2
www.genorayamerica.com Genoray Makes the Invisible Visible Built on vast experience and superior technology, Genoray is a leading X-ray system manufacturer. ZEN-7000 The “Performance Standard” in Digital Imaging Simple, Stylish, Performance C-Arm

Upload: others

Post on 05-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ZEN-7000 The “Performance Standard”capitalxray.com/files/products/ZEN-7000_Brochure.pdf · ZEN-7000 FUNCTION Orbital Movement Wig-wag Movement Vertical Movement Horizontal Movement

www.genorayamerica.com

Genoray Makes the Invisible Visible Built on vast experience and superior technology, Genoray is a leading X-ray system manufacturer.

ZEN-7000

The “Performance Standard”

in Digital Imaging

Simple, Stylish,

Performance C-Arm

Page 2: ZEN-7000 The “Performance Standard”capitalxray.com/files/products/ZEN-7000_Brochure.pdf · ZEN-7000 FUNCTION Orbital Movement Wig-wag Movement Vertical Movement Horizontal Movement

- Rotating anode

- Heavy-weight performance: 120kV / 20mA

More Powerful Than Ever

Real Time Display Surgery Assistant Sharp Contrast

Performance C-Arm

Discover a new level of POWER and CLARITY

Convenient

- Full-size touch screen

- Easy to use operational panel

kV, mA, collimator, image control, etc.

- Virtual collimation

- Tri-mode 9” I.I.

- 1K x 1K CCD technology

- Standard DICOM 3.0

Features

Light, yet powerful & reliable C-Arm!

Quality & Value in ONE

Technical Speci!cations & Dimensions

Genoray Makes the Invisible Visible

All measurements of diagram in inches

Genoray America Inc.

1073 N. Batavia St. Orange, CA 92867 USA

TEL : 855-GENORAY FAX : 714-453-9661

[email protected] 20

11

Ge

no

ray

Am

eri

ca In

c.

©

26.77

47.64

71.93 - 79.80

92.40 - 100.28

19.69

30.71

30

.71

43

.50

- 6

1.2

0

17

.72

71

.77

- 8

9.4

9

ZEN-7000

FUNCTION

Orbital Movement

Wig-wag Movement

Vertical Movement

Horizontal Movement

Depth

Free Space

SID

Rotation

135˚ (45˚ overcast)

± 12.5˚

15.75in (40cm)

7.87in (20cm)

26.77in (68cm)

30.71in (78cm)

39.37in (100cm)

± 190˚

GENERATOR

Inverter Frequency

Power

kV Range on Fluoroscopy

mA Range on Fluoroscopy

kV Range on Radiography

Max Value of Radiography Current

mAs

Snap Shot

40 kHz

5 kW

40-120kV

0.1~7mA / 20mA

40-120kV

70 mA

0.4-100mAs

10-25mA

TUBE

Anode Heat Capacity (HU)

Small Focus

Large Focus

Anode Type

Collimation

Laser Pointer

300,000

0.3 mm

0.6 mm

Rotating

Irıs & Blades

Yes (Optional)

9"

19" (B/W Medical Grade)

CCD Camera

(1k x 1k pixel)

DIGITAL MEMORY,

IMAGE PROCESSINGZENIS system / Window 7

DIGITAL MEMORY, IMAGE PROCESSING

Image Capacity

LIH, Digital Recording

Dual Monitor Display

Edge Enhancement

A/D Conversion

Frames Per Sec

DICOM 3.0

Cine Loop Recording

Minimum Dose Pulse Mode

100,000

Yes

Yes

Yes

14 bit

30 / 15 fps

Yes

Yes

Yes

I.I.

Monitor

Camera Type

Safety Assured

- Automatic shut o" to prevent over-heating

- Counter-balanced

- Emergency switch for manual shut o"

*The specifica"ons above can be changed to improve quality.