y:foundry 19 (1704.01)7-revit7.5-plot190510 ... · install all sealed penetrations to accomodate...
TRANSCRIPT
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:4
5 P
M
T100
TITLE PAGE
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
Author
Checker
PRELIMINARY SET
FOUNDRY 19655 19TH AVE. NE, MINNEAPOLIS, MN 55418
"ALL MEASUREMENTS ARE APPROXIMATE"
A
B
A
B
G
PATIO TO SIDEWALK
PROPERTY + - 1.67 ACRES89 PROPOSEDPARKING SPACES
(INCLUDEING 6 COMPACTAND 4 ACCESSIBLE
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:4
2 P
M
AS100
MARKETING SITEPLAN
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
JD
Checker
PRELIMINARY SET
1" = 20'-0"AS100
1 Site MARKETING
UP
DN
UP
DN
DN
DN
UP
GENERAL BUILDING PLAN NOTES:
1. GENERAL CONTRACTOR TO COORDINATE THIS PLAN WITH MECHANICAL. ELECTRICAL AND PLUMBING SUBCONTRACTORS AS TO LOCATIONS FOR EQUIPMENT, FIXTURES, METERS, DUCTWORK ETC. NOTIFY ARCHITECT IMMEASDIATELY OF ANY CONFLICTS BETWEEN ARCHITECTURAL DRAWINGS AND MEP SUBCONTRACTORS.
2. REFER TO CODE ANALYSIS (SHEET T101) TO VERIFY TYPES AND LOCATIONS OF REQUIRED FIRE RATINGS. FIRE RATINGS NOTED ON WALL TYPES (SHEET A001) ARE MAXIMUM RATINGS AND MAY EXCEED THE RATINGS THAT ARE ACTUALLY REQUIRED FOR THIS PROJECT.
3. DIMENSOINS AT EXTERIOR WALLS ARE TO THE OUTSIDE FACE OFEXTRIOR SHEATHING OR OUTSIDE FACE OF MASONRY UNLESS NOTED OTHERWISE.
4. DIMENSIONS AT INTERIOR PARTIONS AND CORRIDOR WALLS ARE TO CETERLINE OF FRAMING UNLESS NOTED OTHERWISE. WHERE CLEAR DIMENSIONS ARE NOTED, THESE MUST BE MAINTAINED.
5. DIMENSIONS AT UNIT DEMISING WALLS ARE TO CENTERLINE OF WALL ASSEMBLY AIRSPACE UNLESS NOTED OTHERWISE.
6. DIMENSIONS FOR WINDOWS, DOORS, EQUIPMENT, AND FEATURES ARE TO CENTERLINES. VERIFY WINDOW ROUGH OPENINGS WITH MANUFACTURER.
7. IF ANY DIMENSION IS NOT CLEAR, NOT GIVEN, OR PRESENTS A CONFLICT, NOTIFY ARCHITECT IMMEADIATELY.
8. VERIFY SLAB EDGE LOCATIONS, BRICK AND MASONRY FACE WITH ARCHITECTURAL AND STRUCTURAL DETAILS.
9. REFER TO STRUCTURAL PLANS FOR BEAM, JOIST, HEADER LOCATIONS AND SIZING.
10. ALL OPENINGS CUT, OPENINGS MADE OR EQUIPMENT INSTALLED IN FIRE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE RESTORED, SEALED FIRESTOPPED OR OTHERWISE CONSTRUCTED TO MAINTAIN THE INTEGRITY OF THE FIRE RATING TO THE FULL SATISFACTION OF THE ARCHITECT, ENGINEER AND BUILDING OFFICIAL. THE GENERAL CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR THIS WORK.
11. ALL SIDEWALL PENETRATIONS AND VENTING FOR LAUNDRY, BATH AND KITCHEN EXHAUST SHALL BE INSULATED TO PREVENT CONDENSATION. ALIGN ALL VENTS HORIZONTALLY AND VERTICALLY.
12. THE BUILDING IS REQUIRED TO PASS AIR INFILTRATION TESTING PER THE MINNESOTA ENERGY CODE. ALL PENETRATIONS SHALL BE SEALED APPROPRIATELY TO MEET REQUIREMENTS. INSTALL ALL SEALED PENETRATIONS TO ACCOMODATE WOOD SHRINKAGE.
13. TAPE AND SEAL JOINTS AT MOISTURE CONTROL MEMBRANES.
14. SEAL TOP SIDE OF PRECAST PLANK AND UNDERSIDE OF PRECAST PLANK AT ALL VERTICAL PENETRATIONS.
15. INSTALL INSULATION IN ALL BEDROOM, BATHROOM AND LAUNDRY ROOM WALLS AND WALLS CONTAINING PLUMBING PIPES AS NOTED ON WALL TYPES (SHEET A001).
16. ALL EXPOSED PIPES, VENTS AND CONDUIT PENETRATING WALLS, FLOORS OR CEILINGS SHALL HAVE FINISHED TRIM RINGS (ESCUCHEONS).
17. WHERE ACCESS PANELS ARE REQUIRED FOR EQUIPMENT, UTILITIES OR DEVICES, THOSE PANELS SHALL BE INSTALLED WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN ON THE DRAWINGS. WHEN INSTALLED IN A FIRE RATED ASSEMBLY, ACCESS PANEL MUST BE FIRE RATED TO MATCH RATING OF THAT ASSEMBLY. VERIFY ALL LOCATIONS WITH ARCHITECT BEFORE INSTALLING.
18. PROVIDE BLOCKING IN WALLS FOR MOUNTING EQUIPMENT, RAILS, STOPS, CASEWORK AND ALL OTHER SPECIALTIES AND ACCESSORIES.REFER TO STANDARD MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
19. FINISH FLOOR ELEVATION CHANGE AT DOORS OR MATERIAL TRANSITIONS SHALL NOT EXCEED 1/2" UNLESS NOTED OTHERWISE.
20. EXTERIOR LANDINGS, STOOPS AND PORCHES SHALL BE LEVEL ACROSS DOORWAYS AND SHALL SLOPE AWAY FROM BUILDING 1/4" PER FOOT.
21. REFER TO SHEET A001 FOR WALL TYPES AND ASSEMBLIES.
22. REFER TO SHEET A002 FOR BUILDING SYSTEMS AND ASSEMBLIES.
23. REFER TO FINISH SCHEDULE FOR INTERIOR FINISH MATERIAL TYPES.
24. REFER TO DOOR SCHEDULE FOR INFORMATION ON DOORS AND OPENINGS. ALL DOORS ARE NUMBERED TO KEY WITH DOOR SCHEDULE. NOTIFY ARCHITECT OF ANY DISCREPANCIES
A200
A200
A200
1
4
3
A2002
1 2 3 4 5 6
J
I
H
F
7 8 9 10
E
D
C
B
A
20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0"
17463 SF
TENANT
1050 SF
EXISTINGLOADING
DOCK-
-
PATIO TO SIDEWALKNEW
PATIO DECKNEW
14
' -
7 7
/8"
13
' -
3 7
/8"
DRAINS
A
A
A
A
A
A
A
A
A
A
A
A
G
G
G
G
G
G
G
G
G
G
G
DDDDDDDDDDCCCFFFCCCBBBBBB
GGGGGGGGGGGGGGGG
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
STEEL BEAM ABOVE
1' -
1 1
/2"
6' -
7 1
/2"7
1/8
" 6' -
1 1
/8"9
3/8
" 6' -
3 3
/8"
2' -
0" 7
' -
6"
9"
6' -
3"
9"
6' -
3"
2' -
0" 7
' -
6"
9"
6' -
3"
9"
5' -
6"
2' -
0" 7
' -
6"
8 1
/4" 6' -
2 1
/4"8
1/4
" 6' -
2 1
/4"
3' -
0 1
/2"
3' - 0 1/2"7' - 9"
4' -
9"
10"
4' -
10
"
10"
4' -
10
"1
0"
9"
4' -
9"
9"
4' -
0"
10"
3' -
11
1/4
"
10"
4' -
0"
10"
4' -
0"
9"
4' -
0"
5"
NEW DOOR
DEMOLISH BATH CONFIGURATION
6" LEDGE
17
' - 1
0 1
/2"
X1
2926 SF
OFFICETENANT
9' - 0"
G
3491 SF
OFFICETENANT
-
---
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:3
9 P
M
A101
FIRST FLOOR PLAN
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
JD
Checker
PRELIMINARY SET
1/8" = 1'-0"A101
1 1ST FLOOR
DN
DN
DN
DN
GENERAL BUILDING PLAN NOTES:
1. GENERAL CONTRACTOR TO COORDINATE THIS PLAN WITH MECHANICAL. ELECTRICAL AND PLUMBING SUBCONTRACTORS AS TO LOCATIONS FOR EQUIPMENT, FIXTURES, METERS, DUCTWORK ETC. NOTIFY ARCHITECT IMMEASDIATELY OF ANY CONFLICTS BETWEEN ARCHITECTURAL DRAWINGS AND MEP SUBCONTRACTORS.
2. REFER TO CODE ANALYSIS (SHEET T101) TO VERIFY TYPES AND LOCATIONS OF REQUIRED FIRE RATINGS. FIRE RATINGS NOTED ON WALL TYPES (SHEET A001) ARE MAXIMUM RATINGS AND MAY EXCEED THE RATINGS THAT ARE ACTUALLY REQUIRED FOR THIS PROJECT.
3. DIMENSOINS AT EXTERIOR WALLS ARE TO THE OUTSIDE FACE OFEXTRIOR SHEATHING OR OUTSIDE FACE OF MASONRY UNLESS NOTED OTHERWISE.
4. DIMENSIONS AT INTERIOR PARTIONS AND CORRIDOR WALLS ARE TO CETERLINE OF FRAMING UNLESS NOTED OTHERWISE. WHERE CLEAR DIMENSIONS ARE NOTED, THESE MUST BE MAINTAINED.
5. DIMENSIONS AT UNIT DEMISING WALLS ARE TO CENTERLINE OF WALL ASSEMBLY AIRSPACE UNLESS NOTED OTHERWISE.
6. DIMENSIONS FOR WINDOWS, DOORS, EQUIPMENT, AND FEATURES ARE TO CENTERLINES. VERIFY WINDOW ROUGH OPENINGS WITH MANUFACTURER.
7. IF ANY DIMENSION IS NOT CLEAR, NOT GIVEN, OR PRESENTS A CONFLICT, NOTIFY ARCHITECT IMMEADIATELY.
8. VERIFY SLAB EDGE LOCATIONS, BRICK AND MASONRY FACE WITH ARCHITECTURAL AND STRUCTURAL DETAILS.
9. REFER TO STRUCTURAL PLANS FOR BEAM, JOIST, HEADER LOCATIONS AND SIZING.
10. ALL OPENINGS CUT, OPENINGS MADE OR EQUIPMENT INSTALLED IN FIRE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE RESTORED, SEALED FIRESTOPPED OR OTHERWISE CONSTRUCTED TO MAINTAIN THE INTEGRITY OF THE FIRE RATING TO THE FULL SATISFACTION OF THE ARCHITECT, ENGINEER AND BUILDING OFFICIAL. THE GENERAL CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR THIS WORK.
11. ALL SIDEWALL PENETRATIONS AND VENTING FOR LAUNDRY, BATH AND KITCHEN EXHAUST SHALL BE INSULATED TO PREVENT CONDENSATION. ALIGN ALL VENTS HORIZONTALLY AND VERTICALLY.
12. THE BUILDING IS REQUIRED TO PASS AIR INFILTRATION TESTING PER THE MINNESOTA ENERGY CODE. ALL PENETRATIONS SHALL BE SEALED APPROPRIATELY TO MEET REQUIREMENTS. INSTALL ALL SEALED PENETRATIONS TO ACCOMODATE WOOD SHRINKAGE.
13. TAPE AND SEAL JOINTS AT MOISTURE CONTROL MEMBRANES.
14. SEAL TOP SIDE OF PRECAST PLANK AND UNDERSIDE OF PRECAST PLANK AT ALL VERTICAL PENETRATIONS.
15. INSTALL INSULATION IN ALL BEDROOM, BATHROOM AND LAUNDRY ROOM WALLS AND WALLS CONTAINING PLUMBING PIPES AS NOTED ON WALL TYPES (SHEET A001).
16. ALL EXPOSED PIPES, VENTS AND CONDUIT PENETRATING WALLS, FLOORS OR CEILINGS SHALL HAVE FINISHED TRIM RINGS (ESCUCHEONS).
17. WHERE ACCESS PANELS ARE REQUIRED FOR EQUIPMENT, UTILITIES OR DEVICES, THOSE PANELS SHALL BE INSTALLED WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN ON THE DRAWINGS. WHEN INSTALLED IN A FIRE RATED ASSEMBLY, ACCESS PANEL MUST BE FIRE RATED TO MATCH RATING OF THAT ASSEMBLY. VERIFY ALL LOCATIONS WITH ARCHITECT BEFORE INSTALLING.
18. PROVIDE BLOCKING IN WALLS FOR MOUNTING EQUIPMENT, RAILS, STOPS, CASEWORK AND ALL OTHER SPECIALTIES AND ACCESSORIES.REFER TO STANDARD MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
19. FINISH FLOOR ELEVATION CHANGE AT DOORS OR MATERIAL TRANSITIONS SHALL NOT EXCEED 1/2" UNLESS NOTED OTHERWISE.
20. EXTERIOR LANDINGS, STOOPS AND PORCHES SHALL BE LEVEL ACROSS DOORWAYS AND SHALL SLOPE AWAY FROM BUILDING 1/4" PER FOOT.
21. REFER TO SHEET A001 FOR WALL TYPES AND ASSEMBLIES.
22. REFER TO SHEET A002 FOR BUILDING SYSTEMS AND ASSEMBLIES.
23. REFER TO FINISH SCHEDULE FOR INTERIOR FINISH MATERIAL TYPES.
24. REFER TO DOOR SCHEDULE FOR INFORMATION ON DOORS AND OPENINGS. ALL DOORS ARE NUMBERED TO KEY WITH DOOR SCHEDULE. NOTIFY ARCHITECT OF ANY DISCREPANCIES
A200
A200
A200
1
4
3
A2002
1 2 3 4 5 6
J
I
H
F
7 8 9 10
E
D
C
B
A
6383 SF
OFFICETENANT
-
-
E EE E E E
E
E
E
E
E
E
E
E
EE
EEEH
X1
G
-
---
5' - 6"
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:4
1 P
M
A102
SECOND FLOOR
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
Author
Checker
PRELIMINARY SET
1/8" = 1'-0"A102
1 2ND FLOOR
17463 SF
TENANT
1050 SF
EXISTINGLOADING
DOCK
PATIO TO SIDEWALKNEW
DRAINS
STEEL BEAM ABOVE
NEW DOOR
6" LEDGE
2926 SF
OFFICETENANT
3491 SF
OFFICETENANT
Legend
OFFICE TENANT 1
OFFICE TENANT 2
PRODUCTION SPACE
SPACE
EXISTINGDOCK
100' - 0"
18
0' -
0"
54
' -
4"
19' - 0"
79
' - 1
1"
1189 SF
SPACE
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:4
3 P
M
I103
FIRST FLOORMARKETING
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
JD
PK
PRELIMINARY SET
1/8" = 1'-0"I103
1 1ST FLOOR MARKETING
1/8" = 1'-0"I103
2 LOWER LEVEL MARKETING
Legend
OFFICE TENANT 1
6383 SF
OFFICETENANT
80
' -
8"
80' - 8 1/2"
REVISIONS:
SHEET TITLE
PROJECT NO:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
www.collagearch.com
DATE:
DATE:
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF MINNESOTA.
PETER KEELYREGISTRATION NO: 23570
Collage | architectsArchitectsPete Keely651.472.0050705 Raymond Avenue, Suite #200St. Paul, Minnesota 55114
5/10
/201
9 3:
43:4
5 P
M
I104
SECOND FLOORMARKETING
FOUNDRY 19
Issue Date
Project Number
655 19th Ave. NEMinneapolis, MN 55418
JD
PK
PRELIMINARY SET
1/8" = 1'-0"I104
1 2ND FLOOR T.I.
ROOF