xp1_ts210a_int_6t7088c
TRANSCRIPT
-
8/10/2019 XP1_TS210A_Int_6T7088c
1/4
300 W 45C
capacitive load
+EIB
-BUS/load
select
TS 210Aauto
LN
N L
L
inductive load
16AAC
1
300W
auto
TS210
Aindu
ctiveloa
d
capaciti
veload
6T 7088.c
Variateur 300 W
Notice dinstallation
TS 210A
Prsentation du produit
24 mois contre tous vices de matires ou de fabrication,partir de leur date de production. En cas de dfec-tuosit, le produit doit tre remis au grossiste habituel.La garantie ne joue que si la procdure de retour vialinstallateur et le grossiste est respecte et si aprsexpertise notre service contrle qualitne dtecte pasun dfaut dune mise en uvre et/ou une utilisationnon conforme aux rgles de lart.Les remarques ventuelles expliquant la dfectuositdevront accompagner le produit.
Garantie F
Principe de fonctionnementDans le cadre du systme Tbis TS, levariateur TS 210A permet de faire varier laluminositdune charge incandescente,halogne BT (230V), halogne trs bassetension (TBT 12 V ou 24 V) avec transfor-mateur lectronique ou ferromagntique.En mode Auto, les commandes dallumage,dextinction, de variation et de scnario
de variation, proviennent des modulesdentres du systme .En mode Manu , les ordres dallumageet dextinction sont accessibles par lebouton poussoir en faade du module.
F
Visualisation deltat de la sortie
BP commande localeOn/Off en mode manu
load mode de dcoupage / voyants de signalisation charges associes
select type de charge du type de charge1er appui conduction langle / clignotant - incandescente / halogne 230 V
charge inductive * - halogne TBT (12 V ou 24 V) viatransformateur ferromagntiqueteint adaptla variation.
2me appui coupure langle / teint - incandescente / halogne 230 Vcharge capacitive * - halogne TBT (12 V ou 24 V) viaclignotant transformateur lectronique
3me appui retour au mode de dcoupage prcdement configur.
Configuration du type de chargePar dfaut, aucun type de charge nestspcifi. Lorsque le produit est utilispour la premire fois, les deux leds designalisation du type de charge clignotent.Pour configurer le type de charge, il estncessaire deffectuer les oprationsci-dessous.1.Mettre le module en mode Manu,
sortie teinte.2.Appuyer sur le bouton load select.
Les leds de signalisation du type de
charges sont teintes.3.Slectionner le type de charges par appuis
successifs sur le bouton poussoir loadselect.
4.Confirmer le type de charge slectionneen enfonant le bouton poussoir loadselectpendant 5 secondes.
5.La led associe au type de chargeutilise est maintenant allume.
En cas de surchauffe, la puissancedisponible est automatiquement rduite.Dans ce cas, le voyant de surchauffe /surcharge est allum. Pour remdier cephnomne :
adapter ou diminuer la charge raccordesur la sortie du variateur, diminuer la T du produit et celle de
lenveloppe en insrant des intercalaires(ex : LZ 060) de dissipation de part etdautre du variateur TS 210A et enassurant une bonne ventilation.
Si la temprature est excessive, le variateurTS 210A va se dconnecter de la charge.En cas de court-circuit ou de surchargetrop importante, le voyant de surcharge /surchauffe clignote. Dans ce cas, lacharge nest pas commande.Pour remdier ce problme : vrifier si la sortie est en court-circuit, diminuer la puissance de la charge
raccorde au produit.
* Note 1 : les constructeurs de lampes ou detransformateurs TBT (lectronique ou ferromagn-tique) spcifient dans leur documentation techniquele mode de dcoupage utiliser. Pour les chargesinductives il est impratif dutiliser le mode dedcoupage par conduction langle. Par contre lestransformateurs lectroniques sont gnralementcommands en coupure langle.
Recommandations de mise en uvre1. Installer le module dans le bas de larmoire pour
viter une temprature de fonctionnement trop leve.Nous recommandons de sparer les variateursTS 210A des appareils lectromcaniques de fortespuissances (contacteurs, disjoncteurs) avec desintercalaires de dissipation (ex: LZ 060).
2. Raccorder le module au secteur 230 V et au bus 29 V.Attention : lalimentation du module et lalimentationde la charge doivent tre raccordes en aval dumme dispositif diffrentiel.
3. Raccorder les charges sur la sortie du variateur
TS 210A. Veiller ne pas dpasser la puissancemaximum que peut dlivrer le variateur TS 210A.
4. Configurer le TS 210A pour le type de chargecommand.
5. Suivre les instructions du Guide de Configurationpour raliser les liaisons avec les modulesdentres.
Spcifications techniquesCaractristiques lectriques tension dalimentation : bus 29V consommation vide : 0,5 VA
dissipation maximum du produit : 6 WCaractristiques fonctionnelles Puissance dlivre :
- lampes incandescence et halognes 230 V :20 W 300 W (45 C)
- lampes aux halognes TBT via trans-formateur ferromagntique :20 VA 300 VA (45 C)
- lampes aux halognes TBT via trans-formateur lectronique :25 VA 300 VA (45 C)
Il faut tenir compte du rendementdes transformateurs pour calculerle nombre maximum de lampes.
Modes de dcoupages de phase :- coupure langle- conduction langle
Environnement T de fonctionnement : 0 C +45 C T stockage : -20 C +70 CRaccordement capacit: souple : 1 mm2 6 mm2
rigide : 1,5 mm2 10 mm2
Encombrement : dimensions : 4 modules.
Protection contre la surchauffeou contre les surcharges
Visualisation surcharge ou surchauffe :voyant allumpour surchauffe
voyant clignotant pour surcharge oucourt-circuit
Visualisation dutype de charge
Commutateur Auto/Manu
Led et bouton poussoirdadressage physique
BUS EIB
Bus 29 V Charge
Attention :- Appareil installer uniquement
par un installateur lectricien.- Avant toute utilisation, configurer
imprativement le type de chargecommandsur le produit
- Respecter les rgles dinstallationTBTS.
BP de slectiondu type de charge(load select)
-
8/10/2019 XP1_TS210A_Int_6T7088c
2/4
* Hinweis 1 : Hersteller von Lampen oderNiederspannungs-Transformatoren (elektronischeoder konventionelle) spezifizieren in ihren technischenDokumentationen die Anschnitt-Art, die anzuwendenist. Fr die induktiven Lasten ist es zwingendnotwendig, die Anschnitt-Art auf Phasenanschnitteinzustellen. Im Gegensatz dazu werden dieelektronischen Transformatoren im Allgemeinen mitPhasenabschnitt gesteuert.
load Anschnitt-Art / Anzeige-LED des angeschlossene Last
select Lasttyp Lasttyp1 Tastendruck Phasenanschnitt / blinkt - Glhlampen/Halogenleuchten 230 V
induktive Last * - Niederspannungshalogenleuchten(12 V oder 24 V) beraus konventionellen Transformator.
2 Tastendruck Phasenabschnitt / aus - Glhlampen/Halogenlampen 230 Vkapazitive Last * - Niederspannungshalogenleuchten(12 V oder 24 V) ber elektronischen
blinkt Transformator
3Tastendruck zurck An-/Abschnitt entsprechend vorheriger Einstellung
300 W 45C
capacitive load
+EIB
-BUS/load
select
TS 210Aauto
LN
N L
L
inductive load
6T 7088.c
Dimmer 300 W
16AAC
1
300W
auto
TS210
Aindu
ctiveloa
d
capaciti
veload
Installationsanleitung
TS 210A
Produktbeschreibung
Es gelten die Allgemeinen Geschfstbedingungen der HagerElectro GmbH. bzw. die gesetzliche Regelung.
Garantie D
Funktionsbeschreibung
D
Technische Daten
Sicherheitshinweise:
- Einbau und Montage drfennur durch eine Elektrofachkrafterfolgen.
-Vor Inbetriebnahme den Lasttypkonfigurieren.
- Installationsvorschriften zurSchutzmanahme SELVbeachten.
Im Rahmen des tebis TS-Systems kann derDimmer TS 210A die Helligkeit vonGlhlampen, Halogenleuchten (230 V),Niederspannungs-halogenleuchten (12 Voder 24 V) mit elektronischen oder konventio-nellen Transformatoren dimmen.
Im ModusAuto, kommen die Befehle AUS,Dimmen und Beleuchtungsszenario von den
Eingangsgerten des Systems .Im HandbetriebsmodusManu , werdendie EIN- und AUS-Befehle mit den Tasten aufdem Gert ausgefhrt.
Schaltzustandsanzeigedes Ausgangs
Taster HandbedienungEIN/AUS imHandbetriebsmodusEinstellen des Lasttyps
Werksseitig ist kein Lasttyp eingestellt.Wenn das Gert eingebaut wird, blinken diebeiden LEDs, die den Lasttyp anzeigen.Um den Lasttyp einzustellen, mssen dienachfolgenden Schritte ausgefhrt werden.1.Stellen Sie den Handbetriebsmodus
Manu, ein, der Ausgang ist abgeschaltet2.Bettigen Sie die Taste load select, die
Anzeige-LEDs fr den Lasttyp erlschen.3.Whlen Sie durch mehrfaches Drcken der
Taste load selectden Lasttyp aus.4.Besttigen Sie den ausgewhlten Lasttyp,
indem Sie die Tasteload selectfr5 Sekunden gedrckt halten.
5.Die LED, die zum ausgewhlten Lasttypgehrt, leuchtet jetzt.
Bei bertemperatur wird dieAusgangsspannung automatisch abgesenkt.In diesem Fall leuchtet die LED zur Anzeigevon bertemperatur/berlastung. Um dennormalen Betriebszustand herzustellen:
passen Sie die angeschlossene Last amDimm-Ausgang an oder reduzieren Sie diese.
reduzieren Sie die Temperatur des Gertsoder die des Gehuses, indem SieDistanzstcke (z. B. LZ060) an beidenSeiten des Dimmers einsetzen, um einegute Belftung zu erreichen.
Wenn die Temperatur zu hoch ist, schaltetder TS 210A die Last ab.
Bei einem Kurzschluss oder berlast blinktdie LED bertemperatur/berlastung. In diesemFall wird die Ausgangsspannung abgeschaltet.Um dieses Problem zu lsen:berprfen Sie, ob der Ausgang einen
Kurzschluss hat, reduzieren Sie die Anschlussleistung.
Inbetriebnahmehinweise:1. Betriebstemperatur beachten. Gert im unteren
Bereich des Verteilers montieren. Wir empfehlen, dieDimmer TS 210A von elektromechanischen Gertenmit erhhten Spannungen (Schtze, Leistungsschalter)durch Distanzstcke (z.B. LZ 060) zu trennen.
2. Hilfsspannung 230 V AC und Systemspannunganschlieen.Vorsicht: Die Spannungsversorgung des Moduls undder Laststromkreis mssen an derselben FehlerstromSchutzeinrichtung angeschlossen werden.
3. Schlieen Sie die Lasten an den DimmausgangTS 210A an. Achten Sie darauf, nicht die maximaleLeistung zu berschreiten, die der DimmerTS 210A liefern kann.
4. Konfigurieren Sie den TS 210A fr den Lasttyp,der angesteuert wird.
5. Inbetriebnahmehinweisen der Bedienungs-anleitung folgen.
Schutz gegen bertemperaturoder berlastung
Anzeige der berlast oderbertemperatur:
Anzeige leuchtet bei bertemperaturAnzeige blinkt bei berlast oderKurzschluss
Anzeige des Lasttyps
BetriebsmodusumschalterAuto/Manu
Led undAdressierungstaste
BUS EIB
SystemspannungBus 29 V
LastTaster zumEinstellen desLasttyps(load select)
Elektrische Daten
Versorgungsspannung: 29 V-BusVerbrauch ohne Belastung: 0,5 VA
Verlustleistung: max. 6 WBetriebsdatenAnschliebare Leistungen:
- Glhlampen und Halogenlampen 230 V :20W bis 300W (45 C).
- Niederspannungshalogenleuchten mitkonventionellem Transformator:20VA bis 300VA (45 C).
- Niederspannungshalogenleuchten mitelektronischem Transformator:25VA bis 300VA.
Sie mssen die Leistungsfhigkeit derTransformatoren beachten, um die maxi-male Anzahl von Lampen zu berechnen. Phasenan-/abschnittarten:
- Phasenabschnitt- Phasenanschnitt
Umgebung Betriebstemperatur: 0 C bis +45 C Lagertemperatur: -20 C bis +70 CAnschluss ber Schraubklemmen: flexibel: 1 mm2 bis 6 mm2
massiv: 1,5 mm2 bis 10 mm2
Abmessungen: Groe: 4 PLE.
-
8/10/2019 XP1_TS210A_Int_6T7088c
3/4lectro S.A. - 132, bld dEurope - BP3 - 67 215 Obernai cedex - Tl. 03.88.49.50.50
16AAC
1
300W
auto
TS210
Aindu
ctiveloa
d
capaciti
veload
User instruction
TS 210A
GB
Hager07.2
001
A warranty period of 24 months is offered on hager pro-ducts, from date of manufacture, relating to any material ofmanufacturing defect. If any product is found to be defectiveit must be returned via the installer and supplier (wholesaler).The warranty is withdrawn if :- after inspection by hager quality control dept the device isfound to have been installed in a manner which is contraryto IEE wiring regulations and accepted practice within theindustry at the time of installation.- the procedure for the return of goods has not been followed.Explanation of defect must be included when returning goods.
Warranty GB
Operating principle
300 W 45C
capacitive load
+EIB
-BUS/load
select
TS 210Aauto
LN
N L
L
inductive load
Dimmer 300 W
Product presentationIn association with a Tebis TS system, thedimmer TS 210A allows dimming of 230 Vincandescent lamps, 230 V halogen lamps,VLV halogen lamps (12 V or 24 V) fitted withelectronic or conventional transformers.
In Automode the switching, dimming andlighting scenes are controlled by inputmodules.
In Manu operation the load can only beswitched on or off by using the local pushbutton.
Indication of switch state
Operating push buttonsfor manual operation
load dimming phase / state indicators for associated loads
select load type load type1st press down leading edge / flashing - incandescent / halogen 230 V
inductive load * - VLV halogen (12 V or 24 V) viaconventional transformerswitched off adapted for dimming.
2nd press down lagging edge / switched off - incandescent / halogen 230 Vcapacitive load * - VLV halogen (12 V or 24 V) viaflashing electronic transformer
3rd press down dimming phase previously configurated.
Configurating type of loadThe product is supplied without any defaultload selection. When using the product for thefirst time, the two load type state indicatorswill flash.In order to configure the load type, completethe following actions.1.Put selection switch into position Manu,
output is switched off.2.Press on the button load select.
The state indicators for load type areswitched off.
3.Choose the load type by pressing repeatedlyon the load select.
4.Confirm the load type of your choice bypressing the button load selectfor 5seconds.
5.The state indicator associated to the typeof load selected is now switched on.
In case of overheating, the available releasepower is automatically reduced. In this casethe indicator for overheating/overloading willbe switched on. To solve this problem. : adapt or reduce the connected load on the
output of the dimmer,
decrease the temperature of the device andof the enclosure by using dissipation inserts(eg : LZ 060) and ensure improved ventilationof the enclosure.
If the temperature is too high, the TS 210Adimmer will disconnect.
In case of short circuit or severe overload,the state indicator for overheating/overloadwill flash. In this case, the load is not controlled.To solve this problem : verify if the output of the dimmer is in short
circuit, reduce the power of the load to which the
device is connected.
* Note 1 : manufacturers of lamps or VLV transformers(electronic or conventional) specify in their technicaldocumentation which dimming mode should beused. For inductive loading it is necessary to usethe leading edge mode. However, the electronictransformers are usually controlled with laggingedge mode.
Recommendations before putting intooperation1. Observe operation temperature. Mount device in
lower part of the enclosure.It is recommended to separate the TS 210A dimmersfrom high power electromechanical devices(contactors, MCBs) by using heat dissipationsinserts (eg: LZ 060).
2. Connect the device to the mains power supply230 V and to the bus 29 V.Warning : the supply voltage of the module and ofthe load must be joined downstream from the
same differential protection (RCB).3. Connect the load on the output of the TS 210A
dimmer. Do not exceed the maximum powerof the TS 210A dimmer.
4. Configure the TS 210A for the type of load.
5. Observe the recommendations of the Tebis TSuser instructions.
Overheating and overload protection
Indication of overload or overheating :
switched on for overheatingflashing for overload or short-circuit
Load type indication
Selection of switchAuto/Manu
Led andAdressing button
BUS EIB
Bus 29 V Load
Safety Recommendations:- Installation should only be carried
out by a suitably qualified electrician.
- Before using the device, it has tobe configured by specifying theload to be controlled.
- Observe the installation regulationsof the protection measures SELV.
Press button forconfiguration ofload type(load select)
Technical SpecificationsElectrical specifications
supply voltage : bus 29V
consumption without load : 0,5 VA power dissipation : 6 W
Operation data : power circuit :
- 230V incandescent lamps and halogen lamps:20 W to 300 W (45 C).
- VLV halogen lamps with dimmableconventional transformer:20 VA to 300 VA (45 C).
- VLV halogen lamps with dimmableelectronic transformer :25 VA to 300 VA (45 C)
. The efficiency of the transformer has tobe taken into account to calculate themax. number of controlled lamps. Dimming principles :
- lagging edge- leading edge
Environment operating temperature : 0 C to +45 C storage temperature : -20 C to +70 CConnection capacity: flexible: 1 mm2 to 6 mm2
rigid : 1,5 mm2 to 10 mm2
Dimensions modular unit : 4 modules.
-
8/10/2019 XP1_TS210A_Int_6T7088c
4/4lectro S.A. - 132, bld dEurope - BP3 - 67 215 Obernai cedex - Tl. 03.88.49.50.50Hager07.2
001
16AAC
1
300W
auto
TS210
Aindu
ctiveloa
d
capaciti
veload
Bedieningshandleiding
TS 210A
Waarborg NL
NL
24 maanden tegen elk materiaal- of fabricagegebrek, en ditvanaf de fabricagedatum. In geval van defect, moet hetprodukt, aan uw verdeler overhandigd worden.De waarborg is enkel geldig indien de procedure van terug-zending installateur/verdeler nageleefd wordt en indien naonderzoek door onze controledienst geen enkel gebrek vast-gesteld werd wegens het verkeerd in werking stellen en/ofhet niet gebruiken volgens de regels van de kunst.Eventuele opmerkingen betreffende het gebrek moeten hetprodukt begeleiden.
ProductbeschrijvingWerkingsprincipe
Technische specificaties
Dimmer 300 W
300 W 45C
capacitive load
+EIB
-BUS/load
select
TS 210Aauto
LN
N L
L
inductive load
De dimmermodule TS 210A is in staat delichtsterkte van gloeilampen, halogeenlampen230 V en laagspanningshalogeenlampen metelectronische of gewikkelde transformatorente dimmen.De bevelen van inschakelen, uitschakelen endimmen komen vanuit de ingangsmodulen,die zijn aangesloten op het bussysteem.
De dimmermodule TS 210A beschikt over eenhandbedieningsschakelaar en een schakel-standindicatie voor aan / uit.
Schakelstand-indicatie
Handbedienings-schakelaar aan/uit
load Dimprincipe / LEDs ter indicatie van verbonden belastingen
select belastingsoort de belastingsoort1e druk Fase-aansnijding / knipperend - gloeilamp/halogeenlamp 230 V
inductieve belasting * - ZLS halogeenlamp (12 V of 24 V)via transformator met KTR
uit geschikt voor dimming.
2e druk Fase-afsnijding / uit - gloeilamp/halogeenlamp 230 Vcapacitieve belasting * - halogne TBT (12 V of 24 V) via
knipperend transformator met DETR
3e druk terug naar het vorige geselecteerde dimprincipe.
Instellen van de soort belasting
In geval van oververhitting wordt het beschik-bare vermogen automatisch verminderd.In dit geval staat de LED ter aanduiding vanoververhitting / overbelasting aan. Om ditverschijnsel te voorkomen :
de belasting aangesloten aan de uitgangvan de dimmer aanpassen of verminderen, de temperatuur van het product en van de
kast verminderen door dissipatietussen-stukken (bijv. LZ060) te gebruiken tussende dimmers en door een goede ventilatie inde kast te verzekeren.
De dimmer TS 210A schakelt zich uit van debelasting als de temperatuur overschreden wordt.
In geval van kortsluiting van de belasting ofeen te hoge overbelasting, knippert deoververhittings-, overbelastings-LED. In ditgeval wordt de belasting niet aangestuurd.Om dit probleem te voorkomen : controleren of de uitgang in kortsluiting is, het vermogen van het aangesloten product
verminderen.
* Nota 1 : De fabrikanten van lampen en transforma-toren ZLS (KTR of DETR) geven in hun technischedocumentatie aan welk dimprincipe men dient tegebruiken. Voor inductieve belastingen dientfase-aansnijding te worden gebruikt. De transfor-
matoren DETR kunnen daarentegen over hetalgemeen bedient worden met fase-afsnijding.
Aanbevelingen bij het installeren :1. De module onderaan in de kast installeren om
een te hoge werkingstemperatuur te vermijden.Wij raden u aan de dimmermodule TS 210A tescheiden van componenten met groot vermogen(aardlekschakelaars, motorbeveiligings-schakelaars) met behulp van dissipatietussenstukken(bv: LZ 060).
2. De module aansluiten op het net 230 V en aan debus 29 V.Opgelet : de voeding van de module en de voedingvan de belasting moeten stroomafwaarts verbondenworden met hetzelfde differentieeldispositief.
3. De belastingen aansluiten op de uitgang van dedimmer TS 210A. Let hierbij op dat het maximaledimvermogen van de TS 210A niet wordtoverschreden.
4. Stel de TS 210A in voor de soort belasting.
5. Voor het realiseren van verbindingen met deingangsmodules, de instructies van hetInstallatiedossier volgen.
Beveiliging tegen oververhitting ofoverbelasting
Indicatie van overbelasting ofoververhitting :
LED aan voor oververhittingLED knippert voor overbelastingof kortsluiting
Dimprincipe indicatie
KeuzeschakelaarAuto/Manu
Led en drukknopvoor adressering
BUS EIB
Systeem-spanning 29 V Belasting
Opgepast :- Dit apparaat mag enkel
geplaatst worden door eeninstallateur elektricien.
- Alvorens de dimmermodulete gebruiken, dient deze eerstte worden geconfigureerd doornauwkeurig de aangestuurdebelasting aan te geven.
- De installatieregels ZLVSrespecteren.
Drukknop voorde keuze van debelastingsoort(load select)
Elektrische gegevens
Voedingsspanning: bus 29VVerbruik zonder belasting: 0,5 VA maximale warmteverspreiding van het
product: 6 W
Functies : dimbaar vermogen :
- gloei-en halogeenlampen 230V20W tot 300W (45 C)
- laagspanningshalogeenlampen metconventionele transformator :20VA tot 300VA (45 C).
- laagspanningshalogeenlampen metprimair dimbare transformator :25VA tot 300VA (45 C)
.Voor de berekening van het maximumaantal lampen, dient rekening te wordengehouden met het rendement van detransformator. Dimmer principes :- Fase-afsnijding voor capacitieve belasting
- Fase-aansnijding voor inductieve belastingOmgeving Bedrijfstemperatuur: 0 C tot +45 C Opslagtemperatuur: -20 C tot +70 CAansluiting: capaciteit: flexibel: 1 mm2 tot 6 mm2
massief: 1,5 mm2 tot 10 mm2
Afmeting : 4 modulen.
Het component wordt geleverd zonder dat desoort belasting is aangegeven. Wanneer hetcomponent voor de eerste keer wordtgebruikt, dan knipperen de twee LEDs terindicatie dat de belastingsoort ingesteld dientte worden.Om de belastingsoort in te stellen, dient mende onderstaande instructies uit te voeren.1.De module op stand Manuzetten ;
de uitgang is uit.2.Op de drukknop load selectindrukken.
De LEDs ter indicatie van de belastingsoort
zijn uit.3.Belastingsoort kiezen door achtereenvolgens
op de drukknop load selectte drukken.4.De gekozen belastingsoort bevestigen door
de drukknop load selectgedurende 5seconden in te drukken.
5.De aan de belastingsoort verbonden LEDstaat nu aan.