    Building Pathology and

    Diagnostic

    Building Pathology and diagnostic

    Homework 3

    Homework 4

    Serkan cakIr

    736742

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    2/14

    Building Pathology and

    Diagnostic

    This Building is located close to

    the central station.There is a police

    station at the opposite side.The

    building is located between two

    buldings.

    Central Station

    Via Giovanni Schiparelli

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    3/14

    Building Pathology and

    Diagnostic

    Front Side of building looked

    in direction of Nort-east)

    Backside of building looked

    in direction of South-west)

    As the building having 4 floor,the

    first floor is used as commercial.The

    rest ones are used as residential .

    On the facade of frontside ,there

    are some anomalies as seen fromthe picture(Loss of

    Mass,Scaling,Encrustration...This

    front facade is subjected to lots

    anomalies in comparison with back

    side.

    As seen from the picture,this facadeis quite seen in good

    condition.Because of the facade

    seeing the closed area of which is

    not affected with weathering as

    much as opposite site of facade.

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    4/14

    Building Pathology and

    Diagnostic

    Front Elevation

    Survey

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    5/14

    Building Pathology and

    Diagnostic

    Front Elevation

    Survey

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    6/14

    Building Pathology and

    Diagnostic

    Backside Elevation

    Survey

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    7/14

    Building Pathology and

    Diagnostic

    Backside Elevation

    Survey

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    8/14

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    9/14

    Building Pathology and

    Diagnostic

    1) Loss of Mass

    a)Crumbling

    Crumbling is the loss of internal coherence and loss of material.

    As you see from the pictures taken from surface,some crumbling

    effects are severly than rest of them.This anomaly depends

    upon also where it happens.According to the pictures,thecrumbling formed on the upper part of facade is subjected to

    medium effect,but instead the crumbling formed on the first

    floor subjected to severely effect.The most affected part could

    have been subjected to more water effects(rain..), or by the

    action of human effects..

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    10/14

    Building Pathology and

    Diagnostic

    b)Scaling

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    11/14

    Building Pathology and

    Diagnostic

    1) Loss of Mass

    a)Scaling

    Scaling is local flaking or peeling away of the near-surface

    portion of hardened concerete or mortar.The reason to make

    scaling occur could be freeze-thaw attack or salt attack.From the

    pictures shown on the previous page one part is especiallyundergone much suffering.Maybe the problem could be

    enlightened analyzing that wall in depth.

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    12/14

    Building Pathology and

    Diagnostic

    2)Chromatic/Texture Alteration

    Deposit

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    13/14

  • 7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4

    14/14

    Building Pathology and

    Diagnostic

    Freeze&

    Thaw

    Salt

    Attack

    Salt

    Exposure

    Rain

    Not to be

    compliance with

    the design rules to

    product concrete

    High W.C

    ratio

    Capilarity

    Action

    Indirect

    Action

    GroundWater

    Having

    unsuccifient

    Drenaige system

    Early

    Finishing

    Failure

    Alteration

    Process

    Defect&

    Action

    Error/

    Omission

    A

    A

    Cylic

    Deformation

    Water Exposure

    Scaling

    Quality of

    Concrete

    Quality of

    Concrete

    Bounced

    water

    From

    the air

    Through

    fromthe rain

    Direct

    Action