Page 1: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Experience the true meaning of service and quality. www.tamco.ca

THERMALLY INSULATED DAMPERS

LOUVERS

AIR-FOIL CONTROL DAMPERS

BACK DRAFT DAMPERS

MULTIZONE DAMPERS

Page 2: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

TAMCO is an innovative manufacturer of high-end, quality dampers and air control products, serving commercial, industrial and institutional markets. T. A. Morrison & Co., Inc. entered the ventilation industry in 1955. In 1980, TAMCO began to produce its own line of aluminum dampers. Great attention has been devoted to design, in order to develop products which are durable, maintenance-free and unparalleled in performance.Advancements in digital control systems have been instrumental in spurring the development of TAMCO air control products. TAMCO is successfully leading the charge to bring creative solutions to the air control market.

TAMCO manufacturing plant in Stittsville (Ottawa), Ontario.

OVER 40 YEARS OF EXPERIENCE IN INNOVATIVE AIR CONTROL SOLUTIONS

• TAMCO’s creative design and material matrix provide for durable and dependable components.

• TAMCO’ssoundworkmanshipensures product integrity.

• TAMCO’s dampers undergoexacting quality control checks at every stage of production.

COMMITMENT TO QUALITY

TAMCO ... the leader in innovative damper technology.

Page 3: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

TAMCO ... the leader in innovative damper technology.

STAY CURRENT!For the most up-to-date catalog content, visit our web site.

For downloadable, printer-friendly: Specification sheets Suggested Specification documents Performance Data sheets Installation Guidelines Technical Data sheets

visit

www.tamco.ca

Page 4: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

TABLE OF CONTENTST A M C O C A T A L O G

TAMCO POLICIESLimited Product Warranty 1Standard Terms & Conditions of Sale 2

TAMCO THERMALLY INSULATED DAMPERSSeries 9000 BF Thermally Broken Frame Damper Product Information 3Series 9000 ECT Extreme Cold Temperature Damper Product Information 6Series 9000 BF & 9000 ECT Performance Data 7Series 9000 BF Specifications 9Series 9000 ECT Specifications 10Series 9000 Thermally Insulated Damper Product Information 11Series 9000 SC Severe Cold Temperature Damper Product Information 13Series 9000 SW Thermally Insulated Salt Water Resistance Damper Product Information 14Series 9000, 9000 SC & 9000 SW Performance Data 15Series 9000 Specifications 16Series 9000 SC Specifications 17Series 9000 SW Specifications 18Series 9000 BF, 9000 ECT, 9000, 9000 SC & 9000 SW Pressure Drop 19Series 9000 BF, 9000 ECT, 9000, 9000 SC & 9000 SW Free Area Charts 20

TAMCO LOW-LEAKAGE, AIR-FOIL CONTROL DAMPERSSeries 1500 Enhanced Air-foil Control Damper Product Information 21Series 1500 SW Enhanced Air-foil Control Salt Water Resistance Damper Product Information 22Series 1500 & 1500 SW Performance Data 24Series 1500 Specifications 25Series 1500 SW Specifications 26Series 1000 Air-foil Control Damper Product Information 27Series 1000 & 1000 SW Performance Data 28Series 1000 Specifications 29Series 1000 SW Specifications 30Series 1500, 1500 SW, 1000 & 1000 SW Pressure Drop 31Series 1500, 1500 SW, 1000 & 1000 SW Free Area Charts 32Series 1400 - 4” Wide Air-foil Blade Damper Product Information 33Series 1400 & 1400 SW Free Area Charts 34Series 1400 Specifications 35Series 1400 SW Specifications 36Series 1000 MZ Two-Deck Multizone Damper Product Information 37Series 1000 MZ Specifications 39Series 1000 MZ Dimensional Parameters 40

TAMCO BACK DRAFT DAMPERSSeries 7000, 7000 WT & 7000 CW Back Draft Damper Product Information 41Series 7000 Back Draft Damper Specifications 43Series 7000 Performance Data 44Series 7000 WT Weighted Back Draft Damper Specifications 45Series 7000 WT Performance Data 46Series 7000 CW Counterweighted Back Draft Damper Specifications 47Series 7000 CW Performance Data 48

Page 5: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

TABLE OF CONTENTST A M C O C A T A L O G

TAMCO FIXED BLADE LOUVERSSeries 3000 & 4000 Fixed Blade Louver Product Information 49Series 3000 & 4000 Performance Data 50Series 3000 & 4000 Specifications 51Series 3000 & 4000 Free Area Charts 52

TAMCO INSECT SCREENSSeries 6000 Insect Screen Product Information 53Series 6000 Specifications 54

TAMCO DAMPER OPTIONSFace & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55Face & Bypass Standard Configurations 56Square-to-Round Transition for Series 9000 BF, 9000 ECT, 9000, 9000 SC, 9000 SW, 571500, 1500 SW, 1000 & 1000 SW

TAMCO ALUMINUM DAMPER STANDARD CONFIGURATIONS(SERIES 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW)One-Section-Wide Dampers 58Two-Sections-Wide Dampers 59Three-Sections-Wide Dampers 61Four-Sections-Wide Dampers 63

LINKING MULTIPLE SECTIONS FOR ALUMINUM DAMPERS(SERIES 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW)Multiple-Section Horizontal Jack Shafts 65Configurations Using Vertical Jack Shafts 66Multiple-Section Damper Jumpers 67

TAMCO ALUMINUM DAMPER TORQUE REQUIREMENTS(SERIES 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW)Torque Requirements Charts 68

TAMCO ALUMINUM DAMPER INSTALLATION GUIDELINES(SERIES 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW)Installation Guidelines 69Motor Mounting Methods 72Structural Design Requirements 73Troubleshooting 74Installation of Vertical Blade Dampers 75Installation Guidelines/Horizontal Jack Shafts 76Installation Guidelines/Vertical Jack Shafts 77Installation Guidelines/Damper Jumpers 78

LINEARITY INFORMATION(SERIES 1000/1500/9000)Sizing Flow Control Dampers 79Flow Characteristics 79General Sizing Guidelines 80Sizing Criteria - Other Cases 81

SOUND RATINGS(SERIES 1000/1500)Sound Ratings Charts 82

Page 6: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

LIMITED PRODUCT WARRANTYT A M C O P O L I C I E S

Products manufactured by TAMCO are warranted to be free from defects in material and workmanship for a period of 12 months after being installed or placed in service, but in no instance shall the period or warranty be longer than 18 months from the date of original shipment by TAMCO. TAMCO warrants only that it will furnish replacement material, or at its option, repair any productofitsmanufacturethatisproventoTAMCO’ssatisfactionto be defective in material or workmanship during this described warranty period.

Products not manufactured by TAMCO will be warranted by TAMCO only to the extent that they are warranted to TAMCO by their manufacturer. TAMCO shall have no responsibility for the operation or performance of any products in any manner other than that for which the product is usually tested and applied under industry standards, nor for any damage to a product from abuse, misapplication, unauthorized repairs, abrasion, erosion, corrosion, or the like due to abnormal temperatures, or the influence of foreign matter, nor for the design or operation of any system of which any product may be made a part, or for the suitability of any product for any particular application. TAMCO shall not be liable for any cost or expense, including without limitation, labor expenses, in connection with removal or replacement of alleged defective equipment or any part or portion thereof nor for incidental or consequential damages of any kind, or under any circumstances for any damage beyond the price of the goods sold.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXCEPT THAT OF TITLE, WHETHER WRITTEN, ORAL OR IMPLIED, IN FACT OR IN LAW (INCLUDING ANY WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE).

Correction of non-conformities, whether patent or latent, in the manner and within the period of time provided above, shall constitute fulfillment of all liabilities of TAMCO whether based on contract, tort, strict liability or other legal theory with respect to TAMCO’sproducts.TAMCOneitherassumes,nordoesitauthorizeany other person to assume on its behalf, any other liability in connection with the sale of its products.

Contact your TAMCO sales representative if inquiring about the bearing warranty.

1

Page 7: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

STANDARD TERMS & CONDITIONS OF SALESales by T. A. Morrison & Co. Inc. (TAMCO) are subject to the following terms and conditions. No terms or conditions

appearing in buyers’ purchase orders that are contrary to the following terms and conditions shall be binding on TAMCO unless specifically agreed to in writing.

Credit Approval: All orders require credit approval prior to acceptance. Any order containing terms of payment that have not specifically been agreed to in writing, prior to receipt, will be held pending clarification of terms and receipt of documents confirming mutually agreed terms.

Shipping for orders to open-account shipment will be held pending receipt of all necessary credit information required to extend open-account terms. Orders from customers who have not had previous credit approval can be processed immediately, if a check for the appropriate amount accompanies the order.

Terms of Payment: Open-account payment terms are net 30 days with no discounts or retainages. These terms are available only on qualified U.S.A. and Canadian sales.

Proposals & Price Quotations: Any quotation from TAMCO to Buyer will be an invitation for an offer from Buyer upon the terms and conditions as stated. Such offer will be accepted only if it is in accordance with these terms and conditions. TAMCO’sacceptanceofBuyer’sorder,asevidencedbyTAMCO’sorderacknowledgment,isexpresslymadeconditionalonBuyer’sagreementtoallofthetermsand conditions stated, and TAMCO agrees to furnish the products ordered by Buyer only upon these terms and conditions.

Prices: Unless otherwise specifically agreed, prices are valid for goods required for delivery within 90 days of acceptance only. Thereafter, TAMCO will notify Buyer of any price change prior to delivery.

Shipments: All shipments are made F.O.B. shipping point with full freight allowed, or prepaid and add (as applicable), to any point in the contiguous United States, or Canada. Delivery to the initial carrier constitutes delivery and passage of title to Buyer. Incident to the passage of title, Buyer assumes all responsibilities of ownership, including but not limited to control, risk of loss, or damages; regardless of the time or method of shipping, the form of the shipping documents, the consignee, the method of insuring or the terms or method of payment. The terms F.O.B., F.A.S., C.I.F., etc. refer only to the price and not the time or place the title to the products passes from TAMCO to Buyer.

Delivery: Scheduled shipping dates shown in TAMCO’s orderacknowledgements are approximate and represent the best estimate of shipping date at the time the order is processed. TAMCO assumes no obligation to ship on the scheduled date, or to advise Buyer that shipment will be delayed. TAMCO shall have no liability for any liquidated damages or penalty whatsoever because of failure to ship as scheduled, unless specifically agreed to in writing.

Shortages or Deficiencies: Any shortages or deficiencies in material shipped must be reported within 14 calendar days after receipt to be considered by TAMCO for adjustment.

Warranty: Only TAMCO’sstandard“LimitedProductWarranty”will apply to new product sales.

Resale & Reshipments: The Buyer agrees that products purchased will not be reshipped or resold to any persons or places prohibited by the laws of the United States of America or Canada.

Return of Material: Effectively all TAMCO products are fabricated toacustomer’sspecificorder.TAMCO does not maintain a stock of products. Therefore, return of material for credit cannot be allowed. No material is to be returned for any reason without prior written authorization from TAMCO, within the terms of our warranty.

Product Changes: Because of a continuous program of product improvement, TAMCO reserves the right to make reasonable changes in product design and to supply products of revised design against any order without notice.

Changes to Order Released for Fabrication: Orders may be changed in size and quantities, if made at any time prior to starting of fabrication. Charges for these changes would be assessed relative to the expenses involved. Changes after fabrication has begun will result in charges, deemed appropriate by TAMCO, to recover the cost of material and labor expended that cannot be utilized because of the change. When shipment of an order is delayed at Buyer’srequest,aftermaterialhasbeenordered,orfabricationhasbegun, partial payment may be required, at TAMCO’soption,inanamount based on the purchase price and the percentage of work completed, at the time delay in shipment was requested.

Limitation of Liability: In no event shall TAMCO or its subcontractors or vendors be liable in contract, tort, warranty, strict liability or other legal theory for any special, indirect, incidental or consequential damages such as, but not limited to, loss of anticipated profits or revenues, non-operation or increased expense of operation of other equipment or cost of capital.

The remedies set forth herein are exclusive and the liability of TAMCO with respect to any contract or anything done in connection herewith or from the manufacture, sale, delivery, repair, replacement or use of its products covered or furnished hereunder, whether by contract, tort, warranty, strict liability or other legal theory shall not exceed the purchase price of the product upon which liability is based.

T A M C O P O L I C I E S

2

Page 8: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

L OW L E A K AG E / T H E RMA L LY I N S U L AT E DTHERMALLY BROKEN FRAMES & BLADES

S E R I E S 9 0 0 0 B F

TAMCO ... the only proven maintenance-free dampers on the market.3

Page 9: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S T A N D A R DSILICONE SEALS

A D V A N C E D I N S U L A T I N G A N D THERMAL BREAK DESIGN

•TAMCO’sThermallyInsulatedBladecombinesanaluminumshell,R-6.6polyurethanefoamandthreethermalbreaksthatresultinatrueinsulationvalueofR-2.29.

(R-value of an internal insulation medium only, is not indicative of the true R-value of a blade as a whole and is virtually negated if the metal shell is not thermally broken.)

• Optimum placement of thermal breaks isolatesthewarmandcoldsides,yetstillmaintainstheblade’sstructuralintegrity.

• Insulating foam is intrinsic to the aluminumbladeextrusionandthereforeshielded from the airstream.

• Siliconesidesealseffectivelyresistproviding a path for the conduction of heat from one side of the blade to the other. (Stainless steel or aluminum side seals create a thermal bridge for the conduction of heat.)

E N H A N C E D T H E R M A L PERFORMANCE

•TAMCO’sThermallyBrokenFrameDampers,alongwith“FlangedtoDuct”installation,areallthatisrequiredtoachieveadditionalthermalprotection,particularlyforductedexhaust,non-ductedintakeandhighhumidityapplications.

(“Installed in Duct” mounting would negate the value of the frame’s thermal breaks due to thermal bridging created by duct work.)

•TAMCO’sresearchandongoingdevelopmentprogramscontinuetoimproveandqualifydamperperformance,toaidincontrollingtheeffectsofconduction,radiation,convection,andinfiltration.

(Our aim is to produce units that interact efficiently with the building envelope.)

Thermalbreaksarethekeyto providing real insulation value.

DRY ICE TEST

Dryice:-109°F(-80°C)

Roomairtemperature:+70°F(+21°C)

TOP VIEW OF FRAME

Thermalbreaksarethekeytoprovidingrealinsulation value.

+ 70°F (+21°C)Room air temperature

-109°F (-80°C)Dry ice temperature

THERMAL INSULATING FEATURES & BENEFITS

DRY ICE TEST

4

• TheTAMCOSeries9000BFofferssiliconesealsandbladegaskets. (Silicone combines features of silica, silicate minerals, and organic compounds which result in

an inertness towards deteriorating effects of ozone, corona, weathering, and other forces, yet incorporates an extraordinary flexibility.)

• Siliconeisvirtuallyunaffectedbycoldwintertemperatures.Airleakagetestsperformedinacoldchamberrevealedthatsiliconesealsallowedonlyaminimalincreaseintheleakageratefrom40°F(4°C)to-40°F(-40°C).

(Cold box testing revealed no discernible change in flexibility or compressibility of silicone between 70°F (21°C) and -40°F (-40°C).)

• Silicone’ssuperiordynamicfatigueresistanceensureprolongedsealinglongevity,plusphenomenalresistancetoweathering,compressionset,andheat.

(Even though general-purpose silicone can withstand 500°F (260°C), the upper operating temperature of the damper unit, as a whole, is 185°F (85°C).)

• Siliconesealshaveanestimatedservicelifeof30years.

Page 10: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

T R U ETHERMAL BARRIER

•SERIES9000BFoffersathermallybrokenframethatsubstantiallyimproves the insulating value of the damper unit.

(Cooling of the frame and the internal duct work, which could lead to condensation, will be greatly reduced when the damper is closed.)

•Polyurethaneresinisolatesthewarmandcoldsides,yetstillmaintainsthestructuralintegrityoftheframe.

•Resinpockets,beingflushwithinteriorofframe,donotimpedeairflow,or reduce free area through the damper.

•Availableonlyas“FlangedtoDuct”mountingtype.Thermograms, taken from the warm side, illustrate the high heat loss to the chilling chamber of a non-

insulated damper (darker image), versus the TAMCO Thermally Insulated Damper (bright image).

32°F 23°F 14°F 5°F -4°F 13°F -22°F -31°F -40°F 0°F -5°F -10°F -15°F -20°F -25°F -30°F -35°F -40°F

@ INSIDE AIR TEMPERATURE 68°F/20°C

INSI

DE

REL

ATI

VE

HU

MID

ITY

(%

) CONDENSATION(WATER)

NON-THERMALLY BROKEN & AIR-FOIL BLADES

NO CONDENSATION

OUTSIDE AIR TEMPERATURE °F/°C

CONDENSATION(ICE)

TAMCO THERMALLY BROKEN INSULATED BLADE

BETWEEN 3°F TO -11°F WATER CAN BE EXPECTED ON THERMALLY BROKEN INSULATED BLADES.

BELOW 3°F, ICE CAN BE EXPECTED ON NON-THERMALLY BROKEN BLADES.

3°F-16°C

-11°F-24°C

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0

T H E R M A L L Y I N S U L A T E D B L A D E CONDENSATION RESISTANCE

Comparison of condensation resistance performance of thermally broken insulated blade versus non-thermally broken insulated blade and standard air foil blade.

• Thermallybrokeninsulatedbladedamperwastestedtoprovideabladetemperatureindexof55,whichisanalogoustoboththecondensationresistancefactor(CRF)ofAAMA1502.7TestMethodforCondensationResistanceofWindows,DoorsandGlazedWallSectionsandtheWindowTemperatureIndex,I,usedtospecifywindowcondensationresistanceunderCAN/CSA-A440-M90Windows,ANationalStandardofCanada.

(Temperature index is the ratio of the difference between the inside surface temperature (Tsi) and outside air temperature (To), and the difference between the inside air temperature (Ti) and outside air temperature.)

• TemperatureIndex=[Tsi-To]/[Ti-To]x100=55.Thisequationcanbe used to calculatethesurfacetemperatureforanycombinationofinsideand outside air temperatures. The resulting surface temperature can be compared to the dew point temperature of indoor air to determine if condensation will occur.

(Condensation is a function of the damper surface temperature, the inside environment temperature and the inside humidity levels. The inside surface temperature is affected by the amount of heat loss through the blade (see temperature index number), and outside cold air infiltration.)

• An effective thermal break keeps the inside surfaces warmer. This permits ahigherindoorhumiditywithoutcausingcondensation.Whencondensationdoesoccur,incasesofveryhighhumidity,itissignificantlyreducedandthisinhibits icing to colder outdoor temperatures.

• Aluminumcomponents,foaminsulationandsealinggasketsarenotaffectedbymoisture.

E N H A N C E DCONDENSATION RESISTANCE

•TAMCO’sThermallyBrokenFramewasindependentlytestedandqualifiedinordertoclarifytheimpactandbenefitsthatareachieved.Thegraphrelatingoutdoortemperaturetosurfacetemperature,plusindoorhumidityatwhichcondensationwillform,wasconstructedbycalculatingtheTemperatureIndex.

Assuming68°F(20°C)indoors,TemperatureIndicesareasfollows: 80 TAMCOThermallyBrokenFrameOption 61 non-brokendamperframe Thegraphwillallowforestimatesofframetemperatureandhumiditylevelwhich

can be supported without condensation. •TAMCO’sThermallyBrokenFrameismuchmoreresistanttocondensationandfreezinginapplicationswheredampersmustbeclosedinhighhumidityenvironments(i.e.,exhaustdampersorventsforpoolbuildings,computerrooms,museums,etc.).

(Condensation will form on any surface whose temperature is below the dew point temperature of the air to which it is exposed. Relatively small changes in temperature can make a significant difference in what indoor humidity can be sustained without condensation.)

O U T D O O R T E M P E R A T U R E

68°F 50°F 32°F 14°F -4°F -22°F -40°F 20ºC 10ºC 0ºC -10ºC -20ºC -30ºC -40ºC

SU

RF

AC

E T

EM

PE

RA

TU

RE

68°F20ºC

64°F18ºC

61°F16ºC

57°F14ºC

54°F12ºC

50°F10ºC

46°F8ºC

43°F6ºC

39°F4ºC

36°F2ºC

32°F0ºC

28°F-2ºC

25°F-4ºC IN

DO

OR

RH (A

T 68

°F (2

0°C

) AT

WH

ICH

CO

ND

ENSA

TIO

N F

ORM

S

100

88

77

68

59

52

45

39

34

30

26

22

18

Temperature Warm Side of Frame

Temperature Regular Frame

Comparison of condensation resistance performanceofthermallybrokenframevs. standard aluminum frame with insulation.

THERMAL INSULATING FEATURES & BENEFITS

5

Page 11: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

E X T R E M E C O L D T E M P E R A T U R EUPGRADE OPTION

•TheSERIES9000ECTupgradeoptionisspecificallydesignedforextremecoldtemperaturesbelow-40°F(-40°C), downto-100°F (-73°C).

•FormulaforECTsiliconesealsisthesameasthatusedbyNASAforitsAerospaceprogram.

T O T A L T H E R M A L PERFORMANCE

• TAMCO’seffectivebladeinsulationandbrokenframetechnologyisachievedbycontrollingtheforcesofradiation,convection,conduction and infiltration.

(R-value of TAMCO’s insulated damper blade falls between that of a double- and a triple-glazed thermal window.)

• TAMCO’sdesignandmaterialmatrixprovidefordurableanddependable components.

• TAMCO’sexactingqualitycontrolandsoundworkmanshipensureproductintegrity.

• TAMCOprovides,orhasavailableinstallationguidelines,technicalsupportandatoll-freecustomerservicenumber.

(Each and every TAMCO damper displays the 1-800 customer service number.)

• TAMCOproductsandpersonnelareyourguaranteeoftotalthermal performance.Minimumservicetemperaturesandbrittlepoints,asstatedbymaterialmanufacturers.

Flexibility,rigidity,andsuitabilitystatusofvariousmaterialsweredeterminedbyobservationandoperationofdampersinbothcoldroomandcoldboxenvironments.

G A S K E T S A N D S E A L S EFFECTS OF COLD

•BRITTLE POINT

•ENTIRELY FLEXIBLE

•SEMI-FLEXIBLE

°F100°F

80°F

60°F

32°F

14°F

-20°F

-30°F

-40°F

-58°F-61°F

-70°F

-76°F

-100°F

-178°F

°C38°C

27°C

16°C

0°C

-10°C

-29°C

-34°C

-40°C

-50°C-52°C

-57°C

-60°C

-73°C

-117°C

BLADE GASKET USEDBY A LEADING DAMPER

MANUFACTURER

PVC

TAMCOBLADE SEAL

(SERIES 9000/1000)

EPDM TPE SILICONE

TAMCO SIDE SEAL

(SERIES 9000/1000)

TAMCO BLADE & SIDE SEAL

(SERIES 1500/9000 SC/9000 BF)

ECT SILICONE

TAMCO BLADE & SIDE SEAL (SERIES 9000 ECT)

•RIGID/•MINIMUM

SERVICE

•ACCEPTABLE FLEXIBILITY

•ENTIRELY FLEXIBLE

•MINIMUM SERVICE

•SEMI-FLEXIBLE

•BRITTLE POINT

•BRITTLE POINT

•MINIMUM SERVICE

•BRITTLE POINT

•BRITTLE POINT

•ENTIRELY FLEXIBLE

•ENTIRELY FLEXIBLE

Material remains flexible Material has lost flexibility and/or ability to seal

•MINIMUM SERVICE

•MINIMUM SERVICE

E X T R E M E C O L D T E M P E R A T U R EU P G R A D E O P T I O N

S E R I E S 9 0 0 0 E C T

6

Page 12: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 9 0 0 0 B F & 9 0 0 0 E C T

THERMALLY BROKEN FRAME DAMPERS

7

E X T R E M E L Y

LOW LEAKAGE RATE• Extremelyflexibleextrudedsiliconesidesealsandbladegaskets

are supplied as standard.• Leakageratethrougha48”x48”(1219mm x 1219mm) TAMCO ThermallyInsulatedDamperat4”(1kPa) w.g. pressure differential tobenogreaterthan4.125cfm/ft.²(21 l/s/m²).

• Servicetemperatureofthedamperis185°F (85°C)to-40°F(-40°C) with a minimal increase in the leakage rate as temperatures decreaseto-40°F(-40°C) .

• TAMCO silicone side seals and blade gaskets eliminate infiltration ofairthatcouldreduceornullifytheeffectsofinsulation.

Pressure

Class

LEAKAGE, ft 3/min/ft 2 (l/s/m2) Required Rating Extended Ranges (Opt.)

1" / 0.25 kPa 4" / 1.0 kPa 8" / 2.0 kPa 12" / 3.0 kPa

1A 3 / 15.2 n/a n/a n/a

1 4 / 20.3 8 / 40.6 11 / 55.9 14 / 71.1

2 10 / 50.8 20 / 102 28 / 142 35 / 178

3 40 / 203 80 / 406 112 / 569 140 / 711

LeakagetestingwasconductedinaccordancewithAMCAStandard500-D-98.Holdingtorqueappliedwas5.2in.-lbs./sq.ft.onopposedbladedampersand7in.-lbs./sq.ft.onparallelbladedampersAMCAStandard500-D-98statesthatairleakageisbasedonoperationbetween50°F(10°C) and104°F(40°C). Alltestswereperformedwith120lb-inresultinginamaximumof120lb-in/ft²withthe12”x12”damper.The following sizes of TAMCO Series 9000 BF & 9000 ECT dampers were tested:12" x 12" (305 mm x 305 mm), 24" x 24" (610 mm x 610 mm), 48" x 12" (1219 mm x 305 mm)12" x 48" (305 mm x 1219 mm), 36" x 36" (914 mm x 914 mm), 60" x 36" (1524 mm x 914 mm).

LEAKAGE RATING

1 in. w.g. 4 in. w.g. 8 in. w.g.Damper Width

12" (305mm) 1A 1 11

24" (610mm) 1A 1 11

36" (914mm) 1A 1 n/a

48" (1219mm) 1A 1 n/a

60" (1524mm) 1A 1 n/a

Dampertestswereconductedinalaboratorycoldroomtodeterminetheeffectsofcolderandseverecoldtemperatures(downto-40°F(-40°C)) on sealing gaskets and leakage rates.

NOTE: Leakage rates shown in this graph are not licensed to bear the AMCA Seal. There is no AMCA standard dealing with the testing of leakage in temperatures below 50°F (10°C).

70°F 60°F 50°F 40°F 30°F 20°F 10°F 0°F -10°F -20°F -30°F -40°F21°C 15°C 10°C 4°C -1°C -7°C -12°C -18°C -23°C -29°C -34°C -40°CN

ORM

ALI

ZED

UN

IT A

IR F

LOW

(CFM

PER

SQ

UARE

FEE

T)

TEMPERATURE °F/°C

LEAKAGE THROUGH TEMPERATURE

7

6.5

6

5.5

5

4.5

4

3.5

3

2.5

2

@ 4 in. H2O

Series9000BF&9000ECTdampersexceedingthemaximum design pressure due to blade length maybeusedbyreducingthewidthofthedampersectionsand/orbyincreasingthenumberofsectionsperdampertomaintainabladewidthcompatiblewiththerequiredsystempressure.

(Example: 1 section damper of 60”w X 36”h (1524mm x 914mm) at 5” (1.24kPa) w.g. would need to be built in 2 sections of 30”w X 36”h (762mm x 914mm).)

60"

48"

36"

24"

12"3 4 5 6 7 8 9 10 11 12 13 14 15

Blad

e Le

ngth

(inc

hes)

Maximum Design Total Static Pressure (inches w.g.)

BLADE DESIGN PRESSURE LIMITATIONSMAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

Page 13: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

8

Page 14: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080”(2.03mm)inthickness.Damperframeis4”(101.6mm) deep andisinsulatedwithpolystyrofoamonfoursides.

• Entireframeisthermallybrokenbymeansofpolyurethaneresinpocketscompletewiththermalcuts.

• Bladesareextrudedaluminum(6063T5)profiles,internallyinsulatedwithexpandedpolyurethanefoamandarethermallybroken.CompletebladehasaninsulatingfactorofR-2.29andatemperatureindexof55.

• Bladeandframesealsareextrudedsiliconeandaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16”(11.11mm)aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C)and185°F(85°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Leakagedoesnotexceed3cfm/ft.²(15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Pressuredropofafullyopen48”x48”(1219mmx1219mm)damperdoesnotexceed.03”(.007kPa) w.g.at1000fpm(5.08l/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Damperisavailablein“FlangedtoDuct“mountingtype.

• Installationofdampersmustbeinaccordancewithcurrentmanufacturer’sinstallationguidelinesprovidedwitheachshipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedesand takes precedence over all information contained within the printed catalog.)

• Intermediateortubularsteelstructuralsupportisrequiredtoresistappliedpressureloadsfordampersthatconsistoftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

Note: Extreme Cold Temperature silicone for use below -40° F/C is supplied only if Series 9000 ECT Extreme Cold Temperature Option is specified. See Series 9000 ECT Specification Sheet.

S E R I E S 9 0 0 0 B F

THERMALLY BROKEN FRAME DAMPER

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

PARALLELACTION

OPPOSEDACTION

THERMALBREAKS

4"101.6mm

fully open

6"152.4mm

1"25.4mm

Note:• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in height

are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

For additional information, refer to:• Series 9000 ECT Specification Sheet• Series9000BF,9000ECT,9000,9000SC&9000SWPressureDrop• Series 9000BF,9000ECT,9000,9000SC&9000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

9

Page 15: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 9 0 0 0 E C T

EXTREME COLD TEMPERATURE OPTION

PARALLELACTION

OPPOSEDACTION

THERMALBREAKS

4"101.6mm

fully open

6"152.4mm

1"25.4mm

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080”(2.03mm)inthickness.Damperframeis4”(101.6mm) deepandisinsulatedwithpolystyrofoamonfoursides.

• Entireframeshallbethermallybrokenbymeansofpolyurethaneresinpocketscompletewiththermalcuts.

• Bladesareextrudedaluminum(6063T5)profiles,internallyinsulatedwithexpandedpolyurethanefoamandarethermallybroken.CompletebladehasaninsulatingfactorofR-2.29andatemperatureindexof55.

• Bladeandframesealsareextruded,extremelyflexiblesiliconeandsecuredinanintegralslotwithinthealuminumextrusion.SiliconeformulaisthesameasthatusedbyNASAforitsAerospaceprogram.

• Sealsremainflexibledownto-100°F(-73°C).

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16”(11.11mm)aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-100°F(-73°C)and185°F(85°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Leakagedoesnotexceed3cfm/ft.²(15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Pressuredropofafullyopen48”x48”(1219mmx1219mm)damperdoesnotexceed.03”(.007kPa) w.g.at1000fpm(5.08l/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Damperisavailablein“FlangedtoDuct“mountingtype.

• Installationofdampersmustbeinaccordancewithcurrentmanufacturer’sinstallationguidelinesprovidedwitheachshipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediateortubularsteelstructuralsupportisrequiredtoresistappliedpressureloadsfordampersthatconsistoftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

"FLANGED TO DUCT" TYPE 2" added to duct width & height dimensions

Note:• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in height

are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

For additional information, refer to:• Series9000BFSpecificationSheet• Series9000BF,9000ECT,9000,9000SC&9000SWPressureDrop• Series 9000BF,9000ECT,9000,9000SC&9000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

10

Page 16: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

L OW L E A K AG E / T H E RMA L LY I N S U L AT E DTH ERMAL LY BROKEN B LADES

S E R I E S 9 0 0 0

TAMCO ... the first manufacturer to offer a thermally insulated line of products.11

Page 17: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

E X T R E M E L YLOW LEAKAGE RATE

• ExtremelyflexibleextrudedsiliconesidesealsandperoxidecureEPDMbladegasketsaresuppliedasstandard.

(EPDMisaterpolymerofethylene,propyleneandadiene. Peroxidecurehelps to limit compression.)

• Leakageratethrougha48”x48”(1219mmx1219mm) TAMCO ThermallyInsulatedDamperat4”(1kPa) w.g. pressure differential tobenogreaterthan4.125cfm/sq.ft.(21l/s/m²).

• Servicetemperatureofthedamperis185°F(85°C)to-40°F(-40°C)with a modest increase in the leakage rate as temperatures decreaseto-40°F(-40°C).

(See comparison graph in Severe Cold Testing section; also see Severe Cold Upgrade Option.)

• SiliconeandEPDMprovideoutstandingdynamicfatigueresistancethatensuressealinglongevity,plusexcellentresistancetoweathering,compressionset,andheat.

• SiliconeandEPDMsealshaveanapproximateservicelifeof25years.

(TAMCO side seals and blade gaskets eliminate infiltration of air that could reduce or nullify the effects of insulation.)

T O T A L T H E R M A LPERFORMANCE

• TAMCO’seffectivebladeinsulationisachievedbycontrollingtheforcesofradiation,convection,conductionandinfiltration.

(R-value of TAMCO’s insulated damper blade falls between that of a double- and a triple-glazed thermal window.)

• TAMCO’sdesignandmaterialmatrixprovidesfor durable and dependable components.

• TAMCO’sexactingqualitycontrolandsoundworkmanshipensureproductintegrity.

• TAMCOprovides,orhasavailableinstallationguidelines,technicalsupportandatoll-freecustomer service number.

(Each and every TAMCO damper displays the 1-800 customer service number.)

• TAMCOproductsandpersonnelareyourguarantee of total thermal performance.

Thermograms, taken from the warm side, illustrate the high heat loss to the chilling chamber of a non-

insulated damper (darker image), versus the TAMCO Thermally Insulated Damper (bright image).

A D V A N C E D I N S U L A T I N G A N D THERMAL BREAK DESIGN

•TAMCO’sThermallyInsulatedBladecombinesanaluminumshell,R-6.6polyurethanefoamandthreethermalbreaksthatresultinatrueinsulationvalueofR-2.29.

(R-value of an internal insulation medium only, is not indicative of the true R-value of a blade as a whole and is virtually negated if metal shell is not thermally broken.)

•Optimumplacementofthermalbreaksisolatesthewarmandcoldsides,yetstill maintains the blade’sstructuralintegrity.

• Insulating foam is intrinsic to the aluminum bladeextrusionandtherefore shielded from the airstream.

•Siliconesidesealseffectivelyresistprovidingapath for the conduction of heat from one side of the blade to the other.

(Stainless steel or aluminum side seals create a thermal bridge for conduction of heat.)

-109°F (-80°C)Dry ice temperature

THERMAL INSULATING FEATURES & BENEFITS

DRY ICE TEST

+ 70°F (+21°C)Room air temperature

Thermalbreaksarethekeytoprovidingrealinsulation value.

12

Page 18: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

•Upgradeoptionofferssiliconesidesealsandbladegaskets,replacingthestandardTPEandEPDMcomponents.

(Silicone combines features of silica, silicate minerals, and organic compounds which result in an inertness towards deteriorating effects of ozone, corona, weathering, and other forces, yet incorporates an extraordinary flexibility.)

•Siliconeisvirtuallyunaffectedbycoldwintertemperatures.Airleakage tests performed in a cold chamber revealed that silicone sealsallowedonlyaminimalincreaseintheleakageratefrom40°F(4°C)to-40°F(-40°C).

(See TAMCO Severe Cold Damper Testing graphs on the interior of this brochure. Cold box testing revealed no discernible change in flexibility, or compressibility of silicone between 70°F (21°C) and -40°F (-40°C).)

•Silicone’ssuperiordynamicfatigueresistanceensuresprolongedsealinglongevity,plusphenomenalresistancetoweathering,compressionset,andheat.

(Even though general-purpose silicone can withstand 500°F (260°C), the upper operating temperature of the damper unit, as a whole, is 185° F (85°C).)

•Siliconesealshaveanestimatedservicelifeof30years.

S E V E R E C O L D UPGRADE OPTION

G A S K E T S A N D S E A L S EFFECTS OF COLD

Minimumservicetemperaturesandbrittlepoints,asstatedbymaterialmanufacturers.Flexibility,rigidity,andsuitabilitystatusofvariousmaterialsweredeterminedbyobservationandoperationof

dampersinbothcoldroomandcoldboxenvironments.

•BRITTLE POINT

•ENTIRELY FLEXIBLE

•SEMI-FLEXIBLE

°F

60°F

32°F

14°F

-20°F

-30°F

-40°F

-58°F-61°F

-70°F

-76°F

-100°F

-120°F

°C

16°C

0°C

-10°C

-29°C

-34°C

-40°C

-50°C-52°C

-57°C

-60°C

-73°C

-84°C

•RIGID/•MINIMUM

SERVICE

•ACCEPTABLE FLEXIBILITY

•ENTIRELY FLEXIBLE

•MINIMUM SERVICE

•SEMI-FLEXIBLE

•BRITTLE POINT

•BRITTLE POINT

•MINIMUM SERVICE

•BRITTLE POINT

•ENTIRELY FLEXIBLE

Material remains flexible Material has lost flexibility and/or ability to seal

•MINIMUM SERVICE

BLADE GASKET USEDBY A LEADING DAMPER

MANUFACTURER

PVC

TAMCOBLADE SEAL

(SERIES 9000/1000)

EPDM TPE SILICONE

TAMCO SIDE SEAL

(SERIES 9000/1000)

TAMCO BLADE & SIDE SEAL

(SERIES 1500/9000 SC)

L OW L E A K AG E / T H E RMA L LY I N S U L AT E DS E V E R E C O L D O P T I O N

S E R I E S 9 0 0 0 S C

13

Dampertestswereconductedinalaboratorycoldroomtodeterminetheeffectsofcolderandsevere coldtemperatures(downto-40°F(-40°C)) on sealing gaskets and leakage rates.

NOTE: Leakage rates shown in this graph are not licensed to bear the AMCA Seal.There is no AMCA standard dealing with the testing of leakage in temperatures below 50°F (10°C).

S T A N D A R D V S . S I L I C O N E U P G R A D E O P T I O N LEAKAGE COMPARISON GRAPH

70°F 60°F 50°F 40°F 30°F 20°F 10°F 0°F -10°F -20°F -30°F -40°F21°C 15°C 10°C 4°C -1°C -7°C -12°C -18°C -23°C -29°C -34°C -40°CN

ORM

ALI

ZED

UN

IT A

IR F

LOW

(CFM

PER

SQ

UARE

FEE

T)

TEMPERATURE °F/°C

LEAKAGE THROUGH TEMPERATURE

7

6.5

6

5.5

5

4.5

4

3.5

3

2.5

2

@ 4 in. H2O

STANDARD TPE & EPDM SEALS & GASKETS

SEVERE COLD SILICONE OPTION

9000 TPE & EPDM 9000 SILICONE

Page 19: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

Applications:•Ideallysuitedforcoastalclimates.

•Recommendedforinlandapplications,wheretiresprayfromwinter-saltedroadshasbeenknowntocorrodedampersinstalledincloseproximitytoroadsorhighways.

Silicone blade gaskets

Anodized pivot rods

Type 316 Stainless steel cup-point fasteners

Type 316 Stainless steel

trunnions

Siliconeside seals

Type 316 Stainless steel

drive rod

Type 316 Stainless steel

fasteners

Anodizedblades & frames

Type 316 Stainless steel frame assembly screws

Anodized linkage rods

Anodized crank arm

Anodized opposed blade jumper

(when required)

L OW L E A K AG E / T H E RMA L LY I N S U L AT E DSALT WATER RESISTANCE

S E R I E S 9 0 0 0 S W

14

Also available: Series 1000 SW, 1500 SW & 1400 SW VisitTAMCOwebsiteformoreinformation.

Page 20: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Thermallybrokeninsulatedbladedamperwastestedtoprovideabladetemperatureindexof55,whichisanalogoustoboththecondensationresistancefactor(CRF)ofAAMA1502.7TestMethodforCondensationResistanceofWindows,DoorsandGalvanizedWallSectionsandtheWindowTemperatureIndex,I,usedtospecifywindowcondensationresistanceunderCAN/CSA-A440-M90Windows,ANationalStandardofCanada.

(Temperature index is the ratio of the difference between the inside surface temperature (Tsi) and outside air temperature (To), and the difference between the inside air temperature (Ti) and outside air temperature.)

• TemperatureIndex=[Tsi-To]/[Ti-To]x100=55.Thisequationcanbeusedtocalculate thesurfacetemperatureforanycombinationofinsideandoutsideairtemperatures.Theresulting surface temperature can be compared to the dew point temperature of indoor air to determine if condensation will occur.

(Condensation is a function of the damper surface temperature, the inside environment temperature and the inside humidity levels. The inside surface temperature is affected by the amount of heat loss through the blade (see temperature index number), and outside cold air infiltration.)

• An effective thermal break keeps the inside surfaces warmer. This permits a higher indoorhumiditywithoutcausingcondensation.Whencondensationdoesoccur,incasesofveryhighhumidity,itissignificantlyreducedandthisinhibitsicingtocolderoutdoortemperatures.

• Aluminumcomponents,foaminsulationandsealinggasketsarenotaffectedbymoisture.

Comparison of condensation resistance performance of thermally broken insulated blade versus non-thermally broken insulated blade and standard air-foil blade.

T H E R M A L L Y I N S U L A T E D B L A D E CONDENSATION RESISTANCE

32°F 23°F 14°F 5°F -4°F 13°F -22°F -31°F -40°F 0°F -5°F -10°F -15°F -20°F -25°F -30°F -35°F -40°F

@ INSIDE AIR TEMPERATURE 68°F/20°C

INSI

DE

REL

ATI

VE

HU

MID

ITY

(%

)

CONDENSATION(WATER)

NON-THERMALLY BROKEN & AIR-FOIL BLADES

NO CONDENSATION

OUTSIDE AIR TEMPERATURE °F/°C

CONDENSATION(ICE)

TAMCO THERMALLY BROKEN INSULATED BLADE

BETWEEN 3°F TO -11°F WATER CAN BE EXPECTED ON THERMALLY BROKEN INSULATED BLADES.

BELOW 3°F, ICE CAN BE EXPECTED ON NON-THERMALLY BROKEN BLADES.

3°F-16°C

-11°F-24°C

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0

S E R I E S 9 0 0 0 , 9 0 0 0 S C & 9 0 0 0 S W

THERMALLY INSULATED DAMPERS

15

Pressure

Class

LEAKAGE, ft 3/min/ft 2 (l/s/m2) Required Rating Extended Ranges (Opt.)

1" / 0.25 kPa 4" / 1.0 kPa 8" / 2.0 kPa 12" / 3.0 kPa

1A 3 / 15.2 n/a n/a n/a

1 4 / 20.3 8 / 40.6 11 / 55.9 14 / 71.1

2 10 / 50.8 20 / 102 28 / 142 35 / 178

3 40 / 203 80 / 406 112 / 569 140 / 711

LeakagetestingwasconductedinaccordancewithAMCAStandard500-D-98.Holdingtorqueappliedwas5.2in.-lbs./sq.ft.onopposedbladedampersand7in.-lbs./sq.ft.onparallelbladedampers.AMCAStandard500-D-98statesthatairleakageisbasedonoperationbetween50°F(10°C) and104°F(40°C). Alltestswereperformedwith120lb-inresultinginamaximumof120lb-in/ft²withthe12”x12”damper.The following sizes of TAMCO Series 9000, 9000 SC & 9000 SW dampers were tested:12" x 12" (305 mm x 305 mm), 24" x 24" (610 mm x 610 mm), 48" x 12" (1219 mm x 305 mm)12" x 48" (305 mm x 1219 mm), 36" x 36" (914 mm x 914 mm), 60" x 36" (1524 mm x 914 mm).

LEAKAGE RATING

1 in. w.g. 4 in. w.g. 8 in. w.g.Damper Width

12" (305mm) 1A 1 11

24" (610mm) 1A 1 11

36" (914mm) 1A 1 n/a

48" (1219mm) 1A 1 n/a

60" (1524mm) 1A 1 n/a

AllSeries9000,9000SC&9000SWdampersexceedingthemaximumdesignpressureduetobladelengthmaybeusedbyreducingthewidthofthedampersectionsand/orbyincreasingthenumberofsectionsperdampertomaintainabladewidthcompatiblewiththerequiredsystempressure.Example: 1 section damper of 60”w x 36”h (1525mm x 915mm) at 5” (1.24kPa) w.g.would need to be built in two sections of 30”w x 36”h (762mm x 914mm).

60"

48"

36"

24"

12"3 4 5 6 7 8 9 10 11 12 13 14 15

Blad

e Le

ngth

(inc

hes)

Maximum Design Total Static Pressure (inches w.g.)

BLADE DESIGN PRESSURE LIMITATIONSMAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

Page 21: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4"(101.6mm) deepandisinsulatedwithpolystyreneonthreesidesif"InstalledinDuct"typeandonfoursidesif"FlangedtoDuct"type.

• Bladesareextrudedaluminum (6063T5) profiles,internallyinsulatedwithexpandedpolyurethanefoamandthermallybroken.CompletebladehasaninsulatingfactorofR-2.29andatemperatureindexof55.

• BladesealsareextrudedEPDM.Framesealsareextrudedsilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledinframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C)and185°F(85°C).

• Dampers are available with either opposed blade action or parallel blade action.

• Leakagedoesnotexceed3cfm/ft.² (15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Pressuredropofafullyopen48"x48"(1219mmx1219mm)damperdoesnotexceed.03"(.007kPa) w.g.at1000fpm(5.08l/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediateortubularsteelstructuralsupportisrequiredtoresistappliedpressureloadsfordampersthatconsistoftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

NOTE: ReducedairleakageatcoldertemperaturesobtainablebyupgradingtoSeries9000SCSevereColdOption.Siliconegaskets&sealsaresuppliedonlyifSeries9000SCSevereColdOptionisspecified.

SeeSeries9000SCSpecificationSheet.

S E R I E S 9 0 0 0THERMALLY INSULATED DAMPER

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm For additional information, refer to:

• Series 9000 SC Specification Sheet• Series9000SWSpecificationSheet• Series9000BF,9000ECT,9000,9000SC&9000SWPressureDrop• Series 9000BF,9000ECT,9000,9000SC&9000SWFree Area Charts• Aluminum Standard Configurations• TAMCOAluminumDamperTorqueRequirements• Multiple-SectionHorizontalJackShafts• ConfigurationsUsingVerticalJackShafts• Multiple-SectionDamperJumpers• Square-to-RoundTransitionOption• TAMCOAluminumDamperInstallationGuidelines

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under

9 ft.² (.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in

height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

16

Page 22: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4" (101.6mm) deepandisinsulatedwithpolystyrofoamonthreesidesif"InstalledinDuct"typeandonfoursidesif"FlangedtoDuct"type.

• Bladesareextrudedaluminum (6063T5) profiles,internallyinsulatedwithexpandedpolyurethanefoamandarethermallybroken.CompletebladehasaninsulatingfactorofR-2.29andatemperatureindexof55.

• Bladeandframesealsareextrudedsiliconeandaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and185°F(85°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Leakagedoesnotexceed3cfm/ft.² (15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Pressuredropofafullyopen48”x48”(1219mmx1219mm)damperdoesnotexceed.03”(.007kPa) w.g.at1000fpm(5.08l/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediateortubularsteelstructuralsupportisrequiredtoresistappliedpressureloadsfordampersthatconsistoftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 9 0 0 0 S CSEVERE COLD OPTION

"FLANGED TO DUCT" TYPE "INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified2" added to duct width & height dimensions

For additional information, refer to:• Series 9000 Specification Sheet• Series9000SWSpecificationSheet• Series9000BF,9000ECT,9000,9000SC&9000SWPressureDrop• Series 9000BF,9000ECT,9000,9000SC&9000SWFree Area Charts• Aluminum Standard Configurations• TAMCOAluminumDamperTorqueRequirements• Multiple-Section Horizontal Jack shafts• Configurations Using Vertical Jack shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under

9 ft.² (.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in

height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

4000 SERIESMULLION TYPE

CHANNEL FRAME

3000 SERIESMULLION TYPE

EXTERIOR FLANGE

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

17

Page 23: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4" (101.6mm) deepandisinsulatedwithpolystyrofoamonthreesidesif"InstalledinDuct"typeandonfoursidesif"FlangedtoDuct"type.Aluminumframeisclearanodizedtoaminimumthicknessof0.7mil(18microns)deep.Frameisassembledusingtype316stainlesssteelscrews.

• Bladesareextrudedaluminum (6063T5) profiles,internallyinsulatedwithexpandedpolyurethanefoamandarethermallybroken.CompletebladehasaninsulatingfactorofR-2.29andatemperatureindexof55.Extrudedaluminumbladesareclearanodizedtoaminimumthicknessof0.7mil(18microns)deep.Bladeendcapsareclearanodized.Aluminumbladepivotrodsareclearanodized.

• Bladeandframesealsareextrudedsiliconeandaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframeside.Allaluminumlinkagehardwarepartsareclearanodized.Allnon-aluminumlinkagehardwarepartsaretype316stainlesssteel.Theyarecompletewithcup-pointtrunnionscrewsforslip-proofgrip.Adjustablehexagondriverod,U-bolt,andretainingnutsaretype316stainlesssteel.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and185°F(85°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Leakagedoesnotexceed3cfm/ft.²(15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Pressuredropofafullyopen48”x48”(1219mmx1219mm)damperdoesnotexceed.03”(.007kPa) w.g.at1000fpm(5.08l/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediateortubularsteelstructuralsupportisrequiredtoresistappliedpressureloadsfordampersthatconsistoftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 9 0 0 0 S WTHERMALLY INSULATED

SEVERE COLD & SALT WATER RESISTANCE DAMPER

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

For additional information, refer to:• Series 9000 Specification Sheet• Series9000SCSpecificationSheet• Series9000BF,9000ECT,9000,9000SC&9000SWPressureDrop• Series 9000BF,9000ECT,9000,9000SC&9000SWFree Area Charts• Aluminum Standard Configurations• TAMCOAluminumDamperTorqueRequirements• Multiple-Section Horizontal Jack shafts• Configurations Using Vertical Jack shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under

9 ft.² (.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in

height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

18

Page 24: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S E L E C T I O N T A B L E AREA FACTOR

Thetable(above)andthechart(below)areusedtofindthepressuredropthroughallTAMCOThermallyInsulatedDampers.1) In the above table, select the area factor value recorded, where the duct width column and duct height line meet.

2) In the chart below, enter the area factor obtained from above and the cfm for the application and read the pressure drop off where the “Area Factor” line and the “Volume Flow Rate” column meet. (Example: duct size 20”w x 32”h = .32 area factor, (above table). Then, if cfm is 2000, pressure drop = .012” w.g. (chart below).

S E L E C T I O N C H A R T PRESSURE DROP

Note: 1. Ratings are based on AMCA Standard 500, using Test Setup Apparatus Figure 5.3 (damper installed with duct upstream & downstream).2. Above Area Factor values are based on flanged-to-duct type installations. Pressure drop will be greater for installed in-duct type dampers. Call TAMCO Customer Service at

1-800-561-3449 for pressure drop calculations for installed in-duct type dampers.3. Dampers sized for duct openings exceeding 37½” (953 mm) in height are equipped with a stiffener bar at mid-height, which is reflected in the above chart.

PRESSURE LOSS,

INCHES w.g.

VOLUME FLOW RATE (CFM)

AREA

FA

CTO

R

0.010.020.040.070.1

0.150.20.30.40.50.60.70.80.91

1.21.52

2.534567

500.000025.00005.0001

.000175.00025.000375.0005.00075.001

.00125.0015.00175.002

.00225.0025.003

.00375.005

.00625.0075.01

.0125.015.0175

1000.0001.0002.0004.0007.001.0015.002.003.004.005.006.007.008.009.01.012.015.02.025.03.04.05.06.07

1500.000225.00045.0009

.001575.00225.003375.0045.00675.009

.01125.0135.01575.018

.02025.0225.027

.03375.045

.05625.0675.09

.1125.135.1575

2000.0004.0008.0016.0028.004.006.008.012.016.02.024.028.032.036.04.048.06.08.1.12.16.2.24.28

2500.000625.00125.0025

.004375.00625.009375.0125.01875.025

.03125.0375.04375

.05.05625.0625.075

.09375.125

.15625.1875.25

.3125.375.4375

3000.0009.0018.0036.0063.009.0135.018.027.036.045.054.063.072.081.09.108.135.18.225.27.36.45.54.63

4000.0016.0032.0064.0112.016.024.032.048.064.08.096.112.128.144.16.192.24.32.4.48.64.8.961.12

5000.0025.005.01

.0175.025.0375.05.075.1

.125.15.175.2

.225.25.3

.375.5

.625.751

1.251.51.75

6000.0036.0072.0144.0252.036.054.072.108.144.18.216.252.288.324.36.432.54.72.9

1.081.441.82.162.52

8000.0064.0128.0256.0448.064.096.128.192.256.32.384.448.512.576.64.768.961.281.61.922.563.23.844.48

10000.01.02.04.07.1.15.2.3.4.5.6.7.8.91

1.21.52

2.534567

15000.0225.045.09

.1575.225.3375.45.675.9

1.1251.351.5751.8

2.0252.252.7

3.3754.5

5.6256.75

911.2513.515.75

20000.0408.16.28.4.6.81.21.62

2.42.83.23.64

4.868101216202428

25000.0625.125.25

.4375.625.93751.251.8752.5

3.1253.754.375

55.6256.257.5

9.37512.5

15.62518.75

2531.2537.543.75

30000.09.18.36.63.9

1.351.82.73.64.55.46.37.28.19

10.813.518

22.52736455463

40000.16.32.641.121.62.43.24.86.48

9.611.212.814.416

19.224324048648096112

50000.25.51

1.752.53.75

57.510

12.515

17.520

22.52530

37.550

62.575100125150175

AREA FACTOR TABLE

WIDTH (inches)

HEI

GH

T (inch

es)

12162024283236404448525660

126.32

3.555

2.2752

1.58

1.1608

.8888

.7022

.5688

.4701

.395

.3366

.2902

.2528

163.555

1.9997

1.2798

.8888

.653

.4999

.395

.32

.2644

.2222

.1893

.1632

.1422

202.2752

1.2798

.8191

.5688

.4179

.32

.2528

.2048

.1692

.1422

.1212

.1045

.091

241.58

.8888

.5688

.15

.1102

.0844

.0667

.054

.0446

.0375

.032

.0276

.0241

281.1608

.653

.4179

.1102

.081

.062

.049

.0297

.0328

.0276

.0235

.0202

.0176

32.8888

.4999

.32

.0844

.062

.0475

.0375

.0304

.0251

.0211

.018

.0155

.0135

36.7022

.395

.2528

.0667

.049

.0375

.0422

.0342

.0283

.0238

.0202

.0174

.0152

40.5688

.32

.2048

.054

.0397

.0304

.0342

.0277

.0229

.0192

.0164

.0141

.0123

44.4701

.2644

.1692

.0446

.0328

.0251

.0283

.0229

.0189

.0159

.0135

.0117

.0102

48.395

.2222

.1422

.0375

.0276

.0211

.0238

.0192

.0159

.0134

.0114

.0098

.0086

52.3366

.1893

.1212

.032

.0235

.018

.0202

.0164

.0135

.0114

.0097

.0084

.0073

56.2902

.1632

.1045

.0276

.0202

.0155

.0174

.0141

.0117

.0098

.0084

.0072

.0063

60.2528

.1422

.091

.024

.0176

.0135

.0152

.0123

.0102

.0086

.0073

.0063

.0055

PRESSURE DROP

SER I ES 9000 BF, 9000 ECT, 9000 , 9000 SC & 9000 SW

19

Page 25: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

FREE AREA CHARTS

M E T E R S S Q U A R E D 305 610 915 1220 1525 1829 2134 2439 2744 3048 0.06 0.12 0.19 0.25 0.31 0.35 0.41 0.47 0.54 0.60 0.03 0.07 0.12 0.16 0.20 0.23 0.28 0.32 0.36 0.40 0.14 0.28 0.42 0.56 0.70 0.79 0.93 1.07 1.21 1.35 0.09 0.21 0.33 0.45 0.57 0.66 0.78 0.90 1.02 1.14 0.21 0.42 0.63 0.84 1.05 1.18 1.39 1.60 1.81 2.02 0.14 0.34 0.53 0.73 0.93 1.08 1.28 1.47 1.67 1.87 0.28 0.56 0.84 1.11 1.39 1.58 1.86 2.14 2.42 2.69 0.19 0.46 0.72 0.99 1.26 1.46 1.73 1.99 2.26 2.53 0.36 0.71 1.07 1.42 1.78 2.02 2.37 2.73 3.09 3.44 0.24 0.58 0.91 1.25 1.59 1.84 2.18 2.51 2.85 3.19 0.43 0.87 1.30 1.73 2.10 2.46 2.89 3.32 3.61 4.05 0.29 0.71 1.12 1.54 1.85 2.26 2.68 3.09 3.37 3.78 0.48 0.96 1.44 1.92 2.40 2.72 3.20 3.68 4.16 4.64 0.33 0.79 1.25 1.71 2.17 2.51 2.98 3.44 3.90 4.36 0.54 1.08 1.63 2.17 2.71 3.07 3.61 4.15 4.70 5.24 0.38 0.92 1.46 2.00 2.53 2.94 3.48 4.01 4.55 5.09 0.62 1.24 1.86 2.48 3.10 3.51 4.13 4.75 5.37 5.99 0.44 1.05 1.67 2.28 2.90 3.36 3.98 4.59 5.21 5.82 0.70 1.39 2.09 2.79 3.48 3.95 4.65 5.34 6.04 6.74 0.48 1.16 1.83 2.51 3.19 3.70 4.38 5.05 5.73 6.41

305

610

915

1220

1525

1829

2134

2439

2744

3048

WIDTH (mm)

HEI

GHT

(mm

)

F E E T S Q U A R E D

WIDTH (inches)HEI

GHT

(inch

es)

12 24 36 48 60 72 84 96 108 120 0.67 1.33 2.00 2.67 3.33 3.78 4.44 5.11 5.78 6.44 0.32 0.78 1.24 1.70 2.16 2.50 2.96 3.42 3.88 4.34 1.50 3.00 4.50 6.00 7.50 8.50 10.00 11.50 13.00 14.50 0.91 2.21 3.50 4.79 6.08 7.05 8.34 9.63 10.93 12.22 2.25 4.50 6.75 9.00 11.25 12.75 15.00 17.25 19.50 21.75 1.51 3.63 5.76 7.88 10.01 11.60 13.72 15.85 17.97 20.10 3.00 6.00 9.00 12.00 15.00 17.00 20.00 23.00 26.00 29.00 2.04 4.91 7.79 10.66 13.54 15.69 18.57 21.44 24.32 27.19 3.83 7.67 11.50 15.33 19.17 21.72 25.56 29.39 33.22 37.06 2.57 6.19 9.82 13.44 17.07 19.79 23.41 27.04 30.66 34.29 4.67 9.33 14.00 18.67 22.56 26.44 31.11 35.78 38.89 43.56 3.16 7.62 12.07 16.53 19.88 24.34 28.79 33.25 36.22 40.68 5.17 10.33 15.50 20.67 25.83 29.28 34.44 39.61 44.78 49.94 3.51 8.47 13.43 18.39 23.35 27.06 32.02 36.98 41.94 46.90 5.83 11.67 17.50 23.33 29.17 33.06 38.89 44.72 50.56 56.39 4.10 9.89 15.69 21.48 27.27 31.61 37.40 43.20 48.99 54.78 6.67 13.33 20.00 26.67 33.33 37.78 44.44 51.11 57.78 64.44 4.69 11.32 17.94 24.57 31.19 36.16 42.79 49.41 56.04 62.66 7.50 15.00 22.50 30.00 37.50 42.5 50.00 57.50 65.00 72.50 5.16 12.46 19.75 27.04 34.33 39.80 47.09 54.38 61.68 68.97

12

24

36

48

60

72

84

96

108

120

P E R C E N T A G E

12 24 36 48 60 72 84 96 108 120 66.67 66.67 66.67 66.67 66.67 62.96 63.49 63.89 64.20 64.44 32.47 39.15 41.38 42.49 43.16 41.70 42.29 42.73 43.07 43.35 75.00 75.00 75.00 75.00 75.00 70.83 71.43 71.88 72.22 72.50 45.75 55.16 58.30 59.87 60.82 58.75 59.59 60.21 60.70 61.09 75.00 75.00 75.00 75.00 75.00 70.83 71.43 71.88 72.22 72.50 50.17 60.50 63.95 65.67 66.70 64.44 65.35 66.04 66.57 67.00 75.00 75.00 75.00 75.00 75.00 70.83 71.43 71.88 72.22 72.50 50.91 61.39 64.89 66.63 67.68 65.39 66.31 67.01 67.55 67.98 76.77 76.67 76.67 76.67 76.67 72.41 73.02 73.47 73.83 74.11 51.35 61.93 65.45 67.21 68.27 65.95 66.89 67.59 68.14 68.57 77.78 77.78 77.78 77.78 75.19 73.46 74.07 74.54 72.02 72.59 52.63 63.47 67.08 68.89 66.26 67.60 68.56 69.27 67.08 67.80 73.81 73.81 73.81 73.81 73.81 69.71 70.29 70.73 71.08 71.35 50.17 60.50 63.95 65.67 66.70 64.44 65.35 66.04 66.57 67.00 72.92 72.92 72.92 72.92 72.92 68.87 69.44 69.88 70.22 70.49 51.28 61.84 65.36 67.12 68.17 65.86 66.79 67.49 68.04 68.47 74.07 74.07 74.07 74.07 74.07 69.96 70.55 70.99 71.33 71.60 52.14 62.88 66.45 68.24 69.32 66.97 67.92 68.63 69.18 69.62 75.00 75.00 75.00 75.00 75.00 70.83 71.43 71.88 72.22 72.50 51.65 62.28 65.83 67.70 68.66 63.33 67.27 67.98 68.53 68.97

12

24

36

48

60

72

84

96

108

120

HEI

GHT

(inch

es)

WIDTH (inches)

• Toreducepressuredrop,use"FlangedtoDuct" type for sizes under 9 ft.² (.83m2).

• Damperssizedforductopeningsexceeding37½" (953mm) in height are equipped with a stiffener bar at mid-height, to strengthen and maintain air leakage tolerances.

NOTE:

FLANGED TO DUCT

INSTALLED IN DUCT

SER I ES 9000 BF, 9000 ECT, 9000 , 9000 SC & 9000 SW

20

Page 26: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

U LT R A L OW L E A K AG E / S I L I C ON E S E A L SENHANCED AIR-FOIL CONTROL

S E R I E S 1 5 0 0

S I L I C O N E

BLADE AND FRAME SEALS

• Siliconebladeandframesealsoutperformallotherexistingsealsduetoflexibilityanddurability. (Silicone seals have an estimated service life of 30 years.)

•Siliconesealsarevirtuallyunaffectedbycoldoperatingtemperatures.Airleakagetestsundertakeninacoldchamberrevealedthatsiliconesealsallowedonlyaminimalincreaseinleakageratesbetween40ºF (4ºC)and-40ºF (-40º C).

•Silicone’ssuperiordynamicfatigueresistanceensuresprolongedsealinglongevity,plusphenomenalresistancetoweathering,compressionset,andheat. (Even though general purpose silicone can withstand 500ºF (260ºC), the upper operating temperature of the damper unit as a whole is 212ºF (100ºC).)

21

Page 27: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

BrandX-Stainlesssteeldamper BrandY-Galvanizeddamper

CHANGE IN TORQUE(in.-lbs.)

TAMCO 1500 SW

Opening

Closing

0.0 2.5 0.5

0.0 1.7 1.5

StainlessSteel Galvanized

C H A N G E I N T O R Q U E R E Q U I R E M E N T S1000 HRS. IN SALT SPRAY CHAMBER

I N A S T M B 1 1 7

SALT WATER SPRAY TESTING• TheTAMCOSeries1500SW,aBrandXstainlesssteeldamperandaBrandYgalvanizeddamperwereexposedto1000hoursoftestinginaSingletonsaltspraycabinet.• Basetorquereadingsweretakenbeforetesting.Changesinopeningandclosingtorquereadingswererecordedastestingprogressed.• Sampleswereevaluatedforchangesinsurfacefinishesanddegreeofrusting.• TheTAMCOSeries1500SWdamper'sopeningandclosingtorqueswereunchangedafter1000hoursofsaltwaterspraytesting.• ThesurfaceoftheSeries1500SWdampershowednochangeotherthanasmallaccumulationofsaltresidue,whichwaseasilywipedoffwithadampcloth.• Resultsfortheappearanceandchangeintorquerequirementsforthestainlesssteelandgalvanizeddampersareshownbelow.

Applications:•Ideallysuitedforcoastalclimates.

•Recommendedforinlandapplications,wheretiresprayfromwinter-saltedroadshasbeenknowntocorrodedampersinstalledincloseproximitytoroadsorhighways.

Also available: Series 1000 SW, 9000 SW & 1400 SWVisitTAMCOwebsiteformoreinformation.

Silicone blade gaskets

Anodized pivot rods

Type 316 Stainless steel cup-point fasteners

Type 316 Stainless steel

trunnions

Siliconeside seals

Type 316 Stainless steel

drive rod

Type 316 Stainless steel

fasteners

Anodizedblades & frames

Type 316 Stainless steel frame assembly screws

Anodized linkage rods

Anodized crank arm

Anodized opposed blade jumper

(when required)

U LT R A L OW L E A K AG E / S I L I C ON E S E A L SSALT WATER RESISTANCE

S E R I E S 1 5 0 0 S W

OUTPERFORMS STAINLESS & GALVANIZED STEEL

22

Page 28: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

23

Page 29: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

TAMCO LEAKAGE RATING

1 in. w.g. 4 in. w.g. 8 in. w.g.Damper Width

12" (305mm) 1A 1A 1A

24" (610mm) 1A 1A 1A

36" (914mm) 1A 1A 1A

48" (1219mm) 1A 1A n/a

60" (1524mm) 1A 1A n/a

Pressure

Class

LEAKAGE, ft 3/min/ft 2 (l/s/m2) Required Rating Extended Ranges (Opt.)

1" / 0.25 kPa 4" / 1.0 kPa 8" / 2.0 kPa 12" / 3.0 kPa

1A 3 / 15.2 8 / 40.6 11 / 55.9 14 / 71.1

1 4 / 20.3 8 / 40.6 11 / 55.9 14 / 71.1

2 10 / 50.8 20 / 102 28 / 142 35 / 178

3 40 / 203 80 / 406 112 / 569 140 / 711

LEAKAGE CLASS DEFINITIONS

S E R I E S 1 5 0 0 & 1 5 0 0 S WENHANCED AIR-FOIL DAMPERS

1.00.90.80.70.60.50.4

0.3

0.2

0.1

0.08

0.060.050.04

0.03

0.02

0.01

Pres

sure

Dro

p (in

ches

w.g

.)(in

take

mod

e)

VELOCITY VS. PRESSURE DROP

48" x 12"(1219mm x 305mm)

12" x 12"(305mm x 305mm)

12" x 48"(305mm x 1219mm)

24" x 24"(610mm x 610mm)

36" x 36"(914mm x 914mm)

Face Velocity (ft./min.)AMCA Figure 5.3

100 500 1,000 5,000 10,000

Series1500&1500SWdampersexceedingthemaximum design pressure due to blade length maybeusedbyreducingthewidthofthedampersectionsand/orbyincreasingthenumberofsectionsperdampertomaintainabladewidthcompatiblewiththerequiredsystempressure.

(Example: 1 section damper of 60”w X 36”h (1524mm x 914mm) at 5” (1.24kPa) w.g. would need to be built in 2 sections of 30”w X 36”h (762mm x 914mm).)

60"

48"

36"

24"

12"3 4 5 6 7 8 9 10 11 12 13 14 15

Blad

e Le

ngth

(inc

hes)

Maximum Design Total Static Pressure (inches w.g.)

BLADE DESIGN PRESSURE LIMITATIONSMAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

24

T.A.Morrison&Co.Inc.certifiesthattheTAMCOSeries1500&1500SWEnhancedAir-FoilControl Damper shown herein are licensed to bear the AMCA Seal. The ratings shown are basedontestsandproceduresperformedinaccordancewithAMCAPublication511andcomplywiththerequirementsoftheAMCACertifiedRatingsProgram.TheAMCACertifiedRatings Seal applies to air performance ratings and air leakage ratings.

LeakagetestingwasconductedinaccordancewithAMCAStandard500-D-98.Holdingtorqueappliedwas5.2in.-lbs./sq.ft.AMCAStandard500-D-98statesthatairleakageisbasedonoperationbetween50°F(10°C) and104°F(40°C). Alltestswereperformedwith120lb-inresultinginamaximumof120lb-in/ft²withthe12”x12”damper.The following sizes of TAMCO Series 1500 dampers were tested:12" x 12" (305 mm x 305 mm), 24" x 24" (610 mm x 610 mm), 48" x 12" (1219 mm x 305 mm)12" x 48" (305 mm x 1219 mm), 36" x 36" (914 mm x 914 mm), 60" x 36" (1524 mm x 914 mm).

TAMCO MAY 2008 / PRINTED IN CANADA

Page 30: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4" deep.

• Bladesareextrudedaluminum(6063T5)profiles.Aluminumendcapsarepressfittedtobladeendsinordertosealhollowinterior and reduce air leakage rates.

• Bladeandframesealsareextrudedsiliconeandaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• LeakageClass1Aat1”w.g.staticpressuredifferential.StandardairleakagedataiscertifiedundertheAMCACertifiedRatingsProgram.

• Pressuredropofafullyopen48"x48"(1219mmx1219mm)damperdoesnotexceed.02"(.004kPa) w.g.at1000fpm(5.08m/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of two ormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

TAMCO MAY 2008 / PRINTED IN CANADA

S E R I E S 1 5 0 0ENHANCED AIR-FOIL DAMPER

4000 SERIESMULLION TYPE

CHANNEL FRAME

3000 SERIESMULLION TYPE

EXTERIOR FLANGE

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

"FLANGED TO DUCT" TYPE "INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under

9 ft.² (.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in

height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

For additional information, refer to:• Series 1500 SWSpecification Sheet• Series 1500,1500SW,1000&1000SWPressureDrop• Series 1500,1500SW,1000&1000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

25

Page 31: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

TAMCO MAY 2008 / PRINTED IN CANADA

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080” (2.03mm) inthickness.Damperframeis4” deep. Aluminumframeisclearanodizedtoaminimumthicknessof0.7mil(18microns)deep.Frameisassembledusingtype316stainlesssteelscrews.

• Extrudedaluminumbladesareclearanodizedtoaminimumthicknessof0.7mil(18microns) deep. Aluminum end caps are pressfittedtobladeendsinordertosealhollowinteriorandreduceairleakagerates.Endcapsandaluminumbladepivotrodsareclearanodized.

• Bladeandframesealsareextrudedsiliconeandaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframeside.Allaluminumlinkagehardwarepartsareclearanodized.Allnon-aluminumlinkagehardwarepartsaretype316stainlesssteel.Theyarecompletewithcup-pointtrunnionscrewsforslip-proofgrip.Adjustablehexagondriverod,U-bolt,andretainingnutsaretype316stainlesssteel.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• LeakageClass1Aat1”w.g.staticpressuredifferential.StandardairleakagedataiscertifiedundertheAMCACertifiedRatingsProgram.

• Pressuredropofafullyopen48"x48" (1219mmx1219mm)damperdoesnotexceed.02"(.004kPa) w.g.at1000fpm(5.08m/s).

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of twoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 1 5 0 0 S WSALT WATER RESISTANCE ENHANCED AIR-FOIL DAMPER

4000 SERIESMULLION TYPE

CHANNEL FRAME

3000 SERIESMULLION TYPE

EXTERIOR FLANGE

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

"FLANGED TO DUCT" TYPE "INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for

sizes under 9 ft.² (.83m2).• Suitable for operation in breathable air environments within

stated temperature range.• Dampers sized for duct openings exceeding 37½" (953mm)

in height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• Not available as 4" only blade type.

For additional information, refer to:• Series 1500 Specification Sheet• Series 1500,1500SW,1000&1000SWPressureDrop• Series 1500,1500SW,1000&1000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

26

Page 32: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

L OW L E A K AG E / M A I N T E N AN C E - F R E EAIR-FOIL CONTROL DAMPER

S E R I E S 1 0 0 0

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalogue.27

Page 33: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 1 0 0 0 & 1 0 0 0 S WAIR-FOIL CONTROL DAMPERS

1.00.90.80.70.60.50.4

0.3

0.2

0.1

0.08

0.060.050.04

0.03

0.02

0.01

Pres

sure

Dro

p (in

ches

w.g

.)(in

take

mod

e)

VELOCITY VS. PRESSURE DROP

48" x 12"(1219mm x 305mm)

12" x 12"(305mm x 305mm)

12" x 48"(305mm x 1219mm)24" x 24"(610mm x 610mm)

36" x 36"(914mm x 914mm)

Face Velocity (ft./min.)AMCA Figure 5.3

100 500 1,000 5,000 10,000

Series1000&1000SWdampersexceedingthemaximum design pressure due to blade length maybeusedbyreducingthewidthofthedampersectionsand/orbyincreasingthenumberofsectionsperdampertomaintainabladewidthcompatiblewiththerequiredsystempressure.

(Example: 1 section damper of 60”w X 36”h (1524mm x 914mm) at 5” (1.24kPa) w.g. would need to be built in 2 sections of 30”w X 36”h (762mm x 914mm).)

60"

48"

36"

24"

12"3 4 5 6 7 8 9 10 11 12 13 14 15

Blad

e Le

ngth

(inc

hes)

Maximum Design Total Static Pressure (inches w.g.)

BLADE DESIGN PRESSURE LIMITATIONSMAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

LeakagetestingwasconductedinaccordancewithAMCAStandard500-D-98.Holdingtorqueappliedwas5.2in.-lbs./sq.ft.onopposedbladedampersand7in.-lbs./sq.ft.onparallelbladedampersAMCAStandard500-D-98statesthatairleakageisbasedonoperationbetween50°F(10°C) and104°F(40°C). Alltestswereperformedwith120in.-lbs.inresultinginamaximumof120in.-lbs./ft²withthe12”x12”damper.The following sizes of TAMCO Series 1000 & 1000 SW dampers were tested:12" x 12" (305 mm x 305 mm), 24" x 24" (610 mm x 610 mm), 48" x 12" (1219 mm x 305 mm)12" x 48" (305 mm x 1219 mm), 36" x 36" (914 mm x 914 mm), 60" x 36" (1524 mm x 914 mm).

Pressure

Class

LEAKAGE, ft 3/min/ft 2 (l/s/m2) Required Rating Extended Ranges (Opt.)

1" / 0.25 kPa 4" / 1.0 kPa 8" / 2.0 kPa 12" / 3.0 kPa

1A 3 / 15.2 n/a n/a n/a

1 4 / 20.3 8 / 40.6 11 / 55.9 14 / 71.1

2 10 / 50.8 20 / 102 28 / 142 35 / 178

3 40 / 203 80 / 406 112 / 569 140 / 711

LEAKAGE RATING

1 in. w.g. 4 in. w.g. 8 in. w.g.Damper Width

12" (305mm) 1A 1 11

24" (610mm) 1A 1 11

36" (914mm) 1A 1 n/a

48" (1219mm) 1A 1 n/a

60" (1524mm) 1A 1 n/a

28

Page 34: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4" deep.

• Bladesareextrudedaluminum (6063T5) profiles.

• BladesealsareextrudedEPDM.Framesealsareextrudedsilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Leakagedoesnotexceed3cfm/ft.²(15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of twoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 1 0 0 0AIR-FOIL CONTROL DAMPER

4000 SERIESMULLION TYPE

CHANNEL FRAME

3000 SERIESMULLION TYPE

EXTERIOR FLANGE

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under

9 ft.² (.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in

height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• For open blade clearance in tight spaces, consider the Series 1400 − 4” wide air-foil blade option.

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

For additional information, refer to:• Series 1000 SWSpecification Sheet• Series 1500,1500SW,1000&1000SWPressureDrop• Series 1500,1500SW,1000&1000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines• Series 1400 −4"WideAir-FoilBladeControl Damper Specification Sheet• Series 1400 −4”WideAir-FoilBladeControl Damper Free Area Charts

29

Page 35: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080”(2.03mm)inthickness.Damperframeis4”deep.Aluminumframeisclearanodizedtoaminimumthicknessof0.7mil(18microns)deep.Frameisassembledusingtype316stainless steel screws.

• Extrudedaluminumbladesareanodizedtoaminimumthicknessof0.7mil(18microns) deep. Aluminum blade pivot rods areclearanodized.

• Bladeandframesealsareofextrudedsilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframeside.Allaluminumlinkagehardwarepartsareclearanodized.Allnon-aluminumlinkagehardwarepartsaretype316stainlesssteel,completewithcup-pointtrunnionscrewsforslip-proofgrip.Adjustablehexagondriverod,U-boltfastenerandretainingnutsaretype316stainlesssteel.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Leakagedoesnotexceed3cfm/ft.²(15.2l/s/m2)against1”(.25kPa)w.g. differential static pressure.

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Dampersaremadetosizerequiredwithoutblankingofffreearea.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of twoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 1 0 0 0 S WSALT WATER RESISTANCE AIR-FOIL CONTROL DAMPER

4000 SERIESMULLION TYPE

CHANNEL FRAME

3000 SERIESMULLION TYPE

EXTERIOR FLANGE

OPPOSED ACTION

PARALLEL ACTION

6"152.4mmfully open

4"101.6mm

1"25.4mm

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:• To reduce pressure drop, use “Flanged to Duct” type for sizes under 9 ft.²

(.83m2).• Suitable for operation in breathable air environments within stated

temperature range.• Dampers sized for duct openings exceeding 37½" (953mm) in height are

equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

• For open blade clearance in tight spaces, consider the Series 1400 SW− 4” wide air-foil blade option.

For additional information, refer to:• Series 1000 Specification Sheet• Series 1500,1500SW,1000&1000SWPressureDrop• Series 1500,1500SW,1000&1000SWFree Area Charts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines• Series 1400 SW−4"WideAir-FoilBladeControl Damper Specification Sheet• Series 1400 SW−4”WideAir-FoilBladeControl Damper Free Area Charts

30

Page 36: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

PRESSURE DROP

SER I ES 1500 , 1500 SW, 1000 , & 1000 SW

S E L E C T I O N T A B L E AREA FACTOR

Thetable(above)andthechart(below)areusedtofindthepressuredropthroughallTAMCOSeries1500,1500SW,1000&1000SWAir-FoilControlDampers.1) In the above table, select the area factor value recorded, where the duct width column and duct height line meet.2) In the chart below, enter the area factor obtained from above and the cfm for the application and read the pressure drop off where the “Area Factor” line and the “Volume Flow Rate” column meet. (Example: duct size 16”w x 36”h = .20 area factor (above table). Then, if cfm is 2000, pressure drop = .008” w.g. (chart below).)

S E L E C T I O N C H A R T PRESSURE DROP

PRESSURE LOSS,

INCHES w.g.

AREA

FA

CTO

R

0.010.020.040.070.10.150.20.30.40.50.60.70.80.91

1.21.52

2.534567

500.000025.00005.0001

.000175.00025.000375.0005.00075.001

.00125.0015.00175.002

.00225.0025.003

.00375.005

.00625.0075.01

.0125.015.0175

1000.0001.0002.0004.0007.001.0015.002.003.004.005.006.007.008.009.01.012.015.02.025.03.04.05.06.07

1500.000225.00045.0009

.001575.00225.003375.0045.00675.009

.01125.0135.01575.018

.02025.0225.027

.03375.045

.05625.0675.09

.1125.135.1575

2000.0004.0008.0016.0028.004.006.008.012.016.02.024.028.032.036.04.048.06.08.1.12.16.2.24.28

2500.000625.00125.0025

.004375.00625.009375.0125.01875.025

.03125.0375.04375

.05.05625.0625.075

.09375.125

.15625.1875.25

.3125.375.4375

3000.0009.0018.0036.0063.009.0135.018.027.036.045.054.063.072.081.09.108.135.18.225.27.36.45.54.63

4000.0016.0032.0064.0112.016.024.032.048.064.08.096.112.128.144.16.192.24.32.4.48.64.8.961.12

5000.0025.005,01

.0175.025.0375.05.075.1

.125.15.175.2

.225.25.3

.375.5

.625.751

1.251.51.75

6000.0036.0072.0144.0252.036.054.072.108144.18.216.252.288.324.36.432.54.72.9

1.081.441.82.162.52

8000.0064.0128.0256.0448.064.096.128.192.256.32.384.448.512.576.64.768.961.281.61.922.563.23.844.48

10000.01.02.04.07.1.15.2.3.4.5.6.7.8.91

1.21.52

2.534567

15000.0225.045.09

.1575.225.3375.45.675.9

1.1251.351.5751.8

2.0252.252.7

3.3754.5

5.6256.75

911.2513.515.75

20000.0408.16.28.4.6.81.21.62

2.42.83.23.64

4.868101216202428

25000.0625.125.25

.4375.625.93751.251.8752.5

3.1253.754.375

55.6256.257.5

9.37512.5

15.62518.75

2531.2537.543.75

30000.09.18.36.63.9

1.351.82.73.64.55.46.37.28.19

10.813.518

22.52736455463

40000.16.32.641.121.62.43.24.86.48

9.611.212.814.416

19.224324048648096112

50000.25.51

1.752.53.75

57.510

12.515

17.520

22.52530

37.550

62.575100125150175

VOLUME FLOW RATE (CFM)

AREA FACTOR TABLE

WIDTH (inches)

HEI

GH

T (inch

es)

12162024283236404448525660

123.2000

1.8000

1.1520

.8000

.5878

.4500

.3556

.2880

.2380

.2000

.1704

.1469

.1280

161.8000

1.0125

.6480

.4500

.3306

.2531

.2000

.1620

.1339

.1125

.0959

.0827

.0720

201.1520

.6480

.4147

.2880

.2116

.1620

.1280

.1037

.0857

.0720

.0613

.0529

.0461

24.8000

.4500

.2880

.0688

.0505

.0387

.0306

.0248

.0205

.0172

.0146

.0126

.0110

28.5878

.3306

.2116

.0505

.0371

.0284

.0224

.0182

.0150

.0126

.0108

.0093

.0081

32.4500

.2531

.1620

.0387

.0284

.0218

.0172

.0139

.0115

.0097

.0082

.0071

.0062

36.3556

.2000

.1280

.0306

.0224

.0172

.0222

.0180

.0149

.0125

.0107

.0092

.0080

40.2880

.1620

.1037

.0248

.0182

.0139

.0180

.0146

.0120

.0101

.0086

.0074

.0065

44.2380

.1339

.0857

.0205

.0150

.0115

.0149

.0120

.0100

.0084

.0071

.0061

.0054

48.2000

.1125

.0720

.0172

.0126

.0097

.0125

.0101

.0084

.0070

.0060

.0052

.0045

52.1704

.0959

.0613

.0146

.0108

.0082

.0107

.0086

.0071

.0060

.0051

.0044

.0038

56.1469

.0827

.0529

.0126

.0093

.0071

.0092

.0074

.0061

.0052

.0044

.0038

.0033

60.1280

.0720

.0461

.0110

.0081

.0062

.0080

.0065

.0054

.0045

.0038

.0033

.0029

Note: 1. Ratings are based on AMCA Standard 500, using Test Setup Apparatus Figure 5.3 (damper installed with duct upstream & downstream).2. Above Area Factor values are based on flanged-to-duct type installations. Pressure drop will be greater for installed in-duct type dampers. Call TAMCO Customer Service at

1-800-561-3449 for pressure drop calculations for installed in-duct type dampers.3. Dampers sized for duct openings exceeding 37½” (953 mm) in height are equipped with a stiffener bar at mid-height, which is reflected in the above chart.

31

Page 37: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

WIDTH (inches)HEI

GHT

(inch

es)

12 24 36 48 60 72 84 96 108 120 0.73 1.46 2.19 2.92 3.65 4.13 4.86 5.59 6.32 7.05 0.37 0.89 1.41 1.93 2.45 2.84 3.36 3.88 4.41 4.93 1.63 3.25 4.88 6.50 8.13 9.21 10.83 12.46 14.08 15.71 1.00 2.42 3.84 5.25 6.67 7.73 9.15 10.57 11.98 13.40 2.47 4.94 7.41 9.88 12.34 13.99 16.46 18.93 21.40 23.86 1.64 3.95 6.26 8.58 10.89 12.62 14.93 17.25 19.56 21.87 3.28 6.56 9.84 13.13 16.41 18.59 21.88 25.16 28.44 31.72 2.21 5.34 8.46 11.59 14.71 17.06 20.18 23.31 26.43 29.56 4.18 8.35 12.53 16.71 20.89 23.67 27.85 32.02 36.20 40.38 2.81 6.78 10.75 14.72 18.69 21.66 25.63 29.60 33.57 37.54 5.07 10.15 15.22 20.29 24.52 28.75 33.82 38.89 42.27 47.35 3.45 8.31 13.17 18.04 21.69 26.55 31.42 36.28 39.53 44.39 5.60 11.21 16.81 22.42 28.02 31.76 37.36 42.97 48.57 54.17 3.82 9.22 14.61 20.01 25.41 29.45 34.85 40.24 45.64 51.04 6.40 12.79 19.19 25.58 31.98 36.24 42.64 49.03 55.43 61.83 4.46 10.75 17.04 23.33 29.62 34.34 40.63 46.93 53.22 59.51 7.29 14.58 21.88 29.17 36.46 41.32 48.61 55.90 63.19 70.49 5.09 12.28 19.47 26.65 33.84 39.23 46.42 53.61 60.79 67.98 8.19 16.38 24.56 32.75 40.94 46.40 54.58 62.77 70.96 79.15 5.65 13.63 21.61 29.59 37.57 43.55 51.53 59.51 67.49 75.47

12

24

36

48

60

72

84

96

108

120

M E T E R S S Q U A R E D 305 610 915 1220 1525 1829 2134 2439 2744 3048 0.07 0.14 0.20 0.27 0.34 0.38 0.45 0.52 0.59 0.65 0.03 0.08 0.13 0.18 0.23 0.26 0.31 0.36 0.41 0.46 0.15 0.30 0.45 0.60 0.75 0.86 1.01 1.16 1.31 1.46 0.09 0.22 0.36 0.49 0.62 0.72 0.85 0.98 1.11 1.24 0.23 0.46 0.69 0.92 1.15 1.30 1.53 1.76 1.99 2.22 0.15 0.37 0.58 0.80 1.01 1.17 1.39 1.60 1.82 2.03 0.30 0.61 0.91 1.22 1.52 1.73 2.03 2.34 2.64 2.95 0.21 0.50 0.79 1.08 1.37 1.58 1.88 2.17 2.46 2.75 0.39 0.78 1.16 1.55 1.94 2.20 2.59 2.98 3.36 3.75 0.26 0.63 1.00 1.37 1.74 2.01 2.38 2.75 3.12 3.49 0.47 0.94 1.41 1.89 2.28 2.67 3.14 3.61 3.93 4.40 0.32 0.77 1.22 1.68 2.01 2.47 2.92 3.3.7 3.67 4.12 0.52 1.04 1.56 2.08 2.60 2.95 3.47 3.99 4.51 5.03 0.36 0.86 1.36 1.86 2.36 2.74 3.24 3.74 4.24 4.74 0.59 1.19 1.78 2.38 2.97 3.37 3.96 4.56 5.15 5.74 0.41 1.00 1.58 2.17 2.75 3.19 3.78 4.36 4.94 5.53 0.68 1.35 2.03 2.71 3.39 3.84 4.52 5.19 5.87 6.55 0.47 1.14 1.81 2.48 3.14 3.64 4.31 4.98 5.65 6.32 0.76 1.52 2.28 3.04 3.80 4.31 5.07 5.83 6.59 7.35 0.53 1.27 2.01 2.75 3.49 4.05 4.79 5.53 6.27 7.01

305

610

915

1220

1525

1829

2134

2439

2744

3048

WIDTH (mm)

HEI

GHT

(mm

)

F E E T S Q U A R E D

P E R C E N T A G E 12 24 36 48 60 72 84 96 108 120 72.92 72.92 72.92 72.92 72.92 68.87 69.44 69.88 70.22 70.49 36.89 44.49 47.02 48.29 49.05 47.38 48.05 48.56 48.95 49.26 81.25 81.25 81.25 81.25 81.25 76.74 77.38 77.86 78.24 78.54 50.17 60.50 63.95 65.67 66.70 64.44 65.35 66.04 66.57 67.00 82.29 82.29 82.29 82.29 82.29 77.72 78.37 78.86 79.24 79.55 54.60 65.84 69.59 71.46 72.59 70.12 71.12 71.86 72.44 72.91 82.03 82.03 82.03 82.03 82.03 77.47 78.13 78.61 78.99 79.30 55.34 66.73 70.53 72.43 73.57 71.07 72.08 72.84 73.42 73.89 83.54 83.54 83.54 83.54 81.73 78.90 79.56 80.06 80.45 80.76 56.22 67.80 71.66 73.59 74.74 72.21 73.23 74.00 74.60 75.08 84.55 84.55 84.55 84.55 84.55 79.85 80.52 81.03 78.29 78.91 57.43 69.25 73.19 75.16 72.29 73.76 74.80 75.59 73.19 73.98 80.06 80.06 80.06 80.06 80.06 75.61 76.25 76.72 77.09 77.39 54.60 65.84 69.59 71.46 72.59 70.12 71.12 71.86 72.44 72.91 79.95 79.95 79.95 79.95 79.95 75.51 76.14 76.62 76.99 77.28 55.71 67.18 71.00 72.91 74.06 71.55 72.56 73.32 73.91 74.39 81.02 81.02 81.02 81.02 81.02 76.52 77.16 77.64 78.02 78.32 56.57 68.21 72.10 74.04 75.20 72.65 73.68 74.45 75.05 75.54 81.88 81.88 81.88 81.88 81.88 77.33 77.98 78.46 78.84 79.15 56.52 68.16 72.03 73.97 75.14 72.59 73.62 74.39 74.99 75.47

12

24

36

48

60

72

84

96

108

120

HEI

GHT

(inch

es)

WIDTH (inches)

FREE AREA CHARTS

• Toreducepressuredrop,use"FlangedtoDuct" type for sizes under 9 ft.² (.83m2).

• Damperssizedforductopeningsexceeding37½" (953mm) in height are equipped with

a stiffener bar at mid-height, to strengthen and maintain air leakage tolerances.

NOTE:

FLANGED TO DUCT

INSTALLED IN DUCT

SER I ES 1500 , 1500 SW, 1000 , & 1000 SW

32

Page 38: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

L OW L E A K AG E / M A I N T E N AN C E - F R E E4” BLADE AIR-FOIL CONTROL

S E R I E S 1 4 0 0

33

• Dampersareconstructedwith4”blades.• Whendamperbladesareinthefullyopenposition,bladesdonotexceedbeyondthe4”frame.

S P A C E - S A V I N G

NARROWER PROFILE

Page 39: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

F E E T S Q U A R E D 12

24

36

48

60

WIDTH (inches)

HEI

GHT

(inch

es)

12 24 36 48 60 72 84 96 108 120 0.68 1.35 2.03 2.71 3.39 3.84 4.51 5.19 5.87 6.55 0..37 0.89 1.41 1.93 2.45 2.84 3.36 3.89 4.41 4.93 1.47 2.94 4.41 5.88 7.34 8.32 9.79 11.26 12.73 14.20 0.93 2.24 3.56 4.87 6.18 7.16 8.48 9.79 11.10 12.41 2.23 4.46 6.69 8.92 11.15 12.63 14.86 17.09 19.32 21.55 1.53 3.68 5.84 8.00 10.15 11.77 13.93 16.08 18.24 20.40 3.07 6.15 9.22 12.29 15.37 17.41 20.49 23.56 26.63 29.71 2.03 4.89 7.76 10.62 13.49 15.64 18.50 21.37 24.23 27.09 3.87 7.73 11.59 15.46 19.32 21.90 25.76 29.63 33.49 37.36 2.59 6.25 9.90 13.56 17.22 19.96 23.61 27.27 30.93 34.58

M E T E R S S Q U A R E D 305 610 915 1220 1525 1829 2134 2439 2744 3048 0.06 0.13 0.19 0.25 0.31 0.36 0.42 0.48 0.55 0.61 0.03 0.08 0.13 0.18 0.23 0.26 0.31 0.36 0.41 0.46 0.14 0.27 0.41 0.55 0.68 0.77 0.91 1.05 1.18 1.32 0.09 0.21 0.33 0.45 0.57 0.67 0.79 0.91 1.03 1.15 0.21 0.41 0.62 0.83 1.04 1.17 1.38 1.59 1.79 2.00 0.14 0.34 0.54 0.74 0.94 1.09 1.29 1.49 1.69 1.89 0.29 0.57 0.86 1.14 1.43 1.62 1.90 2.19 2.47 2.76 0.19 0.45 0.72 0.99 1.25 1.45 1.72 1.98 2.25 2.52 0.36 0.72 1.08 1.44 1.80 2.03 2.39 2.75 3.11 3.47 0.24 0.58 0.92 1.26 1.60 1.85 2.19 2.53 2.87 3.21

WIDTH (mm)

HEI

GHT

(mm

) 305

610

915

1220

1525

P E R C E N T A G E

HEI

GHT

(inch

es)

WIDTH (inches)

12

24

36

48

60

12 24 36 48 60 72 84 96 108 120 67.71 67.71 67.71 67.71 67.71 63.95 64.88 64.89 65.20 65.45 36.89 44.49 47.02 48.29 49.05 47.38 48.05 48.56 48.95 49.26 73.44 73.44 73.44 73.44 73.44 69.36 69.94 70.38 70.72 70.99 46.48 56.05 59.24 60.84 61.80 59.70 60.55 61.18 61.68 62.07 74.31 74.31 74.31 74.31 74.31 70.18 70.77 71.21 71.55 71.83 50.91 61.39 64.89 66.63 67.68 65.39 66.31 67.01 67.55 67.98 76.82 76.82 76.82 76.82 76.82 72.55 73.16 73.62 73.98 74.26 50.73 61.17 64.65 66.39 67.44 65.15 66.07 66.77 67.30 67.74 77.29 77.29 77.29 77.29 77.29 73.00 73.61 74.07 74.43 74.72 51.80 62.46 66.02 67.79 68.86 66.52 67.47 68.17 68.72 69.16

FREE AREA CHARTS

FLANGED TO DUCT

INSTALLED IN DUCT

SER I ES 1400 & 1400 SW

• Toreducepressuredrop,use"FlangedtoDuct" type for sizes under 9 ft.² (.83m2).

• Damperssizedforductopeningsexceeding37½" (953mm) in height are equipped with

a stiffener bar at mid-height, to strengthen and maintain air leakage tolerances.

NOTE:

34

Page 40: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080”(2.03mm)inthickness.Damperframeis4”deep.

• Bladesareextrudedaluminum(6063T5)profiles.Bladesare4"wideanddonotextendbeyondtheframewheninthe full open position.

• BladesealsareextrudedEPDM.Framesealsaresilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16”(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframesideandconstructedofaluminumandcorrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Dampersaremadetosizerequired.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with eachshipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.ca supersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist oftwoormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 1 4 0 0 C O N T R O L D A M P E R4” WIDE AIR-FOIL BLADE

OPPOSED ACTION

PARALLEL ACTION

4"101.6mm

1"25.4mm

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:

• To reduce pressure drop, use “Flanged to Duct” type for sizes under 9 ft.² (.83m2).

• Suitable for operation in breathable air environments within stated temperature range.

• Dampers sized for duct openings exceeding 37 ½" (953mm) in height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

For additional information, refer to:

• Series1400SWSpecificationSheet• Series1400&1400SWFreeAreaCharts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

35

Page 41: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080" (2.03mm) inthickness.Damperframeis4" deep. Aluminumframeisclearanodizedtoaminimumthicknessof0.7mil(18microns)deep.Frameisassembledusingtype316stainless steel screws.

• Extrudedaluminumbladesareanodizedtoaminimumthicknessof0.7mil(18microns) deep. Aluminum blade pivot rods are clearanodized.

• Bladesareextrudedaluminum (6063T5) profiles.Bladesare4"wideanddonotextendbeyondtheframewheninthefullopen position.

• Bladeandframesealsareofextrudedsilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• BearingsarecomposedofaCelconinnerbearingfixedtoa7/16"(11.11mm) aluminumhexagonbladepin,rotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledintheframeside.Allaluminumlinkagehardwarepartsareclearanodized.Allnon-aluminumlinkagehardwarepartsaretype316stainlesssteel,completewithcup-pointtrunnionscrewsforslip-proofgrip.Adjustablehexagondriverod,U-boltfastenerandretainingnutsaretype316stainlesssteel.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Dampersareavailablewitheitheropposedbladeactionorparallelbladeaction.

• Dampersaremadetosizerequired.

• Dampersareavailableintwomountingtypes:i.e.,"InstalledinDuct"or"FlangedtoDuct".

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of two ormoresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

S E R I E S 1 4 0 0 S W C O N T R O L D A M P E R4" WIDE AIR-FOIL BLADE / SALT WATER RESISTANCE

OPPOSED ACTION

PARALLEL ACTION

4"101.6mm

1"25.4mm

"INSTALLED IN DUCT" TYPE½" deducted for clearance from width & height dimensions unless otherwise specified

"FLANGED TO DUCT" TYPE2" added to duct width & height dimensions

Note:

• To reduce pressure drop, use “Flanged to Duct” type for sizes under 9 ft.² (.83m2).

• Suitable for operation in breathable air environments within stated temperature range.

• Dampers sized for duct openings exceeding 37 ½" (953mm) in height are equipped with a stiffener bar at mid-height to strengthen and maintain air leakage tolerances.

For additional information, refer to:

• Series 1400 Specification Sheet• Series1400&1400SWFreeAreaCharts• Aluminum Standard Configurations• TAMCO Aluminum Damper Torque Requirements• Multiple-Section Horizontal Jack Shafts• Configurations Using Vertical Jack Shafts • Multiple-Section Damper Jumpers • Square-to-Round Transition Option• TAMCO Aluminum Damper Installation Guidelines

36

Page 42: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

• TAMCObearingsconsistofpolycarbonateandacetalcopolymer(Celcon) engineered thermal plastic resins.• Dualbearingsystemisself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotallymaintenance-freeperformance.

• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• Tensileimpactstrengthofcelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'sbearing-to-bearingarrangementeliminatesactionbetweenmetal-to-metalandmetal-to-plastic

riding surfaces. (Metal-on-metal steel, bronze or oil-lite bearings and metal-on-plastic nylon bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

• TAMCO"DualBearingSystem"hasaservicelifeof20yearsplus. (Replacement TAMCO bearings, which fit TAMCO dampers exclusively, have not been required in over 35 years, when dampers

have been installed according to manufacturer's guidelines.)

D E P E N D A B L E "DUAL BEARING SYSTEM"

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hexagondesignfeatureoflinkageandpivotelementsallowforflat-on-flatpressfitsthateliminateplayandwear.

•Hardalloy aluminum (6005T5) linkage crank armandpivotpinaredoublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005T5) linkage rod connects thecrankarms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

I N T E R - D E C K

SOLID CONNECTION

•Connectionsbetweendecksarehardalloyaluminum(6005T5)rods.•AluminumrodisstampedintoonedeckandU-boltedtotheoppositedeck.•Nointernalmechanismtoloosen,fail,oromit.•Transmissionoftorque,orstroke,isdirectandwithoutlosses.•Connectionsbetweendeckswillnotdevelopanywearorplay.

DECK 1

DECK 2

Viewofuninterruptedlinkagebetweendecks

T W O - D E C KMULTIZONE DAMPER

S E R I E S 1000 MZ

37

Page 43: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

P U R P O S E - B U I L T

DESIGN•Bladesarecoredtoappropriateanglestoensure90°operationbetween

decks.•Internalzonedividersaredesignedtoacceptductconnections.•Two-DeckMultizonesareavailablewithdrivesoneithertheleft-handor

theright-handside.(Choice of right- or left-hand drive must be made at the time the order is placed.)

•Increasedfreeareaachievedbyreducingthewidthofthecentreframesandbyintroductionoflow-profile

internalzonedividers.

Splittersbetweenzones

NO STANDARD CONFIGURATIONS ARE AVAILABLE FOR SERIES 1000 MZ. CALL TAMCO CUSTOMER SERVICE FOR CONFIGURATIONS AND DRAWINGS. 1-800-561-3449

C U S T O M

CHOICES•Individualzonesizingtomeetcustomerrequirementsachievedwiththeuseof6",5",&4"bladedepths.

•Individualzonescanbebuiltwithparalleloropposedbladeactionwithinthesamemultizonedamper.

•Decksaremanufacturedtocustomer-specifieddimensions.•Deckscanbespacedapartfromeachotherandlinkagebetweendeckswillbelengthenedaccordingly.

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

T O T A L A I R C O N T R O L

PERFORMANCE•TAMCO’sdesignandmaterialmatrixprovidesfordurableand dependable components.•TAMCO’sexactingqualitycontrolandsoundworkmanshipensureproductintegrity.

•TAMCOprovidesandhasavailableinstallationguidelines,technicalsupportandatoll-freecustomer service number.

(Each and every TAMCO damper displays the 1-800 customer service number.)

•TAMCOproductsandpersonnelareyourguaranteeoftotalair control performance.

Right-hand drive shown.

38

Page 44: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 1 0 0 0 M Z

TWO-DECK MULTIZONE DAMPER

Available only as"FLANGED TO DUCT" TYPE

• Extrudedaluminum(6063T5)damperframeisnotlessthan.080”(2.03mm)inthickness.Damperframeis4”(101.6mm) deep.

• Thereisa1"(25.4mm) frame on all sides of each deck.

• Bladesare extrudedaluminum(6063T5) profiles.

• Internalzonedividers(splitters) areextrudedaluminum(6063T6)profiles.

• BladegasketsareextrudedEPDM.FramesealsareextrudedTPEthermoplastic.Gasketsaresecuredinanintegralslotwithinthealuminumextrusions.

• Bearingsarecomposed of a Celconinnerbearingfixedtoa7/16”(11.11mm)aluminumhexagonbladepinrotatingwithinapolycarbonateouterbearinginsertedintheframe,resultinginnometal-to-metalormetal-to-plasticcontact.

• Linkagehardwareisinstalledinthe frame side and constructed of aluminum and corrosion-resistant,zinc-platedsteel,completewithcup-pointtrunnionscrewsforaslip-proofgrip.

• Bladeaxles consist of a 7/16"hexagonsolidaluminumbar.Driveshaftis7/16"hexagon,zinc-platedsteel.

• Bladesarelinkedbetweendeckswitha7/16"extrudedaluminum(6063T6)hexagonrod.

• Dampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C)and212°F(100°C).

• Airleakagethrougha24”x24”(610mmx610mm)damperdoesnotexceed3 cfm/ft.²(24 l/s/m2) against 1”(0.25kPa)w.g. differential static pressure at standard air.

• Dampersaremadetosizerequiredwithoutblankingoffthe free area.

• Allsizesareinsideframedimensions.

• Theminimumsizewithineachzoneis4½"(108mm)perpendiculartotheblades.Theminimumsizewithineachdeckis6"(152mm), parallel to the blades.

• Themaximumoverallinsidedimension,perpendiculartotheblades,is120"(3048mm).

• Themaximumsizewithineachzoneis75"(1905mm),perpendiculartotheblades,whenallthebladesinthezonearelinked.Themaximumsizewithineachdeckis36"(914mm), parallel to the blades.

• Themaximumspacingbetweendecksis24"(610mm).Spacingbetweendecksismanufacturedin2"(51mm)increments. Allmultizonedamperswithspacingbetweendecksthatexceeds2"(51mm)arebuiltwitha16ga.galvanizedsteelsheetfastenedwith#8,½"tekscrews.

• Dampersareavailableinonly“FlangedtoDuct”mountingtype.

• Installation of dampers must be in accordance with current manufacturer’s installation guidelines provided with each shipmentofTAMCOdampers.(NotethatalltechnicalinformationavailableonTAMCO’swebsiteatwww.tamco.casupersedes and takes precedence over all information contained within the printed catalog.)

• Intermediate or tubular steel structural support is required to resist applied pressure loads for dampers that consist of two or moresectionsinbothheightandwidth.(SeeTAMCOAluminumDamperInstallationGuidelines.)

Note:• Suitable for operation in breathable air environments within

stated temperature range.• Also available as Series 1001 MZ, One-Deck Multizone.

For additional information, refer to:• Series1000MZDimensionalParameters• Series1000SpecificationSheet• Series1500,1500SW,1000&1000SWPressureDrop• Series 1500,1500SW,1000&1000SWFree Area Charts• TAMCOAluminumDamperTorqueRequirements• TAMCOAluminumDamperInstallationGuidelines

39

Page 45: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S E R I E S 1 0 0 0 M Z

DIMENSIONAL PARAMETERS

FRONT / TOP END UP / RIGHT HAND When the labels on the blades are viewed right side up, the damper orientation is Front/Top end up. When viewed as Front/Top end up, right hand (RH) has drive rods on the right. Left hand (LH) has drive rods on the left.

When the left blades are shut, the right blades are open.When the right blades are shut, the left blades are open.

RIGHT HAND

RH

CCWROTATION TO OPEN RIGHT SIDEROTATION TO CLOSE LEFT SIDE

Service 1-800-561-3449

SPLITTERS

CWROTATION TO OPEN LEFT SIDE

ROTATION TO CLOSE RIGHT SIDE

LEFT HAND

LHService 1-800-561-3449

SPLITTERS

TWO-DECK MULTIZONE DAMPERMINIMUM & MAXIMUM UNIT SIZES: MINIMUM: 14” MAXIMUM: 96” (MAXIMUM dimension includes 24” maximum spacing between decks.)

MINIMUM: 4¼”MAXIMUM: 120”

(Dimensions refer to inside measurements of external frame.)

MINIMUM & MAXIMUM DECK SIZES: MINIMUM: 6”MAXIMUM: 36”(Dimensions refer to inside measurements of individual deck frames.)

MINIMUM & MAXIMUM ZONE SIZES:MINIMUM: 4¼”MAXIMUM: 75”(Dimensions refer to inside measurements of individual internal zone dividers or zone frames.)

MINIMUM & MAXIMUM SPACING BETWEEN DECKS:MINIMUM: 2”MAXIMUM: 24”(Dimensions are measured from the inside edge to the opposite inside edge of the centre frames separating decks.)

A

B

D

C

A

E

RIGHT HAND

RH

Serv

ice 1

-800

-561

-344

9

1”

A

B

C

D

C

E

40

Page 46: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

•Dampersareassembledusingslip-prooflinkagecomponentsthatkeepbladesalignedasperfactoryadjustment.

•Hardalloy aluminum (6005T6) linkage crank arm and pivot pin are doublysecuredbypincer-actionandfastener.

•Largediameter(11/32" / 8.73mm)hardalloyaluminum(6005-T6C) linkage rod connects the crank arms,whichallowsforapenetratinggripbythecup-point fastener.

(Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

•Trunnionsarezinc-plated to provideahard,smoothandlong-lasting rotating surface.

M A I N T E N A N C E - F R E E

PERFORMANCE ACHIEVED

A L U M I N U M

STRENGTH AND DURABILITY•Aluminumdampersprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

•Aluminumextrusionsallowforintricatedesignfeaturesnotpossiblewithrollorbrakeformedgalvanizedsteel.

•Aluminumconstructionallowsforadditionalstrengthbyextrudinginternal supports and thicker radii.

•Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Standard damper is produced with a mill finish.)

• Linkagesystemconsistsofhardalloyaluminum(6005-T6C)crankarmsfastenedtozinc-platedsteelpivotrodsandisdoublysecuredwithinachannelrunningalongthetopoftheblade.

• BearingsystemiscomposedofCelconbearingsrotatingonzinc-plated,½”steelpivotpoints.• Celcon bearings areself-sealing,self-lubricating,andnon-absorbent,whichresultsinatotally maintenance-freeperformance.• Bearingmaterialsmeetorexceedtensilestrengthof8,800psiandflexuralstrengthof12,000psi.• TensileimpactstrengthofCelconis70ft.-lb./in.²and145ft.-lb./in.²forpolycarbonate.• TAMCO'slinkagesystemeliminatesactionbetweenmetal-to-metalridingsurfaces. (Metal-on-metal steel, bronze and oil-lite

bearings have traditionally been one of the weakest links in damper operation, requiring regular lubrication or eventual replacement.)

D E P E N D A B L E "LINKAGE SYSTEM"

L O W

LEAKAGE RATE• Damperissuppliedwithextrudedsiliconebladeandsideseals.

•Leakagethrougha24”x24”(610mmx610mm) TAMCO BackDraftDamperat1”(.25kPa) w.g. pressure difference to be not greater than 20 cfm/ft.² (101.2 l/s/m2).

•Servicetemperatureofthedamperis212°F(100°C)to-40°F(-40°C).

•Silicone’ssuperiordynamicfatigueresistanceensuresprolongedsealinglongevity,plusphenomenalresistancetoweathering,compressionset,andheat.

•Siliconesealshaveanapproximateservicelifeof30years.

• Series7000BackDraftDampersallow operation in vertical and horizontal-uppositions.

LOWLEAKAGE / LONG-TERM, DEPENDABLEBACK DRAFT DAMPERS

S E R I E S 7 0 0 0

41

Page 47: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 7 0 0 0 W TWEIGHTED

BACK DRAFT DAMPER

S E R I E S 7 0 0 0 C WCOUNTERWEIGHTED

BACK DRAFT DAMPER

• Eachbladeismanufacturedwithamountingholetoreceiveafront-mounted mechanical weight.

• Weightsaresupplied,sothattherequiredresistancetotheopeningofthebladeagainstairflowcanbeachieved.

• Series7000WTWeightedBackDraftDampersallowoperationinverticalandhorizontal-uppositions.

• Counterweightsarefullyadjustableandcanbesettorelieveairpressuredifferentialslessthan.01”w.g.

• Counterweightsarethreadedandallowadjustmentstobemadewithonlyonetool.

• Bracketsareslottedtoallowprecisionslideadjustmentoftheweights.

• Bracketsareaffixedtobladesusing¼-20x 3/8”socketheadcapscrewswithcup-points.

• Series7000CWCounterweightedBackDraftDampersallowoperationinvertical,horizontal-upandhorizontal-downpositions.

T O T A L

PERFORMANCE

•TAMCO’sdesignandmaterialmatrixprovidesfordurableanddependablecomponents.

•TAMCO’sexactingqualitycontrolandsoundworkmanshipensureproductintegrity.

•TAMCOprovidesinstallationguidelines,technicalsupportandatoll-freecustomer service number. (Each and every TAMCO damper displays the 1-800 customer service number.)

•TAMCOproductsandpersonnelareyourguaranteeoftotalperformance.

42

Page 48: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)backdraftdamperframeisnotlessthan.060" (1.52mm) inthickness.Frameis2.5"(63.5mm) deep.

• Bladesareextrudedaluminum(6063T5) profilesandnotlessthan.060" (1.52mm) in thickness.

• Bladeandsidesealsareextrudedsilicone.Sealsaresecuredinintegralslotswithinthealuminumextrusions.

• BearingsystemiscomposedofCelconbearingsrotatingonzinc-plated½"(12.7mm) steel pivot points.

• Linkagesystemconsistsofhardalloyaluminum(6005T6)crankarmsfastenedtozinc-platedsteelpivotrodsanddoublysecuredwithinchannelrunningalongtopofblade.Largediameter11/32"(8.73mm)hardalloyaluminum(6065-T6C) linkage rod connects the crankarmsbymeansofazinc-platedsteeltrunnion.

• Cup-pointtrunnionscrewallowsforapenetratinggripofthelinkagerod. (Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

• Trunnionsarezinc-platedtoprovideahard,smoothandlong-lastingrotatingsurface.

• Backdraftdampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Airleakagethrougha24"x24"(610mmx610mm)backdraftdamperdoesnotexceed20cfm/ft.²(101.2l/s/m²) against 1"(.25kPa) w.g. differential static pressure at standard air.

• Backdraftdampersaremadetosizerequired. Minimumsectionsize:6"widex6"high(152mmx152mm) Maximumsectionsize:36"widex144"high(914mmx3658mm)(Mullion breaks will be used when damper height exceeds 48 inches.)

Backdraftdamperswithdimensionsgreaterthanmaximumsectionsizewillbemanufacturedinmultiplesections.Multiplesectionsarenotinterlinkedorconnected.Toinstall,eachsectionmustbeindividuallyfastenedtoastructuralframepreparedonsite.

• Availableinthreemountingtypes:"RearFlange","InDuct",or"FrontFlange".

S E R I E S 7 0 0 0B A C K D R A F T D A M P E R

Note:• Suitableforoperationinbreathableairenvironmentswithinstated

temperature range.• Forhorizontal/downmounting,specifyTAMCOSeries7000CW

Counterweighted Back Draft damper.• ¼" is deducted from the opening dimensions to allow for clearance on

mounting types Rear Flange, In Duct, Front Flange.• ¼" clearance deducted from Rear Flange and Front Flange mounting types

affects effective flange.

For additional information, refer to:• Series 7000 WT Specification Sheet• Series 7000 CW Specification Sheet

2.5"63.50 mm

fully open

5"127 mm

1 7/8"47.6 mm 5/8"

15.9 mm

5/8"15.9 mm

FrontFlange

In DuctRearFlange

Vertical Mount / Air Flow Horizontal

Horizontal Mount /Air Flow Up

43

Page 49: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

DAMPER WIDTH

Leakage at 1" w.g.Operational Data

Velocity (fpm) ∆ P in. w.g.

cfm / sq. ft. Blades begin to open Blades fully open Blades begin to

open Blades fully open

36" (914mm) 15.010 500 .03 .1324" (610mm) 20.0

12" (305mm) 40.0Series 7000 Test Data:Alltestswereconductedona24"x24"(610mmx610mm)rearflangemounttypebackdraftdamper.Thedatarepresenttheperformanceofthestatedsizeonlyandcannotbetransferreddirectlytoothersizes.Thisdataismeantonlyasanindicatorofthepressuresandvelocitiesneededforallthesizesavailable.

S E R I E S 7 0 0 0B A C K D R A F T D A M P E R

PRESSURE DROP

Airvelocityinfeetandmetersperminutethroughfacearea.TestedperAMCAStandard500,Figure5.5,ductworkupstreamanddownstream.

BLADE L IMITATIONS

Series7000BackDraftDampersthatexceedthemaximumdesignpressureorvelocityduetobladelengthmaybeusedbyreducingthewidthofthebackdraftdampersection(s)andincreasingthenumberofsectionsperdampertomaintainablade

lengthcompatiblewiththestatedsystempressureorvelocity.

Example: 1 section Series 7000 Back Draft Damper of 36"w x 36"h @ 3000 fpm would need to be built in 2 sections of 18"w x 36"h.

36"

30"

24"

18"

12"2500 2750 3000 3250 3500

LEN

GTH

OF

BLA

DE

(inch

es)

SYSTEM VELOCITY (fpm)

MAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

36"

30"

24"

18"

12"4.0 4.5 5.0 5.5 6.0

LEN

GTH

OF

BLA

DE

(inch

es)

PRESSURE (in. w.g.)

MAX. BLADE LENGTH vs. MAX. BACK PRESSURE (in. w.g.)

Pres

sure

Dro

p (in

ches

w.g

.)(in

take

mod

e)

VELOCITY VS. PRESSURE DROP10.0

1.0

0.1

0.01100 1,000 10,000

24" x 24"(610mm x 610mm)

Face Velocity (ft./min.) AMCA Figure 5.5

44

Page 50: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)weightedbackdraftdamperframeisnotlessthan.060" (1.52mm) inthickness.Frameis2.5"(63.5mm) deep.

• Bladesareextrudedaluminum (6063T5) profilesandnotlessthan.060"(1.52mm) in thickness.

• Eachbladeismanufacturedwithamountingholetoreceiveafront-mountedmechanicalweight.Weightsaresupplied,sothattherequiredresistancetotheopeningofthebladeagainstairflowcanbeachieved.

(To facilitate opening of blades, refer to the Series 7000 CW Specifications. The Series 7000 CW is an adjustable, counterweighted back draft damper designed to allow opening at lower pressures and air flow velocities.)

• Bladeandsidesealsareextrudedsilicone.Sealsaresecuredinintegralslotswithinthealuminumextrusions.

• BearingsystemiscomposedofCelconbearingsrotatingonzinc-plated½"(12.7mm) steel pivot points.

• Linkagesystemconsistsofhardalloyaluminum(6005T6)crankarmsfastenedtozinc-platedsteelpivotrodsanddoublysecuredwithinchannelrunningalongtopofblade.Largediameter11/32"(8.73mm)hardalloyaluminum(6065-T6C) linkage rod connects the crank arms bymeansofazinc-platedsteeltrunnion.

• Cup-pointtrunnionscrewallowsforapenetratinggripofthelinkagerod. (Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

• Trunnionsarezinc-platedtoprovideahard,smoothandlong-lastingrotatingsurface.

• Weightedbackdraftdampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C)and212°F(100°C).

• Airleakagethrougha24"x24"(610mmx610mm)weightedbackdraftdamperdoesnotexceed20cfm/ft.²(101.2l/s/m²) against1"(.25kPa) w.g. differential static pressure at standard air.

• Weightedbackdraftdampersaremadetosizerequired. Minimumsectionsize:6”widex6”high(152mmx152mm) Maximumsectionsize:36”widex144”high(914mmx3658mm)(Mullion breaks will be used when damper height exceeds 48 inches.)

Weightedbackdraftdamperswithdimensionsgreaterthanmaximumsectionsizewillbemanufacturedinmultiplesections.Multiplesectionsarenotinterlinkedorconnected.Toinstall,eachsectionmustbeindividuallyfastenedtoastructuralframepreparedonsite.

• Availableinthreemountingtypes:"RearFlange","InDuct",or"FrontFlange".

S E R I E S 7 0 0 0 W TWEIGHTED BACK DRAFT DAMPER

Note:• Suitableforoperationinbreathableairenvironmentswithinstated

temperature range.• Forhorizontal/downmounting,specifyTAMCOSeries7000CW

Counterweighted BackDraft Damper.• ¼" is deducted from the opening dimensions to allow for clearance on

mounting types Rear Flange, In Duct, Front Flange.• ¼" clearance deducted from Rear Flange and Front Flange mounting

types affects effective flange.

For additional information, refer to:• Series 7000 Specification Sheet• Series7000CWSpecificationSheet

2.5"63.50 mm

fully open

5"127 mm

1 7/8"47.6 mm

5/8"15.9 mm

5/8"15.9 mm

FrontFlange

In DuctRearFlange

Vertical Mount / Air Flow Horizontal

Horizontal Mount /Air Flow Up

45

Page 51: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

DAMPER WIDTH

Leakage at 1" w.g.cfm / sq. ft.

36" (914mm) 15.024" (610mm) 17.512" (305mm) 25.0

Series 7000 WT Test Data:Alltestswereconductedona24"x24"(610mmx610mm)rearflangemounttypeweightedbackdraftdamper.Thedatarepresenttheperformanceofthestatedsizeonlyandcannotbetransferreddirectlytoothersizes.Thisdataismeantonlyasanindicatorofthepressuresandvelocitiesneededforallthesizesavailable.

PRESSURE DROP

Airvelocityinfeetandmetersperminutethroughfacearea.TestedperAMCAStandard500,Figure5.5,ductworkupstreamanddownstream.

BLADE L IMITATIONS

Series7000WTWeightedBackDraftDampersthatexceedthemaximumdesignpressureorvelocityduetobladelengthmaybeusedbyreducingthewidthofthebackdraftdampersection(s)andincreasingthenumberofsectionsperdampertomaintain

abladelengthcompatiblewiththestatedsystempressureorvelocity.

Example: 1 section Series 7000 WT Weighted Back Draft Damper of 36”w x 36”h @ 3000 fpm would need to be built in 2 sections of 18”w x 36”h.

36"

30"

24"

18"

12"2500 2750 3000 3250 3500

LEN

GTH

OF

BLA

DE

(inch

es)

SYSTEM VELOCITY (fpm)

MAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

36"

30"

24"

18"

12"4.0 4.5 5.0 5.5 6.0

LEN

GTH

OF

BLA

DE

(inch

es)

PRESSURE (in. w.g.)

MAX. BLADE LENGTH vs. MAX. BACK PRESSURE (in. w.g.)

Pres

sure

Dro

p (in

ches

w.g

.)(in

take

mod

e)

VELOCITY VS. PRESSURE DROP10.0

1.0

0.1

0.01100 1,000 10,000

24" x 24"(610mm x 610mm)

Face Velocity (ft./min.) AMCA Figure 5.5

S E R I E S 7 0 0 0 W TW E I G H T E D B A C K D R A F T D A M P E R

Static Pressure and Face Velocity to Open Damper:Weightsarefullyadjustablesothattherequiredresistancetotheopeningofthebladeagainstairflowcanbeachieved.

46

Page 52: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)counterweightedbackdraftdamperframeisnotlessthan.060" (1.52mm) inthickness.Frameis2.5"(63.5mm) deep.

• Bladesareextrudedaluminum(6063T5) profilesandnotlessthan.060" (1.52mm) in thickness.

• Aluminum(6061T6)counterbalanceweightsaremountedoneachblade.Counterweightsarefullyadjustableandcanbesettorelieveairpressuredifferentialslessthan.01”w.g.

(If resistance to the opening of blades against air flow is required, refer to the Series 7000 WT Specifications. The Series 7000 WT is an adjustable, weighted back draft damper designed to resist opening until a desired static pressure is achieved.)

• Bladeandsidesealsareextrudedsilicone.Sealsaresecuredinintegralslotswithinthealuminumextrusions.

• BearingsystemiscomposedofCelconbearingsrotatingonzinc-plated½"(12.7mm) steel pivot points.

• Linkagesystemconsistsofhardalloyaluminum(6005T6)crankarmsfastenedtozinc-platedsteelpivotrodsanddoublysecuredwithinchannelrunningalongtopofblade.Largediameter11/32"(8.73mm)hardalloyaluminum(6065-T6C)linkagerodconnectsthecrankarmsbymeansofazinc-platedsteeltrunnion.

• Cup-pointtrunnionscrewallowsforapenetratinggripofthelinkagerod. (Cup-point trunnion set screw creates a compression hard spot where it secures to the linkage rod.)

• Trunnionsarezinc-platedtoprovideahard,smoothandlong-lastingrotatingsurface.

• Counterweightedbackdraftdampersaredesignedforoperationintemperaturesrangingbetween-40°F(-40°C) and212°F(100°C).

• Airleakagethrougha24"x24"(610mmx610mm)counterweightedbackdraftdamperdoesnotexceed20cfm/ft.²(101.2l/s/m²) against1"(.25kPa) w.g. differential static pressure at standard air.

• Counterweightedbackdraftdampersaremadetosizerequired. Minimumsectionsize:6”widex6”high(152mmx152mm) Maximumsectionsize:36”widex144”high(914mmx3658mm)(Mullion breaks will be used when damper height exceeds 48 inches.)

Counterweightedbackdraftdamperswithdimensionsgreaterthanmaximumsectionsizewillbemanufacturedinmultiplesections.Multiplesectionsarenotinterlinkedorconnected.Toinstall,eachsectionmustbeindividuallyfastenedtoastructuralframepreparedonsite.

• Availableinthreemountingtypes:"RearFlange","InDuct",or"FrontFlange".

S E R I E S 7 0 0 0 C WCOUNTERWE IGHTED BACK DRAFT DAMPER

Note:• Suitableforoperationinbreathableairenvironmentswithinstated

temperature range.• ¼" is deducted from the opening dimensions to allow for clearance on

mounting types Rear Flange, In Duct, Front Flange.• ¼" clearance deducted from Rear Flange and Front Flange mounting

types affects effective flange.

For additional information, refer to:• Series 7000 Specification Sheet• Series7000WTSpecificationSheet

2.5"63.50 mm

fully open

5"127 mm

1 7/8"47.6 mm

5/8"15.9 mm

5/8"15.9 mm

FrontFlange

In DuctRearFlange

Vertical Mount / Air Flow Horizontal

Horizontal Mount /Air Flow Up

Horizontal Mount /Air Flow Down

47

Page 53: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

PRESSURE DROP

Airvelocityinfeetandmetersperminutethroughfacearea.TestedperAMCAStandard500,Figure5.5,ductworkupstreamanddownstream.

BLADE L IMITATIONS

Series7000CWCounterweightedBackDraftDampersthatexceedthemaximumdesignpressureorvelocityduetobladelengthmaybeusedbyreducingthewidthofthebackdraftdampersection(s)andincreasingthenumberofsectionsperdamperto

maintainabladelengthcompatiblewiththestatedsystempressureorvelocity.

Example: 1 section Series 7000 CW Counterweighted Back Draft Damper of 36”w x 36”h @ 3000 fpm would need to be built in 2 sections of 18”w x 36”h.

36"

30"

24"

18"

12"2500 2750 3000 3250 3500

LEN

GTH

OF

BLA

DE

(inch

es)

SYSTEM VELOCITY (fpm)

MAX. BLADE LENGTH vs. MAX. DESIGN VELOCITY (fpm)

36"

30"

24"

18"

12"4.0 4.5 5.0 5.5 6.0

LEN

GTH

OF

BLA

DE

(inch

es)

PRESSURE (in. w.g.)

MAX. BLADE LENGTH vs. MAX. BACK PRESSURE (in. w.g.)

Pres

sure

Dro

p (in

ches

w.g

.)(in

take

mod

e)

VELOCITY VS. PRESSURE DROP10.0

1.0

0.1

0.01100 1,000 10,000

24" x 24"(610mm x 610mm)

Face Velocity (ft./min.) AMCA Figure 5.5

DAMPER WIDTH

Leakage at 1" w.g.cfm / sq. ft.

36" (914mm) 15.024" (610mm) 20.012" (305mm) 40.0

Series 7000 CW Test Data:Alltestswereconductedona24"x24"(610mmx610mm)rearflangemounttypecounterweightedbackdraftdamper.Thedatarepresenttheperformanceofthestatedsizeonlyandcannotbetransferreddirectlytoothersizes.Thisdataismeantonlyasanindicatorofthepressuresandvelocitiesneededforallthesizesavailable.

Static Pressure and Face Velocity to Open Damper:Counterbalanceweightsarefullyadjustableandcanbesettorelieveairpressuredifferentialslessthan.01in.w.g.

S E R I E S 7 0 0 0 C WCOUNTERWE IGHTED BACK DRAFT DAMPER

48

Page 54: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S E R I E S 3 0 0 0STORMPROOF LOUVERS

• Series3200framesare2"(51mm) deep. Series3400framesare4"(102mm)deep. Series3600framesare6"(152mm)deep.

• Bladesarefixedata45°angle.

• Mullionorcontinuousbladetype.

• Channelorexteriorflangeframe.• Incorporatesanoffsetdesignfeaturetoreduce

water penetration. (Offset feature also serves to stiffen the blade and

reduce the possibility of vibration.)

SERIES 3000 STORMPROOF BLADE (side view)

S E R I E S 4 0 0 0STANDARD LOUVERS

• Series4200framesare2"(51mm) deep. Series4400framesare4"(102mm)deep. Series4600framesare6"(152mm)deep.

• Bladesarefixedata45°angle.

• Mullionorcontinuousbladetype.

• Channelorexteriorflangeframe.• OperateswithslightlylowerpressuredropascomparedtoStormprooftypes.

(The standard louver's lower pressure drop can be used to advantage in exhaust applications.)

SERIES 4000 STANDARD BLADE (side view)

• 0.5x0.5"(12.7mmx12.7mm)x19gaugegalvanizedsteelmeshbirdscreen.Galvanizedscreenisfasteneddirectlytolouver.

• 0.5"x0.5"(12.7mmx12.7mm)x.063"(1.6mm) aluminum mesh bird screen. Aluminum screen is in a separate frame fastened to the louver.

• 18x16/in.²(7.1x6.3/cm²) aluminum mesh insect screen.

O P T I O N A LSCREENS

• Aluminumlouversprovideaprolongedandrust-freeoperationallife.

• Aluminum(6063T5)extrusionsallowforintricatedesignfeaturesnotpossiblewith roll or brake formed materials.

• Extrudedaluminumprofilesallowforadditionalthicknessofmaterialatradiiand stress points.

• Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,thefilmreforms.

(Louversproducedinmillfinish.Optionalfinishesavailable:baked/fluoropolymerenamel/clear&coloranodizing.)

A L U M I N U MSTRENGTH AND DURABILITY

•TAMCOofferslouverdesignsthatprovideforadurableanddependableproduct.

•TAMCO'scustomerservicepeopleensurecorrectproductselection. (Customer approval sheets oblige purchaser to verify TAMCO Series numbers.)•TAMCOprovidesatoll-freecustomerservicenumberandhastechnicalsupport

available.

•TAMCOproductsandpersonnelareyourguaranteeoftotalperformance.

T O T A LPERFORMANCE

• Equippedwithconcealedstructuralsupport.

• Rigidextrudedaluminumbraceconnectsthebladestothehidden structural supports.

• Invisiblejunctionsallowexpansionandcontraction,preventlineardeformationandunsightlywaveringofblades.

• Channelorexteriorflangeframes.

L O U V E R S T Y L ECONTINUOUS BLADE TYPE

• Sectionsconnectbothhorizontallyandvertically.

• Suppliedwithabuilt-incaulkingslotallthewayaroundtheframe. (Caulking slot doubles as sliding, interlocking protrusion when mated with

additional sections and makes for smooth appearance.)• Installationpossiblefrominteriororexteriorofbuilding.

F R A M E T Y P ECHANNEL

•Slidingmullionsinterlocksectionsforeasyinstallationinthefield.

•Channelorexteriorflangeframes.

L O U V E R S T Y L EMULLION TYPE

• Sectionsconnectbothhorizontallyandvertically.

• Allowsforexteriorsurfacemountinginstallationwhichconcealspossible gaps between louver and opening.

F R A M E T Y P EEXTERIOR FLANGE

C O N T I N U O U S B L A D E & M U L L I O N T Y P EFIXED-BLADE LOUVERS

S E R I E S 3000 & 4000

49

Page 55: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

MULLION OR CONTINUOUS BLADE

TYPE SECTION (channel frame)

INTERLOCKED MULLION

(between sections)

CONCEALED MULLION (continuous blade type)

F R A M E T Y P ECHANNEL

F R A M E T Y P EEXTERIOR FLANGE

MULLION OR CONTINUOUS BLADE TYPE SECTION

(exterior flange frame)

INTERLOCKED MULLION (between sections)

CONCEALED MULLION (continuous blade type)

Determinevelocity(fpm)bydividingtheairvolume(cfm)bythefreearea(ft.²)figureobtainedinthefreeareachartswhichfollow.Enterchartatthedeterminedvelocity(fpm)indicatedatthebottomofchart.Continueupuntilcurveofdesiredseriesisintersected.Readacrosstoobtainpressuredropoflouver.

S E R I E S 4 0 0 0PRESSURE DROP

S E R I E S 3 0 0 0PRESSURE DROP

WATER PENETRATION

3200 679ft./min.(3.45m/s)

3400 695ft./min.(3.53m/s)

3600 732ft./min.(3.72m/s)

4200 775ft./min.(3.94m/s)

4400 685ft./min.(3.48m/s)

4600 775ft./min.(3.94m/s)

[email protected]./ft.²(3.05g/m²)

L O U V E R S T Y L EMULLION TYPE

MULLION TYPE SECTIONS INTERLOCK (front view)

L O U V E R S T Y L ECONTINUOUS BLADE TYPE

CONTINUOUS BLADE TYPE FOR UNINTERRUPTED BLADE LINE (front view)

50

Page 56: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

Note: Maximum size of section is based on self-supporting, non-blanked-off sections at maximum width, supported at top & bottom only, up to 30 lb. wind load.

BIRD SCREEN(TYPICAL)

CAULKING SLOT(TYPICAL)

STRUCTURAL SUPPORT

(CONCEALED MULLION)

CD

B

A

BLADE BRACE

SERIES 4000MULLION TYPE

CHANNEL FRAME

SERIES 4000MULLION TYPE

CHANNEL FRAME

SERIES 3000CONTINUOUS

BLADECHANNEL

FRAME

SERIES 3000CONTINUOUS

BLADECHANNEL

FRAME

SERIES 3000MULLION TYPE

EXTERIOR FLANGE

SERIES 3000MULLION TYPE

EXTERIOR FLANGE

SERIES 4000CONTINUOUS

BLADECHANNEL

FRAME

SERIES 4000CONTINUOUS

BLADECHANNEL

FRAME

F I X E D B L A D ELOUVERS

S E R I E S 3 0 0 0INTAKESERIES 3200SERIES 3400SERIES 3600

S E R I E S 4 0 0 0EXHAUSTSERIES 4200SERIES 4400SERIES 4600

• Extrudedaluminum(6063T5)framesforSeries3000&4000louvers(exceptionisSeries3600&4600)arenotlessthan.072"(1.83mm)thickness.Extruded(6063T5)aluminumframesforSeries3600&4600louversarenotlessthan.098"(2.50mm)thickness.Frameis:

2" (51mm)deep/Series3200/4200. 4"(102mm)deep/Series3400/4400. 6" (152mm)deep/Series3600/4600.

• LouverbladesforSeries3200&4200areextrudedaluminum(6063T5) profiles and not less than .063"(1.60mm)inthickness.Series3400&4400louverbladesarenotlessthan.071"(1.80mm) in thickness.Series3600&4600louverbladesarenotlessthan.081"(2.06mm)inthickness.Louverbladesarefixedata45°angle.

• Mountingframesarechannel(U-frame)orexteriorflange(L-frame).

• BladetypeisIntake(Series3000)orExhaust(Series4000).

• Mullionorcontinuousbladestyleconstruction.

• Birdscreensareconstructedof0.5"x0.5"x0.032”(12.7mmx12.7mmx.81mm)galvanizedsteelwiremesh,completewithframe.

• Optionalstainlesssteelbirdscreensareconstructedof0.5"x0.5"x0.063”(12.7mmx12.7mmx1.60mm)wiremesh.Whenspecified,stainlesssteelbirdscreensreplacegalvanizedsteelbirdscreens.

• Optionalaluminumbirdscreensareconstructedof0.59"x1.20"x0.045”(15mmx30.5mmx1.14mm)wiremesh.Whenspecified,aluminumbirdscreensreplacegalvanizedsteelbirdscreens.

• Optionalinsectscreensareavailableandconstructedof18x16/in.²(7.1x6.3/cm²)aluminum mesh. Thegaugeis0.012"(0.30mm).Whenspecified,insectscreensreplacebirdscreens.

• Birdscreensandinsectscreensarefastenedtothelouver.

• Louversaremadetosizerequired.

Note:• Toallowforclearance,¼"isdeductedfromalldimensions.When

ordering, always specify actual duct or opening size.

For additional information, refer to:• Series 3000 & 4000 Free Area Charts

min. size (3000/4000)

2" deep frame 2" 0.625" 1.5" 0.375" 8" high4" deep frame 4" 1" 2" 0.375" 12" high 6" deep frame 6" 1.75" 2." 0.375" 16" high

A B C D

51

Page 57: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

PERFORMANCE DATA

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 3 2 0 0FREE AREA (sq. ft.)

1224364860728496

120.32

0.78

1.29

1.72

2.19

2.69

3.12

3.61

180.48

1.16

1.93

2.58

3.29

4.03

4.67

5.42

240.64

1.55

2.58

3.44

4.39

5.37

6.23

7.22

300.81

1.94

3.22

4.30

5.48

6.71

7.79

9.03

360.97

2.33

3.87

5.16

6.58

8.06

9.35

10.80

421.13

2.71

4.51

6.02

7.68

9.40

10.90

12.60

481.29

3.10

5.16

6.88

8.77

10.70

12.50

14.40

541.45

3.49

5.80

7.74

9.87

12.10

14.00

16.20

601.61

3.88

6.45

8.59

11.00

13.40

15.60

18.10

WIDTH (in.)

HEI

GH

T (in.)

S E R I E S 3 4 0 0FREE AREA (sq. ft.)

1224364860728496

120.29

0.91

1.37

1.97

2.51

3.03

3.65

4.11

180.43

1.37

2.06

2.96

3.77

4.54

5.48

6.17

240.58

1.82

2.74

3.94

5.02

6.06

7.30

8.22

300.72

2.28

3.43

4.93

6.28

7.57

9.13

10.28

360.87

2.74

4.11

5.91

7.54

9.09

10.96

12.33

421.01

3.19

4.80

6.90

8.79

10.60

12.78

14.39

481.16

3.65

5.48

7.88

10.05

12.12

14.61

16.44

541.30

4.11

6.17

8.87

11.30

13.63

16.44

18.50

601.45

4.56

6.85

9.85

12.56

15.15

18.26

20.55

WIDTH (in.)

HEI

GH

T (in.)

S E R I E S 3 6 0 0FREE AREA (sq. ft.)

1224364860728496

120.31

0.94

1.59

2.25

2.91

3.57

4.22

4.88

180.46

1.41

2.39

3.38

4.36

5.35

6.34

7.32

240.62

1.87

3.19

4.50

5.82

7.13

8.45

9.76

300.77

2.34

3.99

5.63

7.27

8.92

10.60

12.20

360.92

2.81

4.78

6.76

8.73

10.70

12.70

14.60

421.08

3.28

5.58

7.88

10.20

12.50

14.80

17.10

481.23

3.75

6.38

9.01

11.60

14.30

16.90

19.50

541.39

4.22

7.18

10.10

13.10

16.00

19.00

12.00

601.54

4.69

7.97

11.30

14.50

17.80

21.10

24.40

WIDTH (in.)

HEI

GH

T (in.)

S E R I E S 4 2 0 0FREE AREA (sq. ft.)

1224364860728496

120.40

0.87

1.35

1.86

2.37

2.87

3.35

3.82

180.60

1.31

2.02

2.78

3.56

4.31

5.02

5.73

240.80

1.75

2.70

3.71

4.74

5.75

6.70

7.65

301.00

2.18

3.37

4.64

5.93

7.19

8.37

9.56

361.20

2.62

4.04

5.57

7.12

8.62

10.05

11.47

421.40

3.06

4.72

6.50

8.30

10.06

11.72

13.38

481.60

3.50

5.39

7.42

9.49

11.50

13.40

15.29

541.80

3.93

6.07

8.35

10.67

12.94

15.07

17.20

602.00

4.37

6.74

9.28

11.86

14.37

16.34

19.11

WIDTH (in.)

HEI

GH

T (in.)

S E R I E S 4 4 0 0FREE AREA (sq. ft.)

1224364860728496

120.38

0.96

1.53

2.11

2.68

3.26

3.83

4.40

180.57

1.44

2.30

3.16

4.02

4.88

5.75

6.61

240.77

1.92

3.06

4.21

5.36

6.51

7.66

8.81

300.96

2.39

3.83

5.27

6.70

8.14

9.58

11.01

361.15

2.87

4.60

6.32

8.04

9.77

11.50

13.20

421.34

3.35

5.36

7.37

9.38

11.40

13.40

15.40

481.53

3.83

6.13

8.43

10.70

13.00

15.30

17.60

541.72

4.31

6.89

9.48

12.10

14.70

17.20

19.80

601.92

4.79

7.66

10.50

13.40

16.30

19.15

22.00

WIDTH (in.)

HEI

GH

T (in.)

S E R I E S 4 6 0 0FREE AREA (sq. ft.)

1224364860728496

120.30

0.91

1.51

2.11

2.72

3.32

3.92

4.53

180.45

1.36

2.26

3.17

4.08

4.98

5.89

6.79

240.60

1.81

3.02

4.23

5.43

6.64

7.85

9.06

300.75

2.26

3.77

5.28

6.79

8.30

9.81

11.30

360.91

2.72

4.53

6.34

8.15

9.96

11.77

13.60

421.06

3.17

5.28

7.40

9.51

11.60

13.70

15.80

481.21

3.62

6.04

8.45

10.90

13.30

15.70

18.10

541.36

4.08

6.79

9.51

12.20

14.90

17.70

20.40

601.51

4.53

7.55

10.60

13.60

16.60

19.60

22.60

WIDTH (in.)

HEI

GH

T (in.)

FREE AREA CHARTS

52

Page 58: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

FA C E A N D S I D E R E M O VA B L EINSECT SCREENS

S E R I E S 6 0 0 0

A L U M I N U M

STRENGTH AND DURABILITY• Aluminuminsectscreensandframesprovideaprolongedandrust-freeoperationallifeovergalvanizedsteeltypes.

• Aluminumoxidizestoformaprotectivefilm.Ifthesurfaceisscratched,the film reforms.

(Standard insect screen is produced with a mill finish.)

S I L I C O N E

FRAME SEALS

• Siliconeframesealsoutperformallotherexistingsealsduetoflexibilityanddurability.

(Silicone seals have an estimated service life of 30 years.)

•Siliconesealsarevirtuallyunaffectedbycoldoperatingtemperatures.•Silicone’ssuperiordynamicfatigueresistanceensuresphenomenalresistancetoweathering,compressionset,andheat.

• TamcoInsectScreensaredesignedtoberemovedfromframeeasily,tofacilitate cleaning.

• Faceremovablescreensareeasilyliftedoutofthefrontoftheframe,usingnylonfingerpulls.

• Sideremovableinsectscreensaredesignedforinstallationswherefrontremoval is not possible. The screen slides out from the side of the frame using the pull handle.

F A C E O R S I D E

R E M O VA B L E• TamcoInsectScreensaretheidealsolutionforpreventingforeignparticlesfromenteringfiltrationsystems.

• Insect screens are perfect for fresh air intake applications in areas with highdensityinsectpopulationsandinareaspronetosmall,air-bornedebris accumulation.

I D E A L

S O L U T I O N

53

Page 59: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

www.tamco.ca

SPECIFICATIONS

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

• Extrudedaluminum(6063T5)frameisnotlessthan.06”(1.52mm)inthickness.Frameis2.5”(63.5mm) deep.

• Framesealsareextrudedsilicone.Sealsaresecuredinanintegralslotwithinthealuminumextrusions.

• Screenretentionconsistsofroll-formedaluminumwithsiliconeretainergaskets.

• Insectscreensare18x16mesh,.011gaugealuminum.

• Maximumsectionsizeis36"x60"(914mmx1524mm).

• Screensareavailableinthreemountingtypes:“InstalledinDuct”or“FlangedtoWall”arefacemounted."SideRemovable"is accessible from outside of the duct.

• Faceremovablescreensare"liftandremovetype"andcomewithnylonfingerpulls,mountedinscreenretentionframe.

• Screensmustbeinstalledasstandaloneunits.

• Installationofscreensmustbeinaccordancewithmanufacturer'sinstallationguidelines.

S E R I E S 6 0 0 0INSECT SCREEN

"Installed in Duct" Mount Type "Flanged to Wall" Mount Type2.5"63.5mm

.625"15.9mm

1.875"48mm

2.5"63.5mm

FACE REMOVABLE

SIDE REMOVABLE

54

Page 60: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

P U R P O S E - B U I L T

DESIGN

•Specificallydesignedbladeextrusionuniquetothisoption.• Alladvantagesofaluminumconstructionandmaintenance-freeoperationretained.

•Dependabilityanddurabilityof“DualBearingSystem”maintained. (See TAMCO Series 1000, 1000 SW, 1400 and 1400 SW product

information.)

S E L E C T A B L E

PERFORMANCE

•Choiceofmaterialtosuitoperatingenvironment.•Choiceofbadedepth(6”or4”).•Choiceofopposedorparallelbladeaction. (Blade action type must be the same for the Face

and for the Bypass sections of any unit.)

Note:• Suitable for operation in breathable air environments within

stated temperature range.

For additional information, refer to:• Face&BypassStandard Configurations• Series 1000,1000SW,1400and1400SW ProductInformationPages• Series 1000,1000SW,1400and1400SW Specification Sheets• Series 1500,1500SW,1000&1000SW Free Area Charts• Series 1400&1400SW Free Area Charts• TAMCO Aluminum Damper Torque Requirements• TAMCO Aluminum Damper Installation Guidelines

U N I N T E R R U P T E D

LINKAGE

•Nomechanismtoloosen,fail,oromit.•Transmissionoftorque,orstroke,isdirectandwithoutlosses.•Sectionconnectionswillnotdevelopunduewearorplay.

Face & Bypass damper linkage

FACE & BYPASS DAMPER

O P T I O N S E R I E S 1 0 00 , 1 0 00 SW, 1 4 00 , 1 4 00 SWFACE & BYPASS DAMPERS

55

Page 61: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

A

Available with both parallel and opposed blade action.CALL TAMCO CUSTOMER SERVICE FOR FACE & BYPASS DAMPERS

EXCEEDING MAXIMUM DIMENSIONS.

Note:• Suitable for operation in breathable air environments within stated

temperature range.• All data based on remaining within allowable maximum blade pressureasshownintheBladeDesignPressureLimitationschart.

MUST HAVE ADEQUATE SUPPORT FOR VERTICAL INSTALLATION OF FACE & BYPASS DAMPERSFor additional information, refer to:• Face&BypassOptionInformationPage• Series 1000&1000SWInformationPages• Series 1000&1000SWSpecification Sheets• Series 1500,1500SW,1000&1000SW Free Area Charts• Series 1400&1400SW Free Area Charts• TAMCO Aluminum Damper Torque Requirements• TAMCO Aluminum Damper Installation Guidelines

SERIES 1000/1000 SW/1400/1400 SW

FLANGED TO DUCT TYPEMINIMUM & MAXIMUM SIZES:

OVERALL DUCT SIZES X

MINIMUM: 6”w x 10.5”hMAXIMUM: 60”w x 60”h or 48”w x 75”h

FACE & BYPASS SIZES &

MINIMUM: 4¼”h

MAXIMUM AREA:25 ft.²

C1

B

C2

INSTALLED IN DUCT TYPEMINIMUM & MAXIMUM SIZES:

OVERALL DUCT SIZES X

MINIMUM: 6”w x 12.5”hMAXIMUM: 60”w x 60”h or 48”w x 75”h

FACE & BYPASS SIZES &

MINIMUM: 4¼”h

MAXIMUM AREA:25 ft.²

A

C1

B

C2

2” added to duct width and height dimensions.

Up to 25 ft.²: 1 motor location operated with a minimum of 1 motor.

UNLESS OTHERWISE SPECIFIED, ONE-SECTION-WIDE DAMPERS ARE SUPPLIED RIGHT HAND.

ONE-SECTION-WIDE DAMPERS ARE AVAILABLE WITH LEFT HAND DRIVE.

½” deducted for clearance from duct width and height dimensions.

Up to 25 ft.²: 1 motor location operated with a minimum of 1 motor.

ONE SINGLE SECTION WIDE - AUTO LINKED

1”

A

C2

C1

2”

1”

B

1”

A

C2

C1

2”

2”

1”

B

1” 1”

STANDARD CONFIGURATIONS

56

Page 62: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Dampers are sized 4" (102mm) larger than specified duct diameter.(Dampers are fabricated square.)

3"(76mm)

1¼"(32mm)

¼" (6.35mm)less than specified

4"(102mm)

12½"(318mm)

Diameter is ¼" (6.35mm) less than specified duct size. To ensure free movement of damper blades, mating duct slides over round connection of damper.

SPECIFICATIONSAdditional to S ER I ES : 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW Specifications

•Mountingtypeis"Square-to-Round" (replaces "Flanged to Duct" & "Installed in Duct").•Transitionpiecestobeofminimum18ga.galvanizedsteel for Series 9000 BF, 9000

ECT, 9000, 9000 SC, 1500 and 1000 dampers.•Transitionpiecestobe304 stainless steel for Series 9000 SW, 1500 SW and 1000 SW

Salt Water Resistance dampers.•Sealanttobeusedbetweentransitionpiecesanddamperflanges.

Polystyrene insulation on all four sides.

INSULATED DAMPERS NON-INSULATED DAMPERS

O P T I O N S Q U A R E - T O - R O U N DT R A N S I T I O N

57

2"(51mm)

4"- 6"(102mm - 152mm)

58" (1474mm) Maximum duct diameter 4" (102mm) Minimum duct diameter

62"(1575mm)

Square maximum

1"(25mm)

up to1 5/16"(33mm)

Linkage extends up to 15/16” beyond the outer edge of the transition.

Page 63: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

CONFIGURATION 1SINGLE-SECTION DAMPER

MINIMUM SIZE: 6½”w x 6¾”h “Installedinduct”4½”wx4¼”h “Flangedtoduct”

MAXIMUM SIZE: 60”w x 60”h or48”w x 75”h(Limiting width to 48” allows height to increase to 75”.)

MAXIMUM AREA:25 ft.²(See A and B for details.)

A

B

Up to 25 ft.²: 1 motor location operated with a minimum of 1 motor.

Up to 25 ft.²: 1 motor location. Damper to be ordered with a face blade bracket. Operated with a minimum of 1 motor, connected to face blade bracket.

UNLESS OTHERWISE SPECIFIED, SINGLE-SECTION DAMPERS ARE SUPPLIED RIGHT HAND.

ONE-SECTION-WIDE DAMPERS

CONFIGURATION 2-1VERTICAL TWO-SECTION DAMPER

MINIMUM SIZE: 6½”wxover75”h“Installedinduct”4½”wxover75”h“Flangedtoduct”

MAXIMUM SIZE: 60”w x 120”h or 48”w x 150”h(Limiting width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:50 ft.²(See A and B for details.)

B

A Up to 50 ft.²: 2 motor locations. Operated with a minimum of 1 motor on both top and bottom sections. Total minimum of 2 motors.

Over 25 ft.² through 50 ft.²: 2 motor locations. Damper to be ordered with a vertical jack shaft. Operated wi th a minimum of 1 motor connected to either top or bottom section. Total minimum of one motor.

UNLESS OTHERWISE SPECIFIED, VERTICAL TWO-SECTION DAMPERS ARE SUPPLIED RIGHT HAND.

LEFT HAND RIGHT HAND

A A

RIGHT HANDLEFT HAND

A A

LEFT HAND RIGHT HAND

B B

CONFIGURATION 3-1VERTICAL THREE-SECTION DAMPER

MINIMUM SIZE: 6½”wxover150”h“Installedinduct”4½”wxover150”h“Flangedtoduct”

MAXIMUM SIZE: 60”w x 180”h or 48”w x 225”h(Limiting width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:75 ft.²

Up to 75 ft.²: 3 motor locations. Operated with minimum of 1 motor connected to each section: top, middle and bottom. Total minimum of 3 motors.

Note: All three sections for this configuration cannot be connected with vertical jack shafts. A maximum of two sections can be connected vertically.

UNLESS OTHERWISE SPECIFIED, VERTICAL THREE-SECTION DAMPERS ARE SUPPLIED RIGHT HAND.

B B

LEFT HAND RIGHT HAND

CWROTATION TO OPEN

LEFT HAND

CCWROTATION TO OPEN

RIGHT HAND

Contact TAMCO CUSTOMER SERVICE for possible conf igurat ions not shown.

NOTE: For Series 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/ 1500 SW/1000/1000 SW/1400/1400 SW

All data based on remaining within allowable maximum blade pressure as shown in the Blade Design Pressure Limitations chart.

FOR ADDITIONAL INFORMATION, REFER TO:•JumpersforMultiple-SectionAluminumDampers•JackShaftsforMultiple-SectionAluminumDampers•VerticalJackShaftsforMultiple-SectionAluminumDampers•TAMCOAluminumDamperInstallationGuidelines

58

Page 64: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

TWO-SECTIONS-WIDE DAMPERS

CONFIGURATION 2HORIZONTAL TWO-SECTION DAMPER

MINIMUM SIZE: Over60”wx6¾”h “Installedinduct”Over60”wx4¼”h “Flangedtoduct”

MAXIMUM SIZE: 120”w x 60”h or96”w x 75”h(Limiting section width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA: 50 ft.²(See A, B, C and D for details.)

CONFIGURATION 2-2FOUR-SECTION DAMPER

MINIMUM SIZE: Over 60”w x over 60”h

MAXIMUM SIZE: 120”w x 120”h or 96”w x 150”h(Limiting section width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:100 ft.²(See A, B, and C for details.)

Up to 30 ft.²: 2 motor locations. Damper supplied with damper jumper. Operated with a minimum of 1 motor, from either right or left side. Total minimum of 1 motor.

Over 30 ft.² through 50 ft.²: 2 motor locations. Operated with a minimum of 1 motor on both left and right sides. Total minimum of 2 motors.

Up to 50 ft.²: 2 motor locations. Damper to be ordered with two face blade brackets. Operated with a minimum of 1 motor connected to both left and right section face blade brackets. Total minimum of 2 motors.

Over 30 ft.² through 50 ft.²: 1 motor location. Damper to be ordered with a damper jack shaft. Operated with a minimum of one motor connected to jack shaft. Mounting holes are pre-drilled to allow jack shaft to mount either on left or right. Total minimum of 1 motor.

C

B

D

A

Up to 60 ft.²: 2 or 4 motor locations. Damper supplied with damper jumpers. Operated from right or left side with minimum of 1 motor on both top and bottom sections, or with a minimum of 1 motor on all four sections. Total minimum of 2 or 4 motors.

Over 50 ft.² through 100 ft.²: 4 motor locations. Damper to be ordered with vertical jack shafts. Operated from right and lef t side with a minimum of 1 motor connected to either top or bottom sections. Total minimum of 2 motors.

Over 60 ft.² through 100 ft.²: 2 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor connected to both top and bottom jack shafts. Mounting holes are pre-drilled to allow jack shaft to mount either on left or right. Total minimum of 2 motors.

B

C

A

A B

C

D

D

A

C

B

C

59

Page 65: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

TWO-SECTIONS-WIDE DAMPERS

CONFIGURATION 3-2SIX-SECTION DAMPER

MINIMUM SIZE: Over 60”w x over 120”h

MAXIMUM SIZE: 120”w x 180”h or 96”w x 225”h(Limiting section width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:150 ft.²(See A and B for details.)

A

B

Up to 90 ft.²: 3 or 6 motor locations. Damper supplied with damper jumpers. Operated from right or left side with minimum of 1 motor connected to each of the top, middle and bottom sections, or with a minimum of 1 motor on all six sections. Total minimum of 3, or 6 motors.

Over 90 ft.² through 150 ft.²: 3 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of one motor connected to each of the top, middle and bottom jack shafts. Mounting holes are pre-drilled to allow jack shafts to mount either on left or right. Total minimum of 3 motors.

Note: Three sections cannot be connected with vertical jack shafts. A maximum of two sections can be connected vertically.

Four-section-high dampers may have the two top sections connected with one vertical jack shaft, and the two bottom sec t ions connec ted wi th another vertical jack shaft.

A

B

B

60

Page 66: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

THREE-SECTIONS-WIDE DAMPERS

CONFIGURATION 3HORIZONTAL THREE-SECTION DAMPER

MINIMUM SIZE:Over120”wx6¾”h “Installedinduct”Over120”wx4¼”h “Flangedtoduct”

MAXIMUM SIZE:180”w x 60”h or144”w x 75”h(Limiting section width to 48” allows height to increase to 75”.)

MAXIMUM AREA:75 ft.²(See A, B, and C for details.)

Up to 75 ft.²: 3 motor locations. Damper to be ordered with drive blade brackets. Operated with a minimum of 1 motor connected to each; left, centre and right damper drive blades. Total minimum of 3 motors.

Up to 75 ft.²: 2 motor locations. Damper to be ordered with a damper jack shaft. Operated with a minimum of 1 motor, connected to a single section and 1 motor connected to the jack shaft. Mounting holes are pre-drilled to allow jack shaft to extend beyond either the left end or the right end section. Total minimum of 2 motors.

Up to 75 ft.²: 1 motor location. Damper to be ordered with a damper jack shaft. Operated with a minimum of 1 motor connected to the jack shaft. Mounting holes are pre-drilled to allow jack shaft to extend beyond either the left end or the right end section. Total minimum of 1 motor.

C

Up to 150 ft.²: 4 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor, connected to each: top and bottom single sections and 1 motor connected to each: top and bottom jack shafts. Mounting holes are pre-drilled to allow jack shafts to extend beyond either the left end or the right end sections. Total minimum of 4 motors.

Up to 150 ft.²: 2 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor, connected to each: top and bottom jack shafts. Mounting holes are pre-drilled to allow jack shaft to extend beyond either the left end or the right end sections. Total minimum of 2 motors.

Note: Vertical jack shafts are available for this configuration.

A

B

C

CONFIGURATION 2-3SIX-SECTION DAMPER

MINIMUM SIZE:Over 120”w x over 60”h

MAXIMUM SIZE:180”w x 120”h or144”w x 150”h(Limiting section width to 48” allows height to increase to 75”.)

MAXIMUM AREA:150 ft.²(See A and B for details.)

A

B

A

B

B

A

A

B

B

C

A

61

Page 67: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

THREE-SECTIONS-WIDE DAMPERS

Up to 225 ft.²: 6 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor, connected to each: top middle and bottom single sections and 1 motor connected to each: top, middle and bottom jack shafts. Mounting holes are pre-drilled to allow jack shafts to extend beyond either the left end or the right end sections. Total minimum of 6 motors.

Up to 225 ft.²: 3 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor, connected to each: top, middle and bottom jack shafts. Mounting holes are pre-drilled to allow jack shafts to extend beyond either the left end or the right end sections. Total minimum of 3 motors.

Note: Three sections cannot be connected with vertical jack shafts. A maximum of two sections can be connected vertically.

Four-section-high dampers may have the two top sections connected with one vertical jack shaft, and the two bottom sections connected with another vertical jack shaft.

CONFIGURATION 3-3NINE-SECTION DAMPER

MINIMUM SIZE:Over 120”w x over 120”h

MAXIMUM SIZE:180”w x 180”h or144”w x 225”h(Limiting section width to 48” allows height to increase to 75”.)

MAXIMUM AREA:225 ft.²(See A and B for details.)

B

A

A

B

B

A

62

Page 68: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

FOUR-SECTIONS-WIDE DAMPERS

Up to 100 ft.²: 4 motor locations. Damper to be ordered with damper blade brackets. Operated with a minimum of 1 motor connected to each damper section drive blade. Total minimum of 4 motors.

Up to 60 ft.²: 2 motor locations. Damper supplied with damper jumpers. Operated with a minimum of one motor connected to each: the left end and right end sections. Total minimum of 2 motors.

Over 60 ft.² through 100 ft.²: 2 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of one motor connected to each: the left and right jack shafts. Total minimum of 2 motors.

Over 60 ft.² through 100 ft.²: 1 motor location. Damper to be ordered with a damper jack shaft. Operated with minimum of 1 motor connected to the jack shaft. Mounting holes are pre- drilled to allow jack shaft to extend beyond either the left end or the right end section. Total minimum of 1 motor.

CONFIGURATION 4HORIZONTAL FOUR-SECTION DAMPER

MINIMUM SIZE: Over120”wx6¾”h “Installedinduct”Over120”wx4¼”h “Flangedtoduct”

MAXIMUM SIZE:240”w x 60”h or192”w x 75”h(Limiting section width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:100 ft.²(See A, B, C and D for details.)

A

B

C

D

B

C

D

D

A

63

Page 69: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

A L U M I N U M D A M P E RSTANDARD CONFIGURATIONS

FOUR-SECTIONS-WIDE DAMPERS

Up to 120 ft.²: 4 motor locations. Damper supplied with damper jumpers. Operated with a minimum of 1 motor connected to each: the top and bottom, right and left sections. Total minimum of 4 motors.

Over 120 ft.² through 200 ft.²: 4 motor locations. Damper to be ordered with damper jack shafts. Operated with a minimum of 1 motor connected to each jack shaft, top and bottom, at right and left. Total minimum of 4 motors.

Over 120 ft.² through 200 ft.²: 2 motor locations. Operated with a minimum of 1 motor connected to each: the top and bottom jack shafts. Mounting holes are pre-drilled to allow jack shafts to extend beyond either the left end or the right end sections.

CONFIGURATION 2-4EIGHT-SECTION DAMPER

MINIMUM SIZE: Over 120”w x over 60”h

MAXIMUM SIZE:240”w x 120”h or 192”w x 150” h(Limiting section width to 48" allows height to increase to 75” per section.)

MAXIMUM AREA:200 ft.² (See A, B and C for details.)

A

B

C

A

B

C

C

64

Page 70: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

M U L T I P L E – S E C T I O N

HORIZONTAL JACK SHAFTSREFER TO STANDARD CONFIGURATIONS SHEET FOR APPLICABILITY

LOCKING COLLAR LOCKING COLLAR

Jack shaft CRANK ARM

SWIVEL (5/16" Ø ROD)

SIDE BRACKET

1" Ø SHAFT

1" Ø RE-GREASABLE BRONZE BEARING

BLADE CRANK ARM

BRIDGE BRACKET

BLADE CLIP

5/16" Ø STEEL CONNECTING ROD

NOTE:•Minimumheightofductopeningforinstallationofthedamperjackshaftis11½" for "Flanged to Duct" and 15" for

"Installed in Duct".•Forshorterductopeningheightsdownto4¼"("FlangedtoDuct")and6¾"("InstalledinDuct"),specialnon-jackshaftblade-to-bladejoiningispossible.DrivenbladesareconnectedbytheuseofU-boltsandhexrodswhichspanthesections.

• For Series 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW.

STANDARD Jack shaft

•Side&bridgebracketsandbladeclipsaredie-formed10ga.CRSsteel.•Shaftis1"diametersolidsteelrod.•Jackshaftandbladecrankarmscomposedofstampedarmsweldedtomachinedcollars.•Allsteelcomponentsarezinc-plated.•Medium-dutybearingsarepre-greasedandequippedwithgreasenipples.•Jackshaftsarepre-assembledandreadytomountinpre-drilledholeswithprovidedfasteners.

STANDARD BEARINGS

•Optionaljackshaftbridgecouplingallowsforthedrivingofafour(4)sectiondamperfromeithertheleftorrightside.

•Couplingmeasures1½" O.D. x 1" I.D. x 4" LG c/w 8¼"-20 cup-point set screws

•Jackshaftsaremounteddirectlyover the drive blade in order to reduce the length of the 5/16" diameter steel connecting rod. The shortness of the rod prevents flexing and adds to positive control.

•Jackshaftscanbemountedsoastodriveatwo(2) section damper from either the left or right side.

65

Page 71: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

C O N F I G U R A T I O N S

USING VERTICAL JACK SHAFTSContact TAMCO CUSTOMER SERVICE for possible configurations not shown below.

NOTE: All data based on remaining within allowable maximum blade pressure as shown in the Blade Design Pressure Limitations chart.

CONFIGURATION 2-1VERTICAL TWO-SECTION DAMPER

MINIMUM SIZE: 6½”wxover75”h“Installedinduct”4½”wxover75”h“Flangedtoduct”

MAXIMUM SIZE: 60”w x 120”h or48”w x 150”h(Limiting width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:50 ft.²

Over 25 ft.² through 50 ft.²: 2 motor locations. Damper to be ordered with a vertical jack shaft. Operated with a minimum of 1 motor connected to the vertical jack shaft at either top or bottom. Total minimum of 1 motor.

UNLESS OTHERWISE SPECIFIED, VERTICAL TWO-SECTION DAMPERS ARE SUPPLIED RIGHT HAND.

LEFT HAND RIGHT HAND

CONFIGURATION 2-2FOUR-SECTION DAMPER

MINIMUM SIZE: Over 60”w x over 60”h

MAXIMUM SIZE: 120”w x 120”h or 96”w x 150”h(Limiting section width to 48” allows height to increase to 75” per section.)

MAXIMUM AREA:100 ft.²

Over 50 ft.² through 100 ft.²: 2 motor locations. Damper to be ordered with vertical jack shafts. Operated from right and lef t side with a minimum of 1 motor connected to each vertical jack shaft, at either top o r bo t t om. Total minimum of 2 motors.

Note: Three sections cannot be connected with vertical jack shafts. A maximum of two sections can be connected vertically.

Drive blade connected

5/16" cap shaft

1" hollow vertical shaft

Swivel

NOTE: For Series 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW.

66

Page 72: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

M U L T I P L E – S E C T I O N

DAMPER JUMPERSREFER TO STANDARD CONFIGURATIONS SHEET FOR APPLICABILITY

•JumperBrackethalvesaredie-formed10ga.CRSsteelwithzinc-platedcomponentsforSeries9000, 9000 SC, 9000 BF, 9000 ECT, 1500 and 1000 dampers.

• Jumper Bracket halves are 304 stainless steel with stainless steel components for Series 9000 SW, 1500 SW and 1000 SW Salt Water Resistance dampers.

•Jumperispre-assembledandreadytomounttoU-boltslocatedonthedamperdriveblade.•Slottedmatingsurfacesallowforsimpleadjustmentasrequired.

LEFT SIDE BRACKET

RIGHT SIDE BRACKET

HEX WASHER HEAD CAP SCREWS FLANGED NUT

Bracket can be offset to ensure proper torque is being applied to

each damper section.

NOTE: If actuators are to be connected to each section, the jumper bracket should not be installed, as the failure of one motor may prevent the remaining motor from operating normally, or at all. (Configurations 2 & 2-2 (horizontal sections only))

NOTE:•Minimumheightofductopeningforinstallationofthedamperjackshaftis13¼" for "Flanged to Duct" and 14" for

"Installed in Duct".•For shorter duct opening heights down to 4¼" ("Flanged to Duct") and 6¾" ("Installed in Duct"), special blade-to-bladejoiningispossible.DrivenbladesareconnectedbytheuseofU-boltsandhexrods,whichspanthesections.

• For Series 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW.

67

Page 73: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

T A M C O A L U M I N U M D A M P E R

TORQUE REQUIREMENTS

NOTE:Refer to Blade Design Pressure Limitations to ensure that the damper is within the stated design limits in respect to maximum static pressure. (See Series 9000 BF/9000 ECT/9000/9000 SC/9000 SW/1500/1500 SW/1000/1000 SW/1400/1400 SW) literature.)

1218243036424854606672

122345567789

10

18456789

1011121314

245679

10111214151617

30689

1112141517182021

3679

111315161820222325

429

11131517192123252729

481012151719222426283133

541114161922242729323437

601215182124273032353841

DAMPER WIDTH (in.)

DA

MPER

HEI

GH

T (in.)

1218243036424854606672

12358

1012141618212325

1859

131620232730343741

247

13172227323742475257

301016222935414854606673

361220273543505866738188

4214233241505968778695

120

481727374858687990

100110136

5419314254667789

101113124136

60213447607387

100113126139152

DAMPER WIDTH (in.)

DA

MPER

HEI

GH

T (in.)

Values in Sealing Torque chart (left) reflect the maximum torque requirements up to 2 in. w.g. and/or 1000 fpm face velocity. Refer to Velocity or Pressure Torque charts (below) if system design surpasses criteria of Sealing Torque chart. Base torque requirements on the greatest value obtained.

SEALING TORQUE (in.-lbs.)up t o 2 i n . a n d 1000 f pm f a c e v e l o c i t y

122424242424303642485255

1218243036424854606672

DAMPER WIDTH (in.)

DA

MPER

HEI

GH

T (in.)

122024283337404447515659

242428333944475154606568

302630354247505458647072

362732384550545862687377

423034404753576266727881

483136435056616570778285

543338455359646973818690

603540475662677277859194

182226313640444750566063

Multiply value in Pressure Torque chart by the multiplier listed below to obtain torque for greater design pressure.

PRESSURE TORQUE (in.-lbs.)@ 2 i n . w . g . d i f f e r e n t i a l

3456

1.52

2.53

DIFFERENTIAL PRESSURE MULTIPLIER

Multiply value in Velocity Torque chart by the multiplier listed below to obtain torque for greater design face velocity.

VELOCITY TORQUE (in.-lbs.)@ 1 0 0 0 f p m f a c e v e l o c i t y

1500 2000 2500 3000 3500 4000

2.54

6.259

12.2516

VELOCITY (FPM) MULTIPLIER

68

Page 74: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

DO NOT ADJUST LINKAGE MECHANISM. IF PROBLEM STILL EXISTS AFTER VERIFICATION AND CORRECT ACTION, CALL TAMCO CUSTOMER SERVICE.

T A M C O D A M P E R

INSTALLATION GUIDELINES

•Whenlabelsonbladesareviewedrightsideup,thedamperorientationisFront/Top end up.

•WhenviewedasFront/Topendup,righthand(RH)hasdriverodasshown.Lefthand(LH)hasdriverodonleft.

• Thedamper,asacompleteunit,canbeinstalledrightsideup,upsidedown,standingup,orlyingflat.

• Thereisnospecifiedairentryorairexhaustside.

• Ensurethatdamperisinstalledallowingforfutureaccesstosidelinkage,aswellasdamperjumperbracket,orjackshaft,ifsosupplied.

•Z-platesandfasteners,providedbyTAMCOtointerconnectdampersections,areforalignmentpurposesonlyandmaynotbeconsideredasstructuralsupports.

•Ductworkconstructionandbracingmustbesufficienttosupportdamper.Donotusedampertosquareupduct.Systemmustsupportdamper.Dampercannotsupportsystem.

• Forverticalapplications,thedampermustbeinstalledsothatlinkagefacesupward.Verticallyinstalledsectionsmustbeproperlybracedandsupported.

•A12"-long,hexagonalsteeldriverodisprovidedasstandard.Dampersareshippedwithdriverodinsertedindriveblade.Driverodmaybeextendedupto9"beyondendofthebladebylooseningtheU-bolt,drawingouttherodtodesiredlengthandthenretighteningtheU-bolt.Ifrequired,24"-and36"-longzinc-platedsteeldriverodsareavailable.

FRONT / TOP END UP / RIGHT HAND

FOR TAMCO J ACK SHAFTS AND TAMCO DAMPER JUMPER BRACKE TS , R EFER TO INSTRUCT IONS ON PARTS BOX .

CALL TAMCO CUSTOMER SERVICE WITH ANY QUESTIONS CONCERNING TAMCO DAMPERS1-800-561-3449

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within the printed catalog.

69

Page 75: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

V E R I F Y D A M P E R O P E R A T I O N

BEFORE INSTALLATION

(A) To correctly verify sealing action, loosen hex nuts of U-bolt located on drive blade. Extend steel drive rod to maximum of 9” past frame. Re-tighten hex nuts on U-bolt.

(B) Using drive rod, slowly apply closing torque, while ensuring that damper frame does not twist due to torque being applied. (Larger dampers may require additional person to hold damper frame square and true.)

(C) If possible, use daylight or inside light source as a backdrop to verification procedure. No light should be visible through damper.

CAUTION SHOULD BE EXERCISED TO ENSURE FINGERS ARE NOT IN WAY OF MOVING LINKAGE PARTS OR BLADES.

• Beforeinstalling,inspectdamperforpossibledamagecausedinshipping.

• Ifminordamagehasoccurredtoframecornersorflanges,correctbybendingorhammeringbackintoposition.Ensurecorrectrealignmentofrepair,asbentortwistedframesmightnotmatewithmountingangles,oradditionaldampersections,properly.

• Donotinstalldamperifdamageismorethansuperficial,ifuncertainastoextentofdamage,orifdamperdoesnotsealcorrectly.

Call TAMCO CUSTOMER SERVICE at 1-800-561-3449.

• Operatedampersectionmanually(onaflatsectionoffloor)toverifycorrectblade action and sealing.

I N S T A L L A T I O N O F

DAMPER TYPES

“FLANGED TO DUCT” TYPE

• Dampermustbeinstalledsquare.

• Damperflangeis1”largerthanductallaround.

• Donotassumethatductissquare.Verifythatductflangeissquare,flatandeven.

• Verifythatdamperissquare.Operatedampertoverifyfreemovementofbladesandcorrectsealing.Securedamper.Re-verifythatdamperissquare.

• Repeatprocedureforotherflange,ifductedonbothsides.

• Caulkalljoints.

“INSTALLED IN DUCT” TYPE

• Dampermustbeinstalledsquare.

• Damperapproximately1/2”smallerthanspecifiedductsize.

• Ensurethatductissquareand/orlargeenoughtoallowdampertobeinstalledsquare.

• Makeholeinductwork,ifrequired,toallowextensionofdriverod.

• Bottomofframemustsitflatonfloorofducttopreventtwisting,sagging,orbumpingup,asthis could cause leakage between bottom frame and bottom blade.

• Verifythatdamperissquareandthensecurebottomframetofloorofductusinga90°mountingangle.Operatedampermanuallytoconfirmpropersealing.

• Aseachmountingangleisinstalled,verifyoperationtoensuredamperissealingcorrectly.

• Caulkalljoints.

Linkage Must Be Accessible After Installation

70

Page 76: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

ALL ILLUSTRATIONS SHOWN ARE FRONT/TOP END UP DAMPERS *RH = Right-Hand Damper**LH = Left-Hand Damper

LH

RH

RHRH

LHRH

RHRH

TWO-, THREE-, OR FOUR-SECTION VERTICAL DAMPER

• Installbottomdampersection(s).

• PlaceZ-plate(s)overtopframemember(s).

• PositionendsofZ-plate(s)tolineupwithlengthoftopframemember(s).

• Usingself-drillingscrews,fastenlowerflangeofZ-platetotopframememberthroughpre-punchedholesinZ-plate. (Z-plate not designed to be structural. Additional bracing may be required if deemed necessary by installer.)

• Placesecondlevelofdampersection(s)ontopofZ-plate,andfasten.

• Repeatprocedureforanyadditionalverticalsections.

• Ensureallsectionsarestraight,even,andinlinewitheachother.

SECTIONAL DAMPERSA D D I T I O N A L T O P R E C E D I N G G U I D E L I N E S

FOUR-SECTION HORIZONTAL DAMPER

• Framemembersaredesignedtooverlapandoffertwoalignedpositioningholes.Whendampersarecorrectlypositioned,holeswillbe aligned.

• Alignment fasteners are shipped attached to offset overlapping frame. (Alignment holes are not meant to be structural. Bracing may be deemed necessary by installer.)

• Ensurefoursectionsarestraight,even,andinlinewitheachother.

��

��

LH

RH

RH

RH

TWO-SECTION HORIZONTAL DAMPER

• Framemembersaredesignedtooverlapandoffertwoalignedpositioningholes.Whendampersarecorrectlypositioned,holeswillbealigned.

• Alignmentfastenersareshippedattachedtooffsetoverlappingframe. (Alignment holes are not meant to be structural. Bracing may be deemed necessary by installer.)

• Ensurebothsectionsarestraight,even,andinlinewitheachother.

LH

RH

IF JACK SHAFTS ARE TO BE FITTED, SEE JACK SHAFT INSTRUCTIONS PRIOR TO INSTALLING DAMPERS

71

Page 77: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

MOTOR MOUNTING METHODSF O R E L E C T R I C & P N E U M A T I C A C T U A T O R S

BELIMO ELECTRIC ACTUATOR - DIRECT COUPLED MOUNTING• Motorismountedonamountingbracketattachedtothedamper's4"frame.

BELIMO ELECTRIC ACTUATOR - FACE MOUNTING• Motorismountedonamountingbracket.• Otheraccessoriesrequiredare:TAMCOFaceBladeBracket-2balljoints-pushrodandcrankarm.

BELIMO ELECTRIC ACTUATOR - Jack shaft MOUNTING•Motorismountedonamountingbracket.

ELECTRIC ACTUATORS

PNEUMATIC - DIRECT COUPLED

PNEUMATIC - FACE MOUNTING

PNEUMATIC - Jack shaft MOUNTING

PNEUMATIC ACTUATORS

• Pneumaticmotorsmustbeinstalledandalignedsoastoensureproperrotationofclamporcrankarm.Thisrequirestheactuatortobeinstalledatanangletomatchbladerotation.Damperdriverodmustnotbesubjectedtopressurethatmayboworbendrodoutofline.

• Eachpneumaticactuatorrequiresaccessorieswhicharespecifictoitstype,ormodel,orbrand.TheaccessoriesarenecessarytomountthepneumaticactuatortotheTAMCOdamperhexagonaldriverod,ortotheTAMCOjackshaft.Verify,orconsultwiththeactuatormanufacturerforalistofappropriateaccessories.

• TAMCOcansupplyfacebladebrackets,whichfittheTAMCOdamperU-bolt.Ifafacebladebracketisrequired,itmustbespecified at the time the order is placed.

IN THE CASE OF RETROFIT APPLICATIONS,ACTUATORS MUST BE RELOCATED TO MATCH DAMPER DRIVE BLADE POSITION.

72

Page 78: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S T R U C T U R A L D E S I G N R E Q U I R E M E N T S

FOR MULTI-SECTION DAMPERSREQUIREMENTS:• Intermediate structural support is required to resist applied pressure loads for dampers that consist of two or more sectionsinbothheightandwidth.(Seebelow.)

• Tubularsteelstructuralsupportmayberequiredforlargemulti-sectioneddampers.

MAXIMUM DEFLECTION:• Thestructureprovidingintermediatesupportmustbedesignedtoresistthehighestpressureload,withdeflectionof

less than L/230.Thisapplieswhetherthepressureloadiscreatedbythemechanicalsystem,orbywindload,orifthedamperismountedontheexteriorofthebuilding.

Intermediate structural support required.

DESIGN OF STRUCTURAL SUPPORT FOR TAMCO DAMPERS

��

��

Example:Design the structural support required to carry TAMCO dampers at the 17th story of a building in Ottawa, Ontario, Canada. (Assuming that the maximum internal pressure, as a resultofthemechanicalsystems,is2inchesofwater,10.4psfor500Pa.)

Assumptions:The subject building is 17 floors high and has plan dimension of 120' by 120' (36.6m by 36.6m). The dampers will be mounted on vertical framing members spanning from the 17th floor to the roof slab level.

Analysis: Net wind pressure exterior pressure interior pressure in the mechanical plenum on damper or suction (as specified by the mechanical engineer)

p = qCeCgCp external + 10.4 psf 1997 OCB 4.1.8

Where:p = the specific external pressure acting statically and in a direction normal to the surface, either as a pressure directed towards the surface or as a suction directed away from the surface.

q = the reference velocity pressure based on a 1 in 30 probability of being exceeded in any one year for design of structural members for strength. q1/30 = 7.72 psf(0.37kPainOttawa,Ontario).

Ce = exposure factor based on the height of the building (1.4 for a 170 ft. high building).

Cg = gust factor (2.5 for cladding elements and small structural components). Cp = external pressure coefficient (1.0 for high local suction).

p = qCeCgCp external + 10.4 psf

p = 7.72 psf (1.4) (2.5) (1.0) + 10.4 psf p = 37.4 psf

Total net factored pressure: pf = 1.5 (live wind load) pf=1.5•(37.4) pf = 56.1 psf (2.7 kPa)

Factored distributed load over vertical support framing member: wf = 56.1 psf (5') wf = 281 lb./ft.

Factored maximum moment: Mf = wf l²/8 Mf=281•(10)²/8 Mf = 3513 lb./ft. (4.8kN•m)

= + Resisting moment: Mr has to be equal to or greater than Mf for an unsupported length of 10' (3.05m)

Acceptable vertical support member:

C4 x 6.0 - 4" structural steel channel (metric designation C100 x 9) Mr = 3980 lb.ft. foranunsupportedlength(Lu)=13'. (Mr = 5.4 kNm atLu=4m)

Check deflection criteria:

Maximum allowabledeflectionisL/320=10'/320=0.375"(9.5mm)Maximum deflection at mid-height of the channel:

∆ = 5 w l4 384 E I

For deflection, the reference velocity pressure, q, is based on a 1 in 10 probability of being exceeded in any one year. q1/10 = 6.27 psf (0.30kPain Ottawa, Ontario). p = qCeCgCp external + 10.4 psf p = 6.27 psf (1.4) (2.5) (1.0) + 10.4 psf p = 32.3 psf w = 32.3 psf (5') w = 162 lb./ft.

∆ = 5 (162 lb./ft.) (10')4 384 (29,000 ksi) (4.25 in4)

∆ = 5 (13.5 lb./ft.) (120")4 = 0.30 (7.6mm)

384(29•106 psi) (4.25 in4)

Therefore, an acceptable vertical support member for this example is a C4 x 6.0. (metric designation C100 x 9)

73

Page 79: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

DO NOT ADJUST LINKAGE MECHANISM. IF PROBLEM STILL EXISTS AFTER VERIFICATION AND CORRECT ACTION, CALL TAMCO CUSTOMER SERVICE

1-800-561-3449

(A)• Iflightlinesarepresentacrossfulllengthofblade,checkthatclosingtorquebeingappliedisneithertoolittlenor

too much.

• Under-rotationwillnotletbladegasketscompress,whereasover-rotationcancausebladestore-separate.

(B)• Iflightlinesareobservedonlyalonghalfofbladelength,squareuppositionoftopframemember,relativeto

bottom frame, by pivoting top frame member either in or out.

• A small movement in one of two directions could seal light lines by taking out distortion to frame caused by torque being applied to an unsecured damper.

(C)• Iflightlinesareobservedbetweensideframemembersandbladeendsofadamper,especiallynearcenterline,

verify measurement across damper at top, center, and bottom.

• Ifmeasurementshouldvarybymorethan1/16”,readjustsidemountinganglestobringsideframememberstocorrect dimension, thus matching top and bottom dimensions.

• Iflightlinesdisappear,ensurethatthesematchingdimensionsareretainedwhenfasteningmountinganglesduringinstallation.

(D)• Iflightlinesappearonlyneartopandbottom,onoppositesidesofdamper,betweensideframemembersandblade

ends of a damper, verify square position with tape measure and adjust if required.

• Movetopframemembereitherleftorrighttosquareupdamper.Lightlinesshoulddisappear.

(E)• Ifdamperishardtooperatebyhand,verifythatframesidesarenotsqueezedinortwisted.

• Thiscouldhavetheeffectofincreasingrequiredtorqueorbindingpivotaction.

• Ineithercase,bearinglifecouldbesharplyreduced.

• Verifythatframesidesareparallelbymeasuringacrossdamperatthetop,centerandbottom.

• Alsoverifythatdimensionsonbothsidesofdamperareequal.

(F)• Iflightappearsonlybetweenlastbladeandtoporbottomofdamperframe,itmaybeduetotoporbottomframe

member being distorted (twisted) when fastened to duct work.

• Ensurethattoporbottomframemembersarenotdistortedbylooseningfastenersandshimmingframe,ifrequired.

G U I D E F O R

TROUBLESHOOTING

74

Page 80: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

I N S T A L L A T I O N O F

VERTICAL BLADE DAMPERS

Contact TAMCO Customer Service for configurations not shown.

Service 1-8

00

-56

1-3

44

9

Service 1-8

00-5

61-3

449

ONE-SECTIONVERTICAL BLADE DAMPER

• Single-section vertical blade dampers must be installed so that linkage is at the top.

• The actuator must be mounted on the drive rod which extends beyond the bottom of the damper.

• Thebaseofthedampermustbeextremely well supported.

• Thecustomermustspecifythatthedamper will be installed in a vertical position. Our production software will adjust the configuration automatically.

• There is no predetermined maximum blade length. Contact the factory for details.

• TAMCOwillhonoritswarrantyifalloftheaboveinstructionsareadheredto at the time of order and installation.

TWO-SECTIONVERTICAL BLADE DAMPER

75

Page 81: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

Note: Installation design may require side bracket to be fitted to damper side frame before damper is installed. This could occur due to lack of space between damper frame and duct work needed for fastening hardware tools.

LOCKING COLLAR LOCKING COLLAR

Jack shaft CRANK ARM

SWIVEL (5/16" Ø ROD)

SIDE BRACKET

1" Ø SHAFT

1" Ø RE-GREASABLE BRONZE BEARING

BLADE CRANK ARM

BRIDGE BRACKET

BLADE CLIP

5/16" Ø STEEL CONNECTING ROD

I N S T A L L A T I O N G U I D E L I N E S

TAMCO JACK SHAFTS

•EnsureinstalleddampersectionsconformtoTAMCO Aluminum Damper Installation Guidelines, which are included with shipment.

•Dampermountinganglesshouldbesizedtoallowsidebracket to sit directly on damper frame.

•Loosen1"diametercollarsonshafttoallowstress-freealignment upon installation.

•Jackshaftcanbemountedsoastodriveatwo(2)sectiondamper from either left, or right side.

•Ifassistanceisrequired,call TAMCO CUSTOMER SERVICE 1-800-561-3449

C H E C K L I S T

BEFORE INSTALLATION

•Placecompletejackshaftondamper.Attachsideandbridgebrackets on pre-drilled damper frames using ¼" hardware provided.

(If required, remove jack shaft crank arm to allow shaft to fit through duct work.)

•Slideactuatorendofjackshafttorequireddimension.Ensurethatopposite end of jack shaft ends beyond last blade clip.

(Refer to drawing for position and alignment of connecting rod.)•Positionandtighten1"diametercollarsclosetobearings,to

prevent jack shaft from shifting sideways.•Ifrequired,loosenbladecrankarmsandrealignwithfactory-

installed blade clips on damper blades. Re-tighten blade crank arm fasteners.

(Ensure that both blade crank arms are aligned with each other.)•Insertfreeendof5/16" diameter connecting rods into swivel of

blade crank arms. Position blade crank arms at 45°, downwards and away from closed damper. Tighten swivels to connecting rods.

(Refer to drawing for position of blade crank arms.)•Cyclethedampermanuallyandensurethatbothsectionsseal

correctly.•Ifadjustmentisrequired,re-positionconnectingrodinbladecrank

arm swivel so as to allow both sections to close fully.•Re-tightenswivelandverifydamperclosure.•Repeatadjustmentprocedureifnecessary.

J A C K S H A F T

INSTALLATION PROCEDURE

In fully closed position, the crank arm is to be at a 45° angle, as shown.

76

Page 82: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

I N S T A L L A T I O N G U I D E L I N E S

VERTICAL JACK SHAFTS

•Ensurethatthedampersectionsandthehorizontaljackshafts are properly installed. (See TAMCO Aluminum Damper Installation Guidelines and Installation Guidelines for Horizontal Jack shafts.)

•Withthedampersectionsclosed,positionbothpre-installedshort jack shaft crank arms at a 45° up angle and align them with each other. (Refer to the accompanying drawing.)

•Inserttheverticaljackshaft’s5/16" diameter rod cap ends into the short jack shaft crank arm swivels. Ensuring that the damper sections are fully closed, tighten the set screws.

•Ifanyadjustmentisrequired,repositiontherodcapendinthesort jack shaft crank arm swivel until both sections close fully.

•Retightentheswivelandverifydamperclosure.•Repeattheadjustmentprocedureifnecessary.•Ifassistanceisrequired,call TAMCO CUSTOMER SERVICE 1-800-561-3449.

V E R T I C A L J A C K S H A F T

CONNECTED TO HORIZONTAL JACK SHAFT

•Ensuredampersectionsareproperlyinstalled.(SeeTAMCOAluminum Damper Installation Guidelines.)

•Loosenthefacebladebracketswivelfastenertoallowtheremoval of the face blade bracket from the ¼" end rods.

•Withbothdampersectionsclosed,undothehexnutsonthe drive blade U-bolts. Position the face blade bracket over the U-bolt (with the swivel at the top) and secure the bracket with the hex nuts. (For Series 9000 dampers, retain the spacing plate located in the blade channel.)

•Insert the vertical jack shaft's 5/16" diameter rod cap ends into the face blade bracket swivels. Ensuring that the damper sections are fully closed, tighten the set screws.

•Ifanyadjustmentisrequired,repositiontherodcapendinthe face blade bracket swivel until both sections close fully.

•Retightentheswivelandverifydamperclosure.

•Repeattheadjustmentprocedureifnecessary.

•Ifassistanceisrequired,call TAMCO CUSTOMER SERVICE 1-800-561-3449.

V E R T I C A L J A C K S H A F T

CONNECTED TO FACE BLADE BRACKETS

Swivel

Left- and right-handface blade bracketsShort

jack shaft crank arm

Note:Installationdesignmayrequireverticaljackshafttobeinstalledalongwithastandardjackshaft.PleaserefertoTAMCOJackShaftInstallationGuidelinesforinstallationinstructionsspecifictostandardjackshaft.

77

Page 83: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

I N S T A L L A T I O N G U I D E L I N E S

TAMCO DAMPER JUMPERSNote: Damperjumpersaresuppliedregardlessofthenumberofmotorsspecified.Ifajumperisfitted

and two motors are to be utilized, the failure of one motor may prevent the remaining motor from operating both damper sections correctly, or prevent operation entirely.

Jumper ready to mount to U-bolts located on the drive blades.

LEFT SIDE BRACKET

RIGHT SIDE BRACKET

HEX WASHER HEAD CAP SCREWS FLANGED NUT

•Ensurethattheinstalleddampersectionsconformto TAMCO Aluminum Damper Installation Guidelines, which are included with shipment.

•Manuallyensurethatthedampersectionsoperatefreely and easily, before installing damper jumpers.

•Ifanyassistanceisrequired,call: TAMCO CUSTOMER SERVICE 1-800-561-3449.

V E R I F Y D A M P E R O P E R A T I O N

BEFORE INSTALLATION

•LoosenandremovethehexnutsfromtheU-boltsonbothdriveblades. (Take care that the U-bolt does not drop out if the damper is installed horizontally.)•Installthedamperjumperasshownonthedrawings.Then,replaceandtightenthehexnuts. (Insulated dampers must retain the rectangular spacer between the jumper and the blade.)•Cyclethedampermanuallyandensurethatbothsectionssealcorrectly. (Operate by driving the section which is to be directly connected to the motor.)•Ifanyadjustmentisrequired,loosenbothflangednutsandoffsetthehalvesofthe

jumper so as to allow the section with the actuator to close fully last.•Re-tightentheflangednutsandverifydamperclosure.•Repeattheadjustmentprocedureifnecessary.

D A M P E R J U M P E R

INSTALLATION PROCEDURE

Jumper halvescan be offset foradjustment purposes.

78

Page 84: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S E R I E S 1 0 0 0 / 1 5 0 0 / 9 0 0 0

LINEARITY INFORMATION

For two-position or shut-off applications, where dampers are always either fully open or fully closed, flow control characteristics are largely irrelevant. Shut-off dampers should be selected and sized to minimize pressure drop in the full open position, and to minimize air leakage and maximize thermal performance in the closed position. TAMCO Dampers are ideal in these applications.

For applications where dampers are used to control flow over a range of air flows, it is necessary to size the dampers based on the pressure drop of the damper in differentpositions,theresistanceoftheduct’ssystemthatthe damper affects, and the characteristics of the control signal. The interactions between a flow control damper, the system in which it is installed, and the controls can be complex. It is critical for proper control and efficient system operation, that known and controllable factors be optimized. To this end, most control system manufacturers have developed sizing guidelines. We recommend that the detailed sizing procedures provided by control manufacturers and ASHRAE, be used for sizing dampers, especially in complex or critical applications. The following sections provide information on the characteristics of TAMCO dampers to be used in these design methods and also provides some further general sizing guidelines that may be appropriate in simple systems.

100

90

80

70

60

50

40

30

20

10

00 15

% F

low

Blade Angle

Figure 2Characteristic Curve for Opposed Blade Dampers

30 45 60 75 90

TAMCO Manufacturer A Manufacturer B Manufacturer C

100

90

80

70

60

50

40

30

20

10

00 15

% d

ébit d

'air

Figure 2Courbe caractéristique pour volets à lames opposées

30 45 60 75 90

TAMCO Manufacturier A Manufacturier B Manufacturier C

Angle de rotation (lame)

100

90

80

70

60

50

40

30

20

10

00 15

% F

low

Blade Angle

Figure 1Characteristic Curve for Parallel Blade Dampers

30 45 60 75 90

TAMCO Manufacturer A Manufacturer B Manufacturer C

100

90

80

70

60

50

40

30

20

10

00 15

% d

ébit d

'air

Figure 1Courbe caractéristique pour volets à lames parallèles

30 45 60 75 90

TAMCO Manufacturier A Manufacturier B Manufacturier C

Angle de rotation (lame)

S I Z I N G

FLOW CONTROL DAMPERS

The pressure drop and flow of TAMCO Series 1000, 1500, & 9000 dampers were tested to AMCA Standard 500-89 at blade angles of 15, 30, 45, 60, 75 and 90 degrees.

The results confirmed that the performance characteristics (linearity curves) of TAMCO Series 1000, 1500, and 9000 dampers are comparable to the assumptions used by major control system manufacturers and the ASHRAE handbooks.

Figures 1 and 2 show the tested “characteristic curves” for parallel and opposed blade TAMCO dampers, and com-pare them to other published data.

F L O W C H A R A C T E R I S T I C S

T A M C O D A M P E R S

79

Page 85: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 1 0 0 0 / 1 5 0 0 / 9 0 0 0

GENERAL SIZING GUIDELINESEven for general sizing guidelines, one must understand the term "Damper Authority", which is defined as the following ratio:

pressure drop across a control damper in the full open position

total pressure drop of the portion of the system that the damper controls.

(Note that some manufacturers refer to characteristic ratios instead of damper authority. This is the ratio of the “series” resistance to damper resistance, where series resistance is the total system resistance less damper resistance.)

The characteristic curves shown in Figures 1 and 2 correspond to the 100% authority curve, where the entire pressure drop of the system occurs across the damper. As can be seen, this curve is not linear. As Damper Authority decreases (system pressure drop excluding the damper goes up), the shape of the flow versus blade angle curve changes. A family of curves can be plotted as in Figures 3 and 4, showing damper performance at various values of Damper Authority.In most, but not all, flow control applications, a linear performance is desired. Proper sizing of the damper will result in economical damper selections, with performance close to linear. System characteristics, as well as damper characteristics, must be addressed.Two approaches can be taken to size control dampers correctly. The first method, often used by system designers, is iterative. The designer selects an arbitrary damper size, often the full dimension of the duct, determines pressure drop across the damper at full flow from manufacturer selection charts,anddoesa“checkcalculation”fordamperauthority.Iftheresultindicates that the damper authority is insufficient for the application, smaller dampers are selected until required authority is achieved.The second method consists of calculating the desired pressure drop across the damper at full flow, using the appropriate authority values and calculated duct system pressure losses. The procedure is:•Calculatetheductsystempressurelossatfullflow,excludingthecontroldamperloss,whichisstillunknown.•Selectthedamperauthorityrequiredtoprovidethedesiredcontrolcharacteristics.•Calculate the control damper pressure loss at full flow: PD = (DA / (100 - DA) x PS where PD = damper pressure drop at full flow / DA = damper authority, selected by designer / PS = duct system pressure loss, calculated using standard methods.

•Selectdampersizesfromthecalculatedrequiredpressuredrop,PD,andmanufacturer’sselectioncharts.

When air flow must be controlled in direct proportion to a control signal, a linear performance characteristic is desirable. A typical application is throttling air flow to maintain a space temperature, such as with a VAV box. Referring to the authority curves, it is apparent that a parallel blade damper should be selected to have an authority of approximately 20% to 25%, and for an opposed blade damper, approximately 8% to 10%. An example using TAMCO selection charts is provided below.

Example of damper sizing for linear performanceAssumptions: Sizing Series 1000/1500/9000 dampers for linear performance in a system with a duct system (series) pressure drop, excluding damper, of 0.2 inches w.g. at full flow of 5000 cfm.

0

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50 60 70 80 90 0

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50 60 70 80 90

% fl

ot

d'a

ir m

ax

imum

Degré d'ouverture des lames

Signal de contrôle

Figure 3Caractéristiques de débit pour volet à lames parallèlles

% M

ax

imum

Flo

w

Damper Position Degrees Open

Control Signal

Caractéristiques des flots d'air à différentes «autorité de volet» (1-100%)

Installed flow characteristics at different damper authorities (1-100%)

Figure 3Parallel Blade Damper Flow Characteristics

32 4 5 6 7 8 9 10V

1%

2%

3%

4% 5%

10%

15%

30%

20%

50%

100%

1%

2%

3%

4% 5%

10%

15%

30%

20%

50%

100%

32 4 5 6 7 8 9 10V

0

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50 60 70 80 90 0

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50 60 70 80 90

% M

ax

imum

Flo

w

Damper Position Degrees Open

Control Signal

Installed flow characteristics at different damper authorities (1-100%)

Figure 4Opposed Blade Damper Flow Characteristics

% fl

ot

d'a

ir m

ax

imum

Degré d'ouverture des lames

Signal de contrôle

Figure 4Caractéristiques de débit pour volet à lames opposées

Caractéristiques des flots d'air à différentes «autorité de volet» (1-100%)

100%

50%

30%20%

15%10

%5%4%3%

2%1%

100%

50%30%

20%15

%10%

5%4%3%

2%1%

32 4 5 6 7 8 9 10V 32 4 5 6 7 8 9 10V

Damper Type 1000 PB 1000 OB Desired Damper Authority (DA) % 20% 10%

Desired Damper Pressure Drop = 20/80 x 0.2 = 10/90 x 0.2 = DA/(100-DA) x series pressure drop = 0.050 = 0.022

Area Factor from Pressure Drop Selection Chart 0.2 0.08

Possible sizes 12” x 48” 16” x 56” 16” x 36” 20” x 44” 20” x 28” 24” x 24”

80

Page 86: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

S I Z I N G C R I T E R I A

OTHER CASES

MIXED-AIR CONTROL

A typical application is the economizer section in an air handling system, where two air streams are mixed to maintain a fixed temperature set point. To achieve stable and predictable static pressures and improved energy efficiency and comfort, the dampers should be sized so that the total flow rate of the system remains constant. This is generally best achieved by selecting dampers that are sized to provide linear performance in the range of interest. For dampers in ducted systems, this usually requires that the outside air, return air, and exhaust dampers all be selected with similar authority, in the order of 8% to 10% for opposed blade dampers, or 20% to 25% for parallel blade dampers. However, in many cases, the outside air damper is installed behind the intake louver and is the same size as the louver in an effort to reduce entry of snow and rain. This results in grossly oversized dampers. In this case, size the outside and exhaust dampers with the same authority. Opinions differ on sizing the return damper in this situation. A general guideline would be to select a parallel blade damper with a pressure drop similar to the pressure difference between the inlet and exhaust ducts at the return duct takeoff. The outside and exhaust dampers should be of the opposed blade type.

FACE & BYPASS CONTROL

For face and bypass applications, the pressure drop through both sections should be the same. Size the bypass damper so that the pressure drop is the total of coil plus coil damper pressure drops.

PRESSURE CONTROL

This application is no longer common since the advent of cost-effective variable-speed drives and fan inlet vanes. Both are more energy efficient and should be considered over damper control for these applications.

81

Page 87: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

S E R I E S 1 0 0 0 & 1 5 0 0

SOUND RATINGSNOTE: Tested dampers are “Flanged to Duct” type. See Air-Foil Control Damper Specifications sheet

for mounting types.

Noise Criteria (NC) ratings were determined by subtracting 10dB (room effect) from the Sound Power Levels.When comparing NC numbers with those supplied by other damper manufacturers, ensure that only 10dB for room effect has

been subtracted. Further subtraction of another 10dB for room attenuation will result in false field readings.

blade action CFM NC CFM NC CFM NC CFM NC

Damper Size Full Open 75% Open 50% Open 25% Open

12” x 12” 1000 22 500 21 200 20 100 19 opposed blade 1500 32 700 32 350 35 175 34 2200 43 1000 41 500 45 245 43

12” x 12” 1000 27 1000 30 600 37 300 31 parallel blade 1500 38 1400 40 800 38 375 34 2200 46 1700 51 1075 47 500 45

18” x 18” 2550 24 1900 34 600 24 250 30 opposed blade 3800 37 2530 42 800 33 300 34 4750 43 3150 47 1000 40 400 42

18” x 18” 2150 19 1400 20 890 21 500 22 parallel blade 3550 34 2150 35 1330 37 700 33 5000 53 2850 72 1780 43 890 41

24” x 24” 4000 25 3000 35 1500 37 500 46 opposed blade 8000 44 4000 42 2000 49 750 51 10000 49 6000 57 3000 63 1000 59

24” x 24” 4000 23 6000 24 2000 32 1000 27 parallel blade 8000 43 6000 47 4000 48 2000 50 10000 48 8000 52 5000 54 3000 62

blade action CFM RC CFM RC CFM RC CFM RC

Damper Size Full Open 75% Open 50% Open 25% Open

12” x 12” 1000 27 500 27 200 27 100 27 opposed blade 1500 34 700 35 350 39 175 38 2200 47 1000 45 500 19 245 51

12” x 12” 1000 27 1000 30 600 32 300 31 parallel blade 1500 38 1400 42 800 38 375 37 2200 49 1700 52 1075 47 500 45

18” x 18” 2550 27 1900 26 600 28 250 30 opposed blade 3800 41 2530 45 800 37 300 34 4750 48 3150 54 1000 44 400 45

18” x 18” 2150 22 1400 26 890 26 500 26 parallel blade 3550 37 2150 35 1300 36 700 35 5000 48 2850 43 1780 44 890 43

24” x 24” 4000 27 3000 37 1500 40 500 54 opposed blade 8000 48 4000 45 2000 48 750 58 10000 53 6000 55 3000 61 1000 64

24” x 24” 4000 25 3000 27 2000 32 1000 27 parallel blade 8000 46 6000 48 4000 49 2000 48 10000 53 8000 53 5000 53 3000 58

NOISE CRITERIA RATINGSNC ratings published above for use with NC curves (ASHRAE 1993 Fundamentals

Handbook: Chapter 7). NC curves define limits that octave-band spectrum of a noise source must not exceed to achieve a level of occupant acceptance.

ROOM CRITERIA RATINGSRC ratings published below for use with RC curves (ASHRAE 1993 Fundamentals Handbook:

Chapter 7). RC curves, for specifying design level in terms of a balanced spectrum shape, are designed especially for establishing HVAC system design goals.

82

Page 88: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

RICHARD J. DALEY CENTERMr. Dan Romero, Chief Engineer at the Richard J. Daley Center, Chicago, headed the project to retrofit one of the key systems in this building. The primary requirement was to find a low-leakage, maintenance-free damper product that could withstand 9 inches of static pressure.

A meeting between Stern Mechanical, Mr. Romero and Mr. Jim Karambelas was instrumental in developing a plan for TAMCO to supply more than 2,700 square feet of dampers for this job. The damper selected was the Series 1500 (AMCA certified at 1.7 cfm/sq.ft. at 1 inch of static pressure). The application also called for the use of specially designed, TAMCO horizontal and vertical jack-shafts. Pneumatic actuators were used in a tandem position, as shown in the picture on the right.

MB Real Estate was so pleased with TAMCO’sproductandservicethattheyare proceeding with replacing existing dampers with TAMCO dampers for the rest of this project.

The TAMCO Series 1500 was specified for this entire project. The contract was secured as a result of the solid representationofTAMCO’sinnovativedamperssolutionsby E.I.P. to E.S.D. Engineering. Johnson Controls purchased more than 3,100 square feet of TAMCO’s dampers, toinstall at One North Wacker Drive, Chicago.

F. E. Moran was the mechanical contractor on this project. Mr. Ed Walsh, Chief Engineer at the John Buck Company (general contractor), was very impressed with the quality of the product and service obtained from both E.I.P. and TAMCO.

ONE NORTH WACKER DRIVE

TAMCO SUCCESS STORIES

Page 89: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

Note that all technical information available on TAMCO’s web site at www.tamco.ca supersedes and takes precedence over all information contained within this catalog.

Indiana University & Purdue University Indianapolis (IUPUI) chose TAMCO dampers to replace all of the existing dampers in the Business Spea Building, in Cavanaugh Hall and in the University Library. In total, over 600 square feet of TAMCO Series 9000 Thermally Insulated Dampers, Series 9000 SC Severe Cold Option Dampers and Series 1500 Ultra-low Leakage Dampers were installed. TAMCO dampers were used to replace old dampers that had failed due to freeze-up and wear over the years.

This project was secured by Keller-Rivest, the exclusive distributor for TAMCO products in Indiana. Mr. Frank Haag, of Keller-Rivest, met with the engineering staff at IUPUI. He offered the university a free damper which was used as a replacement on an air handling unit. The engineers were extremely impressed with the performance of the TAMCO damper. Following this initial testing, the engineers presented the TAMCO damper to the University architects, who approved the dampers and have listed TAMCO as standard in their specifications ever since.

Mr. David Pfeifer (Energy Systems Project Manager - Campus Facility Services) stated that the TAMCO insulated dampers were installed in all outside air applications, because they are the optimal solution in cold winter conditions. “They have good insulation value and good weather seals...they protect coils against freeze-up.” IUPUI selected Series 1500 dampers for all their return and exhaust air applications.

TAMCO GOES TO SCHOOLTheir ultra-low leakage rate makes them ideally suited to these applications, while providing a means of cost control on a damper replacement project of this size.

Mr. Pfeifer indicates that one of the key selling features of TAMCO dampers is “...they came straight from the factory more square than those of other damper manufacturers.”

Mr. Pfeifer also lists the robust jack shafts and weather-tight seals as other selling points. “We have used all of the accessories and have been impressed with their performance.”

IUPUI has found that the installation of TAMCO dampers is easier, because of the one-inch wide flanges which provide a flat surface to insert screws. They also preferred TAMCO dampers because “Z” plates are provided with all multi-section dampers and holes are pre-drilled for jack shafts.

The engineers and project managers at IUPUI have been very impressed with the reliability of TAMCO dampers. Mr. Pfeifer says, “The TAMCO dampers have been installed at the university for over two and half years and have not needed any maintenance, and they still perform like new! The university has replaced three buildings completely with TAMCO dampers and three new buildings will have TAMCO dampers in all the air handlers when we finish.”

“...TAMCO dampers have been installed at the university for over two and half years and have not needed any maintenance, and they still perform like new!”

Page 90: - Air Movement and Control Association · TAMCO DAMPER OPTIONS Face & Bypass Option for Series 1500, 1500 SW, 1000 & 1000 SW 55 Face & Bypass Standard Configurations 56 Square-to-Round

DISTRIBUTION NETWORK ACROSS NORTH AMERICA

TAMCO has developed a comprehensive network of distributor representatives, which covers all major Canadian urban centers. TAMCO has also established a solid and continually expanding distribution network across the United States.

VisitTAMCO’swebsiteforournewestupdatesortofindthename of the TAMCO representative nearest you.

www.tamco.caTo contact TAMCO Customer Service, dial

1-800-561-3449or e-mail: [email protected]

27 Iber Road, Stittsville, Ontario, Canada, K2S 1E6

CUSTOMER SERVICE

• TAMCOprovidesinstallationguidelines with every order.

• Before- and after-sales technical support and service are available.

• TAMCOproductsandpersonnelareyourguarantee of total performance.

• TAMCO’stop priority is total commitment to your satisfaction with our products and service.

TAMCO MAY 2008 / PRINTED IN CANADA