zoeller x292
TRANSCRIPT
7/22/2019 Zoeller x292
http://slidepdf.com/reader/full/zoeller-x292 1/2
X292 - X293 - X294 - X295
(For Pump Prefi x Identi fi cation see News & Views 0052)
HIGH HEAD
EXPLOSION PROOF SUBMERSIBLE
SEWAGEOR DEWATERING PUMP
COMPARE THESE FEATURES• FM listed motor for Class 1, Division 1, Group C & D
environments.
• Non-clogging vortex impeller design bronze class88-8-0-4.
• Stainless steel rotor shaft.• Durable cast construction. Cast iron cover, motor
adapter and pump housing. No sheet metal parts torust or corrode. All cast iron class 30, 30000# tensilestrength.
• Stainless steel screws and handle.• 20 ft. UL Listed 5-wire (1 PH) or 8-wire (3 PH) neoprene
cord. Extra cords lengths available in 25'-35'-50' lengthonly. Sensor leads & power leads in one cord for easyinstallation.
• 1¼" NPT threaded conduit connection for protectingcords in those extra heavy duty applications.
• Moisture sensors prewired in motor housing (requiresindicator in panel).
• Zoeller custom designed panels with intrinsically saferelays and moisture indicator are required.
• 3 phase models available.• Motor - 60 Hz, 3450 RPM, oil-filled, hermeticallysealed, automatic reset thermal overload protected(3 phase requires circuit in control panel).
• Maximum temperature for sewage or dewatering104°F (40°C).
• Shaft Seal - Stainless steel wetted parts, carbon &ceramic rotary face seal.
• Upper ball bearing and lower ball bearing running inbath of oil.
• Buna-n square ring seals.• All models pass 2" spherical solids.
• Major width 135
/16". Height 22".• Available in nonautomatic units only.• When ordering specify 2" or 3" NPT female flanged
vertical discharge.• 100% computerized testing and 100% tested sub-
merged in water.• Corrosion resistant powder coated epoxy finish.
Note: The sizing of sewage systems normally requires vari-
able level float(s) controls and properly sized basins to achieve
required pumping cycles.
SECTION: 2.40.040
FM1702
0206
Supersede
0305
*See back page For FM Listing.
Product information presentedhere reflects conditions at timeof publication. Consult factoryregarding discrepancies orinconsistencies. MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
visit our web site:
www.zoeller.com
© Copyright 2006 Zoeller Co. All rights reserved.
Nonautomatic Models for
intrinsically safe variable
level systems
Not for use in acidic, methanol, or ethyl acetate atmospheres.
Standard 3600 & 3615
7/22/2019 Zoeller x292
http://slidepdf.com/reader/full/zoeller-x292 2/2
6 1/2
8 3/4
21 1/2
6
4 9/16
4 9/16
22
CHECK VALVE
2" NPT
OR
3" NPT
AVAILABLE1 1/4" - 11 1/2 NPT
RESERVE POWERED DESIGNFor unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
Standard all models - 20 ft. cord - ½ H.P.
292 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
NX292 115 1 Non 15.0 1 & 3 1 & 3 or 2 Y
Standard all models - 20 ft. cord - 1 H.P.
293 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
EX293 230 1 Non 10.2 1 & 3 1 & 3 or 2 Y
IX293 200 1 Non 12.0 1 & 3 1 & 3 or 2 Y
FX293 230 3 Non 7.6 1 & 3 1 & 3 Y
JX293 200 3 Non 8.2 1 & 3 1 & 3 Y
GX293 460 3 Non 4.0 1 & 3 1 & 3 Y
BAX293 575 3 Non 3.3 1 & 3 1 & 3 Y
Standard all models - 20 ft. cord - 1½ H.P.
294 MODELS Control Selection Listing
Single Seal Volts - Ph Mode Amps Simplex Duplex FM
EX294 230 1 Non 13.7 1 & 3 1 & 3 or 2 Y
IX294 200 1 Non 17.8 1 & 3 1 & 3 or 2 Y
FX294 230 3 Non 9.5 1 & 3 1 & 3 Y
JX294 200 3 Non 10.8 1 & 3 1 & 3 Y
GX294 460 3 Non 4.8 1 & 3 1 & 3 Y
BAX294 575 3 Non 3.8 1 & 3 1 & 3 Y
Standard all models - 20 ft. cord - 2 H.P.
295 MODELS Control Selection ListingSingle Seal Volts - Ph Mode Amps Simplex Duplex FM
EX295 230 1 Non 17.1 1 & 3 1 & 3 or 2 Y
IX295 200 1 Non 20.5 1 & 3 1 & 3 or 2 Y
FX295 230 3 Non 12.2 1 & 3 1 & 3 Y
JX295 200 3 Non 14.3 1 & 3 1 & 3 Y
GX295 460 3 Non 6.1 1 & 3 1 & 3 Y
BAX295 575 3 Non 4.9 1 & 3 1 & 3 Y
SELECTION GUIDE
1. See FM1705 for correct intrinsically safe simplex or duplex
panel.2. Mechanical alternator “M-Pak” 10-0076 or 10-0077 (See
FM1783).
3. Variable level control switch used as a control activator.
Quantity required dependent upon panel selection.
Single Seal
Weight - 125 lbs.
© Copyright 2006 Zoeller Co. All rights reserved.
All installation of controls, protection devices and wiring should be done by a qualified licensed
electrician. All electrical and safety codes should be followed including the most recent NationalElectric Code (NEC) and the Occupational Safety and Health Act (OSHA).
For information on additional Zoeller products refer to catalog on Duplex and Simplex controls, FM1705;
Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487; and Rail Systems, FM0787.
Model 293 should
not be subjected to less than 15
feet TDH.
SK1914
PUMP PERFORMANCE CURVE
MODEL X292/X293/X294/X295
130
480
T O T A L D Y N A M I C
H E A
D
FLOW PER MINUTE
GALLONS
LITERS0
0
10
25
4
15
80
10 20
160
30 40
30
6 20
825
10
35
12 40
240
50 60
320
70 80 110
400
90 100 120
X293
70
50
1445
16
55
18 60
20 65
M E T E R S
F E E T
22
80
X295
800640
170
560
150140 160
X292
X294
720
190180 200 210 220
75
24
9.130
40
60
70
Shut-off Head:
50
18.3
21.3
12.2
15.2
Feet
25
10
15
20
4.6
6.1
7.6
Meters
5 1.5
3.0
75 ft.(22.9m)
Liters
--
50 ft.(15.2m)
--
--
363
--
182
310
409
447
--
8221256
42 ft.(12.8m)
-- --
--
10
--
--
38
--
--
--
48
--
91
108
75
344
409
284
140
Gal.
124
530
Liters
469
108
118
96
--
Gal.
--
140121 458
356
62 ft.(18.9m)
--
220
13
--
94
58
5949
23
115
89
742
Liters
515
568
625
685
150
165
136
196
Gal.
181
168
184
154
214
Gal.
199
530
223
87
435
337
636
696
583
Liters
810
753
MODEL X295X293X292 X294
009919