Page 1: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

Power Systems Virtualization 4Q 2009 Update

IBM Power Systems

Vess Natchev, [email protected]

IBM Lab Services, Rochester

Page 2: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

2

Agenda

Virtualization with PowerVM: overview IBM i and Virtual I/O Server (VIOS) I/O virtualization Interfaces: HMC and Integrated Virtualization Manager (IVM) HMC enhancements IVM support for IBM i logical partitions (LPARs) N_Port ID Virtualization for IBM i Redundant VIOS support with client-side MPIO End-to-end device mapping Active Memory Sharing (AMS) PowerVM Lx86 Systems Planning Tool (SPT) IBM Systems Director and VMControl: advanced virtualization management Let IBM Lab Services help with virtualization!

Page 3: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

3

IBM develops hypervisor that would become VM on the mainframe

IBM announces first machines to do physical partitioning

IBM announces LPAR on the mainframe

IBM announces LPAR on POWER™

19671967 19731973 19871987

IBM intro’s POWER Hypervisor™ for System p™ and System i™

IBM announces PowerVM

200720072004200419991999 20082008

IBM announces POWER6™, the first UNIX® servers with Live Partition Mobility

IBM’s History of Virtualization Leadership

A 40 year tradition continues with PowerVM™

Page 4: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

4

What Is PowerVM?

Micro-Partitioning™

Subsystems

Workload Partitions

Live Application Mobility

PowerVM Editions features

Micro-Partitioning

Virtual I/O Server

Integrated Virtualization Manager

Live Partition Mobility

Lx86 (formerly System p AVE)

Logical Partitioning

Hardware and software that delivers industry-leading virtualization on IBM POWER processor-based servers for IBM i, UNIX and Linux clients

Page 5: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

5

PowerVM Editions

Unified virtualization offerings for IBM i, AIX and Linux

Provides advanced virtualization capability for Power servers and blades

PowerVM Standard Edition is used most often for IBM i workloads

Live Partition Mobility is not yet supported for IBM i

Express Standard Enterprise

Maximum LPARs 1+2 / Server 10 / Core 10 / Core

Management IVM IVM, HMC IVM, HMC

Virtual I/O Server

Lx86

Multiple Shared Processor Pools

Live Partition Mobility

Active Memory Sharing

PowerVM Editions

More information: http://www.ibm.com/systems/power/software/virtualization/index.html

Page 6: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

6

IBM i I/O Virtualization Can Improve Service

Respond quickly and flexibly to business opportunities and customer demands; align physical and IT assets to the business to enable rapid, agile response to changing business circumstances

Power Systems support dedicated I/O – I/O resources assigned to partitions– Adapters can be moved between partitions

IBM i supports I/O virtualization– IBM i can host I/O for i 6.1, AIX, & Linux partitions– Plus iSCSI-attached VMware and Windows servers

√ Reduce costs while improving IT infrastructure flexibility

Power Hypervisor

VIOS

Power Hypervisor

IBM i 6.1 hosting of IBM i 6.1 partitions requires POWER6 processor-based servers

Page 7: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

7

VIOS I/O Virtualization Can Improve Service

Respond quickly and flexibly to business opportunities and customer demands; align physical and IT assets to the business to enable rapid, agile response to changing business circumstances

Power Systems support dedicated I/O – I/O resources assigned to partitions– Adapters can be moved between partitions

PowerVM adds I/O virtualization– Virtual I/O Server (VIOS) enables sharing

of I/O resources among partitions– NPIV support simplifies SAN management (new!)– Multiple VIOS partitions provide redundancy (new!)

√ Reduce costs while improving IT infrastructure flexibility

Power Hypervisor

VIOS

Power Hypervisor

* Support planned for IBM i

VIOS hosting of IBM i 6.1 partitions requires POWER6 processor-based servers

Page 8: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

8

When Is PowerVM Required? Try This Quiz!

Scenario I: – 8203-E4A 2-way– 1 IBM i host partition and 1 IBM i virtual client partition– Dedicated processors– Is PowerVM required?

Scenario II:– 8203-E4A 2-way– 3 IBM i partitions– Is PowerVM required?

Scenario III:– 8203-E4A 2-way– 1 VIOS host partition and 1 IBM i client partition– Dedicated processors– Is PowerVM required?

Page 9: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

9

When Is PowerVM Required? Try This Quiz!

Scenario I: – 8203-E4A 2-way– 1 IBM i host partition and 1 IBM i virtual client partition– Dedicated processors

– Is PowerVM required? NO

Scenario II:– 8203-E4A 2-way– 3 IBM i partitions

– Is PowerVM required? YES

Scenario III:– 8203-E4A 2-way– 1 VIOS host partition and 1 IBM i client partition– Dedicated processors

– Is PowerVM required? YES

Page 10: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

10

Virtualization Interfaces: HMC and IVM

Hardware Management Console

– Browser-based console for server and virtualization management

– Used for Power Servers

– Create VIOS, IBM i LPARs

– Provision virtual storage, DVD, tape, networking

– Configure NPIV

Integrated Virtualization Manager

– Browser-based management tool for LPAR and virtualization management

– Runs in VIOS LPAR

– Can be used for Power 520/550, required for Power blades

– Create IBM i LPARs

– Provision virtual storage, DVD, tape, networking

– Configure NPIV

Page 11: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

11

VIOS Configuration: HMC System1) Assign volumes to FC adapters in VIOS using WWPNs2) In HMC: Server->Configuration->Virtual Resources->Virtual Storage Management

No need to use VIOS command line Assign volume to correct IBM i LPAR Volume then becomes available to IBM i as DDxx

Page 12: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

12

VIOS Configuration: IVM System1) Assign volumes to FC adapters in VIOS using WWPNs2) In IVM: View/Modify Virtual Storage Physical Volumes

No need to use VIOS command line Assign volume to correct IBM i LPAR Volume then becomes available to IBM i as DDxx

Page 13: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

13

IVM support for IBM i LPARs

PowerVM Integrated Virtualization Manager provides an easier to use, lower cost of entry virtualization solution

– Supports virtualization without an HMC – Provided with PowerVM Express, Standard, and Enterprise Editions

i 6.1 partitions are supported with IVM on BladeCenter JS12, JS22, JS23, JS43 and Power 520 (8203) and 550 (8204) systems

– VIOS partition owns disk, DVD, tape and Ethernet hardware resources– IBM i is a purely virtual partition

PowerVM Express Edition available for i clients– Entry solution supporting up to 3 partitions – VIOS plus 2 others

Power Hypervisor

VIOSWith IVM

Power Hypervisor

VIOS With IVM

Page 14: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

14

Use IVM, HMC or Either? Try This Quiz! Scenario I:

– 8204-E8A– 1 IBM i host partition, 4 IBM i client partitions, no other partitions– IVM, HMC, or either?

Scenario II: – 7778-23X (JS23 Power blade)– 1 VIOS host partition, 1 IBM i client partition, 2 Linux client partitions– IVM, HMC, or either?

Scenario III:– 8203-E4A– 1 VIOS host partition, 1 IBM i client partition, 1 AIX client partition– IBM i client partition requires access to physical tape adapter– IVM, HMC, or either?

Scenario IV:– 8204-E8A– 1 VIOS host partition, 2 IBM i client partitions, 2 AIX client partitions– IVM, HMC, or either?

Scenario V:– 9117-MMA– 1 VIOS host partition, 2 IBM i client partition, 3 AIX client partitions, 1 Linux partition client partitions– IVM, HMC, or either?

Page 15: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

15

Use IVM, HMC or Either? Try This Quiz! Scenario I:

– 8204-E8A– 1 IBM i host partition, 4 IBM i client partitions, no other partitions– IVM, HMC, or either? HMC

Scenario II: – 7778-23X (JS23 Power blade)– 1 VIOS host partition, 1 IBM i client partition, 2 Linux client partitions– IVM, HMC, or either? IVM

Scenario III:– 8203-E4A– 1 VIOS host partition, 1 IBM i client partition, 1 AIX client partition– IBM i client partition requires access to physical tape adapter– IVM, HMC, or either? HMC

Scenario IV:– 8204-E8A– 1 VIOS host partition, 2 IBM i client partitions, 2 AIX client partitions– IVM, HMC, or either? Either

Scenario V:– 9117-MMA– 1 VIOS host partition, 2 IBM i client partition, 3 AIX client partitions, 1 Linux partition client partitions– IVM, HMC, or either? HMC

Page 16: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

16

NPIV Support for DS8000 and FC Tape Libraries

EMC

IBM i

VIOS

FC HBAs

DS5000

generic scsi disk

generic scsi disk

SVC

VIOS

FC HBAs

SAN

IBM i

FCPVIOS

FC HBAs

DS8000

VIOS

FC HBAs

SAN

DS8000

SCSI

Multiple storage subsystems supported* Storage assigned to VIOS first, then virtualized

to IBM i Can be configured with HMC or IVM

DS8000 and certain FC tape libraries supported Storage mapped directly to Virtual FC adapter in

IBM i, which uses N_Port on FC adapter in VIOS Uses VIOS in passthrough mode

* See section 7 of the IBM i Virtualization and Open Storage Readme: http://www.ibm.com/systems/i/os

VSCSI NPIV

Page 17: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

17

NPIV Benefits for IBM i

Sharing dual-port 8Gb FC adapters among multiple partitions– One port from 2 separate adapters can be shared to same client partition, allowing for

adapter redundancy

Support for FC tape libraries in VIOS environment– Tape library recognized with device-specific machine-type and model (MTM) in IBM i and

all library functions supported

Support for DS8000 storage– Volumes recognized with device-specific MTM and as protected or unprotected

Support for DS8000 Copy Services with PowerHA in a VIOS environment– Similar to natively attached DS8000 today

Page 18: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

18

Configure Disk and Tape Virtualization with NPIV

EMC

IBM i

FCPVIOS

FC HBAs

DS8000

VIOS

FC HBAs

SAN

DS8000

1

Step 1: configure virtual and physical FC adapters

Step 2: configure SAN fabric and storage/tape

2

Page 19: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

19

Use HMC to create Virtual FC (VFC) server and client adapters

1VIOS IBM i

Configure Disk and Tape Virtualization with NPIV

Page 20: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

20

1

Use HMC to assign IBM i LPAR and VFC adapter pair to physical FC port

Configure Disk and Tape Virtualization with NPIV

Page 21: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

21

2

Use DS8000 or tape library UI and Redbook to assign LUNs or tape drives to the WWPN from the VFC client adapter in i LPAR

Configure Disk and Tape Virtualization with NPIV

Page 22: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

22

Redundant VIOS Support with Client-side MPIO

Redundant VIOS Support– Enables IBM i 6.1 partitions to utilize redundant VIOS partitions with 1 set of

storage LUNs– Improves availability of virtualized environment– Can assign two paging VIOS partitions to a shared memory pool to provide

redundant access to the paging devices.– Available on Power servers only, not on Power blades

Power Hypervisor

VIOS VIOS

Page 23: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

23

Host group definition on SAN

Host groups are used to share access to the same logical drives between VIOS partitions

And repeat for the second VIOS host

Page 24: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

24

Page 25: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

25

End-to-end Device Mapping

In HMC: Server->Partitions->VIOS LPAR->Hardware Information-> Virtual I/O Adapters->SCSI

Allows direct mapping of LUNs attached to VIOS (hdiskX) to disk units in IBM i (DD0xx) Facilitates configuration changes and troubleshooting Requires VIOS 2.1.2 or later

Page 26: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

26

Innovative solution for more efficient utilization of memory resources

Available with PowerVM Enterprise Edition– No additional cost

System requirements:– IBM Power Systems server or blade with POWER6 processors– Virtual I/O Server (VIOS) 2.1.1– Firmware level: eFW 3.4.2– HMC v7.342

Active memory Sharing is optionally configurable on a partition basis– Shared Memory Partitions must be defined in shared processor mode

– Shared Memory Partitions must be “pure virtual”, ie all I/O devices are accessed via the VIOS

Virtual SCSI Client Adapters

Virtual Ethernet Adapters

Virtual Serial Server Adapters

Operating systems supported:– AIX 6.1 TL3– IBM i 6.1 plus PTFs– SUSE Linux Enterprise Server 11

PowerVM active memory sharing (AMS)

0

5

10

15#10

#9

#8

#7

#6

#5

#4

#3

#2

#1

Mem

ory

Usa

ge

(GB

)

TimeWorkloads

White paper on AMS: http://www.ibm.com/systems/power/software/virtualization/whitepapers/ams.html

Page 27: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

27

IVM example: working with AMS – define a pool

Page 28: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

28

IVM example: working with AMS – pool definition

Page 29: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

29

IVM example: working with AMS – partition properties

Page 30: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

30

HMC example: working with AMS – define a pool

Select the System i to work with -> Tasks -> Virtual Resources -> Configuration -> Shared memory pool management

Page 31: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

31

HMC example: working with AMS – define a pool

Page 32: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

32

HMC example: working with AMS – partition properties

Page 33: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

33

Consolidate Linux Servers

PowerVM Lx86 – Run x86 Linux applications on Power Systems

√ Simplifies migration of Linux on x86 applications to realize the energy and administration savings of consolidation

Power Systems Platform

Supported Linux OS

PowerVM Lx86

x86 Linux OS

App

AIX OS

AIX OSApplication

POWER Linux OS

Application

PowerVM

Page 34: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

34

PowerVM System Planning Tool

Simplifies the planning and installation of Power servers with PowerVM– Browser-based application that helps you design logical partitioned systems– Integrated with the Workload Estimator – Integrated with IBM ordering system

Download: www.ibm.com/systems/support/tools/systemplanningtool

Page 35: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

35

Discover servers

Monitor and report system health

Optimize and update servers

Integrate with enterprise service management

Providing a foundation for enterprise platform management

Managed Infrastructure

Page 36: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

36

Systems Director VMControl

Plug-in for IBM Systems Director– Express, Standard, Enterprise Editions

Simplifies virtualization management

Entry into cloud computing for Power Systems

http://www.ibm.com/systems/management/director/plugins/vmcontrol/index.html

Page 37: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

37

Systems Director VMControl

Virtual image (appliance) management and deployment

System pools (clouds)

Storage integration

Page 38: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

38

IBM Systems Director VMControl 2.1Image Manager Overview

Discover existing image repositories and import external, standards-based images into your repositories as virtual appliances.

Capture a running virtual server that is configured just the way you want, complete with guest operating system, running applications, and virtual server definition. When you capture the virtual server, a virtual appliance is created in one of your image repositories.

Import virtual appliance packages that exist in the Open Virtualization Format (OVF) from the Internet or other external sources. After the virtual appliance packages are imported, you can deploy them within your data center.

Deploy virtual appliances quickly to create new virtual servers that meet the demands of your ever-changing business needs.

Systems Director VMControl Image Manager supports deploying virtual appliances to the following platforms:

– PowerVM virtual appliances on IBM® Power Systems® servers (POWER5™ and POWER6™) that are managed by Hardware Management Console or Integrated Virtualization Manager

– Linux® virtual appliances on System z® systems running on the z/VM® hypervisor

meta-data

SW

OS

Virtual Appliance

Page 39: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

39

Power Systems Pools with VMControl 2.2 Simplifying the management of Power Systems

– Integration with the IBM Systems Director dashboard

– Dynamic Virtual Server Placement– Simplified Image Capture, Deploy and Customize– Virtual Server Relocation/Mobility– Workload Resilience

Support for POWER5 and POWER6 Systems– New systems or available capacity from existing

systems– IVM and HMC managed systems

Support for AIX NIM as an image repository for both single systems and Power System Pools.– Discovery of existing mksysb images– Repository for image capture – Network install as part of deployment

Dynamic allocation of SAN storage– VIOS managed volume groups– Shared SAN storage pools

Power System Pool

Image Repository

IBM Systems Director VMControl

AIX NIM

SAN Storage

Mobility

Page 40: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

4040

04/20/23

Workload (Virtual Server) Resilience within a System Pool

Relocate Virtual Servers between Hosts within the Pool- Determine best host placement within the pool- Supports single virtual servers and host evacuation

Move virtual servers away from a failing host system.- Automate relocation and placement of virtual servers in response to

predicted host system failures with no disruption.

Restart virtual servers when a host system fails.- Automate remote restart and placement of virtual servers in response

to host system failures with minimal disruption.- From a checkpoint in the future.

Resilience policy associated with the workload- Provide workload resilience – yes/no- Enables host system monitoring for failures and predictive failures- Automates recovery action based on desire level of automation

Automation policy associated with the workload- Automate = Advise / Automate- Advise – VMControl recommends actions and requires confirmation- Automate – VMControl automates actions

View In Animation Mode

System Pool (Ensemble)

Page 41: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

41

IBM Systems Lab Services Virtualization Program

What is it?– Free presales technical assistance from Lab Services– Help with virtualization solutions:

Open storage (such as DS5100 and DS5300)Power bladesIBM Systems Director VMControlOther PowerVM technologies

– Design solution, hold Q&A session with client, verify hardware configuration– Does not cover implementation

Who can use it?– IBMers, Business Partners, clients

How do I use it?– Contact Lab Services for nomination form – [email protected]– Send in form– Participate in assessment call with Virtualization Program team– Work with dedicated Lab Services technical resource to design solution

before the sale

Page 42: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

42

Service Vouchers

• Getting-started implementation services • 8 hours of services with each voucher• Any additional services are billable• http://www.ibm.com/systems/i/hardware/editions/services.html

Page 43: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

43

Resources

IBM i Virtualization and Open Storage Read-me First: http://www.ibm.com/systems/i/os IBM i and storage performance information:

http://www.ibm.com/systems/i/advantages/perfmgmt/resource.html Service vouchers: http://www.ibm.com/systems/i/hardware/editions/services.html

Page 44: © 2009 IBM Corporation Power Systems Virtualization 4Q 2009 Update IBM Power Systems Vess Natchev, vess@us.ibm.com IBM Lab Services, Rochester

© 2009 IBM Corporation

IBM Power Systems

44

8 IBM Corporation 1994-2007. All rights reserved.References in this document to IBM products or services do not imply that IBM intends to make them available in every country.

Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web at http://www.ibm.com/legal/copytrade.shtml.

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce.ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office.UNIX is a registered trademark of The Open Group in the United States and other countries.Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.

Information is provided "AS IS" without warranty of any kind.

The customer examples described are presented as illustrations of how those customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics may vary by customer.

Information concerning non-IBM products was obtained from a supplier of these products, published announcement material, or other publicly available sources and does not constitute an endorsement of such products by IBM. Sources for non-IBM list prices and performance numbers are taken from publicly available information, including vendor announcements and vendor worldwide homepages. IBM has not tested these products and cannot confirm the accuracy of performance, capability, or any other claims related to non-IBM products. Questions on the capability of non-IBM products should be addressed to the supplier of those products.

All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance, function or delivery schedules with respect to any future products. Such commitments are only made in IBM product announcements. The information is presented here to communicate IBM's current investment and development activities as a good faith effort to help with our customers' future planning.

Performance is based on measurements and projections using standard IBM benchmarks in a controlled environment. The actual throughput or performance that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvements equivalent to the ratios stated here.

Prices are suggested U.S. list prices and are subject to change without notice. Starting price may not include a hard drive, operating system or other features. Contact your IBM representative or Business Partner for the most current pricing in your geography.

Photographs shown may be engineering prototypes. Changes may be incorporated in production models.

Trademarks and Disclaimers