www.wilksir.com infracal tog/tph analyzer, model cvh calibration

36
www.wilksIR.com www.wilksIR.com InfraCal TOG/TPH Analyzer, InfraCal TOG/TPH Analyzer, Model CVH Model CVH Calibration Calibration

Upload: stephanie-williamson

Post on 23-Dec-2015

273 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

www.wilksIR.comwww.wilksIR.com

InfraCal TOG/TPH Analyzer,InfraCal TOG/TPH Analyzer,Model CVHModel CVH

CalibrationCalibration

Page 2: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Calibration OilCalibration Oil

Heavy hydrocarbon Heavy hydrocarbon

No volatilesNo volatiles

No AdditivesNo Additives

Page 3: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Mixing Standards – Mixing Standards – Volume/volumeVolume/volume

ppm ppm Oil Oil SolventSolvent

400400 40ul40ul 10 ml10 ml

300300 30ul30ul 10 ml10 ml

200200 20ul20ul 10 ml10 ml

100100 10 ul10 ul 10 ml10 ml

Page 4: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

First Standard: First Standard: 100 ppm100 ppm

Add 10-ml of solvent Add 10-ml of solvent to the 10-ml to the 10-ml graduated cylindergraduated cylinder

Page 5: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

First Standard: First Standard: 100 ppm100 ppm

Add 10-ml of solvent Add 10-ml of solvent to the 10-ml to the 10-ml graduated cylindergraduated cylinder

Using the syringe Using the syringe add 10 microliters of add 10 microliters of oil to 10-ml of solvent oil to 10-ml of solvent in the graduated in the graduated cylinder cylinder

Page 6: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

First Standard: First Standard: 100 ppm100 ppm Add 10-ml of solvent Add 10-ml of solvent to the 10-ml to the 10-ml graduated cylindergraduated cylinder

Using the syringe Using the syringe add 10 microliters of add 10 microliters of oil to 10-ml of solvent oil to 10-ml of solvent in the graduated in the graduated cylinder cylinder Pour this standard Pour this standard into a vial labeled into a vial labeled “100 ppm”“100 ppm”

Page 7: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

First Standard: First Standard: 100 ppm100 ppm Add 10-ml of solvent Add 10-ml of solvent to the 10-ml to the 10-ml graduated cylindergraduated cylinder

Using the syringe Using the syringe add 10 microliters of add 10 microliters of oil to 10-ml of solvent oil to 10-ml of solvent in the graduated in the graduated cylinder cylinder Pour this standard Pour this standard into a vial labeled into a vial labeled “100 ppm”“100 ppm”

Shake to mixShake to mix

Page 8: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Second Standard: Second Standard: 50 ppm50 ppm

Pour 5-ml of the 100 ppm standard back into Pour 5-ml of the 100 ppm standard back into the the

10-ml graduated cylinder10-ml graduated cylinder

Page 9: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Second Standard: Second Standard: 50 ppm50 ppm

Pour 5-ml of the 100 ppm standard back into Pour 5-ml of the 100 ppm standard back into the the

10-ml graduated cylinder10-ml graduated cylinder

Fill the cylinder to 10-ml with clean solventFill the cylinder to 10-ml with clean solvent

Page 10: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Second Standard: Second Standard: 50 ppm50 ppm

Pour 5-ml of the 100 ppm standard back into Pour 5-ml of the 100 ppm standard back into the the

10-ml graduated cylinder10-ml graduated cylinder

Fill the cylinder to 10-ml with clean solventFill the cylinder to 10-ml with clean solvent

This will cut the 100 ppm standard in half to This will cut the 100 ppm standard in half to be 50 be 50

ppm ppm

Pour this standard into a vial labeled “50 Pour this standard into a vial labeled “50 ppm”ppm”

Shake to mixShake to mix

Page 11: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Third Standard: Third Standard: 25 ppm25 ppm

Pour 5-ml of the 50 ppm standard back into Pour 5-ml of the 50 ppm standard back into the the

10-ml graduated cylinder10-ml graduated cylinder

Fill the cylinder to 10-ml with clean solventFill the cylinder to 10-ml with clean solvent

Page 12: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Third Standard: Third Standard: 25 ppm25 ppm

Pour 5-ml of the 50 ppm standard back into the Pour 5-ml of the 50 ppm standard back into the 10-ml graduated cylinder10-ml graduated cylinder

Fill the cylinder to 10-ml with clean solventFill the cylinder to 10-ml with clean solvent

This will cut the 50 ppm standard in half to be 25 This will cut the 50 ppm standard in half to be 25 ppmppm

Pour this standard into a vial labeled “25 ppm”Pour this standard into a vial labeled “25 ppm”

Page 13: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Calibration to Prepared Calibration to Prepared StandardsStandards

Make sure InfraCal has been Make sure InfraCal has been on for 1 houron for 1 hour

Make sure cuvette is cleanMake sure cuvette is clean Zero InfraCalZero InfraCal

Page 14: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

ZeroingZeroing Fill the cuvette with clean solvent and Fill the cuvette with clean solvent and

place in the sample stage with the place in the sample stage with the frosted side facing front. frosted side facing front.

Page 15: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

ZeroingZeroing Press and hold the Press and hold the ZEROZERO button until button until

the display reads the display reads bALbAL..

RecallZERO CAL

RUN

bAL

Page 16: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

ZeroingZeroing

RecallZERO CAL

RUN

1.267

A multiplier value to 3 decimal places will A multiplier value to 3 decimal places will be displayed when zero is established. be displayed when zero is established. The actual value is only of interest when The actual value is only of interest when reporting problems to the factoryreporting problems to the factory

Page 17: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

ZeroingZeroing

RecallZERO CAL

RUN

00

Press Press RUNRUN. The display should read 00 . The display should read 00 ++ 02 If not, repeat the zero process 02 If not, repeat the zero process

Page 18: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Calibration to Prepared Calibration to Prepared StandardsStandards

Run each standard at least 3 times on Run each standard at least 3 times on the the

InfraCalInfraCal

Average results for each standardAverage results for each standard

Enter averaged results under the “A” in Enter averaged results under the “A” in the the

manual on page 13 or 14 and the manual on page 13 or 14 and the corresponding calibration value in the C corresponding calibration value in the C columncolumn

Page 19: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Example Calibration TableExample Calibration Table

AA

AbsorbanceAbsorbanceCC

Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Page 20: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Entering Values into EDIT programEntering Values into EDIT program

Make sure Cal Lock switch on the back of the InfraCal is in the “I” position

Page 21: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press the Press the CALCAL button for two button for two seconds, until seconds, until CAL CAL appears on the appears on the displaydisplay

RecallZERO CAL

RUN

CAL

Page 22: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press Press RECALLRECALL until until EditEdit is displayed is displayed

RecallZERO CAL

RUN

Edit

Page 23: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

3

Press Press CAL CAL and the display will read and the display will read n= n=

for a short timefor a short time

RecallZERO CAL

RUN

n=

Page 24: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

3

Set Set n= n= to the number standards to the number standards using the up and down arrowsusing the up and down arrows

RecallZERO CAL

RUN

n=

Page 25: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

3

Set Set n= n= to the number standards to the number standards using the up and down arrows using the up and down arrows (for (for our example it will be 3)our example it will be 3)

RecallZERO CAL

RUN

3

Page 26: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press CAL and the display will read Press CAL and the display will read A01=A01= for a short time for a short time

RecallZERO CAL

RUN

A01

Page 27: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

AbsorbanceAbsorbance Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Using the up and down arrows, scroll to the first absorbance value (for our example it will be 42)

Page 28: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

RecallZERO CAL

RUN

42

Using the up and down arrows, scroll to the first absorbance value (for our example it will be 42)

Page 29: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press Press CALCAL again and the display will read again and the display will read C01=C01=

RecallZERO CAL

RUN

C01

Page 30: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

AbsorbanceAbsorbance Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Using the up and down arrows, scroll to the Using the up and down arrows, scroll to the first first calibration value calibration value (for our example it will be (for our example it will be 25)25)

Page 31: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

RecallZERO CAL

RUN

25

Using the up and down arrows, scroll to the Using the up and down arrows, scroll to the first first calibration value calibration value (for our example it will be (for our example it will be 25)25)

Page 32: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press Press CALCAL and the display will read and the display will read A02=A02= for a short time. Using the up and down for a short time. Using the up and down arrows, scroll to the first calibration value arrows, scroll to the first calibration value (for our example it will be 81)(for our example it will be 81)

AbsorbanceAbsorbance Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Page 33: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press Press CALCAL again and the display will read again and the display will read C02=C02= Scroll this to the second calibration Scroll this to the second calibration valuevalue

AbsorbanceAbsorbance Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Page 34: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Do the same for AO3 and CO3Do the same for AO3 and CO3

AbsorbanceAbsorbance Calibration Calibration StandardStandard

AO1= 42AO1= 42 CO1= 25CO1= 25

AO2= 81AO2= 81 CO2= 50CO2= 50

AO3= 149AO3= 149 CO3= 100CO3= 100

Page 35: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

Press CAL again and the display will read Press CAL again and the display will read IDLEIDLE

RecallZERO CAL

RUN

IDLE

The calibration is now stored and The calibration is now stored and the calibration is now active in the InfraCalthe calibration is now active in the InfraCal

Page 36: Www.wilksIR.com InfraCal TOG/TPH Analyzer, Model CVH Calibration

For questions please contact us at:For questions please contact us at:[email protected], or [email protected], or 203-855-9136

InfraCal TOG/TPH Analyzer,InfraCal TOG/TPH Analyzer,Model CVHModel CVH

CalibrationCalibration