±7,500 kVA ELECTRICAL
±7,500 kVA GENERATORS
±4,375 kVA UPS
1360 KIFER ROADSUNNYVALE, CA | ±56,773 SF AVAVILABE FOR LEASE
DATA CENTER | LAB | MANUFACTURING
SPACE ±56,773 SFPOWER ±7,500 kVA electrical service, ±7,500 kVA back up generators and ±4,375 kVA UPS
COOLING ±1,836 tons air-cooled chillers with ±880 tons DATA CENTER CRAC units
CONNECTIVITY Fiber rich area: Adjacent to Level 3 “Gateway” and CenturyLink with additionalaccess to AT&T, Comcast and Intergra
±4,375 kVA UPS±24” Raised Floor, ±22’ Clear Height ±7,500 kVA Electrical Capacity ±7,500 kVA Standby Diesel Generators
1360 KIFER ROADSUNNYVALE, CA | ±56,773 SF AVAVILABE FOR LEASE
DATA CENTER | LAB | MANUFACTURING
BUILDING• 1360 Kifer: Approximately ±56,773 square feet with its own primary electrical
and mechanical systems
CLEAR HIGHT• ±22’ Clear height from the slab• ±24” Raised Floor
UTILITY POWER• PG&E Services this site with a primary ±21 Kilo-volt service (KV)• Electrical power for the data center is provided by PG&E via two ±12.47KV
Feeders fed by three ±2,500 kVA Transformers• The equipment on-site was designed to support up to ±22 MW. Based on
demand, PG&E can investigate the potential of delivering additional power beyond the current allocation to the building
COOLING• ±1,836 tons of cooling from air-cooled chilling plants supplying internal computer
room air conditioning units (CRAC units)
SECONDARY (EMERGENCY) POWER• Approximately ±7,500 kVA of Generator power via three (3) ±2,500 kVA standby
diesel generators
FIRE PROTECTION• Protected by a dry-pipe pre-action fire sprinkler system
TELECOMMUNICATIONS• Fiber Rich Area: Primary network communications from Level3 and CenturyLink• Landlord has pending access agreements with AT&T, Comcast and Integra to
provide additional connectivity to the building
RELATED FEATURES• Exterior electrical and mechanical yards: Site contains attached and detached
mechanical and electrical equipment support yards. No overhead or roof-mounted air conditioning equipment (with the exception of two package units for 1360’s main electrical room), supporting disaster and reliability planning.
Electrical SystemComponent
ComponentCapacity
InstalledQty
InstalledCapacity
UsableCapacity
Transformers ± 2,500 kVA 3 ± 7,500 kVA ± 7,500 kVAGenerators ±2,500 kVA 3 ± 7,500 kVA ± 7,500 kVAUPS ± 625 kVA 7 ± 4,375 kVA ± 4,375 kVAPDUs ± 200 kVA 15 ± 3,000 kVA ± 3,000 kVA
Electrical SystemComponent
ComponentCapacity
InstalledQty
InstalledCapacity
UsableCapacity
Air Cooled Chillers ± 459 tons 4 Units ± 1,836 tonsData Center CRAC Units
± 20 tons 44 Units ± 880 tons ± 2.5 MW
ELETRICAL SYSTEM SPECIFICATIONS
MECHANICAL SYSTEM SPECIFICATIONS
1360 KIFER ROADSUNNYVALE, CA | ±56,773 SF AVAVILABE FOR LEASE
DATA CENTER | LAB | MANUFACTURING
Metro Network
• AT&T• CenturyLink Metro• CenturyLink Metro Leased• Comcast• Electric Lightware (Integra)• Integra• level 3 (TWT)• Level3 Metro• M Power
• Silicon Valley Fiber• Sunesys• Telepacific• Vest Networks• Wilcon - Dark• XO Communications• Zayo Dark• Zayo Metro• Zayo Planned Routes
Long Haul Network
• CenturyLink Long Haul• Electric Lightware Long Haul• Level 3 Long Haul• Sprint Long Haul• XO Long Haul
Building Service Provicers
• AT&T• Comcast• Integra• Level 3• Qwest/CenturyLink
1360Kifer
MetroNetworks
LongHaulNetworks
CenturyLinkMetro
CenturyLinkMetroLeased
ElectricLightwave(Integra)
Integra
Level3(TWT)
Level3Metro
MPower
Paxio
SiliconValleyFiber
Sunesys
Telepacific
VastNetworks
Wilcon-Dark
XOCommunications
ZayoDark
ZayoMetro
ZayoPlannedRoutes
CenturyLinkLongHaul
ElectricLightwaveLongH…
Level3LongHaul
SprintLongHaul
XOLongHaul
PlusAdditionalCarriers...100m
500ft |Bing,©2010NAVTEQ,©AND,©2016MicrosoftCorporation
15 NETWORKS IN
NEIGHBORHOOD
5 NETWORK (POP)
IN BUILDING
1360 KIFER ROADSUNNYVALE, CA | ±56,773 SF AVAVILABE FOR LEASE
DATA CENTER | LAB | MANUFACTURING
Floor Plan
Site Plan
AVAILABLE
MEETMEROOM
ELECTRICAL
TRANSFORMER
RISER(S)
COMMUNICATION CONDUIT
GRADE LEVEL
DOCK HIGH
SHARE AREA
GENERATORYARD
MECHANICALYARD
ELECTRIC
AL
CR
R
R
T
T1
T2 T3
C3C4
C2
C1
WAREHOUSE
LEASED
±56,773 SF AVAILABLE
© 2016 CBRE, Inc. This information has been obtained from sources believed reliable. We have not verified it and make no guarantee, warranty or representation about it. Any projections, opinions, assumptions or estimates used are for example only and do not represent the current or future performance of the property. You and your advisors should conduct a careful, independent investigation of the property to determine to your satisfaction the suitability of the property for your needs. Photos herein are the property of their respective owners and use of these images without the express written consent of the owner is prohibited. CBRE and the CBRE logo are service marks of CBRE, Inc. and/or its affiliated or related companies in the United States and other countries. All other marks displayed on this document are the property of their respective owners.
1360 KIFER ROADSUNNYVALE, CALIFORNIA
Please Contact:
JERRY INGUAGIATOSenior Vice President+1 408 453 7462 [email protected] Lic. 01213889
PAUL SCHMIDTFirst Vice President+1 408 453 [email protected]. 01312645
MICHAEL COLEClient Services Coordinator+1 408 453 [email protected]
CASEY PILEGGI Senior Leasing Director +1 408 453 [email protected]
Lawrence Caltrain Station