Page 1: 002. as Micromax-soc Bs

Introduction to AS MicroMAX-SOC

Connecting The World

Page 2: 002. as Micromax-soc Bs

24 October 20062

WiMAX Product Portfolio – A Microcellular Solution

MicroMAX-SOC Bstn.

Reference: 605-0000-741 & 742 MicroMAX-SOC Overview and HW Installation

Page 3: 002. as Micromax-soc Bs

24 October 20063

Full WiMAX SolutionFull WiMAX Solution

IP CoreNetwork

PSTN / Voice Network

V5.2 or GR.303

IP

Softswitch

IP or E1

IP Backhaul

Macro/HiperMAX

MicroMax-SOC

EasyST

ProST

SIP orMGCP

Microcell

MacrocellIP Backhaul

ProST

Page 4: 002. as Micromax-soc Bs

24 October 20064

MicroMAX-SOC SiteMicroMAX-SOC Site

Base Station with one layer of BSRs

The MicroMAX-SOC is a stand-alone Base Station combining Antenna, Radio & Base-band Modem in a single Enclosure.

Page 5: 002. as Micromax-soc Bs

24 October 20065

Main Features Main Features

• Outdoor unit (ODU):– MicroMAX-SOC Base Station Radio (BSR)

• Indoor unit (IDU):– SDA-4S Type-II: small low cost IDU with built in LAN

– SDA-4SDC Type-II: small low cost DC IDU with built in LAN switch

• IDU/ODU connectivity:– CAT 5e (24 gauge or better) cable (22 Recommended)

– Fast Ethernet: 4 pins

– -48v DC power: 2 pins

– For BSR FDD up to 100 meters

• Minimum configuration:– SDA-4S Type-II and a single BSR

• Larger configurations:– N * SDA-4Ss and N*BSRs

BSR

SDA-4S

Smallest BS

Page 6: 002. as Micromax-soc Bs

24 October 20066

Why MicroMAX-SOC?Why MicroMAX-SOC?

• Based on the latest wireless technology ( )

• ‘Pay as you GROW’– Low entry price

– Ideal for rural and CCTV applications

– Ideal to provide ADSL / CATV complementary services

• Full flexibility for the operator:– BSR redundancy

– SDA redundancy

– Using different types of sectors (60 degree, 120 degree, 360 degrees etc)

Page 7: 002. as Micromax-soc Bs

24 October 20067

MicroMAX-SOC uses SequansMicroMAX-SOC uses Sequans

• Based on Sequans System on a Chipset (SOC)

• Can support up to 28 MHz channels (full duplex)

• Potential for growth

• SOC initially optimised for IEEE802.16-2004

– 2nd phase will include an optimised 16e

• SOC engine enables the MicroMAX-SOC to provide best cost/performance

Page 8: 002. as Micromax-soc Bs

24 October 20068

MicroMAX-SOC Key FeaturesMicroMAX-SOC Key Features

• Integrated antennas:– Encased ODU with Integral antenna

– Typically 60 degree antenna

– Low cost and easy installation

• External antennas:– Third-party High gain antennas

– Sectorisation:

• 30, 60 (High gain),

• 90, 120, 180, 360 (0mni)

• SNMP management (Netspan)

• WEB management

• Configuration File

• RF Band:– 3. 5 GHz FDD (Full Duplex!)

– Tx power in 64QAM3/4: 27 dBm in 3.X GHz

• Based on:– Field proven mechanics / physical

design

– Sequans chipset

• ODU– Powered from indoor SDA

NOTE: An SOC with an “N”

type port for a third-party external antenna does not provide a built-in antenna

Page 9: 002. as Micromax-soc Bs

24 October 20069

Features & CapabilitiesFeatures & Capabilities

• The BSR supports a variety of features and capabilities that are defined as mandatory or optional

– Adaptive Modulation and FEC – 7 Burst Profiles• 64QAM 3/4, 64 QAM 2/3, 16 QAM 3/4, 16 QAM 1/2, QPSK 3/4, QPSK 1/2, BPSK 1/2

– Spectrum: 3.4 – 3.6 GHz, 3.5 / 1.75 MHz channels• 3.5GHz FDD Low (3.5F1) UL 3400 to 3452MHz

• 3.5GHz FDD High (3.5F1) UL 3450 to 3500MHz

– Security• DES encryption (3-DES for keys)

• AES encryption (Roadmap)

– Uplink Sub Channelisation

– Packing and Packet Header Suppression (PHS)

– PMP: up to 256 CPEs per BSR

– Networking:• Transparent Bridging – 4,000 entries in LAN tables of BSR

• VLAN tagging/un-tagging – up to 512 VLANs – currently VLAN pass through supported only. (Rel.3.0 will provide additional support)

Page 10: 002. as Micromax-soc Bs

24 October 200610

Features & Capabilities (Contd.)Features & Capabilities (Contd.)

• QoS and Bandwidth Management– Packet Classification – Based On:

• Source/Destination IP Addresses

• Source/Destination MAC Addresses

• Protocols and Applications

• 802.1Q/p, DiffServ/TOS

– nrtPS, BE – as defined by IEEE802.16-2004

– UGS, rtPS – (Not currently supported)

– CIR / MIR

– CIR Proportional Degradation:

• In case of CIR overbooking each CPE gets k*CIR (k is overbooking factor)

• FDD Full Duplex BTS– Full Duplex BSR

– Half Duplex SS

• Dynamic Frequency Selection - DFS

Page 11: 002. as Micromax-soc Bs

24 October 200611

BSR Redundancy – Using SDA-4SBSR Redundancy – Using SDA-4S

BSRs with different channels cover the same / overlapping areasIn case BSR or link to BSR drops – the other BSR will be used Load sharing – all BSRs are active

FailedBSR

SDA

ProST

ProST

SDA

“Standby” BSR

EasyST

SDA-4S

IP Router

X

IP Network

Page 12: 002. as Micromax-soc Bs

24 October 200612

Base Station ConnectionsBase Station Connections

Interface Role

DB 15

IDU/ODU interface:

Fast Ethernet from/to SDA-4S

Power from SDA-4S

DB9 Fault finding / Debug Use Only

RJ45 (with a cover) For future use

N Type RF connector – in one of the variants

For connectivity of an external antenna

BSR has two variants:

With an integrated 60 degree antenna

Or

With an N type connector for external antenna

This connector will not be fitted on an Integral Antenna Unit

Page 13: 002. as Micromax-soc Bs

24 October 200613

SDA-4S & SDA-4SDC Type IISDA-4S & SDA-4SDC Type II

• Small Data Adaptor – Four Switch

• Serves as IDU for BSR or ProST

• Provides power to:

• BSR – MicroMAX-SOC

• SS – ProST / ProST WiFi

• 4 x 100BaseT Ethernet ports

Uplink Indication

Page 14: 002. as Micromax-soc Bs

24 October 200614

Connecting BSR to SDA-4S Type IIConnecting BSR to SDA-4S Type II

Cat 5 Ethernet (Straight) cable

• 1. Orange/White

• 2. Orange

• 3. Green/White

• 4. Blue

• 5. Blue/White

• 6. Green

• 7. & 8. NOT USED

Page 15: 002. as Micromax-soc Bs

24 October 200615

Connector PinoutsConnector Pinouts

IMPORTANT NOTE:

Pins 7 and 8 are Not Connected

Page 16: 002. as Micromax-soc Bs

24 October 200616

Lightning & Surge ProtectionLightning & Surge ProtectionTo MicroMAX-SOC

To SDA-4S

• The Optional third-party Lightning / Surge Protector (Polyphaser) is required in certain situations:

– ODU to IDU cable length of 40 metres or more (Mandatory)

– Geographical areas which suffer Severe lightning storms

• Installed outdoors on the Cat 5e cable

Page 17: 002. as Micromax-soc Bs

24 October 200617

Physical Installation Physical Installation

To Install follow the instructions in the Hardware Installation Manual –

605-0000-742 (currently Rev.E)

Page 18: 002. as Micromax-soc Bs

24 October 200618

Positioning of MicroMAX-SOCPositioning of MicroMAX-SOC

MicroMAX-SOC positioning is obtained in two planes by adjustment of the mounting bracket as shown above.

Page 19: 002. as Micromax-soc Bs

24 October 200619

WiMAX MicroMAX-SOCWiMAX MicroMAX-SOCWeb Based ManagementWeb Based Management

Reference: 605-0000-743 MicroMAX-SOC Web-based Management

Page 20: 002. as Micromax-soc Bs

24 October 200620

Web Based ManagementWeb Based Management

• Provides a User interface tool for MicroMAX-SOC Management

• Allows viewing of configuration settings.

– BSID

– SNMP Config

– IP Address

• Permits Advanced Configuration of settings

– Software Upgrades

– Setting SS Parameters

• Allows Remote access using most Web browsers

• No “Customised” Software required to be loaded

Page 21: 002. as Micromax-soc Bs

24 October 200621

Accessing Web Browser ToolAccessing Web Browser Tool

• Start your Web browser

• In the Address bar field, type the default IP address (http://10.0.0.123) of the MicroMAX-SOC Web server

• The following main menu appears:

2323

Remember to set-up Internet Explorer options iaw the manual – 605-0000-743

Address bar

Page 22: 002. as Micromax-soc Bs

24 October 200622

View System InformationView System Information

• To access System Page and show the following– Serial number

– Product Type

– Digital Board revision

– Software Version

Click on System

Page 23: 002. as Micromax-soc Bs

24 October 200623

Minimum ConfigurationMinimum Configuration

• The following must be set before trying to connect to AS8200 Netspan Management to configure Network parameters

– IP Configuration

– SNMP Communities

• Public

• Private

– UL Frequency

– DL Frequency

– TX Power

– Base Station ID

• After completion the MicroMAX-SOC must be rebooted in order for these changes to become active

All of these settings are found in the Advanced menus

Page 24: 002. as Micromax-soc Bs

24 October 200624

IP ConfigurationIP Configuration

• The main menu allows setting the following parameters for the BS

– Name – IP Address– Subnet Mask– Default Gateway

• Use Submit button to set the parameters

10.0.0.18

Page 25: 002. as Micromax-soc Bs

24 October 200625

SNMP CommunitiesSNMP Communities

• SNMP Communities menu allows setting of:

– Community string for Netspan “read” parameter – Community string for Netspan “write” parameter

• By Default– Read Community string – “public”– Write Community string – “private”

Page 26: 002. as Micromax-soc Bs

24 October 200626

Software DownloadSoftware Download

Note: In order to Activate “new” downloaded sw then “Swap Versions” must be selected and then reset.

Page 27: 002. as Micromax-soc Bs

24 October 200627

Advanced Menu SelectionAdvanced Menu Selection

• MicroMAX-SOC WEB management includes the option of Advanced menus

• A variety of detailed menus

• Only a small number of these menus are required for standard operation

– Most options are available & configured through AS8200 Netspan

Page 28: 002. as Micromax-soc Bs

24 October 200628

Advanced Tool bar optionsAdvanced Tool bar options

Option Description

Home To return to main Menu

PROV SF Provisioned Service Flow. Assigned during device provisioning and is intended to provide an upper limit on the QoS level for a particular service. Base Station ONLY.

SS To set parameters for different Subscriber units. Applicable to Base Station & Subscriber Station. (ie. EasyST / ProST)

Link To display Link information for the different Subscriber units. Applicable to Base Station ONLY

Config To retrieve / set Base Station parameters

Forwarding To retrieve information on LAN tables and other interfaces

PKM To retrieve / set Programmable Key Module settings

Debug To set Debug states

Page 29: 002. as Micromax-soc Bs

24 October 200629

Using Advanced MenusUsing Advanced Menus

• Select the desired option from the top of the page such as:– Home

– SS

– Config

– Forwarding

• Select the desired sub-option on the left side of the page

• Show Xxxx… options are used to get information about parameters in MicroMAX-SOC

• Set Xxxx… options are used to set parameters in MicroMAX-SOC

• Press the Call button to get the information or to set the parameters

• After setting parameters – use the show Xxxx option to see them, for example:

– setMacDl sets downlink parameters of MicroMAX-SOC

– showMacDl shows downlink parameters of MicroMAX-SOC

Page 30: 002. as Micromax-soc Bs

24 October 200630

Example of an Advanced menu ScreenExample of an Advanced menu Screen

Home option

Selecting sub-options

Call button

Values of the sub optionparameters

SS option Config option

Forwarding option

Page 31: 002. as Micromax-soc Bs

24 October 200631

MAC Advanced MenusMAC Advanced Menus

Menu name What it isshowMacUl Shows uplink parameters such as the

uplink frequency channel (KHz) and the Burst Profiles

setMacUl Sets uplink parameters such as the

uplink frequency channel (KHz)

showMacDl Shows downlink parameters such as the

Downlink frequency channel (KHz), BS ID and BS Tx power (“bsEirp”)

setMacDl Sets downlink parameters such as the

Downlink frequency channel (KHz), BS ID and BS Tx power (“bsEirp”)

showMacFrame Shows the MAC frame configuration parameters:

Channel bandwidth (3.5MHz or 3,500 KHz in MicroMAX-SOC 3.5FDD first release)

cp and Frame Duration (10 msec in 1060 BSR 3.5FDD first release)

setMacFrame Sets the MAC frame configuration parameters:

Channel bandwidth, cp and Frame Duration

Note: set only to values supported by the relevant board and the relevant release

Page 32: 002. as Micromax-soc Bs

24 October 200632

PROV SF MenuPROV SF Menu

See Manual for further information

Default is False (0) – Meaning do not Show more Information

STRING = Format nn,nn,nn,nn,nn,nn

(Airspan 00A00A)Select SS MAC or CID

Page 33: 002. as Micromax-soc Bs

24 October 200633

Advanced PROV SF MenusAdvanced PROV SF Menus

Menu name What it is

showSs Shows information about subscriber stations such as:

SS id, SS MAC address, state, basic CID, primary CID, secondary CID and burst profiles

Allows to select SS with a given MAC address or with a given Connection ID (CID)

showProvSf Shows details of Provisioned Service Flows

Allows to select SF with given SF ID (SFID) or with given CID

deleteProvSf Deletes Service Flows

addProvSf Adds a provisioned SF including the packet classifiers, min rate and max rate

Page 34: 002. as Micromax-soc Bs

24 October 200634

Common Terms usedCommon Terms used

Term What it is

BP Burst Profile such as: BPSK1/2, 16QAM1/2

bsId Base Station Identified (BSID) – needs to match BSID + Mask set in EasyST / ProST / SS

CID Connection ID

Dl Downlink

ProvSf Provisioned Service Flow

RFI RF Interface

Sc Service Class

Scid Service Class ID

Sf Service Flow

Sfid Service Flow ID

Ss Subscriber Station (SS) – such as EasyST, ProST, ProST-WiFi

Ul Uplink

Page 35: 002. as Micromax-soc Bs

24 October 200635

Restarting MicroMAX-SOCRestarting MicroMAX-SOC

Select RESET

Page 36: 002. as Micromax-soc Bs

24 October 200636