xdante-1 dante network audio changeover system
TRANSCRIPT
1 | P a g e
Signature Series
XDANTE-1 DANTE NETWORK AUDIO CHANGEOVER SYSTEM
USER MANUAL V1.0
2 | P a g e
TableofContentsINTRODUCTION .................................................................................................................... 3 IMPORTANT SAFETY PRECAUTIONS ................................................................................ 4
General Safety ............................................................................................................................... 4 Caution ........................................................................................................................................... 4 Power Safety .................................................................................................................................. 5 Installation Notes ........................................................................................................................... 5
PANEL DESCRIPTIONS ....................................................................................................... 6 Front Panel ..................................................................................................................................... 6 Rear Panel ...................................................................................................................................... 7
Setup Instructions ................................................................................................................ 8 Input Mode ..................................................................................................................................... 8 Output Mode ................................................................................................................................ 10
SWITCHING EXAMPLES .................................................................................................... 11 Switching 2 x 64Ch to 32Ch Input Mode ................................................................................... 11 Switching 128Ch to 64Ch Input Mode ....................................................................................... 11 Switching 64Ch to 128Ch Output Mode .................................................................................... 12 Switching 1 x 64Ch to 32Ch Input Mode & 1 x 32Ch to 64Ch Output Mode ........................... 12
CONNECTION EXAMPLES ................................................................................................. 13 Primary only connection example ............................................................................................. 13 Primary & Secondary connection example ............................................................................... 14
TECHNICAL DATA .............................................................................................................. 15 Dimensions .................................................................................................................................. 15 Weight ........................................................................................................................................... 15 Power Supply ............................................................................................................................... 15 Fuses ............................................................................................................................................ 15 Latency ......................................................................................................................................... 15 Dante Ports .................................................................................................................................. 15 Remote Ports ............................................................................................................................... 15
APENDIX A .......................................................................................................................... 16 Autolink Pinout ............................................................................................................................ 16 Remote Pinout ............................................................................................................................. 16
3 | P a g e
INTRODUCTIONCongratulationsonpurchasingtheAutographXDANTE-1Changeoversystem.TheXDANTE-1DANTEChangeoverSystemwasdevelopedasasimpleandefficientwaytoswitchbetweenredundantDANTEsourcesatthepushofabutton.Theunitishousedina1U19”rack-mountcasewithdualredundantswitchmodePSUsasstandard.TheunitallowsforremoteswitchingtoallowsyncwithXUSB-2PCChangeover,orforsimpleexternalbuttoncontrol.Theunitconsistsoftwoindependentlycontrollable64into32channelDanteswitchers.Thesecanbecombinedtoallowswitchingofupto128inputsto64outputs.
• 48KHz24bitoperation.Upto128Inputchannelsto64Outputchannels
• 96KHz24bitoperation.Upto64Inputchannelsto32OutputChannels
ThereisasecondswitchingmodewhichallowsforOutputswitching.Thiswillswitchthefirst32inputstothefirstorsecondblockof32outputs.ShouldyouexperienceanyproblemswithyourXDANTE-1pleasecontact:ServiceDepartmentAutographSoundRecordingLtd2SpringPlaceLondonNW53BAUnitedKingdomTel.+44(0)2074854515Fax.+44(0)[email protected]
4 | P a g e
IMPORTANTSAFETYPRECAUTIONS
Thissectioncontainsdefinitions,warnings,andpracticalinformationtoensureasafeworking
environment.Pleasetaketimetoreadthissectionbeforeinstallingorusingthisunit.Pleasedo
notdisposeoftheseinstructions.
GeneralSafety
• Heedallwarnings.
• Followallinstructions.
• Donotusethisapparatusnearwater.
• Donotexposethisapparatustorainormoisture.
• Cleanonlywithdrycloth.
• Donotblockanyventilationopenings.
• Installinaccordancewiththemanufacturer’sinstructions.
• Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves
orotherapparatus(includingamplifiers)thatproduceheat.
• Adjustmentsoralterationstothisapparatusmayaffecttheperformancesuchthatsafety
and/orinternationalcompliancestandardsmaynolongerbemet.
Caution
• Hazardousvoltagesmaybepresentinsidethisapparatus.
• Donotoperatethisapparatuswiththecoversremoved.
• Toreducetheriskofelectricshock,donotperformanyservicingotherthanthat
containedintheseInstallationInstructionsunlessyouarequalifiedtodoso.Referall
servicingtoqualifiedservicepersonnelandensurethatallpowercordsaredisconnected
whenservicingthisapparatus.
5 | P a g e
PowerSafety
• Thisapparatusisfittedwithauniversalpowersupply,approvedandcertifiedfor
operationinthisapparatus.Therearenouser-replaceablefusesinsidetheunit.
• Multiplepowercordsmaybesuppliedwiththisunit–useonlythepowercord
appropriatetoyourlocalpowerwiring.Alternativepowercordsmaybeusedifrated2.5A
oraboveandfittedwitha3-pinIEC320connector.
• Anexternalover-currentprotectiondeviceisrequiredtoprotectthewiringtothis
apparatus.Thisprotectiondevicemustbeinstalledaccordingtocurrentwiring
regulations.Incertaincountriesthisfunctionissuppliedbyuseofafusedplug.
• Ifanextensionpowercableoradaptorisused,ensurethatthetotalpowerratingofthe
powercableand/oradaptorisnotexceeded.
• Anexternaldisconnectdeviceisrequiredforthisapparatus;adetachablepowercord,as
fittedtothisequipment,isasuitabledisconnectdevice.Thepowersocketusedforthis
apparatusshouldbelocatednearbyandbeeasilyaccessible.
• Allpowercordsmustbedisconnectedtoisolatethisapparatuscompletely.
• Unplugthisapparatusduringanelectricalstormorwhenunusedforlongperiodsoftime.
InstallationNotes
• Wheninstallingthisapparatus,eitherfixitintoastandard19"rackorplacetheapparatus
onasecurelevelsurface.
• Whenthisapparatusisrackmounted,fitallrackscrews.Rackshelvesarerecommended
forthisapparatus.
• Donotoperatethisapparatuswhilstitiscoveredorboxedinanyway.
• Ensurethatnostrainisplacedonthecablesconnectingtothisapparatus.Ensurealsothat
suchcablesarenotplacedwheretheycanbesteppedon,pulledortrippedover.
6 | P a g e
PSUs
Change SwitcherSection1
SwitcherSection2
PANELDESCRIPTIONS
• PSU-Indicatesthecurrentstateofeachpowersupply
• CHANGE-ActivatingreversesthecurrentstateofSwitchers1&2,unlesslockedorisolated
• SwitcherSection1Buttons
‣ 1-ActivatingwillreversethestateofSwitcher1‣ LOCK-Locksswitchertocurrentselection‣ ISO-IsolatesswitcherfromChangebutton/GPI‣ MODE-Turnsswitchertooutputswitchingmode
• SwitcherSection2Buttons
‣ 2-ActivatingwillreversethestateofSwitcher2‣ LOCK-Locksswitchertocurrentselection‣ ISO-IsolatesswitcherfromChangeButton/GPI‣ MODE-Turnsswitchertooutputswitchingmode
FrontPanel
7 | P a g e
SwitcherSection1
SwitcherSection2
PSUs Remote
RearPanel
• PSUs‣ FusedIECmainsinput110-240VAC50-60Hz
• Remote
‣ AUTOLINK-GPI&TallyforremotecontrolofCHANGEbutton.‣ TALLYbutton-AllowsorInhibitsTallybackofCHANGEbutton‣ LOCALCONTROL-GPI&TallyforremotecontrolofCHANGEbutton,Switcher1
&Switcher2
• SwitcherSection1‣ Primary&SecondaryDanteportsforSwitcher1
‣ Gb-IlluminatesifGigabitnetworkpresent‣ Act-IlluminatesifNetworkisactive
• SwitcherSection2
‣ Primary&SecondaryDanteportsforSwitcher2‣ Gb-IlluminatesifGigabitnetworkpresent‣ Act-IlluminatesifNetworkisactive
8 | P a g e
SetupInstructions
InputMode(MODELEDOFF) InputModeswitchesbetweentwoinputsources(upto32Channelsperswitcher)toone32channeloutput.TheoutputoftheswitchercanberoutedtoanyotherDantereceivingdevice.
TheExamplebelowshowstheroutingwithinDanteControllerforaDualRedundantQLabPlaybackSystem.
9 | P a g e
TheoutputsectionshowstheroutingfromtheoutputofSwitcher1totheinputsofadigitalconsole.
10 | P a g e
OutputMode(MODELEDON) OutputModeswitchesupto32inputstoeitheroutputs1-32oroutputs33-64oftheswitcherunit.
11 | P a g e
IP 1-32
IP 33-64
OP 1-32
SFX Mac MainOP Ch 1-32
SFX Mac BackupOP Ch 1-32
IP 1-32
IP 33-64
OP 1-32
Switcher 1
Switcher 2
MixingConsole
IP 1-32
IP 33-64
Music Mac MainOP Ch 1-32
Music Mac BackupOP Ch 1-32
IP 1-32
IP 33-64
OP 1-32
Mac MainOP Ch 1-32
Mac BackupOP Ch 1-32
IP 1-32
IP 33-64
OP 1-32
Mac MainOP Ch 33-64
Mac BackupOP Ch 33-64
Switcher 1
Switcher 2
MixingConsole
IP 1-32
IP 33-64
Switching2x64Chto32ChInputMode
Switching128Chto64ChInputMode
SWITCHINGEXAMPLES
12 | P a g e
IP 1-32
OP 1-32
Switcher 1
MixingConsole
OP 1-32
OP 33-64
OP 33-64
IP 1-32
OP 1-32
Switcher 2
OP 33-64
Right StageIP Ch 1-32
Left StageIP Ch 1-32
Right StageIP Ch 33-64
Left StageIP Ch 33-64
MixingConsole OP 1-32 IP 1-32
OP 1-32
Switcher 2
OP 33-64 Right StageIP Ch 1-32
Left StageIP Ch 1-32
IP 1-32
IP 33-64
OP 1-32
SFX Mac MainOP Ch 1-32
SFX Mac BackupOP Ch 1-32
Switcher 1
MixingConsoleIP 1-32
Switching64Chto128ChOutputMode
Switching1x64Chto32ChInputMode&1x32Chto64ChOutputMode
13 | P a g e
Primaryonlyconnectionexample
CONNECTIONEXAMPLES
14 | P a g e
Primary&Secondaryconnectionexample
15 | P a g e
TECHNICALDATADimensions
• Width19”(483mm)• Height1RU(44mm)• Depth101/4”(260mm)
Weight
• Approximately2KgPowerSupply
• 2x88V-264VAC/47Hz-63HzFuses
• 2x250V-2A(AntiSurge)containedinIECinputconnectorLatency
• @48K-1Sample(.021ms)overdevicelatencyDantePorts 4xNeutriketherConRemotePorts 2xNeutriketherCon
16 | P a g e
Pin Function Action1 +5V/+12V* 2 SwitchCHANGE+3V Groundtoactivate3 4 5 6 7 Switch–CHANGETally Whenactiveprovidesground8 Ground
Pin Function Action1 +5V/+12V* 2 SwitchCHANGE+3V Groundtoactivate3 Switch–2+3V Groundtoactivate4 Switch-2-Tally Whenactiveprovidesground5 Switch–1+3V Groundtoactivate6 Switch-1-Tally Whenactiveprovidesground7 Switch–CHANGETally Whenactiveprovidesground8 Ground
APENDIXA
AutolinkPinout
RemotePinout
*VoltagedependentoninternaljumpersettingofLK1Factorydefaultis5V.