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1

19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1

20

21

22

23

24

25

26

27

28

29

30

31

M0700 CMP A-CUT 20 STG M0700 CMP A-CUT 21 STG HSS M0700 CMP A-CUT 22 STG HSS M0700 CMP A-CUT 23 STG HSS M0700 CMP A-CUT 24 STG HSS M0700 CMP A-CUT 25 STG HSS M0700 CMP A-CUT 26 STG HSS M0700 CMP A-CUT 27 STG HSS M0700 CMP A-CUT 28 STG HSS M0700 CMP A-CUT 29 STG HSS M0700 CMP A-CUT 30 STG HSS M0700 CMP A-CUT 31 STG HSS

5464 13.6 18

6199 14.2 22

6266 14.8 22

6331 15.4 22

6398 16.0 22

6468 16.6 22

6536 17.2 22

7168 17.8 26

7232 18.4 26

7302 19.0 26

7369 19.6 26

7437 20.2 26

3 1

4 1

4 1

4 1

4 1

4 1

4 1

5 1

5 1

5 1

5 1

5 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

Page 316: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.

N 950 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

6” Coated Steel

(TN35000) N1150 Motor Group

1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1

2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1

3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1

4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1

5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1

6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1

7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1

8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1

9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1

10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1

11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1 THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 317: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.

G 513 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TG4000) G0120 Motor Group

5 G0120 CMP 05 STG 3292 2.1 14 1 1 1 1 1 1

11 G0120 CMP 11 STG 3360 3.5 14 1 1 1 1 1 1

18 G0120 CMP 18 STG 3428 4.9 14 1 1 1 1 1 1

25 G0120 CMP 25 STG 3552 6.3 14 2 1 1 1 1 1

32 G0120 CMP 32 STG 3620 7.7 14 2 1 1 1 1 1

38 G0120 CMP 38 STG 3687 9.1 14 2 1 1 1 1 1

45 G0120 CMP 45 STG 4212 10.5 18 3 1 1 1 1 1

52 G0120 CMP 52 STG 4280 11.9 18 3 1 1 1 1 1

59 G0120 CMP 59 STG 4347 13.3 18 3 1 1 1 1 1

65 G0120 CMP 65 STG 5072 14.7 22 4 1 1 1 1 1

73 G0120 CMP 73 STG 5140 16.1 22 4 1 1 1 1 1

79 G0120 CMP 79 STG 5199 17.5 22 4 1 1 1 1 1

86 G0120 CMP 86 STG 5832 18.9 26 5 1 1 1 1 1

92 G0120 CMP 92 STG 5899 20.4 26 5 1 1 1 1 1

100 G0120 CMP 100 STG 5959 21.8 26 5 1 1 1 1 1

104 (2) 52 STG 6710 23.8 30 6 1 1 1 1 1

111 (1) 59 STG + (1) 52 STG 6777 25.2 30 6 1 1 1 1 1

118 (2) 59 STG 7309 26.6 34 7 1 1 1 1 1

124 (1) 65 STG + (1) 59 STG 7369 28 34 7 1 1 1 1 1

130 (2) 65 STG 7429 29.4 34 7 1 1 1 1 1

138 (1) 73 STG + (1) 65 STG 8062 30.8 38 8 1 1 1 1 1

146 (2) 73 STG 7130 32.2 38 8 1 1 1 1 1

152 (1) 79 STG + (1) 73 STG 8129 33.6 38 8 1 1 1 1 1

158 (2) 79 STG 8913 35 38 4 9 1 1 1 1 1

165 (1) 86 STG + (1) 79 STG 8981 36.4 38 4 9 1 1 1 1 1

172 (2) 86 STG 9049 37.8 38 4 9 1 1 1 1 1

178 (1) 92 STG + (1) 86 STG 9581 39.3 38 8 10 1 1 1 1 1

184 (2) 92 STG 9648 40.8 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable). Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-1

Page 318: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with G 513 Series SP1000 Pumps.

G 513 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TG4000) G0120 Motor Group

192 (1) 100 STG + (1) 92STG 10273 42.2 38 12 11 1 1 1 1

200 (2) 100 STG 10333 43.6 38 12 11 1 1 1 1

205 (1) 73 STG + (2) 66 STG 10419 45.5 38 12 11 1 1 1 1

212 (2) 73 STG + (1) 66 STG 11052 46.9 38 16 12 1 1 1 1

219 (3) 73 STG 11120 48.3 38 16 12 1 1 1 1

225 (1) 79 STG + (2) 73 STG 11179 49.7 38 16 12 1 1 1 1

231 (2) 79 STG + (1) 73 STG 11803 51.1 38 20 13 1 1 1 1

237 (3) 79 STG 11862 52.5 38 20 13 1 1 1 1

244 (1) 86 STG + (2) 79 STG 11930 53.9 38 20 13 1 1 1 1

251 (2) 86 STG + (1) 79 STG 12563 55.3 38 24 14 1 1 1 1

258 (3) 86 STG 12631 56.7 38 24 14 1 1 1 1

264 (1) 92 STG + (2) 86 STG 13363 58.2 38 28 15 1 1 1 1

270 (2) 92 STG + (1) 86 STG 13430 59.7 38 28 15 1 1 1 1 THRUST LIMIT: 60Hz = 186 stages, 50Hz = 167 stages (for Higher Pressures, Floater Pumps may be suitable). Consider E0080 or E0170 Pumps if feasible. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-2 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 319: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE1500) E0050 Motor Group

7 E0050 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1

14 E0050 CMP 14 STG 3393 4.0 14 1 1 1 1 1 1

22 E0050 CMP 22 STG 3460 5.5 14 1 1 1 1 1 1

30 E0050 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1 37 E0050 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1

45 E0050 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1

52 E0050 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1

60 E0050 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1

68 E0050 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1

75 E0050 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1

83 E0050 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1

90 E0050 CMP 90 STG 5800 19.0 26 5 1 1 1 1 1

98 E0050 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1 104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1

112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1

120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1

128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1

136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1

143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1

150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1

158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1

166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1

173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1

180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1

188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1

196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1

204 (3) 68 STG 10270 43.5 38 12 11 1 1 1 1 1 THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-3

Page 320: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE2700) E0080 Motor Group

7 E0080 CMP 07 STG 3332 2.5 14 1 1 1 1 1 1

14 E0080 CMP 14 STG 3393 4.0 14 1 1 1 1 1 1

22 E0080 CMP 22 STG 3460 5.5 14 1 1 1 1 1 1

30 E0080 CMP 30 STG 3592 7.0 14 2 1 1 1 1 1

37 E0080 CMP 37 STG 3653 8.5 14 2 1 1 1 1 1

45 E0080 CMP 45 STG 4185 10.0 18 3 1 1 1 1 1

52 E0080 CMP 52 STG 4247 11.5 18 3 1 1 1 1 1 60 E0080 CMP 60 STG 4314 13.0 18 3 1 1 1 1 1

68 E0080 CMP 68 STG 5045 14.5 22 4 1 1 1 1 1

75 E0080 CMP 75 STG 5107 16.0 22 4 1 1 1 1 1

83 E0080 CMP 83 STG 5174 17.5 22 4 1 1 1 1 1

90 E0080 CMP 90 STG 5800 19.0 26 5 1 1 1 1 1 98 E0080 CMP 98 STG 5867 20.5 26 5 1 1 1 1 1

104 (2) 52 STG 6644 23.0 30 6 1 1 1 1 1

112 (1) 60 STG + (1) 52 STG 6711 24.5 30 6 1 1 1 1 1

120 (2) 60 STG 7243 26.0 34 7 1 1 1 1 1

128 (1) 68 STG + (1) 60 STG 7309 27.5 34 7 1 1 1 1 1

136 (2) 68 STG 7275 29.0 34 7 1 1 1 1 1

143 (1) 75 STG + (1) 68 STG 8002 30.5 38 8 1 1 1 1 1

150 (2) 75 STG 8064 32.0 38 8 1 1 1 1 1

158 (1) 83 STG + (1) 75 STG 8131 33.5 38 8 1 1 1 1 1

166 (2) 83 STG 8863 35.0 38 4 9 1 1 1 1 1

173 (1) 90 STG + (1) 83 STG 8924 36.5 38 4 9 1 1 1 1 1

180 (2) 90 STG 9450 38.0 38 8 10 1 1 1 1 1

188 (1) 98 STG + (1) 90 STG 9517 39.5 38 8 10 1 1 1 1 1

196 (2) 98 STG 9584 41.0 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 140 stages, 50Hz = 202 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-4 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 321: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE5500) E0170 Motor Group

5 E0170 CMP 05 STG 3330 2.5 14 1 1 1 1 1 1

11 E0170 CMP 11 STG 3395 4.0 14 1 1 1 1 1 1

17 E0170 CMP 17 STG 3460 5.5 14 1 1 1 1 1 1

23 E0170 CMP 23 STG 3591 7.0 14 2 1 1 1 1 1

29 E0170 CMP 29 STG 3656 8.5 14 2 1 1 1 1 1

35 E0170 CMP 35 STG 4186 10.0 18 3 1 1 1 1 1

41 E0170 CMP 41 STG 4252 11.5 18 3 1 1 1 1 1

47 E0170 CMP 47 STG 4317 13.0 18 3 1 1 1 1 1 53 E0170 CMP 53 STG 5047 14.5 22 4 1 1 1 1 1 59 E0170 CMP 59 STG 5113 16.0 22 4 1 1 1 1 1 65 E0170 CMP 65 STG 5178 17.5 22 4 1 1 1 1 1 71 E0170 CMP 71 STG 5808 19.0 26 5 1 1 1 1 1

77 E0170 CMP 77 STG 5874 20.5 26 5 1 1 1 1 1 83 E0170 CMP 83 STG 6604 22.0 30 6 1 1 1 1 1 89 E0170 CMP 89 STG 6669 23.5 30 6 1 1 1 1 1 94 (2) 47 STG 7249 26.0 34 7 1 1 1 1 1

100 (1) 53 STG + (1) 47 STG 7314 27.5 34 7 1 1 1 1 1 106 (2) 53 STG 7379 29.0 34 7 1 1 1 1 1 112 (1) 59 STG + (1) 53 STG 8010 30.5 34 8 1 1 1 1 1 118 (2) 59 STG 7076 32.0 38 8 1 1 1 1 1

124 (1) 65 STG + (1) 59 STG 8141 33.5 38 8 1 1 1 1 1 130 (2) 65 STG 8871 35.0 38 4 9 1 1 1 1 1 136 (1) 71 STG + (1) 65 STG 8936 36.5 38 4 9 1 1 1 1 1 142 (2) 71 STG 9466 38.0 38 8 10 1 1 1 1 1 148 (1) 77 STG + (1) 71 STG 9532 39.5 38 8 10 1 1 1 1 1

154 (2) 77 STG 9598 41.0 38 8 10 1 1 1 1 1 160 (1) 83 STG + (1) 77 STG 10228 42.5 38 12 11 1 1 1 1 1 166 (2) 83 STG 10293 44.0 38 12 11 1 1 1 1 1 172 (1) 89 STG + (1) 83 STG 10358 45.5 38 12 11 1 1 1 1 1 178 (2) 89 STG 10988 47.0 38 16 12 1 1 1 1 1 183 (1) 65 STG + (2) 59 STG 11104 49.5 38 16 12 1 1 1 1 1

189 (2) 65 STG + (1) 59 STG 11734 51.0 38 20 13 1 1 1 1 1 195 (3) 65 STG 11799 52.5 38 20 13 1 1 1 1 1 201 (1) 71 STG + (2) 65 STG 12429 54.0 38 24 14 1 1 1 1 1

THRUST LIMIT: 60Hz = 138 stages, 50Hz = 199 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-5

Page 322: Wood Group ESP Catalogue
Page 323: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with E 562 Series SP1000 Pumps.

E 562 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

3” Coated Steel

(TE7000) E0220 Motor Group

154

160

(2) 77 STG HSS (1) 83 STG + (1) 77 STG UHSS

9598 41.0 38 8

10228 42.5 38 12

10 1

11 1

1 1 1 1

1 1 1 1

166

172

(2) 83 STG UHSS (1) 89 STG + (1) 83 STG UHSS

10293 44.0 38 12

10358 45.5 38 12

11 1

11 1

1 1 1 1

1 1 1 1

178

183 189

(2) 89 STG UHSS (1) 65 STG + (2) 59 STG UHSS (2) 65 STG + (1) 59 STG UHSS

10988 47.0 38 16

11104 49.5 38 16

11734 51.0 38 20

12 1

12 1

13 1

1 1 1 1

1 1 1 1

1 1 1 1

195

201 207

(3) 65 STG UHSS (1) 71 STG + (2) 65 STG UHSS (2) 71 STG + (1) 65 STG UHSS

11799 52.5 38 20

12429 54.0 38 24

12244 55.5 38 24

13 1

14 1

14 1

1 1 1 1

1 1 1 1

1 1 1 1

213

219 225

(3) 71 STG UHSS (1) 77 STG + (2) 71 STG UHSS (2) 77 STG + (1) 71 STG UHSS

12309 57.0 38 24

13040 58.5 38 28

13106 60.0 38 28

14 1

15 1

15 1

1 1 1 1

1 1 1 1

1 1 1 1

231

237 243

(3) 77 STG UHSS (1) 83 STG + (2) 77 STG UHSS (2) 83 STG + (1) 77 STG UHSS

13172 61.5 38 28

13702 63.0 38 32

13767 64.5 38 32

15 1

16 1

16 1

1 1 1 1

1 1 1 1

1 1 1 1

249

255 261

(3) 83 STG UHSS (1) 89 STG + (2) 83 STG UHSS (2) 89 STG + (1) 83 STG UHSS

14397 66.0 38 36

14462 67.5 38 36

14527 69.0 38 36

17 1

17 1

17 1

1 1 1 1

1 1 1 1

1 1 1 1

267

272

(3) 89 STG UHSS (2) 71 STG + (2) 65 STG UHSS

15257 70.5 38 40

15372 73.0 38 40

18 1

18 1

1 1 1 1

1 1 1 1

THRUST LIMIT: 60Hz = 188 stages, 50Hz = 270 stages (for Higher Pressures, Floater Pumps may be suitable). Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-7

Page 324: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ7500) J0240 Motor Group

2 J0240 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1

6 J0240 CMP 06 STG 3542 4.0 14 1 1 1 1 1 1

9 J0240 CMP 09 STG 3634 5.4 14 1 1 1 1 1 1

12 J0240 CMP 12 STG 3791 6.8 14 2 1 1 1 1 1

15 J0240 CMP 15 STG 3883 8.2 14 2 1 1 1 1 1

19 J0240 CMP 19 STG 3994 9.5 14 2 1 1 1 1 1

22 J0240 CMP 22 STG 4551 10.9 18 3 1 1 1 1 1

25 J0240 CMP 25 STG 4643 12.3 18 3 1 1 1 1 1

29 J0240 CMP 29 STG 4754 13.7 18 3 1 1 1 1 1

32 J0240 CMP 32 STG 5514 15.0 22 4 1 1 1 1 1

35 J0240 CMP 35 STG 5603 16.4 22 4 1 1 1 1 1

39 J0240 CMP 39 STG 6279 17.8 26 5 1 1 1 1 1

42 J0240 CMP 42 STG 6371 19.2 26 5 1 1 1 1 1

45 J0240 CMP 45 STG 6463 20.5 26 5 1 1 1 1 1

48 J0240 CMP 48 STG 7220 21.9 30 6 1 1 1 1 1

50 (2) 25 STG 7436 24.6 30 6 1 1 1 1 1

54 (1) 29 STG + (1) 25 STG 8012 26.0 34 7 1 1 1 1 1

58 (2) 29 STG 8123 27.4 34 7 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8218 28.7 34 7 1 1 1 1 1

64 (2) 32 STG 8878 30.0 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 8967 31.4 38 8 1 1 1 1 1

70 (2) 35 STG 9056 32.8 38 8 1 1 1 1 1

74 (1) 39 STG + (1) 35 STG 9832 34.2 38 4 9 1 1 1 1 1

78 (2) 39 STG 9943 35.6 38 4 9 1 1 1 1 1

81 (1) 42 STG + (1) 39 STG 10035 37.0 38 4 9 1 1 1 1 1

84 (2) 42 STG 10592 38.4 38 8 10 1 1 1 1 1 THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-8 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 325: Wood Group ESP Catalogue

Wood Group ESP, Inc. SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ7500) J0240 Motor Group

87 (1) 45 STG + (1) 42 STG 10684 39.7 38 8 10 1 1 1 1 1

90 (2) 45 STG 10776 41.0 38 8 10 1 1 1 1 1

93 (1) 48 STG + (1) 45 STG 11433 42.4 38 12 11 1 1 1 1 1

96 (2) 48 STG 11525 43.8 38 12 11 1 1 1 1 1

99 (1) 53 STG + (2) 32 STG 12331 46.4 38 16 12 1 1 1 1 1

102 (2) 35 STG + (1) 32 STG 12420 47.8 38 16 12 1 1 1 1

105 (3) 35STG 12259 49.2 38 16 12 1 1 1 1

109 (1) 39 STG + (2) 35 STG 12935 50.6 38 20 13 1 1 1 1

113 (2) 39 STG + (1) 35 STG 13046 52.0 38 20 13 1 1 1 1

117 (3) 39STG 13157 53.4 38 20 13 1 1 1 1

120 (1) 42 STG + (2) 39 STG 13814 54.8 38 14 14 THRUST LIMIT: 60Hz = 83 stages, 50Hz = 119 stages . Consider E0220 pump. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

1 1 1 1

www.woodgroup-esp.com

Page-9

Page 326: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ9000) J0270 Motor Group

2 J0270 CMP 02 STG 3425 2.7 14 1 1 1 1 1 1

6 J0270 CMP 06 STG 3543 4.0 14 1 1 1 1 1 1

9 J0270 CMP 09 STG 3636 5.4 14 1 1 1 1 1 1

12 J0270 CMP 12 STG 3793 6.8 14 2 1 1 1 1 1

15 J0270 CMP 15 STG 3886 8.2 14 2 1 1 1 1 1

19 J0270 CMP 19 STG 3998 9.5 14 2 1 1 1 1 1

22 J0270 CMP 22 STG 4555 10.9 18 3 1 1 1 1 1

25 J0270 CMP 25 STG 4648 12.3 18 3 1 1 1 1 1

29 J0270 CMP 29 STG 4760 13.7 18 3 1 1 1 1 1

32 J0270 CMP 32 STG 5520 15.0 22 4 1 1 1 1 1

35 J0270 CMP 35 STG 5610 16.4 22 4 1 1 1 1 1

39 J0270 CMP 39 STG 6287 17.8 26 5 1 1 1 1 1

42 J0270 CMP 42 STG 6379 19.2 26 5 1 1 1 1 1

45 J0270 CMP 45 STG 6472 20.5 26 5 1 1 1 1 1

48 J0270 CMP 48 STG 7230 21.9 30 6 1 1 1 1 1

50 (2) 25 STG 7446 24.6 30 6 1 1 1 1 1

54 (1) 29 STG + (1) 25 STG 8023 26.0 34 7 1 1 1 1 1

58 (2) 29 STG 8135 27.4 34 7 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8230 28.7 34 7 1 1 1 1 1

64 (2) 32 STG 8890 30.0 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 8730 31.4 38 8 1 1 1 1 1

70 (2) 35 STG 8820 32.8 38 8 1 1 1 1 1

74 (1) 39 STG + (1) 35 STG 9597 34.2 38 4 9 1 1 1 1 1

78 (2) 39 STG 9709 35.6 38 4 9 1 1 1 1 1

81 (1) 42 STG + (1) 39 STG 9801 37.0 38 4 9 1 1 1 1 1

84 (2) 42 STG 10358 38.4 38 8 10 1 1 1 1 1

87 (1) 45 STG + (1) 42 STG 10451 39.7 38 8 10 1 1 THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-10 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 327: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with J 700 Series SP1000 Pumps.

J 700 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TJ12000) J0360 Motor Group

2 J0360 CMP 02 STG 3400 2.7 14 1 1 1 1 1 1

5 J0360 CMP 05 STG 3483 4.0 14 1 1 1 1 1 1

8 J0360 CMP 08 STG 3564 5.4 14 1 1 1 1 1 1

11 J0360 CMP 11 STG 3712 6.8 14 2 1 1 1 1 1

14 J0360 CMP 14 STG 3795 8.2 14 2 1 1 1 1 1

17 J0360 CMP 17 STG 3877 9.5 14 2 1 1 1 1 1

20 J0360 CMP 20 STG 4423 10.9 18 3 1 1 1 1 1

23 J0360 CMP 23 STG 4506 12.3 18 3 1 1 1 1 1

26 J0360 CMP 26 STG 4589 13.7 18 3 1 1 1 1 1

29 J0360 CMP 29 STG 5337 15.0 22 4 1 1 1 1 1

32 J0360 CMP 32 STG 5418 16.4 22 4 1 1 1 1 1

35 J0360 CMP 35 STG 6065 17.8 26 5 1 1 1 1 1

38 J0360 CMP 38 STG 6149 19.2 26 5 1 1 1 1 1

41 J0360 CMP 41 STG 6231 20.5 26 5 1 1 1 1 1

44 J0360 CMP 44 STG 6978 21.9 30 6 1 1 1 1 1

46 (2) 23 STG 7162 24.6 30 6 1 1 1 1 1

49 (1) 26 STG + (1) 23 STG 7710 26.0 34 7 1 1 1 1 1

52 (2) 26 STG 7793 27.4 34 7 1 1 1 1 1

55 (1) 29 STG + (1) 26 STG 7876 28.7 34 7 1 1 1 1 1

58 (2) 29 STG 8524 30.0 38 8 1 1 1 1 1

61 (1) 32 STG + (1) 29 STG 8605 31.4 38 8 1 1 1 1 1

64 (2) 32 STG 8686 32.8 38 8 1 1 1 1 1

67 (1) 35 STG + (1) 32 STG 9333 34.2 38 4 9 1 1 1 1 1

70 (2) 35 STG 9415 35.6 38 4 9 1 1 1 1 1 THRUST LIMIT: 60Hz = 60 stages, 50Hz = 86 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-11

Page 328: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.

M 950 SERIES SP1000 ESP Pump Description Pumps have SS & AR Heads & Bases

Discharge Assembly

4” Coated Steel

(TM19000) M0560 Motor Group

8 M0560 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1

9 M0560 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1

10 M0560 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1

11 M0560 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1

12 M0560 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1

13 M0560 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1

14 M0560 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1

15 M0560 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1

16 M0560 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1

17 M0560 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1

18 M0560 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1

19 M0560 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1

20 M0560 CMP A-CUT 20 STG 5464 13.6 18 3 1 1 1 1 1

21 M0560 CMP A-CUT 21 STG 6199 14.2 22 4 1 1 1 1 1

22 M0560 CMP A-CUT 22 STG 6266 14.8 22 4 1 1 1 1 1

23 M0560 CMP A-CUT 23 STG 6331 15.4 22 4 1 1 1 1 1

24 M0560 CMP A-CUT 24 STG 6398 16.0 22 4 1 1 1 1 1

25 M0560 CMP A-CUT 25 STG 6468 16.6 22 4 1 1 1 1 1

26 M0560 CMP A-CUT 26 STG 6536 17.2 22 4 1 1 1 1 1

27 M0560 CMP A-CUT 27 STG 7168 17.8 26 5 1 1 1 1 1

28 M0560 CMP A-CUT 28 STG 7232 18.4 26 5 1 1 1 1 1

29 M0560 CMP A-CUT 29 STG 7302 19.0 26 5 1 1 1 1 1

30 M0560 CMP A-CUT 30 STG 7369 19.6 26 5 1 1 1 1 1

31 M0560 CMP A-CUT 31 STG 7437 20.2 26 5 1 1 1 1 1 THRUST LIMIT: 60Hz = 21 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-12 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 329: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with M 950 Series SP1000 Pumps.

M 950 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

6” Coated Steel

(TM24000) M0700 Motor Group

8 M0700 CMP A-CUT 08 STG 4198 6.3 14 2 1 1 1 1 1

9 M0700 CMP A-CUT 09 STG 4266 6.9 14 2 1 1 1 1 1

10 M0700 CMP A-CUT 10 STG 4326 7.5 14 2 1 1 1 1 1

11 M0700 CMP A-CUT 11 STG 4393 8.1 14 2 1 1 1 1 1

12 M0700 CMP A-CUT 12 STG 4461 8.7 14 2 1 1 1 1 1

13 M0700 CMP A-CUT 13 STG 4528 9.3 14 2 1 1 1 1 1

14 M0700 CMP A-CUT 14 STG 5060 9.9 18 3 1 1 1 1 1

15 M0700 CMP A-CUT 15 STG 5127 10.6 18 3 1 1 1 1 1

16 M0700 CMP A-CUT 16 STG 5195 11.2 18 3 1 1 1 1 1

17 M0700 CMP A-CUT 17 STG 5266 11.8 18 3 1 1 1 1 1

18 M0700 CMP A-CUT 18 STG 5333 12.4 18 3 1 1 1 1 1

19 M0700 CMP A-CUT 19 STG 5396 13.0 18 3 1 1 1 1 1

20

21

22

23

24

25

26

27

28

29

30

31

M0700 CMP A-CUT 20 STG M0700 CMP A-CUT 21 STG HSS M0700 CMP A-CUT 22 STG HSS M0700 CMP A-CUT 23 STG HSS M0700 CMP A-CUT 24 STG HSS M0700 CMP A-CUT 25 STG HSS M0700 CMP A-CUT 26 STG HSS M0700 CMP A-CUT 27 STG HSS M0700 CMP A-CUT 28 STG HSS M0700 CMP A-CUT 29 STG HSS M0700 CMP A-CUT 30 STG HSS M0700 CMP A-CUT 31 STG HSS

5464 13.6 18

6199 14.2 22

6266 14.8 22

6331 15.4 22

6398 16.0 22

6468 16.6 22

6536 17.2 22

7168 17.8 26

7232 18.4 26

7302 19.0 26

7369 19.6 26

7437 20.2 26

3 1

4 1

4 1

4 1

4 1

4 1

4 1

5 1

5 1

5 1

5 1

5 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

THRUST LIMIT: 60Hz = 22 stages, 50Hz = 31 stages . Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009 Page-13

Page 330: Wood Group ESP Catalogue

Wood Group ESP, Inc.

SURFACE PUMPING SYSTEM PRE-SELECTION AND BUILD with N 950 Series SP1000 Pumps.

N 950 SERIES SP1000 ESP Pump Description

Pumps have SS & AR Heads & Bases

Discharge Assembly

6” Coated Steel

(TN35000) N1150 Motor Group

1 N1150 CMP A-CUT 1 STG 3786 2.4 14 1 1 1 1 1 1

2 N1150 CMP A-CUT 2 STG 3862 3.0 14 1 1 1 1 1 1

3 N1150 CMP A-CUT 3 STG 3938 3.6 14 1 1 1 1 1 1

4 N1150 CMP A-CUT 4 STG 4014 4.2 14 1 1 1 1 1 1

5 N1150 CMP A-CUT 5 STG 4087 4.7 14 1 1 1 1 1 1

6 N1150 CMP A-CUT 6 STG 4162 5.3 14 1 1 1 1 1 1

7 N1150 CMP A-CUT 7 STG 4303 5.9 14 2 1 1 1 1 1

8 N1150 CMP A-CUT 8 STG 4379 6.5 14 2 1 1 1 1 1

9 N1150 CMP A-CUT 9 STG 4455 7.1 14 2 1 1 1 1 1

10 N1150 CMP A-CUT 10STG 4528 7.6 14 2 1 1 1 1 1

11 N1150 CMP A-CUT 11STG 4604 8.2 14 2 1 1 1 1 1 THRUST LIMIT: 60Hz = 8 stages, 50Hz = 11 stages. Selections listed are a guide only, for confirmation contact WG ESP.

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Page-14 Product Catalog - Surface Pumping Systems - Copyright Wood Group ESP, Inc. - October, 2009

Page 331: Wood Group ESP Catalogue

Wood Group ESP, Inc.

WELLHEAD EQUIPMENT WELLHEADS HHS - COMPLETE UNIT

PART NUMBER CSG O.D.

TBG

4 1/2 5 1/2

7

8 5/8

9 5/8

10 3/4

13 3/8

EUE #1 RND #1 FLAT

2 3/8 2 7/8 2 3/8 741261 2 7/8 741263 2 3/8 2 7/8 741234 3 1/2 741241 741243 2 3/8 2 7/8 3 1/2 4 1/2 2 3/8 2 7/8 3 1/2 741259 4 1/2 741482 741260 5 1/2 741251 2 7/8 4 1/2 741255 5 1/2 741253 7 741254 6 741262 7 6 5/8 741285

#2 RND #2 FLAT #4 RND

741205 741202 741211 741208 741217 741214 741223 741220 741229 741226

741233 741237 741232 741240 741242 741239 741244 741245 721247

741248 741257

741249 741529 741250

741455

741252

741283

#4 FLAT #6 RND #6 FLAT #8 RND

741204 741201 741203 741200 741210 741207 741209 741206 741216 741213 741215 741212 741222 741219 741221 741218 741228 741225 741227 741224 741236 741231 741235 741230 741284 741238

741256 741246

741458

741798

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 1

Page 332: Wood Group ESP Catalogue

Wood Group ESP, Inc.

WELLHEAD EQUIPMENT WELLHEADS HHS - TOP PLATE

PART NUMBER CSG O.D.

TBG

4 1/2

5 1/2

7

8 5/8 9 5/8

10 3/4 13 3/8

PLATE

EUE #1 RND #1 FLAT

2 3/8 2 7/8 2 3/8 741377

2 7/8 741410

2 3/8 2 7/8 741410 3 1/2 741410 2 7/8 4 1/2 2 3/8 2 7/8 3 1/2 741434 4 1/2 741437 4 1/2 741419 6 741467 6 5/8 741467 7

#2 RND #2 FLAT #4 RND

741377 741368 741395 741386 741377 741368

741395 741386

741377 741368 741422 741395 741386

741410

741440 741444

741453

#4 FLAT #6 RND #6 FLAT #8 RND

741374 741365 741371 741362 741392 741383 741389 741380 741374 741365 741371 741362

741392 741383 741389 741380

741374 741365 741371 741362 741392 741383 741389 741380 741472

741416

741474

WELLHEADS HHS - BOTTOM PART NUMBER

CSG O.D. TBG

4 1/2 5 1/2

7 8 5/8 9 5/8 10 3/4 13 3/8

EUE #1 RND #1 FLAT

2 3/8 2 7/8 2 3/8 741375 2 7/8 741408 2 3/8 2 7/8 741423 741408 3 1/2 741405 741408 2 7/8 4 1/2 2 3/8 2 7/8 3 1/2 741448 741432 4 1/2 741435 4 1/2 741417 6 741465 6 5/8 741451 7

#2 RND #2 FLAT #4 RND

741375 741366 741393 741384 741375 741366 741393 741384 741375 741366

741420 741393 741384 741402 741408 741399

741426

741438 741442 741449

741465

#4 FLAT #6 RND #6 FLAT #8 RND

741372 741363 741369 741360 741390 741381 741387 741378 741372 741363 741369 741360 741390 741381 741387 741378 741372 741363 741369 741360 741390 741381 741387 741378 741470 741396

741414

741459

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page-2 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Page 333: Wood Group ESP Catalogue

Wood Group ESP, Inc. WELLHEAD EQUIPMENT

WELLHEADS HHS - PACKOFF RUBBERS

PART NUMBER CSG O.D.

TBG

4 1/2 5 1/2

7

8 5/8 9 5/8

10 3/4 13 3/8

GLAND

EUE #1 RND #1 FLAT

2 3/8 2 7/8 2 3/8 741359 2 7/8 741412 2 3/8 2 7/8 741424 741412 3 1/2 741266 741412 2 7/8 4 1/2 2 3/8 2 7/8 3 1/2 741433 4 1/2 741436 4 1/2 741418 7 741800 6 741466 6 5/8 741452 7

#2 RND #2 FLAT #4 RND

741376 741367 741394 741385 741376 741367 741394 741385 741376 741367

741421 741394 741385 741409

741439 741443

741466

#4 FLAT #6 RND #6 FLAT #8 RND

741373 741364 741361 741391 741382 741388 741379 741373 741364 741361 741391 741382 741388 741379 741373 741364 741361 741391 741382 741388 741379 741471

741415

741473

WELLHEAD HHS - BODY - SLIPS - PACKING

CSG O.D

BODY

4 1/2 5 1/2 7 8 5/8 9 5/8 10 3/4 13 3/8

PART

NUMBER 2 3/8 2 7/8

741350 741300 741301 741351 741300 741301 741352 741300 741301 741353 741430 741354 741304 741441 741355 741469

SLIPS PART NUMBER

3 1/2 4 1/2 5 1/2 6

741302 741429

741308 741303

741305

PACKING GLAND

6 5/8 7 PART NUMBER

741340 741340 741340 741342 741341 741341

741450 741464 741468

HHS SPECIFICATIONS

TYPE

HHS HHS HHS HHS HHS HHS HHS HHS HHS

CASING SIZE TUBING SIZE O.D. (Inches) O.D. (Inches)

4 1/2, 5 1/2, 7 2 3/8 4 1/2, 5 1/2, 7 2 7/8

7 3 1/2 8 5/8 2 3/8, 3 1/2 8 5/8 4 1/2 8 5/8 5 1/2

9 5/8, 10 3/4 2 3/8, 3 1/2 9 5/8, 10 3/4 4 1/2 9 5/8, 10 3/4 5 1/2

RECOMMENDED MAX LOAD

Lbs Kgs 80,000 36,000 80,000 36,000 80,000 36,000

100,000 45,000 100,000 45,000 100,000 45,000 100,000 45,000 100,000 45,000 100,000 45,000

MAXIMUM SETTING DEPTH WEIGHT

(Safety Factor = 2.0) Ft. M. Lbs Kgs

10,000 3,048 144 66 7,100 2,165 144 66 4,900 1,495 148 68 4,900 1,495 186 85 3,200 975 186 85 2,600 790 186 85 4,900 1,495 226 103 3,200 975 226 103 2,600 790 226 103

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 3

Page 334: Wood Group ESP Catalogue

Wood Group ESP, Inc. Bolt On Head

Couplings between Units Couplings are shipped at the top of each unit except for the coupling adapter at the bottom of the seal and the pump to intake (or GS) that must be ordered separately. All coupling splines are SAE 6 tooth, unless noted as INV (Involute).

Coupling TA/TR3 TD/TR387/TR4 TG/TR5 TE/TR5/E56 TH/TR5 TJ/TR7 TM/TR7 TN 919415

Pump

Pump Intake or Gas Separator Seal

Pump To

Pump

Pump To

Intake or GS

(3/8 )

914341 (5/8)

934182 (11/16)

Cprsn

120555 (5/8)

120556 (11/16)

919605 (3/8 to 11/16)

912022 (5/8 to 11/16)

934182 (11/16)

1008556 (1/2)

926477 (5/8)

934182 (11/16)

934026 (7/8)

Cprsn

120554 (1/2)

120555 (5/8)

120556 (11/16)

120557 (7/8)

934281 5/8”- 7/8”

934232

(11/16 to 7/8)

934026 (7/8)

934026 (7/8)

1011709 (1) 120557 (7/8)

123270

Cprsn (1)

952572

120557 (7/8) (1-3/16)

123270 (1)

949388 949388 (7/8 to (7/8 to 1-3/16) 1-3/16)

123247 949651 (1-3/16)

(1 to 1-3/16) 949651

1”- 1 3/16”

123270 (1) 952572 1032770

952572 (1-3/16) (1-1/2) (1-3/16)

952572 (1 3/16)

952572 1032770 949651 (1-3/16) (1-1/2)

(1 to 1-3/16)

Intake or GS To Seal

912071 (11/16 to 934026 (7/8)

3/4)

960765 944512 123247

(1-3/16 to (1 3/16) (1-3/16)

1-1/2) Seal

to Seal Seal

926956 Unit Adptr & Cplg (3/4) 740211 (7/8)

943829 (1-3/16) 960245

151409 (1-3/16 HL) (1-1/2)

151407 (1-3/16 pre-shimmed) Coupling Adapter

1046754 (3/4 to 1-3/16)

960641 1002575

945592 (1-3/16 to 2) (1-1/2 to (7/8 to 1-1/2)

2-1/4)

Motor

Type 62 & 92 Seal 1000124 To 1042043 (1-1/8 to 1- 1/2)

Motor (7/8 to (Sgl or UT) 1-3/16) Type 92 HTI

or BOH 120697 (1-1/8 to 1-1/2) Inv

Type 62 SGL: 947986 (2 to 1-3/16)

960294 Type 62 & 92 UT: 948042 (2-1/4 to

(2 to 1- 3/8) (1- 1/2)

Type 92HTI: 121437 (2 to 1-3/8) Inv

Type 62: 933523 (1)

Motor

Motor Base or Sensor

Motor To

Motor 914259 (CT or LT) (11/16)

Type 92: 110716 Type 62: 944165 (1-3/16) (1-1/8)

Type 92: 1017623 (1-3/8) Type 92 HTI

120696 Type 92 HTI to 92 Std: 141712 (1-1/8) Inv (1-3/8 inv to 1-3/8)

Type 62 to 92 Type 92HTI: 121784 (1-3/8) Inv 120862

(1 to 1-1/8) Type 92-62: 141710 (1-3/16 to 1-3/8)

Type 92 - 62 120787

(1-1/8 to 1)

961961 (1-1/2)

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page-4 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Page 335: Wood Group ESP Catalogue

Wood Group ESP, Inc.

MISCELLANEOUS EQUIPMENT CHECK VALVES AND BLEEDER VALVES

DESCRIPTION

CHECK VALVES -up to 2200 psi CHECK VALVE 2 3/8” - 8rd 2200 CHECK VALVE 2 3/8” - 8rd 2200 SST CHECK VALVE 2 7/8” - 8rd 2200 CHECK VALVE 2 7/8” - 8rd 2200 SST CHECK VALVE 3 1/2” - 8rd 2200 CHECK VALVE 3 1/2” - 8rd 2200 SST CHECK VALVES -up to 5000 psi CHECK VALVE 2 3/8” - 8rd 5000 CHECK VALVE 2 3/8” - 8rd 5000 SST CHECK VALVE 2 7/8” - 8rd 5000 CHECK VALVE 2 7/8” - 8rd 5000 SST CHECK VALVE 3 1/2” - 8rd 5000 CHECK VALVE 3 1/2” - 8rd 5000 SST BLEEDER VALVES BLEEDER VALVE 2 3/8” - 8rd BLEEDER VALVE 2 7/8” - 8rd BLEEDER VALVE 3 1/2” - 8rd CASING CHECK & BLEEDER VALVE 4 1/2” - 8rd CASING CHECK & BLEEDER VALVE 5 1/2” - 8rd CASING CHECK & BLEEDER VALVE 7” - 8rd

WEIGHT PART Lbs. Kgs. NUMBER

6 2.72 913939 6 2.72 120169

10 4.54 925206 10 4.54 120168 16 7.26 926386 16 7.26 143565

9 4.08 145935 9 4.08 145936

15 6.80 143316 15 6.80 143317 24 10.89 145937 24 10.89 143327

6 2.72 912501

10 4.54 925339 16 7.26 926394

127400 127402 127403

BREAK OFF PLUGS BRASS 2”, 2 3/8”, 2 7/8”, and 3 1/2” 0.30 0.14 911966 MONEL 2”, 2 3/8”, 2 7/8”, and 3 1/2” 0.30 0.14 925354

REDUCING NIPPLES 2 3/8” OD 8rd x 2 7/8” OD 8rd 2.5 1.13 917567 2 3/8” OD 8rd x 3 1/2” OD 8rd 7.5 3.40 917575 2 7/8” OD 8rd x 3 1/2” OD 8rd 7.5 3.40 917583

SHIPPING BOXES w/o Hinges EQUIPMENT DIA

INSIDE

Type 300-700 Series 7”

Type 300-900 Series 12”

LENGTH WEIGHT PART Feet Meters Lbs. Kgs NUMBER

6 1.8 146 66.2 741111 7.5 2.3 188 85.3 741121

12.5 3.8 351 159.2 741112 15.5 4.7 435 197.3 741113 18.5 5.6 500 226.8 741114 23 7.0 621 281.7 741115 26 7.9 750 340.2 741116

28.5 8.7 810 367.4 741117 32 9.8 926 420.0 741118 36 11.0 1042 472.7 741119 7.5 2.3 310 140.6 741124 12 3.7 495 224.5 741120 15 4.6 619 280.8 741127 23 7.0 949 430.5 741125 26 7.9 1073 486.7 741126 34 10.4 1403 636.4 741128

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 5

Page 336: Wood Group ESP Catalogue

Wood Group ESP, Inc. MISCELLANEOUS EQUIPMENT

MONEL HARDWARE KITS SERIES TR3 TR4 TR5 TR6 TR7 TR8 PUMP 1054519 1054519 1054691 1054766 1054774 INTAKE 1054519 1054519 1054691 1054766 1054774 GAS SEPARATOR 1054519 1054519 1054691 SEAL 1054527 1054584 1054709 1054782 1054782 MOTOR (SINGLE) 1054535 1054592 1054717 1054790 MOTOR (UT) 1054543 1054600 1054725 1054808 MOTOR (CT) 1054550 1054618 1054733 1059162 MOTOR (LT) 1054568 1054626 1054741 1054816 SENSOR- PRESS & TEMP 1054576 1054683 1054758 1054824 SENSOR - PRESSURE ONLY 1055078 1055086 1055094 1055102 BOLT-ON-BASE 1055078 1055086 1055094 1055102

Notes: 1. Monel bolts and washers are supplied as standard with all downhole equipment. Above monel hardware kits are available to replace or upgrade equipment and includes all bolts, washers, plugs and drain and fill components. These components may also be purchased as individual parts from any Wood Group ESP, Inc. facility. Contact your sales or service representative for individual part prices. 2. Monel bolts and washers are recommended for use with all components having a corrosion resistant coating. 3. Screws and lock washers are for the top end connection of the listed equipment.

4. O-rings are not provided in the kits.

MONEL HARDWARE KITS DESCRIPTION PART NUMBER FLAME SPRAY COATING APP-83 METAL FLAME SPRAY COATING - TOUCH-UP KIT 922872

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page-6 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Page 337: Wood Group ESP Catalogue

Wood Group ESP, Inc. MISCELLANEOUS EQUIPMENT

MOTOR OIL

DESCRIPTION

ROCON #2 MEDIUM - 5 GALLON CAN ROCON #3 (SYNTHETIC) - 5 GALLON CAN ROCON #220 (SYNTHETIC - HI-TEMP) - 55 GALLON CAN

WEIGHT PART Lbs. Kgs. NUMBER

25 11.3 985978 37 16.8 2643022 462 209.6 127295

OIL FILLING COMPONENTS OIL CAN COMPLETE WITH PUMP, HOSE. ETC 16 7.3 1059270 PUMP 1059288 PUMP HOSE 1059296 SWEDGELOK - FEMALE 1059304 PRESSURE GAGE 1059320 ALEMITE ADAPTER 1059338 CAN, 5 GALLON WITH SEAL 0.60 0.27 1059714 PIPE, 19” X .500 BLACK 127063 PIPE ELBOW 1/2” 127064 PIPE NIPPLE 1/2” X 1 1/2” 127065 PIPE REDUCER 127066 PIPE TEE 127067 SCREW, HEX HEAD 5/16” X 3/4” 127068 PLATE, STEEL 127069 PUMP HANDLE 127070 INSTALLATION CLAMPS TR3 MOTOR SHOULDER CLAMP 24 10.89 T111 TA PUMP SHOULDER CLAMP 24 10.89 T110 TA PUMP FRICTION CLAMP 24 10.89 T2345 TR3 SEAL FRICTION CLAMP 24 10.89 T2346 TR387 PUMP FRICTION CLAMP 24 10.89 T2166 TR4 MOTOR SHOULDER CLAMP 24 10.89 T478 TD PUMP SHOULDER CLAMP 24 10.89 T479 TD PUMP FRICTION CLAMP 24 10.89 T328 TR5 MOTOR CLAMP 24 10.89 T480 TG PUMP FRICTION CLAMP 24 10.89 T185 TH PUMP FRICTION CLAMP 24 10.89 T2344 TJ PUMP SHOULDER CLAMP 24 10.89 T504 TR7 MOTOR CLAMP 24 10.89 T772 TR7 SEAL FRICTION CLAMP 24 10.89 T2292 TM PUMP SHOULDER CLAMP 24 10.89 T484 TM PUMP FRICTION CLAMP 24 10.89 T773 TN PUMP FRICTION CLAMP 24 10.89 T2287 Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com

Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 7

Page 338: Wood Group ESP Catalogue

Wood Group ESP, Inc. MISCELLANEOUS EQUIPMENT

ADAPTER KITS

DESCRIPTION PART NUMBER TD PUMP (.875” SHAFT) TO TR5 INTAKE OR RGS 740220 TD PUMP (.687” SHAFT) TO TR5 INTAKE OR RGS 740226 TD PUMP (.625” SHAFT) TO TR5 INTAKE OR RGS 740235 TD INTAKE OR RGS TO TR5 SEAL 740218 TJ / TM / TN INTAKE TO TR5 SEAL 740225 TR7 SEAL TO TR5 MOTOR 740237 TR7 SEAL TO TR7 SEAL 740238 TR4 SEAL TO TR4 SEAL 740211 ADAPTER KITS COMPONENT PARTS TD INTAKE OR RGS TO TR5 SEAL - BODY TD INTAKE OR RGS TO TR5 SEAL - COUPLING TD PUMP (.875” SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099 TD PUMP (.875” SHAFT) TO TR5 INTAKE OR RGS - COUPLING 943803 TD PUMP (.687” SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099 TD PUMP (.687” SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000454 TD PUMP (.625” SHAFT) TO TR5 INTAKE OR RGS - BODY 1010099 TD PUMP (.625” SHAFT) TO TR5 INTAKE OR RGS - COUPLING 1000447 TD INTAKE OR RGS TO TR5 SEAL - BODY TD INTAKE OR RGS TO TR5 SEAL - COUPLING TJ / TM / TN INTAKE TO TR5 SEAL - BODY 740266 TJ / TM / TN INTAKE TO TR5 SEAL - COUPLING 9601112 TR7 SEAL TO TR5 MOTOR - BODY 132718 TR7 SEAL TO TR5 MOTOR - COUPLING TR7 SEAL TO TR7 SEAL - BODY 960641 TR7 SEAL TO TR7 SEAL - COUPLING TR4 SEAL TO TR4 SEAL - BODY 740250 TR4 SEAL TO TR4 SEAL - COUPLING 740252

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page-8 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Page 339: Wood Group ESP Catalogue

Wood Group ESP, Inc. MISCELLANEOUS EQUIPMENT

SEAL TO INTAKE ADAPTORS DESCRIPTION PART NUMBER

338 CL .750 X 338 ESP BOI OR RGS .687 734 734SS 734XX 338 CL .750 X 338 ESP BOI OR RGS .875 735 735SS 735XX 338 CL .750 X 55 ODI PUMP RPS .687 736 736SS 736XX 338 CL .750 X 55 ODI RGS .875 737 737SS 737XX 400 CL .875 X 400 ESP BOI OR RGS .875 700 700SS 700XX 400 CL .875 X 55 ODI PUMP RPS .688 701 701SS 701XX 400 CL .875 X 55 ODI PUMP RPSLA 1.00 702 702SS 702XX 400 CL .875 X 55 ODI RGS .875 703 703SS 703XX 400 CL .875 X 540 ESP BOI OR RGS 1.187 738 738SS 738XX 400 CL .875 X 70 ODI PUMP KPS .875 739 739SS 739XX 400 CL .875 X 70 ODI PUMP KPSLA 1.250 750 750SS 750XX 400 CL .875 X 70 ODI RGS 1.125 751 751SS 751XX 513 CL 1.00 X 55 ODI PUMP RPS .688 710 710SS 710XX 513 CL 1.00 X 55 ODI PUMP RPSLA 1.00 711 711SS 711XX 513 CL 1.00 X 55 ODI RGS .875 712 712SS 712XX 513 CL 1.00 X 400 ESP BOI OR RGS .875 713 713SS 713XX 513 CL 1.00 X 70 ODI PUMP KPS .875 714 714SS 714XX 513 CL 1.00 X 70 ODI PUMP KPSLA 1.250 715 715SS 715XX 513 CL 1.00 X 70 ODI RGS 1.125 716 716SS 716XX 513 CL 1.00 X 540 ESP BOI OR RGS 1.187 717 717SS 717XX

338/375 ESP .750 X 338 CL PUMP OR RGS .625 758 758SS 758XX 338/375 ESP .750 X 338 CL PUMP OR RGS .687 759 759SS 759XX 338/375 ESP .750 X 400 CL PUMP .687 760 760SS 760XX 338/375 ESP .750 X 400 CL HV PMP / RGS .875 761 761SS 761XX 338/375 ESP .750 X 55 ODI PUMP RPS .688 762 762SS 762XX 338/375 ESP .750 X 55 ODI PUMP RPSLA 1.00 763 763SS 763XX 338/375 ESP .750 X 55 ODI RGS .875 764 764SS 764XX 400 ESP .875 X 338 CL PUMP OR RGS .625 765 765SS 765XX 400 ESP .875 X 338 CL PUMP OR RGS .687 766 766SS 766XX 400 ESP .875 X 400 CL PUMP .687 704 704SS 704XX 400 ESP .875 X 55 ODI PUMP RPS .688 705 705SS 705XX 400 ESP .875 X 55 ODI PUMP RPSLA 1.00 706 706SS 706XX 400 ESP .875 X 55 ODI RGS .875 707 707SS 707XX 400 ESP .875 X 513 CL BOI OR RGS .875 768 768SS 768XX 400 ESP .875 X 70 ODI PUMP KPS .875 769 769SS 769XX 400 ESP .875 X 70 ODI PUMP KPSLA 1.25 770 770SS 770XX 400 ESP .875 X 70 ODI RGS 1.125 771 771SS 771XX 400 ESP .875 X 540 ESP BOI OR RGS 1.187 772 772SS 772XX 400 ESP .875 X 400 CL HV PUMP/RGS .875 799 799SS 799XX 540 ESP 1.187 X 400 CL PUMP .687 718 718SS 718XX 540 ESP 1.187 X 55 ODI PUMP RPS .688 719 719SS 719XX 540 ESP 1.187 X 55 ODI PUMP RPSLA 1.00 720 720SS 720XX 540 ESP 1.187 X 55 ODI RGS .875 721 721SS 721XX 540 ESP 1.187 X 513 CL BOI OR RGS .875 722 722SS 722XX 540 ESP 1.187 X 70 ODI PUMP KPS .875 723 723SS 723XX 540 ESP 1.187 X 70 ODI PUMP KPSLA 1.250 724 724SS 724XX 540 ESP 1.187 X 70 ODI RGS 1.125 725 725SS 725XX 540 ESP 1.187 X 400 ESP BOI OR RGS .875 740 740SS 740XX 540 ESP 1.187 X 400 CL HV PMP/RGS .875 773 773SS 773XX 540 ESP 1.187 X 562 CL PUMP 1.187 774 774SS 774XX

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009 Page 9

Page 340: Wood Group ESP Catalogue

Wood Group ESP, Inc. MISCELLANEOUS EQUIPMENT

SEAL TO INTAKE ADAPTORS DESCRIPTION PART NUMBER

55 ODI .875 X 338 CL PUMP OR RGS .625 785 785SS 785XX 55 ODI .875 X 338 CL PUMP OR RGS .687 786 786SS 786XX 55 ODI .875 X 400 CL HV PMP / RGS .875 787 787SS 787XX 55 ODI .875 X 513 CL BOI OR RGS .875 788 788SS 788XX 55 ODI .875 X 562 CL PUMP 1.187 789 789SS 789XX 55 ODI .875 X 400 ESP BOI OR RGS .875 708 708SS 708XX 55 ODI .875 X 400 CL PUMP .687 709 709SS 709XX 55 ODI .875 X 540 ESP BOI OR RGS 1.187 790 790SS 790XX 70 ODI KTE 1.00 X 400 CL PUMP .687 726 726SS 726XX 70 ODI KTE 1.00 X 400 ESP BOI OR RGS .875 727 727SS 727XX 70 ODI KTE 1.00 X 513 CL BOI OR RGS .875 728 728SS 728XX 70 ODI KTE 1.00 X 540 ESP BOI OR RGS 1.187 729 729SS 729XX 70 ODI KTE 1.00 X 400 CL HV PMP / RGS .875 791 791SS 791XX 70 ODI KTE 1.00 X 562 CL PUMP 1.187 792 792SS 792XX 70 ODI KETM 1.125 X 400 CL PUMP .687 730 730SS 730XX 70 ODI KETM 1.125 X 400 ESP BOI OR RGS .875 731 731SS 731XX 70 ODI KETM 1.125 X 513 CL BOI OR RGS .875 732 732SS 732XX 70 ODI KETM 1.125 X 540 ESP BOI / RGS 1.187 733 733SS 733XX 70 ODI KETM 1.125 X 400 CL HV PMP/RGS .875 795 795SS 795XX 70 ODI KETM 1.125 X 562 CL PUMP 1.187 796 796SS 796XX

MOTOR TO SEAL ADAPTORS 375 CL X 325 / 375 ESP .75 798 798SS 798XX 450 CL 1.00 X 400 ESP .875 800 800SS 800XX 450 CL 1.00 X 540 ESP 1.187 801 801SS 450 CL 1.00 X 55 ODI .875 802 802SS 450 CL 1.00 X 70 ODI 1.125 803 803SS 544 CL 1.125 X 540 ESP 1.187 804 804SS 544 CL 1.125 X 70 ODI 1.125 805 805SS 562 CL 1.250 X 540 1.187 806 806SS 806XX 562 CL 1.250 X 70 ODI 1.125 807 807SS 375 ESP X 338 CL .750 809 809SS 456 ESP 1.125 X 400 CL .875 810 810SS 456 ESP 1.125 X 513 CL 1.00 811 811SS 456 ESP 1.125 X 55 ODI .875 812 812SS 456 ESP 1.125 X 70 ODI 1.125 813 813SS 456 ESP 1.187 X 400 CL .875 814 814SS 456 ESP 1.187 X 513 CL 1.00 815 815SS 456 ESP 1.187 X 55 ODI .875 816 816SS 456 ESP 1.187 X 70 ODI 1.125 817 817SS 540 ESP 1.187 X 513 CL 1.00 818 818SS 540 ESP 1.187 X 70 ODI 1.125 819 819SS 540 ESP 1.375 X 513 CL 1.00 820 820SS 540 ESP 1.375 X 70 ODI 1.125 821 821SS 55 ODI 1.00 X 400 CL .875 822 822SS 55 ODI 1.00 X 513 CL 1.00 823 823SS 55 ODI 1.00 X 400 ESP .875 824 824SS 824XX 55 ODI 1.00 X 540 ESP 1.187 825 825SS 70 ODI 1.312 X 513 CL 1.00 826 826SS 70 ODI 1.312 X 540 ESP 1.187 827 827SS 827XX

Wood Group ESP, Inc. The ESP Specialists www.woodgroup-esp.com Page-10 Product Catalog - Wellheads / Miscellaneous Equipment - Copyright Wood Group ESP, Inc. - October, 2009

Page 341: Wood Group ESP Catalogue

Date:Company:

Well Name:Reservoir:

Field Name:Location:Analyst:

Comments

Well DataMD TVD OD Weight Grade Con- ID Drift

(ft | m) (ft | m) (in | mm) (lb/ft | kg/m) nection (in | mm) (in | mm)

Base Prod. Interval

Datum MD: ft | m Datum Temperature: °F | °C

Datum TVD: ft | m Wellhead temperature: °F | °C

Deviation SurveyMD TVD Angle MD TVD Angle

( ft | m ) ( ft | m ) ( deg ) ( ft | m ) ( ft | m ) ( deg )DLS

( °/100' | 90m )DLS

( °/100' | 90m )

PBTDTubingTubing

CasingLinerLinerOpen HoleTop Prod. Interval

Sandstone Limestone

Vissersr
Stamp
Page 342: Wood Group ESP Catalogue

Shaft HP LimitationsThese charts are intended as general guidelines only. Refer to Technical Bulletins or Application Briefs for most recent detailed information. (For more information, contact your Wood Group ESP representative.)

COMPONENT STANDARD MATERIAL

HIGH STRENGTH

ULTRA HIGH

STRENGTH MOTORS 4130 4130 HS

SEALS MONEL K-500

OR NITRONIC 50

INCONEL 718 INCONEL 718 HS

GAS SEPARATORS

NITRONIC 50 HS INCONEL 718 INCONEL 718 HS

PUMPS MONEL K-500

OR NITRONIC 50

INCONEL 718 INCONEL 718 HS

TABLE 1

SERIES SHAFT DIA MAT’L HP @

60 HZ HP @ 50 HZ

4130 STEEL 121 100 TR-3 UT

4130 HS STEEL 149 124 4130 STEEL 81 67

TR-3 CT 4130 HS STEEL 109 91

4130 STEEL 100 83 TR-3 UT HTI

4130 HS STEEL 120 100 4130 STEEL 60 50

TR-3 CT HTI 4130 HS STEEL 80 67

TR3-UT-HTI-HP 4130 HS STEEL 162 136 TR3-CT-HTI-HP

0.984”

4130 HS STEEL 122 103

E37 HSS 0.984” 4130 HS STEEL 270 225

TR-4 STD 4130 STEEL 490 408 TR-4 HSS 1.181” 4130 HS STEEL 662 550

TR-5/E56 STD 4130 STEEL 775 645 TR-5/E56 HSS

1.377” 4130 HS STEEL 1050 870

TABLE 2 – MOTORS

SERIES SHAFT DIA MATERIAL HP @

60 HZ HP @ 50 HZ

TR-3 STD NITRONIC-50 HS 125 104 TR-3 HSS

0.687” INCONEL 718 200 167

TR-387/TR-4 STD NITRONIC-50 HS 256 213 TR-387/TR-4 HSS INCONEL 718 410 342

TR-4 UHSS 0.875”

INCONEL-718 HS 522 435

TR-5 / TR-538 / TR-675 STD

NITRONIC-50 HS 637 531

TR-5 / TR-538 / TR-675 HSS

1.188” INCONEL 718 1019 849

TABLE 3 – GAS SEPARATORS

SERIES SHAFT DIA MATERIAL HP @

60 HZ HP @ 50 HZ

TA STD NITRONIC-50 HS 125 104 TA HSS

0.687” INCONEL 718 200 167

TR-387 / TD STD NITRONIC-50 HS 256 213 TD HSS INCONEL 718 410 342

TD UHSS 0.875”

INCONEL-718 HS 522 435

TE/TG/TH/TJ/TM STD NITRONIC-50 HS 637 531 TE/TG/TH/TJ/TM HSS INCONEL 718 1019 849 TE/TG/TH/TJ/TM UHSS

1.188” INCONEL-718 HS 1350 1125

TN STD 1.5” NITRONIC-50 HS 1000 833 TABLE 4 – INTAKES

SERIES SHAFT DIA MAT’L HP @

60 HZ HP @ 50 HZ

TR-3 STD MONEL / NITRONIC 160 133

TR-3 HSS 0.750”

INCONEL 718 256 213

TR-4 STD MONEL / NITRONIC 256 213

TR-4 HSS INCONEL 718 410 342

TR-4 UHSS

0.875”

INCONEL 718 HS 522 435

TR-5 STD MONEL / NITRONIC 637 531

TR-5 HSS 1.188”

INCONEL 718 1019 849

TR-5 AR MONEL / NITRONIC 637 531

TR-5 AR HSS INCONEL 718 1019 849 TR-5 AR UHSS

1.375” (Has a 1.188” spline) INCONEL 718 HS 1340 1100

TR-562 STD MONEL / NITRONIC 690 575

TR-562 HSS 1.375”

INCONEL 718 1100 917

TR-7 STD MONEL / NITRONIC 1000 833

TR-7 HSS 1.500”

INCONEL 718 1600 1333

TR-950 STD MONEL / NITRONIC 2100 1750

TR-950 HSS 2.000”

INCONEL 718 3375 2813 TABLE 5 – SEALS

SERIES SHAFT DIA MAT’L HP @

60 HZ HP @ 50 HZ

TD – STD MONEL / NITRONIC 44 37

TD – HSS 0.500”

INCONEL 718 70 58

TA/TD – STD MONEL / NITRONIC 94 78

TA/TD – HSS 0.625”

INCONEL 718 150 125

TA/TD - STD MONEL / NITRONIC 125 104

TA/TD – HSS INCONEL 718 200 167

TA/TD – UHSS

0.687”

INCONEL 718 HS 255 212

TD/TG/TE - STD MONEL / NITRONIC 256 213

TD/TG/TE - HSS INCONEL 718 410 342

TD/TG/TE - UHSS

0.875”

INCONEL 718 HS 522 435

TG/TE/TH- STD MONEL K500 375 312 TG/TE/TH - HSS INCONEL 718 600 500

TG/TE/TH - UHSS 1.000”

INCONEL 718 HS 765 638

TE/TH/TJ/TM STD MONEL / NITRONIC 637 531

TE/TH/TJ/TM HSS INCONEL 718 1019 849 TE/TH/TJ/TM UHSS

1.188”

INCONEL 718 HS 1300 1083

TM STD MONEL / NITRONIC 760 633

TM HSS INCONEL 718 1216 1013

TM UHSS

1.375”

INCONEL 718 HS 1550 1290

TN STD MONEL / NITRONIC 1000 833

TN HSS INCONEL 718 1600 1333 TN UHSS

1.500”

INCONEL 718 HS 2040 1700 TABLE 6 – PUMPS

Vissersr
Stamp
Page 343: Wood Group ESP Catalogue

ENGINEERING TABLES

Pumps 50 Hz 2917 RPM

Const. Stage

Housing Pressure

Limit PSI Model Series O.D.

MM

Flt. Cprsn. Pancake Mixed Flow

Recommended Operating

Range M3/Day

Maximum Downthrust Per Stage

Cprsn. Pump Lbs.

BHP per

Stage

S/O Head Per

Stage Meters Std. Hi.

Pr. TA-400 X X X 40-72 15.1 0.07 5.0 TA-550 X X X 53-93 15.7 0.08 4.8 TA-900 X X X 87-140 15.8 0.10 4.6 TA-1200 X X X 120-200 15.5 0.12 4.4 TA-1500 X X X 132-265 16.0 0.18 4.0 TA-2200

338 85.85

X X 166-364 0.19 4.2

6000 6000

TD-150 X X X 11-37 17.0 0.05 5.0 TD-300 X X X 26-60 18.4 0.06 5.1 TD-460 X X X 40-79 22.2 0.08 5.9 TD-650 X X X 60-106 20.2 0.13 7.0 TD-850 X X X 73-135 21.0 0.18 6.9 TD-1250 X X X 106-199 30.1 0.30 7.4 TD-1750 X X X 159-278 11.0 0.22 6.2 TD-2200 X X X 185-371 12.4 0.36 7.0 TD-3000 X X X 265-490 11.9 0.37 5.9 TD-4300 X X X 397-689 15.6 0.58 5.9 TD-6000

400 101.60

X X X 464-994 18.8 0.82 6.2

5000 6000

TG-4000 513 130.30 X X X 424-636 29.5 0.90 11.4 5000 6000

TE-1500 X X X 106-298 34.7 0.79 15.2 TE-2700 X X X 199-437 36.8 0.90 14.8 TE-3300 X X X 291-596 41.4 1.59 15.9 TE-4200 X X X 344-649 64.6 1.78 14.4 TE-5500 X X X 464-967 35.4 1.63 13.1 TE-7000 X X X 530-1285 25.7 1.99 13.5 TE-7200 X X X 530-1285 25.7 1.99 13.3 TE-11000

538 135.65

X X 1060-1855 49.3 2.55 10.6

6000 6000

TH-15000 X X 1325-2517 49.3 5.27 14.8 TH-20000

562 142.75 X X 1987-3113 70.1 6.77 15.5

3000 3600

TJ-7500 X X 662-1457 59.0 3.41 17.0 TJ-9000 X X 662-1722 81.9 5.09 24.8 TJ-12000 X X 994-2385 100.0 6.60 22.0 TJ-20000

675 171.45

X X 1590-3445 132.0 7.31 21.4

3000 3600

A X X 1855-3180 232.6 11.28 31.1 B X X 1722-3047 194.7 8.33 26.0

TM 19000

C X X 1656-2981 158.3 7.24 21.2 TM 24000 A X X 1855-4239 229.2 17.36 31.3

B X X 2650-3842 193.5 16.38 26.5 C X X 2583-3776 154.9 11.92 21.2 TM25000

862 218.95

X X 1855-4504 253.5 20.41 35.1

2000 2400

A X X 4107-5962 642.4 34.08 45.5 B X X 3710-5697 534.8 25.52 37.9

TN 35000

C 950 241.30

X X 3378-5167 448.1 19.82 31.8 2300 2760

Vissersr
Stamp
Page 344: Wood Group ESP Catalogue

ENGINEERING TABLES Pumps 50 Hz 2917 RPM

Maximum Number of Stages Using Shaft

Thrust Brg. Load Capacity

Lbs. Thrust Brg.

(Ref Seal Section) BHP Limit Floater Pump Cprsn. Pump

Shaft Housing Model

Dia. MM

Area MM2 Std. HS

Std. @230F (Max.) #

Hi-Ld @250F (Max.) #

Std. @230F (Max.) #

Hi-Ld @250F (Max.) #

Hi-Ld @250F (Max.) #

Std. #

HS #

Std. #

Hi Pr #

TR 3 Seal Section TA-400 413 1181 165 1231 1969 870 870 TA-550 414 1184 159 967 1547 872 872 TA-900 435 1243 159 796 1274 916 916 TA-1200

15.875 197.93 78 125

461 1316 161 645 1031 969 969 TA-1500 413 1179 157 581 929 1050 1050 TA-2200

17.463 239.50 104 167

875

2500

391 1118 545 873 998 998 TR 4 Seal Section

TD-150 12.700 126.68 37 58 715 3965 323 782 1244 708 849 TD-300 448 2485 299 1231 1969 693 832 TD-460 326 1807 248 752 1203 504 605 TD-650 324 1796 272 589 942 501 601 TD-850

15.875 197.93 78 125

329 1824 262 437 699 509 610 TD-1250 254 1408 183 353 565 475 570 TD-1750 303 1682 501 474 758 568 681 TD-2200

17.463 239.50 104 167 269 1489 442 286 457 502 603

TD-3000 196 1087 460 576 922 594 713 TD-4300 197 1091 352 365 584 596 715 TD-6000

22.225

387.95

213

341

992 5500

188 1042 293 261 418 570 684 TR 5 Seal Section TG-4000 25.400 506.71 313 500 2008 10200 157 800 346 346 554 308 370

TE-1500 154 784 294 269 431 277 277 TE-2700 159 806 277 236 378 285 285 TE-3300

22.225 387.95 213 341 148 752 246 134 214 266 266

TE-4200 125 635 158 175 281 294 294 TE-5500 137 697 288 191 306 322 322 TE-7000 133 677 397 157 251 313 313 TE-7200

25.400 506.71 313 500

135 687 397 157 251 317 317 TE-11000 30.163 715.14 531 849

2008 10200

207 208 333 399 399

TH-15000 207 101 161 143 171 TH-20000

30.163 715.14 531 849 2008 10200 145 78 125 137 164

TR562 Seal Section TJ-7500 296 155 249 124 149 TJ-9000 214 104 167 85 102 TJ-12000 175 80 129 96 115 TJ-20000

30.163 715.14 531 849 17500

133 73 116 99 119

A 75 47 75 45 54 B 90 64 102 54 65

TM 19000

C 111 73 117 67 80 A 76 31 49 44 53 B 90 32 52 53 64

TM 24000

C

30.163 715.14 531 849

113 45 71 67 80 TM25000 34.925 958.00 633 1013

17500

69 31 50 40 48 A 27 24 39 36 43 B 33 33 52 43 51

TN 35000

C

38.100

1140.09

833

1333

17500

39 42 67 51 61

Vissersr
Stamp
Page 345: Wood Group ESP Catalogue

ENGINEERING TABLES Pumps 60 Hz 3500 RPM

Const. Stage

Housing Pressure

Limit PSI Model Series O.D.

Inches

Flt. Cprsn. Pancake Mixed Flow

Recommended Operating

Range - BPD

Maximum Downthrust Per Stage

Cprsn. Pump Lbs.

BHP per

Stage

S/O Head Per

Stage Ft. Std. Hi.

Pr. TA-400 338 3.38 X X X 300-540 21.8 0.12 23.5 6000 6000 TA-550 X X X 400-700 22.6 0.14 22.9 TA-900 X X X 660-1060 22.7 0.17 21.8 TA-1200 X X X 900-1500 22.3 0.21 20.6 TA-1500 X X X 1000-2000 23.0 0.31 19 TA-2200 X X 1250-2750 0.33 20 TD-150 X X X 80-280 24.5 0.081 23.5 TD-300 X X X 200-450 26.5 0.11 24.0 TD-460 X X X 300-600 32.0 0.18 33 TD-650 X X X 450-800 29.1 0.23 33.2 TD-850 X X X 550-1020 30.2 0.31 32.7 TD-1250 X X X 800-1500 43.3 0.51 35.0 TD-1750 X X X 1200-2100 15.8 0.38 29.3 TD-2200 X X X 1400-2800 17.9 0.63 33.1 TD-3000 X X X 2000-3700 17.2 0.64 28.0 TD-4300 X X X 3000-5200 22.5 1.01 27.9 TD-6000

400 4.00

X X X 3500-7500 27.0 1.41 29.2

5000 6000

TG-4000 513 513 X X X 3200-4800 42.5 1.56 54.0 5000 6000 TE-1500 X X X 800-2250 50.0 1.37 72.0 TE-2700 X X X 1500-3300 53.0 1.56 70.0 TE-3300 X X X 2200-4500 59.7 2.75 75.0 TE-4200 X X X 2600-5400 93 3.08 68.0 TE-5500 X X X 3500-7300 51.0 2.82 62.0 TE-7000 X X X 4000-9700 37.0 3.44 63.8 TE-7200 X X X 4000-9550 37.0 3.44 62.9 TE-11000

538 5.38

X X 8000-14000 71.0 4.41 50.0

6000 6000

TH-15000 X X 10000-19000 71.0 9.10 70.0 TH-20000

562 5.62 X X 15000-23500 101.0 11.70 73.0

3000 3600

TJ-7500 X X 5000-11000 85.0 5.90 80.5 TJ-9000 X X 5000-13000 118.0 8.80 117.0 TJ-12000 X X 7500-18000 144.0 11.40 104.0 TJ-16000 X X 12000-18000 145.0 12.25 93.5 TJ-20000

675 6.75

X X 12000-26000 190.0 12.63 101.0

3000 3600

A X X 14000-24000 335.0 19.50 147.0 B X X 13000-23000 280.3 14.40 123.0

TM 19000

C X X 12500-22500 227.9 12.51 100.0 A X X 14000-32000 330.0 30.0 150.2 B X X 20000-29000 278.7 28.30 125.0

TM 24000

C X X 19500-28500 223.0 20.60 100.0 TM25000

862 8.62

X X 14000-34000 365.0 35.26 166.0

2000 2400

A X X 31000-45000 925.0 58.89 215.0 B X X 28000-43000 770.1 44.10 179.0

TN 35000

C 950 9.50

X X 25500-39000 645.3 34.25 150.0 2300 2760

Vissersr
Stamp
Page 346: Wood Group ESP Catalogue

ENGINEERING TABLES Pumps 60 Hz 3500 RPM

Maximum Number of Stages Using

Shaft Thrust Brg.

Load Capacity Lbs. Thrust Brg.

(Ref Seal Section)

BHP Limit Floater Pump Cprsn. Pump

Shaft Housing Model

Dia. In.

Area In.2 Std. HS

Std. @230F (Max.)

#

Hi-Ld @250F (Max.) #

Std. @230F

(Max.) #

Hi-Ld @250F

(Max.) #

Hi-Ld @250F (Max.) #

Std. #

HS #

Std. #

Hi Pr #

TR 3 Seal Section TA-400 320 881 126 783 1253 590 590 TA-550 329 904 122 671 1074 605 605 TA-900 345 950 121 553 885 636 636 TA-1200

0.625 0.3068 94 150

366 1005 123 448 716 673 673 TA-1500 328 901 120 403 645 729 729 TA-2200

0.688 0.3712 125 200

1000 2750

311 854 379 606 693 693 TR 4 Seal Section

TD-150 0.500 0.1963 44 70 596 3004 245 543 864 491 590 TD-300 373 1882 226 855 1367 481 578 TD-460 272 1369 188 522 836 350 420 TD-650 270 1361 206 409 654 348 417 TD-850

0.625 0.3068 94 150

274 1382 199 303 485 353 424 TD-1250 212 1067 139 245 392 330 396 TD-1750 253 1274 380 329 526 394 473 TD-2200

0.688 0.3712 125 200 224 1128 335 198 317 349 419

TD-3000 163 823 349 400 640 413 495 TD-4300 164 826 267 253 406 414 497 TD-6000

0.875

0.6013

256

410

1190 6000

157 789 222 182 290 396 475 TR 5 Seal Section TG-4000 1.000 0.7854 375 600 2410 11000 131 599 259 240 385 214 257

TE-1500 129 587 220 187 299 193 193 TE-2700 132 604 208 164 263 198 198 TE-3300

0.875 0.6013 256 410 123 563 184 93 149 185 185

TE-4200 104 476 118 122 195 204 204 TE-5500 114 522 216 133 213 224 224 TE-7000 111 507 297 109 174 217 217 TE-7200

1.000 0.7854 375 600

113 514 297 109 174 220 220 TE-11000 1.188 1.1085 637 1019

2410 11000

155 144 231 277 277

TH-15000 155 70 112 99 119 TH-20000

1.188 1.1085 637 1019 109 54 87 95 114

TR562 Seal Section TJ-7500 226 108 173 86 103 TJ-9000 163 72 116 59 71 TJ-12000 134 56 89 67 80 TJ-20000

1.188 1.1085 637 1019 19250

101 50 81 69 82 A 1.188 1.1085 637 1019 57 33 52 31 38 B 69 44 71 38 45

TM 19000

C 84 51 81 46 55 A 58 21 34 31 37 B 69 23 36 37 44

TM 24000

C 86 31 49 46 55 TM25000 1.375 1.4849 760 1216

19250

53 22 34 28 33 A 21 17 27 25 30 B 25 23 36 30 36

TN 35000

C 1.500 1.7671 1000 1600 19250

30 29 47 35 43

Vissersr
Stamp
Page 347: Wood Group ESP Catalogue

ENGINEERING TABLES Model STD Motors

300 Series Motors (3.75” O.D.) 400 Series Motors (4.56” O.D.) 500 Series Motors (5.44” O.D.) H.P. Volts H.P. Volts H.P. Volts

60 Hz

50 Hz

60 Hz

50 Hz

Amps

60 Hz

50 Hz 60 Hz 50

Hz Amps

60 Hz

50 Hz

60 Hz

50 Hz

Amps

7.5 6.3 410 342 14 10 8.3 435 363 15 290 241 45 10.5 8.8 390 325 20.5 435 363 23 440 367 29

315 263 35.5 15 12.5

610 508 16 755 629 17 400 333 28 450 375 28.5

20 16.7

1020 850 12 15 12.5 900 750 14

20 16.7 750 625 17 435 363 45

18 15 265 220 51 410 342 39 710 592 28 387 323 38 690 575 22

30 25 1215 1013 16

19.5 16.3 630 525 23

25 20.8 810 675 20 435 363 60

330 275 51.5 425 354 44.5 730 608 36 440 367 38.5

30 25 750 625 25.5 880 733 30 22.5 18.8

730 608 23 400 333 55

40 33.3

1325 1104 20 370 308 51 675 563 33 450 375 72 500 417 37

35 29.2 750 625 28 725 604 45 25.5 21.3

630 525 30 420 350 62 905 754 34 770 642 33 1270 1058 25 880 733 29

50 41.7

1375 1146 22

40 33.3

1295 1079 20 425 354 91

675 563 47 645 538 59 815 679 39 870 725 45

955 796 33 970 808 39

1070 892 31 1085 904 35

50 41.7

1210 1008 27

60 50

1320 1100 30

640 533 59 755 629 60 810 675 47 1015 846 45

970 808 39

70 58.3 1265 1054 35

1330 1108 29 865 721 60

60 50

1945 1620 20 1160 967 45 540 450 82.5

80 66.6 2180 1817 23

750 625 60 705 588 90 945 788 47 835 696 76 1135 946 39 1070 892 60 1310 1092 35 1255 1046 50

70 58.3

1885 1570 24 1450 1208 45 635 529 80

100 83.3

2170 1808 29 860 717 60 855 713 88 1085 904 46 1030 858 73 1310 1092 39 1295 1079 59

80 66.7

2155 1796 24 1450 1208 45 90 75 710 592 81

120 100

2165 1804 33 960 800 59 925 771 88 Model E56 Motors 1135 946 50

130 108.3 1125 938 67

H.P. Volts 1220 1017 46 985 821 90 1460 1216 39 1210 1008 67 60

Hz 50 Hz

60 Hz

50 Hz

Amps 1930 1608 31

140 116.7 2015 1679 44

200 166.7 1403 1169 86 100 83.3 775 646 84 1075 896 87 250 208.3 1754 1462 86 1075 896 59 1240 1033 76

2055 1712 73 1355 1129 46 150 125

2105 1754 44 2355 1962 64 2205 1838 28.5 825 688 122 3858 3215 40

1190 992 60

1115 929 88.5

300 250 1744 1453 104 1487 1239 48 1423 1186 71 2105 1754 86

110 91.7 2380 1983 30 2003 1669 50

350 291.7 2034 1695 104 930 775 84

160 133.3

2185 1821 46 2455 2046 86 1040 867 76 945 788 120 3718 3098 58 1125 938 70 1275 1063 89

400 333.3 1847 1539 135 1295 1079 59 1945 1621 59 2325 1937 104 1625 1354 46

180 150

2260 1883 50 2806 2338 86

120 100

2245 1871 35 1100 917 115 2616 2180 104 1415 1179 89

450 375 1960 1633 140 200 166.7

2140 1783 54 2350 1958 116 1135 946 127 3698 3081 75

225 187.5 2235 1863 64

Vissersr
Stamp
Page 348: Wood Group ESP Catalogue

ENGINEERING TABLES Model THD Motors

300 Series Motors (3.75” O.D.) 400 Series Motors (4.56” O.D.) 500 Series Motors (5.44” O.D.) H.P. Volts H.P. Volts H.P. Volts

60 Hz

50 Hz

60 Hz

50 Hz

Amps

60 Hz

50 Hz

60 Hz

50 Hz

Amps

60 Hz

50 Hz

60 Hz

50 Hz

Amps

10 8.3 455 379 17 15 12.5 505 421 20 30 25 515 429 37 15 12.5 445 371 26 20 16.5 480 400 28 880 733 22 25 20.8 385 320 49 675 563 20 1190 992 15 490 408 39 30 25 525 437 38 45 37.5 505 421 58 1100 917 19 870 725 23 830 691 36

30 25 455 379 50 35 29.5 465 387 49 1415 1179 21 745 621 30 780 650 28 60 50 505 421 77

35 29.2 390 325 68 915 763 25 850 708 46 520 433 51 45 37.5 495 413 59 1025 854 39 865 721 30 870 725 34 1545 1288 26

40 33.3 440 367 68 50 41.5 455 379 71 75 62.5 525 437 93 595 496 49 770 642 42 845 704 58 750 625 40 855 710 36 1055 879 44 60 50 490 408 83 1480 1233 32

895 746 44 1605 1338 28 1025 854 39 90 75 750 625 76

1505 1254 27 1015 846 58

75 62.5 785 654 63 1130 942 50 945 787 52 1265 1041 45

1110 925 44 1540 1283 39

1245 1037 41 105 87.5 880 733 77 1405 1171 36 1185 988 58

90 75 745 620 79 1475 1229 45 940 783 63 120 100 1010 841 77

1130 941 52 1355 1129 58

1545 1288 39 2545 2121 30 2260 1883 27 150 125 975 812 98

105 87.5 630 525 110 1250 1041 77 870 725 80 1465 1221 65 1100 917 63 1690 1408 58 1320 1100 52 2530 2108 37 1525 1271 47 180 150 1200 1000 94 120 100 740 616 107 1510 1258 76 1000 833 80 2030 1691 58 1260 1050 61 2525 2104 43 1525 1271 52 195 162.5 1310 1092 87 2505 2088 32 210 175 1150 958 116 135 112.5 825 687 108 1410 1175 87 1115 929 79 2350 1958 57

1320 1100 67 225 187.5 1255 1046 112 1420 1183 61 1445 1204 98 1695 1413 52 2455 2046 57

2245 1871 41 240 200 1300 1083 114 150 125 900 750 112 1660 1383 92 1250 1041 79 2335 1946 65 1575 1313 61 2550 2125 59 2565 2138 38 270 225 1485 1238 115 165 137.5 1385 1154 80 2270 1892 76 1728 1440 64 2635 2196 65 2765 2304 40 300 250 1285 1071 149 180 150 1080 900 112 1510 1258 127 1210 1008 101 1650 1375 115

1310 1091 93

2495 2079 70 1505 1254 79 2610 2175 47

Vissersr
Stamp
Page 349: Wood Group ESP Catalogue
Vissersr
Stamp
Page 350: Wood Group ESP Catalogue
Vissersr
Stamp
Page 351: Wood Group ESP Catalogue
Vissersr
Stamp
Page 352: Wood Group ESP Catalogue

Copyright Wood Group ESP March 2009

ENGINEERING TABLES

API Tubular Goods SIZE

INCHES (MM) DIAMETER

INCHES / MM NOMINAL OD

THREAD

WEIGHT LB / FT OD ID DRIFT

COUPLING OD INCHES / MM

API LINE PIPE: 1-¼ (31.8) 11-1/2 V 2.30 1.660 / 42.2 1.380 / 35.1 2.054 / 52.2 1-½ (38.1) 11 to 11-1/2V 2.75 1.900 / 48.3 1.610 / 40.1 2.200 / 55.9

2 (50.8) 2-3/8 (60.3) 11-1/2 V 3.75 2.375 / 60.3 2.067 / 52.5 2.875 / 73.0 3 (76.2) 3-1/2 (88.9) 8 V 7.70 3.500 / 88.9 3.068 / 77.9 4.000 / 101.6 4 (101.6) 4-½ (114.3) 8 V 11.00 4.500 / 114.3 4.026 / 102.3 5.200 / 132.1 6 (152.4) 6-5/8 (168.4) 8 V 19.45 6.625 / 168.3 6.065 / 167.8 7.390 / 187.7 8 (203.2) 8-5/8 (219.2) 8 V 25.55 8.625 / 219.1 8.071 / 205.0 9.625 / 244.5

API TUBING (NON UPSET): 1-½ (38.1) 10 RD 2.75 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.200 / 55.8

2 (50.8) 2-3/8 (60.3) 10 RD 4.00 2.375 / 60.3 2.041 / 51.8 1.947 / 49.5 2.875 / 73.03 2-½ (63.5) 2-7/8 (73.0) 10 RD 6.40 2.875 / 73.0 2.441 / 62.0 2.347 / 59.6 3.500 / 88.9

3 (76.2) 3-½ (88.9) 10 RD 7.70 3.500 / 88.9 3.068 / 77.9 2.943 / 74.8 4.250 / 108.0 3-½ (88.9) 4 (101.6) 8 RD 9.50 4.000 / 101.6 3.548 / 90.1 3.423 / 87.0 4.750 / 120.7

API TUBING (EXTERNAL UPSET): 1-½ (38.1) 10 RD 2.90 1.900 / 48.3 1.610 / 40.9 1.516 / 38.5 2.500 / 63.5

2 (50.8) 2-3/8 (60.3) 8 RD 4.70 2.375 / 60.3 1.995 / 50.7 1.901 / 48.3 3.063 / 77.8 2-½ (63.5) 2-7/8 (73.0) 8 RD 6.50 2.875 / 73.0 2.441 / 62.0 2.347 / 59.61 3.668 / 93.2

3 (76.2) 3-½ (88.9) 8 RD 9.30 3.500 / 88.9 2.992 / 76.0 2.867 / 72.8 4.500 / 114.3 3-½ (88.9) 4 (101.6) 8 RD 11.00 4.000 / 101.6 3.476 / 88.3 3.351 / 85.1 5.000 / 127.0

4 (101.6) 4-½ (114.3) 8 RD 12.75 4.500 / 114.3 3.958 / 100.5 3.833 / 97.4 5.563 / 141.3 API TUBING REGULAR CASING:

8 RD 9.50 4.090 / 103.9 3.965 / 100.7 8 RD 11.60 4.000 / 101.6 3.875 / 98.43

4-½ (114.3)

8 RD 13.50 4.500 / 114.3

3.920 / 99.56 3.795 / 96.39 5.000 / 127.0

8 RD 14.00 5.012 / 127.3 4.887 / 124.1 8 RD 17.00 4.892 / 124.3 4.767 / 121.1 8 RD 20.00 4.778 / 121.4 4.653 / 118.2

5-½ (139.7) 8 RD 23.00

5.500 / 139.7

4.670 / 118.61 4.545 / 115.44

6.050 / 153.7

8 RD 17.00 6.135 / 155.8 6.010 / 152.7 8 RD 24.00 5.921 / 150.4 5.796 / 147.2 8 RD 28.00 5.791 / 147.09 5.666 / 143.91

6-5/8 (168.4) 8 RD 32.00

6.625 / 168.4 5.675 / 144.14 5.550 /140.97

7.390 / 187.7

8 RD 20.00 6.456 / 164.0 6.331 / 160.8 8 RD 23.00 6.366 / 161.7 6.241 / 158.5 8 RD 26.00 6.276 / 159.4 6.151 / 156.2 8 RD 29.00 6.184 / 157.07 6.059 / 153.89

7 (177.8)

8 RD 32.00

7.000 / 177.8

6.094 / 154.78 5.959 / 151.35

7.656 / 194.5

8 RD 28.00 8.017 / 203.6 7.892 / 200.5 8 RD 32.00 7.921 / 201.19 7.796 / 198.0 8 RD 36.00 7.825 / 198.8 7.700 / 195.6

8-5/8 (219.1) 8 RD 40.00

8.625 / 219.1 7.725 / 196.21 7.600 / 193.04

9.625 / 244.5

8 RD 36.00 8.921 / 226.6 8.765 /222.6 8 RD 40.00 8.835 / 224.4 8.679 / 220.5 8 RD 47.00 8.681 / 220.49 8.525 / 216.53

9-5/8 (244.5) 8 RD 53.50

9.625 / 244.5 8.535 / 216.78 8.379 / 212.82

10.625/ 269.9

8 RD 40.50 10.050 / 255.3 9.894 / 251.3 10-3/4 (273.1) 8 RD 55.50 10.750/ 273.1 9.760 / 247.9 9.604 / 243.9 11.750/ 298.5

8 RD 48.00 12.715/ 323.0 12.559/ 319.0 13-3/8 (339.9) 8 RD 68.00 13.375/ 339.9 12.415/ 315.3 12.259/ 311.4 14.375/ 365.1

Vissersr
Stamp
Page 353: Wood Group ESP Catalogue

Intentionally left Blank

Vissersr
Stamp
Page 354: Wood Group ESP Catalogue

ENGINEERING TABLES Gravity Correction Table

Weight (Density) Fluid Head Gallon Cubic

Foot Barrel Pressure per Foot Height per Pound

Buoyancy Factor

Degrees

API

Specific Gravity

Pounds Lbs / Sq In Feet Totally Immersed 60.0 0.739 6.16 46.1 259.0 0.320 3.13 0.906 59.0 0.743 6.20 46.4 260.0 0.322 3.11 0.905 58.0 0.747 6.23 46.6 262.0 0.324 3.09 0.905 57.0 0.751 6.26 46.8 263.0 0.325 3.08 0.904 56.0 0.755 6.30 47.1 265.0 0.327 3.06 0.904

55.0 0.759 6.33 47.4 266.0 0.329 3.04 0.903 54.0 0.763 6.36 47.6 267.0 0.330 3.03 0.903 53.0 0.767 6.40 47.9 269.0 0.332 3.01 0.902 52.0 0.771 6.43 48.1 270.0 0.334 2.99 0.902 51.0 0.775 6.46 48.3 271.0 0.336 2.98 0.901

50.0 0.780 6.51 48.7 273.0 0.338 2.96 0.901 49.0 0.784 6.54 48.9 275.0 0.340 2.94 0.900 48.0 0.788 6.57 49.2 276.0 0.341 2.93 0.900 47.0 0.793 6.61 49.5 278.0 0.343 2.92 0.899 46.0 0.797 6.65 49.8 279.0 0.345 2.90 0.898

45.0 0.802 6.69 50.0 281.0 0.348 2.87 0.898 44.0 0.806 6.72 50.3 282.0 0.349 2.87 0.897 43.0 0.811 6.76 50.6 284.0 0.351 2.85 0.897 42.0 0.816 6.81 50.9 286.0 03354 2.82 0.896 41.0 0.820 6.84 51.2 287.0 0.355 2.82 0.896

40.0 0.825 6.88 51.5 289.0 0.357 2.80 0.895 39.0 0.830 6.92 51.8 291.0 0.359 2.79 0.894 38.0 0.835 6.96 52.1 292.0 0.362 2.76 0.894 37.0 0.840 7.01 52.4 294.0 0.364 2.75 0.893 36.0 0.845 7.05 52.7 296.0 0.366 2.73 0.892

35.0 0.850 7.09 53.0 298.0 0.368 2.72 0.892 34.0 0.855 7.13 53.3 299.0 0.370 2.70 0.891 33.0 0.860 7.17 53.6 301.0 0.372 2.69 0.891 32.0 0.865 7.21 53.9 303.0 0.375 2.67 0.890 31.0 0.871 7.26 54.3 305.0 0.377 2.65 0.889

30.0 0.876 7.31 54.7 307.0 0.380 2.63 0.889 29.0 0.882 7.36 55.1 309.0 0.382 2.62 0.887 28.0 0.877 7.40 55.4 311.0 0.384 2.60 0.887 27.0 0.893 7.45 55.7 313.0 0.387 2.58 0.886 26.0 0.898 7.49 56.0 315.0 0.389 2.57 0.885

25.0 0.904 7.54 56.4 317.0 0.392 2.55 0.885 24.0 0.910 7.59 56.8 319.0 0.394 2.54 0.884 23.0 0.916 7.64 57.2 321.0 0.397 2.52 0.883 22.0 0.922 7.69 57.5 323.0 0.399 2.51 0.883 21.0 0.928 7.74 57.9 325.0 0.402 2.49 0.882

Vissersr
Stamp
Page 355: Wood Group ESP Catalogue

ENGINEERING TABLES

Gravity Correction Table (continued) Weight (Density) Fluid Head

Gallon Cubic Foot Barrel Pressure per Foot Height per Pound

Buoyancy Factor

Degrees

API

Specific Gravity

Pounds Lbs / Sq In Feet Totally Immersed 20.0 0.934 7.79 58.3 327.0 0.405 2.47 0.881 19.0 0.940 7.78 58.7 329.0 0.407 2.46 0.880 18.0 0.946 7.89 59.0 331.0 0.410 2.44 0.879 17.0 0.953 7.95 59.5 334.0 0.413 2.42 0.879 16.0 0.959 8.00 59.8 336.0 0.416 2.40 0.878

15.0 0.966 8.06 60.3 339.0 0.419 2.39 0.877 14.0 0.973 8.11 60.7 342.0 0.421 2.38 0.876 13.0 0.979 8.16 61.0 343.0 0.424 2.36 0.876 12.0 0.986 8.22 61.5 345.0 0.427 2.34 0.874 11.0 0.993 8.28 61.9 348.0 0.430 2.33 0.874

1.00 8.34 62.4 350.0 0.433 2.31 0.873 1.01 8.40 62.8 353.0 0.436 2.29 0.872 1.03 8.60 64.3 361.0 0.447 2.24 0.869 1.06 8.80 65.8 370.0 0.457 2.19 0.866

10.0 Degrees API or Pure

Water 1.08 9.00 67.3 378.0 0.468 2.14 0.862

1.10 9.20 68.8 386.0 0.478 2.09 0.860 1.13 9.40 70.3 395.0 0.488 2.05 0.856 1.15 9.60 71.8 403.0 0.499 2.00 0.853 1.154 9.625 72.0 404.0 0.500 2.00 0.853 1.18 9.80 73.3 412.0 0.509 1.96 0.850

1.20 10.0 74.8 420.0 0.519 1.93 0.847 1.22 10.2 76.3 428.0 0.530 1.89 0.844 1.25 10.4 77.8 437.0 0.540 1.85 0.841 1.27 10.6 79.3 445.0 0.551 1.81 0.838 1.29 10.8 80.8 454.0 0.561 1.78 0.835

1.32 11.0 82.3 462.0 0.571 1.75 0.832 1.34 11.2 83.8 470.0 0.582 1.72 0.829 1.37 11.4 85.3 479.0 0.592 1.69 0.826 1.39 11.6 86.8 487.0 0.603 1.66 0.823 1.41 11.8 88.3 496.0 0.613 1.63 0.820

1.44 12.0 89.8 504.0 0.623 1.61 0.817 1.46 12.2 91.3 512.0 0.634 1.58 0.814 1.49 12.4 92.8 521.0 0.644 1.55 0.810 1.51 12.6 94.3 529.0 0.655 1.53 0.808 1.53 12.8 95.8 538.0 0.665 1.50 0.804

1.56 13.0 97.2 546.0 0.675 1.48 0.801 1.58 13.2 98.7 554.0 0.686 1.46 0.798 1.61 13.4 100.0 563.0 0.696 1.44 0.795 1.63 13.6 102.0 571.0 0.706 1.42 0.792

Salt Water

1.65 13.8 103.0 580.0 0.717 1.39 0.789

Vissersr
Stamp
Page 356: Wood Group ESP Catalogue

Copyright Wood Group ESP January 2000

ENGINEERING TABLES Electrical Terms and Definitions

Term Definition Term Definition AC Alternating Current Power Factor ratio of true to apparent power Amperes unit of current or rate at flow of

electricity. Watthour unit of electrical work; indicates

expenditure of electrical power of one watt for one hour.

Volt unit of electromotive force Horsepower A measure of time rate of doing work; equivalent to raising 33,000-lbs one ft. in one minute. 1 hp = 746 watts

Ohm unit of resistance Torque Formulas: Ohms Law for DC

Current Ohms

Electromotive Force / Resistance Volts / Amperes

NHPx5252T =

DC Direct Current Where: T = Torque (lb-ft) HP = Horsepower N = Speed (RPM)

Volt Amperes unit of apparent power T = F x R Megohm 1,000,000 Ohms Where: F = Force (lbs)

R = Radius (ft) Watt unit of true power

= volt amperes x power factor

To Find Formula Inflow Performance Relationships for

Solution – Gas Drive Wells (Below Bubble Point) Brake HP

Pump%Eff x 3960SpGr HeadFeet x x GPM 2

Pr

Pwf0.80Pr

Pwf0.201Max Qo

Qo

−=

Brake HP Pump%Eff x 136,000

SpGr HeadFeet x x BPD Pr Static Reservoir Pressure at Producing Zone

HP Input (Three Phase) 746

PF x 1.732Volt x x Amp Pwf Flowing Wellbore Pressure at Producing Zone

Qo Production Rate at Pwf HP Input (Three Phase)

KW x 1.34 Qo Max Production Rate at 100% Drawdown, Pwf = 0

Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts

Formulas for Determining Kilowatts, KVA, Horsepower and Amperes Alternating Current

Desired Data Single Phase Three Phase

Kilowatts 1000

Pf x Amps x Volts 1000

Pf x Amps x Volts x 1.732

Kilovolt – Ampere 1000

Amps x Volts 1000

Amps x Volts x 1.732

Horsepower (Output) 100 x 746

Pf x Eff x Amps x Volts 100 x 746

Pf x Eff x Amps x Volts x 1.732

Amperes (When HP is known) HP x Eff x Volts

746 x HP PF x Eff x Volts x 1.732

746 x HP

Amperes (When Kilowatts are known) PF x Volts1000 x Kilowatts

PF x Volts x 1.7321000 x Kilowatts

Vissersr
Stamp
Page 357: Wood Group ESP Catalogue

Abbreviations, Electrical Terms and Definitions Term Definition Term Definition

AC Alternating Current Amperes (Amp) (A)

Unit of current or rate at flow of electricity.

Ohms Law for DC

Current Ohms

Electromotive Force / Resistance Volts / Amperes

API American Petroleum Institute PB Bubble Point Pressure

AR Abrasion Resistant PBTD Plug Back Total Depth ASSY Assembly PIP Pump Intake Pressure BEP Best Efficiency Point PMP Pump BHT Bottom Hole Temperature Power Factor (PF) Ratio of true to apparent power BO Bolt-On PR Reservoir Pressure

BPD Barrels Per Day PSD Pump Setting Depth Pump % Eff Pump Percent Efficiency Brake Horsepower

(BHP) The net effective power of a prime mover PWF Producing Bottom Hole Pressure

BRG Bearing Q Volume Flow Rate

CP Wellhead Casing Pressure Qmin Minimum volumetric flow rate

CONST Construction Qmax Maximum volumetric flow rate CMP Compression Stage SHD Shroud DC Direct Current Sp Gr Specific Gravity DLS Dog Leg Severity SST Stainless Steel

STBPD Stock Tank Barrels Per Day Drift Guaranteed minimum inside diameter of API tubulars STD Standard

EFF Efficiency STGS Stages FLT Floater Stage STL Steel FT Feet TA 338 Series Equipment GLR Gas / Liquid Ratio 400 Series Equipment GOR Gas / Oil Ratio

TD Total Depth

GPM Gallons Per Minute TE 538 Series Equipment GS Gas Separator TF Tubing Friction Loss

TG 513 Series Equipment TH 562 Series Equipment

Horsepower (HP) A measure of time rate of doing work; equivalent to raising 33,000-lbs one ft. in one minute. 1 hp = 746 watts

THD Motors rated for wellbore conditions

HL High Load TJ 675 Series Equipment

HIPR High Pressure TM 862 Series Equipment HSG Housing TN 950 Series Equipment HSS High Strength Shaft TP Wellhead Tubing Pressure

Hz Hertz TVD True Vertical Depth ID Inside Diameter Unit of electromotive force KG Kilograms

Volt ( ) Surface Voltage

KW Kilowatts Volt Amperes Unit of apparent power LBS Pounds M Meters

Watt unit of true power = volt amperes x power factor

MCF Thousand cubic feet MD Measured Depth

Megohm 1,000,000 Ohms

Watt-hour Unit of electrical work; indicates expenditure of electrical power of one watt for one hour.

MMSCF Million cubic feet WC Water Cut MTR Motor

YG ( SGg) Gas Specific Gravity

NO Number YO ( SGo) Oil Specific Gravity

OD Outside Diameter YW ( SGw) Water Specific Gravity

Ohm Unit of resistance

Vissersr
Stamp
Page 358: Wood Group ESP Catalogue

Copyright Wood Group ESP January 2000

ENGINEERING TABLES Electrical Terms and Definitions

Term Definition Term Definition AC Alternating Current Power Factor ratio of true to apparent power Amperes unit of current or rate at flow of

electricity. Watthour unit of electrical work; indicates

expenditure of electrical power of one watt for one hour.

Volt unit of electromotive force Horsepower A measure of time rate of doing work; equivalent to raising 33,000-lbs one ft. in one minute. 1 hp = 746 watts

Ohm unit of resistance Torque Formulas: Ohms Law for DC

Current Ohms

Electromotive Force / Resistance Volts / Amperes

NHPx5252T =

DC Direct Current Where: T = Torque (lb-ft) HP = Horsepower N = Speed (RPM)

Volt Amperes unit of apparent power T = F x R Megohm 1,000,000 Ohms Where: F = Force (lbs)

R = Radius (ft) Watt unit of true power

= volt amperes x power factor

To Find Formula Inflow Performance Relationships for

Solution – Gas Drive Wells (Below Bubble Point) Brake HP

Pump%Eff x 3960SpGr HeadFeet x x GPM 2

Pr

Pwf0.80Pr

Pwf0.201Max Qo

Qo

−=

Brake HP Pump%Eff x 136,000

SpGr HeadFeet x x BPD Pr Static Reservoir Pressure at Producing Zone

HP Input (Three Phase) 746

PF x 1.732Volt x x Amp Pwf Flowing Wellbore Pressure at Producing Zone

Qo Production Rate at Pwf HP Input (Three Phase)

KW x 1.34 Qo Max Production Rate at 100% Drawdown, Pwf = 0

Where HP = Horsepower; GPM = Gallons Per Minute; Sp Gr = Specific Gravity; Pump % Eff = Pump Percent Efficiency BPD = Barrels Per Day; Amp = Amperes; Volt = Surface Voltage; PF = Power Factor; KW = Kilowatts

Formulas for Determining Kilowatts, KVA, Horsepower and Amperes Alternating Current

Desired Data Single Phase Three Phase

Kilowatts 1000

Pf x Amps x Volts 1000

Pf x Amps x Volts x 1.732

Kilovolt – Ampere 1000

Amps x Volts 1000

Amps x Volts x 1.732

Horsepower (Output) 100 x 746

Pf x Eff x Amps x Volts 100 x 746

Pf x Eff x Amps x Volts x 1.732

Amperes (When HP is known) HP x Eff x Volts

746 x HP PF x Eff x Volts x 1.732

746 x HP

Amperes (When Kilowatts are known) PF x Volts1000 x Kilowatts

PF x Volts x 1.7321000 x Kilowatts

Vissersr
Stamp
Page 359: Wood Group ESP Catalogue

Conversion Factors MULTIPLY BY TO OBTAIN MULTIPLY BY TO OBTAIN

Length Weight Feet 0.3048 Meters Kilograms 2.6792 Pounds (Troy) Inches 25.4 Millimeters Tons (Long) 2722.22 Pounds (Troy)

Area Tons (Short) 2430.55 Pounds (Troy) Square Inches 6.4516 Sq. Centimeters Tons (Metric) 1000 Kilograms

Volume Linear Weight Cubic Feet 7.481 Gallons Kgs. / Meter 0.672 Pounds / Foot

0.02832 Cubic Meters Pounds / Foot 1.488 Kgs. / Meter

Cubic Inches 16.387 Cu. Centimeters Pressure Barrels (US Pet.) 5.6146 Cubic Feet Atmospheres 14.7 Pounds / Sq. In.

42 Gallons (US Liq.) 101.32 Kilopascals

0.159 Cubic Meters 29.92 Inches of Mercury

Gallons (Imperial) 1.2009 Gallons (US Liq.) 760 Millimeters of Mercury

Gallons (US Liq.) 231 Cubic Inches Bar 14.5 Pounds / Sq. In.

128 Ounces (US Liq.) 100 Kilopascals

8 Pints (US Liq.) Kilograms / Sq. Cm. 14.22 Pounds / Sq. In.

4 Quarts (US Liq.) 98.07 Kilopascals

Cubic Meters 35.31 Cubic Feet Kilopascals 0.145 Pounds / Sq. In.

6.2898 Barrels (US Pet.) Pounds / Sq. In. 6.895 Kilopascals

Liters 1000 Cu. Centimeters Feet of Water 0.4335 Pounds / Sq. In.

0.001 Cubic Meters 2.989 Kilopascals

Tons (Metric) 36° Crude 7.452 Barrels (US Pet.) Meters of Water 1.422 Pounds / Sq. In.

Volume Ratios 9.806 Kilopascals Cu. Feet / Cu. Foot 5.615 Cu. Feet / Bbl. Density Cu. Meters / Cu. Meter 5.615 Cu. Feet / Bbl. Pounds / Cu. Ft. 16.0184 Kgs. / Cu. Meter

Velocity Pounds / Cu. In. 27.68 Grams / Cu. Cm. Feet / Second 0.3048 Meters / Second Pounds / Gallon 7.48 Pounds / Cu. Ft. Feet / Minute 0.00508 Meters / Second Kgs. / Cu. Meter 0.06243 Pounds / Cu. Ft. Meters / Second 3.2808 Feet / Second Cubic Feet of Water 62.43 Pounds of Water

Meters / Minute 0.05468 Feet / Second Productivity Index Volumetric Flow Rate Bbls/Day / Atm 0.06805 Bbls/Day / PSI

Cubic Feet / Day 0.1781 Barrels / Day 0.001569 Cu. Meter/Day / KPa

0.2831 Cu. Meters / Day Bbls/Day / Bar 0.06895 Bbls/Day / PSI

Barrels / Minute 1440 Barrels / Day 0.00159 Cu. Meter/Day / KPa

228.9 Cu. Meters / Day Bbls/Day / Kg/Cm2 0.07031 Bbls/Day / PSI

Barrels / Hour 24 Barrels / Day 0.001621 Cu. Meter/Day / KPa

3.816 Cu. Meters / Day Bbls/Day / KPa 6.895 Bbls/Day / PSI

Barrels / Day 0.159 Cu. Meters / Day 0.159 Cu. Meter/Day / KPa

Gallons / Minute 34.29 Barrels / Day Bbls/Day / PSI 0.02307 Cu. Meter/Day / KPa

5.451 Cu. Meters / Day Cu. Meter/Day / Atm. 0.4279 Bbls/Day / PSI

Cu. Meters / Hour 150.9 Barrels / Day 0.00987 Cu. Meter/Day / KPa

24 Cu. Meters / Day Cu. Meter/Day / Bar 0.4336 Bbls/Day / PSI

Cu. Meters / Day 6.289 Barrels / Day 0.01 Cu. Meter/Day / KPa

Temperature Cu. Meter/Day / PSI 6.289 Bbls/Day / PSI °Celsius + 17.78 1.8 °Fahrenheit 0.145 Cu. Meter/Day / KPa

°Celsius + 273 1 °Kelvin Cu. Meter/Day / Kg/Cm2 0.4422 Bbls/Day / PSI °Fahrenheit - 32 0.5555 °Celsius 0.01019 Cu. Meter/Day / KPa

°Fahrenheit + 460 1 °Rankin Cu. Meter/Day / KPa 43.35 Bbls/Day / PSI

Torque Power Foot-Pound 1.356 Newton-Meters Horsepower 0.7457 Kilowatts

Vissersr
Stamp