zedge small floor wash zesrpfw- · 1.57" 2.48" 2.48" 0.157" 1.732" floor...

5
1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW- Louver ZESRPLV- Bi-Emission ZESRPBE- WARNING Remote Class II electronic power supply will power the fixture with low voltage. DO NOT CONNECT FIXTURE WITH LINE VOLTAGE. FAILURE TO COMPLY WILL RESULT IN VOID OF WARRANTY. See Fixture Connection (page 2) for more information. To ensure a maximum efficient use of the product, read the instructions before proceeding installment. This fixture must be installed by a licensed and qualified electrician. The installer must comply with NEC and local building codes when installing the fixture Electrical current can cause painful shock, serious injury, or even death. Make sure you turn off the power supply, ground fixture(s), and make sure all electrical connections are correct and secured tightly For use in IP66 installations. Keep the label of the original packaging if any eventual future claims are needed Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 1 of 5 0.44 lbs 24VDC +95°C -13°F 3' Table of Contents Fixture Connection Fixture Installation Distribution of Light Maintenance Support Pg. 2 Pg. 3 Pg. 4 Pg. 5 Pg. 6 ZEDGE Small ZESRP- COD. 2DI2CS00

Upload: others

Post on 20-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZEDGE Small Floor Wash ZESRPFW- · 1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-WARNING Remote Class II electronic power supply will power

1.57"

2.48

"

2.48"

0.157"

1.732"

Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-

WARNINGRemote Class II electronic power supply will power the fixture with low voltage. DO NOT CONNECT FIXTURE WITH LINE VOLTAGE. FAILURE TO COMPLY WILL RESULT IN VOID OF WARRANTY. See Fixture Connection (page 2) for more information.To ensure a maximum efficient use of the product, read the instructions before proceeding installment.

This fixture must be installed by a licensed and qualified electrician. The installer must comply with NEC and local building codes when installing the fixture

Electrical current can cause painful shock, serious injury, or even death. Make sure you turn off the power supply, ground fixture(s), and make sure all electrical connections are correct and secured tightly

For use in IP66 installations.

Keep the label of the original packaging if any eventual future claims are needed

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 1 of 5

0.44 lbs

24VDC

+95°C

-13°F

3'

Table of Contents

Fixture Connection Fixture Installation Distribution of Light Maintenance Support

Pg.2Pg.3Pg.4Pg.5Pg.6

ZEDGE SmallZESRP-

COD. 2DI2CS00

Page 2: ZEDGE Small Floor Wash ZESRPFW- · 1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-WARNING Remote Class II electronic power supply will power

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 2 of 5

24VDC

USE 18 AWG 2C SHIELDED WIRE

Zedge Small Sleeve1E3166

Fixture Connection

Fixture will be connected to 24 VDC output cable running through the fixture's installed sleeve or cavity with water tight connectors that are approved by code powered from a remote driver. DO NOT CONNECT THE FIXTURE TO LINE VOLTAGE. CONNECTING THE FIXTURE TO LINE VOLTAGE WILL DAMAGE THE FIXTURE AND VOID THE WARRANTY. Installer will be sure to only use 18 AWG shielded wiring to connect to the fixture. Be sure to connect the wires correctly on the connector and tightly securing it before connecting fixture. Provided below are the specs for fixture's driving power and dimming capabilities.

Power and Dimming Spec Chart

Power Supplies Type/Dimming TypeMax FixturesPer Driver Wattage

Input Voltage/Output Voltage

DELV-96-1-24-D

Electronic Low Voltage/Reverse Phase

40W

120-277VAC/24VDC

DELV-60-1-24-D 60W

DELV-40-1-24-D

96W

96W

DELX-90-1-24-1C-PWMElectronic PWM in NEMA3R Enclosure 90W

DELX-60-1-24-1C-PWM 60W

5

8

13

8

13

13

DMLV-120-1-24-DDMLV-60-1-24-DDMLV-40-1-24-D

DMLV-192-2-24-D

D010-96-1-24-D

DELX-270-3-24-3C-PWM

Electronic PWM in NEMA3R Enclosure

DELX-180-2-24-2C-PWM 26

39

Magnetic Low Voltage/Forward Phase

Electronic/0-10V

581326

40W60W96W

192W/2x96W

270W

180W

two rows of 13ea

120VAC/24VDC

120-277VAC/24VDC

120-277VAC/24VDC

DO NOT CONNECT FIXTURE TO MAIN VOLTAGE

Dimensions

2.50”W X 9.37”L x 1.89”D

3.00”W X 9.80”L x 3.00”D

10”W X 10”L 4”D

12”W X 12”L 4”D

2.67”W X 9.66”L 1.53”D

3.00”W X 9.80”L x 3.00”D2.25”W X 6.55”L x 2.55”D

2.00”W X 5.06”L x 2.14”D

12”W X 12”L 4”D

10”W X 10”L 4”D

2.50”W X 9.37”L x 1.89"D

4.06”W X 11.02”L x 2.20"D

DEDD-200-2-24-4C-DMXElectronic DMX in NEMA3R Enclosure 200W/ 2x100W

DEDD-100-1-24-4C-DMX 100W13

26two rows of 13ea

DEDD-200-2-24-4C-DALI

Electronic DALI in NEMA3R Enclosure

DEDD-100-1-24-4C-DALI 13

26two rows of 13ea 200W/ 2x100W

100W

120-277VAC/24VDC

120-277VAC/24VDC

10”W X 10”L 4”D

10”W X 10”L 4”D

12”W X 12”L 4”D

12”W X 12”L 4”D

Page 3: ZEDGE Small Floor Wash ZESRPFW- · 1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-WARNING Remote Class II electronic power supply will power

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 3 of 5

Zedge Small Sleeve1E3166

1

2 Top View

Fixture Installation

1) Once the fixture's connection between the fixture and the driverhave been properly connected and tightly secured, locate thespring loaded mounting clip and press one side of the clip towardsthe mounted sleeve opening as you slide the whole fixture into themounted sleeve. The spring will compress together as the fixture ispushed through the insert.

2) As the fixture slides all the way into the sleeve insert, the springclip will open up and secure the fixture into its mounting position.The fixture will sit semi-flush within the sleeve as the face plate offixture sits flat on the mounted surface.

Zedge face plate

Page 4: ZEDGE Small Floor Wash ZESRPFW- · 1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-WARNING Remote Class II electronic power supply will power

Distribution of Light

FLOOR WASHER

BI-EMISSION

LOUVER

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 4 of 4Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 -

(714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 4 of 4

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 4 of 4Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 -

(714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 4 of 4

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 4 of 5

Page 5: ZEDGE Small Floor Wash ZESRPFW- · 1.57" 2.48" 2.48" 0.157" 1.732" Floor Wash ZESRPFW-Louver ZESRPLV-Bi-Emission ZESRPBE-WARNING Remote Class II electronic power supply will power

Targetti USA - A Targetti Group Company - 750-A W. 17th. St. Costa Mesa, CA 92627 - (714) 513-1991 Email: [email protected] - www.targetti.us - 09/2017 - Page 5 of 5

Support

Any questions, problems, or comments you have please feel free to contact our Customer Service department

during our business hours Monday-Friday 8am-5pm via: Email: [email protected]

Phone: (714) 513-1991

Visit our website: http://www.targetti.us

Maintenance

This fixture was designed and manufactured for a durable, long lasting use with minimum care. To ensure the

maximum lifespan of this product, we encourage our customer to provide a quality visual inspection of the fixture

every six months.If there are any visible sign of issues (i.e moisture or dust)

during the inspection, please clean any of the dust or moisture with a soft cloth and check to make sure that any of the fixtures are still operating normally. If there are any issues regarding the fixture please contact us as we will

assist the situation at hand.