xl1500 tn11

Upload: manish

Post on 02-Jun-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 xl1500 tn11

    1/10

    P r o d u c t S u p p o r t G r o u pP.O. Box 368 Herzliya B. 46103 Israel

    Tel: 972-9-960-8222

    Fax: 972-9-960-8299

    www.scitexvision.com

    Techn ica l Note

    Product Scitex XLjet

    T/N # 11

    Subject Loading the Driver Parameters

    Revision

    No. pages 10

    Refer to T/N #

    Written by Vadim Rudy, Eran Hirschberg

    Checked by Eyal Manzoor

    Edited by Sara Stein

    Date 25.11.01

    http://www.scitexvision.com/http://www.scitexvision.com/
  • 8/10/2019 xl1500 tn11

    2/10

  • 8/10/2019 xl1500 tn11

    3/10

    Loading the Driver Parameters

    25/11/01 3/10

    2. Disconnect the Com cable from the Com1 slot in the computers rear side.

    3. Connect the JET 110 cable to the Com slot in the computer.

    Note: All Scitex XLjet machines are equipped with the JET 110 cable that is not used

    for everyday machine operation. The JET 110 cable is only used for testing themachine driver and the driver parameters set loading.

    COM 2(Not used)

    COM 1

    PS/2 sockets

    (keyboard and mouse)

    RIP SCSI connector

    PC AdaptorSCSI connector

    PC Adaptor D-type connector

    Protection plug

    Monitor COM

    Power input socket

    Output socket for monitor

    Network connector

    SCSI connector(not used)

    JET110

  • 8/10/2019 xl1500 tn11

    4/10

    Loading the Driver Parameters

    25/11/01 4/10

    4. Using the machine key, open the Scitex XLjet right cover of the driver unit.

    5. Connect the other end of the JET 110 cable to the driver as shown in the picture

    below.

    6. Close the Scitex XLjet application window.

  • 8/10/2019 xl1500 tn11

    5/10

    Loading the Driver Parameters

    25/11/01 5/10

    7. Locate the YASAKAWA shortcut icon on the desktop and open the software.

    Note: In the first screen that appears you will be prompted to choose an online

    connection.

  • 8/10/2019 xl1500 tn11

    6/10

    Loading the Driver Parameters

    25/11/01 6/10

    8. After you choose an online connection a dialog box will appear, containing

    information about the type of hardware that has been detected by the software.

    Click OK if this information is correct.

    9. The main software window will appear.

    10. Press the Edit Parameters icon.

  • 8/10/2019 xl1500 tn11

    7/10

    Loading the Driver Parameters

    25/11/01 7/10

    11. The display of the current parameters set to the specific driver will appear on thescreen.

    12. Insert the Scitex XLjet software backup CD into the computer CD drive.

  • 8/10/2019 xl1500 tn11

    8/10

    Loading the Driver Parameters

    25/11/01 8/10

    13. Press the Import button.

    14. Browse the CD (SigmaWin Burning files) and locate the Burning files folder.

    15. Choose the relative parameters set.

    Note: There are four parameter set files in the Burning files folder. Each file contains

    a different set of parameters, according to the specific driver (X, Y, Z, T).

  • 8/10/2019 xl1500 tn11

    9/10

    Loading the Driver Parameters

    25/11/01 9/10

    16. Check the Select all box to read all the parameters as shown in the picture

    below.

    17. Press the Write button to load the parameter set to the driver.

  • 8/10/2019 xl1500 tn11

    10/10

    Loading the Driver Parameters

    25/11/01 10/10

    18. After writing the new values into the driver, reset the system by turning OFF and

    ON the relevant driver circuit breaker.

    19. After completing the loading procedure, close the SigmaWin application.

    20. Disconnect both ends of the JET 110 cable from the driver and the computer.

    21. Connect the Com cable to the Com1 connector located in the computers rear

    side (see the picture in step 2).

    22. Close the Scitex XLjet left and right covers.

    23. Open the Scitex XLjet application.

    24. The procedure is complete.

    On