xcxpl

4
1/196 5 Safety detection solutions Guard switches with lever or spindle operator Plastic, double insulated, turret head, types XCS PL, XCS TL, XCS PR and XCS TR XCS PL with 1 cable entry With rotary operating head, with elbowed lever (flush with rear of switch) or straight lever, for hinged covers and guards Page 1/198 XCS PR with 1 cable entry With rotary operating head, with spindle operator, for hinged covers and guards Page 1/198 XCS TL with 2 cable entries With rotary operating head, with elbowed lever (flush with rear of switch) or straight lever, for hinged covers and guards Page 1/198 XCS TR with 2 cable entries With rotary operating head, with spindle operator, for hinged covers and guards Page 1/198 Presentation 1 2 3 4 5 6 7 8 9 10

Upload: wawin

Post on 18-Jul-2016

2 views

Category:

Documents


0 download

DESCRIPTION

limitatori

TRANSCRIPT

1/196

5 55 5

Safety detection solutionsGuard switches with lever or spindle operatorPlastic, double insulated, turret head, types XCS PL, XCS TL, XCS PR and XCS TR

XCS PL with 1 cable entry With rotary operating head, with elbowed lever (flush with rear of switch) or straight lever, for hinged covers and guards

Page 1/198

XCS PR with 1 cable entry With rotary operating head, with spindle operator, for hinged covers and guards

Page 1/198

XCS TL with 2 cable entries With rotary operating head, with elbowed lever (flush with rear of switch) or straight lever, for hinged covers and guards

Page 1/198

XCS TR with 2 cable entries With rotary operating head, with spindle operator, for hinged covers and guards

Page 1/198

Presentation

1

2

3

4

5

6

7

8

9

10

5 5

1/197

5 5

Safety detection solutionsGuard switches with lever or spindle operatorPlastic, double insulated, turret head, types XCS PL, XCS TL, XCS PR and XCS TR

Environment characteristicsConformity to standards Products EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22-2 n° 14

Machine assemblies EN/IEC 60204-1, EN/ISO 14119Product certifications UL, CSA, BGMaximum safety level (1) PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508Reliability data B10d 5 000 000 (data value for a service life of 10 years can be limited by contact and mechanical wear)Protective treatment Standard version: “TC” and “TH”Ambient air temperature For operation - 25…+ 70°C

For storage - 40…+ 70°CVibration resistance 50 gn (10…500 Hz) conforming to EN/IEC 60068-2-6Shock resistance 50 gn (duration 11 ms) conforming to EN/IEC 60068-2-27Electric shock protection Class 2 conforming to EN/IEC 60536Degree of protection IP 67 conforming to EN/IEC 60529Cable entry XCS Pp: 1 entry tapped M16 x 1.5 for ISO cable gland (clamping capacity 4.5 to 10 mm) or for

n° 11 (Pg 11) cable gland conforming to NF C 68-300 (DIN Pg 11) (clamping capacity 7 to 10 mm) or tapped for 1/2" NPT (USAS B2-1) conduit.XCS Tp: 2 entries tapped M16 x 1.5 for ISO cable gland (clamping capacity 4.5 to 10 mm) or for n° 11 (Pg 11) cable gland conforming to NF C 68-300 (DIN Pg 11) (clamping capacity 7 to 10 mm) or for 1/2" NPT conduit using adaptor DE9 RA1012 in one of the n° 11 tapped entries and a blanking plug in the other.

Materials Polyamide PA66 fibreglass impregnated case. Stainless steel lever and fixings

Contact block characteristicsRated operational characteristics 2 and 3 contact versions

slow breakXCS PL, XCS TL, XCS PR and XCS TR: a AC-15, A300: Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 AAll models: c DC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A conforming to IEC/EN 60947-5-1

Rated insulation voltage 2 and 3 contact versions XCS PL, XCS TL, XCS PR, XCS TR: Ui = 500 V conforming to IEC/EN 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

3 contact version XCS PL, XCS PR: Ui = 400 V degree of pollution 3 conforming to EN/IEC 60947-1 Ui = 300 V conforming to UL 508, CSA C22-2 n° 14

Rated impulse withstand voltage 2 and 3 contact versions XCS PL, XCS TL, XCS PR, XCS TR: Uimp = 6 kV conforming to EN/IEC 60947-5-13 contact version XCS PL, XCS PR: Uimp = 4 kV conforming to EN/IEC 60947-5-4

Positive operation NC contacts with positive opening operation conforming to EN/IEC 60947-5-1, Section 3Resistance across terminals y 30 mW conforming to EN/IEC 60947-5-4Short-circuit protection 2 and 3 contact versions XCS PL, XCS TL, XCS PR, XCS TR: 10 A cartridge fuse type gG (gl)

3 contact version XCS PL, XCS PR: 6 A cartridge fuse type gG (gl)Connection 2 contact version XCS PL, XCS TL, XCS PR, XCS TR:

Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 1.5 mm2 with or without cable end3 contact version XCS PL, XCS PR:

Clamping capacity, min: 1 x 0.34 mm2, max: 1 x 1 mm2 or 2 x 0.75 mm2

Minimum actuation speed 3 contact version 0.01 m/second

Complementary characteristics Tripping angle 5°Mechanical durability 1 million operating cyclesMinimum torque For tripping: 0.1 N.m, for positive opening: 0.25 N.m (XCS PL and XCS PR).

0.45 N.m (XCS TL and XCS TR)(1) Using an appropriate and correctly connected control system.

Electrical durabilityConforming to EN/IEC 60947-5-1 Appendix C.Utilisation categories AC-15 and DC-13.Load factor: 0.5

Maximum operating rate: 3600 operating cycles/hour.

2 and 3 slow break contact versions 3 slow break contact version (XCS PL/PR) AC supply 50/60 Hz a o inductive circuit

DC supply cPower broken in W for 1 million operating cyclesVoltage V 24 48 120

o W 13 9 7

0.5 1 2 3 4 5 100.1

0.2

0.5

1

5

2

43

Ithe

230 V 12/24/48 V

110 V

Current in A

Mill

ions

of o

pera

ting

cycl

es

Mill

ions

of o

pera

ting

cycl

es

Current in A0.5 1 2 3 4 5 10

0.1

0.2

0.5

1

5

2

43

230 V110 V

12/24/48 V

Ithe

Characteristics

1

2

3

4

5

6

7

8

9

10

1/198

5 55 5

Safety detection solutions 0 Guard switches with lever or spindle operatorPlastic, double insulated, turret head (1), types XCS PL, XCS TL, XCS PR and XCS TR1 or 2 cable entries

Type Elbowed lever (flush with rear of switch) Straight lever Spindle

Operator To left Centred To right To right OR to left Centred Length 30 mm (2)

References of complete switches ( NC contact with positive opening operation) with 1 cable entry tapped ISO M16 x 1.52-pole NC + NO break before make, slow break

XCS PL592

XCS PL582

XCS PL572

XCS PL562

XCS PL552

XCS PR552

2-pole NC + NC slow break

XCS PL792

XCS PL782

XCS PL772

XCS PL762

XCS PL752

XCS PR752

3-pole NC + NO + NO (2 NO staggered) slow break

– – – XCS PL862

– XCS PR852

3-pole NC + NC + NO (NO staggered) slow break

– XCS PL982

– XCS PL962

– XCS PR952

Weight (kg) 0.095 0.095 0.095 0.095 0.095 0.105

Operator To left Centred To right To right OR to left Centred Length 30 mm (2)

References of complete switches ( NC contact with positive opening operation) with 2 cable entries tapped ISO M16 x 1.53-pole NC + NO + NO (2 NO staggered) slow break

XCS TL592 XCS TL582

XCS TL572 XCS TL562

XCS TL552

XCS TR552

3-pole NC + NC + NO (NO staggered) slow break

XCS TL792

XCS TL782

XCS TL772

XCS TL762

XCS TL752

XCS TR752

3-pole NC + NC + NC slow break

XCS TL892 XCS TL882

XCS TL872

XCS TL862

XCS TL852 XCS TR852

Weight (kg) 0.145 0.145 0.145 0.145 0.145 0.155

References of complete switches with 1 or 2 cable entries tapped n° 11 (Pg 11)To order a complete switch with 1 or 2 Pg 11 cable entries, replace the last number in the reference (2) by 1. Example: XCS TL592 becomes XCS TL591.

References of complete switches with 1 or 2 cable entries for 1/2" NPT conduitTo order a complete type XCS PLppp or XCS PR ppp switch with 1 cable entry for 1/2" NPT conduit, replace the last number in the reference (2) by 3. Example: XCS PL592 becomes XCS PL593.For a complete switch type XCS TL or XCS TR with 2 entries for 1/2" NPT conduit, use adaptor DE9 RA1012.

Description Sold in lots of 10 Unit reference

Weightkg

1/2" NPT conduit adaptor 10 DE9 RA1012 0.050

(1)Headadjustablein90°stepsthroughout360°.Switchessuppliedwith2additionalself-lockingscrewsforpositivefixingofthehead.(2)Forswitcheswith80mmspindle:replacethe2nd number in the reference (5) by 6. Example: XCS PR561. The weight increases by 0.032 kg.

Other versions: please consult our Customer Care Centre.

1314 22

21

1211

2221

333422

21 1314

3231 13

142221

333422

21 1314

3231 13

142221

1211

2221

3231

References, characteristics

DE9 RA1012

1

2

3

4

5

6

7

8

9

10

5 5

1/199

5 5

Safety detection solutions 0 Guard switches with lever or spindle operatorPlastic, double insulated, turret head, types XCS PL, XCS TL, XCS PR and XCS TR1 or 2 cable entries

Setting-upOperator displacementXCS PLp9p, PLp7p, PLp6p

XCS PLp8p, PLp5p XCS TLp9p, TLp7p, TLp6p

XCS TLp8p, TLp5p XCS PRp5p XCS TRp5p

Functional diagramsXCS PL59p, PL57p, PL56p

XCS PL58p, PL55p XCS TL56p XCS TL58p, TL55p XCS PR55p XCS TR55p

XCS PL79p, PL77p, PL76p

XCS PL78p, PL75p XCS TL79p, TL77p, TL76p

XCS TL78p, TL75p XCS PR75p XCS TR75p

Contact operation XCS PL98p XCS TL87p, TL86p XCS TL88p, TL85p XCS PR85p XCS TR85pG closedH open

Dimensions XCS PR95p

XCS PLppp XCS TLppp

Schemes PL=b, category 1 conforming to EN/ISO 13849-1Example with cable short-circuit protection fuse

(1)1entrytappedISOM16x1.5orPg11(2) 1 entry tapped for 1/2" NPT conduitØ: 2 elongated holes Ø 4.3 x 8.3 on 22 centres,

2 holes Ø 4.3 on 20 centres

(1) 2 entries tapped for n° 11 cable gland(2)2elongatedholesØ4.3x8.3on22centres,

2holesØ4.3on20centres(3)2elongatedholesØ5.3x13.3

XCS PRppp XCS TRppp PL=d, category 3 conforming to EN/ISO 13849-1

Example with 3-pole NC + NO + NO contact with mixed redundancy of the contacts and the associated control relays

(1)2entriestappedISOM16x1.5 or tapped for n° 11 (Pg 11) cable gland

(2)2elongatedholesØ4.3x8.3on22centres, 2holesØ4.3on20centres

(3)2elongatedholesØ5.3x13.3L = 30 (XCS TRp5p) or 80 (XCS TRp6p)

To activate K1, the lever or spindle must be rotated when the supply is switched on. H1: “lever or spindle displaced from initial position” indicator. When used in conjunction with an XPS module and another safety switch, the rotary lever or spindle operator guard switch can provide locking protection to PL=d, category 3 or PL=e, category 4 conforming to EN/ISO 13849-1.

(1) 1 entry tapped for n° 11 cable gland(2) 1 entry tapped for 1/2" NPT conduitØ: 2 elongated holes Ø 4.3 x 8.3 on 22 centres, 2 holes Ø 4.3 on 20 centresL = 30 (XCS PRp5p) or 80 (XCS PRp6p)

21-2213-14

05˚

180˚

10˚

21-2213-14

-90˚-5˚

0+5˚

+90˚

10˚

21-22

33-3413-14

05˚

180˚

10˚

21-22

33-3413-14

-90˚-5˚

0+5˚

+90˚

10˚

21-2213-14

-270˚-5˚

0+5˚

+270˚

10˚

21-22

33-3413-14

-270˚-5˚

0+5˚+5˚

+270˚ +270˚

10˚

11-1221-22

05˚

180˚11-1221-22

-90˚-5˚

0+5˚

+90˚21-22

13-1431-32

05˚

180˚

10˚

21-22

13-1431-32

-90˚+5˚-5˚

+90˚

10˚

011-1221-22

-270˚-5˚

0+5˚

+270˚21-22

13-1431-32

-270˚-5˚

0+5˚

+270˚

10˚

011-12

31-3221-22

5°90° 0

11-12

31-3221-22

5˚180˚

11-12

31-3221-22

-90˚-5˚

0+5˚

+90˚21-22

33-3413-14

-270˚-5˚

0+5˚+5˚

+270˚ +270˚

10˚

011-12

31-3221-22

-270˚-5˚+5˚

+270˚

21-22

13-1431-32

-270˚-5˚

0+5˚

+270˚

10˚

2.5

23.3

5

27.4

2.5

87.5

(1)30

7028

72.543

33

3020/22

16

5.3

3013.2(2)

3020/22

13.5

(2)

12.5 10

8.35

(1)30

7028

72.543

33

52

(3)(2)

40.320/22

16

5.3

12.5

2.5

23.3

5

27.4

2.5

X

F1

O

I

X

2221 13

14

M

32.1

96.2

5

(1)30

28 41.7

5

30

5M4

22138.5

L

20/22

3013.2(2)

3020/22

13.5

(2)

3.2

12.5

(1)30

52

(3) (2)

40.3

20/2212.5

32.1

28 41.7

5

22

138.5

117

5M4

L

3.2

F1

K2

K1 K2

1413

3433

2221

K1

K2

K1

KM1

O

I

KM2H1

K2

K1

KM1

KM2

M

Setting-up, dimensions, schemes

1

2

3

4

5

6

7

8

9

10