X-Line 101
X-Line BenefitsUptime - improve maintenance accuracy and reduce callbacks
– Diagnostics, protection, and connectivity standardFlexibility – install in more location options
– Lightweight, slim profile– Corrosion resistant– Quiet– Multi-refrigerant
Efficiency – lower usage costs– High efficient scroll compressor and optimized condenser sizing– Floating head pressure control and low condensing ready
X-Line 101
CoreSense TM Diagnostics And Protection
Integrated Technology Delivers Highest Efficiency And Diagnostic Protection
Variable Speed PSC Fan Motors• High Efficiency • Ultra Quiet • Optimizes Air-FlowFor MaximumHeat Transfer
• Meets CEC andNational Standards
Copeland Scroll Compressor Technology• High Efficiency• Ultra Quiet• High Reliability
Unit Sound Levels at Minimum and Maximum Load
•Over Current protection •Flooded Start Protection (“Bump-Start” Logic)
•Incorrect Phase Detection •Discharge Temp. Protection
•High Pressure Lockout •Anti-Short Cycle Time Delay
•Flood-Back Prediction •Digital Fault Code Display / Remote Alarming
•Demand Cooling™ •Over/Under Voltage Protection
X-Line 101X-Line 101
Wide Ambient Operating Range
Maximum Ambient Operating Range Of -40°F To 120°F. System Location, Refrigerant, And Application May Affect Min/Max Operating Capability.
Heated And Insulated ReceiverMaintains Liquid Pressure For Starting In Low AmbientT-Stat Controlled Heater
Check Valve At Inlet Of ReceiverMaintains Pressure Build Up Inside Receiver
Low Ambient Approved Electronics And Sensors
Built In Low Pressure BypassAutomatic Bypass For Low Ambient Startup With Adjustable Time Delay.
Pressure Relief ValvePre-Installed For Zoning Code Compliance
Demand CoolingXFAM/P – Liquid InjectionXFAL – Vapor InjectionKeeps Compressor Cool During High Compression
Variable Speed FanContinually Adjusts For Current Conditions
Large Condenser CoilOptimized For High Ambient Conditions
X-Line 101
X-Line Model GenerationsGeneration Dates Models / BOM Updates
0.1 2008 XJAM / XJAL-002 Initial Release0.2 2010 XJAM / XJAL-012 Added 1-Way Communication1.0 2012 XJAM / XJAL-022 Added Low Ambient Capability1.1 2013 XJAM / XJAL-022 Added Electronic Defrost/EUC2.0 2016 XFAM / XFAP / XFAL-081 Redesigned Electronics / Hinged Door
Vers
ion:
1.1
Vers
ion:
2.0
X-Line 101
Electronic Controls (-022 Models 13F And Newer)
Traditional Defrost Module / Mechanical Low Pressure Control
Electronic Defrost Control / Electronic Pressure Control
• Time Interval Initiate –Time/Temperature Terminate
• 15 Minute Increments / 24 Hr Max interval
• Basic Defrost Functions
• Time Interval Or Real Time Initiate – Time/Temperature Terminate
• Max Duration: 255 Min / 120 Hr Interval
• 7-day/6+1 Day/5+2 Day Programming Options
• Two-Way Communication Capable
• Inaccurate Setting
• Time Consuming Set Up
• Setting Drift Over Time
• Higher Accuracy Than Gages
• <30 Sec. Set Up
• No Drift
X-Line 101
1.0 Electronics Platform“One –Way Communication Board” – Available on -012 /-022 BOM
7-Segment LEDsMain Board ConnectorReset Button
Message Recall Button
Dip Switch Setting
ECT Modbus Connector D0: RS485- (A)C: CommonD1: RS485+ (B)
Terminal Resistor Jumper,On: Terminal Resistor Is EnabledOff: Terminal Resistor Is Disabled
X-Line 101
2.0 Electronics Platform
Pressure Control
Defrost Control
Power Monitoring
Diagnostics And Communications
Consolidated Full System Control
Unit Control
X-Line 101
XJAM Vs. XFAM / XFAPFeature XJAM XFAM / XFAP
Compressor ZX Scroll ZS ScrollService Access Removable Panel Hinged DoorCommunications 1-Way Diagnostics 2-Way CommunicationCapacity Range (@25/90) 14600 – 54610 BTU 12000 – 49500 BTURefrigerants R-404A/507, R-407C/A R-404A/507, R-407C/A
R-22, R-134a, R-448/449Envelope Range -5 to +40 0 to +45 (XFAM)
-25* to +45 (XFAP)Accumulator Not available No Change (XFAM)
Standard (XFAP)Diagnostics / Protection No ChangeSize/Weight/Sound No Change
*Envelope range will vary by refrigerant
X-Line 101
XJAL Vs. XFALFeature XJAL XFAL
Compressor No ChangeService Access Removable Panel Hinged DoorCommunications 1-Way Diagnostics 2-Way CommunicationCapacity Range (@-10/90) No ChangeRefrigerants R-404A/507, R-407C/A R-404A/507, R-407C/A
R-448/449*Envelope Range No ChangeInternal Components No ChangeDiagnostics / Protection No ChangeSize/Weight/Sound No Change
*R-448/449 ratings will follow initial launch
X-Line 101
X-Line Nomenclature / FeaturesX F A M - 0 2 0 Z - T F C - 0 8 1
X =
Out
door
F =
Mul
ti-R
efrig
eran
tJ
= R
-404
A/
R-4
07A
/C
A =
Air
Coo
led
L =
Low
Tem
pM
= M
ediu
m T
emp.
P =
Mul
ti-A
pplic
atio
n
Nom
inal
HP
:01
5 =
1.5
HP
060
= 6
HP
Z =
Scr
oll
Com
pres
sor
CFV
= 2
08/2
30v
1Ph.
60 H
z.TF
C =
208
/230
v 3P
h.60
Hz.
Bill
Of M
ater
ial
Base Model Electrical BOMBOM Features UL
Gen
erat
ion
0.1
–1.
1
Gen
erat
ion
2.0
Rec
eive
r W/ V
alve
Rec
ieve
r Hea
ter /
In
sula
tion
Suc
tion
Valv
e
Liqu
id V
alve
Acc
umul
ator
Oil
Sep
erat
or(L
ow T
emp
Onl
y)
Pre
ssur
e C
ontro
ls
(Adj
usta
ble
low,
Fix
ed
Hig
h)
Def
rost
Con
trol
Filte
r Drie
r
Moi
stur
e In
dica
tor /
Sig
ht
Gla
ss
Cra
nkca
se H
eate
r
Varia
ble
Spe
ed
Con
dens
er F
an
Dem
and
Coo
ling
Low
Tem
p -E
nhan
ced
Vapo
r Inj
ectio
n (E
VI)
Med
/Ext
Med
Tem
p -
Suc
tion
Line
Liq
uid
Inje
cton
One
-Way
Com
mun
icat
ion
Two-
Way
Com
mun
icat
ion
Cor
eSen
se D
iagn
ostic
s /
Pro
tect
ion
List
ed
Rec
ogni
zed
002 X X X Low Temp Only X X X X X X X X X X012 X X X Low Temp Only X X X X X X X X X X X022 X X X X Low Temp Only X X X X X X X X X X X
081 X X X X XFAL, XFAP Only X X X X X X X X X X X
X-Line 101X-Line 101
X-Line Cross Reference1.1 Model 2.0 Model
XJAL-020Z-CFV/TFC-022 XFAL-020Z-CFV/TFC-081XJAL-030Z-TFC-022 XFAL-030Z-TFC-081XJAL-035Z-CFV-022 XFAL-035Z-CFV-081
XJAL-040Z-CFV/TFC-022 XFAL-040Z-CFV/TFC-081XJAL-050Z-CFV/TFC-022 XFAL-050Z-CFV/TFC-081
XJAL-060Z-TFC-022 XFAL-060Z-TFC-081None XFAM-015Z-CFV-081None XFAM-015Z-TFC-081
XJAM-015Z-CFV-022 XFAM-017Z-CFV-081None XFAM-017Z-TFC-081
XJAM-020Z-CFV/TFC-022 XFAM-022Z-CFV/TFC-081XJAM-030Z-CFV/TFC-022 XFAM-030Z-CFV/TFC-081XJAM-040Z-CFV/TFC-022 XFAM-045Z-CFV/TFC-081XJAM-050Z-CFV/TFC-022 XFAM-050Z-CFV/TFC-081
XJAM-060Z-TFC-022 XFAM-060Z-TFC-081
XFAP models can be crossed in place of XFAM models for an additional cost
New models
New model
X-Line 101
63%
17%
100%92%
0%
20%
40%
60%
80%
100%
Entry Level ExperiencedNo Diagnostics Comfort Alert
How Diagnostics Improve Troubleshooting Accuracy And Warranty
43%
18%22%
92%0%
15%
30%
45%
2002 2003 2004
No Diagnostics Comfort Alert
Service Technician Study Actual Warranty Results
Improved ServiceTechnician Accuracy
Lower “No Defect Found”Warranty Failures
%NDFTechnicianAccuracy
“My main concern is getting the equipment repaired the first time on the first visit. . . “ – Refrigeration Contractor
16
CoreSense CoreSense
X-Line 101X-Line 101
X-Line InstallationController Setup
Simplified Commissioning Allows For Setup in about 1 Minute.
•All installation instructions, diagrams, and guidelines are included in the application bulletin (AE5-1412)
•A quick start guide is supplied with each unit (attached to door), showing how to set the control (also in manual)
•Setup is similar to the EUC
X-Line 101X-Line 101
2.0 Diagnostic Codes
Lockouts Occur After An Adjustable Number Of Errors Within A Set Timeframe. Lockouts Can Be Disabled To Always Allow Auto Restarts
Code Description01 AI1 error (Suction Transducer)02 AI2 error (Condenser Temp Probe)03 AI3 error (Discharge Line Temp Probe)
04 AI4 error (Vapor Inlet Temp Probe)
05 AI5 error (Vapor Outlet Temp Probe)
06 AI6 error (Ambient Temp Probe)07 AI7 error (Liquid Line Temp Probe)
08 Battery error09 Current sensor 1 error10 Current sensor 2 error11 Voltage sensor 1 error12 Voltage sensor 2 error13 Voltage sensor 3 error20 Lost phase error21 Phase sequence error22 Phase Imbalance23 Over current 124 Over current 225 Open run circuit error26 Open start circuit error
Code Description27 Under voltage alarm28 Over voltage alarm29 Compressor Build-in protector trip40 High pressure switch41 Low pressure switch42 High pressure alarm43 Low pressure alarm44 Discharge line temperature alarm46 High condenser temperature alarm47 EXV full open in EVI48 EVI high superheating alarm 49 EVI low superheating alarm50 High side flood back alarm80 RTC warning, date not correct81 RTF warning, communication with clock82 Probe configuration error83 DI configuration error84 Compressor configuration error85 Injection probe configuration error86 EEPROM R/W error (manual)
E=ErrorL=Lockout
Code
X-Line 101
System Protection
Proactive Reactive
• Floodback Prediction• Flooded Start Protection (Bump Start)• Short Cycle Protection• Demand Cooling™• Phase Imbalance Protection• High Condensing Temperature
Protection
• Over Current*• Lost Phase• High Pressure*• High Discharge Temperature*• Incorrect Phase Detection• Open Start Or Open Run Circuit• Over/Under Voltage
Identify Or Protect Against Conditions That May Lead To Compressor Damage
Prevent Compressor Damage From System Or Power Supply Issues
*Can be set to Lockout or auto restart
X-Line 101X-Line 101
Compressor Lockouts
Code Condition Controlling Parameter
Default Setting
Value Range
L20 Lost Phase pEn 5 0 – 15; 0=Always Auto Restart
L21 Reversed Phase - - On power up
L23 Over Current oCn 5 0 – 15; 0=Always Auto Restart
L24 Open Run Circuit oCn 5 0 – 15; 0=Always Auto Restart
L25 Open Start Circuit oCn 5 0 – 15; 0=Always Auto Restart
L26 Under Voltage pEn 5 0 – 15; 0=Always Auto Restart
L27 Over Voltage pEn 5 0 – 15; 0=Always Auto Restart
L40 High Pressure HPn 5 0 – 15; 0=Always Auto Restart
L44 Discharge Line Temp dLn 4 0 – 15; 0=Always Auto Restart
L86 EEPROM (Memory) - - -
Repeated Trips Are Often Indicative Of A Larger System Problem. If A Compressor Is Locked Out, The System Should Be Closely Examined To Determine The Cause Of The Issue.
X-Line 101
Lost Phase Protection
• Monitored by voltage sensing terminals on control module
• Triggered if any phase is not detected• Unit will restart after 3 minutes if phase returns• Unit will lockout if phase is lost more than 5
times in an hour
Error Code: E20 or L20
X-Line 101
Incorrect Phase Protection
• Monitored by voltage sensing terminals on control module
• Triggered if any phase does not lead the next by 120°
• Unit will not start until phase is corrected
Error Code: L21
X-Line 101
Phase Imbalance Protection
• Monitored by voltage sensing terminals on control module
• Triggered if voltage on any phase drops below 10% of the average
• Unit will not start until phase is corrected
Error Code: E22
X-Line 101
Over Current Protection
Comp. Status
With ProtectionWithout ProtectionMotorTemp.
OnOff
OnOff
On
•Over current protection is provided before the compressor overheats and trips on internal thermal protection. This shortens restart times from as long as 45 minutes down to 3 minutes.
•Unit will restart after 3 minutes and lockout if more than 5 trips occur within an hour
Error Code: E23 or L23
X-Line 101
High Pressure LockoutHigh pressure cut-out will stop compressor and restart after 3 minutes.• Fixed cut-out at 440psig, cut-in at 348psig• Lockout after 5 trips within one hour
Error Code: L42
X-Line 101
Discharge Line Temperature ProtectionError Code: E44 or L44
• Monitored by temperature sensor on discharge line located 6” from compressor discharge fitting.
• Compressor shuts down if temperature exceeds 250°f (low temp) or 255°f (medium temp)
• Unit will restart after 3 minutes if temperature drops below 170°F.
• System will lockout if compressor trips more than 4 times in an hour
X-Line 101
Flood Back Prediction• Error will display if high-side superheat (discharge –
condenser temp) is less than 18°F for more than 30 minutes of the last 45 minutes
• Unit will continue to run
Error Code: E50
X-Line 101
Flooded Start Protection (Bump Start)Bump start is a startup process that protects against bearing wear caused by flooded starts (refrigerant absorbed into the oil). The compressor and fans will run for 2 seconds then turn off for 15 seconds repeating this sequence 3 times. Once this sequence is completed, the unit resumes normal operation.The bump start sequence will initiate on first startup, and anytime power is lost and restored. Bump start will also initiate anytime the compressor does not run for more than 4 hours, and the ambient temperature is below 95°F.
X-Line 101
Anti-Short Cycle Protection• Compressor will remain off for 3 minutes after any
compressor shutdown.• Compressor indicator on display will flash during
time delay
X-Line 101
Error Code: L26 or L27• Monitored by voltage sensing terminals on
control module• Compressor stopped if voltage exceeds 10% of
min/max rated voltage for more than 1 second• Unit will restart after 3 minutes if voltage returns• Will lockout if compressor is stopped more than
5 times in an hour
Under/Over Voltage Protection
Power Supply
+10%
-10%
X-Line 101
Smart Crankcase Heater
Crankcase heater operates when:• Ambient temperature < 50°F• Compressor off
X-Line 101
Low Ambient Operation
Receiver heater operates when:• Ambient temperature < 50°F• Compressor off •Receiver temperature thermostat is closed (cut-in: 30°F, cut out: 70°F)
Low pressure control bypass:• Ambient temperature < -20°F
•Controlled by parameter LAS• 6 second duration
•Adjustable with parameter LMO
X-Line 101X-Line 101
Demand Cooling™
Injection Attempts To Maintain Discharge Line Temps Below 225°F (LT) Or 235°F (MT)Electronic Injection Valves (EIV) Control Refrigerant Flow For Optimum Injection
Provides Protection For Out Of Envelope OperationEVI Increases Capacity And Efficiency
Enhanced Vapor Injection Suction Line Liquid Injection
EIVHX
EVI Scroll
TXV
Condenser
Evaporator
EIV
TXV
Condenser
Evaporator
Low Temp Medium Temp
X-Line 101X-Line 101
On-Board Alarm History
Alarm History Retains The Last 50 Alarms With Date/Time Stamp
+ EXIT
Alarm 01 Error 40
Alarm 02 Error 40
X-Line 101
Digital Temperature And Pressure Display (Fast Access Menu)
35
Probe 1 - Pressure
Probe 2 - Temperature
X-Line 101X-Line 101
X-Line Communications
Availability Timing Varies. Product Information And Training Will Be Provided When Available.
ecoSYS Site Supervisor
XWEB Internet Gateway
Available to wholesalers thru Weiss instruments
Available to end users thru retail solutions
CoreSense PCSoftware
Remote Display
Local “On-Site” Visibility And Control Remote “Off-Site” Visibility And Control
Accessory kit thru wholesalers
Accessory kit thru wholesalers
E2 Site Control
Existing installationsV4.08
Works with -081 models onlyControl of -081 models only. Visibility of -012 and -022 models
X-Line 101X-Line 101
X-Line InstallationMounting And Connections
Physical Installation Is Simple And Standardized Across All Models
Mount almost anywhere with optional wall mount brackets or snow legs. Will accept brackets and legs from most mini-split manufacturers.
Easy access hinged door panel allows access to centralized color-coded terminal block for main power, defrost, and accessory connections. Door hinges separate for easy door removal.
External valves with standard 7/8” suction and ½” liquid connections
X-Line 101X-Line 101
AWEF Ratings (Medium Temp)
DOE Minimum AWEF For Outdoor MT Equipment: 7.6
MT MTUnit Model Compressor Refrigerant BTU AWEF Unit Model Compressor Refrigerant BTU AWEF
XFAM-015Z ZS09KAE
22 12,400 10.11
XFAM-045Z ZS33KAE
22 36,600 10.9134a 7,870 8.73 134a 24,500 10.38404A 12,500 10.23 404A 40,000 10.7407A 11,800 10.15 407A 38,200 10.22407C 11,200 10.51 407C 36,400 11.17
XFAM-017Z ZS11KAE
22 14,500 10.45
XFAM-050Z ZS38K4E
22 40,100 9.18134a 9,320 9.15 134a 27,500 9.54404A 14,900 10.62 404A 45,800 9.22407A 14,000 10.32 407A 45,000 11.03407C 13,300 10.79 407C 43,100 9.47
XFAM-022Z ZS15KAE
22 19,100 10.51
XFAM-060Z ZS45K4E
22 47,500 9.39134a 12,600 9.69 134a 32,900 9.84404A 20,000 10.75 404A 54,000 9.36407A 18,800 10.6 407A 53,500 9.76407C 17,900 11.06 407C 52,500 9.67
XFAM-030Z ZS21KAE
22 27,900 11.22134a 18,400 10.82404A 28,800 10.75407A 27,200 10.83407C 26,500 11.64
Capacities Rated @ 90°F Ambient / 25°F Evap
X-Line 101
Low Condensing / Envelope Mapping
Low
C
onde
nsin
gN
orm
al
Con
dens
ing
Envelope Map Override
• Default setting allows 70° minimum condensing (80° for XFAL)• 15-20% energy savings for each 10° lower condensing• System EXV needed to handle fluctuation• Adjust parameter MCS to allow low condensing• Control will override to remain within envelope
X-Line 101
Service Kits / Accessories
Service Kits Accessories
• XCM25D controller (943-0214-00)– Supplied without program– One control for all applications– Program supplied on hotkey with each unit– Tracked for warranty
• Master service kit (980-0080-00)
List of all service items is provided with the launch package
• Remote display (143-0023-00)• PC connectivity kit (943-0224-00)• Wall bracket (074-7286-00)• 12” Snow legs (074-7289-00)
X-Line 101
Annual Energy Savings Compared To Traditional Units
XF Outdoor Scroll Vs Standard Units Typical Annual Energy Savings1
Ambient Temperature Zones
Medium Temperature Low Temperature
HP Unit CompressorXFAM kWh
Savings $0.08/kWh $0.12/kWh $0.16/kWh $0.20/kWh HP Unit CompressorXFAL kWh
Savings $0.08/kWh $0.12/kWh $0.16/kWh $0.20/kWh
1.5Hermetic 4,521 $362 $543 $723 $904
2Hermetic 3,775 $302 $453 $604 $755
Scroll 2,561 $205 $307 $410 $512 Scroll 2,892 $231 $347 $463 $578 Semi-Hermetic 5,588 $447 $671 $894 $1,118
2Hermetic 3,713 $297 $446 $594 $743
3Scroll 5,247 $420 $630 $840 $1,049 Scroll 2,288 $183 $275 $366 $458 Semi-Hermetic 5,546 $444 $666 $887 $1,109 Semi-Hermetic 4,100 $328 $492 $656 $820
3Hermetic 5,417 $433 $650 $867 $1,083
4Scroll 5,484 $439 $658 $877 $1,097 Scroll 4,504 $360 $540 $721 $901 Semi-Hermetic 6,994 $560 $839 $1,119 $1,399 Semi-Hermetic 5,739 $459 $689 $918 $1,148
4Hermetic 6,967 $557 $836 $1,115 $1,393
5Scroll 6,900 $552 $828 $1,104 $1,380 Scroll 2,892 $231 $347 $463 $578 Semi-Hermetic 2,050 $164 $246 $328 $410
5Hermetic 9,854 $788 $1,182 $1,577 $1,971
6Scroll 8,889 $711 $1,067 $1,422 $1,778 Scroll 5,369 $430 $644 $859 $1,074 Semi-Hermetic 3,440 $275 $413 $550 $688 Semi-Hermetic 1,209 $97 $145 $193 $242
6 Scroll 13,237 $1,059 $1,588 $2,118 $2,647 Semi-Hermetic 8,046 $644 $966 $1,287 $1,609
1 Estimated kWh savings shown based on simulated unit operation based on average seasonal ambient temperatures in Climate Zone 2. Reciprocating, Scroll, and Semi-Hermetic refer to typical standard condensing units using these compressor technologies, with capacity generally matched to ± 10% of the Copeland Outdoor Scroll unit. Every effort has been made to assure the accuracy of the estimated annual operating cost and savings analysis. Actual energy results may vary by: type of application; load calculation assumptions; proper equipment sizing and matching selections; operational variables; and specific location. Emerson Climate Technologies, Inc. assumes no responsibility for actual energy performance deviations from these estimates, or for damages incurred through the use of the information presented. Detailed Annual Energy Efficiency Ratio (AEER) calculation assumptions, comparative unit and compressor model details, and additional Climate Zone savings estimates are available at: www.EmersonClimate.com/copelandoutdoorunit
Premium To Upgrade Typically < 1 Year PaybackExclusive Technology Only Available From Emerson
http://energycalculator.emersonclimate.com/xline
X-Line 101
Low Temp R-407A Performance
R-407A LTUnit Model Compressor -40 -35 -30 -25 -20 -15 -10 -5 0
90° AmbientXFAL-020Z ZXI06KCE 3,742 4,361 5,147 6,076 7,120 8,254 9,453 10,689 11,937XFAL-030Z ZXI09KCE 5,735 6,537 7,698 8,998 10,422 11,953 13,575 15,269 17,022XFAL-035Z ZXI11KCE 7,173 8,417 9,816 11,356 13,024 14,805 16,685 18,652 20,691XFAL-040Z ZXI14KCE 10,387 11,920 13,592 15,403 17,352 19,439 21,664 24,026 26,526
XFAL-050Z-TFC ZXI15KCE 10,486 12,164 13,982 15,941 18,045 20,296 22,698 25,251 27,960XFAL-050Z-CFV ZXI16KCE 10,791 12,486 14,353 16,392 18,604 20,988 23,545 26,275 29,176
XFAL-060Z ZXI18KCE 13,901 16,078 18,450 21,019 23,784 26,745 29,902 33,255 36,804100° Ambient
XFAL-020Z ZXI06KCE 3,517 4,088 4,831 5,722 6,733 7,840 9,016 10,235 11,471XFAL-030Z ZXI09KCE 5,598 6,551 7,661 8,911 10,285 11,765 13,335 14,979 16,679XFAL-035Z ZXI11KCE 6,722 7,868 9,174 10,625 12,209 13,910 15,716 17,613 19,587XFAL-040Z ZXI14KCE 9,989 11,407 12,959 14,644 16,461 18,411 20,493 22,707 25,052
XFAL-050Z-TFC ZXI15KCE 9,876 11,507 13,265 15,155 17,177 19,336 21,633 24,072 26,654XFAL-050Z-CFV ZXI16KCE 10,385 11,933 13,664 15,578 17,675 19,956 22,419 25,066 27,895
XFAL-060Z ZXI18KCE 13,301 15,272 17,477 19,916 22,590 25,497 28,640 32,016 35,627110° Ambient
XFAL-020Z ZXI06KCE 3,118 3,651 4,362 5,225 6,215 7,305 8,469 9,682 10,916XFAL-030Z ZXI09KCE 5,354 6,239 7,281 8,462 9,767 11,178 12,679 14,253 15,884XFAL-035Z ZXI11KCE 6,235 7,272 8,473 9,825 11,313 12,925 14,646 16,462 18,361XFAL-040Z ZXI14KCE 9,594 10,950 12,433 14,044 15,781 17,646 19,637 21,754 23,997
XFAL-050Z-TFC ZXI15KCE 9,071 10,643 12,331 14,140 16,070 18,125 20,307 22,619 25,064XFAL-050Z-CFV ZXI16KCE 9,586 11,076 12,737 14,570 16,576 18,753 21,102 23,624 26,317
XFAL-060Z ZXI18KCE 12,626 14,472 16,538 18,826 21,334 24,063 27,013 30,184 33,576
Capacities rated at 65°F return gas, 5°F subcooling
X-Line 101
Low Temp R-407C PerformanceR-407C LT
Unit Model Compressor -40 -35 -30 -25 -20 -15 -10 -5 090° Ambient
XFAL-020Z ZXI06KCE 5046 5061 5769 6,433 7,408 8,405 9,407 10,393 11,342XFAL-030Z ZXI09KCE 4,831 5,801 6,882 8,072 9,368 10,766 12,265 13,861 15,551XFAL-035Z ZXI11KCE 6,663 7,698 8,887 10,224 11,705 13,324 15,076 16,957 18,961XFAL-040Z ZXI14KCE 9,664 10,971 12,469 14,151 16,007 18,029 20,208 22,534 24,999
XFAL-050Z-TFC ZXI15KCE 9,603 11,024 12,689 14,570 16,640 18,870 21,233 23,702 26,247XFAL-050Z-CFV ZXI16KCE 7,688 10,396 13,105 15,813 18,522 21,230 23,939 26,647 29,355
XFAL-060Z ZXI18KCE 11,842 13,667 15,707 17,963 20,434 23,121 26,023 29,141 32,475100° Ambient
XFAL-020Z ZXI06KCE 4838 4,946 5,555 6,266 7,060 7,916 8,815 9,736 10,661XFAL-030Z ZXI09KCE 4,430 5,367 6,413 7,566 8,822 10,179 11,633 13,182 14,823XFAL-035Z ZXI11KCE 6,060 7,022 8,137 9,401 10,808 12,355 14,034 15,842 17,773XFAL-040Z ZXI14KCE 9,362 10,612 12,037 13,628 15,377 17,275 19,313 21,481 23,771
XFAL-050Z-TFC ZXI15KCE 9,432 10,647 12,105 13,780 15,644 17,669 19,828 22,091 24,433XFAL-050Z-CFV ZXI16KCE 9,336 11,268 13,335 15,536 17,871 20,339 22,942 25,679 28,549
XFAL-060Z ZXI18KCE 11,146 12,936 14,916 17,085 19,444 21,993 24,731 27,658 30,776110° Ambient
XFAL-020Z ZXI06KCE 4,468 4,741 5,174 5,749 6,445 7,242 8,121 9,061 10,043XFAL-030Z ZXI09KCE 4,015 4,911 5,915 7,023 8,232 9,540 10,942 12,437 14,022XFAL-035Z ZXI11KCE 5,503 6,380 7,411 8,591 9,914 11,376 12,972 14,696 16,544XFAL-040Z ZXI14KCE 8,468 9,718 11,126 12,684 14,383 16,213 18,166 20,233 22,405
XFAL-050Z-TFC ZXI15KCE 8,709 9,793 11,121 12,666 14,400 16,295 18,325 20,460 22,673XFAL-050Z-CFV ZXI16KCE 9,623 11,858 13,870 15,660 17,228 18,574 19,698 20,600 21,280
XFAL-060Z ZXI18KCE 10,391 12,079 13,922 15,920 18,073 20,381 22,844 25,462 28,235
Capacities rated at 65°F return gas, 5°F subcoolingShaded Area: 20°F Max Superheat
X-Line 101
Physical / Electrical Data
Unit ModelCompressor
ElectricalChassis
Size Length Width Height
Refrigerant Connections Receiver Capacity (Lbs @ 90% Volume)
MCA Max Fuse**
Defrost Relay
Rating†(Amps) Ship WeightLiquid Suction R-134a R-22 R-404A R-407A R-407C R-448A* R-449A*
XFAL-020Z-CFV ZXI06KCE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S N/A N/A 9.1 10 10 9.7 9.7 21.55 35 40 246XFAL-020Z-TFC ZXI06KCE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S N/A N/A 9.1 10 10 9.7 9.7 16.18 25 40 246XFAL-030Z-TFC ZXI09KCE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S N/A N/A 9.1 10 10 9.7 9.7 17.18 25 40 246XFAL-035Z-CFV ZXI11KCE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S N/A N/A 9.1 10 10 9.7 9.7 34.05 50 40 272XFAL-040Z-CFV ZXI14KCE-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S N/A N/A 13.4 14.8 14.7 14.2 14.3 40.1 60 40 274XFAL-040Z-TFC ZXI14KCE-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S N/A N/A 13.4 14.8 14.7 14.2 14.3 27.1 45 40 312XFAL-050Z-TFC ZXI15KCE-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S N/A N/A 13.4 14.8 14.7 14.2 14.3 28.85 45 40 323XFAL-051Z-CFV ZXI16KCE-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S N/A N/A 13.4 14.8 14.7 14.2 14.3 44.73 70 40 343XFAL-060Z-TFC ZXI18KCE-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S N/A N/A 13.4 14.8 14.7 14.2 14.3 33.98 50 40 341
XFAM-015Z-CFV ZS09KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 13.55 20 40 218XFAM-015Z-TFC ZS09KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 11.05 15 40 219XFAM-017Z-CFV ZS11KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 16.8 25 40 219XFAM-017Z-TFC ZS11KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 14.05 20 40 219XFAM-022Z-CFV ZS15KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 20.68 35 40 220XFAM-022Z-TFC ZS15KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 14.3 20 40 219XFAM-030Z-CFV ZS21KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 30.05 50 40 236XFAM-030Z-TFC ZS21KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 20.05 30 40 236XFAM-045Z-CFV ZS33KAE-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 37.35 60 40 285XFAM-045Z-TFC ZS33KAE-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 29.98 50 40 280XFAM-050Z-CFV ZS38K4E-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 41.85 70 40 292XFAM-050Z-TFC ZS38K4E-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 28.85 45 40 292XFAM-060Z-TFC ZS45K4E-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 31.98 50 40 299XFAP-015Z-CFV ZS09KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 13.55 20 40 233XFAP-015Z-TFC ZS09KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 11.05 15 40 234XFAP-017Z-CFV ZS11KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 16.8 25 40 234XFAP-017Z-TFC ZS11KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 14.05 20 40 234XFAP-022Z-CFV ZS15KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 20.68 35 40 235XFAP-022Z-TFC ZS15KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 14.3 20 40 234XFAP-030Z-CFV ZS21KAE-PFV 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 30.05 50 40 251XFAP-030Z-TFC ZS21KAE-TF5 1 FAN 16.7 40.5 33.1 1/2 S 7/8 S 10.7 10.5 9.1 10 10 9.7 9.7 20.05 30 40 251XFAP-045Z-CFV ZS33KAE-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 37.35 60 40 300XFAP-045Z-TFC ZS33KAE-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 29.98 50 40 295XFAP-050Z-CFV ZS38K4E-PFV 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 41.85 70 40 307XFAP-050Z-TFC ZS38K4E-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 28.85 45 40 307XFAP-060Z-TFC ZS45K4E-TF5 2 FAN 16.7 40.5 48.9 1/2 S 7/8 S 15.7 15.5 13.4 14.8 14.7 14.2 14.3 31.98 50 40 314
X-Line 101
New Websitehttp://www.emerson.com/CopelandOutdoorUnit
Brochures, Manuals, and QBR’s
X-Line 101
Old Website (Will automatically link to new site after all data is transferred)www.emersonclimate.com/copelandoutdoorunit
Energy Calculator
Brochures, Manuals, and Videos
X-Line 101
Test Parts Ys/T95.2-2001 Aluminum foil
Hydrophilic Coated
Aluminum
Uncoated Aluminum
Condenser Section
W/Coated Aluminum
X-Line 101
900 Hours Salt Spray (Maximum Environment)
Slight Corrosion At Edges
Standard Aluminum
Material Dark Grey / Slight Corrosion
Hydrophilic Aluminum Foil
Material No change
X-Line 101
Coastal Environment Field Test
Unit Installed 12/8/08 Tommy Bahamas Tampa Bay FloridaApproximately 100 Yards From The Gulf Of Mexico.
Unit Inspected 3/24/14 (5 ½ Yrs.) No Issues With Aluminum Fins, Slight Rust On the Cabinet.
Updates Since Inspection:• Screws changed to stainless steel.• Cabinet changed to galvannealed
steel with powder coating• Plastic parts resin changed to more
UV stable material