xenon follow spotlights

4
XENON FOLLOW SPOTLIGHTS SUPERSOL 2009SR/e

Upload: others

Post on 21-Jan-2022

13 views

Category:

Documents


0 download

TRANSCRIPT

XENON FOLLOWSPOTLIGHTS

SUPERSOL 2009SR/e

Front hook Hour meter

SUPERSOL® 2009SR/e

Reduction in size and weight

17% of the weight , 5% of the length, and approximately 10% of the height of the followspot body has been reduced.

High output

With our new high precision reflector and lenses, and reviewing and optimizing our optical design, we have increased the output for 20% at φ1.7m, throw distance 30m, min. spot while reducing weight and size.

Cooling function

We have reduced approx. 30% of the surface temperature by improving the cooling function.

Easy operation

We have improved the ideal body balance, re�ned levers, and handles to remarkably upgrade the user-friendliness and impact resistance.

Compact Xenon lamp

We have a new short-Arc type Xenon lamp especially designed and developed for the new SUPERSOL 2009SR/e.This new minimized lamp has enabled us to design a more compact lamp-house.

New douser cutter

A newly designed blade shape of mechanical dimmer provides a more smooth and more uniformed dimming.We have relocated the moun t i ng pos i t i on to t he ou ts ide o f t he lamp-house in order to provide easy maintenance.

Refined design

The chassis integrated structure has allowed us to reduce the screws and re�ne the body design.

New features.

- Front hook- Lamp hour meter

The leading product of our Xebex Xenon Followspot series is the 2000W model, a highly recognized

product in Japan and in the international market.A color temperature of 6000K, a sharp edged light close

to the natural sunlight with a color rendering rate of Ra 95, enables high performance as a followspot for

concert halls,ball rooms, auditorium and outdoor events.

NOTE: *1 Rectifier not included.*2 Comparison ratio with our conventional product.*3 Rate in ( ) is the striking current*4 100V / 200V

Pursuit of QualityUSHIO LIGHTING, INC. has pushed the limits by pursuing a

perpetual quest for development and diligent effort as a

leading manufacturer.We have packaged our newly evolved

features in an even more compact design.Here, we announce

our new �agship followspot model.

RoHS compliant. *1

*2

*2

*2

Product structure

Spot Head / XPS-2009SR/e

Stand / ST-2009/e

Lamp / UXL-20PRS

Rectifier / KSX-80MHXP/K

Dimensions

Spot head

Max ambient temperature

Max surface temperature

Min throw distance

Min fixture space

Operation angle range

Cord

Weight

Dimensions

Noise

Material

Rated voltage

Rated power

Rated current

Total luminous flux

Color temperature

Cooling

AC input voltage

AC input power

Frequency

AC input current

Input cord

Weight

Dimensions

Color

Material

Weight

Dimensions

Xenon short arc lamp

Rectifier

Stand

40℃

90℃

6m

0.3m

10°upward / 45°downward

DC cord: 2PNCT22mm2 x 2C x 5m

Lamp control cord: 2PNCT1.25mm2 x 6C x5m

51kg

W371xH427xD1422mm

< 48 dB or less (distance 1m)

Aluminum casting and iron pipe

XPS-2009SR/e

UXL-20PRS

DC25V

1,750W

DC70A(Max), Actual current range: 56-70A

64,000lm

Forced air cooling 6-9m/s

Average life 1000hrs

About 6,000K

Single phase 100V-120V,173-240V

KSX-80MHXP/K

< 4.2kVA

50/60Hz

42A(100V) / 21A(200V)

14kg

W180xH375xD420mm

Black (ABS Resin)

2PNCT8mm2 x 3C x5mOne touch connecter

SUPERSOL® 2009SR/e

ST-2009/e

Aluminum casting and iron pipe

50kg

W720xH1145~1480xD628mm

Throw distance (m)

25

30

35

40

45

50

60

70

80

1.45φ

1.7φ

2.0φ

2.3φ

2.55φ

2.9φ

3.4φ

4.0φ

4.6φ

SUPERSOL® 2009SR/ePhotometric data

22,400

15,500

11,400

8,700

6,900

5,600

3,800

2,800

2,100

Spot diameter (m) Illumination intensity (lx)

The above spot diameter is minimum data.The maximum spot diameter(compared with minimum data) is 2times zoom ratio.

*3 *4 

Photometric data

Throw distance (m)

Spot diameter

30 40 60 80

1.70 2.30 3.40 4.60

25

1.45

15,50022,400 8,700 3,800 2,100

Illumination intensity (lx)

1534

1422

408220

628 720

360360

262

371

427

166

534

1145

~14

80

3E001- 0806

1E002-1102-1k

Safe Use of the product

The product is intended for use in entertainment. Do not use it for any other application than that of entertainment. It is not for use as

general lighting.

As it generates high voltage only use it as speci�ed.

Failure to observe this could result in electric shock or �re.

Use an appropriate stand (�xing bracket) for the weight of the lamphouse.

Failure to observe this could result in the equipment falling over and causing physical damage or personal injury.

When attaching or installing other equipment ensure the minimum distance is maintained between any in�ammable material and the

periphery of the equipment (excluding the direction of radiation) as indicated on the lamphouse and in the instruction manual.

Failure to observe this could result in �re.

Ensure the adequate distance between the light condensing type lighting apparatus and irradiated face is maintained as indicated on the

lamphouse and in the instruction manual.

Failure to observe this could result in the irradiated object catching �re.

The angle at which the equipment can be used is restricted. Use as indicated on the lamphouse and in the instruction manual.

Failure to observe this could result in damage to the equipment and the Xenon lamp blowing.

When attaching or installing the equipment do not allow the power supply cord to be in contact with the lamphouse of the equipment.

Failure to observe this could result in �re.

This equipment is intended for use indoors. Do not use it outdoors.

Failure to observe this could result in electric shock or �re.

Use the equipment at the maximum ambient temperature or less.

Failure to observe this could result in damage, deformation, �re or the Xenon lamp blowing.

Do not use the equipment anywhere humid or damp.

Failure to observe this could result in electric shock or �re.

Only use the equipment and power supply box (recti�er) within the allowable ambient temperature.

Failure to observe this could result in the Xenon lamp failing to light up or damage being caused.

Do not use the equipment anywhere unstable or near anything �ammable.

Failure to observe this could result in the equipment falling over and causing a �re or personal injury.

Only use the speci�ed Xenon lamp.

Failure to observe this could result in damage to the equipment or the Xenon lamp blowing.

As the equipment emits a slight amount of ultraviolet light avoid exposure to it for long periods of time.

1. Notes on environment / conditions for use

2. Notes on attachment / installationBefore attaching or installing the equipment ensure to thoroughly read the instruction manual and cautionary notes.

After reading store for utilization should the need arise.

Attachment or installation of the equipment should only be carried out by a professional such as a "certi�ed

stage / television lighting engineer".

Failure to observe this could result in malfunction.

Installation should only be carried out by a professional (expert) such as an electrical contractor.

Failure to observe this could result in malfunction.

When attaching and installing the equipment and power supply box (recti�er) they need to have the

appropriate orientation. Attach in accordance with that indicated on the lamphouse and in the

instruction manual.

Failure to observe this could result in damage to the lamphouse, �re or personal injury.

When attaching or installing the equipment ensure measures are implemented to prevent it being

upset and falling by following the instruction manual.

Failure to observe this could result in the equipment falling over and causing physical damage

or personal injury.

When attaching a color changer or other device to the color changer frame, only use a color

changer or other device that is the appropriate weight for the color changer frame.

Failure to observe this could result in physical damage or personal injury.

Avoid stacking power supply boxes (recti�ers) as they could overheat and cause damage or �re.

Ensure to ground (D type grounding) the power supply box (recti�er).

Failure to observe this could result in electric shock or malfunction.

Caution

Warning