Technical Specifications - XAS 375 JD6
Technical Specifications - XAS 375 JD6 (2)
Technical Specifications - XAS 375 JD6 (3)
Flow summary XAS 375 JD6
6
AIR SYSTEM INLET VALVE
Spring loaded in the ready position
Control Air closes the inlet
Also serves as check valve
No-Load Condition Load Condition
Unload Condition Blow- Down Condition
9
REGULATING VALVE
Spring loaded
Adjusting receiver pressureby changing spring tension
• to pressure gauge and loading valve
• to speed regulator• to unloading valve
Regulating pressure:
Receiver pressure
The air receiver pressure can be set to another value by adjusting the spring tension of the regulating valve. This is done by turning the handle on top the valve. Increasing the spring tension, by turning in, will increase the regulating pressure and consequently the pressure inside the vessel. Turning out will decrease the pressure.
In order to regulate the pressure inside the reciever tank of our compressor, the air intake and the engine speed have to be controlled. This is done pneumatically. For that reason, we need regulating pressure. The regulating valve reduces the pressure inside the tank, thus providing the regulating pressure. This regulating pressure is then supplied to the unloader valve and the speed regulator or RPS.
10
Maintains a minimum pressure
of 58 PSI for oil flow
Also contains the final check
valve
AIR SYSTEM MINIMUM PRESSURE VALVE
Control Panel
12
XC 2002 Controller
13
XC2002 Controller Overview
14
XC 2002 Control Module
15
XC 2002 - Menus
On newer units Parameters are under Extra Views.
*Password is 2003*
XC 2002 Controller – 1.200 Program
XC 2002 Controller – 1.200 Program
Service Timer 1 = 500hrs
Service Timer 2 = 1000hrs
“On” lets you connect to engine with machine not running
Automatically unloads unit “unit will not reload”
Automatically loads “with use of in line micro switch”
XC 2002 Controller – 1.200 Program
XC 2002 Controller – 1.200 Program
XC 2002 Controller – 1.200 Program
XC 2002 Controller – 1.200 Program – Unit Type 2
Event Logging
J1939 Canbus Engine Communication
XC2002 Service Timer Reset
24
Scroll through the controller menu to “Parameters” (on some units “Parameters” may be a submenu under “Extra Views”)
Press Enter to select Parameters
Scroll to ST1 Reset or ST2 Reset as needed (ST1 = 500 hours, ST2 = 1000 hours)
Press Enter to select to reset the appropriate timer
Center option will highlight; scroll to highlight “Yes” and press Enter
Change Password to 2003 and press Enter
Service timer is reset
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Engine Fault Code List
Displaying of J1939 DM1 Alarms
Wiring Schematic – XAS 375 JD6
Canbus terminator resistor p/n 1310030622
36
Legend
37
John Deere – Tier III – RPS in place of Pneumatic Speed Regulator
Regulating Pressure Sensor
“Speed Sensor”
38
Preheat Relay K1 Controlled by JDEC
Starter RelayPreheat Relay
39
Preventive Maintenance Filter Kits – XAS 375 JD6
Spare Parts Recommendation
41
Contact Numbers
•Main Number Atlas Copco Technical Support 1-800-732-6762 Option 3
•Clayton Jones - Hurricane Boosters/Compressors - Supervisor1-216-643-6802 direct & 1-317-681-4602 mobile
•Andrew Stevenson – Compressors: Low Pressure1-720-479-2486 direct & 1-404-751-6717 mobile
•Will Hudson – Generators/Compressors 1-800-732-6762 Ext. 12920 & 1-832-454-8123 mobile
•Andrew Calendar – Compressors: High Pressure1-720-479-2487 direct & 1-404-242-6203 mobile
•Jon Monaco - Hydraulic Att./Handheld Tools 1-800-732-6762 Ext. 12929 & 1-216-816-5008 mobile
•Brandon Dyer – Compressors: Low Pressure/Hydraulic Att.1-216-643-6807 direct & 1-216-219-2290 mobile
•Scott Ellinger – Compressors1-720-479-2476 direct & 1-720-375-1795 mobile
Committed tosustainable productivity.