jebruary 04, 2000
Ref. No.: BNLOO0202-02
United States Nuclear Regulatory Commission 475 Allendale Road .,,
King of Prussia, PA 19406 -M
Attn: Mr. Jim Wiggins
Subject: 3" P.S. Yoke Failure co
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the
Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation
#111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
Mgr. Nuclear Div.
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 C6te de Liesse Tel: (514) 748-7743 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1 G2 Web: www.velan.com
February 04, 2000Ref. No.: BNLOO0202-01
Southern Nuclear Operating Co. 42 Inverness Parkway Birmingham, AL 35242
Attn: Mr. W. Smallwood Mail Code: BIN 016
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
ilsson Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
0j . eI
VELAN Inc. ;ýw' 7007 C6te de Liesse Tel: (514) 748-7743 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1G2 Web: www.velan.com
February 04, 2000Ref. No.: BNLOO0202-12
Southern Nuclear 40 Inveress Parkway P.O. Box 1295 Birmingham, Alabama 35242
Attn: Mr. L. Robertson
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp. .
.H. ilsson Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
v ie
/ý,L
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 Cbte de Liesse Tel: (514) 748-7743 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1G2 Web: www.velan.com Ferar
February 04, Zuuu
Ref. No.: BNL000202-03
Tennessee Valley Authority Browns Ferry Nuclear P.O. Box 2000 Decatur, AL 35609-2000
Attn: Mr. C. Alan Looney
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
tR-Nilsson Mgr. Nuclear Div. c.c. US NRC
VELAN Inc. 7007 C6te de Liesse Tel: (514) 748-7743 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1G2 Web: www.velan.com
F'ebruary 04, 2000Ref. No.: BNLOO0202-04
Niagara Mohawk Power Corp. Nine Mile Point P.O. Box 63 Lycoming, N.Y. 13093
Attn: Mr. Richard Appa, Procurement Eng.
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
iB. sson Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
weit,
oSV�
Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 C~fe dle Liesse Tel: (514) 748-7743 5 Montreal, Quebec Fax: (514) 748-8635 V E LA N Canada H4T 1G2 Web: www.velan.com
February 047M00
Ref. No.: BNL000202-05
Entergy Operations Pilgrim Station - Support Building 600 Rock Hill Road Plymouth, MA 02360
Attn: Mr. Raymond Pace, Mechanical Systems Mgr
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
0 ,c
Velan Valve Corp.
Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 C6te dle Liesse Tel: (514) 748-774350 Mont real, Quebec Fax: (514) 748-8635 V EA Canada H4T IG2 Web: www.velan.com eEL Ar 4
Febru-ary 0, 2
Ref. No.: BNLOO0202-06
Northeast Nuclear Millstone Nuclear Power Station P.O. Box 128 Waterford, CT 06385-0128
Attn: Mr. Steve Sheehan
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
VELAN Inc. 7007 C6te de Liesse Tel: (514) 748-7743 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1G2 Web: www.velan.com
February 04, 2000Ref. No.: BNLOO0202-07
New York Power Authority J.A. Fitzpatrick Nuclear Plant P.O. Box 41 Lycoming, N.Y. 13093
Attn: Mr. Michael Colomb
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
B. N1lsson 1, Mgr. Nuclear Div.
c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
01"e
VELAN Inc. 7007 C6te de Liesse Tel: (514) 748-7743 50 Montreal, Quebec Fax: (514) 748-8635 Canada H4T 1G2 Web: www.velan.com
February 04, 2MU(Ref. No.: BNLOO0202-08
Duke Energy Company Oconee Power Station P.O. Box 219 Seneca, SC 29679
Attn: Mr. Phillip Bowers
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.,
/ii Uss oN 4(gr. Nuclear Div.
c.c. US NCR & SNM Inc.
Celebrating 50 Years of Valve Manufacturing
0 � ce
VELAN Inc. 7007 C~te de Liesse Tel: (514) 748-7743 MnraQuebec Fax: (514) 748-8635 V EA
Caada H4T 1G2 Web: www~velan.com T EA February 04, 2000
Ref. No.: BNLOO0202-09
Florida Power & Light (Turkey Point) 6453 South Ocean Drive Jensen Beach, Florida 34957
Attn: Mr. B.W. Lynch
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve Corp.
ilsson Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 G6te de Liesse Tel: (514) 748-7743 5 Montreal. Quebec Fax: (514) 748-8635 VV EA Canada H-4T 1G2 Web: www.velan.comn T FebrAry0,20
February 04, 2000
Ref. No.: BNLOO0202-10
Consumers Energy Palisades Plant 27780 Blue Star Memorial Highway Covert, Michigan 49043
Attn: Mr. Tom Saarela
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain
Sincerely yours,
Velan Valve
'Mgr. Nuclear Div. c.c. US NRC
Celebrating 50 Years of Valve Manufacturing
VELAN Inc. 7007 C6te de Liesse Tel: (514) 748-7743 50 Montreal, Quebec Fax: (514) 748-8635 V VE L A N Canada H-4T 1 G2 Web: www.velan.com V tebrAryULU
Ref. No.: BNLOO0202-11
Niagara Mohawk Nine Mile Point, Unit 2 P.O. Box 63 Lycoming, N.Y. 13093
Attn: Mr. Dennis Weaver, Mechanical Eng.
Subject: 3" P.S. Yoke Failure
Gentlemen,
Alabama Power, Farley Plant, experienced a problem with a 3" Air Operated Pressure Seal Gate valve, using the Bayonet style Yoke. The Yoke arms on this particular valve broke in the top section of the arms.
Yoke was returned to Velan for examination of the cracked area. An MT was performed together with a full visual inspection. No linear indications were found in the area of the break, nor anywhere else on the Casting. Since this valve is equipped with an Air Operator, we believe that the break may have occurred as a result of metal fatigue due to weight of the Actuator as well as systems vibrations.
Additionally, valves using the Bayonet style Yoke were designed and manufactured during the period when Codes and standards did not define this part as being pressure retaining. The Code Interpretation #111-1-86-58, which clarified this, was issued in 1986. As a result MT was not performed nor were CMTR provided for the Yoke. We discontinued production of Nuclear valves, using this design around 1974.
Our record indicates that we may have furnished Pressure Seal valves, which have the Bayonet style Yoke, to your facility. As a precaution, we recommend that Pressure Seal valves using this style of Yoke be inspected at your convenience. Should you detect any cracks anywhere on the Yoke, we request you pass your finding on to us for further action.
We trust this meets with your acceptance. Should additional assistance be required, please do not hesitate to contact us, we remain