01 loads
TRANSCRIPT
1
! Introduction! Fundamental of Structural Theory! Classification! Loads! Structural Design
TYPES OF STRUCTURES AND LOADS
2
Introduction
� Design of Structures
- Safety- Esthetics- Serviceability- Environment- Economy
� Structure��.. a system of connected parts used to support a load�..�
� Analysis of Structures
- Strength- Rigidity
� Idealization of Structures
- Physical Model- Mathematical Model
3
Fundamental of Structural Theory
� Idealization� Physical Model
� Members� Connections� Supports� Loads� Free-body Diagrams
� System� Member
� Mathematical Model� Equilibrium Conditions� Compatibility Conditions� Constitutive Relationship
4
Mathematical Model
� Equilibrium conditions
ΣF = 0, ΣM = 0
� Compatibility conditions
- Continuity condition- Boundary condition
� Constitutive relationship of stress and strain
εσ
=E
5
Classification of Structures
� Structural Elements
tie rod
Tie Rods
rod bar
angle channel
typical cross sections
6
simply supported beam
cantilevered beam
fixed-supported beam
overhanging beam
continuous beam
Beams
M V
web
flange
flange
8
Trusses
� Types of Structures
Cables and Arches
cables support their loads in tension arches support their loads in compression
compression
tension
10
Loads
� Dead Loads� Live Loads
� Building Loads� Bridge Loads
� Wind Loads� Snow Loads� Earthquake Loads� Hydrostatic and Soil Pressure� Other Natural Loads
11
Table 1-1 Codes
Manual for Railway Engineering, American Railway Engineering Association (AREA)
General Building CodesMinimum Design Loads for Building and other Structures, ANSI / ASCE 7-95, American Society of Civil Engineers*Basic Building Code, Building Officials and Code Administrators International (BOCA)*Standard Building Code, Southern Building Code Congress International *Uniform Building Code, International Conference of Building Officials (UBC)
Design CodesBuilding Code Requirements for Reinforced Concrete, Am. Conc. Inst. (ACI)Manual of Steel Construction, American Institute of Steel Construction (AISC)Standard Specifications for Highway Bridges, American Association of StateHighway and Transportation Officials (AASHTO)National Design Specification, American Institute of Timber Construction (ATTC)
12
1. วัสดทุั่วไป kg/m3
คอนกรีตเสริมเหล็ก 2400 คอนกรีตลวน 2320 ไมสัก 630 ไมเนื้อออน 500-1000 ไมเนื้อเข็ง 700-1200 เหล็ก 78502. วัสดมุุงหลังคา kg/m2
กระเบื้องลอนคู 14 กระเบื้องลูกฟกูลอนเล็ก 12 กระเบื้องลูกฟกูลอนใหญ 50 กระเบื้องราง 12 กระเบื้องซีแพคโมเนีย 50 สังกะสี 53. โครงหลังคา 10-30
Table 1-2 น้ําหนักบรรทุกคงที่
4. แปไม 55. พื้นไม 1� รวมตง 30-506. ฝา ฝา กําแพง kg/m2
คราวไม 11/2� X 3� @ 0.40 15 คราวไม 11/2� X 3� @ 0.60 10 กระเบื้องแผนเรียบหนา 4 mm 7 กระเบื้องแผนเรียบหนา 8 mm 14 แผนเอสเบสโตลักส 4 ไมอดัหนา 4 mm 4 ฝาไม 1/2� รวมคราว 20 อิฐมอญหนา 10 cm 180 อฐิมอญเต็มแผนฉาบปูน 360 คอนกรีตบล็อคหนา 10 cm 100-150 คอนกรีตบล็อคหนา 15 cm 170-180 คอนกรีตบล็อคหนา 20 cm 220-240
ชนิดของวัสดุ น้ําหนักบรรทุกคงที่ ชนิดของวัสดุ น้ําหนักบรรทุกคงที่
13
Table 1-3 น้ําหนักบรรทุกจร
ประเภทสวนตางๆ ของอาคาร หนวยน้ําหนักบรรทุกจร (kg/m2)
1. หลังคา 302. กันสาดหรือหลังคาคอนกรีต 1003. ที่พักอาศัย รร. อนุบาล หองน้ํา หองสวม 1504. หองแถว ตึกแถวที่ใชพัักอาศัย อาคารชุดหอพกั โรงแรม และหองคนไขพเิศษของโรงพยาบาล 2005. สํานักงาน ธนาคาร 2506. (ก) อาคารพาณิชย สวนของหองแถว ตึกแถวที่ใชเพือ่อาคาร พาณิชย มหาวิทยาลัย วิทยาลัย โรงเรียน และโรงพยาบาล 300 (ข) หองโถง บันได ชองทางเดนิของอาคารชุด หอพัก โรงแรม สํานักงานธนาคาร 3007. (ก) ตลาด อาคารสรรพสินคา หอประชุม โรงมหรสพ ภัตตาคาร หองประชุม หองอานหนังสือในหองสมุด หรือหอสมุด ที่จอดรถ หรือเก็บรถยนตนั่ง หรือรถจักรยานยนต 400 (ข) หองโถง บันได ชองทางเดินของตลาด อาคารสรรพสินคา หองประชุม หอประชุม โรงมหรสพ ภัตตาคาร หองสมุดและหอสมุด 500
14
Table 1-3 น้ําหนักบรรทุกจร (ตอ)
ประเภทสวนตางๆ ของอาคาร หนวยน้ําหนักบรรทุกจร (kg/m2)
8. (ก) คลังสินคา โรงกีฬา พิพธิภัณฑ อัฒจันทร โรงงานอุตสาหกรรม โรงพมิพ หองเก็บเอกสาร และพสัดุ 500 (ข) หองโถง บันได ชองทางเดนิของตลาด อาคารสรรพสินคา หองประชุม หอประชุม โรงมหรสพ ภัตตาคาร หองสมุดและหอสมุด 5009. หองเก็บหนังสือของหองสมุดหรือหอสมุด 60010. ที่จอดรถหรือเก็บรถยนตบรรทุกเปลา 800
15
� ในการคํานวณน้ําหนักที่ถายลงเสา คาน หรือโครงที่รับเสาและฐานราก ใหใชน้ําหนักของอาคารเตม็อัตรา สวนหนวยน้ําหนักบรรทุกจรใหใชตามที่กําหนดไวในตารางที่ 1-3 โดยใหลดสัดสวนไดตามชั้นของอาคาร ดังตอไปนี้
การรับน้ําหนักของพื้น อัตราการลดหนวยน้ําหนักบรรทุกจร บนพื้นแตละชัน้เปนรอยละ
(1) หลังคาหรือดาดฟา 0(2) ชั้นที่หนึ่งถัดจากหลงัคาหรือดาดฟา 0(3) ชั้นที่สองถดัจากหลังคาหรือดาดฟา 0(4) ชั้นที่สามถัดจากหลังคาหรือดาดฟา 10(5) ชั้นที่สี่ถัดจากหลังคาหรือดาดฟา 20(6) ชั้นที่หาถัดจากหลังคาหรือดาดฟา 30(7) ชั้นที่หกถดัจากหลังคาหรือดาดฟา 40(8) ชั้นที่เจ็ดถัดจากหลังคาหรือดาดฟาและชัน้ตอลงไป 50
สําหรับโรงมหรสพ หองประชมุ หอประชมุ หองสมุด หอสมุด พิพิธภณัฑ อัฒจันทร คลังสินคา โรงงานอุต-สาหกรรม อาคารจอดหรือเก็บรถยนต หรอืรถจักรยานยนต ใหคิดหนวยน้ําหนักบรรทุกจรเต็มอัตราทุกชั้น
16
Where,
L = reduced design live load per square foot or square meter of area supported by the member, > 0.5 Lo for 1 floor, > 0.4 Lo for 2 floors or moreLo = unreduced design live load per square foot or square meter of area supported by the member (see Table 1-4)AI = influence area in square feet (> 400) or (>37) square meters, equal to four times the tributary or effective load-carrying floor area for a column, and two times the tributary or effective load-carrying floor area for a beam*
(FPS units)L = ( 0.25 + 15
AI
(
(SI units)L = ( 0.25 + 4.57
AI
(
The reduced load L� >.50 Lo , for floor (2-story) � >.40 Lo , for floor (>2-story) � =1.00 Lofor roof, public hall, parking garage
Lo
Lo
17
Live LoadOccupancy or Use psf kN/m2
Assembly areas and theatersFixed seats 60 2.87Movable seats 100 4.79Dance halls and ballrooms 100 4.79Garages (passenger cars only) 50 2.40
Office buildingsLobbies 100 4.79Offices 50 2.40
Storage warehouseLight 125 6.00Heavy 250 11.97
ResidentialDwellings (one- and two-family) 40 1.92Hotels and multifamily houses
Private rooms 40 1.92Public rooms 100 4.79
SchoolsClassrooms 40 1.92Corridors above first floor 80 3.83
Table 1-4 Minimum Live Loads*
18
Example 1-1
The floor beam in the figure below is used to support the 2 m width of alightweight plain concrete slab having a thickness of 10 cm. The slab serves as aportion of the ceiling for the floor below, and therefore its bottom is coated withplaster (25 kg/m2). Furthermore, an 2.5 m height, 30 cm thick masonry wall isdirectly over the top flange of the beam. Determine the loading on the beammeasured per foot of length of the beam.
30 cm.
2.5 m.
1 m. 1 m.10 cm.
plaster
19
SOLUTION
1. วัสดทุั่วไป kg/m3
คอนกรีตเสริมเหล็ก 2400 คอนกรีตลวน 2320 ไมสัก 630 ไมเนื้อออน 500-1000 ไมเนื้อเข็ง 700-1200 เหล็ก 78502. วัสดมุุงหลังคา kg/m2
กระเบื้องลอนคู 14 กระเบื้องลูกฟกูลอนเล็ก 12 กระเบื้องลูกฟกูลอนใหญ 50 กระเบื้องราง 12 กระเบื้องซีแพคโมเนีย 50 สังกะสี 53. โครงหลังคา 10-30
Table 1-2 น้ําหนักบรรทุกคงที่
4. แปไม 55. พื้นไม 1� รวมตง 30-506. ฝา ฝา กําแพง kg/m2
คราวไม 11/2� X 3� @ 0.40 15 คราวไม 11/2� X 3� @ 0.60 10 กระเบื้องแผนเรียบหนา 4 mm 7 กระเบื้องแผนเรียบหนา 8 mm 14 แผนเอสเบสโตลักส 4 ไมอดัหนา 4 mm 4 ฝาไม 1/2� รวมคราว 20 อิฐมอญเต็มแผนฉาบปูน 360 อิฐบล็อคหนา 10 cm 100 คอนกรีตบล็อคหนา 10 cm 100-150 คอนกรีตบล็อคหนา 15 cm 170-180 คอนกรีตบล็อคหนา 20 cm 220-240
ชนิดของวัสดุ น้ําหนักบรรทุกคงที่ ชนิดของวัสดุ น้ําหนักบรรทุกคงที่
20
30 cm.
2.5 m.
1 m. 1 m.10 cm.
14 kN/m (1430 kg/m)
Concrete slab: )2400( 3mkg 480)1.0)(2( =mm kg/m
Plaster ceiling: 50)2)(25( 2 =mmkg kN/m
)360( 2mkg
Masonry wall: 900)5.2( =m kg/m
คอนกรีตเสริมเหล็ก 2400 kg/m3
อิฐมอญเต็มแผนฉาบปูน 360 kg/m2
Total load 1430= kg/m
21
Example 1-2a
A two-story office building has interior columns that are spaced 7 m apart in twoperpendicular directions. If the (flat) roof loading is 100 kg/m2 determine thereduced live load supported by the spread-footing foundation. Assume the groundfloor is a slab on grade.
At 7 m
7 m
7 m7 m
22
At
SOLUTION: ANSI-based US Code
7 m
7 m
7 m7 m
FR = (100 kg/m2)(49 m2) = 4.90 T
For the second floor, the live load is taken from table 1-4:Lo = 250 kg/m2 .
Since AI = 4At = 4(49 m2) = 196 m2 > 37.2 m2 , the live load can be reduced. Thus,
2/144250)575.0(250))49(4
57.425.0()457.425.0( mkgLA
L oT
==+=+=
The load reduction = (0.575) L0 > ( 0.50) L0 O.K. Therefore
FF = (144 kg/m2)(49 m2) = 7.044 T
The roof loading is 100 kg/m2
At = (7 m)(7 m) = 49 m2
23
At 7 m
7 m
7 m7 m
For the ground floor, the live load is taken from table 1-4:Lo = 250 kg/m2 . No live load reduction is allowed.
FG = (250 kg/m2)(49 m2) = 12.25 T
The total live load supported by the foundation is thus
F = FR + FF + FG = 4.90 + 7.044 + 12.25 = 24.19 T
24
At
SOLUTION: Thai Code
7 m
7 m
7 m7 m
FR = (100 kg/m2)(49 m2) = 4.90 T
For the second and ground floor, the live load istaken from table 1-4:Lo = 250 kg/m2 .
FF = (250 kg/m2)(49 m2) = 12.25 T
The total live load supported by thefooting is thus
F = FR + FF = 4.90 + 12.25 + 12.25 = 29.4 T
roof loading is 100 kg/m2
At = (7 m)(7 m) = 49 m2
25
Example 1-2b
A eleven-story office building has interior columns that are spaced 7 m apart intwo perpendicular directions. If the (flat) roof loading is 100 kg/m2 and floorloading is 250 kg/m2 determine the reduced live load supported by a typicalinterior footing using the US code and Thai code.
At 7 m
7 m
7 m7 m
10987654321
ground
roof deck
26
At
SOLUTION
7 m
7 m
7 m7 m
For the second floor, the live load is taken from table 1-4:Lo = 250 kg/m2 .
Since 4At = 4(49 m2) = 196 m2 > 37.2 m2 , the live load can be reduced. Thus,
2/144)250(575.0
250)19657.425.0(
)457.425.0(
mkg
LA
L ot
==
+=
+=
The load reduction here is (0.575)L0 > (0.40)L0 O.K. Therefore use 0.575 for all.
At = (7 m)(7 m) = 49 m2
For Thai code: see table 1-3b.
For the US code based on ANSI:
10987654321
ground
roof deck
27
Roof deck
ground
10
9
8
7
6
5
4
3
2
1
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(0.575)(250)(49)
(1.000)(100)(49)
(1.000)(250)(49)
(1.000)(250)(49)
(1.000)(250)(49)
(0.900)(250)(49)
(0.800)(250)(49)
(0.700)(250)(49)
(0.600)(250)(49)
(0.500)(250)(49)
(0.500)(250)(49)
(0.500)(250)(49)
(0.500)(250)(49)
(1.000)(100)(49)
(1.000)(250)(49)
FloorLive load (kg) Accumulated load (kg)
American Code Thai Code
Live load (kg) Accumulated load (kg)
4 900
11 940
18 990
26 030
33 080
40 120
47 160
54 210
61 250
68 290
75 340
87 590
4 900
17 150
29 400
40 420
50 220
58 800
66 150
72 280
78 400
84 500
90 650
102 900
28
Example 1-2c
A eleven-story office building has interior columns that are spaced 7 m apart intwo perpendicular directions. If the (flat) 15 cm-thick roof liveload is 100 kg/m2
and 20 cm-thick floor live loading is 300 kg/m2 determine the reduced live loadsupported by a typical interior footing using the US code and Thai code.
At 7.5 m
7.5 m
7.5 m7.5 m
10987654321
ground
roof deck
29
At
SOLUTION
7.5 m
7.5 m
7.5 m7.5 m
For the second floor, the live load is taken from table 1-4:Lo = 250 kg/m2 .
Since 4At = 4(56.25 m2) = 225 m2 > 37.2 m2 , the live load can be reduced. Thus,
2/4.166)250(555.0
300)22557.425.0(
)457.425.0(
mkg
LA
L ot
==
+=
+=
The load reduction here is (0.555)L0 > (0.40)L0 O.K.
At = (7.5 m)(7.5 m) = 56.25 m2
For Thai code: see table 1-3b.
For the US code based on ANSI:
10987654321
ground
roof deck
30
Roof deck
ground
10
9
8
7
6
5
4
3
2
1
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(480)(56)
(1.000)(360)(56)
(1.000)(480)(56)
FloorDead load (kg) Accumulated load (kg)
Thai & US Codes
20 250
47 250
74 250
101 200
128 200
155 200
182 200
209 200
236 200
263 250
290 250
317 200
31
Roof deck
ground
10
9
8
7
6
5
4
3
2
1
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(0.555)(300)(56)
(1.000)(100)(56)
(1.000)(300)(56)
(1.000)(300)(56)
(1.000)(300)(56)
(0.900)(300)(56)
(0.800)(300)(56)
(0.700)(300)(56)
(0.600)(300)(56)
(0.500)(300)(56)
(0.500)(300)(56)
(0.500)(300)(56)
(0.500)(300)(56)
(1.000)(100)(56)
(1.000)(300)(56)
FloorLive load (kg) Accumulated load (kg)
US Code Thai Code
Live load (kg) Accumulated load (kg)
5 625
14 990
24 360
33 720
43 090
52 450
61 820
71 180
80 550
89 920
99 280
116 100
5 625
22 500
39 380
54 560
68 080
79 880
90 000
98 440
106 880
115 310
123 800
140 600
32
I = <L + 38.1
15.240.3
For highway c the AASHTO Specification gives the expression for the impact factor as
In which L is the length in meter of the portion of the span loaded to cause the maximum stress in the member under consideration.
2.9 T 9.1 T 4.6 T 8.2 T 8.2 T4.2 m 1.2 m4.2 m
Bridge Loads
12 Ton Truck 21 Ton Truck
33
Wind Loads
θทิศทางลม
ดานปะทะลม(windward)
ดานทายลม(leeward)
Wind Pressure for Building� External Pressure� Internal Pressure
35
p = q G C
Where,
q = basic pressure at the height of 10 m = 0.613 KzKztV 2I (N/m2, m/s)p = wind pressureG = gust factor (0.85, typical)C = shape factor
External Pressure: Formulation
36
qhGCp
(p = qhGCp)side wall
qhGCp
qzGCp
wind
B
L
ridge
plan
qhGCp
qhGCpqhGCp
qzGCp
q = 0. 613 KzKztV 2I q, N/m2
V , m/s
External Pressure on Main Wind-Resisting System
elevation
θ
z
h
4.6 m
37
wind
B
L
ridge
plan
elevation
θ
z
h
Cp, typical
qz = 0.613 KzKztV 2I (N/m2)
pz = qz G Cp
Cp = 0.5Cp = 0.8
CpCp
Cp = 0.8 Cp = 0.5
Cp = 0.7
Cp = 0.7
G = 0.85, typicalKzt=1, flat area
38
Internal Pressure: Enclosed Building*
0.18qh 0.18qh
Internal Pressure: Partially Open Building*
0.55qh 0.55qh
* Reference: ASCE 7-98
39
Total WindPressure on theMain Wind-ForceResisting System:Enclosed Building qzGCp
qhGCp
qhGCp
qhGCp
+
0.18qh
+
0.18qh
qhGCp
=
pz
ph
ph
ph
ph
A pz
ph
ph
ph
ph
B
=
40
qz = 0.613 KzKztV 2I (N/m2)
Where,
V = the velocity in m/s of a 3-second gust of wind measured at 10 m above the ground during a 50-year recurrence period. Values are obtained from a wind map.I = the importance factor that depends upon the nature of the building occupancy (see Table 1-6)Kz = the velocity pressure exposure coefficient, which is a function of height and depends upon the ground terrain (use equation or see graph 1-1).Kzt = a factor that accounts for wind speed increases due to hills and escarpments. For flat ground Kzt = 1q = qz for windward wall, = qh for others
Detail:p = q GCp - qh(GCpi)
GCp = ±0.18, enclosed building*
GCp = ±0.55, partially enclosed building*
GCp = ±0, open building*
41
Kz =
α/2)(01.2gzz
gzzm ≤≤6.4for
α/2)6.4(01.2gz mz 6.4<for
Kz can be calculated using the formula:
42
Exposure BUrban and
suburban areas
Exposure ALarge city centers
Exposure COpen terrain
Exposure DEdge of large
bodies of water
Table 1-5 Exposure Categories for Buildings for Wind Loads
Constants
Exposure Category zg, m αααα G
Flat, unobstructed coastal areas D 213 11.5 0.85
Large city centers with at least 50% of the buildings having heights in excess of 70 ft ( 21m) A 457 5.0 0.85
Urban and suburban areas with closely spaced obstructions of the size of single family houses or larger B 366 7.0 0.85
Open terrain with scattered obstructions of heights generally less than 30 ft (9 m) C 274 9.5 0.85
47
Heg
iht z
(m)
Kz0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
30
20
10
4.6
1.6
Expo
sure
A
Expo
sure
B
Expo
sure
C
Expo
sure
D
Graph 1-1
OR Kz by graph :
0.85
48
All buildings other than those listed in Categories I, III and IV II 1.00Buildings representing a substantial hazard to human life in the case of failure, such as: those where more than 300 people congregate in one area; schools and day-care facilities with capacity greater than 250; colleges with capacity greater than 500; hospitals without emergency treatment or surgery facilities but with patient capacity greater than 50; jails, power stations and utilities not essential in an emergency; and buildings containing toxic and explosive materials III 1.15Essential facilities, including hospitals, fire and police stations, national defense facilities and shelters, communication centers, power stations, and utilities required in an emergency IV 1.15
Building representing low hazard to human life in the case of failure, such as agricultural and minor storage facilities I 0.87
Table 1-6 Classification of Buildings for Environmental Loads
Importance Factor, I
Occupancy or use Category Wind loads
49
Surface L/B Cp Use with
Table 1-7 Wall pressure coefficients, Cp
windward wall All values 0.8 qz
>
Leeward wall 0-1 -0.52 -0.3 qh 4 -0.2
Side walls All values -0.7 qh
51
Wind Cp direction h/L
Horiz distance fromwindward edge0 to h/2 -0.9h/2 to h -0.9h to 2h -0.5>2h -0.3
0.5≤
1.0≥ 0 to h/2 -1.3**>h/2 -0.7
Normalto
ridgefor
θ < 10o
andparallel
to ridgefor all θ
*Value is provided for interpolationpurposes**Value can be reduce linearly witharea over which it is applicablefollows: Area Reduction (ft2) factor 100 (9.29 sq m) 1.0 250 (23.23 sq m) 0.9 1000 (92.9 sq m) 0.8
*** For roof slopes greater than 80o,use Cp = 0.8.
≤
≥
Table 1-8A Windward Roof Pressure Coefficients, Cp , θ < 10o
52Roof slope,θ degrees0 10 20 30 40 50 60 70
-1.3
0.5
0.3
0.1
-0.1
-0.3
-0.5
-0.7
-0.9
-1.1
0
Win
dwar
d R
oof P
ress
ure
Coe
ffic
ient
s, C
p
Negati
ve pr
essu
re
Posit
ive pr
essu
re<<<< 0.25h/L
>>>> 10o , θθθθ
Graph 1-2
53Roof slope,θ degrees0 10 20 30 40 50 60 70
-1.3
0.5
0.3
0.1
-0.1
-0.3
-0.5
-0.7
-0.9
-1.1
0
Win
dwar
d R
oof P
ress
ure
Coe
ffic
ient
s, C
pPositiv
e pressure
Negative pres
sure
h/L = 0.5
>>>> 10o , θθθθ Graph 1-3
54Roof slope,θ degrees0 10 20 30 40 50 60 70
-1.3
0.5
0.3
0.1
-0.1
-0.3
-0.5
-0.7
-0.9
-1.1
0
Win
dwar
d R
oof P
ress
ure
Coe
ffic
ient
s, C
p
>>>> 10o , θθθθ
>>>> 1.0h/L
Positive pressu
re
Nega
tive p
ress
ure
Graph 1-4
55
≤
≥
Normalto
ridgefor
θ 10o≥ ≥
Table 1-9 Leeward Roof Pressure Coefficients, Cp
Leeward angle, θθθθ (degrees)Wind direction h/L 10 15 20
0.25 -0.3 -0.5 -0.6
0.5 -0.5 -0.5 -0.6
1.0 -0.7 -0.6 -0.6
56
Example 1-3a
The building shown is mostly closed (internal pressure is considered) is used foran industrial purpose. The building is located in the industrial park situated in theflat open terrain in Pak Thongchai, Nakhon Ratchasima. Determine the wind loadacting on the walls, sides and roofs following the guidelines given byANSI/ASCE 7-95, and draw diagrams of the possible loading calculated.
wind30 m 15 m
6.5 m
140 km/h
15o
58
6.5 m
7.5 m 7.5 m
15o
h = 6.5 + (7.5tan15o )/2 = 7.5 m
qz = 0.613 KzKztV 2I (N/m2)
� Find qz and qh
)6060
1)(10140(3
sh
hmV
××
= = 38.89 m/s, I = 1.0 and Kzt = 1 for flat terrain. Therefore,
qz = 0.613 Kz(1)(38.89)2(1) = 927Kz ----------(1)
59
Heg
iht z
(m)
Kz0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
30
20
10
4.6
1.6
Ex
p. C
Graph 1-1
qz = 927 Kz GKz, N/m2 (G=.85)z (m) Kz
0-46.5h = 7.5
788 670844 717872 741
0.850.910.94
60
� Find Cp and G
- Windward wall, leeward wall and side walls find from table 1-7.Leeward roof find from table 1-9 and windward roof find from graph 1-3.See in the reference in the back.
Cp = 0.5Cp = 0.8
Cp = 0.5
15o
Cp = 0.7
L/B = 15/30 = 0.5
B
L
ridge
plan
Cp = 0.8 Cp = 0.5
Cp = 0.7
Cp = 0.7
61
� Institute all values for the main frame
(717)(0.8) = 574 N/m2
(872)(0.85)0.5) = 370 N/m2
(872)(0.85)(0.85)(0.5) = 370 N/m2(741)(0.7) = 518 N/m2
+
0.18qh
0.18qh =0.18(872) = 157 N/m2 +
0.18qh
(670)(0.8) = 536 N/m2
z=7.5m: qhG= (872)(0.85)=741 N/m2
z= 4 m: qhG= (788)(0.85)=670 N/m2
z=6.5m: qhG= (844)(0.85)=717 N/m2
=
731 N/m2
693 N/m2
214 N/m2
214 N/m2362 N/m2
A 528 N/m2
527 N/m2675 N/m2
379 N/m2
417 N/m2
=
B
62
qhGCp
362 N/m2
214 N/m2
qzGCp
B
L
ridge
plan
qhGCp
675 N/m2
528 N/m2
qzGCp
B
L
ridge
plan
731 N/m2
693 N/m2
214 N/m2
214 N/m2362 N/m2
A 528 N/m2
527 N/m2675 N/m2
379 N/m2
417 N/m2
B
Conclusion
63
Example 1-3b
The building shown in the figure is used for industrial purpose and is locatedoutside of Nakhon Ratchasima, Thailand on flat terrain. When the wind isdirected as shown, determine the design wind pressure acting on the roof andsides of the building using the ANSI / ASCE 7-95 Specifications. Use G = 0.85.
wind30 m 15 m
6 m
150 km/h
9 m
64
wind30 m 15 m
6 m
150 km/h
9 m
qz = 0.613 KzKztV 2I (N/m2)
The basic wind speed is V = 150 km/h = 41.67 m/s , and since the building is used for industrial purposes, the importance factor is I = 1.0. Also, for flat terrain, Kzt = 1. Therefore,
qz = 0.613 Kz(1)(41.67)2(1.0) = 1064 Kz N/m2
θ = tan-1(3/7.5) = 22o, the mean height of the roof is h = 6 + 3/2 = 7.5
θ h
65
Hei
ght z
(m)
Kz0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
30
20
10
1.6Ex
posu
re C
Graph 1-1
h = 7.5
Kh = 0.95
Expo
sure
A
Expo
sure
B
Expo
sure
D
66
From graph Kz = 0.95
qh = 1064 Kh = 1064(0.95) = 1011N/m2
qhG = 1011(0.85) = 859.5 N/m2
qhGCp qhGCp
qhGCpqzGCp 0.85qzCp859.5 Cp
859.5 Cp 859.5 Cp
67
Hei
ght z
(m)
Kz0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
30
20
10
4.6
1.6Ex
posu
re C
Graph 1-1
904.8958.0
qz = 1064 Kz (N/m2)
0.850.90
z (m) Kz
0-46
68
Surface L/B Cp Use with
Table 1-7 Wall pressure coefficients, Cp
windward wall All values 0.8 qz
>
Leeward wall 0-1 -0.52 -0.3 qh 4 -0.2
Side walls All values -0.7 qh
L/B = 15/30 = 0.5
Cp = 0.5Cp = 0.8
CpCp
69
CpCp Cp = 0.6
≤
≥
Normalto
ridgefor
θ 10o≥ ≥
Table 1-9 Roof Pressure Coefficients, Cp , for Use with qh
Leeward angle, θθθθ (degrees)Wind direction h/L 10 15 20
0.25 -0.3 -0.5 -0.6
0.5 -0.5 -0.5 -0.6
1.0 -0.7 -0.6 -0.6
h/L = 7.5/15 = 0.5
Cp = 0.5Cp = 0.8
70Roof slope,θ degrees0 10 20 30 40 50 60 70
-1.3
0.5
0.3
0.1
-0.1
-0.3
-0.5
-0.7
-0.9
-1.1
0
Win
dwar
d R
oof P
ress
ure
Coe
ffic
ient
s, C
p
h/L = 0.5
Positive pressure
Negative pres
sure
>>>> 10o , θθθθ Graph 1-3
Cp = 0.5Cp = 0.8
Cp = 0.622o
Cp = 0.08
Cp = 0.36
71
904.8958.0
qz = 1064.41 Kz (N/m2)
0.850.90
z (m) Kz
0-46
859.5
859.5 859.5
0.85
q z Cp = 0.5Cp = 0.8
Cp = 0.622o
Cp = 0.08
Cp = 0.36
×429.8 N
/m2
515.7 N/m2
68.76 N/m2
309.4 N/m2
615.2 N/m2
651.4 N/m2
72
429.8 N/m
2
515.7 N/m2
68.76 N/m2
309.4 N/m2
615.2 N/m2
651.4 N/m2
+
0.18qh
+
0.18qh
0.18qh = 182.0 N/m2
=
250.8 N/m2
247.8 N/m
2
333.7 N/m2
A
127.4 N/m2
797.2 N/m2
833.4 N/m2
611.8 N/m
2
697.7 N/m2113.2 N/m2
B
=491.4 N/m2
433.4 N/m2
469.4 N/m2
73
251 N/m2
248 N/m
2
334 N/m2
A
127 N/m2
797 N/m2
833 N/m2
612 N/m
2698 N/m2
113 N/m2
B
491 N/m2
433 N/m2
469 N/m2
Conclusion
419 N/m2
419 N/m2
248 N/m2
qzGCp
B
L
ridge
plan
783 N/m2
783 N/m2
412 N/m2
qzGCp
B
L
ridge
plan
74
Design Wind Pressure for Signs.
ffz AGCqF =
HereG = the wind-gust coefficient factor defined previously, 0.85 (typical)Cf = a force coefficient which depends upon the ratio of the large dimension M of the sign to the small dimension N. Values are listed in table belowAf = the area of the face of the sign
Force Coefficients for Above-Ground Solid Signs, Cf.
M/N Cf
<6 1.210 1.320 1.540 1.7560 1.85
L
B
75
Earthquake Loads
Deformedconfiguration
Initial (undeformed)configuration
V = CsW
Where, V = total lateral force or base shear, W = dead load of the building,Cs = seismic response coefficient
Cs = 1.2Cv
RT2/3<
R
2.5Ca
Where, Cv and Ca are the seismic coefficients based on the soil profile, and on theeffective peak velocity-related acceleration (Av) and the effective peak acceleration (Aa) respectively; R denotes the response modification factor; and T represents the fundamental period of vibration of the structure.
Ground motion
76
Hydrostatic and Soil Pressure
hp = γ h
p = γ h
Where, γ = unit weight of the liquid.
Other Natural Loads
Several other types of live loads may also have to be considered in design ofa structure, depending on its location or use. These include the effect of blast,temperature changes, and differential settlement of the foundation.
77
Structural Design
Reinforced Concrete Structures
1.) 1.4D + 1.7L2.) 0.75 [1.4D + 1.7L + 1.7W]3.) 0.9D + 1.3W 4.) 1.4D + 1.7L + 1.7(soil pressure)5.) 0.75 [1.4D + 1.7(temperature load) + 1.7L] 6.) 1.4(D + temperature load)
Steel Structures 1.) 1.4D2.) 1.2D + 1.6L + 0.5(roof live load)3.) 1.2D + 0.5L (or 0.8W) + 1.6(roof live load) 4.) 1.2D + 0.5L + 0.5(roof live load) + 1.3W5.) 1.2D + 0.5L + 1.5E6.) 0.9D -1.3W (or 1.5E)
Allowable Stress Design (ASD)
1.) D + L + [roof live load]2.) D + L + [W or E]
Where, D = Dead load, L = Live load , W = Wind load , E = Earthquake load
78
Noteกฎกระทรวง ฉบับที่ 6 (พ.ศ. 2527)
ออกตามความในพระราชบัญญัติควบคุมอาคาร พ.ศ. 2522� ในการคํานวณสวนของอาคารคอนกรีตเสริมเหล็กตามทฤษฎีกําลังประลัย ใหใชน้ําหนักบรรทุกประลัยดัง ตอไปนี้
(1) สําหรับสวนของอาคารที่ไมคิดแรงลม ใหใชน้ําหนักบรรทุกประลัย ดังนี้1.7D + 2.0L
(2) สําหรับสวนของอาคารที่คิดแรงลมดวย ใหใชน้ําหนักบรรทุกประลัย ดังนี้0.75(1.7D + 2.0L + 2.0W) หรือ 0.9D + 1.3W
โดยใหใชคาน้ําหนักบรรทุกประลัยที่มากกวา แตทั้งนี้ตองไมตํากวาค่ําน้ําหนักบรรทุกประลัยใน(1) ดวย
79
� ในการคํานวณน้ําหนักที่ถายลงเสา คาน หรือโครงที่รับเสาและฐานราก ใหใชน้ําหนักของอาคารเตม็อัตรา สวนหนวยน้ําหนักบรรทุกจรใหใชตามที่กําหนดไวในตารางที่ 1-3 โดยใหลดสัดสวนไดตามชั้นของอาคาร ดังตอไปนี้
การรับน้ําหนักของพื้น อัตราการลดหนวยน้ําหนักบรรทุกจร บนพื้นแตละชัน้เปนรอยละ
(1) หลังคาหรือดาดฟา 0(2) ชั้นที่หนึ่งถัดจากหลงัคาหรือดาดฟา 0(3) ชั้นที่สองถดัจากหลังคาหรือดาดฟา 0(4) ชั้นที่สามถัดจากหลังคาหรือดาดฟา 10(5) ชั้นที่สี่ถัดจากหลังคาหรือดาดฟา 20(6) ชั้นที่หาถัดจากหลังคาหรือดาดฟา 30(7) ชั้นที่หกถดัจากหลังคาหรือดาดฟา 40(8) ชั้นที่เจ็ดถัดจากหลังคาหรือดาดฟาและชัน้ตอลงไป 50
สําหรับโรงมหรสพ หองประชมุ หอประชมุ หองสมุด หอสมุด พิพิธภณัฑ อัฒจันทร คลังสินคา โรงงานอุต-สาหกรรม อาคารจอดหรือเก็บรถยนต หรอืรถจักรยานยนต ใหคิดหนวยน้ําหนักบรรทุกจรเต็มอัตราทุกชั้น