zaah teleport
DESCRIPTION
TRANSCRIPT
TELEHOUSE Global Data CentersTELEHOUSE Global Data Centers
EuropeEurope Pac RimPac Rim AmericasAmericasTelehouse Europe(Carrier Neutral)
KDDINW+Colocati
on
Telehouse America (Carrier Neutral)
London(3)
Hamburg
Frankfurt
Paris(2)
Seoul
Beijing
Hong Kong
ShanghaiTaipei
Japan(27)
Bangkok
Singapore
Sydney
Sao Paulo
New York(3)
Los Angeles
Site (sf) IXLondon-E 170,000 LINX, LONAPLondon-W 90,000 LINX, XchangLondon-M 14,000 -
Paris-J 11,000 PARIXParis-V 140,000 Free IX
Frankfurt 40,000 -Hamburg 27,000 XchangeMunich 40,000 -
Site (sf) IXNY-THC 162,000 NYIIXNY-25B 87,000 NYIIXNY-BFC 15,500 -
LA 11,000 LAIIX
Site (sf) IXBeijing * Resale (NAP)
Shanghai * STIXHong Kong 25,000 (HKIX)
Taipei * TWIXSeoul 30,000 (KTIX,DIX)
Bangkok * IIGSingapore * (STIX)
Sydney * -
Munich
TELEHOUSE CENTERMajor Features:
TELEHOUSE custom designed building.
162,000 square feet of space.
24x7 on-site TELEHOUSE security, N+1 redundant power system,
commercial power capacity: (10,000 KVA).
Utilities located in the behind the main data center space.
Multiple telecom providers available: AboveNet, AT&T, Verizon/MCI, KDDI, RCN (Con Edison), OCG, Time Warner,
ISPNet, Digital Providers, Voxel.
Water, Smoke & Fire detection.
Redundant AC units
SAS 70 Type 2 Certified
TELEHOUSE Center
Front Entrance to TELEHOUSE Center
Teleport IITeleport I
Leading Securities Firm’s Data Center
TELEHOUSE Center7 Teleport Drive, SI, NY 10004
Satellite Farm
Ariel view of the Teleport
South Ave
Main GateEntrance
CarrierHotel
CableHead
ManhattanNew Jersey
Telehouse
Telehouse Center
Existing Fiber Ring
Carrier Hotel
Newark AirportCarrier Hotel
Carrier Hotel
Carrier Hotel
Garden City Shirley
Customer
CarrierPOP
USAJPNAsia
C/US,J/US
Cables
Cable Head
Europe
Manasquan & Tuckerton, NJ
TATCables
TELEHOUSE
TeleportAT&T
MH MH
South St.
Victory Blvd.
Physically Diverse Access TELEHOUSE CENTER Advantage
1. Network Diversity
(1) Manhattan bypass route for Global network
(2) 100% physically diverse access to TH Center
2. Low cost Gig-E local connectivity
3. Schedule
- BMI/OCG (Jan.06), Con Edison (March,06)
- AboveNet (2Q, 06)
- TWC. TWT
NJ
NY
Major Features:
Established in 1985 by the Port Authority of NY/NJ as the first TELEPORT in the world.
100-acre office park.
12 miles downwind from Manhattan.
24x7 Front Gate Security provided by Port Authority of NY/NJ Security
requiring 2 picture IDs and access list;
National Guard presence as directed by NY State Governor when Home Land Security Threat escalates.
Redundant power feeds from both Con Edison (NY).
Redundant Voice/Data Carrier entrance into the office park.
Fenced with Infrared Perimeter Security
Front Entrance to the Teleport
Teleport Security Gates
Dedicated Data Center
“WARM OR HOT” Site.Work area for Technical & Admin Staff.Data Backup & Security.Dedicated Telecom Distribution closet per
suite.
FOYER
LOBBYVIP
RECP
PRESENTATION
EXEC
EXECS
TH Office
79
6
5 4
3
2
TELEHOUSE CenterFirst Floor Diagram
Loading dock/
Freight Elevator
DSRGenerators
Ba
tte
rie
sUPS
8Commercial Power
Colocation Space
CAC
1Security
AC Chiller Room
BIZ(Primary)BIZ(Primary)BIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
Main Entrance
7 Teleport Drive
UPS Expansion
TH Office
TH Office
11
10
TELEHOUSE CenterSecond Floor Diagram
LUNCHFOYERROOFSELTELEHOUSE CENTERSECOND FLOORCONF.RM 210(926 sf)CONF.RM 211(858 sf)CONF 212-A(305sf) CONF 213 (660sf)2,172 usf6,942 usf7,635 usf10,192 usf2,101 usfJIHPKCONF 212-B(305sf) 20022003200720112013March 2004Available
Diaster Recovery Personnel Suites
Site J3,500 usf
Colocation Space
Site H - 10,192 usf
Colocation Space
Room 2011 8,642 usfAvailable
Room 20132,000usfAvailableBIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
LOBBYUTILITYTELEHOUSE CENTERTHIRD FLOOR2,895 usfMarch 2004Room 309(574 sf)CNF 310(616 sf)CNF 311-A(600 sf)4,413 usfCNF 311-B(270 sf)CNF 312(257 sf)ELNCNF 313(209sf)300230043010301330053007AvailableAvailable
TELEHOUSE CenterThird Floor Diagram
Diaster Recovery Perso
nnel Suites
Room 3010 6,000 usf Available
2nd Half ‘08
BIZ(Primary)BIZ(Primary)BIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
BIZ(Primary)BIZ(Primary)
Security:
24x7 on-site TELEHOUSE Security Key card access throughout.
Closed circuit television video surveillance – internal & external.
Infrared perimeter & internal motion detectors.
Photo ID (2) required for access to site.
24x7 customer access (access lists).
TELEHOUSE CENTER
TELEHOUSE Center Security Desk
1
Loading Dock:
2 main docks, plus 1 sub-dock.
24x7 customer access, at no cost.
Docks are raised, eliminating need for ramps.
All work monitored by TELEHOUSE security personnel.
Large freight elevator near docks.
TELEHOUSE CENTER
TELEHOUSE Center Loading Dock
2
Customer Assistance Center (CAC):
Control center for all TELEHOUSE America sites.
24x7 Communications Technicians and Infrastructure Engineers on duty.
All customer data and activities are handled via TIMS (TELEHOUSE Information Management System) & accessed by you via the Internet.
Electric Power Quality and Battery monitors in place (7x24)
TELEHOUSE CENTER3
TELEHOUSE Center CAC
Data Signal Room (DSR):
AboveNet, AT&T, Verizon/MCI, KDDI, OCG, Time Warner and others are available to provide telecom service.
All circuit installations monitored by TELEHOUSE.
Circuits are run from DSR to customer telecom closets throughout the site.
Redundant entrance for carriers (South & Victory Blvd)
TELEHOUSE CENTER
TELEHOUSE Center DSR
4
Battery Room:
6 battery strings for back-up.
Capable of handle full center power load for up to 15 minutes.
Batteries designed to immediately provide power in case of commercial power loss, until generators start (8-12 seconds).
TELEHOUSE Center Battery Room
UPS Room:
4 rotary UPSs, 600 KVA each, 3 are operational with 1 in stand-by mode.
Additional UPS upgrade underway.
Even out power source to prevent spikes and brown-outs.
In the event of commercial power loss, UPSs continue to generate power since rotary components spin at such a high rate of speed.
TELEHOUSE Center UPS Room
5
6
Generator Room:
4 diesel-powered generators 1,250 KVA each, 3 are operational with 1 in stand-by mode. Additional generator upgrade underway.
2-day on-site underground supply of fuel, at max power, with multiple vendors on call.
Each generator is kept warm with crankcase heaters to avoid cold starts.
Generator operation is tested monthly, and once per quarter on full power load
(Feb, June, Sept & Dec – 2006)
Member of NYISO & NERA NY Independent System Operators No. American Electric Reliability Assoc.
TELEHOUSE CENTER
TELEHOUSE Center Generator Room
7
Switchgear Room (Commercial Power):
Contains transformers for commercial power with upgrade underway.
Main power grid has Con Edison (NY) and PSE&G (NJ) feeds .
Multiple feeds from local substations.
Power distributed to 3 system set-ups: Critical (customers, emergency, etc.) Essential (office lighting, A/C, etc.) Non-essential (corridor outlets, etc.)
If outage occurs, power is directed to Critical and Essential systems first.
TELEHOUSE CENTER
TELEHOUSE Center Switchgear Room
8
Power Grid System
TELEHOUSE
GOETHALSSUB STATION
GOWANUS(Brooklyn)
COGEN – LINDEN(NJ)PSE&G – LINDEN(NJ)
FRESH KILLSSUB STATION
TELEPORT
345KV
Greenpoint(Brooklyn)
ARTHER KILLGENERATING
PLANT
Chiller (A/C) Room:
Chillers originally supported high cooling requirement of mainframe data centers. Less cooling capacity needed for equipment today so Chillers have been adapted accordingly.
4 water chillers, 3 are operational with 1 in stand-by mode with upgrade underway.
2-day on-site underground supply of condenser water, in the event of municipal water loss.
TELEHOUSE CENTER
TELEHOUSE Center Chiller Room
9
10
TELEHOUSE CENTER
Halon
Smoke Detector
Pre-Action Sprinklers
Data Center & Colocation Spaces:
Fire Protection: Halon in restricted areas. Pre-action sprinklers. Ceiling smoke detectors measure
heat & smoke particle density before releasing water.
Centrally monitored by CAC.
Raised Floor: 2 feet of raised space. Separate cable trays for
communications and power cables to avoid interference.
TELEHOUSE CENTER TELEHOUSE Center Fire Suppression
TELEHOUSE Center Raised Floor
Colocation :
Shared colocation space Open Space (A), Site H & J.
Caged space available.
Access to space from main building corridor.
Equipment moved using maintenance corridor.
10
TELEHOUSE Center Colocation
11