© 2010 mindray confidential bc-5300 small & big. a compact 5-diff solution small size big...
TRANSCRIPT
© 2010 Mindray Confidential
BC-5300 Small & Big
A compact 5-diff solution
Small size Big content
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
∑
WBC
Total No
Lymphocytes (#,%)
Monocytes (#,%)
Neutrophils (#,%)
Eosinophils (#,%)
Basophils (#,%)
DIFF WBC/BASO
RUO
Atypical Lymphocytes (#,%)
Large Immature Cell (#,%)
PLT
Total No
MPV
PCT
PDW – CV
RBC
Total No
HGB
HCT
MCV
MCH
MCHC
RDW – CV,SD
Complete CBC+5DIFF result
23+4Parameters
5 Reagents
2 YEARSHELF LIFE
Original quality control and calibratorBC-5D and SC-CAL PLUS
Participation in online QC programCBC-Monitor
QC & Calibrator
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
20 ul sample volumewhole blood & capillary blood
60 tests/hr throughputreport ready within 1min
Lateral needle apertureavoid sample blockage
0 daily maintenanceautomatic shutdown
Economical running
Reagent Consumption
Save every drop of reagent
Low reagent consumption per test
Low dead volume per bottle
Less maintenance
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
Neu%
y = 0.921x + 5.7703R2 = 0.9378
0
20
40
60
80
100
120
0 20 40 60 80 100 120
Manual differential count(%)
BC
-53
00
(%)
Lym%
y = 0.9219x + 0.8691R2 = 0.9351
0
20
40
60
80
100
0 20 40 60 80 100
Manual differential count(%)B
C-5
30
0(%
)
Mon%
y = 0.7313x + 1.2876R2 = 0.563
0
5
10
15
20
25
0 5 10 15 20 25 30
Manual differential count(%)
BC
-53
00
(%)
Eos%
y = 0.9167x + 0.53R2 = 0.8279
0
5
10
15
20
25
30
35
0 5 10 15 20 25 30
Manual differential count(%)
BC
-53
00
(%)
Bas%
y = 0.6528x + 0.6109R2 = 0.4553
0
2
4
6
8
10
12
14
16
0 5 10 15 20
Manual differential count(%)
BC
-53
00
(%)
Correlation with microscopic counting
WBC
y = 1.0272x - 0.0566R2 = 0.9975
0
5
10
15
20
25
30
35
40
0 10 20 30 40
LH-750
BC
53
00
Neu%
y = 0.9514x + 3.9162R2 = 0.9862
0
20
40
60
80
100
120
0 20 40 60 80 100 120
LH-750B
C5
30
0
Lym%
y = 1.011x + 0.4576R2 = 0.9904
0
10
20
30
40
50
60
70
80
90
0 20 40 60 80 100
LH-750
BC
53
00
Mon%
y = 0.8019x - 0.7909R2 = 0.8921
0
2
4
6
8
10
12
14
16
18
0 5 10 15 20 25
LH-750
BC
53
00
Eos%
y = 0.9515x + 0.3626R2 = 0.9605
0
5
10
15
20
25
30
0 5 10 15 20 25 30
LH-750
BC
53
00
RBC
y = 0.9856x + 0.0621R2 = 0.9971
0
1
2
3
4
5
6
7
8
0 2 4 6 8
LH-750
BC
53
00
Correlation with Beckman Coulter LH750
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
Integrate-All for Operation, Maintenance & Management
Function
Shortcut
Function
Shortcut
Patient
Information
Patient
Information
Test Results
40000
Test Results
40000
FlagsFlags
GraphicsGraphicsMenuMenu
Integrated information
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
SearchSearch
Workload
Statistics
Workload
Statistics
Patient
Record
Patient
Record
Trend
Screen
Trend
Screen
Easy search and delta-check capability
Special
Insert lab logo or patient photoInsert lab logo or patient photo
Patient information
Patient information
Report HeadlineReport Headline
Customize results:
- parameters- graphics- flags- microscopic
Customize results:
- parameters- graphics- flags- microscopic
Customization on report styles
Complete solution for hematology tests Economical running Accurate and stable performance Friendly user interface Excellent information management Easy maintenance
Auto maintenance set-upAuto maintenance set-up
“Double-click” maintenance“Double-click” maintenance
“Single-click” error removal“Single-click” error removal
Easy and convenient maintenance
Advanced technology
Digital sheath
flow
Chemical dye
Flow cytometry
Laser scatter
DC method for basophils
WBC/BASO Bath
LH Lyse
RBC Lymphocyte Monocyte Basophil Eosinophil Neutrophil
525
nm
HGB
LH lyse shrinks the white blood cells to reduce the size except for basophils;
Digital sheath flow
Good correlation with XE-2100, which uses DC-sheath-flow to test RBC.
After Digital sheath flow
MCV
y = 1. 0813x - 6. 5636R2 = 0. 983
0
20
40
60
80
100
120
140
0 50 100 150XE- 2100
Auto
load
ing/
CBC+
Diff
MCV
y = 1. 0813x - 6. 5636R2 = 0. 983
0
20
40
60
80
100
120
140
0 50 100 150XE- 2100
Auto
load
ing/
CBC+
Diff
RDW- CV
y = 0. 8488x + 0. 5229
R2 = 0. 9534
0
5
10
15
20
25
0 10 20 30XE- 2100
Auto
load
ing/
CBC+
Diff
RDW- CV
y = 0. 8488x + 0. 5229
R2 = 0. 9534
0
5
10
15
20
25
0 10 20 30XE- 2100
Auto
load
ing/
CBC+
Diff
RDW - SD
y = 1. 1217x - 0. 2602
R2 = 0. 9504
0
20
40
60
80
100
120
0 20 40 60 80 100
XE- 2100
Autoloading/CBC+Diff
RDW - SD
y = 1. 1217x - 0. 2602
R2 = 0. 9504
0
20
40
60
80
100
120
0 20 40 60 80 100
XE- 2100
Autoloading/CBC+Diff
Scattergram and flags
DIFFDIFF BASOBASO
LymLym
MonMon NeuNeu
EosEosBosBosEOS
LYM
ALY
MON
LIC
LEFTSHIFT
DIFF
NEU
GHO
Bas
Normal sample
Male, 27 years old, volunteer, healthy
WBC DIFF (n=200)
Neutrophilic band granulocyte
1%
Neutrophil 54%
Lymphocyte 37%
Monocyte 4%
Eosinophil 3.5%
Basophil 0.5%
RBC morph Normal
PLT morph Normal
Microscopic examination results
Microscopic examination results
1 Neutrophil2 Lymphocyte
Normal sample
Neutrophilia
Female, 16 years old, outpatient
Diagnosis: pyrexia (pathogeny to be confirmed)
WBC DIFF (n=200)
Neutrophilic band granulocyte
3%
Neutrophil 81%
Lymphocyte 10%
Monocyte 3.5%
Eosinophil 2%
Basophil 0.5%
RBC morph Normal
PLT morph Normal
Microscopic examination results
Microscopic examination results
1 Neutrophil
1 Neutrophil
1 Neutrophil
1 Neutrophil
Neutrophilia
WBC DIFF (n=200)
Neutrophil 42.5%
Lymphocyte 28 %
Monocyte 4.5 %
Eosinophil 24.5%
Basophil 0.5%
RBC morph Normal
PLT morph Normal
Eosinophila
Female, 25 years old, outpatient
Diagnosis: edema (checking for pathogenesis)
Microscopic examination results
Microscopic examination results
1 Neutrophil
1 Neutrophil
2 Eosinophil
2 Eosinophil
Eosinophila
Immature cell
Male, 34-year-old, outpatient
Diagnosis: adult still
Microscopic examination results
Microscopic examination results
WBC DIFF (n=200)
Myelocytes 1%
Metamyelocytes 2.5%
Neutrophilic band granulocyte
2%
Neutrophil 66.5%
Lymphocyte 22.5%
Monocyte 3.5%
Eosinophil 1.0%
Basophil 1.0%
RBC morph Normal
PLT morph Normal
1 Myelocyte
2 Lymphocyte
Immature cell
Atypical lymphocyte
Female, 2 years old, inpatient
Diagnosis: bronchopneumonia; virus infection confirmed
Microscopic examination results
Microscopic examination results
WBC DIFF (n=200)
Neutrophilic band granulocyte
1%
Neutrophil 14%
Atypical lymphocyte 5 %
Lymphocyte 75.5 %
Monocyte 3%
Eosinophil 0.5 %
Basophil 1.0%
RBC morph Normal
PLT morph Normal
1 Atypical lymphocyte
Atypical lymphocyte
Iron Deficiency Anemia (IDA)
Female, 40 years old, outpatient
She had a CBC routine test after receiving treatment for iron deficiency anemia.
WBC DIFF (n=200)
Neutrophil 65%
Lymphocyte 30%
Monocyte 3.0%
Eosinophil 1.5%
Basophil 0.5%
RBC morph Cells vary in size
PLT morph Normal
Microscopic examination results
Microscopic examination results
1 Neutrophil
Iron Deficiency Anemia (IDA)
Chronic Myelocytic Leukemia (CML)
1 Neutrophil
2 Basophil
Male, 32 years old.
Chief disease: leucocytosis for 2 years
Bone marrow examination result shows a possibility of chronic myelocytic leukemia.
WBC DIFF (n=200)
Myelocytes 1.0%
Metamyelocytes 1.0%
Neutrophilic band granulocyte
2.0%
Neutrophil 46%
Atypical Lymphocyte 1.0%
Lymphocyte 37%
Monocyte 8.0%
Basophil 4.0%
RBC morph Normal
PLT morph Normal
Microscopic examination results
Microscopic examination results
Chronic Myelocytic Leukemia (CML)
Thank you!