-w ilhelm conrad roentgen-1895 -e lectrical discharges in a vacuum tube -c aused a phosphoric screen...
TRANSCRIPT
![Page 1: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/1.jpg)
![Page 2: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/2.jpg)
-Wilhelm Conrad Roentgen-1895
-Electrical discharges in a vacuum tube
-Caused a phosphoric screen to fluoresce
-Formed an image of bone
-First x-ray photograph of wife’s hand/ring
![Page 3: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/3.jpg)
![Page 4: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/4.jpg)
One year later British doctors were already using x-ray imaging.
Prolonged exposure to x-rays caused tissue burns.
Wounds were abnormal- took time before appearing.
![Page 5: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/5.jpg)
![Page 6: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/6.jpg)
-The energy of a light-wave is carried by packets called
photons
-The energy of a photon depends on the light’s
wavelength
-Smaller wavelengths have larger energies
![Page 7: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/7.jpg)
1 eV = 1.602x10-19 Joules
Need 56,000,000,000, 000,000,000,000 eV to
cook an egg.
Photon energies are usually given in units of electron
volts (eV)
![Page 8: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/8.jpg)
![Page 9: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/9.jpg)
![Page 10: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/10.jpg)
![Page 11: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/11.jpg)
X-ray tube consists of the following major parts1- Filament: made from tungsten wire which is heated
electrically at a potential difference of 8 to 12 V to a high temperature so that electrons ‘boiled off’ from its surface. These electrons form the tube beam.
The filament is located within a negatively charged nickel cathode which is shaped so that a precise beam geometry is obtained.
![Page 12: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/12.jpg)
2- Cathode: this houses the filament and is manufactured from nickel . The filament is located within a cup having sharp contoured edges which electrostatically focus the electron beam.
The cathode cup is independently supplied with a high negative voltage
3- Anode: is manufacture from tungsten (high melting metal). Dental units and small mobile X-ray units use stationary or fixed anode design. The most efficient design however uses a rotating-disk anode which enables higher X-ray output owing to more effective cooling.
![Page 13: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/13.jpg)
![Page 14: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/14.jpg)
![Page 15: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/15.jpg)
![Page 16: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/16.jpg)
X-ray Image
Two Forks,
Ball pin,
and teeth brush in
the intestine
![Page 17: -W ilhelm Conrad Roentgen-1895 -E lectrical discharges in a vacuum tube -C aused a phosphoric screen to fluoresce -F ormed an image of bone -F irst x-ray](https://reader036.vdocument.in/reader036/viewer/2022070305/55143caf5503466d1a8b55b2/html5/thumbnails/17.jpg)