YukonTall Floor Type36,000-120,000 Btu/hMCV Series 50 Hz
YUKON
Split System Air Conditioner
© American Standard Inc. 2006 MS-SLB002-EN
YUKON - Human Comfort SolutionHigh Efficiency• Compact in size for easy
installation into smallspaces.
• Galvanized steel with apowder paint finish forcorrosion resistance.
• Synchronus motor forsupply grille as standardfor better airflow.
ServiceabilityThe unit can be easilyserviced and minimum arearequired just only at the frontafter panel.
Comfort and Reliability• Full Range of Capacity.• Energy Savings.• Washable Filter.• Low Maintenance.• Easy to Service.• Lower Noise.
QualityAll major componentsare individually inspectedand tested, and every unitundergoes a run-test priorto shipment from thefactory.
Trane is proud to present itscomplete line of Tall Floorsplit system air conditionerswith modern design. Thissystem has been not onlycarefully designed andmanufactured according toTrane Worldwide QualityStandards but alsoluxuriously designed toprovide you with years ofcomfortable, convinientcooling with minimal servicerequired and also easy toservice.
The benefits of a systemhave been extended to abroader range of full coolingcapacity, making Yukon theperfect to your new orreplacement application.
MS-SLB002-EN
Time DelayA 3-minute time delayprotects against powerinterruptions and rapidcompressor cycling whichcould damage the airconditioning unit.
Freeze protectionThe freeze protectionfunction will protect coilfrom freezing by turningoff the compressor andoperating the unit at ahigh fan speed to defrostthe coil.
SwingThe auto vertical vaneswing can be selected bypressing the SWING button.
Digital ControlDigital ControlWith microprocessor anddigital technology, Yukonprovides accurate roomtemperature control witha numerical temperaturedisplay.
PowerThe power button is usedto turn the air conditioneron and off operatingaccording to the lastprogram stored in thenon-volatile memory.The display unit will show:• Room temperature in
degrees celcius.• Fan speed.
TemperatureThe TEMP + and - buttonsare used to adjust the settemperature from 15 OCto 30 OC. When the buttonis pressed, the controlunit will display the settemperature (blinking)instead of the roomtemperature. After theprocess is finished, it willrevert back to the roomtemperature within4 seconds.
FanFan speed (Auto, High,Medium, or Low) can beselected by pressing theFAN button.
Auto FanFan speed can be put inthe AUTO mode so that thefan speed will changeautomatically depending onthe difference between theroom and set temperatures.If the difference is large, itwill operate at high speedfor fater cooling. As thedifferencebecomes smaller,the fan speed will bechanged automatically toMedium and then Low asindicated by the positionof the fan speed LEDindicator.
Condensing UnitTTA 075-120
Condensing UnitTTK 048-060
Condensing UnitTTK 036-042
3
Trane has a policy of continuous product and product data improvement and reserves the right to changedesign and specifications without notice.
Literature Order Number: MS-SLB002-EN
Date: Apr 2006
Supersedes: Sep 2004
Stocking Location: Bangkok, Thailand
Product Specifications : 50 HzModels Indoor unit MCV036BB MCV036BB MCV048BB MCV048BB MCV060BB MCV090BB MCV090BB MCV120BB
Outdoor unit TTK536KB TTK536KD TTK042KD TTK048KD TTK060KD TTA075RD TTA100RD TTA120RD
Electrical Data Power Supply V/ph/Hz 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Function Cooling
Performance Data Nominal Capacity Btu/h 36,000 36,000 42,000 48,000 60,000 75,000 100,000 120,000
W 10,551 10,551 12,309 14,068 17,585 21,981 29,307 35,169
Airflow cfm 1,200 1,200 1,600 1,600 2,000 3,000 3,000 4,000
Indoor Units
Expansion Device Capillary Expansion Valve
Fan Motor Type Permanent Split Capacitor
RLA/LRA A 1.78/1.97 1.78/1.97 2.34/2.74 2.34/2.74 2.35/2.75 1.78/1.97 1.78/1.97 2.34/2.74
Control Type Digital Thermostat Standard • • • • • • • •
Features 3 Minute Timer Delay Standard • • • • • • • •
Auto Swing (Vertical Vane) Standard • • • • • • • •
Fan Speed 3 + Auto 3 + Auto 3 + Auto 3 + Auto 3 + Auto 3 + Auto 3 + Auto 3 + Auto
Temperature Setting OC 15 - 30 15 - 30 15 - 30 15 - 30 15 - 30 15 - 30 15 - 30 15 - 30
Programmable Timer Hrs 12 12 12 12 12 12 12 12
Installed Position Wall Mounted - - - - - - - -
Ceiling - - - - - - - -
Low Wall - - - - - - - -
Floor • • • • • • • •
Dimensions Height mm 1,900 1,900 1,900 1,900 1,900 1,900 1,900 1,900
Width mm 600 600 600 600 848 1,196 1,196 1,196
Depth mm 370 370 370 370 400 400 400 400
Weight kg 64 64 68 68 90 136 136 143
Outdoor Units
Compressor Type Type Scroll
RLA/LRA A 19.3/114 7.2/48 8.2/61.8 8.9/65.5 10.0/74.0 13.6/98 20.7/130 22.9/145
Fan Motor Type Type Permanent Split Capacitor
Speed RPM 900 900 900 900 900 700 800 950
RLA/LRA A 1.03/1.79 1.03/1.79 1.03/1.79 0.97/1.76 0.97/1.76 1.95/2.33 1.82/3.07 2.37/7.46
Dimensions Height mm 795 795 795 1,254 1,254 1,050 1,050 1,050
Width mm 1,018 1,018 1,018 988 988 1,060 1,060 1,260
Depth mm 360 360 360 350 350 950 950 1,050
Weight kg 82 80 87 91 94 164 189 240
Piping Connection Type Flare Type Sweat Type
Refrigerant Pipe Size Suction in 3/4 3/4 7/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8
Liquid in 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2
Refrigerant /Charge kg R22/3.4 R22/3.4 R22/3.7 R22/4.7 R22/5.2 R22/Holding Charge
Note:
1. Test at ARI system rating conditions 80 OF-DB/67 OF-WB indoor & 95 OF-DB outdoor.
2. Outdoor unit’s width and depth do not include the size of the mounting feet. For more detail, please see the drawing in the installation manual.
Trane ThailandA business of American Standard Companieswww.trane.com
For more information contact your localdistrict office